Loading...
37-064 (19) 149 EASTHAMPTON RD BP-2000-0750 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 37-064 CITY OF NORTHAMPTON Lot: -001 Permit Building Category:NEW COMMERCIAL ACCESSORY BUILDING BUILDING PERMIT Permit# BP-2000-0750 Project# JS-2000-1 397 Est.Cost: $275000.00 Fee: $2016.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: 5B Contractor: License: Use Group: SI MORTON BUILDINGS INC 068650 Lot Size(sq. ft.): 451717.20 Owner: PHILLIPS WILLIAM L Zoning: GI Applicant: MORTON BUILDINGS INC AT: 149 EASTHAMPTON RD Applicant Address: Phone: Insurance: 563 SOUTHAMPTON RD (413) 562-7028 Workers Compensation WESTFIELDMA01085-1329 ISSUED ON:3/6/00 0:00:00 TO PERFORM THE FOLLOWING WORK:CONSTRUCT (2) COLD STORAGE WAREHOUSES - 60' X 168' POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Inspector of Buildings Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Rough Frame: Gas Fire Department Fireplace/Chimney: Rough: Oil: Insulation: ----- Final: Smoke: 1i(' 21,.00-1. THIS PERMIT MAY BE REVOKED BY THE CIT OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULA ONS. Certificate of Occu anc Si nature: Fee Type: Receipt No: Date Paid: Check No: Amount: Building 3/6/00 0:00:00 10798 $2016.00 212 Main Street, Phone(413)587-1240, Fax: (413)587-1272 Building Commissioner-Anthony Patillo ✓.:.. .. File#MP-2000-0023 APPLICANT/CONTACT PERSON Berkshire Design ADDRESS/PHONE 4 Allen Place 582-7000 PROPERTY LOCATION 149 EASTHAMPTON RD MAP 37 PARCEL 064 ZONE GI THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED QUT Fee Paid 1/? ` /c) Building Permit Filled ou J Fee Paid Typeof Construction: ADD(2)NEW 60 X 168 STORAGE BUILDINGS New Construction Non Structural interior renovations A.:lition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION: A ved as presented/based on information presented. Denied as presented: ro � L Specia�l Pi t and/or Site Plan Required under: § /0./7""'3 v PLANNING BOARD ZONING BOARD Received&Recorded at Registry of Deeds Proof Enclosed Finding Required under: § w/ZONING BOARD OF APPEALS Received&Recorded at Registry of Deeds Proof Enclosed Variance Required under: § w/ZONING BOARD OF APPEALS Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health 1/Permit from Conservation C 'ssion 4/oi7C r C /,,,rL,v ....----- 2-c.--- - e-----1 / 9/747/ Signature of Building Official Date Note:Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. File#MP-2000-0023 APPLICANT/CONTACT PERSON Berkshire Design ADDRESS/PHONE 4 Allen Place BRYAN JEREB 582-7000 PROPERTY LOCATION 149 EASTHAMPTON RD MAP 37 PARCEL 064 ZONE GI THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM F LED OUT Building Permit Filled out Fee Paid Typeof Construction: ADD(2)NEW 60 X 168 STORAGE BUILDINGS New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION: Approved as presented/based on information presented. enied as presented: // Special Permit and/or Site Plan Required under: § AA) Y PLANNING BOARD ZONING BOARD Received&Recorded at Registry of Deeds Proof Enclosed Finding Required under: § w/ZONING BOARD OF APPEALS Received&Recorded at Registry of Deeds Proof Enclosed Variance Required under: § w/ZONING BOARD OF APPEALS Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation ission tiO77C QF /�T"4/7---- / Signature uilding Official Date Note:Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. , •. 10, l f Fi 1� ��o_ /pnna3 AUG � 71.999 ZONING PERMIT APPLICATION (§1.O . 2) f PTA �'STPE OR PRINT ALL INFORMATION 1. Name of Applicant: Bill Phillips / Phillips Enterprises Inc _ Address: 149 Easthampton Road , Northamptn[Telephone: ( 413) 586-5811.0 2. Owner of Property: Bill Phillip s Address: 11 Grandview Lane, Easthampton Telephone: (413) 529-0000 iM A, 01027 3. Status of Applicant: X Owner Contract Purchaser Lessee Other(explain): 4. Job Location: 149 Easthampton Road , NorthtmntQn Parcel Id: Zoning Map# Parcel# Q District(s): CY (TO BE FILLED IN BY THE BU LDING DEPARTMENT) 5. Existing Use of Structure/Property Industrial U s e 6. Description of Proposed Use/Work/Project/Occupation: (Use additional sheets if necessary): • Addition of 2 new 50 ' x168 ' storage buildings 7. Attached Plans: Sketch Olan X Site Plan Engineered/Surveyed Plans Answers to the following 2 questions may be obtained by checking with the Building Dept or Planning Department Files. S. Has a Special PermitNariance/Finding ever been issued for/on the site? NO DONT KNOW X YES IF YES,date issued: IF YES: Was the permit recorded at the Registry of Deeds? f r NO DONT KNOW X YES IF YES: enter Book Page and/or Document# 9. Does the site contain a brook,body of water or wetlands? NO DON'T KNOW YES X IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained X Obtained ,date issued: (FORM CONTINUES ON OTHER SIDE) • The Berkshire Design Group, Inc. Landscape Architecture Civil Engineering Bryan D.Jereb Planning Landscape Architect Urban Design Tel.413-582-7000 4 Allen Place Fax 413-582-7005 Northampton,MA 01060 bryan@berkshiredesign.com it • 10. Do any signs exist on the property? YES X NO IF YES,describe size,type and location: P r e-e x i s t i n g e n t r y s i g n • Are there any proposed changes to or additions of signs intended for the property?YES NOS(_ IF YES,describe size,type and location: 11 - ALL INFORMATION MUST BE COMPLETED, or PERMIT CAN BE DENIED DUE To LACK OF INFORMATION_ n,;, col. to b. Si "t by Cho Building Departaooc Required Existing Proposed By Zoning Lot size 393 , 913 SF 393 , 913 SF �J Frontage / P ° 822. 16 822. 16 Setbacks - frnnt . 18' * 331 ** a - side L:24. 2 'R: 416 ' L:24. 2 R:185 ' /%5 - - rear O 88 ' 88 ' Building height 28' Bldg Square footage `_ 47 ,703 SF 67 ,863 SF to %Open Space: • 317, 147 SF 289 , 248 SF (Lot area minus bldg Or or02 /� speved parking) 80% 73% C,� # of Parking Spaces 15 16 #'Hof Loading Docks 2 4 Fill: 1120 C .Y. '-vol-ume--& location) , Foundation/Slab base 13 . Certification: I hereby certify that the information contained herein • G is true and accurate to the best of my knowledge. • DATE: 44-J/q" APPLICANT'S SIGNATURE07/• NOTE: issuanoe of a zoning ermit does not relieve an antes bard to oom Witt} &ill P PP PIY .. zoning requirements and obtain all required permits from the Board of Health. Conservation Commission, Department of Publics Works and other applicable permit granting authoritioa. * Pre-existing office FILE bldg. _ ** Proposed Bldg. _ — _ 'C > .a 70 'V C i . . _ !j, rr, o = .„..-- ,r, , ). 1.,-:: =1 p r z N of 1 =i z ..,,, �tri 5 3 cS. n O et „ x m rt,,,L, .... 1„.. , ,, �orri. , „,.„ i .... 9 Zoning Miscellaneous Additions.Repairs,Alterations.etc. Tel.No. Alterations ik.444) NORTHAMPTON, MASS. 19 Additions APPLICATION FOR PERMIT TO ALTER Repair _ Garage :�: /Location / �J'l 6�.S�/`( "1,070st/ XfJ Nv�77-0'y,l o.t/ Lot No. �wn is name W'i L 6 (4-' P(-7(< C i,S `Address /`/P• •C--} ri4F/ffiy/eloa./ (e/.) /I 4m/t" 3 uilder's name /`/O rat/ bait-D/PC S /tiC Address 3 5007--/y fAbofiN 4 42 iF/66o th. C / ooc' �s.Construction Supervisor's License No. 06,E. `J o �iration Date /� Z- Z COL COCoiv1/C-rei — W/e1-�F,//oc'SSS %oi/!-L Zr',2oe�a 7Cr 2 �!1�ddition 5. Alteration 6. New Porch 7. Is existing building to be demolished? 8. Repair after the fire 9. Garage No.of cars Size 10. Method of heating 11. Distance to lot lines 12. Type of roof 13. Siding house ✓1.E. Estimated cost:- sal* 'Z 7 S p 0 O Th undersigned certifies that the above statements arc true to the best of his. nowledg and belief. • —X• /946&j — Signature of responsible app,icont Remarks File#BP-2000-0750 APPLICANT/CONTACT PERSON MORTON BUILDINGS INC ADDRESS/PHONE 563 SOUTHAMPTON RD (413)562-7028 PROPERTY LOCATION 149 EASTHAMPTON RD MAP 37 PARCEL 064 ZONE G1 THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid /0,97 ,$ ,O/(p Tvpeof Construction: CONSTRUCT(2)COLD STORAGE WAREHOUSES-60'X 168' New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 068650 3 sets of Plans/Plot Plan ,g �, THE 1�LLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION: Approved as presented/based on information presented. Denied as presented: Special Pe it and/or Site Plan Required under: § PLANNING BOARD ZONING BOARD Received& Recorded at Registry of Deeds Proof Enclosed Finding Required under: § w/ZONING BOARD OF APPEALS Received& Recorded at Registry of Deeds Proof Enclosed Variance Required under: § w/ZONING BOARD OF APPEALS Received& Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Com ' on ,/ /d __.,1. 2/00 Signature o Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. L �' R n tl`! ,-, µICS� I!I2000 1-MAR-2000 09:44:32 Hampshire County Registry of Deeds Receipt No: 122843 Marianne L. Donohue, Resister of Deeds 33 King Street Northampton. MA 01060-3298 Name: WILLIAM PHILLIPS Addr: 149 EASTHAMPTON RD NORTHAMPTON MA 01060 Receipt Type: OR Payment Total Pages: 0003 Fees Taxes Fee: $ 10.00 Cash: $ 10.00 $ 0.00 Tax: $ 0.00 Check: $ 0.00 $ 0.00 Misc: $ 0.00 Charge: $ 0.00 Charge Code: Comment: PLANNING BOARD DECISION Receipted By: DIANE Status: PAID DOCUMENTS: 992003992 to 992003992 Type Page Doc Mref Considers Record Fee Excise Tax Stat Misc Fee Record Date Document* Book/No/Page Status MIS3 003 0001 0000 0.00 10.00 0.00 0.00 1-MAR-2000 09:43 992003992 OR /5893/0102 INIT Page 0001 of 0001 MORTON BUILDINGS, INC. Excellence — Since 1903 • RICHARD GALLUP Sales Consultant 563 Southampton Rd Westfield.MA 01085-13?R RESIDENCE FAX r iF-F irG (413)337-5367 (413)568-5102 (413)562-7028 • 1 2 � U� � \-- , \S.1 ..1._: 2 8 I.__..- \ File No. �'&6 7sv„,,„0,,, 0_ _KING PERMIT APPLICATION (S10 . 2) .'� �' _��~ PLEASE TYPE OR PRINT ALL INFORMATION 1. Name of Applicant: W I Li.( A t` IPti I LL l p S Address: ( T 9 E v ST H-{ t P o' ( `o Telephone: `( (3 " G'8 (.^ S 3 G 0 2. Owner of Property: Got L L (A 1-1L . P� I C.L I to Address: 1 q 9 E 1 r( 411+' (20 Telephone: T ( ';- gC,' S Z-6, 0 3. Status of Applicant: X Owner Contract Purchaser Lessee Other(explain): _ 4. Job Location: 1 4 l E S 1 rt it1!Prot' 0 Parcel Id: Zoning Map# 0 7 Parcel# 6 r District(s): G%_ (TO BE FILLED IN BY THE BUILDING DEPARTMENT) 5. Existing Use of Structure/Property EN/oi ( F,tc-O 74- el-p/C c-- f fi/F' 6L0C . 6. Description of Proposed Use/Work/Project/Occupation: (Use additional sheets if necessary): Co NSA 6,,ci (z Coco 37-0g/f '6 G6i11 7-74a)sez-_ 60 (>/ ' S 7. Attached Plans: Sketch Plan - Site Plan v Engineered/Surveyed Plans Answers to the following 2 questions may be obtained by checking with the Building Dept or Planning Department Files. 8. Has a Special PermitNariance/Finding ever been issued for/on the site? NO DON'T KNOW YES IF YES,date issued: /1(/`?7?9 IF YES: Was the permit recorded at the Registry of Deeds? NO DON'T KNOW /� YES IF YES: enter Book Page and/or Document# 9. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW YES IF YES,has a permit been or need to be obtained from the Conservation Commission?IV-Needs to be obtained Obtained ,date issued: Alo 4-/ c• o iffy (FORM CONTINUES ON OTHER SIDE) 1 • i . 10. Do any signs exist on the property? YES NO IF YES,describe size,type and location: V t L.G oRi2D Perko ( 8 / Y /(a N EA.2_ S E ti-ru.r S PK 0IPC-R ' Are there any proposed changes to or additions of signs intended for the property?YES NO IF YES,describe size,type and location: 11. ALL INFORMATION MUST BE COMPLETED, or PERMIT CAN BE DENIED DUE TO LACK OF INFORMATION. This colnffi to be filled in by the Building Department Required 1 Existing Proposed By Zoning Lot size 3g31 1/3t(i_t- ? •3) ?/3 j F _ t i Frontage g Z 2 . 1 (0 g 22 r/ L Setbacks - front _3 3 ' d I t / / - side L: 2-5 R• 24,2 L: /7? R: ZAL /6 - rear ge / 23 ' 0 Building height 2 g ' 2 8 ' • Bldg Square footage '94,i 94C p� Z 0) oft %Open Space: �` (Lot area minus bldg 9 5 _ &paved parking) o /7 0 # of Parking Spaces 2,0 0 . #- of Loading Docks z Fill: ?(vo1.-ume -& location) l fd CO. 7"C 13 . Certification: I hereby certify that the information contained herein is true an accurate to the best of my knowl ge. DATE: 27-- z" ��' ' APPLICANT's SIGNATURE -----X ' _✓ ����--!'�' NOTE: Issuanoe of a zoning permit does not relieve an applioant's burden to oomply with all zoning requirements and obtain all required permits from the Board of Health, Conservation Commission, Department of Publio Works and other applioable permit granting authorities. FILE I • Preliminary Plan Review Checklist City of Northampton Date submitted : �,C6 2.-.0/ epocn Address: /'/9 . 4qi17.(/ Map 3 ? Parcel C'I Zone (;L Lot size: /, 3l 91 3 Edition of Building Code in force: DT's' Building Permit # b P- 2.c0 o - cV,,s O Applicant: no'ro-.../ /tic. Owner or Authorized Agent : (.4.ijL4/9/P) ���,cc✓�S - 1. Use Group : 2. Building Type of Construction : ts� 3. Square footage of proposed construction: 2 so.,.opuGs 4. Height of proposed construction 5. Site plan required y- : Surveyed: /FS 6. Fire protection Signaling Required: Suppression Required Alarm Notification Required : Exterior Wall fire resistance rating : 7.Conservation (Wetlands) : .es X FrvE.D 8.Change in Use 9.AAB Requirements : ,vO 1 o.Plumbing (fixture count change required) : .v 11.Controlled Construction (116) 12. Local Zoning Ordinance restrictions : 13. Plans Stamped by : 14. Energy Conservation: u07 Inspector: Ti�.o /0, Date reviewed: j,/000 Pass )( Fail Hold for more information Comments: ,4y4 if/ Gi-we•f4%l°4S 780 CMR: STATE BOARD OF BUILDING REGULATIONS AND STANDARDS THE MASSACHUSETTS STATE BUILDING CODE Table 503 HEIGHT AND AREA LIMITATIONS OF BUILDINGS Height limitations of buildings(shown in upper figure as stories and feet above grade plane)°,and area limitations of one-or two-story buildings facing on one street or public space not less than 30 feet wide (shown in lower figure asarea in square feet per floor°).See Note a. - Table notes appear immediately following table. N.P.=Not Permitted: N.L.=Not Limited Type of Construction Noncombustible/ Noncombustible Combustible USE GROUPS Combustible Type I Type 2 Type 3 Type 4 Type 5 Protected Unpro- Pro- Unpro- Heavy Pro-Note b Unpro- Protected tected tected tected timber tected tected Note a IA lB 2A 2B 2C 3A 3B 4 5A 5B A-I Assembly;theaters N.L. N.L. 5 Si 65'3 Si 40'2 St.30' 3 St 40' 2 St.30' 3 St.40' 1 St 20' 1 St.20' 19.950 13,125 8.400 11.550 8.400 12.600 8.925 4,200 A-2 Assembly; night clubs and N L N.L. 3 St.40'2 Si 30' I Si 20' 2 Si 30' 1 Si 20' 2 St 30' I Si 20' 1 St 20'• similar uses 7,200 5,700 3,750 2,400 3,300 2.400 3.600 2,550 1.200 A-3 Assembly;lecture halls.recre- 5 St 65'3 Si 40'2 Si 30' 3 St.40' 2 St.30' 3 St 40' 1 St.20' 1 St.20' ation centers, terminals, restaurants N.L. N.L. 19,950 13,125 8,400 11,550 8,400 12,600 8,925 4,200 other than night clubs A-4 Assembly,churches N.L. N.L. 5 St.65'3 St.40'2 St 30' 3 St 40' 2 Si 30' 3 St.40' 1 Si 20' 1 Si 2071 Notec 34,200 22,500 14,400 19,800 14.400 21,600 15,300 7,200 B Business N.L. N.L. 7 St 85'5 Se 65'3 Si 40' 4 St 50' 3 St 40' S St 65' 3 St 40' 2 St.30' 34,200 22,500 14,400 19,800 14,400 21.600 15.300 7.200 5 St.65'3 St 40'2 St 30' 3 St.40' 2 St 30' 3 St 40' 1 St.20' 1 St.20' E Educational Note c N.L. N.L. 34,200 22,500 14,400 19,800 14,400 21,600 15,300 7.200 Noted Note d• F-I Factory and industrial N.L. N.L. 6 St 75'4 Si 50'2 St.30' 3 St 40' 2 St.30' 4 Si 50' 2 St 30' 1 St.20' Moderate 22,800 15,000 9,600 13,200 9,600 14,400 10,200 4,800 F-2 Factory and Industrial 7 St 85'5 St 65'3 St 40' 4 St.50' 3 St.40' 5 St 65' 3 St 40' 2 St.30' low Note h N.L. N.L. 34,200 22,500 14,400 19,800 14,400 21.600 15,300 7.200 H-1 High hazard, 1 St.20' 1 St.20' 1 St 20' 1 St 20' 1 St 20' 1 St.20' I St 20' I Si 20' 1 St 20' N.P. detonaton hazards Notes e,i,k,l 16.800 14,400 11,400 7,500 4,800 6,600 4,800 7,200 5,100 H-2 High Hazard 5 St 65'3 Si 40' 3 St 40'2 St 30' I St 20' 2 St 30' I St 20' 2 St.30' 1 St.20' N.P. deflagration hazards Note e,i,j,l 16,800 14,400 11,400 7,500 4,800 6,600 4,800 7,200 5,100 H-3 High Hazard 7 Si 85'7 Si 85' 6 St 75'4 St 50'2 St.30' 3 St.40' 2 St 30' 4 St 50' 2 St.30' 1 St.20' physical hazards Note e,1 33.600 28,800 22,800 15,000 9,600 13,200 9,600 14,400 10,200 4,800 H-t High Hazard 7 St 85'7 St 85' 7 St 85'5 St 65'3 St 40' 4 St 50' 3 St 40' 5 St 65' 3 St 40' 2 St 30' health hazards Note e,1 N.L. N.L. 34,200 22,500 14,400 19,800 14,400 21,600 15,.00 7,200 I-I Institutional,residential care N.L. N.L. 9 St 100' 4 St.50'3 St.40' 4 St.50' 3 St.40' 4 St.50' 3 Si 40' 2 Si 35' • 19,950 13,125 8,200 11,550 8,400 12.600 8,925 4,200 1-2 Institutional,incapacitated 4 St 50'2 St 30' I St 20' 1 St 20' 1 St 20' I St.20' Note m N.L. N.L. 17,100 11.250 7,200 9,900 N.P. 10,800 7,650 N.P. I� Institutional.restrained N.L. N.L. 4 St 50'2 St 30' I St 20' 2 St 30' 1 St 20' 2 St 30' I St 20' N.P. 14,250 9,375 6,000 8,250 6,000 9,000 6,375 M Mercantile N.L. N.L 6 St.75'4 St.50'2 Si 30' 3 Si 40' 2 St.30' 4 Si 50' 2 St.30' 1 St.20' 22.800 15,000 9,600 13,200 9,600 14,400 10,200 4,800 R-1 Residential,hotels N.L. N.L. 9 St 100' 4 St 50' 3 St 40' 4 St 50' 3 St 40' 4 St.50' 3 St 40' 2 Si 35' 22,800 15,000 9,600 13,200 9,600 14.400 10,200 4,800 4St50' 4St50' 9 Si 100' 3 St.40' 3 Si 40' 4 St.50' 3 Si 40' 2 Si 35' R-2 Residential,multi-family N.L. N.L. 22,800 15,000 9,600 13.200 9,600 14,400 10,200 4.800 Note f Note f R-3 Residential, N.L. N.L. 4 St.50' 4 St 50'3 Si 40' 4 St.50' 3 St 40' 4 Si 50' 3 St.40' 2 Si 35" multiple single family 22.800 15,000 9,600 13,200 9,600 14,400 10,200 5 St.65'4 St.50'2 St.30' 3 St.40' 2 St.30' 4 St.50' 2 St.37°-I St_20'� S-1 Storage,moderate N.L. N.L. 19,950 13,125 8,400 11.550 8,400 12.600 8,9k.5 4200 S 2 Storage,low Note g N.L. N.L. 7 St 85'5 St.65'3 St.40' 4 St.50' 3 St.40' 5 St.65' 3 St 40 30' 34,200 22,500 14,400 19,800 14..400 21,600 15,300 7.200 'U Utility,miscellaneous N.L. N L. Notes applicable to Table 503: Note a. Sec the following sections for general exceptions to Table 503: 780 CMR 504.2 Allowable height increase due to automatic sprinkler system installation. 1 14 780 CMR-Sixth Edition 2/7/97 (Effective 2/28/97) 780 CMR: STATE BOARD OF BUILDING REGULATIONS AND STANDARDS THE MASSACHUSETTS STATE BUILDING CODE 780 CMR 505.0 MEZZANINES aggregate area of the enclosed space does not 505.1 General: A mezzanine or mezzanines in exceed ten. compliance with 780 CMR 505.0 shall be considered 2. A mezzanine having two or more means of a portion of the floor below.Such mezzanines shall egress is not required to be open to the room in not contribute to the building area as regulated by which the mezzanine is located,if at least one of 780 CMR -503.2. •Such mezzanines shall not the means of egress provides direct access to an contribute to the number of stories as regulated by exit from the mezzanine level. 780 CMR 503.3.The area of the mezzanine shall be included in determining the fire area. 780 CMR 506.0 AREA MODIFICATIONS 506.1 General:The provisions of 780 CMR 506.0 505.2 Area limitation: The aggregate area of a shall modify the area limitations of Table 503 mezzanine or mezzanines within a room shall not herein specified. exceed '/s of the area of that room. The enclosed /v 6 portions of rooms shall not be included in 506.2 Street frontage increase:Where a buil ing or determination of the size of the room in which th structure has more than 25% of the building mezzanine is located. In determining the allowabl perimeter fronting on a street or other unoccupied mezzanine area,the area of the mezzanine shall not space, the area limitations specified in Table 503 be included in the area of the room. shall be increased 2% for each 1%of such excess Exception:The aggregate area of mezzanines in frontage.The unoccupied space shall be on the same buildings and structures of Type 1 or 2 lot or dedicated for public use,shall notbe less_than construction for special industrial occupancies in 30 feet (9144 mm) in width and shall have access accordance with 780 CMR 503.1.1 shall no from a street by a posted fire lane not less than 18 exceed 2/3 of the area of that room. feet(5486 mm)in width. 505.3 Egress:Each occupant of a mezzanine shall 5063 Automatic sprinkler system: Where a have access to at least two independent means of building,other than those with an occupancy in Use i egress where such spaces require two means of Group H-I,H-2 or H-3,is equipped throughout with egress in accordance with 780 CMR 1017.2. Where an automatic sprinkler system installed in a stairway provides a means of exit access from a accordance with 780 CMR 906.2.1, the area mezzanine,the maximum travel distance required by limitation specified in Table 503 shall be increased 780 CMR 1017.2 shall be measured to the bottom of 20093 for one-and two-story buildings and 100% the stairway. for buildings more than two stories in height. 505.4 Openness: A mezzanine shall be open and 506.4 Multistory buildings: The area limitations unobstructed to the room in which such mezzanine for buildings two stories in height shall be the same is located except for walls not more than 42 inches as the area limitations provided in Table 503 for one- (1067 mrn)high,columns and posts. story buildings. In buildings over two stories in Exceptions height, the area limitations of Table 503 for one- I. Mezzanines or portions thereof are not required story buildings shall be reduced as specified in Table to be open to the room in which the mezzanines 506.4. are located,provided that the occupant load of the C 116 780 CMR-Sixth Edition 11/27/98