Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
9 Pomeroy-2 Final HERS
2015 IECC Building UA Compliance Property Matthew Campagnari 9 Pomeroy Ter Unit 2 Northampton, MA 01060 Weather:Chicopee, MA Pomeroy Duplex 2nd fl 0073-0180-C2_Campagnari_Constr uction_LLC_9_Pomeroy_Ter_Unit Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Campagnari Construction LLC HERS Confirmed 2019-07-24 Rating No:0073_0180 Rater ID:8776762 REM/Rate - Residential Energy Analysis and Rating Software v15.7.3 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. Elements Insulation Levels 2015 IECC As Designed Shell UA Check Ceilings:35.3 27.5 Above-Grade Walls:65.0 63.1 Windows and Doors:52.6 43.1 Overall UA (Design must be equal or lower):152.8 133.6 Mandatory Requirements Shell UA Check PASSES Duct Insulation R-Value Check (per Section 403.3.1)PASSES Window U-Value and SHGC Check (per Section 402.5)PASSES Home Infiltration (Section 402.4.1.2)PASSES Duct Testing (Section 403.3.3)PASSES Mechanical Ventilation (Section 403.6)PASSES Mechanical Ventilation Fan Efficacy (Section 403.6.1)PASSES Mandatory Requirements Check Box (2015 IECC)PASSES This home MEETS the overall thermal performance requirements and verifications of the International Energy Conservation Code based on a climate zone of 5A. (Section 402, International Energy Conservation Code, 2015 edition.) In fact, this home surpasses the requirements by 12.6%. Name Paul J. DellaTorre Signature Organization Noonan Energy Corp Date 1 August 2019 2015 IECC Energy Cost Compliance Property Matthew Campagnari 9 Pomeroy Ter Unit 2 Northampton, MA 01060 Weather:Chicopee, MA Pomeroy Duplex 2nd fl 0073-0180-C2_Campagnari_Constr Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Campagnari Construction LLC HERS Confirmed 2019-07-24 Rating No:0073_0180 Rater ID:8776762 REM/Rate - Residential Energy Analysis and Rating Software v15.7.3 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. Annual Energy Cost $/yr 2015 IECC As Designed Heating 515 395 Cooling 101 99 Water Heating 129 129 SubTotal - Used to Determine Compliance 746 624 Mechanical Ventilation Fan 21 49 Lights & Appliances (minus MechVent)642 576 Photovoltaics -0 -0 Service Charge 33 33 Total 1441 1281 Mandatory Requirements Annual Energy Cost Check PASSES Duct Insulation R-Value Check (per Section 405.2)PASSES Window U-Value and SHGC Check (per Section 402.5)PASSES Home Infiltration (Section 402.4.1)PASSES Duct Testing (Section 403.3.3)PASSES Mechanical Ventilation (Section 403.6)PASSES Mechanical Ventilation Fan Efficacy (Section 403.6.1)PASSES Mandatory Requirements Check Box (2015 IECC)PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2015 International Energy Conservation Code based on a climate zone of 5A. In fact, this home surpasses the requirements by 16.4%. Name Paul J. DellaTorre Signature Organization Noonan Energy Corp Date 1 August 2019 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2015 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2015 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 9 Pomeroy Ter Unit 2, Northampton, MA by Campagnari Construction LLC exceeds the minimum requirements for the 2015 International Energy Conservation Code The 2015 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( “ICC”). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate - Residential Energy Analysis and Rating Software v15.7.3 The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in compliance with Chapter 4 based on Climate Zone 5A and with all mandatory requirements. Building Features Ceiling Flat R-49.0 Duct NA Sealed Attic:NA Duct Leakage to Outside:0.00 CFM @ 25 Pascals Vaulted Ceiling NA Total Duct Leakage:35.00 CFM @ 25 Pascals Above Grade Walls R-21.0 Infiltration:Htg: 528 Clg: 528 CFM50 Foundation Walls NA Window U-Value: 0.270, SHGC: 0.330 Exposed Floor NA Air-Source HP Electric, Htg: 8.5 HSPF. Clg: 14.0 SEER. Slab None Water Heating Heat pump, Electric, 3.53 EF, 50.0 Gal. Name Paul J. DellaTorre Signature Organization Noonan Energy Corp Date 1 August 2019 2015 IECC Certificate 9 Pomeroy Ter Unit 2, Northampton, MA 01060 Building Envelope Insulation Ceiling R-49.0 Above Grade Walls R-21.0 Foundation Walls NA Exposed Floor NA Slab None Infiltration Htg: 528 Clg: 528 CFM50 Duct NA Total Duct Leakage 35.00 CFM @ 25 Pascals Window Data U-Factor SHGC Window 0.270 0.330 Mechanical Equipment ASHP: Electric, Htg: 8.5 HSPF. Clg: 14.0 SEER. DHW: Heat pump, Electric, 3.53 EF, 50.0 Gal. Builder or Design Professional Signature REM/Rate - Residential Energy Analysis and Rating Software v15.7.3 Home Energy Rating Certificate HERS Index: 45 REM/Rate - Residential Energy Analysis and Rating Software v15.7.3 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. General Information Conditioned Area 1358 sq. ft.House Type Apartment, end unit Mechanical Systems Features Air-source heat pump:Electric, Htg: 8.5 HSPF. Clg: 14.0 SEER. Building Shell Features Ceiling Flat R-49.0 Slab None Lights and Appliance Features Interior Fluor Lighting (%)0.0 Range/Oven Fuel Electric TITLE Estimated Annual Energy Cost Use MMBtu Cost Percent Heating 8.3 $355 31% Criteria This home meets or exceeds the minimum criteria for the following: 2015 IECC UA Compliance Conditioned Volume 10864 cubic ft.Foundation Apartment above cond. space Water Heating:Heat pump, Electric, 3.53 EF, 50.0 Gal. Sealed Attic NA Exposed Floor NA Interior LED Lighting (%)100.0 Clothes Dryer Fuel Electric Company Cooling 1.0 $45 4% 2015 IECC Performance Path Bedrooms 2 Duct Leakage to Outside 0.00 CFM25. Vaulted Ceiling NA Window Type U-Value: 0.270, SHGC: 0.330 Refrigerator (kWh/yr)717 Clothes Dryer CEF 2.62 Address Hot Water 2.1 $90 8% Ventilation System Balanced: ERV, 70 cfm, 38.0 watts. Above Grade Walls R-21.0 Infiltration Rate Htg: 528 Clg: 528 CFM50 Dishwasher (kWh/yr)268 Ceiling Fan (cfm/Watt)0.00 City, State, Zip Lights/Appliances 14.5 $624 54% Programmable Thermostat Heat=Yes; Cool=Yes Foundation Walls NA Method Blower door Phone # Photovoltaics -0.0 $-0 -0% Fax # Service Charges $33 3% Total 25.9 $1146 100% Property HERS Matthew Campagnari Rating Type:Confirmed Certified Energy Rater:Paul J. DellaTorre 9 Pomeroy Ter Unit 2 Rating Date:2019-07-24 Rating Number:0073_0180 Northampton, MA 01060 Registry ID:837415640 This home has been inspected and performance tested in accordance with Chapter 3 of the RESNET standards. TITLE Company Address City, State, Zip Phone # 9 Pomeroy Ter Unit 2 Northampton, MA 01060 Rater: Paul J. DellaTorre Registry ID: 837415640Annual Estimates*: Elec(kWh): 7601 C02 emissions(Tons): 4 Energy Savings ($)**: 1857 *Based on standard operating conditions **Based on U.S. DOE designation of a HERS Index of 130 as the 'Typical Existing Home' 45