Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Garfield Ave. _ Foundation_Cross Section (2)
10" POURED CONCRETE YLL Yet/ 20"X10" CONT'D FOOTINGS 6 in 2X10 PT LEDGER BOLTED m K i 9 r-------i 8"POURED I CONCRETE VgALL 5' I K 18"X1oil i GONT'D FOOTING5 I { 2X10 FLOOR I J015T5� I ( 16" OG l C I I Rr I 4" POURED CONCRETE FL OR I (3500 P51 K 6 MIL POLY UNDE SLAB { { 34X30X12 CONCRETE PAD I (, I 3-2X10 FLUSH BEA I I - cl ) r I I 3 1/2" LALLY GOLUMN5 I uP 2X10 FLOOR I( J01STS� ( 16" OG I cv I I I � I I I POG L------—BEAM t 6X6 P05T5 M P05T ANGHOR5 3-2X10 PT BEAM 4 PROVIDE RAISED HEEL 6" FASCIA M 12" VENTED 50FFIT�l. 2-2X6 TOP PLATE5-- 2-2X10 HEADER5- R-21 INSULATION 2X12 BOX SILL VINYL 510ING- R-21 IN5ULATI 10" POURED CONCRETE VgALL --" K 20"X10" CONT'D FOOTINGS 2X6 PT SILL N15EALER !N/ 1/2"X12" ANCHOR BOLTS AT 6OG CONT'D RIDGE VENT 5/6" COX SHEATHING ASPHALT 5HINGLE5 Yet/ SYNTHETIC UNDERLAYMENT OR EQUAL 12 ROOF TRU55E5 24" OC 10 TO BE ENGINEERED BY MANUF. F A wCD z � R- IN5ULAT1 N 12" ICE AND Y'IATER BARRIER , � �-- w Lu fL z 2X6 EXT 5TU05 16" OG A 2X4 INT 5TU05 16" OG { z 3/4" T&G ADVANTECH ° n 1/2" DRYVgAALL INT FIN15H "2X12 FLOOR J015T5 16" OC d 2X10 FLOOR 1015T5 16*" OC _ A LVL BEAM TO BE ENGINEERED A5 REO D 1 3 1/2" LATET— `r'SOLUMN5 DAMPPROOFING 2 5/8" THERMAX INSULATION 30X30X12 GONG. PADS PROVIDE CODE COMPLIANT 4" DRAIN TILE SURROUND K 3/4" STONE :: STONE INSIDE FOOTINGS & BACKFILL KITH GLEAN 1NELL DRAINING 501L 4" POURED CONE FLOOR 6 MIL POLY REaUIRED 3500 P51 UNDER HOUSE SLAB 18"X10" CONT'D FOOTINGS K 2X4 KEYVgAY 1NINDON 50HEDL NUMBER LABEL QTY FLOOR SIZE Yq1DTH HEIGHT R/O EGRESS YN01 14360H 2 1 14360H 16 5/16 " 42 " 115/16"X43" NO2 24360H 1 1 24360H 28 " 42 " 2q"X43" NO3 26400H 1 1 26400H 30 " 4611 31 "X4q" N04 26400H 1 2 26400H 30 " 48 " 31 "X4q" kNO5 2816R5 5 0 2816R5 32 " 1511 33"X1 q" Nob 30500H 7 2 30500H 361, 6011 3111X61" N0? 30560H 5 1 30560H 361, 66 " 3711X61" o N08 601 qFX 1 1 6019FX 71 1/2 " 21 " 72 1 /2"X22" 8" POURED Noq 601 qFX 1 2 601 qFX 71 1/2 " 21 " 72 1 /2"X22" N10 2436DH 1 2 24360H 28 " 4211 2q"X43" CONCRETE YqALL Yet/ 18"X 10" CONT'D FOOTIN65 DOOR SGHF 2X8 PT FLOOR J015T5 16" OC, 12X48 GONG. COLUMNS K BIGFOOT5 We g 7ro •ii �� 1/16" ZIP ViALL 5HEATHIN6 NYL 51D1NG 2X6 EXT 5TUD5 16" OC, APPROX GRADE R-30 IN BAY5 2X10 BOX SILL �, 10" POURED CONCRETE YqALL.5 �20"X10" CONT'D FOOTINGS � 0) z ' a a o Y�12X4 KEYYVAY a v o a�Amz F w w Q < O o (3 w i `ca >z<lu O t= utu n! z Lo � 0 z IL a o _ � z to a z Q 3:DOUBLE z z z _E DE50RIPTION HEADER G HUNG 2X10X20 5/16�� 2 DOUBLE HUNG 2X10X32" 2 o }' C3 CA to 3 zul z in o DOUBLE HUNG 2X10X34" 2 DOUBLE HUNG 2X10X34" 2 RIGHT 5LIDING 2X10X33" {2) DOUBLE HUNG 2X10X40" 2 DOUBLE HUNG 2X10X40" 2 FIXED GLA55 2X10X75 1/2" 2 FIXED GLA55 2X10X75 1/2" 2 DATE: DOUBLE HUNG 2X10X32" 2 1/5/2023 )ULE NIDTH HEIGHT R/O DESCRIPTION HEADER THICK SALE R IN 28 " 80 " 30"X52 1/2" HINGED -DOOR PO4 2X1OX33" 2 1 318" L IN 30 " 80 " 32"X82 1/2"- HINGED -DOOR PO4 2X10X35" 2 1 318" R IN 30 " 50 " 32"X82 1/2" HINGED -DOOR PO4 2X10X35" 2 1 3/8" L IN 30 " 80" 32"X82 1/2" HINGED -DOOR PO4 2X10X35" 2 1 318" "=1" R IN 30 " boll 32"X82 1/2" HINGED -DOOR PO4 2X10X35" 2 1 318" R IN 32 " 80 " 34"X82 1/2" HINGED -DOOR PO4 2X10X31" 2 1 318" SHEET: R IN 36 " IbQ " 38"X82 1/2" HINGED -DOOR PO4 2X10X41" 2 1 3/5" R EX 36 " q5 7/8 " 38"Xg81/6" EXT. HINGED -DOOR E21 2X10X41" 2 1 3/4" L/R"1N 54 " SO " 56"X82 1/2" DOUBLE HINGED-DOORP04 2X1OX59" 2 1 318" L/R IN 60 " 60 " 62"X82 1/2" DOUBLE HINGED -DOOR PO4 2X1OX65" 2 1 3/8" L EX 112 " 60 " 14"X63" 1EXT. 5LIVER-6LA55 PANEL 2X10XT7" 2 1 3/4"