Loading...
16B-008 (3) -,: ` 'pi. City of Northampton REQUIRED INSPECTIONS i j $-.'�,'!�,�'' �C� 1. Footings and Wall._(( r� �• BUILDING DEPARTMENT 2. Structural Corgi ner kin Place* `m, ' 3. Complete Complete Building* No. 262 Office of the Building Inspector Zoning Form No. 004134 Date 4/14/95 Fee $100 Check# 366 Page, 16B Parcel 8 ,Zone uRB Section 127 ❑ Yes ® No BuiLDING 3 ERmin *Plumbing and Electrical Inspections required THIS CERTIFIES THAT Hebert Construction before Building Inspections . has permission to Raise roof & add 2nd floor, new kitchen & bath 1st floorinspection on Site—Foundations T _ situated on 119 Bridge Road inspection of Plumbing—Rough i,. Inspection of Pumbing—Finish /1) 17 s?7 Provided that the person accepting this permit shall in eve ryrespect conform to the terms of the application on file in this office, and to the Gas Inspection provisions of the Statutes and the Ordinances relating to the Construction, Inspection of Wiring—Rough W4F S/3/79c Maintenance and Inspection of Buildings in the City of Northampton. �� Any violation of any of the terms above noted is an immediate revocation Inspection of Wiring—Finish ' �/` 6-1'S`1 s'7 of this permit.Expires six months from date of issuance,if not started. Building Inspection—Rough el f-r. 6-/;Q- , ,, Note:A certificate of occupancy will be issued by this office upon return Insulation Inspection CI'1'. -7-i %: w of this card signed by the Plumbing,Wiring and Building Inspectors. Building Inspection—Finish (' 1►c 1^n 3 -T Smoke Detectors(Fire Department) /d " I q . A )/k Other THIS CARD MUST BE DISPLAYED IN A CONSPICUOUS PLACE ON THE PREMISES ' " Certificate of Occupancy Building Inspector ,`: V por4(3474? ,.z,v fib o? ) 6/ Q'M 4 cid-/e/6"P tow,r/ /m2°7 �'`..'1 004134 Date Filed y-/ '-145 File No. ZONING PERMIT APPLICATION (510. 2) 1 . Name of Applicant: III/IK/1/:k4ri Address : VS Fo.Frirte.. . Leeds mA, Telephone: ,5- -6-y3S 2 . Owner of Property: , /4,aMe,1,ikbe.7- Address : - yr 'c.4r5feet1 /id Leeds km4 , Telephone: SIG. 5-73 3 . Status-'of Applicant: L caner ') Contract Purchaser . • Lessee Other (expl. n: ) . 4 . Parcel Identification: Zoning Map Sheet# ,/ 3 nparcelf ' , Zoning District(s) (include ov rlays) 10&— Street Address // / 1. r-.*<J,c.— /1/ / . g . Required 5 . Existing Proposed by Zoning Use of Structure/Property ife.S, (if project is only interior work, skip to #6) I 1 Building height �j1'p ` t %Bldg. Coverage (Footprint) /ram, 6V2 Setbacks - front 3 , \ J side L: ,,,yE'`u:iL"' L: i; - rear yr6 V• Lot size /p//ate SF Frontage. .1‘,,o ft Floor Area Ratio cs\V %Open Space (Lot area minus building and parking) 46,/e SC. Parking Spaces "pca,011/ Loading / ,¢ . Signs . Fill (volume & location) �j� 6. Narrative Descri tion of Proposed Work P oject: (Use additional sheets if necessary) - , ) /e ,0,1 o p- /C/+,A�,y� .4" f� I!'2 j- /i4M s 1 AI rum f i iZ er. i�17i AZ' L1 40 (29 1::"GA,, , 07d, , 7. Attached Plans: Sketch Plan ) ' Site Plan . 8 . Certification: I hereby certify that the information contained herein is true and accurate to the best of my knowled e. Date: gial.a. J�f/��j Applicant' s Signature G_11, 4 THIS SECTION FOR OFFICIAL USE ONLY: Approved as presented/based on information presented Denied as presented--Reason: Special' Permit and/or Site Plan Required: Finding Required: Variance Required:90— . . j Signature of Building Inspector Date NOTE: issuance of a zoning permit dons not relieve an applicant's burden to comply with all zoning requirements and obtain ail required permits from the Board of Health,Conservation Commisslon, Dopautmont of Public Wosks and other applicable permit granting authorities. Ie 1•)- I 70 -v t T s 7: C > o � = I' C c zpm e7 z 3 4, o Z • n ^• r, ""l ,,,' rn — O m ,O C > rrl Zoning Miscellaneous Additions,Repairs,Alterations,etc. Tel.No.*3t96-f%.. Alterations iiki:r NORTHAMPTON, MASS, Izre I L/ Iq 9$' Additions }' ,A' APPLICATION FOR PERMIT TO ALTER Repair Garage 1. Location 119 4312-t do 2.d FA re or E-- ✓fA. 0/0i-2 Lot No. 2. Owner's name r 1 AtOc A. I.Ie.6piT /5 411ue r11 ikJ,T Address 3. Builder's name � C.0c271.,c.77o14) *Address' a —44'u SL3C Al/O.E'l Z Mass.Construction Supervisor's License No. �Q'/�7 8 3 Expiration Date , `TC 4. Addition 5. Alteration *OW k>")Lfe'4/ .1 all; .Xs% yC t "ad ,'iIl. ‘"?'4)irk ,( (. �i' "MI) 6. New Porch 7. Is existing building to be demolished? 4i'17MOi %IL' co/ .,/'A/ (,1SPy4r f kfrai.5) 8. Repair after the fire A/C 9. Garage NO No.of cars Size 10. Method of heating o/C Fred F&c CO 14er w4Tef l✓zFi 3C--e- l'(5 L '6/ �d`/�G '�(-5/`d" ( S'�) 11. Distance to lot lines 12. Type of roof JO Yr Ma4'f cJ n�/lV 5 13. Siding house Vi dull 14. Estimated cost ,e•v t/� The undersigned certifies that the above statements are true to the best of his, her knowle e and belief 4C/ aLl)...,a, or-1 ,2/14 - Signature of responsible appilcant Remarks NEWTON ASSOCIATES IN ENGINEERING, INC. 17 OLD NORTH RD. WORTHINGTON, MASSACHUSETTS 01098 (413)238-5925 February 27, 1995 Hebert Construction Co. East St . , Chesterfield, MA NP1fvirr' r- . D R-400 Q �._ R Williamsburg, MA 01096 APR 18 f995 Attention: Michael Hebert DEr CF 8Ui(DING tf SPEC1i0t: Dear M r . Hebert : NORTHAMPTON,M;010E4 In accordance with your request , we have inspected the base- ment walls of the house at 119 Bridge Rd. in Florence, Mass. This inspection showed the walls to be in good condition with a presump- tive bearing capacity of 3000#/ft. minimum. The present basement wall loading is 838#/ft . , uniformily placed . The basement wall loading for the revised structure is 712 #/ft . on the east and west walls, and 689 #/ft . on the north and south walls. None of the basement wall loads are greater than 28% of the presumptive bearing capacity. The detailed inspection report is attached . Sincerely PyTHOF 41471, Donald U NEWTON m o o tp,p'o ;II , P. E . Fs��1STti`��s/�NAL ENG' 1 Of 3 BASEMENT WALL INSPECTION REPORT 119 Bridge Rd . Florence , Mass . 1 .0 PRESENT The basement wall consists of a 25 ft x 25 ft center section with 6 ft front and rear additions to support what appear to have been porches that were later incorporated into the house . The center section is a full , 8 ft high basement , while the additions have only crawl spaces . The center section wall is 9" thick poured concrete that dates to approximately 1910. The concrete was prepared using portland cement and bank run gravel aggregate with mostly 1/2" dia. stones , although occasionally 2" stones are apparent . It was carefully poured and consolidated since there is no evidence of holes , surface stones or other defects . The concrete is very dense and shows no signs of deterioration . There is no evidence of cracking on the inside over the full perimeter . This structure has no floor drain and there is no evidence of water on any of the inside walls . These walls have a presumptive load bearing capacity of30pp #/ft mininum. The front addition is 6 ft x 25 ft and appears to be about the same age as the center section . It does not appear to be anchored to the center section but has not pulled away from it and has not been affected by frost or settlement . There are no cracks visisble in this addition . The rear addition is 6 ft wide but is only 23 ft - 6" long and is inset approximately 9" from either side of the center section . This section was poured with a vertical joint at the center. There are two ( 2 ) vertical cracks apparent on either side of a window opening that is east of the house centerline . The two wall sections do not appear to be anchored to the center section or to each other but show no evidence of shifting due to settlement or frost . The cracks noted above are continuous to grade , but are fine . Hebert Constr. Co . Basement Wall Insp. Report 2/95 2 of 3 The present building dimensions are 25 ft x 37 ft but the rear section is not expected to be used as multi-story in the revised structure . The present foundation loads are as follows : First floor dead load = 4925 lb. = 44 #/ft Exterior walls = 46 #/ft 2nd floor dead load = 44 #/ft Roof load = 44 #/ft Snow load @ 40 psf = 278 #/ft Live load , lst floor @ 40 psf = 278 #/ft 2nd floor @ 30 psf & 1/2 floor area = 104 #/ft 838 #/ft This loading is 28% of the minimum bearing capacity of the foundation. 2 .0 PROPOSED The revised house ( 2 story) will utilize the center and front sections of the foundation . It will have dimensions of 25 ft x 31 ft , an area of 778 sf , and a perimeter of 112 sf . The roof ridge will run north-south and the roof slope will be 8/12 . The south section of the existing house will remain single story and will be tied into the new structure . Because of the steep roof pitch , the snow load component will not exist . In addition , the front and rear foundation wall will have a lower loading from the building components . The revised building foundation loads are as follows: North/south walls East/west walls 1st floor dead load 44 #/ft 44 #/ft 1st floor, Exterior walls 46 "/ft 46 "/ft 2nd floor dead load 44 #/ft 44 #/ft 2nd floor exterior walls 46 #/ft 46 #/ft Gable end walls 23 #/ft - Roof dead load - 46 #/ft Snow load 1st floor live load 278 #/ft 278 #/ft 2nd floor live load 208 #/ft 208 #/ft 689 #/ft 712 #/ft % Minimum bearing capacity 2 24% -Hebert Constr. Co. Basement Wall Insp. Report 2/95 3 of 3 The existing basement walls are fully capable of supporting the revised building weights. FP-T"OFA, 2 DONALD s 49 To Z G. Z c (o ' �TON '° o • s'O/ L ENG�t, I ��1 J l- 6p'. r° >a r2bM IVIq�N NovSE� &ILK HEAD "girl ,o,-/s- 30„toy 2xC, Selig. CELLA 2 — 34414 r } I 8/4Co 5/ee"c" f —� —' %�D, `` 2)C8 G REE,J�o4RD 0-9 „ .4 ri 8"1oxi- I - 4'-/0" viou- C(Z Ww >_ S GAGE CEXI STi�G-> --" -.1 - G'-c," i . • • \ - I 3 Pc (3=ti 17EPTl4) • 1 74//2. - �=-''FNE2 S -XisT„V� /P.C4N 1�Ems/ C8y ar/e s) I-- - / , \ 4xer,v \ �-- ' --- _ •-._ . -- .-..__ [-- -I -5(10At4 WU-) . \. / ,EyisT/�G Ce / \ _ .__. 1 F5/_A Fs \ ,,, I I _, I \ T 1 , t 1 , :-7--- AZ L ,------------\—\\\, \ ' �P 1 1 I I_ 1 1 , 5-,c7/a rl 11- A _ I RJ FD) IIUMN n - 1re,„E i_ 1 — - — — — - - - - - - - - — a al JUN I 4 1995 U �1 DEPT OF BUILDING INSPECTIONS I I I NORTHAMPTON.MA 01060 Sc/iLE.' //41__ / , I 1 1 G -4 I 1 i 1 j 1 Fog M4R K A. /-/E,BEgT I-----441,1 NoR77-41,0P7oN, Ali). /3f.' P WeeE e/ 26-o