41 HERS Projected PHEC-3334 36 Henry St - ProjectedHome Energy Rating Certificate Rating date: 2024-03-07 46`
Projected Report
Registry I D:
Based on Plans Ekotrope ID: dWPQXABv
Your Home's Estimated Energy Use:
This home meets or exceeds the
criteria of the following:
Use [MlBtu]
Annual Cost
Heating
23.9
$1,S 16
2021 International Energy Conservation Code
Cooling
0.5
$34
Hot Water
2.2
$142
Lights/Appliances
23.1
$1,468
Service Charges
$84
Generation (e.g. Solar)
0.0
$0
Total:
49.8
$3,243
HERS Index
Horne Feature Summary:
Rating Completed by:
More Energy
Horne Type:
Sing le family detached
Model:
NIA
Energy Rater: Rachel Baon
lso
Existing 1<o
Community:
NIA
RESNET VD: 1726523
Homes 130
Conditioned Floor Area:
3,487ft2
Rating Company: Power House Energy Consulting
120
Number of Bedrooms:
3
PO Box9571, North Amherst, MA 01059
10
Reference
ian
Primary Heating System:
Air Source Heat Pump •Electric • 9.7 HSPF2
(413) 835-5162
Home
90
Primary Cooling System:
Air Source Heat Pump • Electric • 18 5EER2
Rating Provider: Energy Raters of Massachusetts
so
Primary Water Heating:
Residential Water Heater • Electric • 3.5 U EF
2 Woodlawn Street Amesbury, MA 01913
70
House Tightness:
1.5 ACH50
978-270-3911
60
Ventilation:
76 CFM • 30 Watts • ERV
40
Duct Leakage to Outside:
10 CFM @ 25Pa (0.38 1100 ft2)
3o TtrisHvme
Above Grade Walls:
R-35
a
20
Ceiling:
Vaulted Roof, R-57
...'.
Zero Energy 0
Window Type:
U-Value: 0.28, SHGC: 0.3
Home 0
Foundation Walls:
R-15
Rachel Balon, Certified Energy Rater
02MRESREf �w
Framed Floor:
R-49
Digitally signed: 317I24at 1:09 PM
Building Specification Summary
Property
36 Henry St
Northampton, MA 01060
PH EC-3334 36 Henry St
Projected
Building Information
Conditioned Area [ft2]
Conditioned Volume [ft3]
Thermal Boundary Area [ft2
Number Of Bedrooms
Housing Type
Organization
Power House Energy Consul
Rachel Balon
413-992-8375
Builder
Stokes and Company
3,486.80
35,235.60
8,552.29
3
Single family detached
Building Shell
Ceiling w/Attic I None
Vaulted Ceiling I R58,HDF+LDF,14i-16,C; U-0.021
Above Grade Walls I R22,LDF1,6-16,+10; U-0.034
Found. Walls I Thermax2 5/8" R15; R-15
Framed Floors I R49, HDF1, 12i-16, R-49
Slabs I R10 under all; R-10
Mechanical Systems
Heating
Cooling
Water Heating
Programmable Thermostat
Ventilation System
Whole House Fan
Lights and Appliances
Percent Interior LED
Percent Exterior LED
Refrigerator (kWhlyr)
Dishwasher Efficiency
Ceiling Fan (CFM/Watt)
Inspection Status
Results are projected
Rating
HERS ERI 41
HERS ERI wlo PV 41
�j
POWE, ASE
£NERGYCOMULTING
Windows [largest] I U-Value: 0.28, SHGC: 0.3
Window/ Wall Ratio 10.07
Window 1 Floor Ratio 10.08
Infiltration 11.5 ACH50
Duct Lkg to Outside 110 CFM @ 25Pa (0.381100 ft2)
Total Duct Leakage 1207 CFM @ 25Pa [Post -Construction]
Air Source Heat Pump • Electric • 9.7 HSPF2
Air Source Heat Pump • Electric • 18 SEER2
Residential Water Heater • Electric • 3.5 UEF
Yes
76 CFM • 30 Watts • ERV
NIA
100%
Clothes Dryer Fuel
Electric
100%
Clothes Dryer CEF
3.5
650.0
Clothes Washer LER (kWhlyr)
152.0
240 kWh
Clothes Washer Capacity
4.2
70.4
Range/Oven Fuel
Electric
Ekotrope RATER -Version 4.2.0.3353
All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report.
Component Loads
Property
36 Henry St
Northampton, MA 01060
PH EC-3334 36 Henry 5t
Projected
18
16
14
12
10
8
::
2 4
2
0
-2
-4
-6
-8
Above -Grade Infiltration & Slabs &
Walls Ventilation Floors
Organization
Power House Energy Consul
Rachel Balon
413-992-8375
Builder
Stokes and Company
Inspection Status
Results are projected
Heating &Cooling Loads
Heating a
�j
POWE, ASE
£NERGYCOMULTING
Roofs ❑ucts Windows & Foundation Internal
❑oors Walls Gains
Cooling 0 Ekotrope RATER -Version 4.2.0.3353
All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report.