Loading...
24B_038RR 327 King St Plan Summary,n ~ ~) ~ ~`i To: City of Northampton From: Brian J. Allen Agent for Pocket Wireless Re: SPMA0050 327 King Street, SPMA0051 22 Atwood Drive, SPMA0052 Westhampton Road, Northampton Landfill Dear Planning board, Pocket Wireless is looking to provide wireless phone service in and around the City of Northampton. Below is a quick summary of our plans • Pocket is a new provider in Northampton and as of yet we do not provide service • It is necessary for us to have a number of Wireless sites in the City to provide service. • It is Pocket's desired to co locate on existing towers in an around Northampton and to supplement that with rooftop installations. Currently we do not have plans to build additional towers in Northampton. • Pocket typically flush mounts its antennas directly to the towers as opposed to using triangular boom mounts, this minimalistic approach allows more carriers to use existing towers • The attached maps show our current plan of sites in and around the City of Northampton. It is our hope that we would be able to lease these facilities as well as obtain the necessary permits to install our equipment. Currently these are the only sites that are proposed for the area, we anticipate having acceptable coverage with the sites depicted. • We look forward to providing excellent coverage and customer service all who live, ,work and travel through the City of Northampton. For the purpose of this application we have provided the following: • A letter from CSquared Systems regarding our licenses and our compliance with FCC regulations as requested in section 350- 10.9.C.4 • Coverage Maps and network Maps as requested • Plans of the proposed modifications to the existing towers Baia ~ J Allen KJK fireless Agent for Pocket Wireless 3 Brookside Drive Sutton, MA 01590 508.868.0927 briars cr,kjkwireless.coin L,J ,:, J~N>~ ~ 8, 2~0~g i ~~-CITY CLEf~KS~,O F -~ G N RI~-PM~~~1)`~ o A ~~ 1 File # MP-2009-0033 APPLICANTlCONTACTPERSON KJK WIRELESS ADDRESS/PHONE 127 RIDGE RD {G03) $21-IS11 {} PROPERTY LOCATION 327 KING MAP 24B PARCEL 038 000 ZONE (~~i - ~~~ ./-~ 1 J,~ ~~ ~ ~ ~ .~~ THIS SECTION FOR OFFICIAL USE ONLY:~1 j PERMIT APPLICATION CHECKLIST __~__._,..,~ ~ ENCLOSED REQUIRED DATE Building Pernt Filled out Fee Paid T eo,~f Construction: ZPA -INSTALL 3 ANTENNAS & G COAXIAL CABLES ON E3~STING TOWER & G X 10 CONCRETE PAD FOR EQUIP New Construction Nan Structural interior renovations Addition to Existing Accessory Structure Buildine Plans Included: Ownerl Statement or License 3 sets of Plans /Flat Plan THE FOLLOWING ACTIOlN~HAS SEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESE ED: Approved dditional permits required (see below} PLANP1IPiG BOARD BERM/IT REQUIRED UNDER : § ~~ Fl'I~' • ~ ~ I L ~ `~ ~ ~ ~ Intermediate Project : / Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIltED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DFW Water Availability Sewer Availability Septic Approval Board of Health Permit from Conservation Commission Well Water Potability Board of Health Permit from C13 Architecture Comrnittee Permit from Elm Street Co n Permit DPW Storm Water Management ----~~- ~ Signature ofBuilding Offs " ~ ~ Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with ail zoning requirements and obtain all required permits from Board ofHealth, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact the Office of Planning & Development for more information. ~'~ ~~ Page 1 of 5 (` ~ 1 Brian J. Allen From: form engine@fs12.formsite.com on behalf of wfeiden@northamptonma.gov [form engine@fs12.formsite.com] Sent: Monday, December 08, 2008 9:57 AM To: Brian@kjkwireless.com Subject: Planning Board and Zoning Board Application Form Results Follow Up Flag: Follow up Flag Status: Red Planning Board and Zoning Board Application Planning and Zoning Boards Owner First Name * Owner Last Name OR Business Name Colvest/Northampton * Owner Address 360 Bloomfield Ave Sutie 208 * City Windsor * State Connecticut * Zip Code 06095 '-? Applicant First Name Brian * Applicant Last Name Allen Business (if applicable): Agent fox Pocket Wireless * Applicant Street Address 3 Brookside Drive * City Sutton * State Massachusetts * Zip Code 01590 * Phone !3 508.868.0927 * Email 1/5/2009 ° ~ "~ ~ ~. Page 2 of 5 ,~ ,, brian@lglcwireless.com * Assessors' Map(s) and Parcel ID(s) 24B-038 * Parcel Deed Book and Page 5036 pg 91 * Work Location 327 King Street * Post Office for property Northampton 01060 * Zoning/Overlay Districts HB * What PERMITS ox AMENDMENTS are you applying for? PLANNING Special Permit w/ INTERMEDIATE Site Plan ($200, except flag lots $1,000) PLANNING Special Permit w/MAJOR Site Plan ($1,000 plus, unless this is an amendment, $0.05/sq ft of proposed new building) ^X PLANNING Intermediate Site Plan ($200) PLANNING Major Site Plan Approval ($1,000 plus, unless this is an amendment, $0.05/sq ft of proposed new building) APPROVAL NOT REQUIRED Surveys ($250/plan page) PRELIMINARY SUBDIVISION ($1,000-Type II or $G00-Type I PLUS $75 per unit) DEFINITIVE SUBDIVISION (Greater of $3,000 OR $10/linear foot of new roadway; $4,600 OR $14/foot if no preliminary; $400 PLUS $10/foot for one lot minor subdivisions; $500 for Amendments) ZONING BOARD Special Permit ($200) ZONING FINDING ($200) APPEAL OF BUILDING COMMISSIONER-Zoning ($200) COMPREHENSIVE 40B PERMIT ($500 plus $0.05/sq ft of proposed new building) VARIANCE ($1,000 plus $0.05/sq ft of proposed new building) 43D Permit (Any Planned Village commercial project) * Relevant sections of zoning and subdivision regulations 350 AH.1,10.9,11 * Describe project and relief/approvals needed Colocation on existing tower, adding equipment at the base discussed my application with my neighbors (highly recommended) '' ~ I HAVE Finding Request * How does the project meet the Finding criteria? The existing property, use, or building is legally preexisting nonconforming The project does NOT create a new zoning violation The project is NOT more detrimental to the neighborhood than the old use * Describe in detail how you meet the Finding Criteria 1/5/2009 ~'~ ~ ~ Page 3 of 5 N ~ I ~ .. Appeal of Building Commissioner Action * Are you claiming: The Building Commissioner erred in a zoning related matter A UNIQUE injury as a result of such error that meets the standing test * Explain in detail l) What the alleged zoning error the Building Commissioner made and 2) What is the unique injury YOU suffer from the alleged error? Comprehensive 40B Permit * Check all that apply for your 40B project We are not requesting any waivers We are requesting Zoning waivers We are requesting Subdivision waivers We are requesting waivers of other local rules Attached is our Site Eligibility Letter Attached is our Draft Affordability Agreement Attached is our Financial Proforma in compliance with 40B * Explain WHAT waivers axe you requesting, WHY, and HOW could you AVOID them? Variance Criteria * I meet the following Variance Criteria There are UNIQUE circumstances that effect ONLY this property/structure and not other properties in the neighborhood A literal enforcement of the zoning would create a HARDSHIP, financial or otherwise If denied there would be NO reasonable use of the property The hardship is NOT self-imposed Relief can be granted without detriment to the public good The variance would not substantially derogate from the intent of the zoning The request is for the SMALLEST relief possible * You must document how you meet ALL of the Variance criteria. Special Permit and Site Plan Criteria * Will the project ' r ^X PROTECT adjoining premises from seriously detrimental uses t * How z ' applicant is proposing co-location on existing tower- will not be expanding the premises * Will the project 1/5/2009 " ~~ i~~: Page 4 of 5 X^ MITIGATE and MINIMIZE traffic impacts * How Applicant is proposing a co-location on existing tower tiffs is an unmanned site * Will the project ~X PROMOTE a harmonious relationship of structures and open space * How Applicant is proposing a co-location on existing tower, no additional structure will be needed ', * Will the project PROTECT the general welfare * How Applicant is proposing a co-location on existing tower, no additional towers are proposed * Will the project AVOID OVERLOADING and MITIGATE Ciry resources * How Un manned site will not require additional city services * Will the project ^X PROMOTE and NOT HARM City planning objectives -' * How i Applicant is proposing coloration wich is in harmony with city objectives ~~' * Will the project ^X Meet all zoning requirements * How applicamt is proposing coloration on an existing tower the facility will comply with all zoning requirements Which preferred methods of improved circulation are used Project minimizes curb cuts Project only uses one curb cut ^X Project uses a common driveway or shared service road for access Project uses an existing side street Project uses extra measures to reduce parking need Project separates vehicular traffic from bicycle and pedestrian traffic Project is requesting a reduction in required parking spaces as follows: * Describe how meet the improved circulation goals (above) and how you reduce curb cuts and parking demand. this is an unmanned site I understand that traffic mitigation does NOT replace the need to ensure safe traffic circulation to the site from surrounding streets and nearby intersections * How does project mitigate all traffic impacts? ~X I am providing justification that there will be no increase in traffic from the project; OR I am mitigating ALL off-site incremental traffic ANYWHERE from the project; OR In lieu of studying and mitigating ALL off-site incremental traffic, I am proposing $2,000 in-lieu of fee per peak hour vehicle trip ($1,000 fox projects widen 1/2 mile of downtown or Florence Center) 1/5/2009 ~ /~ Page 5 of 5 ~., ~ i i * MAJOR PROJECTS: This project mitigates stormwater impacts by: All catch basins and manholes have 4' sumps All runoff from a 0.4 inch rainstorm (first flush) will be detained fox an average of 6 hours No increase from PRE to POST-development peak flow during 1, 2, or 10 year NRCS design storm The impacts are otherwise mitigated (explain) DPW has issued a stormwater permit for the project ` * I REQUEST a WAIVER from these Site Plan filing requirements (describe why below) X^ 1. Site Plan at 1" = 40' or greater 2. Name and address of the owner and developer, name of project, and date ^X 3. Existing and proposed buildings, property line setbacks, building elevations, exterior entrances/exits 4. Present and proposed use of the land and buildings ^X 5. Existing and proposed topography using 2' contours ^X 6. Wetlands, streams, water bodies, drainage swales, wetlands, unique land features 7. Location of parking and loading, public and private ways, driveways and walkways, access and egress points, proposed surfacing 8. Location and details of all stormwater drainage, detention and water quality facilities, public and private utilities and easements, sewage disposal facilities, water supply facilities 9. Existing and proposed landscaping, trees, plantings, stone walls, buffers, and fencing 10. Existing and proposed signs locations, dimensions, and details ^X 11. Provisions for refuse removal and screening 12. Lighting/Photometric Plan (maximum 0.5 foot candles at property boundary) 13. Erosion control plan (MAJOR projects only) 14. Traffic Study (MAJOR projects only) 15. stormwater Management Plan AND Drainage Calculations(MAJOR projects only) 16. Plans stamped by Professional Engineer (Dewberry Goodkind Greg Nawxotzki) ~ Add time and place of heating as soon as it is available ^X I have ALREADY posted the REQUIRED sign so it is visible from a public way http: / /tin}vrl. com /23mo~t ANR Applications must include the following in order to be processed: 1. A box located on the lower right of each plan showing the following: A. Approval Not Required signature block B. A note that "Planning Board Endorsement is not a determination that the lots shown are buildable lots" C. A list of all parcels shown on the.plan with a correspondence table to Northampton Assessors Parcel ID 2. An electronic copy of the survey in AutoCAD 2000 format with all parcels closing to an accuracy of 1 in 25,000 3. Control points when required by the Northampton Subdivision Regulations. http:/h~-~~-w.northamptonma.gov/opd/Abutters%5FLists%5FO1d°/nSFPermits%SFHistoric%SFlncentories/ A 43D project (applies to any project with a commercial or industrial component within the Planned Village District) guarantees that most applications for city permits will be processed witltin 180 days. To take advantage of dtis: 1. You must apply for all xelvent pertnits at the same time at the start of the process. 2. The time clock does not start until the City has deternvned that the permit applications are complete. Contact Carolyn Misch, Permt Manager/Senior Planner, Office of Planning and Development, for details. 1/5/2009 (~ Systems Northampton Town Hall 210 Main Street Northampton, MA 01060 December 29, 2008 %~ ~~ ~ 920 Candia Road Manchester, NH 03109 (603) 657-9702 RE: Pocket Application for Sites SPMA0050, SPMA0051, & SPMA0052 Dear Board Members: Youghiogheny Communications LLC, (herein referred to as Pocket) has been licensed by the Federal Communications Commission (FCC) to provide Personal Communications Service (PCS) within the Springfield-Holyoke BTA. Pocket is currently in the process of building its wireless communications network throughout western Massachusetts. This build-out process is currently underway in Northampton, Massachusetts. Pocket is licensed to operate under Call Sign WQGA725. In order to retain its FCC license, Pocket must meet all Federal, State and Local requirements regarding transmission and radio frequency interference and adhere to the rules outlined in Title 47 of the Code of Federal Regulations (CFR), Part 27 regarding the Advanced Wireless Services (AWS) Spectnun. In addition to the above Pocket must meet the radio frequency emissions standards for Maximum Pemussible Exposure (N1I'E) as set forth in ANSI/IEEE Std. C95.3, ANSI/IEE Std. C95.1 and FCC OET Bulletin 65 Edition 97-01. ~~ ~` - C Squared Systems, LLC .. .. -- ,. o ~.. .. ,. .. ,. .. .. .. • ~. ~ _.__.. ,: ,.._..~ 1 .... o ~ ~..,,. ; rr , d ;' 0 ou ~ _... ~ C7 '_' - ~ ~~ ~ i a a ~ ~. ,. ~ _..fA 1~-s- ~ ,.....-. ~; /1 y i -- ~ ~.~ ^_--- ~ J / ~ .... ~.,. ..... ~' i % i ; ~-~ •. -._" _ -- _. r _. '~ ~ ~; ...__. ~ 5 ' 1 ~.. -._. ,, . 3 O ,.....,.;.}..., . II ,~ _~ i •~ ~ ~~ z -- .__ `' ....... ,,..•" ,. -i ,,.1 ~ - _...~ -' - 8159 // ~, N ,-- ~ ~ . ;ter--,a--~` ~.~^'~ .~ n _ .... ' -- ,a I :.. _ .~ ,- . ...... .. . / i i o ~ _ _ _ _ --- _:_ - . ;. ~~ .; - _ N `'~~ ', ._~_. - .~., . , , -.. ... - ~'~~ 1 ;, i_C..._. ~ , ~', l ,' `• ._... t '~. . .~ :,...., 1 ,. .. -, , - ;~ .-.... ` _ ~....~ 4 •`\ .... ~ ., ,.. ,~.`. ^, l N ~. _ ,~ ~ ~ o ,~, ._.. ';:. .. . _. ~ / .. _.,. ~ - .. ~-•- i / / ~ ..-. _ ~ :,, h~ , ,. _ ~•.~• _ .. • .: ..,.: ., .., - ... ,. ,.. ;. _. ... ~.. - T / .~ ,. ~~~ ,. - r ~ ~_. -...\ P ~ ~_ ~\... ~` .....'. Cp. /'~ ~. '\ ..:,,. ;:.. ... , ,.;;;. i O~ ., ~ ., ,.. ~. ...%_ 7 <.._ `' ..; i. .. _....._ ;` r -- 1, .. ,. ,:. ,..~ ~~ -, . . ~.. I _ ,... tir ~ ~ - r .' -~ ~ . ,y ~~ ~ ~ . ,•. ~ ,.'1 ., ~~ :, :~ .. .. .~ .... ; : . -'" ;' .; ~` ~ _ _ ,: ,. „, ,_ ; , <- ° to .*r ...:,~ •; ' ' ~ `< . ( Y ~., .,' i ~~ i ~ D i ,~ .~ ': l Vii: ~ V ~ ~ ,, . .. .. . . .. _. - - ~"T ~..-~ ~ . ~ ~.J.N.__-,-. .. ~ - ^~~ • .~ ...... -- ~ '- _. ~ ., _. .. _~. - ~ ~~ - ,~ IC.~.. :.. ~ ~ - -- --; ~ --- .... ; - ,... _ ~ i ~ ~ ~ 'G .- ... ~ / .. -' .. ;` '~. . ~~ ~. ,,~, ~,' ~ v ~ _ ,. o _ : -~ - i ---- - • ~ _y ~~ .; ~ ~ .. - . ~. ,.._•. .., 5 ~ V _ t ~ C `~ -~_, `' .. ~ -~~ ..- ~ .. ~ ' _~ _ j "~ ~ i. ~J ..., ~ r i I -~. ~-- ' ~ F _ " ~ ~'r,.~ X11 '~ "~ rr a r l k~~~~.~ F Z'.y 4~ ~ 1 ,yj,~` L^k' )F Bch ~' ~i v ~ ~. rr •_ X ~ F-x.. u ..~~ 1 ~ ~ ~ ! ~. ~ ~ +'1° 1.~'-' tt-Jr~ , r , ~° ~ t ~V., e 1`l~r ~~~ f ~ `V~ }~ x~ .~• ',} o `.i' } .yam„ 'dW' ~ .^(r ~ ~~ ~ I Zia 14,~ t GGzz __-- r'- ~ ~ _ Q w_ a e 1% ~ ~~ ~ L~ ~ ,: `~ :~ r ~ ~, a r )~ ° ' ' ' y ~ n . ~ ,:~ ~ r t O 0 ' 1 RI. ~ `~' " . ~ ' J '~ ~ + .~ ~ \\ `~~ r~a~ ~ fA ~ U o ~ ~r1 .l. '` V ~~ `~' di ~o ~ ~ Z ~ ~ ,~n , ry~~~~ ~~ r w .:'S. ~+ I.i y r.-i:. 1c ~ .G L 1 ..fir P' ' ~ ~'r~ ;.._ &`~' ~ , ~~ ~ ; ~a ' ~~. ~ w~ C/~ ~ ~' "~~ '~ fir. "' ' ~ `F,`t 1, ~ ~ y ~ ~ . it ; f~ .,~ ' ~ , 4~ ... ~ ~ ~ tn~ _ ~~ a j ` ~ ~ ~ ~~ rC-'- ~b~'~ ),~iS~a?Y ~ ~. ,_ ` P-i ~ ~ ~~° r ~ ~ ,~ ~, ~- -_. ~ r_ ~s R !1~ 'w` 'O ° ° ~ ~ r '' Q ;; r=~ a ~~ ~ ~ m' C~' s a , , d'~ ~ ~~T' f C~ ~ '~~~~ ~ ~. ~~ ~ - <-~. to ~ ,. r ~_ ' ", ~ ,, } ~~ \~:u ;hey br ~ ~ F~ ~. S ~ Cr ~~'.vi ~ ,: d `i i V ~ _, ~~ L~.,7 y~ ~ tr ~ ~ ' `_~ ~ _. ,tic ~'~' :~'4' d h ~`~' v~ ~,~~ r ,r F ` a~ ~ ~~ ~~ 4, 5,~~ ~'Sf }ln.~c' 5 ~ cnv- VS M~ ~uQ c u, ,. yJ~p \ 4 F ti y ~~ ~ ~ ~' r ~ r=~ ,~, ~~~ 1 n t t .. ~ i ~ r,` r ~~ ~~ r ~ t ~+ ~ m i /' 3 ~/ ,~ { ~.. i ti ~"~ 1 ,°' J ~ +~ ~) 7~ -~ aG ~ Q ~,~ ~ ~ ,~ "rs.... t ~ ~~ t 'a - r ~ r ~ d, r-- ~ ~~'~ ~~ r ,1 ~ 'at~C ~W b~ y~~t ~_ ~ W ~~_ ~ ~ r ~, ~~, pty4. -, fl is ~1; - ? ems. ~'~` ~~ r' . ~ (~~~ il ~ 1 / R.~#` ~ 7 ~~ t ~' N ~ iz i r ~y ~~ i ~ ~ ~~ 3-i~r ~~~ r F" ~ d t A . ~ 7 ~d ~ r V ~; ~ ? .V t ~ d y ,~ ,K"'r ~ ~ k.~~ rtt3r.~ Y' fir ~ S n... ~fcL~ .u-4n1. '~ L , ~ t 1Y A } ~~ ~ ~ ~~ i t+ te< "$' ~~ ~ ~ b um~ . L k.. ., ,~ ¢ ,_ q i r nr o ~'~ ~~, , r~ ~sy~ i _ ~ ~: Rte` ~ ,> I 45' ~Zy 1 ' .YZ"'^~3 ua ~ :r ti r, ~ `~0 ~.. ~~~ ~~"~,~ E~I~ ~~ '~i ~F ~r~ - ~ . ~ ~ u: ~ `~ 'u~M ~ cgi~ ~i` ~ ~ ti" .^ `~ . P -~z. _. ~ _ ... O ~~ Z ~; '.., .tip ! S 7 .Q 1 -- ;' .~ ~ ~: - y~ ~~ ~ ~ , ~~ Y4 ~ _ , _ W ~_ _"' '~'~ '~" ~~ ~ ~~ - "`-, -- -~~> i ~ mod. -~ ~ ~, ~, ~ ~~ r~~~~ ~w i ,~ ~._ ~ l"°r ~, i 4, ~~ ~ . 0 ~pp bA ~ ~? Q ~ -~ -~ 0 ~~ a W G ~- -P O r Y f 1(j O n ~ , a ~ C ' a ~ ~ ~' 1 n~ ,' . ~ -,:~ ~ ~~ O ~ ~!- O ,.' 1 ~~ ~~ •~ ; o bA }, !Y~'fi"'''' r~ - ~ y r > '/ ~ ~ ~ iJ ~ Y ~' ~ ^a %~-,---\ r . . u~ 1 ~ ^~~ :~3~'$ t . r ~~~ Y t r~ ^ ak ~ ~ 4 t '~ ,"~,~ 'ms's ~ _ I 7 N. ~ `~ / L i ~ d E ~~ ! r ~ n t, ~ ~,~'. a 1 4 .,tr ~ : r ~ J ~ ~ ~ ~ ~ x ~ N 5 + ii ' ~ ~ ; ~ ~' , wr ~1 ^ VS .sz = eI ~ ~ Y~~ ~J ~ v +.~ ' .a ti~ ~ ~ ~ ~.t" ' }~ ~.• ~` ~- ~ _. ,_ . ,~~ „ y :.,r d .t r?'~ ~ " I h ` ~ ~ ~O .o N 7-i ~;: ~~'t ~s~ si ~ .',. ~ ,. N '~ ~ Si ~` 7Y t ~ ;~ ~ ~\ ~ ~ v U ~Y, , ,~. U '+. 1 r ~ at~"'r+"' t'' ~,~~} ~`~ ~.f ~ r! C~.r ~ r'h;~ww, r. r > N pQ ~~' ~I '^ \ \ . 1 w., 1 ~~ ~ { -' m " ~ '~ ~ r=~ v6' ~" .a1 i~~ n . ~,,`~ 5 4,~ 164rS~y}+~~~7., ?,,i jj,~ gyp`, ~~"e• ~ z. i ~ ~'' a ~~ ~~ f ~a f ~~'~ <~,~ F~ a r ~ o ~~~ ~~ - u ~`7 R~~'~ti ~ _ I.r;:, rte' ~i 1,,; WI 4 ~ ~ . 2 ; ,~ x ~ ~. : ; is ~'tl`~ d~ia~i~ j ~~ ,. 1 a,F ~ ~v ~d ~ ~ ~, y ~ J o ~: F -fir ~ ~ ~ .. ~5`J~ ~ ~ ~ t ~, ~ tom' ~ ~ ~~Wi; ~•• w .~ ~r z ~ ~ -- r ,~, ~ ~ i'•, t ~, ,, ~ ~~- ~ ~ year r' ~. ' ~ ~ --~'r~_ 4-' •' , i •- _ O j & ~' ~ „ ~~i rR r ~ ~~ .~' -' r~ V ~ g+"~~ • r~ ~ ~ -_ _ ~;~ ~ a ~ ~ ~ ~'~ ~ i.i E 1 ~ -~ O ~ ~ -// ~ iii ~ \~` __-.. .. Z N r' c~ ~ "`s" ~ i M ` ~~ ~ .. dy .~'i i°lnNn ::co ~ QYZ •'U~ i _._... _.. __ ~c lA M J ~ R> C7 ~ _ __.__ ~. c'3 ra S ~ 1 ~ n 'tit ~ (",. ` ~ , y W 'if " t ~ ' ` .n~~~ ~ !L ~ ... "f ~y '~~ N ~ cn _ ~_ ~~ ~~. ~ ~n ~ ^~ ~ Q ~ p ~ ~ O ^~ ~ ~ W ~ _ _, ~~ ~~ ~. SITE ADDRESS: TOWER OWNER: LATITUDE: LONGITUDE: ELEVATION: JURISDICTION: CURRENT USE: PROPOSED USE: UTILITIES POWER: TELCO: PROJEI~ ~` INFORMATION RF REVISION #: RF REVISION DATE: 327 KING STREET NORTHAMPTON; MA OTO60 AMERICAN TOWER 116 HUNTINGTON AVENUE 11TH FLOOR BOSTON, MA 02116 42' 20' 4.19" N (NAD 83)* 72' 38' 1.58" W (NAD 83)* *PER AMERICAN TOWER 160' (A.G.L.) TO ANTENNA C.L. CITY OF NORTHAMPTON TELECOMMUNICATIONS FACILITY TELECOMMUNICATIONS FACILITY NATIONAL GRID VERIZON RF REVISION DATE (B00) 322-3223 (eoo) s41-ssoo SITE ADDRESS: SITE ID: PK~: METER#: AFTER HOURS: SITE NUMBER: SPMA0050 SITE NAME: 327 KING STREET VICINITY MAP APPLICABLE BUILDING CODES AND STANDARDS DIRECTIONS: TAKE US-3 SOUTH. TAKE RIGHT FORK ONTO 31-30B-A TOWARD MARLBORO 'I-495)/LAWRENCE/CHELMSFORD (RT-110). TAKE EXIT 30B/MARLBORO ONTO I-495 SOUTH. TAKE EXIT 296/LEOMINSTER ONTO RT-2 WEST. CONTINUE ON RT-2. TAKE LEFT RAMP ONTO I-91 SOUTH TOWARD RT-2 W/SPRINGFIELD/NORTH ADAMS. TAKE EXIT 20/NORTHAMPTON (RT-9)/HADLEY ONTO N KING ST (US-5). THE SITE WILL BE ON THE LEFT. DRAWING INDEX REV SPMA0050-T01 TITLE SHEET' 0 SPMA0050-G01 GENERAL NOTES & ANTENNA B.O.M. 0 SPMA0050-A01 PROPOSED SITE PLAN & ELEVATION O SPMA0050-C01 CONSTRUCTION DETAILS O SPMA0050-E01 ELECTRICAL RISER DIAGRAM & BTS 3231 DETAIL 0 SPMAOOSD-E02 SCHEMATIC GROUNDING PLANS O SPMA0050-E03 GROUNDING DETAILS 0 NOTE CONSTRUCTION ON THIS.SITE CANNOT COMMENCE UNTIL THE RESPECTIVE DEPARTMENTS HAVE APPROVED AND SIGNED THE DRAWINGS. REAL ESTATE RF OPS/CONSTRUCTION LEGAL/COMPLIANCE NE7 DESIGN STRUCTURAL REVIEW CONTRACTOR SHALL OBTAIN AND VERIFY STRUCTURAL EVALUATION REPORT OF EXISTING TOWER AND EXACT PLACEMENT OF ANTENNAS AND COAX CABLES AND NOTIFY POCKET COMMUNICATIONS IN CASE OF A DISCREPANCY. ANY STRUCTURAL MODIFICATIONS, IF REQUIRED SHALL BE DONE PRIOR TO INSTALLATION OF ANTENNAS. REFER TO CORRESPONDING SHOP DRAWINGS. NOTES 1. ALL POCKET COMMUNICATIONS SAFETY PROCEDURES MUST BE ADHERED TO.. 2. ANTENNA SYSTEM SWEEP TESTING SHALL BE PER LATEST POCKET COMMUNICATIONS DOCUMENTS. 3. THIS DOCUMENT WAS DEVELOPED TO REFLECT A SPECIFIC SITE AND ITS SITE CONDITIONS AND IS NOT TO BE USED FOR ANOTHER SITE OR WHEN OTHER CONDITIONS PERTAIN. REUSE OF THIS DOCUMENT IS AT THE SOLE RISK OF THE USER. SCOPE OF WORK (INCLUDING BUT NOT LIMITED TO) 1. FURNISH AND INSTALL NEW CABINET SUPPORT STRUCTURE FOR TELECOMMUNICATIONS EQUIPMENT. 2. FURNISH AND INSTALL NEW COAX SUPPORT STRUCTURE. 3. FURNISH AND INSTALL NEW ELECTRICAL SERVICES WITH METER AND DISCONNECT. 4. FURNISH AND INSTALL ALL UNDERGROUND UTILITIES. 5. INSTALL NEW MOUNTS, ANTENNAS, CABLES, ETC. 6. INSTALL TELECOMMUNICATIONS EQUIPMENT. CONTACT INFORMATION CONTACT CONTACT COMPANY PHONE N0. ENGINEERING: GREG H. NAWROTZKI DEWBERRY (617) 695-3400 SAC: KEN KOZYRA KJK WIRELESS (603) 888-8974 CONST.: PAT,HEELAN PORTLAND CONSTRUCTION (207) 839-2076 ~~ De~uberry® Dewberry-Goodkind, Inc, 280 SUMMER ST. 10TH FLOOR BOSTON, MA.OP210- PHONE: fi17.~5.3400 FA%: 817.695,3310 327 KING STREET SITE N0. SPMA0050 327 KING STREET NORTHAMPTON, MA 01060 s ~~, t ~ ~~~ "-. >> 2 ~ w > `~ ~ ~ ~ -,, ,~ „~~ ~ ~ w U r~ r ' : 'b; ~ ~~ . ~ j _ :~ ~ f~. k*` SIIE1f1C9TIDN,:.. ~;~ f K YOrI ~~4fMOlD60 .. i CONTRACTOR'S WORK SHALL .COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION .(AHJ) FOR THE LOCATION. THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF CONTRACT AWARD 'SHALL GOVERN THE DESIGN. BUILDING CODE: MASSACHUSETTS STATE BUILDING CODE (780 CMR) ELECTRICAL CODE: MASSACHUSETTS ELECTRICAL CODE (527 CMR 12:00) }' [NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 70 - 2005, NATIONAL ELECTRICAL CODE, LIGHTNING PROTECTION CODE: [NFPA 780 - 2005, LIGHTNING PROTECTION CODE) l OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION (OSHA) CONTRACTOR'S WORK SHALL~COMPLY WITH THE LATEST EDITION OF THE FOLLOWING STANDARDS: I AMERICAN CONCRETE INSTITUTE jACQ 318, BUILDING CODE REQUIREMENTS fOR STRUCTURAL °~ CONCRETE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF STEEL CONSTRUCTION, ASD, NINTH 'EDITION SOCIATION (TIA) 222-F STRUCTURAL STANDARDS FOR STEEL -, „r~,,,P,~„- - `' ' TELECOMMUNICATIONS INDUSTRY AS , ANTENNA TOWER AND ANTENNA SUPPORTING STRUCTURES: s, ;.'- TIA 607, COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FOR - '' -_ T-ELfCOMMUNICATIDNS =,..,« „ io ~ ; ~ INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 81, GUIDE FOR MEASURING ~~ ' EARTH RESISTIVITY, GROUND IMPEDANCE, AND EARTH SURFACE POTENTIALS OF A GROUND ~' ° s ~ SYSTEM.. IEEE 1100 {1999) RECOMMENDED 'PRACTICE FOR POWERING AND GROUNDING 4F ELECTRONIC moo' `~r~e EQUIPMENT IEEE C62.41, RECOMMENDED PRACTICES ON SURGE VOLTAGES IN LOW VOLTAGE AC POWER ° " " '' ` A`g ~~ ~ "; ) HIGH SYSTEM ExP05URE AND C3 CIRCUITS ('FOR LOCATION CATEGORY ~ ; 7 ~L fpm 0~ ,~,t' ~ :,~ ' ~ ~ ` ~ TE600RDIA GR-1275, GENERAL INSTALLATION REQUIREMENTS n~ ~ TELCORDIA GR-1503, COAXIAL CABLE CONNECTIONS ,~,,_ . ANSI T1.311, TOR TELECOM - OC POWER SYSTEMS -TELECOM, ENVIRONMENTAL PROTECTION PROJECT INFORMATION FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING 1. THIS SITE IS UNMANNED AND IS RESTRICTED TO OUTDOOR EQUIPMENT, IT WILL BE USED FOR THE ' MATERIAL, METHODS OF CONSTRUCTION, OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE RAL REQUIREMENT 6 N I E W H U SERVICE. TRANSMISSION OF RADIO SIGNALS FOR THE PURPOSE OF PROVIDING PUBLIC CELLULAR GOVERN SHALL REQUNREMEN SPEC F C THE REQUIREMENT, A SPECIFIC AND 2. POCKET COMMUNICATIONS CERTIFIES THAT THIS TELEPHONE EQUIPMENT FACILITY WILL BE SERVICED CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS AS REQUIRED 'FOR ONLY BY POCKET COMMUNICATIONS EMPLOYEES AND THE WORK ASSOCIATED WITH ANY EQUIPMENT CANNOT BE PERFORMED BY HANDICAPPED PERSONS. THIS FACILITY WILL BE FREQUENTED ONLY BY. PROPER EXECUTION OF PROJECT. REPORT ANY CONFLICT OR DISCREPANCIES TO THE SERVICE PERSONNEL FOR REPAIR PURPOSES ONLY. THIS FACILITY IS EXEMPT FROM THE REQUIREMENTS CONSULTANT PRIOR TO CONSTRUCTION. OF THE AMERICANS WITH DISABILITIES ACT (ADA), APPENDIX B, SECTION 4.11.(5)(b). 3 NO POTABLE WATER SUPPLY IS TO BE PROVIDED AT THIS LOCATION. "!ia ' . jNOF1~ ~ ~ ~ ° ' 4. NO WASTE WATER WILL BE GENERATED AT THIS LOCATION. c~,P 4 S,Q~ ~ ~~ C HALF SIZE PRINT 5. NO SOLID WASTE WILL BE GENERATED AT THIS LOCATION. aft J ` G y lr ~~DFORD A. m S THIS DRAWING IS SCALEABLE E NOTED SCALE F T 6. POCKET COMMUNICATIONS MAINTENANCE CREW (TYPICALLY ONE PERSON) WILL MAKE AN AVERAGE OF ONE p~ MIL! S ~ i AT HAL H TRIP PER MONTH AT ONE HOUR PER VISIT. r~ , CIVIL t n ~0' ~~ POCKET COMMUNICATIONS ~ ~~Q SAN ANTONIO, TX 78215 0 10/02/OS ISSUED FOR CONSTRUCTION ROM GHN PP8 y1~,~ - - B 09/22/08 ISSUED FOR REVIEW ROM GHN PPB ~L/~~~`~7' ~\ TITLE SHEET COMMUNICATIONS A 09/02/D8 ISSUED FOR REVIEW ROM GHN PPB /L~/ NO.._DATE ..________ - REVISIONS.._._,_._...r _I3?'.. ~CHK APP'D {{//"~~ ~. DEWBERRY N0. JOB N0. DRAWING -'~BYS'AVENUE 1B'-' - rv'~` ~ o SAN ANTONIO, TX 78215 SCALE: AS SHOWN DESIGNED BY: ROM DRAWN BY: MR 50014749 '50014805 SPMADO GENERAL CONSTRUCTION NOTES: 1. ALL WORK SHALL CONFORM TO ALL CURREM APPLICABLE FEDERAL, STATE, AND LOCAL CODES, AND COMPLY WRH POCKET COMMUNICATIONS WIRELESS SPECIFICATIONS. 2. COMRACTDR SHALL CDMACT DIG SAFE (1 BB8 OIC SAFE BBB-344-7233) FOR IDEMIFICATION OF UNDERGROUND UALRIES PRIOR TO START OF CONSTRUCTION. J. COMRACTOR IS RESPONSIBLL FOR COORDINATING ALL REDUIRED INSPECTIONS. 4. ALL DIMENSIONS T0, OF, AND ON E%ISTING BUILDINGS, DRAINAGE STRUCTURES, AND SRE IMPROVEMENTS SHALL BE VERIFIED IN FIELD BY CONRACTOR WRH ALL DISCREPANCIES REPORTED TO THE ENGINEER. 5. DO NOT CHANGE SIZE OR SPACING OF STRUCTURAL ELEMENTS. 6. DETAILS SHOWN ARE TYPICAL; SIMILAR DETAILS APPLY 70 SIMILAR CONDRIONS UNLESS OTHERWISE NOTED.. 7. THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPDNEMS FOR CONSTRUCTION SAFETY WHICH IS THE SOLE RESPONSIBILRY OF THE COMRACTOR. 8. CONTRACTOR SHALL DRACE STRUCTURES UNTIL ALL STRUCTURAL ELEMENTS NEEDED FDR STABILRY ARE INSTALLED. THESE ELENENTS ARE AS FOLLOWS: LITERAL BRACING, ANCHOR BOLTS, ETC, 9. COMRACTOR SHALL DETERMINE FACT LOCATION'OF EXISTING UTILITIES, GROUNDS DRAINS, DRAIN PIPES, VEMS, ETC. BEFORE COMMENCING WORK. 10. INCORRECTLY FABRICATED, DAMAGED, OR OTHERWISE MISFRRNG OR NONCONFDRMINC MATERIALS OR CONDRIONS SHALL BE REPORTED TO THE OWNER PRIOR i0 REMEDIAL OR CORRECTNE ACTION. ANY SUCH REMEDIAL ACTION SHALL REQUIRE WRRTEN APPROVAL BY THE OWNER'S AEPRESEMATNE PRIOR TD PROCEEDING. 11. EACH CONTRACTOR SHAH. COOPERATE WRH THE OWNER'S REPRESEMATNE, AND COORDINATE HIS WORK WITH THE WORK OF OTHERS. 72. COMRACTOR SHALL REPAIR ANY DAMAGE CAUSED BY CONSTRUCTION OF THIS PROJECT TO MATCH EXISTING PRE-CONSTRUCTION CONDffIDNS TO THE SATISFACTION OF THE POCKET COMMUNICATIONS CONSTRUCTION MANAGER. iJ. ALL CABLE/CONDOR ENTRY/E%R PORTS SHALL BE WEATHERPROOFED DURING INSTALUTION USING A SILICONE SEALANT. 14. WHERE E%ISTING CONDRIONS DD NOT MATCH THOSE SHOWN IN THIS PLAN SET', CONRACTOR WILL NOTIFY ENGINEER, POCKET COMMUNICATIONS CONSTRUCTION MANAGER, PND UNOLORD IMMEDNTELY. 15. COMRACTOR SHALL ENSURE ALL SUBCDMRACTORS ARE PRONGED WRH A CURREM SET OF DRAWINGS AND SPECIFCATIONS FOR THIS PR0.)ECT. i6. COMRACTOR SHALL REMOVE ALL RUBBISH AND DEBRIS FROM THE SRE AT THE END OF EACH DAY. 17. COMRACTOR SHALL COORDINATE WORK SCHEDULE WRH UNDLORO AND TRICE PRECAUTIONS TO MINIMIZE IMPACT PND DISRUPTION OF OTHER OCCUPANTS OF THE FACILITY. 18. COMRACTOR SHALL FURNISH POCKET COMMUNICATIONS WRH THREE AS-BUILT SETS OF DRAWINGS UPON COMPLEAON OF WORK. 19. ANTENNAS AND CABLES ARE TYPICALLY PROVIDED BY POCKET COMMUNICATIONS. PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WRH POCKET COMMUNICATIONS CONSTRUCTION MANAGER TO DETERMINE WHAT, IF ANY, REMS WILL BE PROVIDED Bf POCKET COMMUNICATIONS. ALL REMS NOT PROVIDED BY POCKET COMMUNICATIONS SHALL BE PROWDED AND INSTALLED BY THE CONTRACTOR. COMRACTOR WILL INSTALL ALL REMS PROVIDED BY POCKET COMMUNICATIONS. 20. PRIOR TD SUBMISSION OF BID, COFffRACTOR WILL COORDINATE WRH POCKET COMMUNICATIONS CONSTRUCTION MANAGER TO DETERMINE IF ANY PERMTS WILL BE OBTAINED BY POCKET COMMUNICATIONS. ALL REDUIRED PERMTS NOT OBTAINED Bf POCKET COMMUNICATIONS MUST BE OBTAINED, AND PAID FOR, BY THE COMRACTOR. 21. COMRACTOR SHALL INSTALL ALL SRE SIGNAGE IN ACCORDANCE WRH POCKET COMMUNICATIONS SPECIFICATIONS AND REQUIREMEMS. 22. CONTRACTOR SHALL SUBMR ALL, SHOP DRAWINGS TO DEWBERRY FOR REVIEW ANO APPROVAL PRIOR TO FABRICATION. 23. UNLESS OTHERWISE NOTED POCKET COMMUNICATIONS SHALL PRWIDE ALL REDUIRED RF MATERML FOR CDMRACTOR TO INSTALL, INCLUDING ANTENNAS, TMA'S, BMS-T'S, COMBINERS, PDU, DC BLOCKS, SURGE ARRESTORS, GPS ANTENNA, GPS SURGE ARRESTOR, COAXIAL CABLE 24. PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL VERIFY AIL EQUIPMEM TO BE PROVIDED Bf POCKET COMMUNICATIONS FOR INSTPLUTION BY CONTRACTOR. 25. PLL EOUIPMEM SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S SPECIFICATIONS AND LOCATED ACCORDING TO POCKET COMMUNICATIONS SPECIFCATIONS, ANO AS SHOWN IN THESE PUNS. 26. SEAL PENETRATIONS THROUGH FIRE RATED AREAS WRH UL LISTED D FlRE CODE APPROVED MATERIALS. 27, THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HERdN. THE COMRACTOR SHALL BE SOLEY RESPONSIBLE FDR PLL THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDIN4TING ALL PORADNS OF THE WORK UNDER THE CONTRACT. 28. COMRACTOR SHALL NOTIFY DEWBERRf A MINIMUM DF 48 HOURS IN ADVANCE OF POURING CONCRETE OR BACKFlWNG ANY UNDERGROUND tlflLfDES, FOUNDATIONS OR SEALING ANY WALL FLOOR OR ROOF PENETRATIONS FOR ENGINEERING REVIEW AND APPROVAL ~~ Dewberry® Dewberry•Goodkind,Tnc, 2A0 SUMMER ST. 10TH FLOOD FP%:817.&95.3310 STRUCTURAL STEEL NOTES 1. STRUCTURAL STEEL SHALL CONFORM TO THE UTEST EDITION OF THE RISC "SPECIFlCATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS". 2. ALL EXTERIOR STEEL WORK SHALL BE GALVANIZED IN ACCORDANCE WRH SPECIFICATION ASTM A123 HOT-DIP GALVANIZED FINISH UNLESS OTHERWISE NOTED. GALVANRING SHALL BE PERFORMED AFTER SHOP FPBRICATIDN TO THE GREATESTEXTENT POSSIBLE. ALL DINGS, SCRAPES, MARS, AND WELDS IN THE GALVANIZED AREAS SHALL BE REPAIRED. REPAIR DAMAGED GALVANIZED COATINGS ON GALVANIZED REMS WRH GALVANZED REPAR PAINT ACCORDING TO ASTM A780 AND MANUFACTURER'S WRRTEN INSTRUCTIONS, PRIOR TD COMPLETION OF WORK. 3, DO NOT'ORILL HOLES THROUGH STRUCTURAL STEEL MEMBERS EXCEPT AS SHOWN AND DETAILED ON STRUCTURAL DRAWINGS. 4. CONNECTIONS: a) ALL WELDING SHALL BE DONE USING E70XX ELECTRODES AND WELDING SHALL CONFORM TD RISC AND AWS 01.1. WHERE FILLET WELD SIZES ARE NOT SHOWN, PROVIDE THE MINIMUM SIZE PER TABLE J2.4 IN 7HE RISC "MANUAL OF STEEL CONSTRUCTION' 9TH EDITION. AT THE COMPLETION OF WEl01NC, ALL DAMAGE TO GALVANIZED COATING SHALL BE REPAIRED. R IS THE COMRACTDR'S RESPONSIBILRY TD PROVIDE BURNING/WELDING PERMITS AS REQUIRED BY IDCAL GOVERNING AUTHORITY, AND IF REQUIRED SHALL HAVE FIRE DEPARTMENT DETAIL FOR ANY WELDING ACTNItt. b) BOLTED CONNECTIONS SHALL USE BEARING TYPE GALVANZED ASTM A325 BOLTS (S,IZE AS NOTED) AND SHALL HAVE MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE c) CONNECTION DESIGN fN' FABRICATOR WILL BE SUBJECT TO REVIEW AND APPROVAL BY ENGINEER. 5. -WELDING SHALL MEET THE AMERICAN WELDING SOCIETY STRUCNRAL WELDING CODE-STEEL WELDING OPERATORS SHALL BE CERTIFIED BY THE STANDARD QUALIFlCATIONS AWS PROCEDURE FOR THE ttPE OF WELD REDUIRED. fi. SDUARE AND PLUMB THE STRUCTURE BEFORE TIGHTENING BOLTED CONNECTIONS DR WELDING ANY FIELD WELDED CONNECTIONS. SEE AJSC SPECIFICATIONS 7.11.3. ' PERMIT (STRUCTURAL NOTES: 1. STRUCTURAL ANALYSIS/POWER DESIGN ODNE BY OTHERS. 2. POCKET COMMUNC4TION5 SHALL PROVDE A STRUCNRAL ANALYSIS OF THE TOWER PREPARED BY A LICENSED MASSACHUSETTS STRUCTURAL ENGINEER CERRFI1NG THAT, THE IXI5IING TOWER AND PNY REQUIRED IMPROVEMENTS AND REINFORCEMEMS HAVE SUFFlCIEM CAPACRY TO SUPPORT ALL EXISTING AND PROPOSED AMENNAS, SUPPORTS AND APPURTENANCES AND COMPLIES WITH THE CURREM MASSACHUSERS STATE BUILDING CODE AND EIA/TU CRffERU. THE CONTRACTOR IS RESPONSIBLE TO CONFIRM THAT ANY ANO ALL IMPROVEMENTS AND REINFORCEMEMS REDUIRED Bi THE STRUCTURAL ANALYSIS CERTIFICATION ARE PROPERLY INSTALLED PRIOR TO THE ADDI80N OF AMENNAS, SUPPORTS AND APPURTENANCES PROPOSED ON THESE DRAWINGS OR OTHERWISE NOTED IN THE STRUCNRAL ANALYSIS. AMENNA AND COAXIAL CABLE BILL OF MATERALS ' COAX CABLE AZIMUTH RAD COAXIAL COAXIAL ELECTRICAL SECTOR STATUS COLOR CODE ANTENNA FEED LOC (TRUE NORTH) CENTER CABLE LENGTH CABLE OOWNTILT ALPHA PROPOSED RED Ap%V18 2065175-C BOTTOM 30' 160' 2 ®190' (2)R~5/8. SEE NOTE 2 BETA PROPOSED BWE BOTTOM 190' 160' 2 ® 190' 3/B" ~ ~2) R SEE NOTE 2 Ap%V18-206517S-C F GAMMA PROPOSED GREEN AP%V18 2065175-C BOTTOM 290' 160' 2 ®180 (2) RFS/8F. SEE NOTE 2 CPS PROPOSED - NTGBOtMA-GPS - - - - - - TOTAL 3 1140' DUAMITY NOTES: 1. CDA%IAL CABLE IS RFS LCF158-50JL OR AS SUPPLIED. 2. REFER TO REDS AMENNA SHEEt FDR FINAL TILT AND AZIMMHS. ANTENNA AND COAXIAL CABLE B.O.M. n SCALE: N.T.S. I CONCRETE AND REINFORCING STEEL NOTES: 1. DESIGN AND CONSTRUCTION OF ALL CONCRETE ELEMENTS SHALL CONFORM TD THE UTEST EDRIDNS OF ALL APPLICABLE CODES INCLUDING: ACI 301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE FDR BUILDINGS", AND ACI J78 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE'. 2: MIX DESIGN SHALL BE APPROVED BY OWNER'S REPRESEMATNE ANO SUBMITTED TO ENGINEER PRIOR TO PLACING CONCRETE. 3. CONCRETE SHALL BE NORMAL WEIGHT, 6 R AIR EMRAINED (+/- 1.5X) WITH A MAXIMUM 4"-SLUMP AND HAVE A MINIMUM 28-DAY COMPRESSNE STRENGTH OF 4000 PSI UNLESS OTHERWISE NOTED. 4. THE FOLLOWING MATERIALS SHALL BE USED: PORTLAND CEMEM: A9TM C-150, TYPE 1 OR 2 REINFORCEMEM: p6TM A-1B5, PUIN STEEL WELDED WIRE FABRIC REINFORCEMEM BARS: ASTM A615, GRADE 60, DEFORMED NORMAL WEIGHT AGGREGATE: ASTM C-33 WATER: DRINKABLE ADMXUAES: NON-CHLORIDE CDMNNING 5. MINIMUM CONCREFE COVER FOR REINFORCING STEEL SHAD. BE AS FOLLOWS (UNLESS OTHERWISE NOTED): A. CONCRETE CAST AGAINST EARTH: 3" B. ALL OTHER CONCRETE: 2" 6, A 3/4" CHAMFER SHALL BE PROVIDED AT ALL E%POSED EDGES OF CONCRETE IN ACCORDANCE WITH ACI 301 SECTION 4.2.4, UNLESS NOTED OTHERWISE 7. INSTAIJATION OF CONCRETE EXPANSION/WEOGE ANCHOR SHALL BE PER MANUFACTURER'S WRRTEN RECOMMENDED PROCEDURE. THE ANCHOR BOLT, DOWEL, OR ROD SHALL CONFORM TO MANUFACTURER'S RECOMMENDATION FOR EMBEDMEM DEPTH OR 15 SHOWN ON THE DRAWINGS. NO REPAR SHALL BE CUf WffHDUT PRIOR ENGINEERING APPROVAL WHEN DRILLING HOIFS IN CONCREFE. 8, ADMIXTURES SHALL~CONFORM TO THE APPROPRIATE ASfM STANDARD PS REFERENCED IN ACI 301. 9. DO NOT WEIR OR TACK WELD REINFORCING STEEL ' 10. ALL DOWELS, ANCHOR BOLTS, EMBEDDED STEEL, ELECTRICALCONDURS, PIPE SLEEVES, GROUNDS AND ALL OTHER EMBEDDED ITEMS AND'FORMEO DETALS SHALL BE IN PLACE BEFORE START OF CONCRETE PLACEMEM. 11. REINFORCEMEM SHALL 8E COLD BEM WHENEVER BENDING IS REQUIRED, 12. DO NOT PUCE CONCRETE IN WATER, ICE, OR ON FROZEN GROUND. 13. DO NOT ALLOW REINFORCEMEM, CONCRETE OR SUBBASE TO FREEZE DURING CONCRETE CURING AND SETTING PERIOD, DR FDR A MINIMUM OF 3 DAYS AFTER PUCEMENT., 14. FOR COLD-WEATHER AND HOT-WEATHER CONCRETE PIACEMEM, CONFORM TO APPLICABLE ACI CODES AND RECOMMENDATIONS. IN ERHER CASE, MATERIALS COMAINING CHLORIDE, CALCIUM, SALTS, EEC. SHALL NOT BE USED. PROTECT FRESH CONCRETE FROM WEATHER FOR 7 DAYS, MINIMUM. 15. CONCRETE SHALL BE RUBBED TD A ROUGH GROUTFINISH. PADS SHALL BE SEALED BY STEEL TROWf1 1fi. UNLESS OTHERWISE NOTED: A ALL REINFORCING STEEL SHALL BE'DEFORMED B4f25 CONFORMING TO PSTM A615, GRADE 60. B. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A1B5. 17. SAUCING OF RFJNFORCEMEM LS PERMITTED ONLY AT LOCATIONS SHOWN IN THE CONTRACT DRAWINGS OR AS ACCEPTED BY THE ENGINEER. UNLESS OTHERWISE SHOWN OR NOTED REINFORCING STEEL SHALL BE SPLICED TO DEVELOP RS FULL TENSILE CAPACItt 1ClASS A) IN ACCORDANCE WRH ACI 318. 18: REINFORCING BAR DEVELOPMEM LENGTHS, AS COMPUTED IN ACCORDANCE WRH ACI 318, FORM THE BA515 FOR BAR EMBEOMEM LENGTHS AND BAR SPLICED LENGTHS SHOWN IN THE DRAWINGS. APPLY APPROPRATE MODIFlCATION FACTORS FOR TOP STEEL BAR SPACING, COVER AND 7HE IJKE. 19. DETAILING OF REINFDftCING STEEL SHALL CONFORM TO "ACI MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES" (ACI 315). 20. ALL SUB CONSTRUCTION SHALL BE CASE NONOLIIHICALLY WII}iOUT HORROMAL CONSTRUCTION JOINTS, UNLESS SHOWN IN THE CONTRACT DRAWINGS. 21. LOCATION OF ALL CONSTRUCTION JOIMS ARE SUBJECT TD THE REQUIREMENTS OF THE CONTRACT DOCUMENTS, CONFORMWJCE WRH ACI 318, AND ACCEPTANCE OF THE ENGINEER. DRAWINGS SHOWING LOCATION OF DETAILS OF THE PROPOSED 'CDNSTRUCTWN JOIMS SHALL BE SUBMTTED WITH REINFORCING STEEL PUCEMEM DRAWINGS. 22. SAUCES OF WWF, AT ALL SPLICED EDGES, SHALL BE SUCH THAT THE OVERUP MEASURED BETWEEN OUTERMOST CROSS WIRES OF EACH FABRIC SHEEP IS NOT LESS TWW THE SPACING OF THE, CROSS WIRE PLUS 2 INCHES, NDR LESS THAN 8". 2J. BAR SUPPORTS SHALL BE ALL-GALVANIZED METAL WRH PLASTIC TIPS. 24. ALL REINFORCEMEM SHALL BE SECURELY TIED IN PUCE TO PREVEM DISPUCEMEM fD' CONSTRUCTION TRAFFIC OR CONCRETE. TIE WIRE SHALL BE i6 GAUGE CONFORMING TD ASTM A82. 25. SUB ON GROUND A. COMPACT STRUCTURAL FILL TO 95X DENSRY AND THEN PUCE 6"GRAVEL BENEATH STAB. B. PROVIDE VAPOR BARRIER BENEATH SUB ON GROUND. - o~~~.LSN Of'19~SS~~ti FJ' ~ ®~~O~D A N - ~ ~W.~S. ~ HALF SIZE PR[N'T ~~ THIS DRAWING IS SCALEABLE AT HALF THE NOTED SCALE ~ ~~• ~ POCKET COMMUNICATIONS No. a396S ~ SAN ANTONIO, TX 78215 327 KING STREET D 10/02/08 ISSUED FOR CONSTRUCTION ROM GHN PPB ~ ~Q 1LQ'~ ~T~ SITE N0. SPMA0050 O B 09/22/08 ISSUED FOR REVIEW ROM GHN PPB ,r~~~~/R` S~ / ' ro 1• GENERAL NOTE$ & ANTENNA B.O.M. 327 KING STREET COMMUNICATIONS A 09/02/08 ISSUED FOR REVIEW ROM GHN PPB PJA ~ .i • NORTHAMPTON, MA 01060 ~ _ ^, , DEWBERRY N0. JOB N0. DRAWING NUMBER RE 8'1'5 AVENUE `B' ND. -DATE- REVISIONS _BY_ .CHK. AP_P D _ ~.~. ._, .~ SAN ANTONIO, TX 78215 SCALE: AS SHOWN 'DESIGNED BY: ROM DRAWN BY: MR ~d' z' 50014749 50014805 SPMA0050-G01 C EXISTING 12'. WIDE ^ SWING GATE \ / ~N \ / x ~ ~ x . W ~~ x-~ x- EXISTING _ _ STEEL STAIRS I I- (- h + g` / /+ I I L-- EXISTING B' TALL + CHAIN LINK FENCE / ~ I ' WITH 3 STRANDS OF BARBED WIRE + IXISTING 12'x20' USI EQUIPMENT SHELTER _ k ~ EXISTING 1 / EOUIPMED + PROPOS s'x1D' LEASE AREA (60 S0. Fi.) . i 4 x C01 EXISTING EXISTING GENERATOR ON METER RACK CONCRETE PAD (TYP.) . x ---- 0 1 cD1 Teico coourDr 1'-4° , I % I I I I I EXISTING 9' WIDE ~ 3'-0" SWING GATE I 1 x I I J ~ x 1,-7" L I PROPOSED 24' ~ > e PROPOSE WIDE ICE BRIDGE ~ COt GPS ANTENNA ~ (LENGTH=13't) / 6 E%ISTING ~ C01 iE~PEDESTAL xl 2 PROPOSED C01 UNDERGROUND x POWER CONDUIT x EXISTING 10'x20' 1D NEXTEL EQUIPMENT SHELTER EXISTING 17'-B"xJl'-6" rSTEEL PLATFORM x-xD X x x I x I"x30'-D" IELE55 ( HELTER x I x 190't A.C.L TALL EXISTING MONOPOLE SAFEtt RAILING EXISTING ~~) \~ICE BRIDGE (ttP.) EXISTING 11'x16' AT&T EQUIPMENT SHELTER I x EXISTING UTILItt POLE / MI5-5 x i I-x-x-x-x-x-x-x-xx-x NOTES: 1. SOME EXISTING & PROPOSED INFORMATION NOT SHOWN FOR CLARftt. 2. NORTH SHOWN AS APPROXIMATE. J. ANTENNAS, MOUNTS & COAX TO BE INSTALLED PER TOWER MANUFACTURER RECOMMENDATIONS & TOWER ANALYSIS SPECIFlCATIONS. SEE STRUCTURAL NOTE ON SHEET G-1. 4. PLANS BASED ON OBSERVATIONS MADE DURING SRE VISIT BY DEWBERRY-GOODKIND, INC., ON D8-15-OB 5. DEWBERRY-GOODKIND, INC. HAS NOT BEEN CONTRACTED TO PREPARE OR BEEN PROVIDED WffH A TOWER STRUCTURAL ANALYSIS AND THEREFORE ASSUMES NO RESPONSIBILITY FOR~THE TOWER OR R'S EXISTING OR PROPOSED ANTENNA INSTALLATIONS., ti„ ~~ Dewberry® Dewberry-Goodkind, Inc, 280 SUMMER ST. 10TH FLDDR BOSTON, MA_0210_ PHONE: B1 1.895.3400 FAX:817.~5.331D 3 ADt PROPOSED SITE PLAN ~ SCALE: 3/16°=1'-0" 0' 4' 8' t 2' 327 KING STREET SITE N0. SPMA0050 327 KING STREET NORTHAMPTON, MA D1D60 ~~ $dTENNA NOTES: 1. AZIMUTHS BASED ON APPROXIMATE TRUE NORTH 2. CONTRACTOR TD VERIFY FlNAL AZMIUTHS PRIOR TO AMENNA INSTALLATION. ANTENNA ORIENTATION KEY n SCALE: N.T.S. x EXISTING CONCRETE STRIP x ~EXISTINC HVAC UNIT (ttP.) x PROPOSED COMMUNICATIONS PN (1/SECTOR) (' 1 G01 190't A.G.L. TALL MONOPOLE EXISTING 10'x20' NEXTEL EQUIPMENT SHELTER x~ EXISTING TELCD PEDESTAL E%ISTING 8' TALL x CHNN LINK FENCE WITH J sreANDs OF BARBED WIRE x x-x ~o 0 iD/02/08 ISSUED'FOR CONSTRUCTION ROM GHN 0 B 09/22/08 ISSUED FOR REVIEW ROM. GHN COMMUNICATIONS A 09/02/08 ISSUED FOR REVIEW ROM GHN ~8T5'AVENUE-~B~ N0, -DATE-. R~^IISIONS _BY_ .CHK SAN ANTONIO, TX 78215 SCALE AS SHOWN DESIGNED BY: ROM DRAWN BY: MR TOP OF EXISTING MONOPOLE _ ELEV. = 190 =0"t A.C.L. _C,L, OF EXISTING ANTENNAS_ _ ELEV. = iB0'-0"t A,G.L. C.L. OF EXISTING ANTENNAS _ ELEV. = I70'-0"t A.G.L _ _ C.L OF PROPOSED ANTENNAS _ ELEV = 160'-0"t A.G.L. C.L, OF EXISTING ANTENNAS _ ELEV. = 147 =0"t A.G.L. C.L. OF EXISTING ANTENNAS _ ELEV. = 730=6"f AC.L. C.L. 9F EXISTING ANTENNAS_ _ ELEV. = 720'-0"t A:G.L. EXISTING 11'-B°z30'-0' VERIZON WIRELESS EQUIPMENT SHELTER EXISTING ON STEEL PLATFORM ICE BRIDGE (ttP.) EXISTING SAFETY RAILING (TYP.) E%ISTING 1T-8"x3T-6" STEEL PLATFORM EXISTING 11'x16' m :T EQUIPMENT SHELTE GRADE LEVEL ELEVATION 3 SCALE: 1/B"=1'-0° 0' 4' B' 16' ~~~~j1• Gf gegs~~c~ g 3RADFOii~ R. ~N ~ MILS ~ ~ O OIVIL q , N0.33966 HALF SIZE PRINT .THIS DRAWING IS SCALEABLE' AT HALF THE NOTED SCALE POCKET COMMUNICATIONS 'SAN ANTONIO, TX 78215 PROPOSED SITE PLAN & ELEVATION DEWBERRY N0. JOB N0. DRAWING NUMBER RE 50014;49 50014805 SPMA0050-AD1 U I _ ANTENNA JUMPERS '"J .. _ .. unun POLE T1/E1 UPPER AND ~ (~15-5) LOWER ENTRf~ PORTS _..._...._ ~1 BACK OF EQUIPMENT MOUNT 1" CONDUff . COUPLER FIRING PROPOSED POCKET REMOVE COVER TO 2" RCS COMMUNICATIONS UTILItt ACCESS GROUND .RISER METER (COORDINATE WRH MO . TERMINAL ~ UTILfn COMPANY' • o O PROPOSED RISER 1' FLIXIBLE CONDOR ~ a ~ BTS 3231 EQUIPMENT EABINEi FROM SRE S4FETY GND 200-240VAC ~.., - ~ I I I~~~JIkI,,ILal~a~~ ~ ~ u (I I RANCE CABLE `c I I ` 'iDC IN 1' PVC / 10 1 3 - `CUSTOMER AU \ / , ~ }) 1. SAFEn GROUND SHOULD BE THE SHORTEST DISTANCE WHILE MAINTAINING ROUTING REOUIREMENIS. ` ~~ - ~ - - - - - Z / 1/ INSTALL CONDOR PER SRE REQUIREMENTS 2 TYPICAL CONDUIT ROUTING SHOWN \ . . . \\ // 3. RIDGED CONDOR MAY BE USED IF REQUIRED. ~ - - \ - - - - - - - - - - - - ~ ~~ / BTS 3231 TYPICAL CELL SITE CABLING DETAIL ~ SCALE: N.T.S. ' . 4 SCH 40 PVC 4 CONDOR W/ 3/8" NriON PULL ROPE ELECTRICAL RISER DIAGRAM L ' SCALE: N.T.S. GENERAL ELECTRICAL NOTES 1. ALL ELECIRIC4L WORK SHALL BE DONE IN ACCORDANCE WRH ALL GOVERNING STATE, COUNn ANO LOCAL. CODES, D.S.H.A, NEC 2005, NFPA ~'7D, POCKET COMMUNICATIONS. AND THE SPEgFlCATI0N5 DETAILED IN THESE PWJS. 2. SUBMRTAI OF RID INDICATES CONTRACTOR IS CDCNIZALIf OF All JOB SAE CDNOITIONS AND WORN TO BE PERFORMED UNDER THIS CONTRACT. 3. CONTRACTOR SHALL PERFORM ALL VERIFICATION, OBSERVATWN, TESTS, AND E%AMINATION WORK PRIOR TO THE ORDERING OF 1HE ELECTRICAL EQUIPMEM AND THE ACNAL CONSTRUCTION. CONTRACTOR SH4LL ISSUE A WRTREN NOTICE OF. ALL FlNDINGS TO THE PROJECT MANAGER LISTING ALL MALFUNCTIONS, FAULTY EQUIPMENT, AND DISCREPANCIES. 4. THESE PLANS ARE DIAGRAMMATIC ONLY, FOLLOW AS CLOSELY AS POSSIBLE CONTRACTOR SHALL ENSURE THAT ACCESS TO EQUIPMEM IS MAINTAINED IN ACCORDANCE WRH MANUFACNRER SPECIFlCATIONS ANO ALL APPLICABLE COOES.~ 5. CONTRACTOR SHALL PROVIDE ALL LABOR, MATERMLS, INSURANCE, EQUIPMENT, INSTALLATION, CONSTRUCTION TOOTS, TRANSPORTATION, ETC., FOR A COMPLETE AND PROPERLY OPERATNE SYSTEM, ENERGRED THROUGHOUT AND AS INDICATED ON DRAWINGS, AS SPECIFIED HEREIN AND/DR AS OTHERWISE REQUIRED. 6. PLL MATERWS AND EQUIPMENT SHALL BE NEW AND IN PERFECT CDNDRION WHEN INSTALLED ANO SHALL BE OF THE BEST GRADE AND'OF THE SAME MANUFACTURER THROUGHOUT FDR EACH CLASS OR GROUP OF EQUIPMENT. MATERINS SHALL BE LISTED PNO APPRCVEO BY UNDEAWRRER'S LABORATORf AND SHALL BEAR THE INSPECTION !ABEL "UL" WHEflE SUBJECT TD SUCH APPROVAL MATERMLS SHALL MEET WffH APPROVPL OF ALL APPLICABLE STANDARDS ESTPBLISHED Bi AN51, NEM4 IEEE, AND NFPA GOVERNING BODIES HAVING JURISDICTION. MATERIALS SHALL BE MANUFACTURED IN ACCORDANCE W11H APPLICABLE STANDARDS FSTABUSHED BY ANSI, NEMA, AND NBFU. 7. COMPLETE JOB SHALL BE GUARANTEED FOR A PERIOD DF ONE (1) YEAR AFTER THE DATE OF JOB ACCEPTANCE BY OWNER. PN1' WORK, MATERIAL OR EQUIPMENT FOUND TD BE FAULtt DURING THAT PERIOD SHALL BE CORRECTED AT ONCE, UPON WRRIEN NOTIFICATION, AT THE E%PENSE OF THE CONTRACTOR. ' 8. 'PLL 'CONDOR ONLY (C,OJ INSTALLATIONS SHALL HOVE A 3/B' PULL WIRE OR ROPE 9. CONTRACTOR SHALL PROVIDE POCKET COMMUNICATIONS MANAGER WTIH ONE SET OF COMPLETE' ELECTRICAL 'AS INSTALLED' DRAWINGS AT THE COMPLEOON OF THE JOB, SHOWING ACTUAL DIMENSIONS, ROUTINGS, AND CIRCUITS. ~ - 10. ALL BROCHURES, OPERATING MANUALS, CATALOGS', SHOP DRAWINGS, ETC. SHALL BE TURNED OVER TO OWNER AT JOB COMPLETDN. 11. POWER WIRE AND CABLE CONDUCTORS SHALL BE COPPER X12 AWG MINIMUM UNLESS SPECIFlCALLY NOTED OTHERWISE ON DRAWINGS, CONDUCTORS X10 AWG AND SMALLER SHALL BE SOLID. 12. A1L CONDUCTORS WiGER THAN ~1D AWG SHALL BE STRANDED COPPER WAH THWN 600V INSUUTWN, UNLESS NOTED OTHERWISE 13. ALL MATING SURFACES OF GROUND CONNECTIONS SHP11 BE CLEANED~SMOOTH AND COATED WffH AMIOXIDANf PRIOR TD ATTACHMENT. 14. A1L GROUND CONNECTIONS BELOW GRADE MUSE RE IXOTFIEAMICALLY WELDED (CAD WELD OR APPROVED EQUAL) 15. ALL EXTERIOR CROUNOINC CONDUCTORS SHALL RE r2 AWG SDDO i1NNED BARE COPPER WIRE UNLESS NOTED OTHERWISE. ' 16. ALL CIRCUR BREAKERS, FUSES AND ELECTRICAL EQUIPMENT SHALL HAVE AN INTERRUPTING RATING NOT LESS THE MAXIMUM SHORE CIRCUR CURREM TO WHICH THEY MAY BE SUBJECTED, ANO A MINIMUM OF 10,OOD AI.C. COORDINATE SHORT CIRCUR REQUIREMENTS WRH LOCAL lR1LITY COMPANY. 17. IN DRILLING HOLES INTO CONCRETE WHETHER FOA FASTENING OR ANCHORING PURPOSES, OR PENETRATIONS THROUGH THE FLOOR FOR CONDOR RUNS, M PIPE RUNS, ETC., R MUST BE CLEARLY UNDERSTOOD THAT TENDONS ANO/OR REINFORCING STEEL WILL NOT BE DRILLED INTO, CUT OR DAMAGED UNDER ANY CIRCUMSTANCES. 18. LOCATION OF TENDONS AND/OR REINFORCING STEEL ARE NOT OEFlNRELY KNOWN AND, THEREFORE, MUSE BE SEARCHED FOR BY APPROPRIATE METHODS AND EpUIPMELIT VN X-RAY OR OTHER DEVICES THAT CAN ACCURATELY LOCATE THE REINFORCING AND/OR STEEL TENDONS. 19. ALL MAIERINS SHALL RE U.L LISTED. ~~~ Dewberry® Dewberry-Goodkind, Inc, 280 SUMMER ST. 18TH FLOOR FA%:817.~5.3310 327 KING STREET SITE N0. SPMA0050 327 KING STREET NORTHAMPTON, MA 0106D 20 CONDOR: , o. RIGID CONDUIT SHALL BE U.L LABEL GALVANIZED ZINC COATED WITH ZINC INTERIOR AND SHALL BE USED WHEN INSTAllEO IN OR UNDER CONCRETE SLOBS, IN CONTACT WRH THE EARTH, UNDER PUBLIC ROPDWAYS, IN MASONRY WALLS OR EXPOSED ON BUILDING EXTERIOR. RIGID CONDOR IN CONTACT WRH EARTH SHALL BE 1/2 TAPPED RAPPED WITH HUNTS WRAP PROCESS N0. 3. b. ELECTRICAL METALLIC TUBING SHALL HAVE U.L LABEL FfiTINGS SHALL BE GIANO RING COMPflESSION TYPE. EMT SHALL BE USED ONLY FOR INTERIOR RUNS c FLE%IBLE METALLIC CONDOR SHALL HAVE U.L USlEO LABEL AND MAY BE USED WHERE PERMfifED Bi CODE. FlTTINCS SHALL BE "JAKE' OR "SQUEEZE" TYPE, SEAL TIGHT FLE%IBIE CONDOR. ALL CONDOR SHALL HAVE FULL SIZE GROUND WIRE. 21. All ELECTRICAL EQUIPMENT SHALL BE LABELED WRH PERMANENT ENGRAVED PLASTIC LABELS. 22. CONTRACTOR SHALL COORDINATE THE ELECTRICAL SERVICE WITH POCKET COMMUNICATIONS ANO LOCAL UTILRY. 23. THE ENTIRE ELECTRIC4L IN5TALUTION SHALL RE GROUNDED 0.S REDUIRED BY NEC AND ALL PPPUCABLE CODES. 24. GROUNDING SYSTEM RESISTANCE SHALL NOT EXCEED 5 OHMS. IF THE RESISTANCE VALUE IS EXCEEDED, NOTIFY THE OWNER FOR FURTHER INSTRUCTION ON MEMODS FOR REDUCING THE RESISTANCE VALUE. CONTRACTOR SHALL SUBMR TO THE PROJECT MANAGER ALL TEST REPORTS AND ONE COMPLETE SET OF PRINTS SHOWING "INSTALLED WORK". 25. UPON COMPLETION OF WORK, CO1JbULT COMINUIIY, AND FALL OF POTENTIAL GROUNDING TESTS FOR APPROVAL SUBMR TEST REPORTS TO PROJEC'T' MANAGER. CLEAN PREMISES OF ALL DEBRIS RESULTING FROM, WORK AND LEAVE WORK IN A COMPLETE AND UNDAMAGED CONDIRON. 26. ALL E%PDSEO GROUND WIRES ADItfED ALONG THE SIDE OF EQUIPMEM SHELTERS OR ROUTED OVER CONCRETE FOUNDATIONS OR OTHER IXI511NG STRUCTURES SHP1.L BE INSTALLED IN PROPERLY ANCHORED 3/4'm (MIN.) PJC CONDUIT. 27. CONRACTOR SHALL NOT DISNRB E%ISTING GROUNDING SYSTEM. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY AT NO ADDITIONU corr. 2B. ALL INTERIOR CABLES AND WIPING SHALL BE NEATLY ROUTED IN OVERHEAD UDDER RACK AND FASTENED TO !ADDER RACK. 29. ALL GROUNDING CONDUCTORS SHALL RE ROUTED DOWNWARDS FROM POIM OF ORIGIN TO TERMINATION POINT (GROUND B4R, GROUND RING, ETC. 30. GROUNDING CONDUCTORS SHALL NOT REVERSE DIRECTION {E%CEPf HALO 8 BURIED GROUND RINGS). OTHER EXCEPTIONS NEED TD BE APPROVED BY POCKET COMMUNICATIONS CONSTRUCTION MANAGER PRIOR TO INSTALLATION. 31. GROUNDING CONDUCTORS SHALL HAVE A MINIMUM BENDING RADIUS OF 8". 32. ALL CONNECTIONS TO GROUND PLATES SHALL BE CAD WELDED TO THE CENTER OF THE PLATE. All DETAl15 SHOWING CONNECTIONS TO GROUND RODS ARE ALSO YALO FOR SIMILAR CONNECTIONS TD GROUND PUTES. O COMMUNICATIONS SAN ANTONIO, TX 78215 D 10/02/08 ISSUED FOR CONSTRUCTION ROM GNN PPB B 09/22/08 ISSUED FOR REVIEW ROM GHN PPB A 09/02/08 ISSUED FOR REVIEW ROM GHN PPB AS SHOWN (DESIGNED BY: ROM IORAWN BY: MR FRONT OF EQUIPMENT MOUNT 24" WIDE ICE BRIDGE PPC OVER EQUIPMENT -PROPOSED PPC ~~ u 1" FLIXIBLE CONDUIT __¶T -3/4"%10' LONG COPPERGROUND ROD 24' WIDE ICE BRIDGE OVER EOUIPMEM BTS 3237 ~EOUIPMENT CABINET ELECTRICAL AND TELEPHONE GENERAL NOTES: 1. "FOLLOWING COMPLETION-0F WORK, PROVIDE OWNER WRH AS-BUILT DRAWINGS SHOWING TELEPHONE AND ELECTRIC LOCATIONS. 2. WORK SHALL CONFORM TO THE NA7IDNAL ELECTRICAL CODE, NEC 2005. 3. COORDINATE WITH UTILffY AND LOCAL ELECTRICAL INSPECTOR FOR FINAL POWER CONNECTION. 4. UiILRY WILL SUPPLY METER. LOORDINATE WRH UTILTIY FOR METER TYPE AND INTERCONNECTION. ' 5. ALL E%ISTING UNDERGROUND LINES ON SITE TO BE LOCATED PRIOR TO CONSTRUCTION. CALL i-888-DIG-SAFE PRIOR TO CONSTRUCTION. 6. SEAL ALL SERVICE ENTRANCES INTO SHELTER FOLLOWING INSTALLATION. 7, SEE PACE E02 FDR-GENERAL~GROUNDING NOTES: B. COORDINATE WITH LOCAL TELEPHONE COMPANY FOR ALL ROUTING AND DESIGN. p~~~PLj}i Qr ~SS~~ g' BRJ4DFO+~D14. m o ~li.l3 ..I U ~~, p'1y _ No, 33966 HALF SIZE PRIIVT THIS DRAWING IS SCALEABLE AT HALF THE NOTED SCALE POCKET COMMUNICATIONS SAN ANTONIO, TX 78215 ELECTRICAL RISER DIAGRAM & BTS 3231 DETAIL DEWBERRY N0. JOB N0. DRAWING NUMBE 50014749 5'DD14805 SP~4AODSD-E01 ~N a~ N.EC. ~~ GROUND RGD \ II i ,~ ~" ~q` i BOND T0+ - - -/'/ 1\ EXISTING GROUND RING (V.I.F.) 5 EQUIPMINT E03 GROUND BAR 1 PROPOSED COPPER-CIAO STEEL ED3 GROUND ROD. 5/8"0 MIN. AND 10' LONG, MIN. (TYP. 2) ,yL.~\ I ', ~EXISTINC MONOPOLE ~ GROUND RING (APPROXIMATE - LOCATION) (V.I.F.) AGROUND BAR 5 y AT BOTTOM OF MONOPOLE E03 E03 BOND TO EXISTING GROUND RING (V.I.F.) PROVIDE ~2 AWG GROUND LEAD FOR PROPOSED EQUIPMENT CABINET TO PROPOSED GROUND BAR ROUND GPS AMENNA SCHEMATIC GROUNDING PLAN n SCALE: N.T.S. ~ I GROUNDING LEGEND ,,,~,,,~, GROUND BAR ------- GROUND COPPER WIRE, SIZE AS NOTED ~- MECHANICAL GROUND CONNECTION ~' Dewberry® Dewberry-Goodkind, Inc, 280 SUMMER ST. 10TH FLOOR FAX:817.595.3310 ® 5/8"X10' COPPER CLAD STEEL GROUND ROD ~- EXOTHERMIC (CADWELL) CONNECTION - - - EXISTING GROUND RING {V.I.F.) 327 KING STREET SITE N0. SPMA0050 327 KING STREET NORTHAMPTON, MA 01060 t COMMUNICATIONS SAN ANTONIO, TX 76215 D 10/02/08 -ISSUED FORCONSTRUCTION ROM GHN PPB B D9/22/OB ISSUED FOR REVIEW ROM GHN PPB A 09/02/OB ISSUED FOR REVIEW ROM GHN PPB AS SHOWN I~DESIGNED BY: ROM ~ DRAWN BY: MR GROUNDING GENERAL NOTES 1. ALL DOWN CONDUCTORS AND GROUND THE RING CONDUCTOR SHALL BE ~2 AWG, SOLID, BARE, TINNED COPPER, UNLESS OTHERWISE NOTED. ALL CONNECTIONS TO GROUND RING SHALL BE EXOTHERMICALLY WELDED. CONDUCTOR SHALL BE AT A MINIMUM DEPTH BELOW GRADE OF 18 INCHES OR i0 LEDGE. MINIMUM BEND RADIUS SHALL BE 8 INCHES. CONDUCTOR SHALL BE AT LEAST 24 INCHES FROM ANY FOUNDATION, UNLESS OTHERWISE NOTED. 2. GROUND RODS SHALL BE 5/8" DIAMETER COPPER CLAD, HARGER, T&B, ERICO, OR EQUNALENT. TOP OF ROD SHALL BE A MINIMUM OF 18" BELOW GRADE. IF LEDGE IS ENCOUNTERED, INSTALL GROUND ROD AT AN ANGLE. ELECTRICAL METER GROUND ROD EXCEPTED. 3. WHERE MECHANICAL CONNECTIONS ARE SPECIFIED, BOLTED, COMPRESSION-TYPE, CLAMPS~OR SPLIT-BOLT TYPE CONNECTORS SHALL BE USED. 4. GRIND OFFGALVANIZING IN AFFECTED AREA. EXOTHERMICALLY WELD j2 CONDUCTOR AT 6" A80VE GRADE OR FOUNDATION, WHICHEVER IS HIGHER. COLD-GAIN AFTER. EXOTHERMICALLY WELD OTHER~END TOGROUND RING. 5. INSTALL GROUNDING KITS AT ANTENNA CENTERLINE, AND TOWER EXff POINTS. GROUND COAX LINES. EXOTHERMICALLY WELD {f2 DOWN CONDUCTOR TO PLATES, RUN DOWN TOWER, AND TIE INTO GROUNDING SYSTEM. 6. ALL GROUNDING WORK SHALL COMPLY WITH POCKET COMMUNICATIONS CONSTRUCTION COMRACT STANDARDS. FOLLOWING COMPCLl10N OF WORK, GROUND SYSTEM MUST BE TESTED AND SHALL HAVE A RESISTANCE OF 5OHM5 ORIESS SUMMR AN INDEPENDENT "FALL POTENTIAL" TESTING REPORT. 7. ALL GROUNDING CONDUCTORS ON EXTERIOR WALL OF SHELTER SHALL BE INSTALLED IN 3/4" SCH 40 PVC CONDUff TO 12" BELOW GRADE. ATTACH PVC WRH GALVANIZED 'C" CLAMPS. 8. CONTRACTOR SHALL HAND-DIG IN AREAS AROUND EXISTING UTILffIES. 9. NOTIFY CONSTRUCTION ENGINEER IF THERE ARE ANY DIFFlCULTIES INSTAWNG GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS. 10. GROUNDING RING IS SHOWN AS SCHEMATIC 9NLY. R IS DESIGNED WITHOUT BENEFIT OF RESISTIVITY TESTING AND ODES NOT NECESSARILY REPRESEM A GROUNDING SYSTEM TO MEET ANY SPECIFlC GROUND RESISTANCE 11. PRIOR TO POURING CONCRETE, ALl REBAR LOCATED NEAR THE BOTTOM OF THE FOUNDATION SHALL BE BONDED TOGETHER TO FORM A SINGLE GROUNDING ELECTRODE, BY STEEL TIES OF OTHER EFFECTIVE MEANS APPROVED BY NEC 2005 AND STRUCTURAL ENGINEER, AND BONGED TO THE GROUND RING AS DETAILED IN THESE PLANS. (INSPECTION MAY BE REQUIRED -PRIOR TO POURING CONCRETE AND MUST BE'COORDINATED'BY CONTRACTOR.) 12. IN ACCORDANCE WfiH NEC 2005 REQUIREMENTS, ALL GROUNDING ELECTRDOES PRESENT ON SITE SHALL 8E BONDED TOGETHER '(REFERENCE 2005 NEC ARTICLE 250.50). ' o~~~pa~H OF ~~s`P9 - cy ~~ I~ADFOROa. O ~~ ~ L ~.3~66 , HALF SIZE PRINT THIS DRAWING 15 ~SCALEABLE AT HALF THE NOTED SCALE POCKET COMMUNICATIONS SAN ANTONIO, TX 78215 • ~ SCHEMATIC GROUNDING PLAN > DEWBERRY ND. JOB N0. DRAWING 50014749 50014805 5PMA00° FlN z;Z goy m~ ~n ISO a o ~ n r CADWELD 5/B"0x10'-D" LONG L~2 AWG SOLID TINNED (MIN) COPPER COPPER GROUND WIRE CUD GROUND ROD NOTES: 1. CADWELD TO GROUND RING AFTER GROUND ROD HAS BEEN DRIVEN INTO PUCE. 2. FROST LINE TO DE VERIFIED. GROUND ROD ~ SCALE: N.T.S. ( (8) IF, ND: 1. INSUUTED BARE TINNED COPPER GROUND BAR KR WITH WALL BRACKETS, 1/4"z2"z10", ANDREWS GROUND BAR BUSS KR OR APPROVED EQUAL 2. (2) INSUUTORS (INCLUDED) 3. (Z) 1/2" LOCKWASHERS (INCLUDED) 4. (2) WALL MOUNTING BRACKET (INCLUDED) 5. (2) 1/2-13 X 1" H.H.C.S. (INCLUDED) 6. (2) 1/2-13 X 7/B' H.H.C.S. (INCLUDED) GROUND BAR PLATE (TYP.) n SCALE: N.T.S. ~ ~~ Dewberry® Dewberry-Goodkind, Inc, 280 SUMMEfl ST. 10TH FLOOq BOSTON, MA 07210' PHONE:017.696.3900 FA%:817.686,3310 1/4'- UNC X 1/2" BOLT (C.U.) DOUBLE BOLT GROUND LUG NUT k WASHERS (ttP.) ~'2 INSUUTED GREEN STRANDED TAP (GU.) EQUIPMENT CONNECTION TO EQUIPMENT DETAIL n SCALE: N.T.S. ~ L ANTENNA OUTLINE TYPICAL CIGdt 1_ JUMPER ,JUMPER 2 AWG DCW 0 CIGBE (ttP.) ELEYdIIDfI GROUND LUG TO TOWER ANTENNA MOUNT GROUNDING DETAIL 6 SCALE: N.T.S. •TYPE GeR-TC CLAMP - OR CADWELD TO MAST TO ANTENNA m ~ AMENNA GROUND BAR ~70P OF MONOPOLE SEE NOTE 1. STANDARD GROUND KR {ttPY ""' GROUND LUG 512E 8 AWG STRANDED Cu ANTENNA GROUND BAR WIRE WRH GREEN, 60DV, BOTTOM OF MONOPOLE THWN INSULATION (ttP} SEE NOTE 1. COAX CABLE (ttP FOA ALL)~,j) E%OTHERMIC WELD l1 SIZE 2 AWG Cu TO TRANSMISSION EQUIPMENT VIAL SOLID BNiE TINNED TRAY OR ICEBRIDGE COPPER WIRE MONOPOLE FOUNDATION ~ IZE 2 AWG BCW SOLID TINNED EXOTHERMIC WELD TO MONOPOLE BASE PUTE C{S?T~: DRNEN ROD 1. NUMBER OF GROUND 8AR5 MAY VARi DEPENDING ON THE TYPE OF MONOPOLE, ANTENNA LOCATION AND CONNECTION DRIEMATION. PRDWDE AS REQUIRED. MONOPOLE GROUNDING 9 SCALE: N.T.S. 327 KING STREET SITE N0. SPMA0050 327 KING STREET O COMMUNICATIONS 815 AVENUE 'B~ SAN ANTONIO, TX 78215 A STAR WASHER {TYPJ ~ FLAT WASHER (ttP.) 1/2"x1 1/2' HEK BOLT STNNLESS STEEL HARDWPRE NUT (ttP.) 7W0 HOLE COPPER GROUNDING COMPRESSION TERMINAL GROUND BAR CABLE E%POSED BARE COPPER TD BE GROUND BAR GROUNDING CABLE KEPT TOABSOLUTE MINIMUM, NO - INSUUTION ALLOWED WRHIN THE COMPRESSION TERMINAL (TYPJ LF EVATION A SECTION 'A-A' NOTES. i. DOUBLING UP OR STACKING OF CONNECTIONS IS NOT PERMffTED 2. OXIDE INHIBRING COMPOUND TO BE USED AT ALL LOCATIONS. TYPICAL GROUND BAR MECHANICAL CONNECTION DETAIL 3 SCALE: N.T.S. , AMENNA CABLE WEATHERPROOFING KR- (SEE NOTE 3) CABLE GROUND KR p6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR) (SEE NOTE 1 & 2) E.----~ 1 z" TO 24" N NOTES; i. 00 NOT INSTALL CADLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. GROUNDING HIT SHALL BE ANDREW SUREGROUND TYPE KIT WTfH TWO-HOLE LUG. 3. WEATHER PROOFING SHALL BE ANDREW TWD-PART TAPE SUPPLIED WITH KR. COLD SHRINK SHALL NOT BE USED. CONNECTION OF CABLE GROUND KIT TO ANTENNA CABLE DETAIL n SCALE: N.T.S. ~ ~ PANEL 5AFEtt METER SOCKET/MAIN DISCONNECT AT METER RACK {BY CONTRACTOR) AND INSTALL LONG SHANK LOCK ON ARM i0 PREVENT OF TAMPERING. SOLID TINNED COPPER ITINUOUS TO GROUND RING ~ I ~ ~° CONNECT TD GROUND RING COPPERCIAD STEEL GROUND ROD 5/8"0 x 10'-0" LONG 1 ~-0" METER SOCKET GROUNDING SCALE: N.T.S. NTO ANIjTENNA~S . WFATHERPRODFlNG RX2 (7X1/RX1 KR (TYP.) }1(((~$~( ANDREW'SUREGROUND COAX JUMPER (TYP.) TYPE KR (TYP.) CONNECTOR WEATHERPROOFING KR (ttP.) ANTENNA CABLE TO BTS EQUIPMEM (TYP.) ~6 AWG AMENNA GROUND BAR, BONGED DIRECTLY TO TOP OF TOWER NOTES. 1. INSTALL GROUND KITS a TOWER TOP, BASE AND AT BTS WTM GROUND BARS AT EACH LOCATION. CONNECTION OF GROUND WIRE TO GROUNDING BAR DETAIL n SCALE: N.T.S. ~ ISSUED FOR CONSTRUCTION ISSUED FOR REVIEW ISSUED FOR REVIEW AS SHOWN ~ DESIGNED BY: ROM .~ DRAWN BY: MR P~~µ oF,~gs . ~~ Ora `~'~, HALF SIZE PRWT f ~4DF~D~ ~ .THIS DRAWING IS SCALEABLE T HALF THE NOTED SCALE ' m o ELLS A 1 U (~' y ~ 6° Alo.3 POCKET COMMUNICATIONS SAN ANTONIO, TX 78215 ~9SK~M9L ~ GROUNDING DETAILS ~ . DEWBERRY N0. JOB N0. DRAWPIG NUMBER RE _ 50014749 50014805 SPMA0050-E03 ~a"x, GSA