Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
15B-038 (6)
BP-2024-0524 228 CHESTERFIELD RD/ COMMONWEALTH OF MASSACHUSETTS 2 SHEPHERDS HOLLOW Map:Block:Lot: CITY OF NORTHAMPTON 15B-038-001 Permit: Alts Renovations Repair PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2024-0524 PERMISSION IS HEREBY GRANTED TO: Project# GEOTHERMAL HT PUMP 2024 Contractor: License: Est.Cost: 25000 DANDELION ENERGY INC 106523 Const.Class: Exp.Date: 12/03/2024 Use Group: Owner: CAPLAN, EMILY&BLOCHER,KYLE Lot Size (sq.ft.) Zoning: RR/URA Applicant: DANDELION ENERGY INC Applicant Address Phone: Insurance: 333 NORTH BEDFORD RD SUITE 220 (860)301-7100 WC 034287768 MOUNT KISCO, NY 10549 ISSUED ON: 04/30/2024 TO PERFORM THE FOLLOWING WORK: GEOTHERMAL HEAT PUMP POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS.Signature: /Z. Fees Paid: $162.50 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Office of the Building Commissioner /,.. The Commonwealth of Massachusetts �`' 1<r ` if Boa d of Building Regulations and Standards FOR Machusetts State Building Code, 780 CMR MUNICIPALITY t>bi USE 41: ."14i er Application To Construct,Repair,Renovate Or Demolish a Revised Mar 2011 0saotiS One-or Two-Family Dwelling '` t/ This Section For Official Use Only Building ermit Number:gP--..2 q "5 d-y Date Applied: 8,r� a.," //Z- y--30-ZDZ Building Official(Print Name) Signature Date SECTION 1:SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 2 Shepherds Hollow Rd Northampton,MA 01062 1.la Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone: Outside Flood Zone? _ Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Kyle Blocher Northampton,MA 01062 Name(Print) City,State,ZIP 2 Shepherds Hollow Rd No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) la Addition 0 Demolition 0 Accessory Bldg. 0 Number of Units Other El Specify:Geothermal Brief Description of Proposed Work2:Install one 4 ton geothermal heat pump,closed loop system and an air source heat pump. SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building $ 1. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical $ ❑Standard City/Town Application Fee ❑Total Project Cost'(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $25000 List: 5.Mechanical (Fire Suppression) $ Total All Fee : $ /', 0 Check No.tLf03Check Amount: ,(l'� Cash Amount: 6.Total Project Cost: $25000 0 Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CSFA-106523 12/3/2024 Wyatt Roberts License Number Expiration Date Name of CSL Holder List CSL Type(see below) R 333 North Bedford Road,Suite 220 No.and Street Type Description Mount Kisco U Unrestricted(Buildings up to 35,000 Cu.ft.) R Restricted 1&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 845-649-6073 JDeVore@DandelionEnergy.com I Insulation Telephone Email address D Demolition „Q 16 5.2 Registered Home Improvement Contractor(HIC) 201508 2023/04/11 Dandelion Energy HIC Registration Number Expiration Date HIC Company Name or HIC Registi art Name 333 North Bedford Road,Suite 220 hkowalski@dandelionenergy.com No.and Street Email address Mount Kisco,NY 10549 860-301-7100 City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes 0 No 0 SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Dandelion Energy to act on my behalf,in all matters relative to work authorized by this building permit application. Kyle Blocher Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Hannah Kowalski of Dandelion Energy 4/25/2024 Print Owner's or Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq. ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" CITY OF NORTHAMPTON SETBACK PLAN MAP: LOT: LOT SIZE: REAR LOT DIMENSION: REAR YARD See Attached SIDE YARD SIDE YARD FRONT SETBACK FRONTAGE The Commonwealth of Massachusetts t* r Deportment of Industrial Accidents 1 Congress Street.Suite 100 f Boston, MA 02114-2017 'p ► ,� wwtw:mass.gor/dia 11 others'('oinpensation Insurance Affidavit:Builders.K ontracterstlaectricians'Plumbers. II)BE FILED 5111 H 1 HE rcR1111'1'1s(::51'1 HOk111. Applicant Infurinatian i'Iease Print Le=ills NaiTte 4Husrncss'Organization Indiwidua' Dandelion Energy Address: 333 North Bedford Road,Suite 220 CltyiStatefZtp: Mount Kisco,NY 10549 Phone#: 860-301-7100 Arent!MI a llfpleyfff?Cheek appropriate het: Type of project(required): t.®I sin a empkryt:nacho 140 employee.troll and VI pant-uml t• 7. D New construction ^r lam a xrk proprietor or p einta'hsp and hat a nu ernpioy e`-.a urimg for me in - e. 0 Remodeling any capacity.(Nu vaster,'comp uuurancr rcywred j 30 I am a 1101Mh iiti doing all wort!!matt.it'.,tscsta p ts'com enaurancc nywred.) 9. ❑Demolition ! 4.0 I asa homeowner and a►tl fie hutng UtMtr:KiUr,to conduct all a uric on rm.property. I will 10 Q Belding addition maw that all contracktn either hat c wtrtt.n'Luenpenwwon m,uranax or arc sole 11.0 Electrical repairs or additions proprietors each no employee, 12.0 Plumbing repairs or additions 50 I seas baneral cuntrattor and I tilt!lured the mitt-contractor%h_sl d on the attached sheet_ These sub-contractor.hate cmpluyeco and hat c waiters'comp.tnrwan-r.t 13❑Root'sub-contractor. repairs 14_11Other Geothermal 6.0 We are a corporation and tb officer.hat c cxan-Ised thee nght of citemplion per MGL c. — 152.4;I141.and at luec all emplo)ac,.[Nu vomiter;comp m,urane'e umutrrtl j *An)applicant that titan ka boa aI mug also till out the section helua shooing thee...takers'compm.411an pulict unfanntaussl. Romeo..nen...Ito%tabaeir via,atlulat tt rnthemi nu they air Burnt:all wink and then htn outside.:toniracto,must submit a ncx.,i hi a%it mdttatlnr>uch 't,,ntractura that eir:ti:this hos must aitsciled an addsrn.nal short shwa ing the name u1 the tub-contr'aat.r.anj stale'bather or nut thus:align:,!tact: ci dig tallte0 .1ur+la%,, nu, cc,.the,. ,lust their at', .r,'.vrnp rxiiwt numlwt I am an employer that is providing wv rAers'compensation insurance for my employees. Below is the polio'and job site in f arrmarfiun. Insurance company Name: New Hampshire Ins Co Policy#or Sell-ins.Lie.# I:rptrattun Datc:: WC 038394824 NY 7/1/2022' _ Job Site Address: 2 Shepherds Hollow Rd Northampton,MA 01062 Con State Zip: - • Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,*25A is a crux' aI violation punishable by a tine up to S1.500.0(1 and'or sox-v►ar imprisonment,as well as civil penalties is the form of a STOP WORK ORDER and a fine of up to 5250.(M).t da against the violator.A copy of this statement lnay be forwarded to the Office of Ins c:stiptatwlns of the DIA for insurance coverage scnticatton. 1 do hereby certify'under the pains and penalties of perjury that the information provialeel above i.►true and correct. Signature �L'[nl"1"a /16G� 1)xlt. 4/25/2024 phone= 860-301-7100 Official use only. Do net write in this area.to be completed be city or town official t'ity or Toss,: Permit/License)1 Issuing:Authority trirele one): I. Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector S.Plumbing Inspector b.Other a Contact Person: Plume#: 1 1 it.... VL/t v11vivI Y v v 1...!1.L. I I 1 ,...J1 IVIr'11.J`,tr1\./I IlJlJI_. 1 I Office of Consumer Affairs and Business Regulation 1000 Washington Street: v Suite 710 Boston. Massachusetts 02118 Home Improvement Contractor Registration Supplement Card _ : DANDELION ENERGY, INC �"� K =z ��A Registration 201508 333 N BEDFORD ROAD, SUITE 220 ` � Expiration: 04/11/2025 MT KISCO, NY 10549 `£ • Update Address and Return Card. THE COMMONWEALTH OF MASSACHUSETTS )ffice of Consumer Affairs & Business Regulation Registration valid for individual use only before the HOME IMPROVEMENT CONTRACTOR expiration date. If found return to: TYPE: Supplement Card Office of Consumer Affairs and Business Regulation Registration Expiration 1000 Washington Street - Suite 710 201508 04111,202E Boston, MA 02118 :LION ENERGY, INC ROBERTS 3EDFORD RD SUITE 220 }i"' • f t: j. r KISCO, NY 10549 .r Not valid without signature Undersecretary 9 a THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs and Business Regulation 1000 Washington Street - Suite 710 Boston, Massachusetts 02118 Home Improvement Contractor Registration � r iii r M Type: Supplement Card 'o _= � Registration: 201508 DANDELION ENERGY, INC Expiration: 04/11/2025 333 N BEDFORD ROAD, SUITE 220 '.► ii S MT KISCO, NY 10549 , — 7 (" Update Address and Return Card. THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs&Business Regulation Registration valid for individual use only before the HOME IMPROVEMENT CONTRACTOR expiration date. If found return to: TYPE: Supplement Card Office of Consumer Affairs and Business Regulation Registration Expiration 1000 Washington Street -Suite 710 201508 �, 04/11/2025 Boston,MA 02118 DANDELION ENERGY, INC ,4t low WYATT ROBERTS ,.. ' (Z Y 333 N BEDFORD RD,SUITE 220 4. d'a Q MOUNT KISCO, NY 10549 ti ' Undersecretary Not valid without signature �a, Ell' Commonwealth of Massachusetts Division of Professional Licensure ~ - a - Board of Building Regulations and Standards Construction.Supervsor t 1 ���� �� CSFA- � 06�23 �., k: Expires: 12/031202� , r�j , WYATT ROBERTS , :° , f 333 NORTH BEDFORD' RD STE 220 °`.- .*. MOUNT KISCO NY 10549 I, ' \ \ . ‘:-\\*.\ 1k71;.:$::.:4::, ' ' t) rej- lc f i r i 6/Y1(j- .4(01,_,., 4 � Commissioner ioner j 1` Aco® CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) 04/19/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Marsh Affinity PHONE AX Marsh Affinity (NC,No,Ext): 800-743.8130 (C,No): a division of Marsh USA LLC. E-MAIL ADPTotalSotuce@marsh.com PO BOX 14404 ADDRESS: Des Moines,IA 50306-9686 INSURER(S)AFFORDING COVERAGE NAIC# INSURER A: New Hampshire Insurance Co. 23841 INSURED INSURER B: ADP TotalSource CO XXIII,Inc. INSURER C: 5800 Windward Parkway it INSURER D: Alpharetta,GA 30005 Alternate Employer: INSURER E: Dandelion Energy Inc INSURER F: 333 N Bedford Rd Mt Kisco,NY 10549 COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADD LSUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTR INSD WVD (MMIDDIYYYY) (MM/DDIYYW) COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ CLAIMS-MADE OCCUR DAMAGE TO RENTED $ PREMISES(Ea occurrence) MED EXP(Any one person) $ PERSONAL&ADV INJURY $ GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ POLICY JECT LOC PRODUCTS-COMP/OP AGG $ OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ (Ea accident) ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE _AUTOS ONLY _AUTOS ONLY (Per accident) $ UMBRELLA LIAR OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ $ WORKERS COMPENSATION PER OTM- AND EMPLOYERS'LIABILITY YIN X STATUTE ER ANYPROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ 2,000,000 OFFICER/MEMBER EXCLUDED? N/A WC 034287768 MA 07/01/2023 07/01/2024 A (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 2,000,000 if yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 2,000,000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space is required) All worksite employees working for Dandelion Energy Inc paid under ADP TOTALSOURCE,INC.'s payroll, are covered under the above stated policy.Dandelion Energy Inc is an alternate employer under this policy. CERTIFICATE HOLDER CANCELLATION Dandelion Energy Inc 333 N Bedford Rd SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Mt Kisco,NY 10549 THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE )D . ACORD 25(2016/03) ©1988-2015 ACORD CORPO ION. All rights reserved. The ACORD name and logo are registered marks of ACORD DANDENE-01 RMANDEL ACORO CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) 9/8/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: York International PHONE 500 Mamaroneck Ave (A/C,No,Ext):(914)376-2200 I(NC,No):(914)376-2891 Suite 220 ADDRtSS:info a@yorkintl.com Harrison, NY 10528 - INSURER(S)AFFORDING COVERAGE NAIC U INSURER A:Hamilton Insurance Designated Activity Company INSURED INSURER B: Dandelion Energy,Inc. INSURERC: 333 N Bedford Rd,Suite 220 INSURER D: Mount Kisco,NY 10549 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTR INSD WVp (MMIDD/YYYY) (MMIDD/YYYY1 A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE X OCCUR '.ENVPKGHI803226-01 9/8/2023 9/8/2024 DAMAGE TO RENTED 50,000 PREMISES(Ea occurrence) $ MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY X 7Pa LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: $ AUTOMOBILECOMBINED SINGLE LIMIT LIABILITY (Ea accident) $ _ ANY AUTO BODILY INJURY(Perperson) $ OWNED SCHEDULED _ AUTOSREp ONLY AUTOS y Ep BODILY INJURY(Per acadent) & _ AUTOS ONLY AUTOS ONLY (Peer ardent)AMAGE A X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 1,000,000 EXCESS LIAB CLAIMS-MADE ENVXSHI207528-01 9/8/2023 9/8/2024 AGGREGATE $ 1,000,000 DED X RETENTION$ 10,000 WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? N/A (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE INC. THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN DANDELION N BL ENERGYd d 0 ACCORDANCE WITH THE POLICY PROVISIONS. 333Mount Kisco,NY 10549 -- AUTHORIZED REPRESENTATIVE ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD NEW EQUIPMENT TO BE INSTALLED: ,N, LOOP 1 GROUND LOOP TIE-IN BASEMENT 1-1/2 IN HDPE 20 GAL OF GLYCOL MSP1 AI SP2 , — SP1 unnY SIT a 317 • eogA S1HP = w NEW N z LINE SET PATH a WH1NEW • J / A NEW STORAGE ^ v c iiiml 1-. i , I I REC ROOM 2t'10'a 1$ UP ]qpt • A COLD ROAM wras 47 Not r • BASEMENT CONTRACTOR NAME: STAMP: PROJECT NAME: PROJECT ID: / \ ?�kp\`N OF MASS le, BLOCHER,KYLE 23-010-0233 ��� DANDELION ,. �: RYAN s� CARDA PROJECT ADDRESS: DESCRIPTION: PAGE: f 2, MECHANICAL H 2 SHEPHERDS HOLLOW RD,NORTHAMPTON,MA No. 55865 01062 NEW EQUIPMENT PLAN 10, SS/ONALE ' 91CLE 1 s:R,�;Sa»AL ENGINEERING VERSION V2022.08 DRAWN BY: MKK DATE: 2023-07-18 SCALE:SEE NTS SIZE:ISO_B_UX17 Dandelion Heat Pump Packaged Unit Performance Ease of Maintenance • Two-stage Copeland®UltraTech® • Real-time performance monitoring and compressor with efficiency values up to advanced diagnostic capabilities with home wifi Ow 4.5/20.9(COP/EER) connection.Comes standard with every unit. • Unique compressor isolation technology • Removable cabinet panels and removable and high-density foam cabinet insulation control box providing easy access to internal for ultra-quiet operation components. • EnergyStar certified and made in the USA • Aluminum microchannel air coil which eliminates • Qualifies for the federal tax credit and the potential for failure due to corrosion, other state/local incentives enhancing reliability and efficiency Ls ---„ ..,,_ - — • Corrosion-proof plastic drain pan and conden- I sate overflow sensor to protect against potential Ioverflows due to clogged condensate drains I • 3-year workmanship warranty and 10-year �: Simple Installation limited parts warranty �`� . , ____-rim, • Vertical air supply with multi-position, • Digital controls which provide a variety of field field selectable left or right side return selectable settings for each installation,and ENERGY STAR • Universal connection sizes for ground loop, advanced safety controls to protect the desuperheater and condensate connections equipment • Variable speed,constant cfm ECM blower • Factory-installed soft start which reduces the designed to adapt to connected ductwork start-up power of the heat pump by 70%. and operate at a fraction of the cost of a • Optional field-installed internal auxiliary heating conventional blower motor Performance Ratings Heating Cooling MODEL LOAD SIZE CAPACITY(BTU/HR) COP CAPACITY(BTU/HR) EER BREAKER SIZE(AMPS) Full 19,000 4.3 27,100 19.9 YT 024 2 Ton 30 Part 15,200 4.8 21,400 28.2 Full 29,100 4.5 41,200 20.9 YT-036 3 Ton 40 Part 23,300 5.1 31,500 31.3 Full 39,900 4.3 53,300 20.2 YT 048 4 Ton 40 Part 32,000 4.9 42,600 29.6 Full 49,200 4.1 64,300 19.3 YT 060 5 Ton 50 Part 37,700 4.6 50,000 28.0 YT 072 Full 6 Ton 56,200 3.8 71,900 18.0 60 Part 45,800 4.4 58,500 24.8 Rated in accordance with AHRI/ISO standard 13256-1,which includes pump penalties www.dandelionenergy.com Dimensions © 1.00 , I © G, a.70 : iii4+ 160r725� am+-- - 160 -- 72 IIP o 6.56 - ♦- o - . .` Enertedh Recommends a Minimum 1 i of 2 to 2.5 feat of service/Installation ni • Aeons at Front and Air Coil Side. j ` 16.0 TOP VIEW TOP VIEW I I� Showing Optional Filter Rack . 0 I IT_.T•om_. -. 4 . P E 0 -..' (I 1.00 r SOURCE HWG' til WATER r WATER 0 OUT IN SOURCE `II, HWG WATER WATER i WATER IN �;� OUT CONFIGURED AS CONFIGURED AS 1 SIDE DISCHARGE BACK DISCHARGE Note:Side and Back Discharge configurations are only available in 036 through 072 models. LEFT VIEW ' FRONT VIEW ;?1"r'"A.W."4 r.5 - sz� ,e''' _' -'14"'. r tz.07,r 1 a ,�W 4,{rC,kn,,ra M4,u;c , : c r u;,.,,� Unit Dimensional Data MODEL WITHOUT WITH RETURN SUPPLY OPTIONAL CONTROL BOX CONTROL BOX AIR FLANGE AIR FLANGE FILTER RACK Al *B C A2 D E F G H J K L M N P R 024 46.0 23.0 26.5 53.25 25.0 20.0 19.1 1.92 3.63 11.62 12.5 7.44 1.05 2.34 3.00 3.63 036-048 54.0 25.4 30.5 61.2 28.0 26.0 23.7 2.34 2.25 16.0 16.0 7.26 1.60 2.34 3.29 2.25 060-072 58.4 25.4 30.5 65.6 32.0 26.0 24.0 2.34 2.25 16.0 16.0 7.26 1.60 2.34 3.29 2.25 Notes: All measurements are in inches. Electrical connect.are 1"for high voltage, 1/2"for low voltage. *B(Unit Width)excludes field installed factory supplied flanges. Ground Low Water Cof Temp Pend Performance Monitoring �319 „, Heat pump comes standard with real-time monitoring to provide the installer .3A:54 ., i m and homeowner with remote insight into system performance.This includes e.r� `s ..- ,,,. real-time efficiency,energy usage,and status of the refrigerant,air,and ----- .. ground loop circuits. " 2.42 "' " _ � .... ;® ,-.a. 34.25 Row RN.T"d www.dandelionenergy.com DANDELION December 22,2023 RE: Compliance with applicable codes and regulations To whom it may concern: Dandelion requires that all design and installation methods and materials comply with all applicable codes and standards, including ANSI/CSA/IGSHPA C448 Series-16(Design and installation of ground source heat pump systems for commercial and residential buildings),M2105 of the 2021 International Residential Code(Ground Source Heat Pump system Loop Piping)and 2021 IECC Residential Provisions with Mass stretch Amendments of 2023(as cited by Ninth Edition of the MA State Building Code 780). We provide a set of internal Design&Installation Standards,Permit Drawings,and Master Service Agreements to enforce this requirement with third party contractors and internal installation crews alike. Therefore,to the best of my knowledge, belief and personal judgment,our permit drawings,design and installation requirements,and scope of work comply with M2105 of the 2023 International Residential Code and 2023 IECC Residential Provisions. If you have any questions,feel free to contact me at rcarda@dandelionenergy.com. Sincerely, Ryan Carda, P.E. Principal Engineer Dandelion Energy, Inc. \\jH OF M ,, �Ctt RYANJ. ,,T. cle it..... i CARDA No.55865 December 22,2023 '%90,rF�..STER� s`� ''/,„;-'sioNAt.EN6\\\\\ iiiiiitll lllll\\\\\ \I, O228 Park Ave S PMB 70212 New York,NY 10003-1502 US DANDELION June 2,2022 RE:Sediment control practices used to install a ground loop as part of a geothermal heating and cooling system installation To whom it may concern: This letter summarizes Dandelion Energy's sediment control practices used during ground loop installation for geothermal heating and cooling applications. In general,Dandelion implements industry-accepted sediment control methods during drilling and trenching activities according to the New York State Department of Environmental Conservation Standard Specifications for Erosion and Sediment Control. The sediment control method(s)implemented on each project vary depending on site-specific conditions, but may include one or more of the following measures: • Mud Processor-Equipment used to manage and process drilling spoils by separating solid and fluid materials removed from the borehole. • Containers-Drilling spoils are typically discharged directly into containers such as heavy-duty woven polypropylene sacks, impermeable 3-ply plastic pools,geotextile filter bags or lined roll-off containers during drilling. • Stockpile Methods-In some instances,drilling spoils or excavated materials from trenching may be temporarily stockpiled and contained using silt fences and/or straw bale dikes to prevent runoff. Excavated material is typically returned to the trench on the same day. • Dust Control-Water is sprayed to wet drilling spoils or excavated materials for dust control as needed. • Trailering-when necessary,tracked rigs will be trailered on and off private property to limit risk of street contamination • Diverter and Dumpster-Some specific drill rigs use a diverter to direct all drill cuttings into a dumpster via a hose.See the attached letter for details and photos of this system. These practices are used to ensure that the highest level of site and environmental protection are achieved as a normal part of system installation. If you have any questions,feel free to contact me at rcardaPdandelionenerev.com. Sincerely, \11111 IInu,,, Ryan Carda, P.E. \\\%-0..OF....7J r Principal Engineer o : • ryG,; Dandelion Energy, Inc. r RYAN J. o CARDA = No.55865 6/2/22 %;�o� FGISTER�� ��`�� %FfsioNAL00 \I� 0333 North Bedford Road,Ste 220 Mount Kisco,NY 10549 DANDELION August 19,2022 RE: Insulation requirements for above grade tie-ins To whom it may concern: In general,when installing geothermal ground loop header piping where it penetrates the building envelope, Dandelion's standard method is to do this below grade.This is not possible for some projects and an above grade penetration must be made through the building envelope.Should this be required for a given project,the following requirements must be met: • Above grade piping shall be installed such that it is completely enclosed and insulated(R10 min)on all sides. • The insulated enclosure shall extend from the above grade building entry point to the bottom of the header trench. The installation of above grade piping in an insulated enclosure according to our Design&Installation Standards will provide the necessary protection such that it will have the same performance and service life expectancy of a standard installation. If you have any questions,feel free to contact me at rcarda@dandelionenergy.com. Sincerely, Ryan Carda, PE Principal Engineer Dandelion Energy,Inc. \\"uuuuu,i,/i \\\` .0 OF MAs/,,, " (f\e4.... : RYAN J. ,,R,= o CARDA -"`. No.55865 - 8/22/22 '',9°F gF�ISTER.°'F`'�.,. '//,,FSS/ONAL ENG�\\\ 0 333 North Bedford Road,Ste 220 Mount Kisco,NY 10549 DANDELION August 19,2022 RE: Header Piping Installation Standards In terms of geothermal heat pump system design and performance,lateral header piping is not relied on for heat transfer capacity.The sole purpose of header piping is to carry the fluid from the ground loop to the heat pump and back.As such, Dandelion's header pipe installation requirements are as follows: • The ground loop header piping and manifold shall be located in an exterior trench that runs from the borehole location(s)to building entry point. • The target burial depth for the header piping and manifold is 2 ft below grade,but anywhere between 1-4 ft is acceptable. o The minimum allowable burial depth for insulated header piping shall be 12 inches below grade. o Whenever the header burial depth is less than 4 ft,freeze protection to 15°F is required. o To achieve a 15F freeze protection value,25%propylene glycol shall be used. • Propylene glycol is added to the system as part of the flushing and purging process during the heat pump installation phase of the project. Using the Kusudah-Achenbach equation published in IGSHPAs Residential and Light Commercial Design and Installation Manual to predict soil temperature as a function of soil type,location,time of year and burial depth,it can be shown that the soil temperature at a 1 ft burial depth will not fall below 25-30°F in this region.The requirement to freeze protect with 25%propylene glycol will provide a 10-15°F buffer between the minimum expected soil temperature and the freeze point of the circulating fluid. In order to protect the header piping from damage due to work by other trades, Dandelion requires the installation of warning tape and tracer wire in the trench.Additionally,each customer is given a scaled and dimensioned as-built drawing that shows the location of the borehole(s)and header trench on the property.These measures help to locate and identify the ground loop piping when necessary. As long as the system is installed in accordance with the requirements above,it will perform according to our design specifications and will not be at risk of damage due to freezing or damage. If you have any questions,feel free to contact me at rcarda@dandelionenergv.com. Sincerely, Ryan Carda,P.E. Principal Engineer Dandelion Energy, Inc. \\\"""""//// N OF M iflee....f5s '` RYANJ. ',,A= o i CARDA No.55865 i"- 8/22/22 '', ge4ceFGISTERE°'��Q\' ''%FSS/ONAL Ew",�\`‘‘ \I� O333 North Bedford Road Suite 220 Mount Kisco,NY 10549 DANDELION October 19,2022 RE: Leak Detection& Emergency Shutoff The purpose of this memo is to address the requirements for geothermal heat pump system installation in the state of Massachusetts,specifically Section 9.2, Leak Detection, Emergency Shut-Offs,and Makeup Fluid in the DEP's Guidelines for Ground Source Heat Pump Wells,which states: The GSHP system shall have an automatic shutdown device(s)to minimize refrigerant,antifreeze or oil leaks in the event of a pressure/fluid loss. The shutdown mechanism shall be such that the system can only be reactivated by the GSHP system vendor or other qualified service representative that is qualified to detect and fix(if possible)the leak and conduct a post repair pressurization test. The GSHP that has been shut down due to fluid/pressure loss shall not be reactivated until the final pressurization testing described below in Section 9.6 has successfully been completed. The ability to reactivate the GSHP system that has been shut down due to a pressure/fluid loss shall not be provided to unqualified persons, including the home/building owners/occupants.A makeup fluid tank for either closed-loop or DX GSHP systems shall only be operated manually. The concern is that an automatic makeup fluid injection system could potentially result in the prevention of the activation of the automatic shutdown device in the event of a system fluid leak, thereby resulting in the release of additional refrigerant or antifreeze. To meet the provisions of this requirement, Dandelion: • Exclusively installs closed-loop systems using methods and materials that comply with ANSI/CSA/IGSHPA C448.0-16. • Performs a leak test according to ASTM F2164 to ensure that no leaks are present in the system prior to startup. • Requires the use of pressurized flow centers in our systems,which will not produce flow through the ground loop in the event of a leak. • Requires the installation of geothermal heat pumps that include a lockout alarm(s)in the sequence of operations to disable the compressor and circulating pumps in the event of loss of flow through the ground loop. • Does not install or make provisions for makeup fluid devices in our system. Therefore,when installed according to our Design and Installation Standards,all systems installed by Dandelion meet the requirements of Section 9.2 Leak Detection, Emergency Shut-Offs,and Makeup Fluid. If you have any questions,feel free to contact me at rcardaPdandelionenergv.com. Sincerely, Ryan Carda, P.E. \\�` H OF lyqs' Principal Engineer 4ryG i Dandelion Energy, Inc. 1! RYAN J. T= CARDA "`. No.55865 \ y .9F� Ep :'�Q .....'STER......:�F F ,,SS�ONAl06 \\. 10-19-2022 j O333 North Bedford Road Suite 220 Mount Kisco,NY 10549 PERFORMANCE RATINGS(AHRIII SO 13256-1) COOLING HEATING PRESSURIZED RETURN AIR DUCT MODEL CAPACITY FLOW CENTER CONNECTION W CAPACITY(BTUIHR) EER CAPACITY(BMW) COP FULL LOAD 27.100 19.9 19.000 4.3 S VIBRATION BREAK YT-024 I AND FILTER RACK) PART LOAD 21.400 28.2 pUN Ill liry YT-036 FULL LOAD 41.200 20.9 29.100 4.5 a �,0aV�N-OFpgf4C PART LOAD 31.500 31.3 23.300 5.7 R c` i.;'' `*% FULL LOAD 53.300 20.2 39 900 4.3 EXPANSION TANK d -i I RYAN J. ';,�„ T-0 Y48 N a PART LOAD 42.600 29.6 32 000 4.9 i a -" NoC.A5 865 i _ YT-060 FULL LOAD 64,300 19.3 49.200 41 PART LOAD 50.000 28.0 37.700 4 6 -. E 4/11/22 S,,I.\.46ISTEPE%',,4`� FULL LOAD 71.900 18.0 56,200 3 8 w '''',frs70NAL 10,`` YT-072 PART LOAD 58.500 24.8 45,800 44 `�X 'p°nnnuWIll �n x xu ROUGH GRADE �i -i ♦- � x / \ � � x / x ACCESS SEAL BUILDING ENTRY • \ x PANEL D PER D&I STANDARDS ✓ • I ICI A • 1 FT. RECOMMENDED - ACCESS icmiPANEL CHECK VALVE - (WHEN REQUIRED, SEE NOTES) • G-U-4.4-4—Th - LO ISOLATION BALL VALVES (REQUIRED) • • D _ S . 4. e A A ♦ I—III—III—I 1I— LEGEND ' F-a-I AIR SEPARATORl `rY SYSTEM PRESSURIZATION DETAILS CONDENSATE TO J(5 BALL VALVE-MANUAL RANGE MIN. MAX. APPROVED PUMP OR DRAIN PER AHJ(TRAP REQUIRED) START-UP PRESSURE 30 P51 60 P51 DRAIN VALVE-MANUAL _____y___ FLEXIBLE PIPING NOTES: '"11I't'11'I' CONNECTION DANDELION AIR OPERATION UM ITS CZyy 90°ELBOW WITH PARAMETER COOLING HEATING • LEFT SIDE RETURN SHOWN.UNIT CAN BE CONFIGURED FOR EITHER LEFT-OR RIGHT-HAND RETURN.CONNECTIONS y PT/SENSOR PORT MIN EAT 60'F 45•F MIRRORED FOR RIGHT HAND CONFIGURATION. 1-12 :1-1TEE • APPROVED INTERIOR PIPING MATERIALS:HDPE,PEX AND/OR RUBBER HEATER HOSE.REFER TO DANDELION'S DESIGN& CONNECTION-GENERAL MAX EAT S00•F 80•F INSTALLATION STANDARDS FOR SIZING REQUIREMENTS. PIPING MIN EWE 30'F 20•F SUPPLY-RETURN LINE SIZES SELECTED PER DANDELION'S DESIGN AND INSTALLATION STANDARDS. -♦• PIPING,TUBING, MAX EWE 110•F 90•F • ALL INTERIOR PIPING INSULATED WITH CLOSED-CELL INSULATION G MIN.THICKNESS). 4- HOSE-GENERAL • THE USE OF CHECK VALVES IS REQUIRED WHEN MULTIPLE HEAT PUMPS ARE CONNECTED TO A COMMON(SHARED)GROUND MIN WATER FLOW 2.5 GPM/TON LOOP. fl.-s COUPLING-MALE x • SEE SHEETS 2,3,AND 4(OF 4)FOR ADDITIONAL DANDELION SYSTEM REQUIREMENTS. FEMALE MAX WATER FLOW 3.5 GPM/TON MIN AIR FLOW 300 CFM/TON 'L II /I EXPANSION TANK CONTRACTOR NAME: PROJECT NAME: PROJECT ADDRESS: 2 Shepherds Hollow Rd DESCRIPTION: Kyle Blocher INTERIOR PIPING(DANDELION YT) \I� Northampton,MA 01062 DANDELION MULTI-POSITION VERTICAL PACKAGED VERSION V2022.04 PROJECT ID: 00003779 DATE: 4/24/2024 SCALE:NTS SIZE:ISO_B_11 X 17 HEADER PIPE SIZE PER _ / OUCH GRADE DESIGN DOCUMENTS / STEP-DOWN, R I—I I I�/\//�/\//\—I REVERSEE HEADER RETURN HEADER STEP-DOWN,STEP-UP REVERSE-RETURN HEADER �II—I. / II UNDISTURBED SOIL VERTICAL BOREHOLE(QTY AND • (PER D&I STANDARDS) El II\ \/— � SPACING PER DESIGN DOCUMENTS) 4. -III /I I I—I 1 Kl=I.I NO s 1-1I I'\ �I I I- �M 2 FT. -III-� \�1=1 Idle TARGET DEPTFF /`III- BACKFILL 1111 (SEE NOTES)I III -III—i\ �I I-- I-III/\/\/\/ II= III—I\ �F\�\\�\ III—II APPROX. 6 IN. GRANULAR BACKRLL —III ' '-^••"' -•• I I - (NO ROCKS OR LARGE CHUNKS) -III—� .1:�. ._�:; • , I I Z I 1-1 I I-:v ;�:. CALCULATED �— =+' III BORE J�� DEPTH HEADER PIPING— ' TRENCH TFTAII • TRENCHING NOTES. THE TARGET HEADER PIPING BURIAL DEPTH IS 2 FT BELOW GRADE, BUT ANYWHERE BETWEEN 1-4 FT IS ACCEPTABLE. • AS PREVIOUSLY INDICATED, THE MINIMUM ALLOWABLE BURIAL DEPTH FOR HEADER PIPING IS 12 INCHES BELOW GRADE. HEADER PIPE SIZE _ PER DESIGN DOCUMENTS „. `\p`,wwnn LOOP SUPPLY LOOP RETURN �U-BEND QTY AND PIPE SIZE ,` �N OF M (FROM BUILDING) (TO BUILDING) C-C SPACING PER PER DESIGN DOCUMENTS `.=it.,.-'•� •'"^'r4�yG DESIGN DOCUMENTS 'Ir RYAN J. ':' GROUND LOOP LAYOUT DETAIL o` CARDA l U: •N_ HEADER PIPING DFTAII No.55865 GENERAL NOTES* e•.9 Eo.;rl• ALL , y'D\ef6isTEa.. t • ALL GROUND ROUND PIPELOOP PIPING FITTINGS/CONNECTIONS MIN. 160 PSI RATING MADE VIA HEAT FUSION(PE 3608 OR 4710) PERER ICSA/IGSHPA AN %CSA/IGSHPA8.0-16, SECTION C4480-16, SECTION 25.4.2 5/26/22 ,f,J,,,ONAIE*c''°' • MINIMUM BORE SPACING AND CALCULATED BORE DEPTH PER LOOPLINK RLC • MIN. SEPARATION DISTANCE FROM ALL STRUCTURES AND UTILITIES (FOUNDATION, GAS, SEWER, SEPTIC, PROPERTY LINES, ETC.) IS 10 FT., SYSTEM ANTIFREEZE MUST MEET OR EXCEED AHI BUILDING CODES UNLESS OTHERWISE SPECIFIED BY THE AHJ. . INSTALL R2 (MIN.) PIPE INSULATION ON HEADER PIPING WHEN CROSSING A WATER/SEWER LINE CONCENTRATIONS BELOW CORRESPOND WITH A FREEZE POINT=15°F • FULL LENGTH GROUTING REQUIRED, 1.20 BTU/HR-FT-F GROUT THERMAL CONDUCTMTY VALUE ANTIFREEZE CONCENTRATION% • HEADER PIPING MUST BE LAID OUT IN REVERSE-RETURN FASHION AS INDICATED IN THE HEADER DETAIL DRAWING. ANTIFREEZE TYPE BY VOLUME • ALTERNATIVE PIPING LAYOUT/DESIGN MUST BE PRE-APPROVED BY DANDELION. PROPYLENE GLYCOL 25% • SEE SHEETS 1, 3, AND 4 (OF 4) FOR ADDMONAL DANDELION SYSTEM REQUIREMENTS. • PRIOR TO STARTUP, THE GROUND LOOP SHALL BE FLUSHED AT 2 FPS TO REMOVE AIR/DEBRIS USING A 1.5 HP PURGE PUMP HEAT TRANSFER FLUID MUST COMPLY WITH ANSI/CSA/IGSHPA C448.0.16,SECTION 5.7 CONTRACTOR NAME: PROJECT NAME: PROJECT ADDRESS: 2 Shepherds Hollow Rd DESCRIPTION: Kyle Blocher Northampton, MA 01062 GROUND LOOP AND HEADER PIPING _4/ DANDELIOlii VERSION V2022.05 PROJECT ID: 00003779 DATE: 4/24/2024 SCALE:NTS SIZE:ISO_B_11 X 17 (NEW)HEAT PUMP ELECTRICAL PANEL NOTES: REFER TO TABLE FOR BREAKER REQUIREMENTS • ELECTRICAL WORK MUST MEET OR EXCEED ALL APPLICABLE (EXISTING)MAIN ELECTRICAL PANEL BUILDING&ELECTRICAL CODES • WHEN THE DISTANCE FROM THE SERVICE PANEL TO THE HEAT PUMP L i IS GREATER THAN 100 FT,CONSULT WITH THE ENGINEERING TEAM < a • FOR FURTHER REVIEW. HEAT PUMP • SEE SHEETS 1,2,AND 3(OF 4)FOR ADDITIONAL DANDELION SYSTEM L a REQUIREMENTS. 'IEEE —E) i u ' ��E`�HOFMgf,,„y. 411111111 a • 'a? RYANJ. = L ma • U AUX HEATER No.55865 L 8/16/21 �''o°F'PEG EAE�'�4,, '''fJS/ONALEN,\�`, nin,m ", Cod r- P( o J1:1 pR Rc Rh O G G C 0 Y 1 V1 W1 I HEAT PUMP Y2 W2 O Y2 THERMOSTAT TERMINAL BLOCK 0/B ACC- O COM PEK ACC+ 0 0 C�) \ / .„1/ O DH OWl ECOBEE THERMOSTAT(NEW) CONDENSATE PUMP BREAK(C)WIRE IF CONDENSATE BACKS UP OR MALFUNCTIONS HEAT PUMP ELECTRICAL SPECIFICATIONS AUX HEAT ELECTRICAL SPECIFICATIONS(WHEN APPLICABLE) VOLTAGE/ LRA W/SOFT VOLTAGE/ AUX HEAT KW AUX HEAT AUX HEAT MODEL PHASE/HZ FLA(AMP) LRA(A) START(A) MCA(A) MOP(Al MODEL PHASE/HZ (240V) AMPS 240V) AUX HEAT MCA(A) MOP Y1-024 230/1/60 209 583 17.5 23.8 35 YT-024 230/1/60 5 20.8 26.0 30 YT-036 230/1/60 24.8 83.0 249 28.7 40 YT-036 23011/60 10 41.7 521 60 YT-048 230/1/60 319 1040 312 37.2 50 YT-048 230/1/60 10 41.7 521 60 VT-060 230/1/60 395 152.9 459 46.3 70 YT-060 230/1/60 10 41.7 521 60 YT-072 230/1/60 421 172.9 538 49.5 70 YT-072 230/1/60 10 417 521 60 CONTRACTOR NAME: PROJECT NAME: Kyle Blocher PROJECT ADDRESS: DESCRIPTION: 2 Shepherds Hollow Rd ELECTRICAL/THERMOSTAT/CONDENSATE DANDELIONNorthampton,MA 01062 PUMP WIRING(DANDELION YT) MULTI-POSITION VERTICAL PACKAGED VERSION V2021.08 PROJECT ID: 00003779 DATE: 4/24/2024 SCALE:NTS SIZE:ISO_B_11 X 17 Dandelion Energy GSHP Design Report Project: [23-010-0233, Blocher] (Project ID:33165) Prepared: 19-J u I-2023 Prepared By: Madison Knox ink by Geo-Connections.Inc Dandelion Energy System Loads System Loads or Peak Loads are calculated based on a variety of details for an individual residence. Assumed occupancy levels, the number of appliances operating, the number of doors & windows and the tightness of the construction all contribute to the amount of energy required to maintain the thermostat set points given the historical extreme weather conditions in your area. The peak loads used in this report were provided as listed in the following table. 1 kBtu/hr= 1 000 Btu/hr Total Total Heating Load Cooling Load Zone (kBtu/hr) (kBtu/hr) Zone SHF System 1 (Whole Home) 37.92 28.14 0.910 37.92 28.14 1 of 7 Mt Kisco, New York Dandelion Energy Equipment Schedule Based on the provided loads, the recommended heat pump schedule for this system is as follows: 1-High Cap. Low Cap. ! 1 kBtu/hr= 1,000 Btu/hr Heat ` Cool 1 Water< Air' Cap. Cap. Flow low P1TY (kBtu/hr) ( p.tu,lh ,. t^t3R` -Fran. Dandelion Energy - Enertech 40.50 48.20 12.0 1,790 System 1 (Whole Home) Multi-Position Vertical YT-048 1 33.80 40.28 High Capacity Totals 40.50 48.20 12.0 Low Capacity Totals 33.80 40.28 - 1. All capacities shown are total. 2. When applicable,hydronic source and load water flows are assumed equal. 3. Air flow rates are reported on a per heat pump basis. For total air flow in a zone,multiply the reported air flow by quantity. 2 of 7 Mt Kisco, New York Dandelion Energy System 1 (Whole Home) Zone Details The peak loads for each individual zone are used to calculate the total amount of heating & cooling capacity required for a space based on the set points and the climate data for your area. Peak Heating Load 37,917 Btu/hr Peak Cooling Load 28,143 Btu/hr Heating Set Point 72 °F Cooling Set Point 72 °F Heating Offset 0 Btu/hr Space SHF 0.910 GSHP Selection The ground source heat pump below has been selected to maintain comfortable heat- ing & cooling for this zone. Manufacturer Dandelion Energy Model Enertech Multi-Position Vertical YT-048 Heat Pump Type Water to Air Capacity Dual Capacity # Heat Pumps 1 Installed Capacity Check The installed capacity check describes the efficiency and total heating/cooling capacity of the selected ground source heat pump system. This information is used to ensure proper sizing of equipment based on the load represented by this zone. Heating (High Capacity) Cooling (High Capacity) Heating Capacity 40,500 Btu/hr Total Cooling Capacity 48,200 Btu/hr % Sizing 106.8% Sensible Cooling Capacity 36,150 Btu/hr % Energy From Geo 99.9% % Oversizing 41.2% Installed COP 3.89 Installed EER 14.39 Balance Point Temp. -3.0 °F Heating (Low Capacity) Cooling (Low Capacity) Heating Capacity 33,800 Btu/hr Total Cooling Capacity 40,277 Btu/hr % Sizing 89.1% Sensible Cooling Capacity 30,208 Btu/hr Installed COP 4.25 % Oversizing 18.0% Installed EER 20.96 3 of 7 I Mt Kisco, New York Dandelion Energy System 1 (Whole Home) Zone Operating Summary The Zone Operating Summary describes equipment runtime and the total annual power consumption for the GSHP operating in this zone. Heating Cooling High Capacity Runtime 138 hrs High Capacity Runtime 4 hrs Low Capacity Runtime 2,099 hrs Low Capacity Runtime 688 hrs Supplemental Bin Hours 13 hrs Dual Fuel Bin Hours 0 hrs Heat Pump Energy Use 5,317 kWh Heat Pump Energy Use 1,456 kWh Pumping Energy Use 451 kWh Pumping Energy Use 139 kWh Supplemental Energy Use 15 kWh Dual Fuel Energy Use 0 kWh GSHP Operating Cost Breakdown for Zone Name Based on the annual power consumption of the system and the price per kilowatt hour in your area the estimated cost to maintain the set points for this zone are as follows: Heating Cooling HP Cost $1,276.25 HP Cost $349.57 Supplemental Cost $3.67 Pumping Cost $33.52 Dual Fuel Cost $0.00 Total Cost $383.09 Pumping Cost $108.25 Total Cost $1,388.18 I 72.1% HP Heating Cost 16.1% Pumping Cost-Heating EMI 0.2% Supplemental Heating Cost 19.7% HP Cooling Cost I 1.9% Pumping Cost-Cooling 4 of 7 Mt Kisco, New York Dandelion Energy Back-Up System Details Supplemental System Details Supplemental systems operate at the same time as the geothermal heat pump and provide additional heat when the space load is greater than the system capacity. Supplemental System Type Electric Resistance COF 1.0 Zone Load and Operating Profile 900 54 c. 800 700 42 . r- j 600 - - - 36-°y o �a c^• 500 _ 308 .• c my 400 24i r* ro Q• 300 P, 18=3 v x 200 12 a 100 � � � I� � ,. 6 in 0 N O N O N O N 2 N O ry M N pp N Si pp O r O N p N Temperature(°F) - Heating Load - Low Capacity Heating Operation •• High Capacity Heating Operation - Cooling Load - Low Capacity Cooling Operation •• High Capacity Cooling Operation I Supplemental Heating I GSHP Heating I GSHP Cooling Heating Cooling +eating Start OAT 57.0 °F Cooling Start OA l 65.0 °F High Capacity Runtimc 138 hr High Capacity Runtime 4 hr Low Capacity Runtimc 2,099 hr Low Capacity Runtime 688 hr Supplemental Bin Hours 13 hr 5 of 7 I Mt Kisco, New York Dandelion Energy Vertical Bore 15ft cc Earth Temperature Data Location Deep earth (below 20ft) temperature is a function of the average annual air tempera- ture in your region and remains relatively constant regardless of season. Deep Earth Temp (Tc) 53.0 °F Formation Details The thermal properties of your formation are based on the formation's composition and have a direct impact on the scale of your loopfield. Thermal Conductivity 1.49 Btu/hr ft °F GHEX Summary Heating is dominant. Grout is used inside of all bores in order to protect the deep earth environment from surface contaminants and to provide a more effective contact surface with GHEX piping that optimizes heat transfer between the fluid pumped through your GSHP and the earth. Grade Grout T.C. 1.20 Btu/hr ft °F _Backfill ' ''•.,'••.'••..''•.'• __•.'••.`.;•. .�•, •.;'.; '+'„_• MIN 0 Formation =___ \.. === EWTM( 90.0 °F Q Granular Backfill l - D Grout = Bore Diameter (D ) 5.00 in GHEX Pipe 1.25"DR13.5 HDPE 4710DR13.5 nrows(4 max.) 5, 1 2 ... - = Bores in Series (NBIS) 1 () 0 = LB Layout Rows (prows) 1 f—SB--I -_ S +� - Bores per Row 1 2 0 0 j __ e = Number of Bores 1 to .�^ -�� �+ - - � - co l e -_ = Bore Spacing (SB) 15.0 ft m -D B TOP VIEW DETAIL Design Depth (LB) 387 ft (GENERIC) (GENERIC) Header Pipe 1.50"DR 11.0 HDPE 4710 DR11 6 of 7 I Mt Kisco, New York Dandelion Energy Vertical Bore 18ft cc Earth Temperature Data Location Deep earth (below 20ft) temperature is a function of the average annual air tempera- ture in your region and remains relatively constant regardless of season. Deep Earth Temp (TG) 53.0 °F Formation Details The thermal properties of your formation are based on the formation's composition and have a direct impact on the scale of your loopfield. Thermal Conductivity 1.49 Btu/hr ft °F GHEX Summary Heating is dominant. Grout is used inside of all bores in order to protect the deep earth environment from surface contaminants and to provide a more effective contact surface with GHEX piping that optimizes heat transfer between the fluid pumped through your GSHP and the earth. Grade _______•_________ ___ _ _ Grout T.C. 1.20 Btu/hrft °F 1- - -__-::: : : . `:I_` EWTMIN 30.0 °F Backfi l Formation -- EWTMAX 90.0 °F 0 Granular Backfill ----- El Grout __= Bore Diameter (Dr) 5.00 in -_-- GHEX Pipe 1.25"DR13.5HDPE4710DR13.5 nr°ws(4 max.) m I 1 2 ... Bores in Series (Nell) 1 1 0 00 - = LB Layout Rows (nrows) 1 o �—SB-� Bores per Row 1 2 0 0—f— SB __ Number of Bores 1 cn SB -------- Bore Spacing (SB) 18.0 ft m° 3.4 O1 DB- I TOP VIEW DETAIL Design Depth (LB) 387 ft (GENERIC) (GENERIC) Header Pipe 1.50"DR 11.0 HDPE 4710 DR11 7 of 7 I Mt Kisco, New York wrightsofta Building Analysis JJob: 23-010-0233 Entire House By: Dandelion Energy 333 North Bedford Road,Sute 220,Mout Kisco,NY 10549 Phone:833-GEO-4ALL Email:design@dardelionenergy.com Web:www.dardelionenergy.com Pro'ect Information For: Kyle Blocher 2 Shepherds Hollow Rd,Northampton,MA01062 Design Conditions Location: Indoor: Heating Cooling Westfield-Barnes,MA,US Indoor temperature(°F) 72 72 Elevation: 271 ft Design TD(°F) 66 16 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 29.2 29.5 Dry bulb(°F) 6 88 Infiltration: Daily range(°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btuh/ft2 Btuh %of load Walls 4.0 16267 33.9 Ducts Glazing 33.5 10796 22.5 Doors 6.6 1619 3.4 Infiltration Ceilings 1.1 1958 4.1 Walls Floors 2.1 4909 10.2 Infiltration 2.6 9814 20.4 Ducts 2678 5.6 Piping 0 0 Floors Humidification 0 0 Ventilation 0 0 Ceilings Adjustments 0 Glazing Doors Total 48041 100.0 Coolin• Component Btuh/ft2 Btuh %of load Walls 1.0 4187 16.3 Glazing 45.5 14657 57.2 Walls Internal Gains Doors 2.7 663 2.6 Ducts Ceilings 0.8 1333 5.2 IOtherion Floors 0.1 306 1.2 Ceilings Infiltration 0.3 1237 4.8 i Doors Ducts 1117 4.4 Ventilation 0 0 Internal gains 2120 8.3 Blower 0 0 Adjustments 0 Glazing Total 25621 100.0 Latent Cooling Load=2522 Btuh Overall U-value=0.145 Btuh/ft2-°F, Window/FloorArea=8.6% Data entries checked. wrightsaft- 2023-Jrt-1912:18:24 ►.. ^M° , • Right-Suite®Universal 2023 23.0.01 RSU63755 Page 1 ACC ...DesigMarual J[23-010-0233,Kyle Blodier].n. Calc=MJ8 Front Door faces:NE +I+ wrightsoft Building Analysis Job:: e. 23-010-0233 (Unconditioned) By: Dandelion Energy 333 North Bedford Road,Stile 220,Mount Kisco,NY 10549 Phone:833-GE0-4ALL Email:design@dardelionenergy.com Web:v✓wwdandelionenergy.com Pro-ect Information For: Kyle Blocher 2 Shepherds Hollow Rd,Northampton,MA01062 Design Conditions Location: Indoor: Heating Cooling Westfield-Barnes,MA, US Indoor temperature(°F) 72 72 Elevation: 271 ft Design TD(°F) 66 16 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 29.2 29.5 Dry bulb(°F) 6 88 Infiltration: Daily range(°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 • Heatin• Component Btuh/ft2 Btuh %of load Walls 0 0 0 Glazing 0 0 0 Doors 0 0 0 Ceilings 0 0 0 Floors 0 0 0 Infiltration 0 0 0 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 0 0 Coolin• Component Btuh/ft2 Btuh %of load Walls 0 0 0 Glazing 0 0 0 Doors 0 0 0 Ceilings 0 0 0 Floors 0 0 0 Infiltration 0 0 0 Ducts 0 0 Ventilation 0 0 Internal gains 0 0 Blower 0 0 Adjustments 0 Total 0 0 Latent Cooling Load=0 Btuh Overall U-value=0.177 Btuh/ft2-°F, Window/FloorArea=2.8% WARNING:window to floor area ratio=2.8%-less than 5%. - w rig htsaft` 2023-Jul-1912.18:24 �. ,..,^.--,o-o-, Right-Sute®Universal 2023 23.0.01 RSU63755 Pa e 2 ACCA g DesigrdManal J[23-010-0233,Kyle Blocher].rup Calc=MJ8 Front Door faces:NE Building Analysis Jae 23-010-0233 +!+ wrightsoft Con by Other By: Dandelion Energy 333 North Bedford Road,Sute 220,Mount Kisco,NY 10549 Phone:833-GEO-4ALL Email:design@dardelionenergy.com Web:wwwdandelionenergy.com Pro.ect Information For: Kyle Blocher 2 Shepherds Hollow Rd,Northampton,MA01062 Design Conditions Location: Indoor: Heating Cooling Westfield-Bames,MA,US Indoor temperature(°F) 72 72 Elevation: 271 ft Design TD(°F) 66 16 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grill)) 29.2 29.5 Dry bulb(°F) 6 88 Infiltration: Daily range(°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btuh/ft2 Btuh %of load Walls 6.4 4679 46.2 Other Glazing 0 0 0 I Infiltration Doors 0 0 0 / Ceilings 3.2 218 2.2 •:.., Floors 7.3 3678 36.3 Walls °c .. Infiltration 4.2 1466 14.5 Ducts 83 0.8 Piping 0 0 Humidification 0 0 Floors Ventilation 0 0 Adjustments 0 Ceilings Total 10124 100.0 Coolin• Component Btuh/ft2 Btuh %of load Walls 0 0 0 Glazing 0 0 0 Doors 0 0 0 Ceilings 0 0 0 Floors 0 0 0 Infiltration 0 0 0 Ducts 0 0 Ventilation 0 0 Internal gains 0 0 Blower 0 0 Adjustments 0 Total 0 0 Latent Cooling Load=0 Btuh Overall U-value=0.171 Btuh/ft2-°F, Window/FloorArea=0.0% WARNING:window to floor area ratio=0.0%-less than 5%. - wr•i, ••ghtsoft"' 2023-J11-1912:18:24 h ....- • i---- Right-Suite®UriversaI 2023 23.0.01 RS1163755 Page 3 Aet ..Design\Marual J[23-010-0233,Kyle Blocher].rup Calc=MJ8 Front Door faces:NE +I+ wrightsoft Building Analysis D be. 23-010-0233 System 1 By: Dandelion Energy 333 North Bedford Road,Stile 220,Moult Kisco,NY 10549 Phone:833-GE0-4ALL Email:design@dardelionenergycom Web:wwwdandelionenergy.com Pro'ect Information For: Kyle Blocher 2 Shepherds Hollow Rd,Northampton,MA01062 Design Conditions Location: Indoor: Heating Cooling Westfield-Barnes,MA,US Indoor temperature(°F) 72 72 Elevation: 271 ft Design TD(°F) 66 16 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 29.2 29.5 Dry bulb(°F) 6 88 Infiltration: Daily range(°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btuh/ft2 Btuh %of load Walls 6.4 11587 30.6 Ducts Glazing 37.6 10796 28.5 Doors 25.7 1619 4.3 Walls Ceilings 1.6 1740 4.6 Infiltration Floors 1.9 1231 3.2 Infiltration 4.2 8348 22.0 Ducts 2595 6.8 Piping 0 0 Floors Humidification 0 0 Ceilings Ventilation 0 0 / Doors Adjustments 0 Glazing Total 37917 100.0 Coolin• Component Btuh/ft2 Btuh %of load Walls 2.3 4187 16.3 Glazing 51.0 14657 57.2 Walls Internal Gains Doors 10.5 663 2.6 Ducts Infiltration Ceilings 1.2 1333 5.2 Other Floors 0.5 306 1.2 Ceilings Infiltration 0.6 1237 4.8 Doors Ducts 1117 4.4 Ventilation 0 0 Internal gains 2120 8.3 Blower 0 0 Adjustments 0 Glazing Total 25621 100.0 Latent Cooling Load=2522 Btuh Overall U-value=0.107 Btuh/ft2-°F, Window/FloorArea=14.4% Data entries checked. wrightsoft® 2023-JU-1912:18:24 A ..- ., --°-' Right-SUte®Universal 2023 23.0.01 RSU63755 Page 4 ..DesigrfMarual J[23-010-0233,Kyle Blocherl.np Calc=MJ8 Front Door faces:NE +I+ wrightsoft Load Short Form Jo Date: 23-010-0233 Entire House By: Dandelion Energy 333 North Bedford Road,Sate 220,Moult Kisco,NY 10549 Phone:833-GE0-4ALL Email:desigrtwdardelionenergy.com Web:www.dardelionenergy.com Project Information . For: Kyle Blocher 2 Shepherds Hollow Rd,Northampton,MA01062 Design Information Htg Clg Infiltration Outside db(°F) 6 88 Method Simplified Inside db(°F) 72 72 Construction quality Average Design TD(°F) 66 16 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/Ib) 29 30 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref. n/a Coil n/a AHRI ref. n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual airflow 0 drn Actual airflow 0 t,fni Air flow factor 0 cfrnBtuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load HtgAVF CIgAVF (ft2) (Btuh) (Btuh) (Lint) (cfrn) System 1 1997 37917 25621 1370 1370 (Unconditioned) 1250 0 0 0 0 Con by Other 504 10124 0 0 0 Entire House 3751 48041 25621 1370 1370 Other equip loads 0 0 Equip.@ 0.93 RSM 23930 Latent cooling 2522 TOTALS 3751 48041 26452 1370 1370 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 41- wrightsoft 2023-Ju-19 12:1824 >M.iwi• —,,,,,.. Right-Sute5 Universal 202323.0.01 RSU63755 Page 1 ACCA ...DesigriJ 1anual J[23-010-0233,Kyle Blocherl.rp Calc=MJ8 Fiord Door faces:NE Load Form Job: 23-010-0233 +I+ wrightsoft ShortDate: (Unconditioned) By: Dandelion Energy 333 North Bedford Road,Sute 220,Mount Kisco,NY 10549 Phone:833-GEO-4ALL Email:design@dandelionenergy.com Web:wwwdardelionerergy.com Project Information For: Kyle Blocher 2 Shepherds Hollow Rd,Northampton,MA01062 Design Information Htg Clg Infiltration Outside db(°F) 6 88 Method Simplified Inside db(°F) 72 72 Construction quality Average Design TD(°F) 66 16 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(grub) 29 30 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual airflow 0 ufri1 Actual airflow 0 c,frn Air flow factor 0 cfiri/Btuh Air flow factor 0 cfrn/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load HtgAVF CIgAVF (ft2) (Btuh) (Btuh) (c,lin) (cfrn) Garage 505 0 0 0 0 Mudroom 113 0 0 0 0 Utility 632 0 0 0 0 (Unconditioned) 1250 0 0 0 0 Other equip loads 0 0 Equip.@ 0.93 RSM 0 Latent cooling 0 TOTALS 1250 0 0 0 0 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. w rightsoft' 2023-JU-1912:18:24 . Rip-Suite®Urrversal202323.0.01 RSU63755 Paget ACCI\ ...DesigrdManual J[23-010-0233,Kyle Blocherls p Calc=MJ8 Front Door faces:NE +I+ wrightsoft Load Short Form Date: 23-010-0233 Con by Other By: Dandelion Energy 333 North Bedford Road,Sute 220,Mood Kisco,NY 10549 Phone:833-GE0-4ALL Email:design@dardelionenergy.com Web:www.dandelionenergy.com Project Information For: Kyle Blocher 2 Shepherds Hollow Rd,Northampton,MA01062 Design Information Htg Clg Infiltration Outside db(°F) 6 88 Method Simplified Inside db(°F) 72 72 Construction quality Average Design TD(°F) 66 16 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/Ib) 29 30 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual airflow 0 elm Actual airflow 0 cfrn Air flow factor 0 elrnBtuh Air flow factor 0 GI-TT/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load HtgAVF CIgAVF (ft°) (Btuh) (Btuh) Pin) (cfrn) Rec Room 504 10124 0 0 0 Con by Other 504 10124 0 0 0 Other equip loads 0 0 Equip.@ 0.93 RSM 0 Latent cooling 0 TOTALS 504 10124 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2023-Jr/-19 12,18.24 CA . . ...,, .,,. . Rigid-Su 9 te®Universal 2023 23.0.01 RSU63755 Page 3 AC ..Desigrn\Marual J[23-010-0233,Kyle Blocherinp Calc=MJ8 Frord Door faces:NE 9 Load Short Form Job: 23-010-0233 wrightsoft Date: System 1 By: Dandelion Energy 333 North Bedford Road,Site 220,Moult Kisco,NY 10549 Phone:833-GE0-4ALL Email:design@dardelionenergy.com Web:wwwdardelionenergy.com Project Information For: Kyle Blocher 2 Shepherds Hollow Rd,Northampton, MA01062 Design Information Htg Clg Infiltration Outside db(°F) 6 88 Method Simplified Inside db(°F) 72 72 Construction quality Average Design TD(°F) 66 16 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/Ib) 29 30 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model YT-048 Cond YT-048 AHRI ref Coil AHRI ref Efficiency 0 COP Efficiency 0 EER Heating input 0 kW Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual airflow 1370 Jrn Actual airflow 1370 Grin Air flow factor 0.036 c,frrl/Btuh Air flow factor 0.053 cfm/Btuh Static pressure 0.40 in H2O Static pressure 0.40 in H2O Space thermostat Load sensible heat ratio 0.91 Capacity balance point=0°F Backup: Input=0 kW, Output=0 Btuh, 100 AFUE ROOM NAME Area Htg load Clg load HtgAVF CIgAVF (ft2) (Btuh) (Btuh) (dm) (air') Family 253 5340 2950 193 158 Breakfast 126 3552 2664 128 142 Foyer 78 1730 888 62 47 Bath 1 62 0 0 0 0 Living 170 4542 2305 164 123 Hall 1 68 983 297 36 16 Dining 109 4198 3928 152 210 Kitchen 209 2813 3305 102 177 Bed 1 186 3647 2625 132 140 Bed 2 192 3112 1759 112 94 Bath 2 110 1860 1514 67 81 Bath 3 62 1018 527 37 28 Hall2 175 1455 491 53 26 Primary 198 3667 2370 132 127 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. +�- wrightsoft zoz3-Jul-191z 16:2a ,t, Riga-SiteeUriversal202323.0.01 RSU63755 Page 4 ACCP. ...DesigrffManual J 123-010-0233,Kyle Blodrer].rup Calc=MJ8 Front Door faces:NE System 1 1997 37917 25621 1370 1370 Other equip loads 0 0 Equip.@ 0.93 RSM 23930 Latent cooling 2522 TOTALS 1997 37917 26452 1370 1370 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2023-JU-19 12 1824 „'� ,,,, .h.,,.,,..h. h,,,,. Rigtt-Sute®Universal 2023 23.0.01 RSU63755 Page 5 ACCt ...Design\Manual J[23-010-0233,Kyle Blocher].riQ Calc=MJ8 Front Door faces:NE +I+ wrightsoft Right-J8® Form J1 Job: 23-010-0233 Entire House Date: By: Dandelion Energy 333 North Bedford Road,Sute 220,Mount Kisco,NY 10549 Phone:833-GEO-4ALL Email:design@dandelionenergy.com Web:www.dardelionenergy.com I1 I Name of Room Entire House System 1 2 Running Feet of Exposed Wall 533.1 ft 270.3 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SqFt) 8.0 ft 9330.7 ft' 8.0 ft 5943.7 ft" 41 Room Dimensions(Ft)and Floor Plan Area(SqFt) 3750.7 ft" 1997.3 ft 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SqFt) 0 ° 3750.7 ft' 0 ° 1997.3 ft' Type of Const, Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Ualll 12B-0sw ne 4.53 1.17 1030 3922 1011 568 2707 1011 Glaz 1D-c2ow ne 32.33 37.56 144 4639 5390 124 4639 5390 Door 11D0 ne 25.70 10.53 21 540 221 21 540 221 Wall 12B-0sN se 3.19 1.19 832 2138 798 354 2138 798 111 Glaz 1 D-c2ow se 32.55 47.00 23 732 1058 20 732 1058 1---Door 11D0 se 0.00 0.00 140 0 0 0 0 0 Wall 126-Osw sw 3.30 1.23 1018 2798 1045 556 2798 1045 Glaz 1 D-c2osd sw 37.56 54.23 42 1578 2278 42 1578 2278 -Glaz 1D-c2ow sw 33.59 48.50 85 2859 4129 76 2859 4129 Door 11D0 sw 0.00 0.00 42 0 0 0 0 0 Wall 12B Osw w 6.39 2.39 15 62 23 15 62 23 I-Glaz 1 D-c2ow w 37.56 61.92 6 208 343 6 208 343 (Wall 126-0sw nw 5.13 1.43 832 4042 1122 512 3006 1122 I-Glaz 1 D-c2ow nw 32.82 38.13 24 779 906 21 779 906 t Door 11D0 nw 25.70 10.53 21 540 221 21 540 221 Vi all 12B-osw - 6.39 0.36 538 3305 189 158 876 189 I Door 11D0 n 25.70 10.53 21 540 221 21 540 221 Wall 12B-Osw - 0.00 0.00 380 0 0 0 0 0 Ceil 16B-19ad - 0.32 0.00 685 218 0 0 0 0 Ceil 16B-50ad - 1.32 1.01 923 1217 932 923 1217 932 Ceil C part ceiling. - 3.46 2.65 151 523 401 151 523 401 Flor 19A-Obswp - 3.24 0.00 1136 3678 0 0 0 0 Ror 19A-Obswp - 0.07 0.02 623 42 10 6 42 10 Ror 19A-30bswp - 1.88 0.47 632 1189 296 632 1189 296 Infiltration Heating Load(Btuh) 0.41 9814 8348 Effect WAR WAR 12 Sensible Load(Btuh) ACH 1.00 1237 1.00 1237 0.26 Latent Load(Btuh) 1378 1378 Internal a I Occupants at 230 and 200 Btuh 4 920 800 4 920 800 13I cb D nultAdjuslments 1 1200 1200 d l Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 45363 24504 2178 35322 24504 2178 Dud EHLF&ESGF 0.089 0.046 2678 1117 2595 1117 15 Loads ELG 344 344 16 Ventilation Loads VentCfm 0 E Cfm 0 0 0 0 0 0 0 17 Winter Humidification Load Gal/Day 0 0 0 18 Piping Load 0 0 19 Blower Heat 0 0 20 AED Fmursion&Latent Moisture fvigration Load 554 554 21 Total Load Sum lines 13 through 19 48041 25621 2522 37917 25621 2522 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. - wrighisoV 2023-Jul-1912:18:24 "" ""-'-"'_^"--^ Right-Suite®Universal 202323.0.01 RSU63755 Page 1 ACCA DesigrtManual J[23-010-0233,Kyle Blochedstp Calc=MJ8 Front Door faces:NE - wrightsoft Right-J8® Form J1 Job: 23-010-0233 Entire House Date: By Dandelion Energy 333 North Bedford Road,Sate 220,Moult Kisco,NY 10549 Phone:833-GEO-4ALL Email:design@dandelionenergy.com Web:wwwdardelionenergy.com 1 Name of Room (Unconditioned) I Con by Other 2 Running Feet of Exposed Wall 171.3 ft 91.5 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SgFt) 8.0 ft 2275.0 ft' 8.0 ft 1112.0 fF 4 Room Dimensions(Ft)and Floor Plan Area(SgFt) 1249.8 118 503.7 ft 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SgFt) 0 ° 1249.8 ft' 0 ' 503.7 ft' Type of Const, Panel HTM Area or Btuh Area or BWh Exposure Number Faces Length - - Length Htg. Clg. Heating S-Cig L-Clg Heating S-Clg L-Clg 6 Wall 12B-Osw ne 4.53 1.17 272 0 0 190 1215 0 II Glaz 1D-c2ow ne 32.33 37.56 20 0 0 0 0 0 Door 11D0 ne 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osw se 3.19 1.19 478 0 0 0 1 0 0 11 Glaz 1D-c2ow se 32.55 47.00 3 0 0 0 0 0 Door 11D0 se 0.00 0.00 140 0 0 0 0 0 Wall 12B-Osw sw 3.30 1.23 462 0 0 0 0 0 Glaz 1 D-c2osd sw 37.56 54.23 0 0 0 0 0 0 -Glaz 1D-c2ow sw 33.59 48.50 9 0 0 0 0 0 Door 11D0 sw 0.00 0.00 42 0 0 0 0 0 Wall 12B Osw w 6.39 2.39 0 0 0 0 0 0 laz 1D-c2ow w 37.56 61.92 0 0 0 0 0 0 Wall 12B-Osw nw 5.13 1.43 158 0 0 162 1036 0 -Glaz 1D-c2ow nw 32.82 38.13 3 0 0 0 0 0 Door 11D0 nw 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osw - 6.39 0.36 0 0 0 380 2429 0 Door 11D0 n 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osw - 0.00 0.00 380 0 0 0 0 0 Ceil 16B-19ad - 0.32 0.00 617 0 0 68 218 0 Cell 1613-50ad - 1.32 1.01 0 0 0 0 0 0 Ceil C part ceiling, - 3.46 2.65 0 0 0 0 0 0 Flor 19A-Obsnp - 3.24 0.00 632 0 0 504 3678 0 for 19A-Obsnp - 0.07 0.02 617 0 0 0 0 0 for 19A-30bswp - 1.88 0.47 0 0 0 0 0 0 Infiltration Heating Load(Btuh) 0.41 0 1466 Effed WAR WAR 12 Sensible Load(Btuh) ACH 1.00 0 1.00 0 - 0.26 Latent Load(Btuh) 0 0 Internal a I Ooaipants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 0 13 c Default Adjustments de Plan I Customts Appliances 0 0 0 0 0 0 14 Subtotals Sum lines 6 through 12 0 0 0 10041 0 0 Dud EHLF&ESGF 0.008 0 0 0 83 0 15 Loads ELG 0 0 16 Ventilation Loads VentCfm 0 E Cim 0 0 0 0 0 0 0 17 Wnter Humidification Load Gal/Day 0 0 0 18 Piping Load 0 0 19 Blower Heat 0 0 20 AED Excursion&Latent Moisture Migration Load 0 0 21 Total Load Sum lines 13 through 19 0 0 0 10124 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -41- wrlghtsoTt' 2023-Ja-1912:18:24 Right-Sut3e®Uriversal 2023 23.0.01 RSU63755 Page 2 ��p' ...DesigrfManual J[23-010-0233,Kyle Blocherj.rup Calc=MJ8 Front Door faces:NE 4 wrightsoft Right-J8® Form J1 Job: 23-010-0233 (Unconditioned) Date: By: Dandelion Energy 333 North Bedford Road,Sute 220,Moult Kisco,NY 10549 Phone:833-GEO-4ALL Email design@dardelionenergy.com Web:wwwdardelionenergy.com 1 Name of Room (Unconditioned) I Garage 2 Running Feet of Exposed Wall 171.3 ft 62.3 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SgFt) 8.0 ft 2275.0 ft' 8.0 ft 800.0 ft' 4 Room Dimensions(Ft)and Floor Plan Area(SgFt) 1249.8 ft' 1.0 x 504.9 ft 504.9 ft' 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SgFt) 0 ° 1249.8 ft' 0 ° 504.9 ft' Type of Const, • Panel HTM Area or Btuh Area or Btuh Fxpasi,re Number Faces Length - - Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 all 12B-Osni ne 0.00 0.00 272 0 0 178 0 0 laz 1D-c2ow ne 0.00 0.00 20 0 0 20 0 0 Door 11D0 ne 0.00 0.00 0 0 0 0 0 0 Wall 12B-0sa se 0.00 0.00 478 0 0 222 0 0 11 I Glaz 1D-c2ow se 0.00 0.00 3 0 0 0 0 0 Door 11D0 se 0.00 0.00 140 0 0 140 0 0 Wall 12B-0sw sw 0.00 0.00 462 ' 0 0 34 0 0 I Glaz 1 D-c2ovd sw 0.00 0.00 0 0 0 0 0 0 -Glaz 1D-c2ow sw 0.00 0.00 9 0 0 6 0 0 Door 11D0 sw 0.00 0.00 42 0 0 0 0 0 Wall 12B-Osw w 0.00 0.00 0 0 0 0 0 0 I Glaz 1D-c2ow w 0.00 0.00 0 0 0 0 0 0 Wall 12B-0sw nw 0.00 0.00 158 0 0 64 0 0 -Glaz 1D-c2ow nw 0.00 0.00 3 0 0 0 0 0 Door 11D0 nw 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw - 0.00 0.00 0 0 0 0 0 0 Door 11D0 n 0.00 0.00 0 0 0 0 0 0 Wall 12B-0sw - 0.00 0.00 380 0 0 0 0 0 Cell 16B-19ad - 0.00 0.00 617 0 0 505 0 0 Cell 16B-50ad - 0.00 0.00 0 0 0 0 0 0 Ceil C part ceiling - 0.00 0.00 0 0 0 0 0 0 for 19A-Obsnp - 0.00 0.00 632 0 0 0 0 0 for 19A-obsvvp - 0.00 0.00 617 0 0 505 0 0 Flor 19A-30bswp - 0.00 0.00 0 0 0 0 0 0 I Infiltration Heating Load(Btuh) 0 0 0 Effed WAR WAR 12 Sens ble Load(Btuh) ACH 1.00 0 0 0 0 Latent Load(Btuh) 0 Internal a I Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 I I 0 13 c DefaultAdjusirnents de I Custo Appliances 0 0 0 0 Plants m 0 0 14 Subtotals Sum lines6 through 12 0 0 0 0 0 Dud EHLF&ESGF 0 0 0 0 0 0 15 Loads ELG 0 0 16 Ventilation Loads Vent Cfm 0 E Cfm 0 0 0 0 17 Winter Humidification Load Gal/Day 0 0 18 Piping Load 0 19 Blower Heat 0 20 AED Excursion&Latent Moisture Migration Load 0 0 21 Total Load Sum lines 13 through 19 0 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ -Pk- w rlgFatsoft" 2023-Jr1-1912:18:24 ACCA °"" Y Right-Suite®Universal 2023 23.0.01 RSU63755 Page 3 ...DesigrtMar>tel J[23-010-0233,Kyle Blocherl.nto Calc=MJ8 Frori Door faces:NE 4 wrightsoft Right-J8® Form J1 Job: 23-010-0233 (Unconditioned) Date: By: Dandelion Energy 333 North Bedford Road,Sute 220,Moult Kisco,NY 10549 Phone:833-GE0-4ALL Email:design@dardelionenergy.com Web:wwwdardelionenergy.com 1 Name of Room I Mudroom I Utility 2 Running Feet of Exposed Wall 18.0 ft 91.0 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SgFt) 8.0 ft 367.0 ft 8.0 ft 1108.0 ftW 4 Room Dimensions(Ft)and Floor Plan Area(SgFt) 18.0 x 6.3 ft 112.5 If 1.0 x 632.3 ft 632.3 If 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SgFt) 0 ' 112.5 If 0 ° 632.3 fF Type of Const, Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length - --- Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 12B-0sw ne 0.00 0.00 0 0 0 94 0 0 Glaz 1D-c2ow ne 0.00 0.00 0 0 0 0 0 0 Door 11D0 ne 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw se 0.00 0.00 0 0 0 256 0 0 11 [ Glaz 1 D-c2ow se 0.00 0.00 0 0 0 3 0 0 I Door 11D0 se 0.00 0.00 0 0 0 0 0 0 Wall 12B-0sw sw 0.00 0.00 144 0 0 284 0 0 Glaz 1 D-c2osd sw 0.00 0.00 0 0 0 0 0 0 -Glaz 1 D-c2ow sw 0.00 0.00 0 0 0 3 0 0 Door 11D0 sw 0.00 0.00 21 0 0 21 0 0 Wall 12B-osw w 0.00 0.00 0 0 0 0 0 0 L Glaz 1D-c2ow w 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw nw 0.00 0.00 0 0 0 94 0 0 I GIaz 1 D-c2ow nw 0.00 0.00 0 0 0 3 0 0 Door 11D0 nw 0.00 0.00 0 0 0 0 0 0 Wall 12B-0sv - 0.00 0.00 0 0 0 0 0 0 I-Door 11D0 n 0.00 0.00 0 0 0 0 0 0 Wall 12B-0m - 0.00 0.00 0 0 0 380 0 0 Cell 16B-19ad - 0.00 0.00 113 0 0 0 0 0 Cell 168-50ad - 0.00 0.00 0 0 0 0 0 0 Ceil C part ceiling. - 0.00 0.00 0 0 0 0 0 0 Ror 19A-Obswp - 0.00 0.00 0 0 0 632 0 0 Ror 19A-0bswp - 0.00 0.00 113 0 0 0 0 0 Ror 19A-30bswp - 0.00 0.00 0 0 0 0 0 0 Infiltration Heating Load(Btuh) 0 0 0 Effed WAR WAR 12 Sensible Load(Btuh) ACH 0 0 0 0 - 0 Latent Load(Btuh) Internal a I Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b• Scenario number I 0 I 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines6 through 12 0 0 0 0 Dud EHLF&ESGF 0 0 0 0 0 0 15 Loads ELG 0 0 16 Ventilation Loads Vent Cfm 0 E Cfm 0 17 Winter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion&Latent Moisture Mgration Load 0 0 21 Total Load Sum lines 13 through 19 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrigFr.tsoR• 2023-Ju-1912.18.24 . "'-" Right-Sole®Universal 2023 23.0.01 RSU63755 Page 4�-EA ...DesigrfManual J[23-010-0233,Kyle Blocher].n.p Calc=MJ8 Front Door faces:NE + wrightsoft Right-J8® Form J1 Job: 23-010-0233 Con by Other Date: By Dandelion Energy 333 North Bedford Road,Sute 220,Moult Kisco,NY 10549 Phone:833-GEO-4ALL Email:design@dardelionenergy.com Web:wwwdandelionenergy.com 1 Name of Room I Con by Other I Rec Room 2 Running Feet of Exposed Wall 91.5 ft 91.5 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SqFt) 8.0 ft 1112.0 ft' 8.0 ft 1112.0 ft' 4 Room Dimensions(Ft)and Floor Plan Area(SqFt) 503.7 ft' 1.0 x 503.7 ft 503.7 fP 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SqFt) 0 ° 503.7 ft' 0 ° 503.7 It' Type of Const. Panel HTM Area or Btuh Area or Btuh Exposure Number Faces - Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 IWall - 12B-0sw ne 6.39 0.00 190 1215 0 190 1215 0 laz 1D-c2ow ne 0.00 0.00 0 0 0 0 0 0 . Door 11D0 ne 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw se 0.00 0.00 0 0 0 0 0 0 11 1 Glaz 1D-c2ow se 0.00 0.00 0 0 0 0 0 0 Door 11 D0 se 0.00 0.00 0 0 0 0 0 0 Wall 12B-osv sw 0.00 0.00 0 0 0 0 0 0 Glaz 1 D-r2ovd sw 0.00 0.00 0 0 0 0 0 0 Glaz 1D-c2ow sw 0.00 0.00 0 0 0 0 0 0 Door 11 D0 sw 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw w 0.00 0.00 0 0 0 0 0 0 I Glaz 1D-c2ow w 0.00 0.00 0 0 0 0 0 0 Wall 12B-0s, nw 6.39 0.00 162 1036 0 162 1036 0 l Glaz 1D-c2ow nw 0.00 0.00 0 0 0 0 0 0 I-Door 11 DO nw 0.00 0.00 0 0 0 0 0 0 Wall 12B-0sw - 6.39 0.00 380 2429 0 380 2429 0 Door 11 D0 n 0.00 0.00 0 0 0 0 0 0 Wall 12B-0sw - 0.00 0.00 0 0 0 0 0 0 Ceil 16B-19ad - 3.23 0.00 68 218 0 68 218 0 Ceil 16B-50ad - 0.00 0.00 0 0 0 0 0 0 Ceil C part ceiling. - 0.00 0.00 0 0 0 0 0 0 Flor 19A-0bsvnp - 7.30 0.00 504 3678 0 504 3678 0 Flor 19A-Obswp - 0.00 0.00 0 0 0 0 0 0 Flor 19A-30bswp - 0.00 0.00 0 0 0 0 0 0 Infiltration Heating Load(Btuh) 0.30 1466 1466 Effect WAR WAR 12 Sensible Load(Btuh) ACH 1.00 0 1.00 0 0 Latent Load(Btuh) 0 Internal a I Dw pants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 II 0 13 c Default Adjustments de I CPlanustomts Appliances 0 0 0 0 0 0 14 Subtotals Sum lines6 through 12 10041 0 0 10041 0 Dud EHLF&ESGF 0.008 0 83 0 83 0 15 Loads ELG 0 0 16 Ventilation Loads Vent Cfm 0 E Cfm 0 0 0 0 17 Wnter Humidification Load Gal/Day 0 0 18 Piping Load 0 19 Blower Heat 0 20 AED Excursion&Latent Moisture Migration Load 0 0 21 Total Load Sum lines 13 through 19 10124 0 0 10124' 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -1 wrlgF0tsoft- 2023-Ju-1912:18:24 ---''""""""".--'-'"''- Right-Sute®Universal 202323.0.01 RSU63755 Page 5 .4C�1. ...DesigrtManal J]23-010-0233,Kyle Blocher-trap Calc=MJ8 Front Door faces:NE +I+ wrightsoft Right-J8® Form J1 Job: 23-010-0233 System 1 Date: By: Dandelion Energy 333 North Bedford Road,Sute 220,Mount Kisco,NY 10549 Phone:833-GEO-4ALL Email:design@dandelionenergy.com Web:www.dandelionenergy.com 1 Name of Room System 1 Family 2 Running Feet of Exposed Wall 270.3 ft 38.8 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SgFt) 8.0 ft 5943.7 ft' 8.0 ft 524.0 IF 4 Room Dimensions(Ft)and Floor Plan Area(SgFt) 1997.3 tf 12.5 x 20.3 ft 253.1 fF 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SgFt) 0 ° 1997.3 f 0 ° 253.1 IF Type of Const, Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 IWall 12B-0sv ne 6.39 2.39 568 2707 1011 100 428 160 Claz 1D-c2ow ne 37.56 43.64 124 4639 5390 33 1240 1440 Door 11D0 ne 25.70 10.53 21 540 221 0 0 0 Wall 12B-0sv se 6.39 2.39 354 2138 798 48 307 115 1 1 IGlaz 1 D-c2ow se 37.56 54.23 20 732 1058 0 0 0 Door 11D0 se 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw sw 6.39 2.39 556 2798 1045 0 0 0 Glaz 1 D-c2ovd sv 37.56 54.23 42 1578 2278 0 0 0 -Glaz 1 D-c2ow sw 37.56 54.23 76 2859 4129 0 0 0 Door 11D0 sw 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw w 6.39 2.39 15 62 23 0 0 0 1-Glaz 1 D-c2ow w 37.56 61.92 6 208 343 0 0 0 Wall 12B-Osw nw 6.39 2.39 512 3006 1122 162 825 308 l Glaz 1 D-c2ow nw 37.56 43.64 21 779 906 12 451 524 L-Door 11D0 nw 25.70 10.53 21 540 221 21 540 221 Wall 12B-Osv - 6.39 1.38 158 876 189 0 0 0 1-Door 11D0 n 25.70 10.53 21 540 221 0 0 0 Wall 12B-Osw - 0.00 0.00 0 0 0 0 0 0 Cell 16B-19ad - 0.00 0.00 0 0 0 0 0 0 Ceil 16B-50ad - 1.32 1.01 923 1217 932 0 0 0 Ceil C part ceiling. - 3.46 2.65 151 523 401 75 259 199 Flor 19A-Obswp - 0.00 0.00 0 0 0 0 0 ( 0 Flor 19A-0bswp - 7.30 1.82 6 42 10 0 0 0 For 19A-30bswp - 1.88 0.47 632 1189 296 0 0 0 Infiltration Heating Load(Btuh) 0.44 8348 1291 Effect WAR WAR ' 12 Sensible Load(Btuh) ACH 1.00 1237 0.15 191 - 0.26 Latent Load(Btuh) 1378 Internal a I Coal pants at 230 and 200 Btuh 4 920 800 0 0 0 b Scenario number I 1200 I 0 13 c Default Adjustments del CusPltomants Appliances 0 0 0 0 0 0 14 Subtotals Sum lines 6 through 12 35322 24504 2178 5340 2950 Duct EHLF&ESGF 0.073 0.046 2595 1117 0 0 15 Loads ELG 344 0 16 Ventilation Loads Vent Cfm 0 E Cfm 0 0 0 0 17 Winter Humidification Load Gal/Day 0 0 18 Piping Load 0 19 Blower Heat 0 20 AED Excursion&Latent Moisture Mgration Load 554 -207 21 Total Load Sum lines 13 through 19 37917 25621 2522 5340 2950 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -'-F wrlghtsoft" 2023-Ju-1912:18:24 Right-Suite®Universal 2023 23.0.01 RSU63755 Page 6 ACCA ...DesigrtMan al J[23-010-0233,Kyle Blocher-].hp Calc=MJ8 Front Door faces:NE 4 wrightsoft Right-J8® Form J1 Job: 23-010-0233 System 1 Date: By: Dandelion Energy 333 North Bedford Road,Sute 220,Moult Kisco,NY 10549 Phone:833-GE0-4ALL Email:design@darxtelionenergy.com Web:wwwdandelionenergy.com 1 Name of Room I Breakfast Foyer 2 Running Feet of Exposed Wall 22.3 ft 11.3 ft 3 Ceiling Ht(Ft)and Gross WallArea(SgFt) 8.0 ft 354.7 ft' 8.0 ft 408.0 ft 4 I Room Dimensions(Ft)and Floor Plan Area(SgFt) 1.0 x 126.2 ft 126.2 ft 1.0 x 77.8 ft 77.8 ft' 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SgFt) 0 ° 126.2 ft' 0 ° 77.8 ft' Type of Const, I Panel HTM Area or Btuh Area or Btuh Fxpcxiue Number Faces Length Length Htg. Clg. Healing S-Clg L-Clg Heating S-Cig L-Clg 6 Wall 12B-Osw ne 6.39 2.39 0 0 0 90 364 136 . -Glaz 1D-c2ow ne 37.56 43.64 0 0 0 12 451 524 Door 11D0 ne 25.70 10.53 0 0 0 21 540 221 Wall 12B-Osw se 6.39 2.39 0 0 0 0 0 0 11 I Glaz 1D-c2ow se 37.56 54.23 0 0 0 0 0 0 Door 11 D0 se 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw sw 6.39 2.39 70 318 119 0 0 0 Glaz 1 D-c2ovd sw 37.56 54.23 0 0 0 0 0 0 -Glaz 1D-c2ow sw 37.56 54.23 20 756 1091 0 0 0 Door 1100 sw 0.00 0.00 0 0 0 0 0 0 (Wall 12B-Osw w 6.39 2.39 15 62 23 0 0 0 I Glaz 1D-c2ow w 37.56 61.92 6 208 343 0 0 0 Wall 12B-0sw nw 6.39 2.39 94 601 224 0 0 0 -Glaz 1D-c2ow nw 37.56 43.64 0 0 0 0 0 0 I Door 11 D0 nw 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osv - 6.39 1.38 0 0 0 0 0 0 Door 11 D0 n 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osw - 0.00 0.00 • 0 0 0 0 0 0 Ceil 16B-19ad - 0.00 0.00 0 0 0 0 0 0 Cell 16B-50ad - 1.32 1.01 0 0 0 0 0 0 Cell C part ceiling, - 3.46 2.65 6 20 15 0 0 0 Flor 19A-Obsnp - 0.00 0.00 0 0 0 0 0 0 Flor 19A-Obsnp - 7.30 1.82 6 42 10 0 0 0 Flor 19A-30bswp - 1.88 0.47 120 226 56 0 0 0 Infiltration Heating Load(Btuh) 0.44 746 375 Effect WAR WAR 12 Sensible Load(Btuh) ACH 0.09 111 0.04 56 - 0.26 . Latent Load(Btuh) Internal a I Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 0 13 c Default Adjustments de Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 2979 2426 1730 888 Dud EHLF&ESGF 0.073 0.046 573 238 0 0 15 Loads ELG 64 0 16 Ventilation Loads Vent Cfm 0 E Ctm 0 • 17 Winter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion&Latent Moisture Migration Load 432 -49 21 Total Load Sum lines 13 through 19 3552 2664 1730 888 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. L vi.r 9 t soRW 2023-Ju-1912:18.24e 7 .A�A ..Deli rlManual J[23-010.0233 Riga Sute®U tiversal 2023 23.0.01 RSU63755 Pa g ,Kyle Blocherj.r Calc=MJ8 Front Door faces:NE 9 +I+ wrightsoft Right-J8® Form J1 Job: 23-010-0233 System 1 Date: By Dandelion Energy 333 North Bedford Road,Sute 220,Moult Kisco,NY 10549 Plane:833-GEO-4ALL Email:design@dandelionenergy.com Web:wwwdandelionenergy.com 1 Name of Room I Bath 1 Living I 2 Running Feet of Exposed Wall 0 ft 32.3 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SgFt) 8.0 ft 252.0 ft' 8.0 ft 536.0 f 4 Room Dimensions(Ft)and Floor Plan Area(SqFt) 8.3 x7.5 ft 61.9 fF 11.8 x 14.5 ft 170.4 ft' 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SgFt) 0 ° 61.9 ft' 0 ° 170.4 ft Type of Const, Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 all 12B-Osw ne 6.39 2.39 0 0 0 94 390 146 laz 1D-c2ow ne 37.56 43.64 0 0 0 33 1240 1440 Door 11D0 ne 25.70 10.53 0 0 0 0 0 0 Tall 12B-Osw se 6.39 2.39 0 0 0 0 0 0 11 Glaz 1D-c2ow se 37.56 54.23 0 0 0 0 0 0 Door 11D0 se 0.00 0.00 0 0 0 0 0 0 Wall 12B-09,v ss 6.39 2.39 0 0 0 0 0 0 Dlaz 1 D-c2ovd sw 37.56 54.23 0 0 0 0 0 0 laz 1D-c2ow sw 37.56 54.23 0 0 0 0 0 0 Door 11D0 sw 0.00 0.00 0 0 0 0 0 0 all 12B-Osw w 6.39 2.39 0 0 0 0 0 0 laz 1D-c2ow w 37.56 61.92 0 0 0 0 0 0 Wall 12B-Osw nw 6.39 2.39 0 0 0 48 307 115 -Glaz 1D-c2ow nw 37.56 43.64 0 0 0 0 0 0 Door 1100 nw 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osw - 6.39 1.38 0 0 0 116 742 160 Door 11DO n 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osw - 0.00 0.00 0 0 0 0 0 0 Ceil 16B-19ad - 0.00 0.00 0 0 0 0 0 0 Ceil 168-50ad - 1.32 1.01 0 0 0 0 0 0 Ceil C part ceiling. - 3.46 2.65 0 0 0 71 244 187 Flor 19A-0bswp - 0.00 0.00 0 0 0 0 0 0 , Hor 19A-Obssp - 7.30 1.82 0 0 0 0 0 0 Ror 19A-30bswp - 1.88 0.47 0 0 0 158 297 74 Infiltration Heating Load(Btuh) 0.44 0 591 Effect WAR WAR 12 Sensible Load(Btuh) ACH 0 0 0.07 88 0 26 Latent Load(Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 0 0 3809 2099 Dud EHLF&ESGF 0.073 0.046 0 0 733 206 15 Loads ELG 0 86 16 Ventilation Loads Vent Cfm 0 E Cfm 0 17 Wnter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion&Latent Moisture Migration Load 0 -110 21 Total Load Sum lines 13 through 19 0 0 4542 2305 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightscw t' 2023-J4-1912:1824 """ "" ---"' ' Right-Sate®Uriversal 2023 23.0.01 RS1J63755 AC f. Page 8 ...DesigrfVNlanual J[23-010-0233,Kyle Blocheri.rup Calc=MJ8 Front Door faces:NE +3# wrightsoft Right-J8® Form J1 Job: 23-010-0233 System 1 Date: By: Dandelion Energy 333 North Bedford Road,Stile 220,Moult Kisco,NY 10549 Phone:833-GE0-4ALL Email:design@dandelionenergy.com Web:wwwdandelionenergy.com 1 Name of Room I Hall 1 I Dining 2 Running Feet of Exposed Wall 5.8 ft 21.0 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SgFt) 1 8.0 ft 301.0 ft' 8.0 ft 336.0 ft' 4 Room Dimensions(Ft)and Floor Plan Area(SgFt) 11.8 x 5.8 ft 67.6 ft' 9.3 x 11.8 ft 108.7 ft' 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SgFt) 0 ° 67.6 1t' 0 ° 108.7 ft' Type of Const, Panel HTM Area or Btuh Area or Btuh Expo,Aire Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 12B-0sw ne 6.39 2.39 0 0 0 0 0 0 �laz 1D-c2ow ne 37.56 43.64 0 0 0 0 0 0 Door 11D0 ne 25.70 10.53 0 0 0 0 0 0 . Wall 12B-0sw se 6.39 2.39 4 26 10 94 553 206 11 I Glaz 1D-c2ow se 37.56 54.23 0 0 0 8 282 407 Door 1100 se 0.00 0.00 0 0 0 0 0 0 Wall 12B-0sw sw 6.39 2.39 0 0 0 74 205 76 Glaz 1 D-c2ovd sw 37.56 54.23 0 0 0 42 1578 2278 -Glaz 1D-c2ow sw 37.56 54.23 0 0 0 0 0 0 Door 11D0 sw 0.00 0.00 0 0 0 0 0 0 Wall 12B-0sw w 6.39 2.39 0 0 0 0 0 0 L-Glaz 1D-c2ow w 37.56 61.92 0 0 0 0 0 0 (Wall 12B-0sw nw 6.39 2.39 0 0 0 0 0 0 I-Glaz 1D-c2ow nw 37.56 43.64 0 0 0 0 0 0 Door 11DO nw 25.70 10.53 0 0 0 0 0 0 VW/all 12B-0sw - 6.39 1.38 42 134 29 0 0 0 II Door 11D0 n 25.70 10.53 21 540 221 0 0 0 Wall 12B-0sw - 0.00 0.00 0 0 0 0 0 0 Ceil 16B-19ad - 0.00 0.00 0 0 0 0 0 0 Ceil 16B-50ad - 1.32 1.01 0 0 0 0 0 0 Ceil C part ceiling.. - 3.46 2.65 0 0 0 0 0 0 Nor 19A-Obsnp - 0.00 0.00 0 0 0 0 0 0 Nor 19A-0bsnp - 7.30 1.82 0 0 I 0 0 0 I 0 Nor 19A-30bsap - 1.88 0.47 58 108 27 109 204 51 Infiltration Heating Load(Btuh) 0.44 17 699 Effect WAR WAR 12 Sensible Load(Btuh) ACH 0.00 2 0.08 104 0.26 Latent Load(Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number O I I 0 13 c DefaultAdjusiments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines through 12 824 270 3521 3577 Duct EHLF&ESGF 0.073 0.046 159 27 677 351 15 Loads ELG 34 55 16 Ventilation Loads Vent Cfm 0 E Cfm 0 17 Winter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion&Latent Moisture Migration Load -19 455 21 Total Load Sum lines 13 through 19 983 297 4198 3928 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ wrigMtsort• 2023-Jr1-1912:18:24 A1 . ' ---" Riga-Sute®Universal 202323.0.01 RSU63755 Page 9 � g anal J[23-010-0233,Kyle Blocher].ryu Calc=MJ8 Front Door faces NE * wrightsoft Right-J8® Form J1 Job: 23-010-0233 System 1 Date: By: Dandelion Energy 333 North Bedford Road,Sute 220,Mout Kisco,NY 10549 Phone:833-GEO-4ALL Email:design@dardelionenergy.com Web:vww.dandelionenergy.com I1 I Name of Room Kitchen I Bed 1 2 Running Feet of Exposed Wall 16.0 ft 28.8 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SqFt) 8.0 ft 484.0 ft' 8.0 ft 460.0 ft' 4 Room Dimensions(Ft)and Floor Plan Area(SqFt) 1.0 x 208.6 ft 208.6 ft' 1.0 x 186.3 ft 186.3 If 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SqFt) 0 ° 208.6 ft' 0 ° 186.3 ft' Type of Const. Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Healing S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 12B-Osw ne 6.39 2.39 0 0 0 0 0 0 . Glaz 1D-c2ow ne 37.56 43.64 0 0 0 0 0 0 Door 11D0 ne 25.70 10.53 0 0 0 0 0 0 . Wall 12B-Osw se 6.39 2.39 0 0 0 112 639 239 11 I Glaz 1 D-c2ow se 37.56 54.23 0 0 0 12 451 651 Door 11D0 se 0.00 0.00 0 0 0 0 0 0 Wall 12B-0sw sw 6.39 2.39 128 684 255 118 631 236 Glaz 1 D-c2ovd sw 37.56 54.23 0 0 0 0 0 0 -Glaz 1D-c2aw sw 37.56 54.23 21 789 1139 19 723 1044 Door 11D0 sw 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw w 6.39 2.39 0 0 0 0 0 0 I-Glaz 1 D-c2ow w 37.56 61.92 0 0 0 0 0 0 Wall 12B-Osw nw 6.39 2.39 0 0 0 0 0 0 -Glaz 1 D-c2ow nw 37.56 43.64 0 0 0 0 0 0 I-Door 11D0 nw 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osw - 6.39 1.38 0 0 0 0 0 0 Door '11D0 n 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osw - 0.00 0.00 0 0 0 0 0 0 Ceil 16B-19ad - 0.00 0.00 0 0 0 0 0 0 Ceil 166-50ad - 1.32 1.01 0 0 0 186 245 188 Ceil C part ceiling. - 3.46 2.65 0 0 0 0 0 0 Nor 19A-Obsnp - 0.00 0.00 0 0 0 0 0 0 Nor 19A-Obswp - 7.30 1.82 0 0 0 0 0 0 Flor 19A-30bstip - 1.88 0.47 188 354 88 0 0 0 Infiltration Healing Load(Btuh) 0.44 533 958 Effect WAR WAR 12 Sensible Load(Btuh) ACH 0.06 79 0.11 142 0.26 Latent Load(Btuh) Internal a I Ocaipants at 230 and 200 Btuh 0 0 0 1 230 200 b Scenario number 1200 0 13 c Default Adjustments de l CPlanustomts Appliances 0 0 0 0 0 0 14 Subtotals Sum lines6 through 12 2359 3009 3647 2625 Duct EHLF&ESGF 0.073 0.046 454 295 0 0 15 Loads ELG 105 0 16 Ventilation Loads Vent Cfm 0 E Cfrn 0 17 Winter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion&Latent Moisture Migration Load 248 -104 21 Total Load Sum lines 13 through 19 2813 3305 3647 2625 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 9 F�tsoR• 2023-Ju-19 12:18:24 ...Des ` I J- "- -"'•"'- Right-Suite®llriversal 2023 23.0.01 RSU63755 Page 10 g [23-010-0233,Kyle Blocher-lap Calc=MJ8 Front Door faces:NE +++ wrightsoft Right-J8® Form J1 Job: 23-010-0233 System 1 Date: By: Dandelion Energy 333 North Bedford Road,Suite 220,Mowt Kisco,NY 10549 Phone:833-GEO-4ALL Email:design@dardelioner ergy.com Web:wwwdardelionenergy.com 1 Name of Room Bed 2 I Bath 2 2 Running Feet of Exposed Wall 26.8 ft 14.5 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SqFt) 8.0 ft 464.0 ft' 8.0 ft 364.0 fP 4 Room Dimensions(Ft)and Floor Plan Area(SqFt) 1.0 x 191.6 ft 191.6 ft' 1.0 x 109.9 ft 109.9 ft' 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SqFt) 0 ° 191.6 ft' 0 ° 109.9 ft' Type of Const, Panel HTM Area or Btuh Area or Btuh Fxp ssure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 aM II 12B-osw ne 6.39 2.39 118 631 236 0 0 0 laz 1D-c2ow ne 37.56 43.64 19 723 840 0 0 0 . Door 11D0 ne 25.70 10.53 0 0 0 0 0 0 Wall 12B-osw se 6.39 2.39 96 614 229 0 0 0 1 1 Glaz 1D-c2ow se 37.56 54.23 0 0 0 0 0 0 Door 11D0 se 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw sty 6.39 2.39 0 0 0 116 641 239 -Glaz 1D-c2ovd sw 37.56 54.23 0 0 0 0 0 0 -Glaz 1D-c2ow sw 37.56 54.23 0 0 0 16 592 854 Door 11D0 Sw 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw w 6.39 2.39 0 0 0 0 0 0 Wall 1D-c2ow w 37.56 61.92 0 0 0 0 0 0 Wall 12B-0sw nw 6.39 2.39 0 0 0 0 0 0 -Glaz 1D-c2ow nw 37.56 43.64 0 0 0 0 0 0 I.--Door 11D0 nw 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osw - 6.39 1.38 0 0 0 0 0 0 Door 11D0 n 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osw - 0.00 0.00 0 0 0 0 ' 0 0 Ceil 16B-19ad - 0.00 0.00 0 0 0 0 0 0 Cell 168-50ad • - 1.32 1.01 192 253 194 110 145 111 Ceil C part ceiling. - 3.46 2.65 0 0 0 0 0 0 For 19A-Obsnp - 0.00 0.00 0 0 0 0 0 0 For 19A-Obsnp - 7.30 1.82 0 0 0 0 0 0 For 19A-30bswp - 1.88 0.47 0 0 0 0 0 0 Infiltration Heating Load(Btuh) 0.44 891 483 Effect WAR WAR 12 Sensible Load(Btuh) ACH 0.11 132 0.06 72 0.26 Latent Load(Btuh) Internal a Ooojpants at 230 and 200 Btuh 1 230 200 0 0 0 13 1 b Scenario number 0 0 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 3112 1759 1860 1514 Dud EHLF&ESGF 0.073 0.046 0 0 0 0 15 Loads ELG 0 0 16 Ventilation Loads VentCfm 0 E Cfm 0 17 Winter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion&Latent Moisture MSgration Load -102 238 21 Total Load Sum lines 13 through 19 3112 1759 1860 1514 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ soft 2023-J11-1912:18:24 ACCA ..Deli rNvlanalJ 2t010-0 Right-Sute®Unversal202323.0.01 RSU63755 Page 11 g [ 3- 233,Kyle Blocher].np Cale=MJ8 Front Door faces:NE +1+ wrightsoft Right-J8® Form J1 Job: 23-010-0233 System 1 Date: By Dandelion Energy 333 North Bedford Road,Sute 220,Moue Kisco,NY 10549 Phone:833-GEO-4ALL Email:design@dardelionenergy.com Web:www.dandelionenergy.com 1 Name of Room I Bath3 I Hall 2 Running Feet of Exposed Wall 8.5 ft 14.5 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SgFt) 8.0 ft 276.0 ft' 8.0 ft 704.0 ft' 4 Room Dimensions(Ft)and Floor Plan Area(SgFt) 1.0 x 62.1 ft 62.1 ft' 1.0 x 175.2 ft 175.2 ft" 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SgFt) 0 ° 62.1 ft' 0 ' 175.2 ft' Type of Const, Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length - - Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 IWall - 12B-Osw ne 6.39 2.39 68 390 146 0 0 0 H-Ulaz 1D-c2ow ne 37.56 43.64 7 263 306 0 0 0 Door 11 DO ne 25.70 10.53 0 0 0 0 0 0 Wall 12B-osw se 6.39 2.39 0 0 0 0 0 0 11 I Glaz 1D-c2ow se 37.56 54.23 0 0 0 0 0 0 Door 11 DO se 0.00 0.00 0 0 0 0 0 0 Wall 12B-0sw sw 6.39 2.39 0 0 0 50 320 119 Glaz 1 D-c2osd sw 37.56 54.23 0 0 0 0 0 0 -Glaz 1D-c2ow sw I 37.56 54.23 0 0 0 0 0 0 Door 11 DO sw 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw w 6.39 2.39 0 0 0 0 0 0 laz 1D-c2ow w 37.56 61.92 0 0 0 0 0 0 Wall 12B-Osw nw 6.39 2.39 0 0 0 66 422 157 -Glaz 1D-c2ow nw 37.56 43.64 0 0 0 0 0 0 IDoor 11 D0 nw 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osw - 6.39 1.38 0 0 0 0 0 0 Door 11 DO n 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osw - 0.00 0.00 0 0 0 0 0 0 Ceil 16B-19ad - 0.00 0.00 0 0 0 0 0 0 Ceil 16B-50ad - 1.32 1.01 62 82 63 175 231 177 Ceil C part ceiling, - 3.46 2.65 0 0 0 0 0 0 Flor 19A-Obsnsop - 0.00 0.00 0 0 0 0 0 0 Flor 19A-Obsnp - 7.30 1.82 0 0 0 0 0 0 for 19A-30bswp - 1.88 0.47 0 0 0 0 0 0 Infiltration Heating Load(Btuh) 0.44 283 483 Effed WAR WAR 12 Sensible Load(Btuh) ACH 0.03 42 0.06 72 0.26 Latent Load(Btuh) Internal a I Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario m 0 I 0 13 c DefaultAdjnuustiberents di Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines through 12 1018 527 1455 491 Dud EHLF&ESGF 0.073 0.046 0 0 0 0 15 Loads ELG 0 0 16 Ventilation Loads VentCfm 0 E Cfm 0 17 Winter Humidificebon Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion&Latent Moisture Migration Load -29 -34 21 Total Load Sum lines 13 through 19 1018 527 1455 491 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -I.44- wrightsoft- 2023-Ju-1912.18.24 """"" " """'" Right-Suite®Universal 2023 23.0.01 RSU63755 Page 12 `MCA ...Desigrl1Manual J[23-010-0233,Kyle Blodier].np Calc=MJ8 Front Door faces:NE +I+ wrightsoft Right-J8® Form J1 Job: 23-010-0233 System 1 Bate By Dandelion Energy 333 North Bedford Road,State 220,Mout Kisco,NY 10549 Phone:833-GE0-4ALL Email:desion@dandelionenergy.com Web:wwwdardelionenergy.com 1 Name of Room Primary 2 Running Feet of Exposed Wall 30.0 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SqFt) 8.0 ft 480.0 ft' 4 Room Dimensions(Ft)and Floor Plan Area(SqFt) 1.0 x 197.9 ft 197.9 ft' 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SqFt) 0 ° 197.9 ft" Type of 1 Consi, Panel HTM Area or Btuh Area or Btuh Exposure Number Faces - Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 all 12B-0sw ne 6.39 2.39 98 503 188 I�-Glaz 1D-c2ow ne 37.56 43.64 19 723 840 Door 11D0 ne 25.70 10.53 0 0 0 Wall 12B-Osw se 6.39 2.39 0 0 0 111 HGlaz 1D-c2ow se 37.56 54.23 0 0 0 Door 11 D0 se 0.00 0.00 0 0 0 Wall 12B-Osw sw 6.39 2.39 0 0 0 Diaz 1 D-c2osd sw 37.56 54.23 0 0 0 laz 1D-c2ow sw 37.56 54.23 0 0 0 Door 11 D0 sw 0.00 0.00 0 0 0 (Wall 12B Osw w 6.39 2.39 0 0 0 I-Glaz 1D-c2ow w 37.56 61.92 0 0 0 Wall 12B-Osw nw 6.39 2.39 142 852 318 -Glaz 1D-c2ow nw 37.56 43.64 9 329 382 Door 11 D0 rrw 25.70 10.53 0 0 0 Wall 12B-Osw - 6.39 1.38 0 0 0 I Door 11 DO n 25.70 10.53 0 0 0 Wall 12B-0sw - 0.00 0.00 0 0 0 Ceil 168-19ad - 0.00 0.00 0 0 0 Ceil 165-50ad - 1.32 1.01 198 261 200 Ceil C part ceiling, - 3.46 2.65 0 0 0 Flor 19A Obsnp - 0.00 0.00 0 0 0 Flor 19A-Obswp 7.30 1.82 0 0 0 Flor 19A-30bswp - 1.88 0.47 0 0 0 • 1 Infiltration Heating Load(Btuh) 0.44 999 Effect WAR 12 Sensible Load(Btuh) ACH 0.12 148 0.26 Latent Load(Btuh) Internal a Ow pantsat 230 and 200 Btuh 2 460 400 b Scenario number 0 13 c Default Adjustments de Plants I Custom Appliances 0 0 0 14 Subtotals Sum lines6 through 12 3667 2370 Duct EHLF&ESGF 0.073 0.046 0 0 15 Loads ELG 0 16 Ventilation Loads Vent Cfm 0 E Cfm 0 17 Winter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion&Latent Moisture Migration Load -166 21 Total Load Sum lines 131hrough 19 3667 2370 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. vie ri ht '-sort 2023-Ju-1912:18:24 �� rMAartahJ Right-Sute®Universal 202323.0.01 RSU63755 Page 13 ACCA g [23-010-0233,Kyle Blocher].rip Calc=MJ8 Front Door faces:NE Ak 11 N Below Grade Utility Rec Room Job#:23-010-0233 Dandelion Energy Scale: 1 :96 Performed for: Page 1 Kyle Blocher 333 North Bedford Road.Suite 220 Right-Suite®Unhersal 2023 2 Shepherds Hollow Rd Mount Kisco, NY 10549 23.0.01 RSU63755 Northampton, MA01062 Phone: 833-GE0-4ALL 2023-Jul-1912:18:39 ...[23-010-0233,Kyle Blocher]sup www.dardelionenergy.com design@dande[ionenergy.com Ik I' N First Floor Dining Breakfast Kitchen Hall 1 Mudroom Bath 1 Family Foyer Living �. .mmwr Garage .1111111. Job#:23-010-0233 Dandelion Energy Scale: 1 :96 Performed for: Page 2 Kyle Blocher 333 North Bedford Road. Suite 220 Right-Suite®Universal 2023 2 Shepherds Hollow Rd Mount Kisco, NY 10549 23.0.01 RSU63755 Northampton, MA01062 Phone:833 GEO 4ALL 2023-Jul-191218:39 ..[23-010-0233,Kyle Blocherlrup www.dandelionenergy.com design@dandelionenergy.com Ak I►N Second Floor Bath 2 Bed 1 Hall 2 Primary Bed 2 Bath 3 Job#:23-010-0233 Scale: 1 :96 Performed for: Dandelion Energy Page 3 Kyle Blocher 333 North Bedford Road,Suite 220 Right-Suite®Universal 2023 2 Shepherds Hollow Rd Mount Kisco, NY 10549 23.0.01 RSU63755 Northampton, MA01062 Phone: 833-GEO-4ALL ...[23-0110-0233.Kyle Blocher[.rup www.dandelionenergy.com design@dandelionenergy.com NEW EOUIPMENT TO BE INSTALLED: N LOOP 1 GROUND LOOP TIE-IN REAR BASEMENT 1-1/2 IN HDPE . H1161.1111.1.11.11.1 '20 GAL OF GLYCOL MSP1A SP2 SP1 UTILITY N4a87 .41 4Y WI rI S1HP a NEW t=!) z LINE SET PATH Q NEW ,/ STORAGE Ninnin I I c REC ROOM 241C a 1VVO' IP )N pA • A • COLO ROOM aT pN BASEMENT CONTRACTOR NAME: STAMP: PROJECT NAME: PROJECT ID: ( 7M4Ss\ BLOCHER,KYLE 23-010-0233 DANDELIONI CRDA PROJECTADDRESS: DESCRIPTION: PAGE: ECHANICAL y 2 SHEPHERDS HOLLOW RD,NORTHAMPTON,MA o. 55865 01062 NEW EQUIPMENT PLAN SS/ONAL ' IN DATE: 2023 07 18 ACCORDANCEs ;'°`a°u�o�LE 14S,"ou;°"`°"""URVEYOR,TO R`"THI5°, VERSION V2022.08 DRAWN BY: MKK oxoc,,Kerueo SCALE:SEE NTS SIZE:ISO B UX17 Dandelion Heat Pump Packaged Unit Performance Ease of Maintenance i • Two-stage Copeland°UltraTech® • Real-time performance monitoring and 1 compressor with efficiency values up to advanced diagnostic capabilities with home wifi 4.5/20.9(COP/EER) connection.Comes standard with every unit. • Unique compressor isolation technology • Removable cabinet panels and removable and high-density foam cabinet insulation control box providing easy access to internal for ultra-quiet operation components. • EnergyStar certified and made in the USA • Aluminum microchannel air coil which eliminates • Qualifies for the federal tax credit and the potential for failure due to corrosion, E' other state/local incentives enhancing reliability and efficiency --- --- • Corrosion-proof plastic drain pan and conden- 4 sate overflow sensor to protect against potential 1 overflows due to clogged condensate drains • • 3-year workmanship warranty and 10-year Simple Installation limited parts warranty '-'`�, , • Vertical air supply with multi-position, • Digital controls which provide a variety of field -e" field-selectable left or right side return selectable settings for each installation,and ENERGY STAR • Universal connection sizes for ground loop, advanced safety controls to protect the desuperheater and condensate connections equipment • Variable speed,constant cfm ECM blower • Factory-installed soft start which reduces the designed to adapt to connected ductwork start-up power of the heat pump by 70%. and operate at a fraction of the cost of a • Optional field-installed internal auxiliary heating conventional blower motor Performance Ratings Heating Cooling MODEL LOAD SIZE CAPACITY(BTU/HR) COP CAPACITY(BTU/HR) EER BREAKER SIZE(AMPS) Full 19,000 4.3 27,100 19.9 YT 024 2 Ton 30 Part 15,200 4.8 21,400 28.2 YT 036 Full 3 Ton 29,100 4.5 41,200 20.9 40 Part 23,300 5.1 31,500 31.3 Full 39,900 4.3 53,300 20.2 YT 048 4 Ton 40 Part 32,000 4.9 42,600 29.6 Full 49,200 4.1 64,300 19.3 YT 060 5 Ton 50 Part 37,700 4.6 50,000 28.0 YT 072 Full 6 Ton 56,200 3.8 71,900 18.0 60 Part 45,800 4.4 58,500 24.8 Rated in accordance with AHRI/ISO standard 13256-1,which includes pump penalties www.dandelionenergy.com Dimensions ® 1.00 ! o li T� -i._- f - r--I--O 16.0 7.25--t r 16.0 -7 0 7YPTIP I o 4f- o r g 1 °I 1 - =6.56 / I ° I, s ♦. "'----"'- '"'- Enertech Recommends a Minimum Ii of 2 to 2.5 feet of Service/Installation f Access at Front and Air Coil Side. l f f 16.0 / �� TOP VIEW TOP VIEW 4l Showing Optional Filter Rack • a i co0 1.00 max: i r r4'' -t 0 1 l•-T SOURCE 11 HWG WATER WATER IN SOURCEOUT IIIL � HWG 4. WATER WATER , . IN r0 OUT . . • , • . . r, CONFIGURED AS CONFIGURED AS SIDE DISCHARGE BACK DISCHARGE Note:Side and Back urat confDischarge igurations fi ions 1 g � FRONT VIEW are only available in 036 through 072 models. LEFT VIEW , x !,�. .,.rr. . ..dz.. ... ..;e..„rr .. _Fpr, ?. ms,"auk,,.ra-«a z«as.;,ra+za ,, 4; fi •.7,9 x ,4, -s 0, ,,t A v.ex.¢: Y„:, t +.5 Unit Dimensional Data MODEL WITHOUT WITH RETURN SUPPLY OPTIONAL CONTROL BOX CONTROL BOX AIR FLANGE AIR FLANGE FILTER RACK Al *B C A2 D E F G H J K L M N P R 024 46.0 23.0 26.5 53.25 25.0 20.0 19.1 1.92 3.63 11.62 12.5 7.44 1.05 2.34 3.00 3.63 036-048 54.0 25.4 30.5 61.2 28.0 26.0 23.7 2.34 2.25 16.0 16.0 7.26 1.60 2.34 3.29 2.25 060-072 58.4 25.4 30.5 65.6 32.0 26.0 24.0 2.34 2.25 16.0 16.0 7.26 1.60 2.34 3.29 2.25 Notes: All measurements are in inches. Electrical connect.are 1"for high voltage, 1/2"for low voltage. *B(Unit Width)excludes field installed factory supplied flanges. Gravel Loop Water Cod Temp Trend Performance Monitoring 38.10 YA •s. Heat pump comes standard with real-time monitoring to provide the installer Y34.554 /r and homeowner with remote insight into system performance.This includes sss real-time efficiency,energy usage,and status of the refrigerant,air,and ~-�-- ground loop circuits. � 242 . ,. .mWw.r, 34.25 Flow pee Trend � I f r f www.dandelionenergy.com" DANDELION December 22,2023 RE: Compliance with applicable codes and regulations To whom it may concern: Dandelion requires that all design and installation methods and materials comply with all applicable codes and standards, including ANSI/CSA/IGSHPA C448 Series-16(Design and installation of ground source heat pump systems for commercial and residential buildings), M2105 of the 2021 International Residential Code(Ground Source Heat Pump system Loop Piping)and 2021 IECC Residential Provisions with Mass stretch Amendments of 2023(as cited by Ninth Edition of the MA State Building Code 780). We provide a set of internal Design&Installation Standards,Permit Drawings,and Master Service Agreements to enforce this requirement with third party contractors and internal installation crews alike. Therefore,to the best of my knowledge,belief and personal judgment,our permit drawings,design and installation requirements,and scope of work comply with M2105 of the 2023 International Residential Code and 2023 IECC Residential Provisions. If you have any questions,feel free to contact me at rcarda@dandelionenergy.com. Sincerely, Ryan Carda, P.E. Principal Engineer Dandelion Energy,Inc. 0,,,,ffiu I H u,,,,, aN\N..OF..M4S '7, :. RYAN J. , o: CARDA stle4... No.55865 i' '- .o E December 22,2023 '%,9oF .. sTER.°.,�,\ '%,,SS/ONA.ENG \\\\\\ j 0 228 Park Ave S PMB 70212 New York,NY 10003-1502 US DANDELION June 2,2022 RE:Sediment control practices used to install a ground loop as part of a geothermal heating and cooling system installation To whom it may concern: This letter summarizes Dandelion Energy's sediment control practices used during ground loop installation for geothermal heating and cooling applications. In general,Dandelion implements industry-accepted sediment control methods during drilling and trenching activities according to the New York State Department of Environmental Conservation Standard Specifications for Erosion and Sediment Control. The sediment control method(s) implemented on each project vary depending on site-specific conditions,but may include one or more of the following measures: • Mud Processor-Equipment used to manage and process drilling spoils by separating solid and fluid materials removed from the borehole. • Containers-Drilling spoils are typically discharged directly into containers such as heavy-duty woven polypropylene sacks, impermeable 3-ply plastic pools,geotextile filter bags or lined roll-off containers during drilling. • Stockpile Methods-In some instances,drilling spoils or excavated materials from trenching may be temporarily stockpiled and contained using silt fences and/or straw bale dikes to prevent runoff. Excavated material is typically returned to the trench on the same day. • Dust Control-Water is sprayed to wet drilling spoils or excavated materials for dust control as needed. • Trailering-when necessary,tracked rigs will be trailered on and off private property to limit risk of street contamination • Diverter and Dumpster-Some specific drill rigs use a diverter to direct all drill cuttings into a dumpster via a hose.See the attached letter for details and photos of this system. These practices are used to ensure that the highest level of site and environmental protection are achieved as a normal part of system installation. If you have any questions,feel free to contact me at rcarda(adandelionenerev.com. Sincerely, uuuiuiii Ryan Carda, P.E. ,.\`\,lN OF MA ''%,, Principal Engineer ; y� y% Dandelion Energy,Inc. �' RYAN J. o CARDA [�= "`. No.55865 - 6/2/22 %, �,� ................................. ess/0NALEN\ \\\. 0 333 North Bedford Road,Ste 220 Mount Kisco,NY 10549 DANDELION August 19,2022 RE: Insulation requirements for above grade tie-ins To whom it may concern: In general,when installing geothermal ground loop header piping where it penetrates the building envelope, Dandelion's standard method is to do this below grade.This is not possible for some projects and an above grade penetration must be made through the building envelope.Should this be required for a given project,the following requirements must be met: • Above grade piping shall be installed such that it is completely enclosed and insulated(R10 min)on all sides. • The insulated enclosure shall extend from the above grade building entry point to the bottom of the header trench. The installation of above grade piping in an insulated enclosure according to our Design&Installation Standards will provide the necessary protection such that it will have the same performance and service life expectancy of a standard installation. If you have any questions,feel free to contact me at rcarda@dandelionenergy.com. Sincerely, Ryan Carda, PE Principal Engineer Dandelion Energy, Inc. \\\��\11111111111ii,,%\N0FM4, /// RYAN J. CARDA "`. No.55865 "- 8/22/22 °t g-G ..... �SS�ONAL EN"‘\ \I j 333 North Bedford Road,Ste 220 O Mount Kisco,NY 10549 DANDELION August 19,2022 RE: Header Piping Installation Standards In terms of geothermal heat pump system design and performance,lateral header piping is not relied on for heat transfer capacity.The sole purpose of header piping is to carry the fluid from the ground loop to the heat pump and back.As such, Dandelion's header pipe installation requirements are as follows: • The ground loop header piping and manifold shall be located in an exterior trench that runs from the borehole location(s)to building entry point. • The target burial depth for the header piping and manifold is 2 ft below grade,but anywhere between 1-4 ft is acceptable. o The minimum allowable burial depth for insulated header piping shall be 12 inches below grade. o Whenever the header burial depth is less than 4 ft,freeze protection to 15°F is required. o To achieve a 15F freeze protection value,25%propylene glycol shall be used. • Propylene glycol is added to the system as part of the flushing and purging process during the heat pump installation phase of the project. Using the Kusudah-Achenbach equation published in IGSHPAs Residential and Light Commercial Design and Installation Manual to predict soil temperature as a function of soil type, location,time of year and burial depth, it can be shown that the soil temperature at a 1 ft burial depth will not fall below 25-30°F in this region.The requirement to freeze protect with 25%propylene glycol will provide a 10-15°F buffer between the minimum expected soil temperature and the freeze point of the circulating fluid. In order to protect the header piping from damage due to work by other trades,Dandelion requires the installation of warning tape and tracer wire in the trench.Additionally,each customer is given a scaled and dimensioned as-built drawing that shows the location of the borehole(s)and header trench on the property.These measures help to locate and identify the ground loop piping when necessary. As long as the system is installed in accordance with the requirements above, it will perform according to our design specifications and will not be at risk of damage due to freezing or damage. If you have any questions,feel free to contact me at rcarda@dandelionenergv.com. Sincerely, Ryan Carda, P.E. Principal Engineer Dandelion Energy, Inc. 0,01"""',,,„ \P,ZN O.F Mgsf \� RYAN J. 9..G�= iflee.....Cyo CARDA -_ -" No.55865 1" 8/22/22 '',�°t gf�ISTEaE°�`c ,�\ ''///FSSPONAL EN"\\\`\\ 4I O333 North Bedford Road Suite 220 Mount Kisco,NY 10549 DANDELION October 19,2022 RE: Leak Detection&Emergency Shutoff The purpose of this memo is to address the requirements for geothermal heat pump system installation in the state of Massachusetts,specifically Section 9.2, Leak Detection, Emergency Shut-Offs,and Makeup Fluid in the DEP's Guidelines for Ground Source Heat Pump Wells,which states: The GSHP system shall have an automatic shutdown device(s)to minimize refrigerant,antifreeze or oil leaks in the event of a pressure/fluid loss. The shutdown mechanism shall be such that the system can only be reactivated by the GSHP system vendor or other qualified service representative that is qualified to detect and fix(if possible)the leak and conduct a post repair pressurization test. The GSHP that has been shut down due to fluid/pressure loss shall not be reactivated until the final pressurization testing described below in Section 9.6 has successfully been completed. The ability to reactivate the GSHP system that has been shut down due to a pressure/fluid loss shall not be provided to unqualified persons, including the home/building owners/occupants.A makeup fluid tank for either closed-loop or DX GSHP systems shall only be operated manually. The concern is that an automatic makeup fluid injection system could potentially result in the prevention of the activation of the automatic shutdown device in the event of a system fluid leak, thereby resulting in the release of additional refrigerant or antifreeze. To meet the provisions of this requirement, Dandelion: • Exclusively installs closed-loop systems using methods and materials that comply with ANSI/CSA/IGSHPA C448.0-16. • Performs a leak test according to ASTM F2164 to ensure that no leaks are present in the system prior to startup. • Requires the use of pressurized flow centers in our systems,which will not produce flow through the ground loop in the event of a leak. • Requires the installation of geothermal heat pumps that include a lockout alarm(s)in the sequence of operations to disable the compressor and circulating pumps in the event of loss of flow through the ground loop. • Does not install or make provisions for makeup fluid devices in our system. Therefore,when installed according to our Design and Installation Standards,all systems installed by Dandelion meet the requirements of Section 9.2 Leak Detection, Emergency Shut-Offs, and Makeup Fluid. If you have any questions,feel free to contact me at rcardaladandelionenerev.com. Sincerely, Ryan Carda, P.E. \ OF /`�Q�.�N Mg ss ......... Principal Engineer \o�y 9ryG- Dandelion Energy, Inc. RYAN J. o CARDA No.55865 • ..VFGISTER�'�' FFSSION AL ENS\ \.\`` 10-19-2022 \I j O 333 North Bedford Road Suite 220 Mount Kisco,NY 10549 PERFORMANCE RATINGS(AHRUISO 13256-1) COOLING HEATING PRESSURIZED RETURN AIR DUCT MODEL CAPACITY CAPACITY(BTUIHR) EER CAPACITY(BTU/HR) coP FLOW CENTER CONNECTION (W/ FULL LOAD 27.104 19.9 19.000 13 VIBRATION BREAK YT-024 - I S I AND FILTER RACK) PART LOAD 21.400 28.2 15 200 4.8 ��pnuunlg1• FULL LOAD 41.200 20.9 29 100 4.5 a o``p�NN OF M4J% YT-036 J ................J,�rys� PART LOAD 31,500 31.3 23.300 5A YT-048 FULL LOAD 53.300 20.2 39.900 d3 EXPANSION TANK a = S RYAN J. :R,: PART LOAD 42-600 296 32.000 4.9 a CARDA _ FULL LOAD 64.300 19 3 49,200 4.1VT i =`'•: No.55865 -060 cc PART LOAD 50.000 28.0 37,700 4 6 -'',�Bp'�'PfGIST EaE't4Q�,�`�` f............... FULL LOAD 7L900 78.0 56.200 3.8 s �_ i 4/11/22 '''fJ' ON8LE-,VT-072 PART LOAD 58.500 24.8 45,800 44 I x�� "'�iuloInI��`\• �nxx u ROUGH GRADE 1.O\z 4— — x \ r -1 \ . • A�•U� x ACCESS SEAL BUILDING ENTRY I PANEL u PER D& \ xI STANDARDS x I - ICI ° • 1 FT. RECOMMENDED ACCESS l--i PANEL I I CHECK VALVE (WHEN REQUIRED, SEE NOTES) _ 3 J' --� ISOLATION BALL VALVES _ 1 b. v - (REQUIRED) ♦] ° ° e I S I-III-III--II I — �I LEGEND 1-0-1-1 AIR SEPARATOR y 'rr' SYSTEM PRESSURIZATION DETAILS CONDENSATE TO J(I 1L BALL VALVE-MANUAL RANGE MIN. MAX. APPROVED PUMP OR PER AHJ(TRAP N DRAIN VALVE-MANUAL START-UP PRESSURE 30 PSI 60 PSI I"IT"1""""I FLEXIBLEPIPING NOTES: I I mTT CONNECTION DANDELION AIR OPERATION LIMITS (jj- 90°ELBOW WITH PARAMETER COOLING HEATING • LEFT SIDE RETURN SHOWN.UNIT CAN BE CONFIGURED FOR EITHER LEFT-OR RIGHT-HAND RETURN.CONNECTIONS y PT/SENSOR PORT MIN EAT 60'F 45'F MIRRORED FOR RIGHT HAND CONFIGURATION. TEE ▪ APPROVED INTERIOR PIPING MATERIALS:HDPE,PEX AND/OR RUBBER HEATER HOSE.REFER TO DANDELION'S DESIGN 8 CONNECTION-GENERAL MAX EAT 100'F - BO•F INSTALLATION STANDARDS FOR SIZING REQUIREMENTS. PIPING MIN EWT 30'F 20•F • SUPPLY-RETURN LINE SIZES SELECTED PER DANDELION'S DESIGN AND INSTALLATION STANDARDS. MAX EWT 110'F g0•F • ALL INTERIOR PIPING INSULATED WITH CLOSED-CELL INSULATION 6MIN.THICKNESS). PIPING,TUBING, • THE USE OF CHECK VALVES IS REQUIRED WHEN MULTIPLE HEAT PUMPS ARE CONNECTED TO A COMMON(SHARED)GROUND I- HOSE-GENERAL MIN WATER FLOW 2.5 GPM/TON LOOP. SEE SHEETS 2,3,AND 4(OF 4)FOR ADDITIONAL DANDELION SYSTEM REQUIREMENTS. �,� COUPLING-MALE z FEMALE MAX WATER FLOW 3.5 GPM/TON T--I--� MIN AIR FLOW 300 CFM/TON '\ II /�{ EXPANSION TANK CONTRACTOR NAME: PROJECT NAME: PROJECT ADDRESS: 2 Shepherds Hollow Rd DESCRIPTION: ,7� Kyle Blocher Northampton,MA 01062 INTERIOR PIPING(DANDELION VT) �I/ DANDELION MULTI-POSITION VERTICAL PACKAGED VERSION V2022.04 PROJECT ID: 00003779 DATE: 4/24/2024 SCALE:NTS SIZE:ISO_B_11 X 17 HEADER PIPE SIZE PER " / 'OUGH GRADE DESIGN DOCUMENTS STEP-DOWN,STEP-UP r REVERSE RETURN HEADER STEP-DOWN,STEP-UP I—I REVERSE-RETURN HEADER -III—I / \ III II UNDISTURBED SOIL VERTICAL BOREHOLE(OTY AND r (PER D&I STANDARDS) I—III SPACING PER DESIGN DOCUMENTS) I -III=I / I I—I I a�� =_III //\//\//\// III_ bile �m ), 1z FT. -III=1 / I I-I TARGET DEPTFf (SEE NOTES)I III III— BACKFILL -IIII / / / / I I IIIIIIII // // // 1I I I I II I APPROX. 6 IN. GRANULAR BACKFILL \� (NO ROCKS OR LARGE CHUNKS) 1—III ,;:-, II ✓ -III=I ` { —I CALCULATED I — .. ,'',�:,..,;'fir::`,!.:,. .•;. BORE DEPTH HEADER PIPING TRENCH DFTAR eTRENCHING NOTES' THE TARGET HEADER PIPING BURIAL DEPTH IS 2 FT BELOW GRADE, BUT ANYWHERE BETWEEN 1-4 FT IS ACCEPTABLE. • AS PREVIOUSLY INDICATED, THE MINIMUM ALLOWABLE BURIAL DEPTH FOR HEADER PIPING IS 12 INCHES BELOW GRADE. HEADER PIPE SIZE U PER DESIGN DOCUMENTS '_..„ „nin LOO \`o�, 'urnrrr% (FROMPBUILDING) (TOPLY O BUILDING) C-C SPACING PER P RETURN U-BEND QTY AND PIPE SIZE `` ,aVlNOF AI''''', '' .j PER DESIGN DOCUMENTS DESIGN DOCUMENTS 4' RYAN J. `.. a; GROUND LOOP LAYOUT DETAIL ed CARDA i-,E HEADER PIPING DETAIL ` No.55865 `"- GENERAL NOTES -.,Po'.AF6ISTERE.4.:LT�: • ALL UNDERGROUND PIPE FITTINGS/CONNECTIONS MADE VIA HEAT FUSION PER ANSI/CSA/IGSHPA C448.0-16, SECTION 5.4.2 5/26/22 ,°:,,-QS/pNAL-.,,,4 • ALL GROUND LOOP PIPING HOPE, MIN. 160 PSI RATING (PE 3608 OR 4710) PER ANSI/CSA/IGSHPA C448.0-16, SECTION 5.4.2 nnuu0""S • MINIMUM BORE SPACING AND CALCULATED BORE DEPTH PER LOOPLINK RLC • MIN. SEPARATION DISTANCE FROM ALL STRUCTURES AND UTILITIES (FOUNDATION, GAS, SEWER, SEPTIC, PROPERTY LINES, ETC.) IS 10 FT., SYSTEM ANTIFREEZE MUST MEET OR EXCEED AHJ BUILDING CODES UNLESS OTHERWISE SPECIFIED BY THE AHJ. . INSTALL R2 (MIN.) PIPE INSULATION ON HEADER PIPING WHEN CROSSING A WATER/SEWER LINE CONCENTRATIONS BELOW CORRESPOND WITH A FREEZE POINT=15°F . FULL LENGTH GROUTING REQUIRED, 1.20 BTU/HR-FT-F GROUT THERMAL CONDUCTIVITY VALUE ANTIFREEZE CONCENTRATION% • HEADER PIPING MUST BE LAID OUT IN REVERSE-RETURN FASHION AS INDICATED IN THE HEADER DETAIL DRAWING. ANTIFREEZE TYPE BY VOLUME • ALTERNATIVE PIPING LAYOUT/DESIGN MUST BE PRE-APPROVED BY DANDELION. PROPYLENE GLYCOL 25% • SEE SHEETS 1, 3, AND 4 (OF 4) FOR ADDITIONAL DANDELION SYSTEM REQUIREMENTS. • PRIOR TO STARTUP, THE GROUND LOOP SHALL BE FLUSHED AT 2 FPS TO REMOVE AIR/DEBRIS USING A 1.5 HP PURGE PUMP HEAT TRANSFER FLUID MUST COMPLYWITHANSI/CSA/IGSHPA C448.0-16,SECTION 5.7 CONTRACTOR NAME: PROJECT NAME: PROJECT ADDRESS: 2 Shepherds Hollow Rd DESCRIPTION: Kyle Blocher Northampton,MA 01062 \I� DANDELION p GROUND LOOP AND HEADER PIPING VERSION V2022.05 PROJECT ID: 00003779 DATE: 4/24/2024 SCALE:NTS SIZE:ISO_B_11 X 17 (NEW)HEAT PUMP ELECTRICAL PANEL NOTES: REFER TO TABLE FOR BREAKER REQUIREMENTS • ELECTRICAL WORK MUST MEET OR EXCEED ALL APPLICABLE (EXISTING)MAIN ELECTRICAL PANEL BUILDING&ELECTRICAL CODES • WHEN THE DISTANCE FROM THE SERVICE PANEL TO THE HEAT PUMP Li_ 9 •/ IS GREATER THAN 100 FT,CONSULT WITH THE ENGINEERING TEAM • FOR FURTHER REVIEW. ili ■ HEAT PUMP • SEE SHEETS 1,2,AND 3(OF 4)FOR ADDITIONAL DANDELION SYSTEM c REQUIREMENTS. IIMM _ ,,EP`tN10f M4JJ'''', v L W. AUX HEATER o( CARDA No.55865 L :. -490'AFOISTE0.E�.,•,,,,, 8/16/21 ..:::--.- , ''FftS108AE EN,s` nnin,o"o• (C=) (-- p R o O G Rc Rh II= C 0 Y 1 Yt W1 HEAT PUMP Y2 W2 Q Y2 THERMOSTAT 0/B ` ACC- COM TERMINAL BLOCK U® ACC+ cLD oQ O DH O W 1 ECOBEE THERMOSTAT(NEW) CONDENSATE PUMP BREAK(C)WIRE IF CONDENSATE BACKS UP OR MALFUNCTIONS HEAT PUMP ELECTRICAL SPECIFICATIONS AUX HEAT ELECTRICAL SPECIFICATIONS(WHEN APPLICABLE) VOLTAGE/ LRA W/SOFT VOLTAGE/ AUX HEAT KW AUX HEAT AUX HEAT MODEL PHASE/HZ FLA(AMP) LRA(A) START(A) MCA IA) MOP(A) MODEL PHASE/HZ (240V) AMPS 240V) AUX HEAT MCA(A) MOP YT-024 230/1/60 20.9 58.3 17.5 238 35 YT-024 230/1/60 5 20.8 260 30 YT-036 230/1/60 248 83.0 249 287 40 Y1-036 230/1/60 10 41.7 521 60 VT-048 230/1/60 31.9 1040 312 37.2 50 YT-048 230/1/60 10 41.7 521 60 YT-060 230/1/60 39.5 152.9 45.9 46.3 70 YT-060 230/1/60 10 417 52.1 60 YT-072 2301/60 42.1 1729 53.8 49.5 70 YT-072 230/1/60 10 41.7 521 60 CONTRACTOR NAME: PROJECT NAME: Kyle Blocher PROJECT ADDRESS: DESCRIPTION: 2 Shepherds Hollow Rd ELECTRICAL/THERMOSTAT/CONDENSATE DANDELIONNorthampton,MA 01062 PUMP WIRING(DANDELION YT) MULTI-POSITION VERTICAL PACKAGED VERSION V2021.08 PROJECT ID: 00003779 DATE: 4/24/2024 SCALE:NTS SIZE:ISO_B_11 X 17 Dandelion Energy GSHP Design Report Project: [23-010-0233, Blocher] (Project ID:33165) Prepared: 19-J u I-2 02 3 Prepared By: Madison Knox T.C5E Pik by Geo-Connections..Inc Dandelion Energy System Loads System Loads or Peak Loads are calculated based on a variety of details for an individual residence. Assumed occupancy levels, the number of appliances operating, the number of doors & windows and the tightness of the construction all contribute to the amount of energy required to maintain the thermostat set points given the historical extreme weather conditions in your area. The peak loads used in this report were provided as listed in the following table. 1 kBtu/hr= 1.000 Btu/hr Total Total Heating Load Cooling Load Zone (kBtufhr) (kBtu/hr) Zone SHF System 1 (Whole Home) 37.92 28.14 0.910 Total 37.92 28.14 1 of 7 I Mt Kisco, New York Dandelion Energy Equipment Schedule Based on the provided loads, the recommended heat pump schedule for this system is as follows: J. 1 kBtu/hr= 1,000 Btu/hr Heat Cool ' Water I Air 3 Cap. Cap. Flow Flow Zone GSHP QTY (kBtu/hr) (kBtu/hr) (GPM) (CFM) Dandelion Energy- Enertech 40.50 48.20 12.0 1,790 System 1 (Whole Home) Multi-Position Vertical YT-048 1 - 33.80 40.28 High Capacity Totals 40.50 48.20 12.0 Low Capacity Totals 33.80 40.28 - 1. All capacities shown are total. 2. When applicable,hydronic source and load water flows are assumed equal. 3. Air flow rates are reported on a per heat pump basis. For total air flow in a zone,multiply the reported air flow by quantity. 2 of 7 I Mt Kisco, New York Dandelion Energy System 1 (Whole Home) Zone Details The peak loads for each individual zone are used to calculate the total amount of heating & cooling capacity required for a space based on the set points and the climate data for your area. Peak Heating Load 37,917 Btu/hr Peak Cooling Load 28,143 Btu/hr Heating Set Point 72 °F Cooling Set Point 72 °F Heating Offset 0 Btu/hr Space SHF 0.910 GSHP Selection The ground source heat pump below has been selected to maintain comfortable heat- ing & cooling for this zone. Manufacturer Dandelion Energy Model Enertech Multi-Position Vertical YT-048 Heat Pump Type Water to Air Capacity Dual Capacity # Heat Pumps 1 Installed Capacity Check The installed capacity check describes the efficiency and total heating/cooling capacity of the selected ground source heat pump system. This information is used to ensure proper sizing of equipment based on the load represented by this zone. Heating (High Capacity) Cooling (High Capacity) Heating Capacity 40,500 Btu/hr Total Cooling Capacity 48,200 Btu/hr % Sizing 106.8% Sensible Cooling Capacity 36,150 Btu/hr Energy From Geo 99.9% % Oversizing 41.2% Installed COP 3.89 Installed EER 14.39 Balance Point Temp. -3.0 °F Heating (Low Capacity) Cooling (Low Capacity) Heating Capacity 33,800 Btu/hr Total Cooling Capacity 40,277 Btu/hr Sizing 89.1% Sensible Cooling Capacity 30,208 Btu/hr Installed COP 4.25 % Oversizing 18.0% Installed EER 20.96 3 of 7 Mt Kisco, New York Dandelion Energy System 1 (Whole Home) Zone Operating Summary The Zone Operating Summary describes equipment runtime and the total annual power consumption for the GSHP operating in this zone. Heating Cooling High Capacity Runtime 138 hrs High Capacity Runtime 4 hrs Low Capacity Runtime 2,099 hrs Low Capacity Runtime 688 hrs Supplemental Bin Hours 13 hrs Dual Fuel Bin Hours 0 hrs Heat Pump Energy Use 5,317 kWh Heat Pump Energy Use 1,456 kWh Pumping Energy Use 451 kWh Pumping Energy Use 139 kWh Supplemental Energy Use 15 kWh Dual Fuel Energy Use 0 kWh GSHP Operating Cost Breakdown for Zone Name Based on the annual power consumption of the system and the price per kilowatt hour in your area the estimated cost to maintain the set points for this zone are as follows: Heating Cooling HP Cost $1,276.25 HP Cost $349.57 Supplemental Cost $3.67 Pumping Cost $33.52 Dual Fuel Cost $0.00 Total Cost $383.09 Pumping Cost $108.25 Total Cost $1,388.18 72.1% HP Heating Cost OEM 6.1% Pumping Cost-Heating MINI 0.2% Supplemental Heating Cost 19.7% HP Cooling Cost 1.9% Pumping Cost-Cooling 4 of 7 Mt Kisco, New York Dandelion Energy Back-Up System Details Supplemental System Details Supplemental systems operate at the same time as the geothermal heat pump and provide additional heat when the space load is greater than the system capacity. Supplemental System Typt Electric Resistance C': 1.0 Zone Load and Operating Profile 9i• 54 to SC 48 c Q' 701, £` 42 �p • 600 9 §F ` ` r - - - 36-n° o ''a = - - _ _ c 500 _ - 34 S -" 400 2c'r* .4 3 = 300 1S=3 4 -0 200 4. 12 a, r v 100 6 n _ I :1/IMML_ r, oo pp O N D 0 O N M ti 2 (V 2 M N d C VAS 2 r W R 2 C A Temperature(°F) - Heating Load - Low Capacity Heating Operation - High Capacity Heating Operation - Cooling Load - Low Capacity Cooling Operation • High Capacity Cooling Operation I Supplemental Heating I GSHP Heating I GSHP Cooling Heating Cooling Heating Start OAT 57.0 °F Cooling Start OAT 65.0 °F High Capacity Runtime 138 hr High Capacity Runtime 4 hr Low Capacity Runtime 2,099 hr Low Capacity Runtime 688 hr Supplemental Bin Hours 13 hr 5 of 7 I Mt Kisco, New York Dandelion Energy Vertical Bore 15ft cc Earth Temperature Data Location Deep earth (below 20ft) temperature is a function of the average annual air tempera- ture in your region and remains relatively constant regardless of season. Deep Earth Temp ( To 53.0 °F Formation Details The thermal properties of your formation are based on the formation's composition and have a direct impact on the scale of your loopfield. Thermal Conductivity 1.49 Btu/hr ft °F GHEX Summary Heating is dominant. Grout is used inside of all bores in order to protect the deep earth environment from surface contaminants and to provide a more effective contact surface with GHEX piping that optimizes heat transfer between the fluid pumped through your GSHP and the earth. Grade __________ _ __ Grout T.C. 1.20 Btu/hrft °F ----- ____:-.::-:-:::-::-::`-:::: :.:; ::... : : : :: :::::: :;':;; ;�`--- EWTMIra 30.0 °F 0 Backfill -- 0 Formation _ EWTMAX °F • MAX Granular Backfill =_ p Grout Bore Diameter(DB) 5.00 in GHEX Pipe 1.25"DR 13.5 HDPE 4710 DR13.5 _ nrowsk4 max.) a _ X 1 2 1 _ - =_-= __ _-= Bores in Series (NBIS) 1 LB Layout Rows (nrows) 1 SB-1 __=_-__=__ Bores per Row 1 2 0 ( T- Number of Bores 1 I S B o) Bore Spacing (SB) 15.0 ft g 3. DB TOP VIEW DETAIL ,I Design Depth (LB) 387 ft (GENERIC) (GENERIC) Header Pipe 1.50"DR 11.0 HDPE 4710 DR11 6 of 7 I Mt Kisco, New York Dandelion Energy Vertical Bore 18ft cc Earth Temperature Data Location Deep earth (below 20ft) temperature is a function of the average annual air tempera- ture in your region and remains relatively constant regardless of season. Deep Earth Temp ( TG) 53.0 °F Formation Details The thermal properties of your formation are based on the formation's composition and have a direct impact on the scale of your loopfield. Thermal Conductivity 1.49 Btu/hr ft °F GHEX Summary Heating is dominant. Grout is used inside of all bores in order to protect the deep earth environment from surface contaminants and to provide a more effective contact surface with GHEX piping that optimizes heat transfer between the fluid pumped through your GSHP and the earth. Grade Grout T.C. 1.20 Btu/hr ft °F --- - - - - - - - - - -_ ____ EWTMIN 30.0 °F 0 Backfill 0 Formation == EWT 90.0 °F MAX 0 Granular Backfill 1111 - © Grout - - -- "; - Bore Diameter (DB) 5.00 in __ ,,7F _= GHEX Pipe 1.25"DR 13.5 HDPE 4710 DR13 5 ' t � i = nroWS(4 max.) _ II ,r E -1 21 ... _ �4 ' _ ai ; _ Bores in Series (NBIs) 1 = �- 1 _ _ y LB Layout Rows (n ) 1 II rows o F S B I ` 1 ; = Bores per Row 1 1 f - S 45 2 0 _=ri oe._-_--_B-__ t` , -__ Number of Bores 1 __ Bore Spacing (SB) 18.0 ft DB—{ TOP VIEW DETAIL Design Depth (LB) 387 ft (GENERIC) (GENERIC) Header Pipe 1.50"DR 11.0 HDPE 4710 DR11 7 of 7 I Mt Kisco, New York +I+ wrightsoft Building Analysis Dae. 23-010-0233 Entire House By: Dandelion Energy 333 North Bedford Road,Sute 220,Mouit Kisco,NY 10549 Phone:833-GEO-4ALL Email:design@dardelionenergy.com Web:www.dandelionenergy.com Pro'ect Information For: Kyle Blocher 2 Shepherds Hollow Rd,Northampton,MA 01062 Design Conditions Location: Indoor: Heating Cooling Westfield-Barnes,MA,US Indoor temperature(°F) 72 72 Elevation: 271 ft Design TD(°F) 66 16 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 29.2 29.5 Dry bulb(°F) 6 88 Infiltration: Daily range(°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btuhtft2 Btuh %of load Walls 4.0 16267 33.9 Ducts Glazing 33.5 10796 22.5 Doors 6.6 1619 3.4 Infiltration Ceilings 1.1 1958 4.1 Walls Floors 2.1 4909 10.2 Infiltration 2.6 9814 20.4 ."j'_. ; Ducts 2678 5.6 Piping 0 0 Floors Humidification 0 0 Ventilation 0 0 Adjustments 0 Glazing/ Doorsing s Total 48041 100.0 Coolin• Component Btuh/ft2 Btuh %of load Walls 1.0 4187 16.3 Glazing 45.5 14657 57.2 Walls Internal Gains Doors 2.7 663 2.6 Ducts I Ceilings 0.8 1333 5.2 Other Floors 0.1 306 1.2 Ceilings Infiltration 0.3 1237 4.8 ( Doors Ducts 1117 4.4 Ventilation 0 0 Internal gains 2120 8.3 Blower 0 0 Adjustments 0 Glazing Total 25621 100.0 Latent Cooling Load=2522 Btuh Overall U-value=0.145 Btuh/ft2-°F, Window/FloorArea=8.6 Data entries checked. 8 wrightsaft- 2023-Ju-1912:18:24 � ^M.r^.•,- ^•----" Right-Suter6 Universal 202323.0.01 RSU63755 Pa e 1 ACCA g ...DesigrdManual J[23-010-0233,Kyle Blocher].np Calc=MJ8 Front Door faces:NE wrightsoft. Building Analysis D te. 23-010-0233 (Unconditioned) By: Dandelion Energy 333 North Bedford Road,Sute 220,Mowt Kisco,NY 10549 Phone:833-GE0-4ALL Email:desigrOdandelionenergycom Web:www.dandelionenergy.com Pro'ect Information For: Kyle Blocher 2 Shepherds Hollow Rd,Northampton,MA01062 Design Conditions Location: Indoor: Heating Cooling Westfield-Barnes,MA,US Indoor temperature(°F) 72 72 Elevation: 271 ft Design TD(°F) 66 16 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 29.2 29.5 Dry bulb(°F) 6 88 Infiltration: Daily range(°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btuh/ft2 Btuh %of load Walls 0 0 0 Glazing 0 0 0 Doors 0 0 0 Ceilings 0 0 0 Floors 0 0 0 Infiltration 0 0 0 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 0 0 Coolin• Component Btuh/ft2 Btuh %of load Walls 0 0 0 Glazing 0 0 0 Doors 0 0 0 Ceilings 0 0 0 Floors 0 0 0 Infiltration 0 0 0 Ducts 0 0 Ventilation 0 0 Internal gains 0 0 Blower 0 0 Adjustments 0 Total 0 0 Latent Cooling Load=0 Btuh Overall U-value=0.177 Btuh/ft2-°F, Window/FloorArea=2.8% WARNING:window to floor area ratio=2.8%-less than 5%. ' wrightsaft°^ 2023-Ju-1912:18:24 ^- • •—•-•, • Right-Sdte®Uriversal 2023 23.0.01 RSU63755 Page 2 deak ...Design Manual J[23-010-0233,Kyle Blocher].np Calc=MJ8 Front Door faces:NE wrightsoft Building Analysis Date: 23-010-0233 Con by Other By: Dandelion Energy 333 North Bedford Road,Sute 220,Mout Kisco,NY 10549 Phone:833-GE0-4ALL Email:design@dandelionenergycom Web:vvw .dandelionenergy.com Pro•ect Information For: Kyle Blocher 2 Shepherds Hollow Rd,Northampton,MA01062 Design Conditions Location: Indoor: Heating Cooling Westfield-Barnes,MA,US Indoor temperature(°F) 72 72 Elevation: 271 ft Design TD(°F) 66 16 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 29.2 29.5 Dry bulb(°F) 6 88 Infiltration: Daily range(°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btuh/ft2 Btuh %of load Walls 6.4 4679 46.2 Other Glazing 0 0 0 Infiltration Doors 0 0 0 Ceilings 3.2 218 2.2 :., Floors 7.3 3678 36.3 Walls Infiltration 4.2 1466 14.5 Ducts 83 0.8 Piping 0 0 Humidification 0 0 Floors Ventilation 0 0 Adjustments 0 Ceilings Total 10124 100.0 Coolin• Component Btuh/ft2 Btuh %of load Walls 0 0 0 Glazing 0 0 0 Doors 0 0 0 Ceilings 0 0 0 Floors 0 0 0 Infiltration 0 0 0 Ducts 0 0 Ventilation 0 0 Internal gains 0 0 Blower 0 0 Adjustments 0 Total 0 0 Latent Cooling Load=0 Btuh Overall U-value=0.171 Btuhtft2-"F, Window/FloorArea=0.0% WARNING:window to floor area ratio=0.0%-less than 5%. wrightsaft ie- �••^^ 2023-Ju-19 12:18:24 °w Right-SLite® RSU63755 Page 3 ACCP. ...DesigrdMarxial J[23-010-0233,Kyle Blodrer]np Calc=MJ8 Front Door faces:NE wrightsoft® Building Analysis Job:: 23-010-0233 System 1 By: Dandelion Energy 333 North Bedford Road,Sute 220,Moult Kisco,NY 10549 Prone:833-GEO-4ALL Email:design@dandelionenergy.com Web:www.darxtelionenergy.com Pro'ect Information For: Kyle Blocher 2 Shepherds Hollow Rd,Northampton,MA01062 Design Conditions Location: Indoor. Heating Cooling Westfield-Bames,MA,US Indoor temperature(°F) 72 72 Elevation: 271 ft Design TD(°F) 66 16 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grub) 29.2 29.5 Dry bulb(°F) 6 88 Infiltration: Daily range(°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btuh/ft2 Btuh %of load Walls 6.4 11587 30.6 Ducts Glazing 37.6 10796 28.5 Doors 25.7 1619 4.3 Walls Ceilings 1.6 1740 4.6 Infiltration Floors 1.9 1231 3.2 Infiltration 4.2 8348 22.0 Ducts 2595 6.8 PiinHumidification 0 0 Ceilings Ventilation 0 0 Doors Adjustments 0 Glazing Total 37917 100.0 Coolin• Component Btuh/ft2 Btuh %of load Walls 2.3 4187 16.3 Glazing 51.0 14657 57.2 Walls Internal Gains Doors 10.5 663 2.6 Ducts Ceilings 1.2 1333 5.2 InOtherion Floors 0.5 306 1.2 Ceilings Infiltration 0.6 1237 4.8 i Doors Ducts 1117 4.4 Ventilation 0 0 Internal gains 2120 8.3 Blower 0 0 Adjustments 0 Glazing Total 25621 100.0 Latent Cooling Load=2522 Btuh Overall U-value=0.107 Btuh/ft2--°F, Window/FloorArea=14.4% Data entries checked. wrightsc tt 2023-11-1912:18:24 •°^--• --^ RigH-Sate®Universal 2023 23.0.01 RSU63755 Page 4 ACCA - ...DesigrfMarual J[23-010-0233,Kyle Blodter[.nrp Calc=MJ8 Front Door faces:NE +1+ wrightsoft Load Short Form JJoab:: 23-010-0233 Entire House By: Dandelion Energy 333 North Bedford Road,Sute 220,Moult Kisco,NY 10549 Phone:833-GE0-4ALL Email:desigrt[ddandeliorenergycom Web:www.dardelionenergy.com Project Information For: Kyle Blocher 2 Shepherds Hollow Rd,Northampton,MA01062 Design Information Htg Clg Infiltration Outside db(°F) 6 88 Method Simplified Inside db(°F) 72 72 Construction quality Average Design TD(°F) 66 16 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/lb) 29 30 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref. n/a Coil n/a AHRI ref. n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual airflow 0 cfin Actual airflow 0 elm Air flow factor 0 cfrn/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load HtgAVF CIgAVF (ft2) (Btuh) (Btuh) (dill) (dill) System 1 1997 37917 25621 1370 1370 (Unconditioned) 1250 0 0 0 0 Con by Other 504 10124 0 0 0 Entire House 3751 48041 25621 1370 1370 Other equip loads 0 0 Equip.@ 0.93 RSM 23930 Latent cooling 2522 TOTALS 3751 48041 26452 1370 1370 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ wrightsoft" 2023-JJ-1912:18:24 �, Desi rt,Manal�J ,,,..... Righl-Suite® 2023 23.0.01 RSU63755 Page 1 wry ACCb g [23-010-0233,Kyle Blocher].rrp Calc=MJ8 Front Door faces:NE +1+ wrightsoft Load Short Form Job:. 23-010-0233 Da (Unconditioned) By: Dandelion Energy 333 North Bedford Road,Sute 220,Moult Kisco,NY 10549 Phone:833-GE0-4ALL Email:design@dandelionenergy.com Web:wwwdandelionenergy.com Project Information For: Kyle Blocher 2 Shepherds Hollow Rd,Northampton,MA01062 Design Information Htg Clg Infiltration Outside db(°F) 6 88 Method Simplified Inside db(°F) 72 72 Construction quality Average Design TD(°F) 66 16 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(grub) 29 30 x HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual airflow 0 cfrrl Actual airflow 0 cfm Air flow factor 0 ufrn/Btuh Air flow factor 0 cfrn/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load HtgAVF CIgAVF (ft2) (Btuh) (Btuh) (cdrn) (an) Garage 505 0 0 0 0 Mudroom 113 0 0 0 0 Utility 632 0 0 0 0 (Unconditioned) 1250 0 0 0 0 Other equip loads 0 0 Equip.@ 0.93 RSM 0 Latent cooling 0 TOTALS 1250 0 0 0 0 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2023-Ju-1912:18:24 CA9wrlght50ft. Right-Sute®Universal 202323.0.01 RSU63755 Paget .Deli r MarKal J 23-010-0233,Kyle Blocher].rip Calc=MJ8 Front Door faces:NE +1+ wrightsoft Load Short Form Job: 23-010-0233 Con by Other By: Dandelion Energy 333 North Bedford Road,Sute 220,Moint Kisco,NY 10549 Phone:833-GE0-4ALL Email:design dardelionenergy.com Web:wwwdandelionenergy.com Project Information For: Kyle Blocher 2 Shepherds Hollow Rd,Northampton,MA01062 Design Information Htg Clg Infiltration Outside db(°F) 6 88 Method Simplified Inside db(°F) 72 72 Construction quality Average Design TD(°F) 66 16 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(grAb) 29 30 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual airflow 0 al it Actual airflow 0 c,frn Air flow factor 0 cfmBtuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (dfrn) (cfm) Rec Room 504 10124 0 0 0 Con by Other 504 10124 0 0 0 Other equip loads 0 0 Equip.@ 0.93 RSM 0 Latent cooling 0 TOTALS 504 10124 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t w ghtsoft— 2023-Ji-1912:18:24 ^, Wtt� Right-Site®Uriversal202323.0.01 RSU63755 9 ACCA .��.,�....., Page3 ...DesigrMantal J[23-010-0233,Kyle Blocher].np Calc=MJ8 Front Door faces:NE Load Short FormJob: 23-010-0233 +I+ wrightsoftDate: System 1 By: Dandelion Energy 333 North Bedford Road,Sute 220,Moult Kisco,NY 10549 Phone:833-GEO-4ALL Email:design@dardelionenergy.com Web:wwwdandelionenergy.com Project Information For: Kyle Blocher 2 Shepherds Hollow Rd,Northampton,MA01062 Design Information Htg Clg Infiltration Outside db(°F) 6 88 Method Simplified Inside db(°F) 72 72 Construction quality Average Design TD(°F) 66 16 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(grub) 29 30 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model YT-048 Cond YT-048 AHRI ref Coil AHRI ref Efficiency 0 COP Efficiency 0 EER Heating input 0 kW Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual airflow 1370 din Actual airflow 1370 dui Air flow factor 0.036 ulr nBtuh Air flow factor 0.053 din/Btuh Static pressure 0.40 in H2O Static pressure 0.40 in H2O Space thermostat Load sensible heat ratio 0.91 Capacity balance point=0°F Backup: Input=0 kW, Output=0 Btuh, 100 AFUE ROOM NAME Area Htg load Clg load HtgAVF ClgAVF (ft2) (Btuh) (Btuh) (cfm) (Lfrn) Family 253 5340 2950 193 158 Breakfast 126 3552 2664 128 142 Foyer 78 1730 888 62 47 Bath 1 62 0 0 0 0 Living 170 4542 2305 164 123 Hall 1 68 983 297 36 16 Dining 109 4198 3928 152 210 Kitchen 209 2813 3305 102 177 Bed 1 186 3647 2625 132 140 Bed 2 192 3112 1759 112 94 Bath 2 110 1860 1514 67 81 Bath 3 62 1018 527 37 28 Hall2 175 1455 491 53 26 Primary 198 3667 2370 132 127 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2023-Ju-1912:18:24 Desi,Ma xel JF2t 010-0 Right Sute®Universal 2023 23.0.01 RSU63755 Page 4 9 AC N y [ 233,Kyle Blocher].rup Calc=MJ8 Frort Door faces:NE System 1 1997 37917 25621 1370 1370 Other equip loads 0 0 Equip.@ 0.93 RSM 23930 Latent cooling 2522 TOTALS 1997 37917 26452 1370 1370 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightsof- 2023-Jr1-1912:18:24 �� ,..,,, ,,,,,,.,.,,,,,„,,,.,.., Right-Sute®Universal 2023 23.0.01 RSU63755 Page 5 ACC ...DesigrdMarxaal J[23-010-0233,Kyle Blocher].rr.p Calc=MJ8 Front Door faces:NE -F1+ wrightsoft Right-J8® Form J1 Job: 23-010-0233 Entire House Date: By Dandelion Energy 333 North Bedford Road,Sute 220,Mount Kisco,NY 10549 Phone:833-GEO-4ALL Email:design@dandelionenergy.com Web:www.dandelionenergy.com 1 Name of Room Entire House System 1 2 Running Feet of Exposed Wall 533.1 ft 270.3 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SgFt) 8.0 ft 9330.7 ft' 8.0 ft 5943.7 ft' 4 Room Dimensions(Ft)and Floor Plan Area(SgFt) 3750.7 ft' 1997.3 ft' 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SgFt) 0 ° 3750.7 ft' 0 " 1997.3 ft' Type of Const, I Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 12B-0sw ne 4.53 1.17 1030 3922 1011 568 2707 1011 II Glaz 1 D-claw ne 32.33 37.56 144 4639 5390 124 4639 5390 Door 11D0 ne 25.70 10.53 21 540 221 21 540 221 . Wall 12B-0sw se 3.19 1.19 832 2138 798 354 2138 798 11 I Glaz 1D-c2ow se 32.55 47.00 23 732 1058 20 732 1058 Door 11D0 se 0.00 0.00 140 0 0 0 0 0 Wall 12B-0sw sw 3.30 1.23 1018 2798 1045 556 2798 1045 Glaz 1D-c2ovd sw 37.56 54.23 42 1578 2278 42 1578 2278 -Glaz 1 D-slow sv 33.59 48.50 85 2859 I 4129 76 2859 4129 Door 11D0 sw 0.00 0.00 42 0 0 0 0 0 aW II 12&Osw w 6.39 2.39 15 62 23 15 62 23 laz 1 D-c2ow w 37.56 61.92 6 208 343 6 208 343 Wall 12B-0sv nw 5.13 1.43 832 4042 1122 512 3006 1122 -Glaz 1 D-c2ow nw 32.82 38.13 24 779 906 21 779 906 Door 11D0 nw 25.70 10.53 21 540 221 21 540 221 Wall 12B-Osw - 6.39 0.36 538 3305 189 158 876 189 Door 11D0 n 25.70 10.53 21 540 221 21 540 221 Wall 12B-osw - 0.00 0.00 380 0 0 0 0 0 Ceil 16B-19ad - 0.32 0.00 685 218 0 0 0 0 Ceil 16B-50ad - 1.32 1.01 923 1217 932 923 1217 932 Ceil C part ceiling. - 3.46 2.65 151 523 401 151 523 401 Flor 19A-Obswp - 3.24 0.00 1136 I 3678 0 0 0 0 for 19A-Obswp - 0.07 0.02 623 42 10 6 42 10 for 19A-30bs+p - 1.88 0.47 632 1189 296 632 1189 296 Infiltration Heating Load(Btuh) 0.41 9814 8348 Effed WAR WAR 12 Sensible Load(Btuh) ACH 1.00 1237 1.00 1237 - 0.26 Latent Load(Btuh) 1378 1378 Internal a I Occupants at 230 and 200 Btuh 4 920 800 4 920 800 b ScenarioDefaultAdj numberustments 1200 ( 1200 13 c d I Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines through 12 45363 24504 2178 35322 24504 2178 Dud EHLF&ESGF 0.059 0.046 2678 1117 2595 1117 15 Loads ELG 344 344 16 Ventilation Loads Vent Cfm 0 E Cfm 0 0 0 0 0 0 0 17 Winter Humidification Load Gal/Day 0 0 0 18 Piping Load 0 0 19 Blower Heat 0 0 20 AED Excursion&Latent Moisture Ivigration Load 554 554 21 Total Load Sum lines 13 through 19 48041 25621 2522 37917 25621 2522 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -114- wr ql-tsof-' 2023-Ju-1912:18:24 �^LcA """ ""'"""'"-'""'--- Right-Sate®Universal 202323.0.01 RSU63755 Page 1 ...Design\Manual J[23-010-0233,Kyle Blocherl.np Calc=MJ8 Frost Door faces:NE -1-1+ wrightsoft Right-J8® Form J1 Job: 23-010-0233 Entire House Date: ay: Dandelion Energy 333 North Bedford Road,Suite 220,Moult Kisco,NY 10549 Phone:833-GE0-4ALL Email:design@dandelionenergy.com Web:www.dandelionenergy.com 1 Name of Room (Unconditioned) Con by Other 2 Running Feet of Exposed Wall 171.3 ft 91.5 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SqFt) 8.0 ft 2275.0 If 8.0 ft 1112.0 ft' 4 Room Dimensions(Ft)and Floor Plan Area(SqFt) 1249.8 ft' 503.7 ft' 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SqFt) 0 ' 1249.8 If 0 ' 503.7 ft' Type of Const. Panel HTM Area or Btuh Area or Btuh Fvpnsiire Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Healing S-Clg L-Clg 6 Wail - 12B-Osw ne 4.53 1.17 272 0 0 190 1215 0 H -(;laz 1 D-claw ne 32.33 37.56 20 0 0 0 0 0 Door 11 DO ne 25.70 10.53 0 0 0 0 0 0 Wall 12B-0sw se 3.19 1.19 478 0 0 0 0 0 111 1 Glaz 1 D-c2ow se 32.55 47.00 3 0 0 0 0 0 Door 11 D0 se 0.00 0.00 140 0 0 0 0 0 Wall 12B-Osiwt sw 3.30 1.23 462 0 0 0 0 0 Glaz 1D-c2ovd 9,v 37.56 54.23 0 0 0 0 0 0 -Glaz 1 D-c2ow sw 33.59 48.50 9 0 0 0 0 0 Door 11 DO sw 0.00 0.00 42 0 0 0 0 0 Wall 12B Osw w 6.39 2.39 0 0 0 0 0 0 -Glaz 1 D-c2ow w 37.56 61.92 0 0 0 0 0 0 Wall 12B-0sw nw 5.13 1.43 158 0 0 162 1036 0 _all 1 D-c2ow nw 32.82 38.13 3 0 0 0 0 0 Door 11D0 nw 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osw - 6.39 0.36 0 0 0 380 2429 0 Door 11 D0 n 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osw - 0.00 0.00 380 0 0 0 0 0 Ceil 16B-19ad - 0.32 0.00 617 0 0 68 218 0 Cell 16B-50ad - 1.32 1.01 0 0 0 0 0 0 Ceil C part ceiling - 3.46 2.65 0 0 0 0 0 0 Flor 19A-0bsnp - 3.24 0.00 632 0 0 504 3678 0 Flor 19A-Obsnp - 0.07 0.02 617 0 0 0 0 0 Flor 19A-30bsnp - 1.88 0.47 0 0 0 0 • 0 0 Infiltration Heating Load(Btuh) 0.41 0 1466 Effect WAR WAR 12 Sensible Load(Btuh) ACH 1.00 0 1.00 0 - 0.26 - - - Latent Load(Btuh) 0 0 Internal a l Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number I 0 0 13 c DefaultAdjustrnents d I Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines through 12 0 0 0 10041 0 0 Duct EHLF&ESGF 0.008 0 0 0 83 0 15 Loads ELG 0 0 16 Ventilation Loads Vent Cfm 0 E Cfm 0 0 0 0 0 0 0 17 Winter Humidification Load Gal/Day 0 0 0 18 Piping Load 0 0 19 Blower Heat 0 0 20 AED Excursion&Latent Nbisture Migration Load 0 0 21 Total Load Sum lines 13 through 19 0 0 0 10124 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -'ia- rigl-etsofFt- 2023-Ju-1912:18:24 ACCk �� '"""""" Right-Suite®Universal 2023 23.0.01 RSU63755 Page 2 g anual J[23-010-0233,Kyle Blocher-11 p Calc=MJ8 Frort Door faces:NE +1+ wrightsoft Right-J8® Form J1 Job: 23-010-0233 (Unconditioned) Date: By: Dandelion Energy 333 North Bedford Road,Sute 220,Mouit Kisco,NY 10549 Phone:833-GE0-4ALL Email:design@dardelionenergy.com Web:wwwdandelionenergy.com 1 Name of Room (Unconditioned) Garage 2 Running Feet of Exposed Wall 171.3 ft 62.3 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SgFt) 8.0 ft 2275.0 ft' 8.0 ft 800.0 ft' 4 Room Dimensions(Ft)and Floor Plan Area(SgFt) 1249.8 It' 1.0 x 504.9 ft 504.9 ft' 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SgFt) 0 ° 1249.8 ft' 0 ° 504.9 fF Type of Const, Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 128-0sw ne 0.00 0.00 272 0 0 178 0 0 laz 1D-c2ow ne 0.00 0.00 20 0 0 20 0 0 . Door 11 D0 ne 0.00 0.00 0 0 0 0 0 0 Wall 12B-05w se 0.00 0.00 478 0 0 222 0 0 11 I Glaz 1D-c2ow se 0.00 0.00 3 0 0 0 0 0 Door 11DO se 0.00 0.00 140 0 0 140 0 0 Wall 12B-0sw sw 0.00 0.00 462 0 0 34 0 0 Glaz 1 D-c2ovd sw 0.00 0.00 0 0 0 0 0 0 -Glaz 1 D-c2ow sw 0.00 0.00 9 0 0 6 0 0 Door 11 D0 sw 0.00 0.00 42 0 0 0 0 0 Wall 12B-Osw w 0.00 0.00 0 0 0 0 0 0 ' Glaz 1 D-c2ow w 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw nw 0.00 0.00 158 0 0 64 0 0 Glaz 1 D-c2ow nw 0.00 0.00 3 0 0 0 0 0 Door 11D0 nw 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw - 0.00 0.00 0 0 0 0 0 0 I -Door 11 D0 n 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw - 0.00 0.00 380 0 0 0 0 0 Ceil 168-19ad - 0.00 0.00 617 0 0 505 0 0 Ceil 16B-50ad - 0.00 0.00 0 0 0 0 0 0 Ceil C part ceiling, - 0.00 0.00 0 0 0 0 0 0 for 19A-Obsnsp - 0.00 0.00 632 0 0 0 0 0 for 19A-Obswp - 0.00 0.00 617 0 0 505 0 0 Flor 19A-30bswp - 0.00 0.00 0 0 0 0 0 0 Infiltration Heating Load(Btuh) 0 0 0 Effect WAR WAR 12 Sensible Load(Btuh) ACH 1.00 0 0 0 0 Latent Load(Btuh) 0 Internal a I Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 I 0 13 c Default I e Custom Appliances 0 0 0 0 14 Subtotals Sum lines through 12 0 0 0 0 0 Dud EHLF&ESGF 0 0 0 0 0 0 15 Loads ELG 0 0 16 Ventilation Loads Vent Cfm 0 E Cfm 0 0 0 0 17 Winter Humidification Load Gal/Day 0 0 18 Piping Load 0 19 Blower Heat 0 20 AED Excursion&Latent Moisture tOgration Load 0 0 21 Total Load Sum lines 13 through 19 0 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -i'}r wrigFitsoft- 2023-Ju-1912:18:24 '-ZA """"""""""" """""" Right-Sute®Universal 2023 23.0.01 RSU63755 Page 3 ...Desigr\Manual J[23-010-0233,Kyle Bloche/1.r/p Calc=MJ8 Front Door faces:NE +3+ wrightsoft Right-J8® Form J1 Job: 23-010-0233 (Unconditioned) Date: By: Dandelion Energy 333 North Bedford Road,Srite 220,Mouit Kisco,NY 10549 Phone:833-GE0-4ALL Email:design@dandelionenergy.com Web:wwwdandelionenergy.com 1 Name of Room Mudroom Utility 2 Running Feet of Exposed Wall 18.0 ft 91.0 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SgFt) 8.0 ft 367.0 ft' 8.0 ft 1108.0 ft' 4 Room Dimensions(Ft)and Floor Plan Area(SgFt) 18.0 x 6.3 ft 112.5 ft' 1.0 x 632.3 ft 632.3 ft" 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SgFt) 0 ° 112.5 IF 0 ° 632.3 ft' Type of Const, Panel HTM Area or Btuh Area or Btuh Exprxue Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 12B-0sw ne 0.00 0.00 0 0 0 94 0 0 . -Glaz 1D-c2ow ne 0.00 0.00 0 0 0 0 0 0 Door 11D0 ne 0.00 0.00 0 0 0 0 0 0 . Wall 12B-osw se 0.00 0.00 0 0 0 256 0 0 11 I Glaz 1 D-c2ow se 0.00 0.00 0 0 0 3 0 0 Door 11D0 se 0.00 0.00 0 0 0 0 0 0 Wall 12B-0e sw 0.00 0.00 144 0 0 284 0 0 Glaz 1 D-c2owd sw 0.00 0.00 0 0 0 0 0 0 Glaz 1 D-c2ow sw 0.00 0.00 0 0 0 3 0 0 I-Door 11D0 sw 0.00 0.00 21 0 0 21 0 0 IWall 12B Osw w 0.00 0.00 0 0 0 0 0 0 Glaz 1 D-c2ow w 0.00 0.00 0 0 0 0 0 0 (Wall 12B-Osw nw 0.00 0.00 0 0 0 94 0 0 I-Glaz 1 D-c2ow nw 0.00 0.00 0 0 0 3 0 0 IDoor 11D0 nw 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw - 0.00 0.00 0 0 0 0 0 0 -Door 11D0 n 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw - 0.00 0.00 0 0 0 380 0 0 Ceil 16B-19ad - 0.00 0.00 113 0 0 0 0 0 Ceil 16B-50ad - 0.00 0.00 0 0 0 0 0 0 Ceil C part ceiling, - 0.00 0.00 0 0 0 0 0 0 Flor 19A-Obswp - 0.00 0.00 0 0 0 632 0 0 Flor 19A-Obese - 0.00 0.00 113 0 0 0 0 0 Flor 19A-30bsnp - 0.00 0.00 0 0 0 0 0 0 Infiltration Heating Load(Btuh) 0 0 0 Effect WAR WAR 12 Sensible Load(Btuh) ACH 0 0 0 0 0 - Latent Load(Btuh) Internal al Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines6 through 12 0 0 0 0 Dud EHLF&ESGF 0 0 0 0 0 0 15 Loads ELG 0 0 16 Ventilation Loads Vent Cfm 0 E Cfm 0 17 Wnter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion&Latent Moisture Mgration Load 0 0 21 Total Load Sum lines 13 through 19 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - wriglhtsoft 2023-Jd-191218:24 AZ-CA Rigft-Srite®Uriversal 2023 23.0.01 RSU63755 Page 4 ...DesigrtManal J[23-010-0233,Kyle Blocher-Inv Calc=MJ8 Front Door faces:NE +I+ wrightsoft Right-J8® Form J1 Job: 23-010-0233 Con by Other Date: By: Dandelion Energy 333 North Bedford Road,Sute 220,Moral Kisco,NY 10549 Phone:833-GE0-4ALL Email:design@dardelionenergy.com Web:wwwdardelionenergy.com I1 Name of Room Con by Other RecRoom 2 Running Feet of Exposed Wall 91.5 ft 91.5 ft 3 Ceiling Ht(Ft)and Gross WallArea(SqFt) 8.0 ft 1112.0 ft' 8.0 ft 1112.0 ft' 4 Room Dimensions(Ft)and Floor Plan Area(SqFt) 503.7 ft' 1.0 x 503.7 ft 503.7 ft 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SqFt) 0 ' 503.7 ft' 0 ° 503.7 ft Type of Const, Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 12B-Osw ne 6.39 0.00 190 1215 0 190 1215 0 Glaz 1D-c2ow ne 0.00 0.00 0 0 0 0 0 0 Door 11DO ne 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw se 0.00 0.00 0 0 0 0 0 0 11 I Glaz 1D-c2ow se 0.00 0.00 0 0 0 0 0 0 Door 11D0 se 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw sw 0.00 0.00 0 0 0 0 0 0 Glaz 1 D-c2ovd sw 0.00 0.00 0 0 0 0 0 0 -Glaz 1D-c2ow sw 0.00 0.00 0 0 0 0 0 0 Door 11D0 sw 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw w 0.00 0.00 0 0 0 0 0 0 I-Glaz 1D-c2ow w 0.00 0.00 0 0 0 0 0 0 Wall 12B-05w nw 6.39 0.00 162 1036 0 162 1036 0 Glaz 1D-c2ow nw 0.00 0.00 0 0 0 0 0 0 Door 11D0 nw 0.00 0.00 0 0 0 0 0 0 Wall 128-Osw - 6.39 0.00 380 2429 0 380 2429 0 Door 11D0 n 0.00 0.00 0 0 0 0 0 0 Wall 12B-0sw - 0.00 0.00 0 0 0 0 0 0 Ceil 16B-19ad - 3.23 0.00 68 218 0 68 218 0 Ceil 16B-50ad - 0.00 ' 0.00 0 0 0 0 0 0 Ceil C part ceiling. - 0.00 0.00 0 0 0 0 0 0 For 19A-Obsvp - 7.30 I 0.00 504 3678 0 504 3678 0 For 19A-Obswp - 0.00 0.00 0 0 0 0 0 0 Flor 19A-30bswp - 0.00 0.00 0 0 0 0 0 0 Infiltration Heating Load(Btuh) 0.30 1466 1466 Effect WAR WAR 12 Sensible Load(Btuh) ACH 1.00 0 1.00 0 - 0 Latent Load(Btuh) 0 Internal a I Oazipants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 0 13 c DefaultAdjustrnents d l Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines through 12 10041 0 0 10041 0 Dud EHLF&ESGF 0.008 0 83 0 83 0 15 Loads ELG 0 0 16 Ventilation Loads Vent Cfm 0 E Cfm 0 0 0 0 17 Wnter Humidification Load Gal/Day 0 0 18 Piping Load 0 19 Blower Heat 0 20 AED Excursion&Latent Moisture Migration Load 0 0 21 Total Load Sum lines 13 through 19 10124 0 0 10124 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -1'11- wrigFttsotFt` 2023-JU-1912:18:24 •'' """""" Right-Sute®Universal202323.0.01 RSU63755 qC�p� Page 5 ..DesigrAManal J[23-010-0233,Kyle Blocher].rup Calc=MJ8 Front Door faces:NE -4+ wrightsoft Right-J8® Form J1 Job: 23-010-0233 System 1 Date: By: Dandelion Energy 333 North Bedford Road,Sute 220,Moue Kisco,NY 10549 Pt re:833-GE0-4ALL Email:design@dardelionenergy.com Web:www.dardelionenergy.com 1 Name of Room 1 System 1 Family 2 Running Feet of E,q,os d Wall 270.3 ft 38.8 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SgFt) 8.0 ft 5943.7 ft.' 8.0 ft 524.0 ft' 4 Room Dimensions(Ft)and Floor Plan Area(SgFt) 1997.3 ft 12.5 x 20.3 ft 253.1 ft.' I Ceiling Slope(Deg.)and Gross Ceiling Area(SgFt) 0 1997.3 Its 0 ' 253.1 ft Type of Const, Rand HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 all 12B-0sw ne 6.39 2.39 568 2707 1011 100 428 160 f! Claz 1D-c20w ne 37.56 43.64 124 4639 5390 33 1240 1440 Door 11D0 ne 25.70 10.53 21 540 221 0 0 0 Wall 12B-0sw se 6.39 2.39 354 2138 798 48 307 115 11 Glaz 1 D-claw se 37.56 54.23 20 732 1058 0 0 0 Door 11D0 se 0.00 0.00 0 0 0 0 0 0 Wall 12B-0sw sw 6.39 2.39 556 2798 1045 0 0 0 Glaz 1 D-c2oN.d SW 37.56 54.23 42 1578 2278 0 0 0 Glaz 1 D-c2ow sw 37.56 54.23 76 2859 4129 0 0 0 Door 11D0 sw 0.00 0.00 0 0 0 0 1 0 0 Wall 12B-0sw w 6.39 2.39 15 62 23 0 0 0 l Glaz 1 D-c2ow w 37.56 61.92 6 208 343 0 0 0 Wall 12B-0sw nw 6.39 2.39 512 3006 1122 162 825 308 -Glaz 1D-c2ow nw 37.56 43.64 21 779 906 12 451 524 L -Door 11D0 nw 25.70 10.53 21 540 221 21 540 221 Wall 12B-0sw - 6.39 1.38 158 876 189 0 0 0 Door 11D0 n 25.70 10.53 21 540 221 0 0 0 Wall 12B-0sw - 0.00 0.00 0 0 0 0 0 0 Ceil 16B-19ad - 0.00 0.00 0 0 0 0 0 0 Ceil 16B-50ad - 1.32 1.01 923 1217 932 0 0 0 Ceil C part ceiling. - 3.46 2.65 151 523 401 75 259 199 Flor 19A-Obsnp - 0.00 0.00 0 0 0 0 0 0 for 19A-Obsnp - 7.30 1.82 6 42 10 0 0 0 for 19A-30bswp - 1.88 0.47 632 1189 296 0 0 0 Infiltration Heating Load(Btuh) 0.44 8348 1291 Effect WAR WAR 12 Sensible Load(Btuh) ACH 1.00 1237 0.15 191 - 0.26 Latent Load(Btuh) 1378 Internal a Oco pants at 230 and 200 Btuh 4 920 800 0 0 0 b Scenario number 1200 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines through 12 35322 24504 2178 5340 2950 Dud EHLF&ESGF 0.073 0.046 2595 1117 0 0 15 Loads ELG 344 0 16 Ventilation Loads VentCfm 0 E Cfm 0 0 0 0 17 Winter Humidification Load GaliDay 0 0 18 Piping Load 0 19 Blower Heat 0 20 AED Excursion&Latent Moisture Migration Load 554 -207 21 Total Load Sum lines 13 through 19 37917 25621 2522 5340 2950 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - wrightsoft 2023-A1-1912:18:24 A"'ZcA "" .• -' Right-Suite®Universal 2023 23.0.01 RSU63755 Page 6 ...DesigrMAanual J[23-010-0233,Kyle Blocher-Inv Cab =MJ8 Front Door faces:NE +I+ wrightsoft Right-J8® Form J1 Job: 23-010-0233 System 1 Date: By. Dandelion Energy 333 North Bedford Road,Sute 220,Moult Kisco,NY 10549 Phone:833-GE0-4ALL Email:design@dandelionenergy.com Web:www.dardelionenergy.com 1 Name of Room Breakfast Foyer 2 Running Feet of Exposed Wall 22.3 ft 11.3 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SgFt) 8.0 ft 354.7 ff 8.0 ft 408.0 ft 4 Room Dimensions(Ft)and Floor Plan Area(SgFt) 1.0 x 126.2 ft 126.2 ft' 1.0 x 77.8 ft 77.8 ft' 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SgFt) 0 ° 126.2 ft' 0 ° 77.8 ft' Type of Const, 1 Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 12B-Osw ne 6.39 2.39 0 0 0 90 364 136 Glaz 1D-c2ow ne 37.56 43.64 0 0 0 12 451 524 Door 11 D0 ne 25.70 10.53 0 0 0 21 540 221 Wall 12B-osw se 6.39 2.39 0 0 0 0 0 0 11 1 Glaz 1 D-c2ow se 37.56 54.23 0 0 0 0 0 0 Door 11 D0 se 0.00 0.00 0 0 0 0 0 0 Wall 12B-osw sw 6.39 2.39 70 318 119 0 0 0 Glaz 1 D-c2ovd sw 37.56 54.23 0 0 0 0 0 0 Glaz 1D-c2ow sw 37.56 54.23 20 756 1091 0 0 0 Door 11 DO sw 0.00 0.00 0 0 0 0 0 0 Wall 12B-osw w 6.39 2.39 15 62 23 0 0 0 t-Glaz 1D-c2ow w 37.56 61.92 6 208 343 0 0 0 Wall 12B-0aw nw 6.39 2.39 94 601 224 0 0 0 -Glaz 1D-c2ow nw 37.56 43.64 0 0 0 0 0 0 (-Door 11 D0 nw 25.70 10.53 0 0 0 0 0 0 Wall 12B-0sw - 6.39 1.38 0 0 0 0 0 0 I-Door 11 D0 n 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osw - 0.00 0.00 0 0 0 0 0 0 Ceil 16B-19ad - 0.00 0.00 0 0 0 0 0 0 Ceil 16B-50ad - 1.32 1.01 0 0 0 0 0 0 Ceil C part ceiling, - 3.46 2.65 6 20 15 0 0 0 for 19A-Obswp - 0.00 0.00 _ 0 0 0 0 0 0 for 19A-obsnp - 7.30 1.82 6 42 10 0 0 0 Flor 19A-30bsrop - 1.88 0.47 , 120 226 56 0 0 0 Infiltration Heating Load(Btuh) 0.44 746 375 Effect WAR WAR 12 Sensible Load(Btuh) ACH 0.09 111 0.04 56 0.26 Latent Load(Btuh) Internal a I Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 I 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines through 12 2979 2426 1730 888 Duct EHLF&ESGF 0.073 0.046 573 238 0 0 15 Loads ELG 64 0 16 Ventilation Loads VentCfm 0 E Cfm 0 17 W nter Humidification Load Gal/Day 0 18 Piping Load 19 Biover Heat 20 AED Excursion&Latent Moisture Migration Load 432 -49 21 Total Load Sum lines 13 through 19 3552 2664 1730 888 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -Si- wrigFatso?Ft"' 2023-Ju-1912:18:24 ��'+ """""" Right-Sate®Uriversal 2023 23.0.01 RSU63755 Page 7 � .Destgr�M Manual J[23-010-0233,Kyle Blocherl.rup Calc=MJ8 Front Door faces:NE 9 +`+ wrightsoft Right-J8® Form J1 Job: 23-010-0233 System 1 Date: By: Dandelion Energy 333 North Bedford Road,Sute 220,Mount Kisco,NY 10549 Phone:833-GE0-4ALL Email.design@dardeliorenergycom Web:wwwdardelionenergy.com 1 I Name of Room Bath 1 Living 2 Running Feet of Exposed Wall 0 ft 32.3 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SgFt) 8.0 ft 252.0 tt 8.0 ft 536.0 ft' 41 Room Dimensions(Ft)and Floor Plan Area(SgFt) 8.3 x 7.5 ft 61.9 ft' 11.8 x 14.5 ft 170.4 ft' 5 Ceiling Slope(Deg)and Gross Ceiling Area(SgFt) 0 ' 61.9 ft' 0 ° 170.4 fr Type of Const, Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 aUV II 128-Osw ne 6.39 2.39 0 0 0 94 390 146 II-c_laz 1D-c2aw ne 37.56 43.64 0 0 0 33 1240 1440 Door 11D0 ne 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osw se 6.39 2.39 0 0 0 0 0 0 1 1 I Glaz 1 D-c2ow se 37.56 54.23 0 0 0 0 0 0 Door 11D0 se 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw sw 6.39 2.39 0 0 0 0 0 0 Glaz 1 D-c2ovd sw 37.56 54.23 0 0 0 0 0 0 Glaz 1 D-c2ow sw 37.56 54.23 0 0 0 0 0 0 Door 11D0 sw 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw w 6.39 2.39 0 0 0 0 0 0 I Glaz 1 D-c2ow w 37.56 61.92 0 0 0 0 0 0 Wall 12B-Osw nw 6.39 2.39 0 0 0 48 307 115 -Glaz 1D-c2ow nw 37.56 43.64 0 0 0 0 0 0 I-Door 11D0 nw 25.70 10.53 0 0 0 0 0 0 'Wall 12B-05w - 6.39 1.38 0 0 0 116 742 160 -Door 11D0 n 25.70 10.53 0 0 0 0 0 0 •Wall 12B-Osw - 0.00 0.00 0 0 0 0 0 0 Ceil 16B-19ad - 0.00 0.00 0 0 0 0 0 0 Ceil 16B-50ad - 1.32 1.01 0 0 0 0 0 0 Ceil C part ceiling. - 3.46 2.65 0 0 0 71 244 187 Ror 19A-Obsnp - 0.00 0.00 0 0 0 0 0 0 for 19A-obsrop - 7.30 1.82 0 0 0 0 0 0 Flor 19A-30bswp - 1.88 0.47 0 0 0 158 297 74 1 1 Infiltration Heating Load(Btuh) 0.44 0 591 ' Effed WAR WAR 12 Sensible Load(Btuh) ACH 0 0 0.07 88 0.26 Latent Load(Btuh) Internal a I Ocwpants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 0 13 c Default Adjustments di Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 0 0 3809 2099 Dud EHLF&ESGF 0.073 0.046 0 0 733 206 15 Loads ELG 0 86 16 Ventilation Loads Vent Cfm 0 E Cfm 0 17 Winter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Exairson&Latent Moisture Mgration Load 0 -110 21 Total Load Sum lines 13 through 19 0 0 4542 2305 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. _ -�F wrtgFitsott-- 2023-Ju-1912:18:24 A . """""'"""' """"""" Right-Sate®Universal 2023 23.0.01 RSU63755 Page 8 ...DesigrttMan al J[23-010-0233,Kyle Blocher].rup Calc=MJ8 Front Door faces:NE +++ wrightsoft Right-J8® Form J1 Job: 23-010-0233 System 1 Date: By: Dandelion Energy 333 North Bedford Road,Sute 220,Mount Kisco,NY 10549 Phone:833-GE0-4ALL Email:desigrl@dandelionenergy.com Web:wwwdardelionenergy.com 1 I Name of Room Hatt Dining 2 Running Feet of Exposed Wall 5.8 ft 21.0 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SgFt) 8.0 ft 301.0 ft' 8.0 ft 336.0 ft' 4 Room Dimensions(Ft)and Floor Plan Area(SgFt) 11.8 x 5.8 ft 67.6 ft' 9.3 x 11.8 ft 108.7 ft' 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SgFt) 0 ° 67.6 ft' 0 ° 108.7 ft' Type of Const, Panel HTM Area or Btuh Area or Btuh Fxpasiire Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 12B-Osw ne 6.39 2.39 0 0 0 0 0 0 laz 1 D-c2ow ne 37.56 43.64 0 0 0 0 0 0 Door 11 D0 ne 25.70 10.53 0 0 0 0 0 0 Wall 12B-ose se 6.39 2.39 4 26 10 94 553 206 11 1 Glaz 1 D-c2ow se 37.56 54.23 0 0 0 8 282 407 Door 11 D0 se 0.00 0.00 0 0 0 0 0 0 Wall 12B-0sN sw 6.39 2.39 0 0 0 74 205 76 �-Glaz 1 D-c2ovd sv 37.56 54.23 0 0 0 42 1578 2278 I� {laz 1D-c2ow sw 37.56 54.23 0 0 0 0 0 0 Door 11D0 sw 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osv w 6.39 2.39 0 0 0 0 0 0 I-Glaz 1 D-c2ow w 37.56 61.92 0 0 0 0 0 0 Wall 12B-0sw nw 6.39 2.39 0 0 0 0 0 0 -Glaz 1 D-c2ow nw 37.56 43.64 0 0 0 0 0 0 1 Door 11 D0 nw 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osv - 6.39 1.38 42 134 29 0 0 0 Door 11 D0 n 25.70 10.53 21 540 221 0 0 0 Wall 12B-Osw - 0.00 0.00 0 0 0 0 0 0 Cell 16B-19ad - 0.00 0.00 0 0 0 0 0 0 Ceil 16B-50ad - 1.32 1.01 0 0 0 0 0 0 Ceil C part ceiling, - 3.46 2.65 0 0 0 0 0 0 for 19A-0bsnp - 0.00 0.00 0 0 0 0 0 0 Flor 19A-Obsnp - 7.30 1.82 0 0 0 0 0 0 Flor 19A-30bsvp - 1.88 0.47 58 108 27 109 204 51 Infiltration Heating Load(Btuh) 0.44 17 699 Effed WAR WAR 12 Sensible Load(Btuh) ACH 0.00 2 0.08 104 0.26 Latent Load(Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines through 12 824 270 3521 3577 Dud EHLF&ESGF 0.073 0.046 159 27 677 351 15 Loads ELG 34 55 16 Ventilation Loads VentCfm 0 E Cfm 0 17 Wnter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion&Latent Moisture Migration Load -19 455 21 Total Load Sum lines 13 through 19 983 297 4198 3928 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. r wrigFrtsoft• 2023-J1f-1912:18:24 Ac"Ek Rigtt-Sate®Universal 2023 23.0.01 RSU63755 Page 9 ...DesigstMarual J[23-010-0233,Kyle Blodier].rip Calc=MJ8 Front Door faces:NE +I+ wrightsoft Right-J8® Form J1 Job: 23-010-0233 System 1 Date: By: Dandelion Energy 333 North Bedford Road,Sute 220,Moult Kisco,NY 10549 Phone:833-GEO-4ALL Email:design@dandelionenergy.com Web:wwwdardelionenergy.com 1 Name of Room I Kitchen Bed 1 2 Running Feet of Exposed Wall 16.0 ft 28.8 ft 3 Ceiling Ht(Ft)and Gross WallArea(SgFt) 8.0 ft 484.0 ft' 8.0 ft 460.0 ft' 4 Room Dimensions(Ft)and Floor Plan Area(SgFt) 1.0 x 208.6 ft 208.6 ft' 1.0 x 186.3 ft 186.3 ft' 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SgFt) 0 ° 208.6 ft' 0 ° 186.3 IF Type of Const, Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 12B-Osw ne 6.39 2.39 0 0 0 0 0 0 . -Glaz 1D-c2ow ne 37.56 43.64 0 0 0 0 0 0 Door 11D0 ne 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osw se 6.39 2.39 0 0 0 112 639 239 1 1 ` Glaz 1 D-c2ow se 37.56 54.23 0 0 0 12 451 651 Door 11D0 se 0.00 0.00 0 0 0 0 0 0 Wall 128-Osw sw 6.39 2.39 128 684 255 118 631 236 Glaz 1 D-c2oed sw 37.56 54.23 0 0 0 0 0 0 -Glaz 1 D-c2ow sw 37.56 1 54.23 21 789 1139 19 1 723 1044 Door 11D0 sw 0.00 0.00 0 0 0 1 0 0 0 all 12B-osw w 6.39 2.39 0 0 0 0 0 0 laz 1D-c2ow w 37.56 61.92 0 0 0 0 0 0 (Watt 12B-0sw nw 6.39 2.39 0 0 0 0 0 0 1 Glaz 1 D-c2ow nw 37.56 43.64 0 0 0 0 0 0 Door 11D0 nw 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osw - 6.39 1.38 0 0 0 0 0 0 -Door 11D0 n 25.70 10.53 0 0 0 0 0 0 Wall 12B-osw - 0.00 0.00 0 0 0 0 0 0 Ceil 16B-19ad - 0.00 0.00 0 0 0 0 0 0 Ceil 16B-50ad - 1.32 1.01 0 0 0 186 245 188 Ceil C part ceiling. - 3.46 2.65 0 0 0 0 0 0 Flor 19A-Obswp - 0.00 0.00 0 0 0 0 0 0 Flor 19A-Obswp - 7.30 1.82 0 0 0 0 0 0 Flor 19A-30bswp - 1.88 0.47 188 354 88 0 0 0 Infiltration Heating Load(Btuh) 0.44 533 958 Effed WAR WAR 12 Sensible Load(Btuh) ACH 0.06 79 0.11 142 - 0.26 Latent Load(Btuh) Internal a I Occupants at 230 and 200 Btuh 0 0 0 1 230 200 b Scenario number 1200 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines through 12 2359 3009 3647 2625 Dud EHLF&ESGF 0.073 0.046 454 295 0 0 15 Loads ELG 105 0 16 Ventilation Loads Vent Cfm 0 E Cfm 0 17 W nter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion&Latent Moisture Migration Load 248 -104 21 Total Load Sum lines 13 through 19 2813 3305 3647 2625 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ -I-14- wrigFitsoTt- 2023-Ju-1912:18:24 ACCA ..DesiMarxal J 2 Right-Suite® 2023 23.0.01 RSU63755 Page 10 g [3-010-0233,Kyle Blodier].np Calc=MJ8 Front Door faces NE +I+ wrightsoft Right-J8® Form J1 Job: 23-010-0233 System 1 Date: By: Dandelion Energy 333 North Bedford Road,Srite 220,Mout Kisco,NY 10549 Phone:833-GEO-4ALL Email:deagn@dardelionenergy.com Web:www.dardelionenergy.com 1 Name of Room Bed 2 I Bath 2 2 Running Feet of Exposed Wall 26.8 ft 14.5 ft 3 Ceiling Ht(Ft)and Gross WallArea(SqFt) 8.0 ft 464.0 ft' 8.0 ft 364.0 ft' 4 Room Dimensions(Ft)and Floor Plan Area(SqFt) 1.0 x 191.6 ft 191.6 ft" 1.0 x 109.9 ft 109.9 ft' 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SqFt) 0 ° 191.6 ft' 0 ° 109.9 ft' Type of Const, Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Tall 12B-Osw ne 6.39 2.39 118 631 236 0 0 0 Glaz 1D-c2ow ne 37.56 43.64 19 723 840 0 0 0 Door 11D0 ne 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osw se 6.39 2.39 96 614 229 0 0 0 11 I Glaz 1D-c2ow se 37.56 54.23 0 0 0 0 0 0 Door 11D0 se 0.00 0.00 0 0 0 0 0 0 Wall 12B-Osw sw 6.39 2.39 0 0 0 116 641 239 Glaz 1 D-c2ovd sw 37.56 54.23 0 0 0 0 0 0 -Glaz 1D-c2ow sw 37.56 54.23 0 0 0 16 592 854 Door 11D0 sw 0.00 0.00 0 0 0 0 0 0 Wall 128 Osw w 6.39 2.39 0 0 0 0 0 0 laz 1D-c2ow w 37.56 61.92 0 0 0 0 0 0 Wall 12B-0sw nw 6.39 2.39 0 0 0 0 0 0 Claz 1D-c2ow nw 37.56 43.64 0 0 0 0 0 0 Door 11D0 nw 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osw - 6.39 1.38 0 0 0 0 0 0 Door 11D0 n 25.70 10.53 0 0 0 0 0 0 Wall 12B-0sw - 0.00 0.00 0 0 0 0 0 0 Ceil 16B-19ad - 0.00 0.00 0 0 0 0 0 0 Ceil 16B-50ad - 1.32 1.01 192 253 194 110 145 111 Ceil C part ceiling, - 3.46 2.65 0 0 0 0 0 0 Flor 19A-Obswp _ 0.00 0.00 0 0 0 0 0 0 Flor 19A-0bswp 7.30 1.82 0 0 0 0 0 0 for 19A-30bswp - 1.88 0.47 0 0 0 0 0 0 , Infiltration Heating Load(Btuh) 0.44 891 483 Effed WAR WAR 12 Sensible Load(Btuh) ACH 0.11 132 0.06 72 0.26 Latent Load(Btuh) Internal a Occupants at 230 and 200 Btuh 1 230 200 0 0 0 b Scenario number 0 0 13 c Default Adjustments d Cus>nmAppliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines through 12 3112 1759 1860 1514 Dud EHLF&ESGF 0.073 0.046 0 0 0 0 15 Loads ELG 0 0 16 Ventilation Loads Vent Cfm 0 E Cfm 0 17 Wnter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion&Latent Moisture Migration Load -102 238 21 Total Load Sum lines 13 through 19 3112 1759 1860 1514 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ +}r wrig tsoR- 2023-Jt1-1912:18:24 ACk ..DesigriManual J[2 3-010-0233Right-Siite®Uriversal 2023 23.0.01 RSU63755 Page 11 ,Kyle Blodier].rrp Calc=MJ8 Front Door faces:NE +++ wrightsoft Right-J8® Form J1 Job: 23-010-0233 System 1 Date: By. Dandelion Energy 333 North Bedford Road,Sute 220,Mount Kisco,NY 10549 Phone:833-GE0-4ALL Email:design@dardelionenergy.com Web:wwwdandelionenergy.com 1 I Name of Room Bath 3 Hall 2 2 Running Feet of Exposed Wall 8.5 ft 14.5 ft 3 Ceiling Ht(Ft)and Gross WallArea(SgFt) 8.0 ft 276.0 ft' 8.0 ft 704.0 ft' 4 Room Dimensions(Ft)and Floor Plan Area(SqFt) 1.0 x62.1 ft 62.1 ft' 1.0 x 175.2 ft 175.2 fF 5 Ceiling Slope(Deg.)and Gross Ceiling Area(SgFt) 0 ° 62.1 ft 0 ° 175.2 ft' Type of Const. Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 all 12B-0siv ne 6.39 2.39 68 390 146 0 0 0 laz 1D-c2ow ne 37.56 43.64 7 263 306 0 0 0 oor 11 DO ne 25.70 10.53 0 0 0 0 0 0 Wall 12B-osw se 6.39 2.39 0 0 0 0 0 0 11 I. Glaz 1D-c2ow se 37.56 54.23 0 0 0 0 0 0 Door 11 D0 se 0.00 0.00 0 0 0 0 0 0 Wall 12B-03w sw 6.39 2.39 0 0 0 50 320 119 laz 1 D-c2ovd sw 37.56 54.23 0 0 0 0 0 0 laz 1D-c2ow sw 37.56 54.23 0 0 0 0 0 0 Door 11 D0 sw 0.00 0.00 0 0 0 0 0 0 Wall 12B Osw w 6.39 2.39 0 0 0 0 0 0 laz 1D-c2ow w 37.56 61.92 0 0 0 0 0 0 Wall 12B-Osw nw 6.39 2.39 0 0 0 66 422 157 I Glaz 1D-c2ow nw 37.56 43.64 0 0 0 0 0 0 I-Door 11 D0 nw 25.70 10.53 0 0 0 0 0 0 Wall 12B-0sw - 6.39 1.38 0 0 0 0 0 0 Door 11D0 n 25.70 10.53 0 0 0 0 0 0 Wall 12B-Osw - 0.00 0.00 0 0 0 0 0 0 Ceil 16B-19ad - 0.00 0.00 0 0 0 0 0 0 Ceil 166-50ad - 1.32 1.01 62 82 63 175 231 177 Ceil C part ceiling, - 3.46 2.65 0 0 0 0 0 0 For 19A-0bswp - 0.00 0.00 0 0 0 0 0 0 nor 19A-0bswp - 7.30 1.82 0 0 0 0 0 0 For 19A-30bswp - 1.88 0.47 0 0 0 0 0 0 Infiltration Heating Load(Btuh) 0.44 283 483 Effect WAR WAR 12 Sensible Load(Btuh) ACH 0.03 42 0.06 72 - 0.26 Latent Load(Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 13 I b Scenario number 0 I 0 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines through 12 1018 527 1455 491 Dud EHLF&ESGF 0.073 0.046 0 0 0 0 15 Loads ELG 0 0 16 Ventilation Loads VentCfn 0 E Cfm 0 17 Winter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion&Latent Moisture IV gration Load -29 -34 21 Total Load Sum lines 13 through 19 1018 527 1455 491 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. t - wrig1-wtsof- 2023-Ji1-1912:1824 """--''-""'""""""" Right-Site®Urtiversal202323.0.01RSU63755 Page 12 ...DesigriMarxel J[23-010-0233,Kyle Blocher].rup Calc=MJ8 Front Door faces:NE +I+ wrightsoft Right-J8® Form J1 Job: 23-010-0233 System 1 Date: By. Dandelion Energy 333 North Bedford Road,Sute 220,Moult Kisco,NY 10549 Phone:833-GEO-4ALL Email:design@dandelionenergycom Web:www.dandelionenergy.com 1 Name of Room Primary 2 Running Feet of Exposed Wall 30.0 ft 3 Ceiling Ht(Ft)and Gross Wall Area(SgFt) 8.0 ft 480.0 ft" 4 I Room Dimensions(Ft)and Hoar Plan Area(SqFt) 1.0 x 197.9 ft 197.9 ft'5 f Ceiling Slope(Deg.)and Gross Ceiling Area(SqFt) 0 " 197.9 ft' Type of Const, Panel HTM Area or Btuh Area or Btuh Exposure Number Faces - Length - Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 all 12B-0sw ne 6.39 2.39 98 503 188 -(_laz 1 D-c20w ne 37.56 43.64 19 723 840 Door 11D0 ne 25.70 10.53 0 0 0 Wall 12B-Osw se 6.39 2.39 0 0 0 1.1 Glaz 1 D-c2ow se 37.56 54.23 0 0 0 Door 11D0 se 0.00 0.00 0 0 0 Wall 128-0sw sw 6.39 2.39 0 0 0 I Glaz 1 D-c2ovd sw 37.56 54.23 0 0 0 -Glaz 1 D-c2ow sw 37.56 54.23 0 0 0 Door 11D0 sw 0.00 0.00 0 0 0 Wall 12B-Osw w 6.39 2.39 0 0 0 -Glaz 1 D-c2ow w 37.56 61.92 0 0 0 Wall 12B-Osw nw 6.39 2.39 142 852 318 -Glaz 1 D-c2ow nw 37.56 43.64 9 329 382 I-Door 11D0 nw 25.70 10.53 0 0 0 Wall 12B-Osw - 6.39 1.38 0 0 0 -Door 11D0 n 25.70 10.53 0 0 0 Wall 12B-0sw - 0.00 0.00 0 0 0 Cell 16B-19ad - 0.00 0.00 0 0 0 Cell 16B-50ad - 1.32 1.01 198 261 200 Cell C part ceiling. - 3.46 2.65 0 0 0 Ror 19A-Obsap - 0.00 0.00 0 0 0 Flor 19A-0bswp - 7.30 1.82 0 0 0 Flor 19A-30bsnp - 1.88 0.47 0 0 0 Infiltration Heating Load(Btuh) 0.44 999 Effed WAR ' 12 Sensible Load(Btuh) ACH 0.12 148 - 0.26 Latent Load(Btuh) I Internal a Occupants at 230 and 200 Btuh 2 460 400 b Scenario number 0 13 c Default Adjustments d Custom Appliances 0 0 e Plants 0 14 Subtotals Sum lines through 12 3667 2370 Dud EHLF&ESGF 0.073 0.046 0 0 15 Loads ELG 0 16 Ventilation Loads Vent Cfrn 0 E Cfm 0 17 Wnter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion&Latent Moisture Migration Load -166 21 Total Load Sum lines 13 through 19 3667 2370 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ + w g}r riF�to sft- 2023-Ju-1912:18:24 AGCN Right-Suter&Uriversal202323.0.01RSU63755 Page 13 ...De sign\Marxal J[23-010-0233,Kyle Blodierl.np CaIc=MJ8 Front Door faces:NE k I' N Grade Utility Rec Room Job#:23-010-0233 Dandelion Energy Scale: 1 : 96 Performed for: Page 1 Kyle Blocher Right-Suite®Universal 2023 2 Shepherds Hollow Rd 333 North Bedford Road, Suite 220 23.0.01 RSU63755 Northampton,MA 01062 Mount Kisco, NY 10549 2023-Jul-1912:18:39 Phone: 833-GE0-4ALL ...[23-010-0233,Kyle Blocher[.rup wwwdandelionenergy.com design@dandelionenergy.com ►_ IIN First Floor Dining Breakfast Kitchen LJ I Hall 1 Mud room Bath 1 Family Foyer Living Garage Job#:23-010-0233 Dandelion Energy Scale: 1 :96 Performed for: Page 2 Kyle Blocher 333 North Bedford Road, Suite 220 Right-Suite®Uni\ersa12023 2 Shepherds Hollow Rd Mount Kisco, NY 10549 23.0.01 RSU63755 Northampton, MA01062 Phone.833 GE0 4ALL 2023-Jul-1912:18:39 ..[23-010-0233,Kyle Blocherlrup wwwdandelionenergy.com design@dandelionenergycom Second Floor Bath 2 Bed 1 Hall 2 II Primary Bed 2 Bath 3 Job#:23-010-0233 Dandelion Energy Scale: 1 :96 Performed for: Page 3 Kyle Blocher Right-Suite®Universal 2023 2 Shepherds Hollow Rd 333 North Bedford Road,Suite 220 23.0.01 RSU63755 Northampton, A010 2 Mount Kisco, NY 10549 2023-JuI-1912:18:39 Phone:833-GE0-4ALL ...[23-010-0233,Kyle Blodier].rup wwwdandelionenergy.com design@dandelionenergycom