Loading...
NRHT-MA-01-SHELTER LOCATION_REV00_20241030© 2024 Microsoft Corporation © 2024 Maxar ©CNES (2024) Distribution Airbus DS © 2024 TomTom PROJECT LOCATION PROPOSED 4-4" BURIED CONDUITINSTALLATION, TO TURN 90 DEGREESAND TRAVEL UP WALL TO LOWERENTRY PORTS. SEE DETAIL B.PROPOSEDHANDHOLELOCATIONPROPOSED 1-4"ELECTRICAL CONDUIT.SEE DETAIL B.48"X48" HHPROPOSEDCOMMUNICATIONHUT LOCATION ONCONCRETE PAD1.0'APPROXIMATE EXTENT OFPROPOSED 20'x20' EASEMENTDETAIL ATOP VIEW OF EASEMENTSCALE 1" = 4'4'X5' CONCRETE PAD1-4" TEMPORARY AERIALPOWER DROP CONDUITDETAIL BNORTH WALL SIDE VIEW OF CONDUITS & METERSCALE 1" = 4'PROPOSED 2-4" TEMPORARY BURIED FIBERDROP CONDUITS, TO TURN 90 DEGREESAND TRAVEL UP WALL TO WEATHERHEAD.SEE DETAIL B.EXISTING 2" DIA ATS HOLE WALL ENTRY (DONOT DRILL OR PLUG EXISTING HOLE)17"X30"HHMETER12" SCH 40 PVCCAST @ 40" (TYP.)12 ENTRYPORT PANELPROPOSED 4-4" CONDUIT INSTALLATION, TO TURN 90DEGREES AND TERMINATE AT 48"X48" HAND HOLE.SEE DETAIL A.2-4" TEMPORARY FIBER DROP CONDUITLEADING TO HH. SEE DETAIL A.GENHVAC. SEE NOTE 1.PROJECT NOTES1.GENERATOR, METER, AND HVAC DIMENSIONSAND PLACEMENT NOT SHOWN TO SCALE. SEECELLSITE AND ROHN DRAWINGS FORDIMENSIONING AND STRUCTURE DETAILS.2.SEE CELLSITE AND ROHN DRAWINGS FORDIMENSIONING AND STRUCTURE DETAILS.3.CONTRACTOR TO INSTALL AERIAL DROPCONDUITS PER NESC CLEARANCE WITHWEATHERHEADS.PROJECT NOTES1.GENERATOR, METER, AND HVACDIMENSIONS AND PLACEMENT NOTSHOWN TO SCALE. SEE CELLSITE ANDROHN DRAWINGS FOR DIMENSIONINGAND STRUCTURE DETAILS.2-4" TEMPORARY FIBER DROP CONDUIT LEADING TO HH. TO TURN90 DEGREES AND TERMINATE AT 48"X48" HAND HOLE.1-4" TEMP AERIAL POWERDROP CONDUITAPPROXIMATE LOCATION OFELECTRIC METER. SEE NOTE 1.SET BACK10.0'12.0'4.0'5.0'20.0'20.0'11.0'1.0'3.0'4.0'1.0'HVACAPPROXIMATELOCATION. SEE NOTE 1.PROPOSED 1-4" ELECTRICAL CONDUIT. SEE DETAIL A. SHELTER LOCATION 187 LOCUST ST NORTHAMPTON, MA SITE LOCATION MAPSITE LOCATION MAP NOTE: CONTRACTOR TO CONTACT MASSACHUSETTS 811 BEFORE DIGGING. (1-888-344-7233) ISSUED FOR CONSTRUCTION = Appx. Project Location INDEX TO SHEETS SHEETS DESCRIPTION A1-A2 TITLE SHEET & GENERAL NOTES B1-B2 PROJECT PLAN VIEW C1 STANDARD CONSTRUCTION DETAILS APPROVED BY: SHEET: DATE DRAWN: PROJECT NUMBER: DRAWN BY:CHECKED BY: DESCRIPTION REVISIONS 04 07 05 06 08 09 10 11 DATE 00 01 03 02 REV BY TITLE: ENGINEER: FIBERHOOD: 921 WEST VAN BUREN, SUITE 100 CHICAGO, IL 60607 PHONE: (312) 432-0076 FAX:(312) 432-0231 STATE OF ILLINOIS, DEPARTMENT OF PROFESSIONAL REGULATION. LICENSE NO. 184-002308 A1 AJR NJF AJR 24-0404 10/30/2024 SHELTER LOCATION 10/30/2024 FOR CONSTRUCTION AJR PROPOSED FIBER - OPTIC INSTALLATION - CIVIL DESIGN 187 LOCUST ST NORTHAMPTON, MA N 275 WEST SERVICE RD SUITE O WRIGHT CITY, MO 63390 OWNER/DEVELOPER: HAMPSHIRE COUNTY NORTHAMPTON, MA 91 9 5 APPROVED BY: SHEET: DATE DRAWN: PROJECT NUMBER: DRAWN BY:CHECKED BY: DESCRIPTION REVISIONS 04 07 05 06 08 09 10 11 DATE 00 01 03 02 REV BY TITLE: ENGINEER: FIBERHOOD: 921 WEST VAN BUREN, SUITE 100 CHICAGO, IL 60607 PHONE: (312) 432-0076 FAX:(312) 432-0231 STATE OF ILLINOIS, DEPARTMENT OF PROFESSIONAL REGULATION. LICENSE NO. 184-002308 A2 AJR NJF AJR 24-0404 10/30/2024 SHELTER LOCATION 10/30/2024 FOR CONSTRUCTION AJR PROPOSED FIBER - OPTIC INSTALLATION - CIVIL DESIGN 187 LOCUST ST NORTHAMPTON, MA 275 WEST SERVICE RD SUITE O WRIGHT CITY, MO 63390 OWNER/DEVELOPER: GENERAL NOTES DEVELOPER: GATEWAY FIBER JASON WING (603) 812-1090 JASON.WING@GATEWAYFIBER.COM PROJECT MANAGER:HBK ENGINEERING, LLC ALEXANDRA RAY 2401 WALNUT ST. PHILADELPHIA, PA 19128 (760) 468-0044 ARAY@HBKENGINEERING.COM SECTION 1.0 SCOPE OF WORK 1.CONSTRUCTION OF ALL RELATED APPURTENANCES FOR FIBER OPTIC CABLE INSTALLATION. SEE PLANS FOR EXACT LOCATION, LENGTHS, QUANTITIES, AND DIMENSIONS OF PROPOSED IMPROVEMENTS. 2.THE CONTRACTOR SHALL PROVIDE ALL MATERIAL, EQUIPMENT, LABOR, INSTALLATION, RESTORATION, UTILITY RELOCATION CHARGES, JOB SITE DELIVERY COSTS TO COMPLETE THE DESCRIBED, OR ILLUSTRATED WORK, UNDER THIS CONTRACT. 3.ANY CHANGE-ORDER REQUEST MUST BE PRESENTED IN WRITING TO THE OWNER'S REPRESENTATIVE; AND APPROVED PRIOR TO PROCEEDING WITH THE REQUESTED CHANGE. DOCUMENTATION CONCERNING ANY AND ALL CHANGE ORDERS WILL BE REDUCED TO FORMAL RECORD, FILED WITH THE OWNER'S REPRESENTATIVE, AND BE MADE AVAILABLE FOR FUTURE REFERENCE. 4.THE ENGINEER WILL NOT BE RESPONSIBLE NOR ASSUME ANY LIABILITY FOR NEGLIGENT ACTS OR ERRORS OF OMISSIONS OF ANY CONTRACTOR, ANY SUBCONTRACTOR, OR ANY OF THE CONTRACTOR'S OR SUBCONTRACTORS' AGENTS OR EMPLOYEES OR ANY OTHER PERSONS (EXCEPT ENGINEER'S OWN EMPLOYEES) AT THE PROJECT SITE OR OTHERWISE PERFORMING ANY OF THE WORK OF THE PROJECT. ANY CONTRACTOR OR SUB-CONTRACTOR, AS WELL AS THE ENGINEER, WILL BE RESPONSIBLE FOR HIS OWN SAFETY PROGRAM. NEITHER THE PROFESSIONAL ACTIVITIES OF THE ENGINEER, NOR THE PRESENCE OF THE ENGINEER OR HIS OR HER EMPLOYEES AND SUBCONSULTANTS AT THE CONSTRUCTION SITE, SHALL RELIEVE ANY CONTRACTOR OF HIS OR HER OBLIGATIONS, DUTIES AND RESPONSIBILITIES INCLUDING, BUT NOT LIMITED TO, CONSTRUCTION MEANS, METHODS, SEQUENCE, TECHNIQUES OR PROCEDURES NECESSARY FOR PERFORMING, SUPERINTENDING OR COORDINATING ALL PORTIONS OF THE WORK OF CONSTRUCTION IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND ANY HEALTH OR SAFETY PRECAUTIONS REQUIRED BY ANY REGULATORY AGENCIES. THE ENGINEER AND HIS OR HER PERSONNEL HAVE NO AUTHORITY TO EXERCISE ANY CONTROL OVER ANY CONSTRUCTION CONTRACTOR OR OTHER ENTITY OR THEIR EMPLOYEES IN CONNECTION WITH ANY HEALTH OR SAFETY PRECAUTIONS. 5.ALL MAKE READY ADJUSTMENTS ARE PROPOSED PER MAINTAINING NESC GUIDELINES. SECTION 2.0 MATERIALS 1.ALL MATERIALS INSTALLED WITHIN THE LIMITS OF THIS PROJECT SHALL BE IN CONFORMANCE WITH STANDARD RECOMMENDATIONS OF THE NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION AND AMERICAN NATIONAL STANDARDS INSTITUTE. 2.ALL STRANDS (MESSENGER WIRES) SHALL BE 1 4" (UNLESS NOTED OTHERWISE): 3.JOB SITE MATERIAL WILL BE DELIVERED TO, AND MAINTAINED AT THE STREET WORK AREAS IN A WELL MANAGED MANNER, TO MINIMIZE CONGESTION OR INCONVENIENCE TO OTHER WORKERS, OR CONTRACTORS WORKING UNDER ALTERNATE PERMITS. SECTION 3.0 GENERAL NOTES 1.THESE NOTES SHALL BE CONSIDERED A PART OF THE WRITTEN SPECIFICATIONS. 2.THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 3.PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTORS SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE IMPLEMENTATION ENGINEER AND ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH THE WORK. 4.THE CONTRACTOR SHALL RECEIVE, IN WRITING, AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS. 5.THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY INDICATED OTHERWISE OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 6.ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 7.THE GENERAL CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, USING THE BEST SKILLS AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTIONS MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATION ALL PORTION OF THE WORK UNDER THE CONTRACT INCLUDING CONTACT AND COORDINATION WITH THE IMPLEMENTATION ENGINEER AND WITH THE LANDLORD'S AUTHORIZED REPRESENTATIVE. 8. SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH U.L. LISTED FIRE CODE APPROVED MATERIALS 9.PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE PROJECT AREA DURING CONSTRUCTION. 10.DETAILS ARE INTENDED TO SHOW END RESULTS OF DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUITE JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. 11.THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, PAVING, CURBS, VEGETATION, GALVANIZED SURFACE, ETC., AND UPON COMPLETION OF WORK REPAIR ANY DAMAGE THAT OCCURRED DURING CONSTRUCTION TO THE SATISFACTION OF OWNER/DEVELOPER AND AFFECTED PROPERTY OWNER. 12.KEEP GENERAL AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS, RUBBISH AND REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY. LEAVE PREMISES IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST OR SMUDGES OF ANY NATURE. 13.REPRESENTATIONS OF TRUE NORTH, OTHER THAN THOSE FOUND ON THE PLOT OF SURVEY DRAWING, SHALL NOT BE USED TO IDENTIFY OR ESTABLISH THE BEARING OF TRUE NORTH AT THE SITE. THE CONTRACTOR SHALL RELY SOLELY ON THE PLAT OF SURVEY DRAWING AND ANY SURVEYOR'S MARKINGS AT THE SITE FOR THE ESTABLISHMENT OF TRUE NORTH, AND SHALL NOTIFY THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH THE WORK. IF ANY DISCREPANCY IS FOUND BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND THE TRUE NORTH ORIENTATION AS DEPICTED ON THE CIVIL SURVEY. THE CONTRACTOR SHALL ASSUME SOLE LIABILITY FOR ANY FAILURE TO NOTIFY THE ARCHITECT/ENGINEER. 14.PENETRATIONS OF ROOF MEMBRANES SHALL BE PATCHED/FLASHED AND MADE WATERTIGHT USING LIKE MATERIALS IN ACCORDANCE WITH NRCA ROOFING STANDARDS AND DETAILS. CONTRACTOR SHALL OBTAIN DETAILING CLARIFICATION FOR SITE-SPECIFIC CONDITIONS FROM ARCHITECT/ENGINEER, IF NECESSARY, BEFORE PROCEEDING. PLANS ARE NOT TO BE SCALED AND ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY, UNLESS NOTED OTHERWISE. 15.ALL ITEMS REMOVED DURING CONSTRUCTION WORK (I.E. DRYWALL, PLYWOOD, CEILING PANELS, ETC.) SHALL BE REPLACED TO MATCH EXISTING. 16.PLANS ARE NOT BE SCALED AND ARE INTENDED TO BE DIAGRAMMATIC OUTLINE ONLY, UNLESS NOTED OTHERWISE. 17.DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALES SHOWN ON THE DRAWING. DIMENSIONS SHOW ARE ESTIMATED AND SHALL BE VERIFIED BY A SURVEYOR OR BY THE CONTRACTOR PRIOR TO CONSTRUCTION. 18.ALL SITE WORK SHALL BE CAREFULLY COORDINATED BY GENERAL CONTRACTOR WITH LOCAL UTILITY COMPANY, TELEPHONE COMPANY, AND ANY OTHER UTILITY COMPANIES HAVING JURISDICTION OVER THIS LOCATION. 19.CONTRACTOR IS ADVISED TO READ ALL NOTES ON DRAWINGS, CAREFULLY. 20.CONTRACTOR TO FIELD VERIFY LOCATIONS OF ALL OVERHEAD OBSTRUCTIONS PRIOR TO COMMENCEMENT OF WORK. 21.THE CONTRACTOR SHALL CONTACT MASSACHUSETTS 811 AT 888-344-7233 TO REQUEST LOCATING AND MARKING OF EXISTING UTILITIES PRIOR TO PERFORMING ANY EXCAVATION WORK IN OR AROUND ANY UTILITY. THE CONTRACTOR SHALL OBTAIN ALL PERMITS FOR THE INSTALLATION OF THE NEW UTILITIES AND SHALL COMPLY WITH ALL REQUIREMENTS OF ALL AGENCIES HAVING JURISDICTION OVER THE WORK. 22.ALL DISCREPANCIES SHOULD BE REPORTED TO HBK ENGINEERING, LLC AT 312-432-0076. ANY QUESTIONS OR COMMENTS THE CONTRACTOR MAY HAVE ARE TO BE DISCUSSED WITH THE OWNER AND ENGINEER PRIOR TO CONSTRUCTION COMMENTS. 23.FURTHER, THE CONTRACTOR SHALL RECORD THE LOCATION AND ELEVATION OF ALL UTILITIES ENCOUNTERED, AND INSTALLATION OF NEW WORK, AS THE WORK PROGRESSES AND SHALL PREPARE RECORD DRAWINGS (RED-LINES) BASED ON HIS RECORDS. THESE RECORDS TO BE SUPPLIED TO HBK ENGINEERING, LLC AT COMPLETION OF WORK. 24.SCALE FOR DRAWINGS IS FOR GENERAL INFORMATION ONLY. LOCATIONS AND DIMENSIONS SHALL BE TAKEN AS SHOWN AND THE DRAWINGS SHALL NOT BE SCALED. 25.THE CONTRACTOR SHALL HAVE ALL PERMITS ONSITE AND COMPLY WITH THE REQUIREMENTS OF ALL AGENCIES HAVING JURISDICTION OVER THE WORK AND SHALL COORDINATE HIS WORK WITH THE WORK PERFORMED BY OTHERS. 26.CONTRACTOR SHALL COORDINATE ALL WORK WITH ALL PUBLIC AND PRIVATE UTILITIES AS WELL AS CITY AND STATE AGENCIES. 27.CONTRACTOR SHALL TAKE ALL NECESSARY SAFETY PRECAUTIONS TO PROTECT UTILITIES, PEDESTRIANS, WORKERS AND VEHICULAR TRAFFIC. THE CONTRACTOR SHALL PROVIDE TEMPORARY FENCES, BARRICADES, ETC. AS REQUIRED TO PROTECT ADJACENT PROPERTY AND THE PUBLIC DURING ALL PHASES OF CONSTRUCTION. 28.THE CONTRACTOR SHALL INSTALL AND DESIGN WOODEN PASSAGEWAYS TO DIVERT THE GENERAL PUBLIC AROUND THE CONSTRUCTION SITE IN A SAFE AND ORDERLY MANNER, AS REQUIRED. 29.NO STORAGE OF EQUIPMENT OR MATERIALS IN THE ROADWAY IS PERMITTED UNLESS THE CONTRACTOR OBTAINS WRITTEN PERMISSION FROM THE CITY, STATE, AND/OR GOVERNING BODY. 31.CONTRACTOR SHALL ASSUME ALL CABLES ARE ENERGIZED AND SHALL BE SUPPORTED SO AS NOT TO STRESS ANY PORTION OF THE CABLE. 32.CONTRACTOR RESPONSIBLE FOR OBTAINING AND PROVIDING REVIEW AND DESIGN OF ANY AND ALL TEMPORARY UTILITY SUPPORT SYSTEMS PRIOR TO CONSTRUCTION. 33.SEE REQUIRED MINIMUM CABLE MIDSPAN HEIGHTS ON DETAILS SHEET. 34.CONTRACTOR TO TREE TRIM AS NECESSARY AROUND POLES. 35.MAKE READY INDICATES EXISTING FIBER CABLES NEED ADJUSTMENTS IN ORDER FOR NEW FIBER CABLE TO MEET REQUIRED CODES OR CLEARANCES. 36.CONTRACTOR ONLY TO INSTALL IN AREAS WITH RIGHT OF ENTRY/PERMITTING COORDINATED BY GATEWAY (EASEMENTS, PRIVATE PROPERTY, AND RIGHT OF WAY AS APPLICABLE). 37.ALL BURIED CABLE 100' OR GREATER IN LENGTH SHOULD BE GROUNDED AT THE BEGINNING, END AND SPACED NO MORE THAN 2,500' APART ALONG THE CABLE. ALL END OF RUN PEDESTALS AND 3-WAY SPLICE LOCATIONS SHALL BE GROUNDED. THESE LOCATIONS SHOULD HAVE A GROUND ROD, ALL FIBER PEDESTALS WITH A GROUND ROD NEED A #6 BARE GROUND WIRE FROM THE GROUND ROD TO THE GROUND BAR IN THE PEDESTAL. ALL FIBER PEDESTALS NEED THE FIBER TRACER WIRES BONDED TO THE GROUND BAR IN THE PEDESTAL. 38.WHEN FIELD CONDITIONS PREVENT THE PLACEMENT OF A GROUND SOURCE AT THE BEGINNING OR END OF THE CABLE SECTION, THE CABLE SHOULD BE GROUNDED AS CLOSE AS POSSIBLE TO THE BEGINNING OR END NOT TO EXCEED 500' FROM THE PLANNED LOCATION. 39.THE CONTRACTOR SHALL FIELD ADJUST INTERMEDIATE GROUND LOCATIONS AS LONG AS THE MAXIMUM SPACING IS MAINTAINED. THE CONTRACTOR SHALL EXERCISE FLEXIBILITY WHEN SELECTING A NEW GROUND LOCATION ALONG THE CABLE ROUTE TO AVOID CONCRETE, ASPHALT ETC AND CHOOSE THE MOST ECONOMICAL LOCATION. 40.FOR AERIAL CABLE THE STRAND MUST BE GROUNDED AT THE BEGINNING, END AND AT LEAST ONCE EVERY ¼ MILE (1,320FT). THE CABLE MUST BE BONDED TO THE STRAND AT ALL SPLICE LOCATIONS AND AT LEAST ONCE EVERY ¼ MILE. FOR ATTACHMENTS NEAR HIGH VOLTAGE LINES OVER 15KV INCREASE GROUNDING FREQUENCY TO EVERY 1/8 MILE. (660'). FOR ATTACHMENT TO POLES CONTAINING OVER 34KV CABLES THE CONTRACTOR SHALL GROUND AT EVERY POLE. 41.THE CONTRACTOR SHALL FIELD ADJUST AERIAL GROUNDING TO ADJACENT POLES AT THEIR OPTION AS LONG AS THE MAXIMUM ¼ MILE IS MAINTAINED. 42.OUTDOOR CABINETS SHALL BE GROUNDED PER THE MANUFACTURER'S RECOMMENDATIONS AND PER ANSI/TIA-607B OR LATEST STANDARD. 43.MARKER POST LOCATIONS SHALL BE DETERMINED IN THE FIELD. MARKER POSTS SHALL BE PLACED AT STRATEGIC LOCATIONS THROUGHOUT THE PROJECT INCLUDING AT PREFERRED LOCATIONS AT BACKBONE SPLICES, MAJOR ROAD CROSSINGS AND AT THE DIRECTION OF GATEWAY. PROPOSED 4-4" BURIED CONDUIT INSTALLATION, TO TURN 90 DEGREES AND TRAVEL UP WALL TO LOWER ENTRY PORTS. SEE DETAIL B. PROPOSED HANDHOLE LOCATION PROPOSED 1-4" ELECTRICAL CONDUIT. SEE DETAIL B. 48"X48" HH PROPOSED COMMUNICATION HUT LOCATION ON CONCRETE PAD 1.0' APPROXIMATE EXTENT OF PROPOSED 20'x20' EASEMENT DETAIL A TOP VIEW OF EASEMENT SCALE 1" = 4' 4'X5' CONCRETE PAD 1-4" TEMPORARY AERIAL POWER DROP CONDUIT PROPOSED 2-4" TEMPORARY BURIED FIBER DROP CONDUITS, TO TURN 90 DEGREES AND TRAVEL UP WALL TO WEATHERHEAD. SEE DETAIL B. 17"X30" HH METER GEN PROJECT NOTES 1.GENERATOR, METER, AND HVAC DIMENSIONS AND PLACEMENT NOT SHOWN TO SCALE. SEE CELLSITE AND ROHN DRAWINGS FOR DIMENSIONING AND STRUCTURE DETAILS. SET BACK 10.0' 12.0' 4.0' 5.0' 20.0' 20.0' 11.0' 1.0' 3.0' 4.0' 1.0'HVACAPPROXIMATE LOCATION. SEE NOTE 1. APPROVED BY: SHEET: DATE DRAWN: PROJECT NUMBER: DRAWN BY:CHECKED BY: DESCRIPTION REVISIONS 04 07 05 06 08 09 10 11 DATE 00 01 03 02 REV BY TITLE: ENGINEER: FIBERHOOD: 921 WEST VAN BUREN, SUITE 100 CHICAGO, IL 60607 PHONE: (312) 432-0076 FAX:(312) 432-0231 STATE OF ILLINOIS, DEPARTMENT OF PROFESSIONAL REGULATION. LICENSE NO. 184-002308 B1 AJR NJF AJR 24-0404 10/30/2024 SHELTER LOCATION 10/30/2024 FOR CONSTRUCTION AJR PROPOSED FIBER - OPTIC INSTALLATION - CIVIL DESIGN 187 LOCUST ST NORTHAMPTON, MA N 275 WEST SERVICE RD SUITE O WRIGHT CITY, MO 63390 OWNER/DEVELOPER: DETAILS DETAIL B NORTH WALL SIDE VIEW OF CONDUITS & METER SCALE 1" = 4' EXISTING 2" DIA ATS HOLE WALL ENTRY (DO NOT DRILL OR PLUG EXISTING HOLE) 1 2" SCH 40 PVC CAST @ 40" (TYP.) 12 ENTRY PORT PANEL PROPOSED 4-4" CONDUIT INSTALLATION, TO TURN 90 DEGREES AND TERMINATE AT 48"X48" HAND HOLE. SEE DETAIL A. 2-4" TEMPORARY FIBER DROP CONDUIT LEADING TO HH. SEE DETAIL A. HVAC. SEE NOTE 1. PROJECT NOTES 1.GENERATOR, METER, AND HVAC DIMENSIONS AND PLACEMENT NOT SHOWN TO SCALE. SEE CELLSITE AND ROHN DRAWINGS FOR DIMENSIONING AND STRUCTURE DETAILS. 2.SEE CELLSITE AND ROHN DRAWINGS FOR DIMENSIONING AND STRUCTURE DETAILS. 3.CONTRACTOR TO INSTALL AERIAL DROP CONDUITS PER NESC CLEARANCE WITH WEATHERHEADS. 2-4" TEMPORARY FIBER DROP CONDUIT LEADING TO HH. TO TURN 90 DEGREES AND TERMINATE AT 48"X48" HAND HOLE. 1-4" TEMP AERIAL POWER DROP CONDUIT APPROXIMATE LOCATION OF ELECTRIC METER. SEE NOTE 1. PROPOSED 1-4" ELECTRICAL CONDUIT. SEE DETAIL A. APPROVED BY: SHEET: DATE DRAWN: PROJECT NUMBER: DRAWN BY:CHECKED BY: DESCRIPTION REVISIONS 04 07 05 06 08 09 10 11 DATE 00 01 03 02 REV BY TITLE: ENGINEER: FIBERHOOD: 921 WEST VAN BUREN, SUITE 100 CHICAGO, IL 60607 PHONE: (312) 432-0076 FAX:(312) 432-0231 STATE OF ILLINOIS, DEPARTMENT OF PROFESSIONAL REGULATION. LICENSE NO. 184-002308 B2 AJR NJF AJR 24-0404 10/30/2024 SHELTER LOCATION 10/30/2024 FOR CONSTRUCTION AJR PROPOSED FIBER - OPTIC INSTALLATION - CIVIL DESIGN 187 LOCUST ST NORTHAMPTON, MA 275 WEST SERVICE RD SUITE O WRIGHT CITY, MO 63390 OWNER/DEVELOPER: DETAILS APPROVED BY: SHEET: DATE DRAWN: PROJECT NUMBER: DRAWN BY:CHECKED BY: DESCRIPTION REVISIONS 04 07 05 06 08 09 10 11 DATE 00 01 03 02 REV BY TITLE: ENGINEER: FIBERHOOD: 921 WEST VAN BUREN, SUITE 100 CHICAGO, IL 60607 PHONE: (312) 432-0076 FAX:(312) 432-0231 STATE OF ILLINOIS, DEPARTMENT OF PROFESSIONAL REGULATION. LICENSE NO. 184-002308 C1 AJR NJF AJR 24-0404 10/30/2024 SHELTER LOCATION 10/30/2024 FOR CONSTRUCTION AJR PROPOSED FIBER - OPTIC INSTALLATION - CIVIL DESIGN 187 LOCUST ST NORTHAMPTON, MA 275 WEST SERVICE RD SUITE O WRIGHT CITY, MO 63390 OWNER/DEVELOPER: DETAILS