Loading...
EPA-NOI-Plan-6-3-19.pdf12" CMP Jerome P. Camposeo Susan M. Camposeo Book 6240, Page 106 Plan Book 226, Pg 7 Parcel 2 Assessors Parcel # 08-070-001 160,740 s.f. +/- 3.690 ac. [to be reduced to 156,107 s.f. 3.58 ac by 9' strip to be conveyed] N/F MARK A. REJNIAK & DAVID E. REJNIAK BOOK 1164 PAGE 148 BOOK 7909 PAGE 180 N/F DENNIS P. GRIFFIN BOOK 3214 PAGE 329 BOOK 8253 PAGE 334 PLANBOOK 35 PAGE 34 N/F CITY OF NORTHAMPTON BOOK 12654 PAGE 99 N/F CHUONG Q DINH & QUYNH N. DINH BOOK 10715 PAGE 222 N/F CHERYL PASCUCCI THOMAS PASCUCCI BOOK 12135 PAGE 55 re s e r v e 1 2 3 4 5 6 House 2 car Garage 10' mi n . Onsite well (owner's option) 105' 105'106' 107' 108' 109' 104'110' 111' 112' 113' 114' 115' 116' 117' 118' 119' 120' 104'103'102'101'100' 99'98' 105' 104' 103'102' 101' 100' 101' 99'99' 99' 1 1 0 ' 11 1 ' 11 2 ' 11 1 ' 11 3 ' 1 0 9 ' 1 0 8 ' 1 0 7 ' S63° 1 1 ' 1 3 " E 229. 2 0 ' S66° 5 1 ' 4 0 " E N0 4 ° 4 2 ' 3 8 " E 16 2 . 0 0 ' 258.7 0 ' 48 . 0 0 ' 10 0 ' 50 ' wetland disturbance 1,518 s.f. 113 113 113 113 6" Sched 60PVC (or ductile iron) ProtectivePipe sleeve on 4" bed of aggregate 113 112 wetland disturbance 666 s.f. wetland disturbance 2,222 s.f. silkydogwood (typ.) separation 8-10' o.c.see detail p. 3 Wetland replication 4,406 s.f. +/- 5R 6R SC-160 flow equalization devices (see detail) TBM top of Hyd. @ 108.20' (assumed datum) N TBM # 2 nail in tree @ 119.73' (assumed dautm) TBM # 3 nail in tree @ 108.01' (assumed dautm) TBM # 5 nail in oak @ 105.32' (assumed dautm) TBM # 4 nail in tree @ 105.92' (assumed dautm) TBM # 1 nail in tree @ 105.95' (assumed dautm) vegetated wetland WATER SERVICE(by others) 0 30 60Graphic Scale 1" = 30' vehicle turnout In accordance with 250 CMR 5.03 (13), the affixed professional engineers seal MA 43298 applies to driveway, drainage and wetland replication design only. All other design is excluded. utility pole (existing) Plan symbols wetland flag iron pin reported by land surveyor iron pin or iron pipe found utility pole (proposed) concrete slope reinforcement block silt fence soil boring Wetland and Buffer Zone Areas Calculations: Total area of wetland on property - 59,500 s.f. Total area of permanent wetland disturbance - 4,406 s.f. (7.4% ) Proposed wetland replication area - 4,406 s.f. Total area of 0- 50' buffer zone on property - 32,360 s.f. Total disturbance of 0-50' buffer zone (for driveway) - 5,028 s.f. (15.5 % of 0-50 buffer zone on property) Total area of 50' - 100' buffer zone on property - 30,026 s.f. Total disturbance of 50' - 100' buffer zone for driveway 2,496 s.f. (8.3% of 50-100 foot buffer zone on property) Plan Notes: - Wetland delineations, topography, septic design, and wetland replication prepared by Environmental Planning Associates. - Vegetated wetland southeast of subject parcel 08-070-001, flagged on the ground (W1 through W6) and surveyed by Environmental Planning Associates in August, 2018 Construction Notes: - This Plan is not valid for construction until approved by the City of Northampton Conservation Commission and MA DEP. - Wetland replication area work pursuant to C-C' XC on p. 3 Wetland Replication Plan Narrative submitted as separate document with Notice of Intent. - In temporary disturbance areas inside of silt fence, remove any fallen debris, restore to original grade, hand rake, plant wetland seed mix in temporarily disturbed wetland and conventional grass seed in temporarily disturbed upland; cover with straw upon completion of construction work. 5 0 ' W1 W2 W3 W4 W5 W6 1 0 0 ' buildin g setba c k build i n g set b a c k S24 ° 3 7 ' 4 0 " W 197 . 2 5 ' N1 2 ° 3 9 ' 1 2 " E 20 9 . 9 5 ' S40 ° 5 1 ' 2 9 " W 136 . 5 9 ' S38 ° 1 4 ' 4 5 " W 261 . 9 2 ' N68° 3 3 ' 0 1 " W 172.0 7 ' N63 ° 0 3 ' 0 3 " W 324. 6 0 ' 239. 2 7 ' 25 7 . 9 5 ' S38°01'26"W 26.93' N67° 2 1 ' 0 8 " W 15.91 ' 497.9 7 ' TOT A L N65° 2 2 ' 2 0 " W 422. 5 0 ' Site Locus Map WF 2WF 1 WF 35 WF 34 WF 4 WF 5 WF 3 WF 6 WF 7 WF 8 WF 9 WF 10 WF 11 WF 12 WF 13 WF 14 WF 15 WF 16 WF 17 WF 33 WF 32 WF 31 WF 30 WF 29 WF 28 WF 27 WF 26 WF 25 WF 24 WF 23 WF 22 WF 21 WF 20 WF 19WF 18 WF 9A we t l a n d b o u n d a r y wetland boundary pp 38#39 pp 37#38 9' wide strip to be conveyed to City of Northampton Co l e s M e a d o w R o a d Assessors Parcel # 08-004-001 Chuong Q. Dinh Dated: 3/25/19 Rev. : 6/3/19 Scale 1" = 30' Drawn By: PRL Checked: GLC Residential Development Plan Jerome and Susan Camposeo Assessors Parcel # 08-070-001 Coles Meadow Road Northampton, MA Page 1 of 3 Plan View P.O. Box 351 South Deerfield, MA 01373-0351 (413) 665-7903 (866) 318-2770 (fax) Environmental Planning Associates Environmental Planning Associates © 2019, All Rights Reserved Costa Consulting Engineers, Inc. 104 Moody Street Ludlow, MA 01056 Coles Meadow Road Northampton, MA FILE NO: FIGURE NO. MADE BY : GLC DATE: 3/25/19 REV. : DATE: 6/3/19 CH'KD : GLC DATE: 101 ' B 105 ' 104 ' 103 ' 102 ' 106 . 4 5 106 . 9 5 106 . 9 8 104 . 1 5 101 ' INV. 104. 0 INV. 103. 0 INV. 103. 0 106 ' 100 . 0 101 . 8 3 100 . 0 INV. 98.5 INV. 98.0 0+00 New 1500 gal Single Compartment Septic Tank Septic soil absorption system A A ' INV . 104.0 vehicle turnout 102 ' INV. 98.5 INV. 98.098' MASSDOT M2.02.4 (typ) SC-310 culvert (see detail) B ' B 104' C C' 101 ' 100 ' 103' 102' 101 ' 99'