Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
18 Lonsdale Ave Macdonald_Signed building and electric Permit App with submittals
Catherine Macdonald-Amias 18 Lonsdale Ave Apt 2 Florence MA 01062 413-320-8390 catmacd@gmail.com 00640850 9/23/2024 Northeast Solar Design Associates - David J Baird 136 Elm St Hatfield Ma 01038 413-247-6045 413-674-0006 Interconnection@northeast-solar.com 21918A N/ASMART ID#: Contruction WR#:N/A 18 Lonsdale Ave Apt 2 Florence MA 01062 INSR ADDLSUBRLTRINSR WVD DATE (MM/DD/YYYY) PRODUCER CONTACTNAME: FAXPHONE(A/C, No):(A/C, No, Ext): E-MAILADDRESS: INSURER A : INSURED INSURER B : INSURER C : INSURER D : INSURER E : INSURER F : POLICY NUMBER POLICY EFF POLICY EXPTYPE OF INSURANCE LIMITS(MM/DD/YYYY) (MM/DD/YYYY) COMMERCIAL GENERAL LIABILITY AUTOMOBILE LIABILITY UMBRELLA LIAB EXCESS LIAB WORKERS COMPENSATION AND EMPLOYERS' LIABILITY DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) AUTHORIZED REPRESENTATIVE INSURER(S) AFFORDING COVERAGE NAIC # Y / N N / A (Mandatory in NH) ANY PROPRIETOR/PARTNER/EXECUTIVEOFFICER/MEMBER EXCLUDED? EACH OCCURRENCE $ DAMAGE TO RENTED $PREMISES (Ea occurrence)CLAIMS-MADE OCCUR MED EXP (Any one person) $ PERSONAL & ADV INJURY $ GENERAL AGGREGATE $ GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS - COMP/OP AGG $ $ PRO- OTHER: LOCJECT COMBINED SINGLE LIMIT $(Ea accident) BODILY INJURY (Per person) $ANY AUTO OWNED SCHEDULED BODILY INJURY (Per accident) $AUTOS ONLY AUTOS AUTOS ONLYHIRED PROPERTY DAMAGE $AUTOS ONLY (Per accident) $ OCCUR EACH OCCURRENCE $ CLAIMS-MADE AGGREGATE $ DED RETENTION $ $ PER OTH-STATUTE ER E.L. EACH ACCIDENT $ E.L. DISEASE - EA EMPLOYEE $ If yes, describe under E.L. DISEASE - POLICY LIMIT $DESCRIPTION OF OPERATIONS below POLICY NON-OWNED SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer any rights to the certificate holder in lieu of such endorsement(s). COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: CERTIFICATE HOLDER CANCELLATION © 1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORDACORD 25 (2016/03) ACORDTM CERTIFICATE OF LIABILITY INSURANCE Gotham Insurance Company National Casualty Company Safety First Insurance Company 7/19/2024 Edgewood Partners Ins. Center 144 Gould Street, Suite 100 Needham, MA 02494 781 455-0700 Commercial Support 631 390-9700 NECertificates@epicbrokers.com Northeast Solar Design Associates, LLC 136 Elm Street Hatfield, MA 01038 25569 11991 11123 AX X X BI/PD Ded:5,000 X PK2023000276 07/22/2024 07/08/2025 1,000,000 500,000 5,000 1,000,000 2,000,000 2,000,000 C X XX 5909629 07/08/2024 07/08/2025 1,000,000 A XX X 10000 EX2023000037 07/22/2024 07/08/2025 1,000,000 1,000,000 B N WCC334761A 07/08/2024 07/08/2025 X 1,000,000 1,000,000 1,000,000 Issued as Evidence of Insurance. City of Northampton 210 North Main Street Northampton, MA 01060 1 of 1#S6783585/M6783572 NORTSOLClient#: 169764 NVE02 Vreeland Design Associates An integrative approach to design engineering and site planning 116 River Road, Leyden, MA 01337 Phone: (413) 624-0126 Email: dvreeland@verizon.net Fax: (413) 624-3282 Date October 14, 2024 To: Justin Annis NorthEast Solar 136 Elm Street Hatfield, MA 01038 From: David Vreeland, P.E. Vreeland Design Associates Re: Cat MacDonald-Amias, 18 Lonsdale Avenue, Florence, MA: Structural assessment of existing house roof to support proposed PV solar panel array. I have investigated the existing house roof framing for the proposed PV solar panel installation. Based on the assessor’s records the original 28’x 34’, 2-story house was constructed around 1900. A 12’x 24’, 2-story addition off the northeast gable end appears to have been constructed at a later date. 14 PV solar panels are to be installed on the southeast facing roof of the house. The house roof is framed with 2”x 6” rafters installed 24” on-center, spanning 13’-6” with a 7/12 pitch. A 2x4 kneewall, located approximately 8’ in from the exterior wall, appears to be supported on 2”x 8” attic joists which are secured to the top of the wall preventing the roof from spreading. The roofing is composite asphalt shingles which appears to be secured to plywood sheathing laid over the original 1” roof boards. I have reviewed the mounting details for the PV solar panel array. Based on my calculations and a PV solar panel unit weight of 52± lbs, with the attachment points of the array placed at a maximum of 4’ on-center and staggered to minimize the load to any one rafter, the existing house roof framing is adequate to support the proposed PV solar panel array and the 40 psf ground and 35 psf roof snow loads and the 117 mph Vult basic wind speed requirements of the current 9th Edition of the MA State Building Code for the City of Northampton. Please contact me if you have any questions or need additional information. Sincerely, David Vreeland, PE Vreeland Design Associates wp470 21.0 w sq-ft α EXPERIENCE PERFORMANCE ELIGIBLE LEAD-FREE ROHS COMPLIANT Efficiency22.6% COMPACT PANEL Size 9 A module Current compatible with MLPE rec Alpha® Pure-RX Series Product Specifications REC Solar PTE. LTD. 20 Tuas South Ave. 14 Singapore 637312 post@recgroup.com www.recgroup.com Founded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar’s Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia-Pacific. REC Alpha Pure-RX Series Product SPECIFICATIONS Available from: GENERAL DATA Cell type:88 half-cut bifacial REC heterojunction cells with lead-free, gapless technology Glass:0.12 in solar glass with anti-reflective surface treatment in accordance with EN 12150 Backsheet:Highly resistant polymer Frame:Anodized aluminum (black) Junction box:4-part, 4 bypass diodes, lead-free IP68 rated, in accordance with IEC 62790 Connectors:Stäubli MC4 PV-KBT4/KST4 (12 AWG) in accordance with IEC 62852, IP68 only when connected Cable:12 AWG solar cable, 66.9 + 66.9 in in accordance with EN 50618 Dimensions:68.0 x 48.1 x 1.2 in (22.4 sq-ft) Weight:51.6 lbs Origin:Made in Singapore Measurements in inches 85 90 95 100 105 200100 300 400 500 600 700 800 900 1000 LOW LIGHT BEHAVIOUR STC NMOTCERTIFICATIONS IEC 61215:2021, IEC 61730:2016, UL 61730 IEC 62804 PID IEC 61701 Salt Mist IEC 62716 Ammonia Resistance ISO 11925-2 Ignitability (EN 13501-1 Class E) IEC 62782 Dynamic Mechanical Load IEC 61215-2:2016 Hailstone (35mm) IEC 62321 Lead-free acc. to RoHS EU 863/2015 UL 61730 Fire Type 2 ISO 14001, ISO 9001, IEC 45001, IEC 62941 Lead-Free WARRANTY Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All ≤25 kW 25-500 kW Product Warranty (yrs)20 25 25 Power Warranty (yrs)25 25 25 Labor Warranty (yrs)0 25 10 Power in Year 1 98%98%98% Annual Degradation 0.25%0.25%0.25% Power in Year 25 92%92%92% The REC ProTrust Warranty is only available on panels purchased through an REC Certified Solar Professional installer. Warranty conditions apply. See www.recgroup.com for more details. DELIVERY INFORMATION Panels per pallet:33 Panels per 40 ft GP/high cube container:594 (18 pallets) Panels per 53 ft truck:792 (24 pallets) ELECTRICAL DATA Product Code*: RECxxxAA Pure-RX Power Output - PMAX (Wp) 450 460 470 Watt Class Sorting - (W)0/+10 0/+10 0/+10 Nominal Power Voltage - VMPP (V) 54.3 54.9 55.4 Nominal Power Current - IMPP (A) 8.29 8.38 8.49 Open Circuit Voltage - VOC (V) 65.1 65.3 65.6 Short Circuit Current - ISC (A) 8.81 8.88 8.95 Power Density (W/sq-ft)20.1 20.5 21.0 Panel Efficiency (%) 21.6 22.1 22.6 Power Output - PMAX (Wp)343 350 358 Nominal Power Voltage - VMPP (V) 51.2 51.7 52.2 Nominal Power Current - IMPP (A) 6.70 6.77 6.86 Open Circuit Voltage - VOC (V) 61.3 61.6 61.8 Short Circuit Current - ISC (A) 7.11 7.17 7.23 Values at standard test conditions (STC: air mass AM 1.5, irradiance 1000 W/m², temperature 77°F (25°C)), based on a production spread with a tolerance of PMAX, VOC & ISC ±3% within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², temperature 68°F (20°C), windspeed 3.3 ft/s (1 m/s)). * Where xxx indicates the nominal power class (PMAX) at STC above. GRGRGR GR GR11±0.26.6±0.220.5±0.5 6.0±0.217001700 GR GR GR GR GR0.43±0.01 0.26±0.010.8±0.02 0.24±0.01 66.9 66.9 68.0 ±0.1 32.2 17.9 46.1 ±0.10.9 23.4 ±0.12 48.1 ±0.10.71.8 1.21728±2.5 818 455 1171 ±2.5 22.5 594 ±31205 ±2.517 45 30Living Building Challenge Compliant MAXIMUM RATINGS Operational temperature:-40 ... +185°F System voltage:1000 V Test load (front):+7000 Pa (146.2 lbs/sq-ft)* Test load (rear):-4000 Pa (83.5 lbs/sq-ft)* Series fuse rating:25 A Reverse current:25 A * See installation manual for mounting instructions. Design load = Test load / 1.5 (safety factor) TEMPERATURE RATINGS * Nominal Module Operating Temperature:44°C (±2°C) Temperature coefficient of PMAX:-0.24 %/°K Temperature coefficient of VOC:-0.24 %/°K Temperature coefficient of ISC:0.04 %/°K *The temperature coefficients stated are linear values Irradiance (W/m²)Rel. Efficiency (%)Typical low irradiance performance of module at STC:Ref: PM-DS-AAPRX-Rev- 3.1 10.23Specifications subject to change without notice. DATA SHEET IQ8X Microinverter Our newest IQ8 Series Microinverters are the industry’s first microgrid-forming*, software-defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application- specific integrated circuit (ASIC), which enables the microinverter to operate in grid-tied or off-grid mode. This chip is built using advanced 55-nm technology with high-speed digital logic and superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. IQ8X Microinverter is the latest addition to this family, designed to support PV modules with high output DC voltage and cell counts, such as 80-half-cut cells, 88-half-cut cells and 96-cells. *Meets UL 1741 only when installed with IQ System Controller 2 or 3. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the IQ Battery, IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. IQ8 Series Microinverters are UL Listed as PV rapid shutdown equipment and conform with regulations when installed according to the manufacturer’s instructions. Connect PV modules quickly and easily to the IQ8 Series Microinverters with integrated MC4 connectors. Easy to install • Lightweight and compact with plug- and-play connectors • Power line communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produces power even when the grid is down* • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high-powered PV modules Microgrid-forming • Complies with the latest advanced grid support • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB) NOTE: • IQ8 Series Microinverters cannot be mixed with previous generations of Enphase microinverters (IQ7 Series, IQ6 Series, and so on) in the same system. • IQ Microinverters ship with default settings that meet North America’s IEEE 1547 interconnection standard requirements. Region-specific adjustments may be requested by an Authority Having Jurisdiction (AHJ) or utility representative, according to the IEEE 1547 interconnection standard. An IQ Gateway is required to make these changes during installation. IQ8X-MC4-DSH-00185-3.0-EN-US-2024-02-12 © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. (1) No enforced DC/AC ratio. (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. (4) IQ8X is not certified for use with Enphase Three Phase Network Protection Relay (NPR-3P-208-NA) and is, therefore, designed for single-phase operation only. Check with the local utility requirements if you wish to install single-phase inverters across three phases. IQ8X Microinverter INPUT DATA (DC)UNIT IQ8X-80-M-US Commonly used module pairings 1 W 320–540 Module compatibility —To meet compatibility, PV modules must be within the following maximum input DC voltage and maximum module Isc Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator MPPT voltage range V 43–60 Operating range V 25–79.5 Minimum and maximum start voltage V 30–79.5 Maximum input DC voltage V 79.5 Maximum continuous operating DC current A 10 Maximum input DC short-circuit current A 16 Maximum module Isc A 13 Overvoltage class DC port —II DC port backfeed current mA 0 PV array configuration —Ungrounded array; no additional DC side protection required; AC side protection requires a maximum of 20 A per branch circuit OUTPUT DATA (AC)UNIT IQ8X-80-M-US @240 VAC IQ8X-80-M-US @208 VAC Peak output power VA 384 366 Maximum continuous output power VA 380 360 Nominal grid voltage (L-L)V 240, split-phase (L-L), 180°208, single-phase (L-L), 120° 4 Minimum and maximum grid voltage 2 V 211–264 183–229 Max. continuous output current A 1.58 1.73 Nominal frequency Hz 60 Extended frequency range Hz 47–68 AC short circuit fault current over three cycles Arms 2.70 Maximum units per 20 A (L-L) branch circuit 3 —10 9 Total harmonic distortion %<5 Overvoltage class AC port —III AC port backfeed current mA 18 Power factor setting —1.0 Grid-tied power factor (adjustable)—0.85 leading … 0.85 lagging Peak efficiency %97.3 97.0 CEC weighted efficiency %96.5 96.5 Nighttime power consumption mW 26 12 MECHANICAL DATA Ambient temperature range -40°C to 65°C (-40°F to 149°F) Relative humidity range 4% to 100% (condensing) DC connector type Stäubli MC4 Dimensions (H × W × D); Weight 212 mm (8.3") × 175 mm (6.9") × 30.2 mm (1.2"); 1.1 kg (2.43 lb) Cooling Natural convection – no fans Approved for wet locations; Pollution degree Yes; PD3 Enclosure Class II double-insulated, corrosion-resistant polymeric enclosure Environmental category; UV exposure rating NEMA Type 6; outdoor COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, IEEE 1547:2018 (UL 1741-SB), FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01. This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014, NEC 2017, NEC 2020, and NEC 2023 section 690.12 and C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer’s instructions. IQ8X-MC4-DSH-00185-3.0-EN-US-2024-02-12 Tech Brief The Strongest Attachment in Solar IronRidge® FlashFoot2® raises the bar in solar roof protection. The unique water seal design is both elevated and encapsulated, delivering redundant layers of protection against water intrusion. In addition, the twist-on Cap perfectly aligns the rail attachment with the lag bolt to maximize mechanical strength. FlashFoot2® Twist-On Cap FlashFoot2®’s unique Cap design encapsulates the lag bolt and locks into place with a simple twist. The Cap helps FlashFoot2® deliver superior structural strength, by aligning the rail and lag bolt in a concentric load path. Single Socket Size A custom-design lag bolt allows you to install FlashFoot2® with the same 7/16” socket size used on other Flush Mount Three-Tier Water Seal FlashFoot2®’s seal architecture utilizes three layers of protection. An elevated platform diverts water away, while a stack of rugged components raises the seal an entire inch. The seal is then fully-encapuslated by the Cap. FlashFoot2® is the first solar attachment to pass the TAS-100 Wind-Driven Water-Shedding Design An elevated platform diverts water away from the water seal. © 2022 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.01 Tech Brief Installation Features Testing & Certification Structural Certification Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7. Water Seal Ratings Water Sealing Tested to UL 441 Section 27 “Rain Test” and TAS 100-95 “Wind Driven Rain Test” by Intertek. Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. UL 2703 Conforms to UL 2703 Mechanical and Bonding Requirements. See Flush Mount Install Manual for full ratings. Alignment Markers Quickly align the flashing with chalk lines to find pilot holes. Rounded Corners Makes it easier to handle and insert under the roof shingles. Reinforcement Ribs Help to stiffen the flashing and prevent any bending or crinkling during installation. A B C E B C Benefits of Concentric Loading Traditional solar attachments have a horizontal offset between the rail and lag bolt, which introduces leverage on the lag bolt and decreases uplift capacity. FlashFoot2® is the only product to align the rail and lag bolt. This concentric loading design results in a stronger attachment for the system. A ® ® Tech Brief Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. XR Rail Family Force-Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat & Pitched Roofs Roof Mount utilizes XR Rails, along with optional all-in-one attachments, to secure systems flush against residential roofs. Corrosion-Resistant Materials XR Rails are compatible with FlashFoot and other pitched roof attachments. IronRidge offers a range of tilt leg options for flat roof mounting applications. All XR Rails are made of 6000-series aluminum alloy, then protected with an anodized finish. Anodizing prevents surface and structural corrosion, while also providing a more attractive appearance. XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. © 2020 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.20 Tech Brief Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria: ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. Load Rail Span Snow (PSF)Wind (MPH)4’5’ 4”6’8’10’12’ None 90 120 140 XR10 XR100 XR1000 160 20 90 120 140 160 30 90 160 40 90 160 80 160 120 160 XR100 XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 10 feet. • 10’ spanning capability • Heavy load capability • Clear & black anodized finish • Internal splices available XR10 XR10 is a sleek, low-profile mounting rail, designed for regions with light or no snow. It achieves spans up to 6 feet, while remaining light and economical. • 6’ spanning capability • Moderate load capability • Clear & black anodized finish • Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It’s built to handle extreme climates and spans up to 12 feet for commercial applications. • 12’ spanning capability • Extreme load capability • Clear anodized finish • Internal splices available *Table is meant to be a simplified span chart for conveying general rail capabilities. Use approved certification letters for actual design guidance.