Levitt, Sam plans SS
CONFIDENTIAL
THE INFORMATION HEREIN CONTAINED SHALL NOT
BE DISCLOSED TO OTHERS OUTSIDE OF CURRENT
ENERGY LLC, WITHOUT CONSENT OR IN
CONNECTION WITH THE SALE AND USE OF THE
RESPECTIVE CURRENT ENERGY LLC SYSTEM
Current Energy LLC
305 Wells St. Greenfield, MA 01301
www.currentenergy.pro 413-658-2047
CLIENT Levitt, Sam PROJECT 379 SYSTEM SIZE DC 9.4 UTILITY National Grid DATE REV:BY:
ADDRESS 69 Lyman Rd MOUNTING SunModo SYSTEM SIZE AC 7.6 SHEET NUMBER 4/29/2024 1 CTKREZMIEN
Northampton, MA 01060 MODULES Q.Cell 410G10 ENERGY STORAGE SYSTEM N/A SHEET SIZE 11" X 17"6/7/2024 2 CTKREZMIEN
PHONE 413-530-8868 INVERTER SE HOME EV CHARGER N/A SHEET TITLE PROPERTY PLAN
PROPERTY LINES
SETBACKS
LEGEND N
S
EW
1
L
Y
M
A
N
R
D
Utility Meter
PV Disconnect
SE7600H-US
INVERTER
9.4 kW
Solar Array
Main Service Panel
Vector Structural Engineering has reviewed the existing
structure with loading from the solar array and screw
connections to the existing framing. The design of the
racking system, racking connections, and all other
structural is by others. Mechanical, architectural, and all
other nonstructural aspects of the design are by others.
Electrical is by others, unless stamped by Dean Levorsen.
06/11/2024
VSE Project Number: U6045.0020.241
651 W. galena park blvd. ste. 101
draper, Utah 84020
phone (801) 990-1775
www.vectorse.com
®
1691 2
1691 2
130
18
38MP3
MP4
MP1
MP2
3127 8
36 241 36
169
367 8
1151 8
18
74
18
78
74
12
4913 16
12
6
291 2
6
12
4913 16
12
12
4913 16
12
48
24
RED LINES REPRESENT NFP SETBACKS
367 8
1151 8
18
417 16 2901 8
365 1612418
3612418
N
S
EW
HOUSE ARRAY LAYOUT
CONFIDENTIAL
THE INFORMATION HEREIN CONTAINED SHALL NOT
BE DISCLOSED TO OTHERS OUTSIDE OF CURRENT
ENERGY LLC, WITHOUT CONSENT OR IN
CONNECTION WITH THE SALE AND USE OF THE
RESPECTIVE CURRENT ENERGY LLC SYSTEM
Current Energy LLC
305 Wells St. Greenfield, MA 01301
www.currentenergy.pro 413-658-2047
CLIENT Levitt, Sam PROJECT 379 SYSTEM SIZE DC 9.4 UTILITY National Grid DATE REV:BY:
ADDRESS 69 Lyman Rd MOUNTING SunModo SYSTEM SIZE AC 7.6 SHEET NUMBER 4/29/2024 1 CTKREZMIEN
Northampton, MA 01060 MODULES Q.Cell 410G10 ENERGY STORAGE SYSTEM N/A SHEET SIZE 11" X 17"6/7/2024 2 CTKREZMIEN
PHONE 413-530-8868 INVERTER SE HOME EV CHARGER N/A SHEET TITLE CONSTRUCTION PLAN
INVERTER IN BASEMENT
3
PROJECT NOTES
ROOF/GROUND DETAILS
TYPE Composite Shingle
SLOPE 27°
# ROOF(S)2
ADDITIONAL WORK
SNOW GUARD N
SERVICE UPGRADE N
EV CHARGER N
ENERGY STORAGE N
EQUIPMENT LOCATION
MODULES MP1 - 4
INVERTER BASEMENT
AC DISCONNECT BESIDE UTILITY METER
AC COMBINER N/A
COMMS ROUTER TO INVERTER
MOUNTING DETAILS
MAX CANTILEVER 12"
SPAN 4' STAGGERED
RAIL IronRidge AIRE
ATTACHMENT HALO ULTRAGRIP
MOUNT SPACING 4'
COMPONENTS
Q.Peak 410 23
HUG 70
AIRE A2 173"16
ROOF BOX 3
MID CLAMPS 30
END CLAMPS 32
VSE Project Number: U6045.0020.241
651 W. galena park blvd. ste. 101
draper, Utah 84020
phone (801) 990-1775
www.vectorse.com
®
1691 2"
36116"
18"
1157 16"
27°
143"
18"
6"
6"
12"
12"
36116"
HOUSE FRAMING
ROOF FRAMING HOUSE
STRUCTURAL
CONFIDENTIAL
THE INFORMATION HEREIN CONTAINED SHALL NOT
BE DISCLOSED TO OTHERS OUTSIDE OF CURRENT
ENERGY LLC, WITHOUT CONSENT OR IN
CONNECTION WITH THE SALE AND USE OF THE
RESPECTIVE CURRENT ENERGY LLC SYSTEM
Current Energy LLC
305 Wells St. Greenfield, MA 01301
www.currentenergy.pro 413-658-2047
CLIENT Levitt, Sam PROJECT 379 SYSTEM SIZE DC 9.4 UTILITY National Grid DATE REV:BY:
ADDRESS 69 Lyman Rd MOUNTING SunModo SYSTEM SIZE AC 7.6 SHEET NUMBER 4/29/2024 1 CTKREZMIEN
Northampton, MA 01060 MODULES Q.Cell 410G10 ENERGY STORAGE SYSTEM N/A SHEET SIZE 11" X 17"6/7/2024 2 CTKREZMIEN
PHONE 413-530-8868 INVERTER SE HOME EV CHARGER N/A SHEET TITLE
IRONRIDGE
RAFTER ATTACHED
HALO ULTRA
GRIM (HUG)
IRONRIDGE
AIRE RAIL A2
QCell Q.PEAK DUO BLK G10 ML+ 410
FULL DIMENSION
2"X6" 24" OC
MP2 MP1
VSE Project Number: U6045.0020.241
651 W. galena park blvd. ste. 101
draper, Utah 84020
phone (801) 990-1775
www.vectorse.com
®
130"
38"
74"
12"
18"
12"
27°
≈1073 4
CONFIDENTIAL
THE INFORMATION HEREIN CONTAINED SHALL NOT
BE DISCLOSED TO OTHERS OUTSIDE OF CURRENT
ENERGY LLC, WITHOUT CONSENT OR IN
CONNECTION WITH THE SALE AND USE OF THE
RESPECTIVE CURRENT ENERGY LLC SYSTEM
Current Energy LLC
305 Wells St. Greenfield, MA 01301
www.currentenergy.pro 413-658-2047
CLIENT Levitt, Sam PROJECT 379 SYSTEM SIZE DC 9.4 UTILITY National Grid DATE REV:BY:
ADDRESS 69 Lyman Rd MOUNTING SunModo SYSTEM SIZE AC 7.6 SHEET NUMBER 4/29/2024 1 CTKREZMIEN
Northampton, MA 01060 MODULES Q.Cell 410G10 ENERGY STORAGE SYSTEM N/A SHEET SIZE 11" X 17"6/7/2024 2 CTKREZMIEN
PHONE 413-530-8868 INVERTER SE HOME EV CHARGER N/A SHEET TITLE
HOUSE FRAMING
ROOF FRAMING HOUSE
STRUCTURAL
IRONRIDGE
RAFTER ATTACHED
HALO ULTRA
GRIM (HUG)
IRONRIDGE
AIRE RAIL A2
QCell Q.PEAK DUO BLK G10 ML+ 410
FULL DIMENSION
2"X5" 24" OC
VSE Project Number: U6045.0020.241
651 W. galena park blvd. ste. 101
draper, Utah 84020
phone (801) 990-1775
www.vectorse.com
®
CONFIDENTIAL
THE INFORMATION HEREIN CONTAINED SHALL NOT
BE DISCLOSED TO OTHERS OUTSIDE OF CURRENT
ENERGY LLC, WITHOUT CONSENT OR IN
CONNECTION WITH THE SALE AND USE OF THE
RESPECTIVE CURRENT ENERGY LLC SYSTEM
Current Energy LLC
305 Wells St. Greenfield, MA 01301
www.currentenergy.pro 413-658-2047
CLIENT Levitt, Sam PROJECT 379 SYSTEM SIZE DC 9.4 UTILITY National Grid DATE REV:BY:
ADDRESS 69 Lyman Rd MOUNTING SunModo SYSTEM SIZE AC 7.6 SHEET NUMBER 4/29/2024 1 CTKREZMIEN
Northampton, MA 01060 MODULES Q.Cell 410G10 ENERGY STORAGE SYSTEM N/A SHEET SIZE 11" X 17"6/7/2024 2 CTKREZMIEN
PHONE 413-530-8868 INVERTER SE HOME EV CHARGER N/A SHEET TITLE
GARAGE FRAMING
ROOF FRAMING MP1&2
STRUCTURAL
ROOF FRAMING MP3&4