PHEC-3603 325 Kennedy Rd - projected (AE base)Home Energy Rating Certificate Rating Date: 2024-07-31
Projected Report Registry ID: 'NER HOUSE
— iWT00fcsuLnW.
Based on Plans Ekotrope ID: d1WbwR82
Your Home's Estimated Energy Use:
Use [MBtu]
Annual Cost
Heating
15.2
$1,052
Cooling
0.3
$20
Hot Water
2.4
$166
Lights/Appliances
18.1
$1,254
Service Charges
$84
Generation (e.g. Solar)
0.0
$0
Total:
36.0
$2,576
HERS Index
Horne Feature Summary:
More E—Sy
Home Type:
Single family detached
lsa
Model:
NIA
Existing
140
Community:
NIA
Homes
130
Conditioned Floor Area:
2,240 ft3
7m
Number of Bed rooms:
3
Reference
10
Primar Heatin System:
Y 9 Y
Air Source Heat Pump Electric•9.5 HSPF2
P '
Home
1fl0
PrimaryCoo Iing System:
Air Source Heat Pump Electric • 195EER2
Primary Water Heating:
Residential Water Heater • Electric • 3.55 UEF
HouseTghtness:
3 ACH50
6o
Ventilation:
82 CFM • 50 Watts • ERV
so 4ft
Duct Leakage to Outside:
10 CFM @ 25Pa (0.451100 ftJ
40
Above Grade Walls:
R-27
w This Hone
Ceiling:
Attic,R-63
�a
Window Type:
U-Value: 0.28, SHGC:0.25
Zero Energy
Home
1�
❑
Foundation WaI Is:
R-15
616i] RFSM
LessSnf gy
Framed Floor:
NIA
This home meets or exceeds the
criteria of the following:
Massachusetts Stretch Code
2021 International Energy Conservation Code
Rating Completed by:
Energy Rater: Rachel BaIon
RESNETID:1726523
Rating Company: Power House Energy Consulting
PO Box 9571, North Amherst, MA 01059
(413) 835-5162
Rating Provider: Energy Raters of Massachusetts
2 Woodlawn Street Amesbury, MA 01913
978-270-3911
f�
F �395e-ram
c
Rachel Balon, Certified Energy Rater
Digital ly signed: 12/18/24 at 9:36 AM
Building Specification Summary
Property
325 Kennedy Rd
Northampton, MA 01053
PHEC-3603 325 Kennedy Rd
projected (AE base)
Building Information
Conditioned Area [ft21
Conditioned Volume [ft31
Thermal Boundary Area [ft21
N umber Of Bedrooms
Housing Type
organization
Power House Energy Consul
Rachel Balon
Builder
Chris Bloom
2,240.00
18,596.60
4,497.78
3
Single family detached
Building Shell
Ceiling w/Attic I R63,CE17"8-16; U-0.016
Vaulted Ceiling I None
Above Grade Walls I R21,FG2,6-16,+6 (ISO); U-0.044
Found. Walls I R15, XPS; R-15
Framed Floors I None
Slabs Uninsulated; R-0
Mechanical Systems
Heating
Cool i ng
Water Heating
Programmable Thermostat
Ventilation System
Whole House Fan
Lights and Appliances
Percent Interior LED
Percent Exterior LED
Refrigerator (kWh/yr)
Dishwasher Efficiency
Ceiling Fan
Inspection Status
Results are projected
Rating
HERS ERI 45
HERS ERI w/o PV 45
rj
POWER HOUSE
FneecrconsuLnnc
Windows (largest) I U-Value: 0.28, SHGC: 0.25
Wi ndow / Wa I I Ratio 10.17
Window/ Floor Ratio 10.10
Infiltration 13 ACH50
Duct Lkg to Outside 110 CFM @ 25Pa (0.45 / 100 e)
Total Dud Leakage 180 CFM @ 25Pa (Past -Construction)
Air Source Heat Pump- Electric • 9.5 HSPF2
Air Source Heat Pump- Electric • 19 SEER2
Residential Water Heater • Electric • 3.55 UEF
Yes
82 CFM - 50 Watts • ERV
NIA
100%
Clothes Dryer Fuel
100%
Clothes Dryer CEF
650.0
Clothes Washer LER (kWh/yr)
270 kWh
Clothes Washer Capacity
None
Range/Oven Fuel
Electric
3.5
152.0
4.2
Electric
Ekotrope RATER - Versian 4.2.2.3539
All results are based on data entered byEkotrope users. Ekctropedisclaims all liabilityfnrthe information shown on this report