18D-069 (14) >� _ __�__ BP-2006-0795 GIS#: COMMtA`' WEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON 1111,Lot: -001 _-�� — Permit: Building Category: NEW COMMERCIAL BUILDING BUILDING PERMIT Permit# BP-2006-0795 . Project# JS-2006-0571 Est. Cost: $477251.00 Fee: $6000.00 PERMISSION IS HEREBY GRANTED TO: _ Const. Class: 2C Contractor: License: Use Group: B,Mixed,S1 Forish Construction Co Inc 027190 Lot Size(sq.ft.): Owner: PVC WEST INC Zoning: GI Applicant: Forish Construction Co Inc AT: 168-190 INDUSTRIAL DR Applicant Address: Phone: Insurance: P 4 BOX358 (413) 568-8624 Workers Compensation WESTFIELDMA01086 ISSUED ON:3/3/2006 0:00:00 TO PERFORM THE FOLLOWING WORK:CONSTRUCT 60 X 200 BLDG & PARKING LOT POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector • `°'(";SII Underground;. - ,. Service: /J1A Meter: /� �OUJQ 61s �p� Footings: Rough:'. ,: ;/,2'..) Rough: �� b House# Foun tion: � � FPS'in/ on- 3'/.So4 ? ' D +�'�" Driveway Final: '' 4/3 O/k 3-o..7.Oj . � Final: Alo7-0K% n f«�� �� 3-a9 oG 1G'�.6'0� Final: � // „i Rough Frame: 3 �� Gas: Fire Department Fireplace/Chimney: Rough /. '44-/ Oil: 1�fP 7 Insulation: O Final:ja 3d>'f Tcv tksi t✓n:`�0 4-6b Smoke: L.0/7 K Final: L�` t 1 I.^'. j (n 2 i 1 o o L/-tn.+% o5 I e f1 a 7 PAU AI Fir- , it)6.S 6PA &LAI TC0 THIS PERMIT MAY BE-REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF' ANY OF ITS RULES AND REGULATIONS. Certificate of Occup ignahtre: ----r----'7Z1..e4,• "- 4";" FeeTvpe: ate Paid: Amount: OLE - 8b3S 6/8/07 Building 3 _ _ 6 0:00:00 $6000. 520�`"� iiiiii10111 Still planning board issues to be resolved final CO can 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Building Commissioner-Anthony Patillo • 168-190 INDUSTRIAL DR BP-2006-0795 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 18D-069 CITY OF NORTHAMPTON Lot: -001 Permit: Building Category:NEW COMMERCIAL BUILDING BUILDING PERMIT Permit# BP-2006-0795 Project# JS-2006-0571 Est. Cost: $477251.00 Fee: $6000.00 PERMISSION IS HEREBY GRANTED TO: Const. Class:2C Contractor: License: Use Group: B,Mixed,Sl Forish Construction Co Inc 027190 Lot Size(sq. ft.): Owner: PVC WEST INC Zoning: GI Applicant: Forish Construction Co Inc AT: 168-190 INDUSTRIAL DR Applicant Address: Phone: Insurance: P 0 BOX358 (413) 568-8624 Workers Compensation WESTFIELDMA01086 ISSUED ON:3/3/2006 0:00:00 TO PERFORM THE FOLLOWING WORK:CONSTRUCT 60 X 200 BLDG & PARKING LOT POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 3/3/2006 0:00:00 $6000.0052863 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Building Commissioner-Anthony Patillo ' r File#BP-2006-0795 APPLICANT/CONTACT PERSON Forish Construction Co Inc ADDRESS/PHONE P 0 BOX358 WESTFIELD (413)568-8624 PROPERTY LOCATION 168-190 INDUSTRIAL DR MAP 18D PARCEL 069 001 ZONE GI THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid QJO3 6i (3 Typeof Construction: CONSTRUCT 60 X 200 BLDG&PARKING LOT(FOUNDATION ONLY) New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 027190 3 sets of Plans/Plot Plan THE F LLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INSMATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commis Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. Versionl.7 Commercial Buildin Permit \iav 15. 2000 Department use only City of Northampton Status of Permit Building Department Curb Cut/Driveway Permit 212 Main Street Sewer/Septic Availability Room 100 Water/Well Availability Northampton, MA 01060 Two Sets of Structural Plans phone 413-587-1240 Fax 413-587-1272 Plot/Site Plans Other Specify APPLICATION TO CONSTRUCT, REPAIR, RENOVATE,CHANGE THE USE OR OCCUPANCY OF,OR DEMOLISH ANY BUILDING OTHER THAN A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office 168-190 Industrial Drive Map i 0 Lot a 6 Unit Zone Overlay District Elm St.District CB District SECTION 2 -PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: PVC West, Inc. 168 Industrial Dr., Suite 3, Northampton, MA jai Name(Print) Current Mailing Address: (413) 584-4250 Signature n � Telephone 2.2 Authorized Agent: Forish Construction Co., Inc. 1111 P.O. Box 358, Westfield, MA 01086 Name(Print) Current Mailing Address: (413) 568-8624 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building $458,751.00 (a) Building Permit Fee 2. Electrical (b) Estimated Total Cost of users $0.00 Construction from(6) 3. Plumbing $0.00 Building Permit Fee the rs _. 4. Mechanical(HVAC) _. 5. Fire Protection $18,500.00' 6. Total=(1 +2+3+4+5) 4477,1S1.oo Check Number gio 3 q jl�,q`o This Section For Official Use Only �'� Building Permit Number Date Issued Signature: Building Commissioner/Inspector of Buildings Date Version1.7 Commercial Building Permit May 15,2000 SECTION 4-CONSTRUCTION SERVICES FOR PROJECTS LESS THAN 35,000 CUBIC FEET OF ENCLOSED SPACE Interior Alterations 0 Existing Wall Signs 0 Demolition 0 Repairs❑ Additions 0 Accessory Building 0 Exterior Alteration 0 Existing Ground Sign❑ New Signs 0 Roofing 0 Change of Use❑ Other ❑ Brief Description Enter a brief description here. Of Proposed Work: SECTION 5-USE GROUP AND CONSTRUCTION TYPE USE GROUP (Check as applicable) CONSTRUCTION TYPE A Assembly CIA-1 ❑ A-2 0 A-3 0 1A I 0 A-4 ❑ A-5 ❑ 1 B ❑ B Business 2A ❑ E Educational ❑ 2B I ❑ F Factory ❑ F-1 ❑ F-2 0 2C 1ffi H High Hazard ❑ 3A ❑ I Institutional ❑ I-1 ❑ 1-2 0 1-3 0 3B ❑ M Mercantile ❑ 4 ❑ R Residential ❑ R-1 ❑ R-2 ❑ R-3 ❑ 5A ❑ S Storage V S-1 P S-2 ❑ 5B ❑ - U Utility ❑ Specify: M Mixed UseLEISpecify: /a $ h., _ ,,,oN 5 6,o.lbe4r L7 S Special Use ❑ Specify: ` 1 COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATIONS,ADDITIONS AND/OR CHANGE IN USE Existing Use Group: None _ , Proposed Use Group: __. Existing Hazard Index 780 CMR 34): None Proposed Hazard Index 780 CMR 34): SECTION 6 BUILDING HEIGHT AND AREA BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION OFFICE USE ONLY Floor Area per Floor(sf) 1ST 0� 1s� 12,000 2nd Q 2nd 0' 3rd I 01 3ro 0 4th 4�' 0 Total Area(sf) Q Total Proposed New Construction (sf) I 12,000 Total Height(ft) Q' Total Height ft 21 7.Water Supply(M.G.L.c.40,§54) 7.1 Flood Zone Information: 7.3 Sewage Disposal System: Public 0 Private 0 Zone Outside Flood Zone❑✓ Municipal 0 On site disposal systems Versionl.7 Commercial Building Permit May 15,2000 8. NORTHAMPTON ZONING Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size 48270 48270 µ_, K_. Frontage 150 150 $. .._ Setbacks Front NA 20 Side L:NA R:NA L:135 R:55 Rear NA 80 Building Height NA 21 Bldg. Square Footage NA 0 % 120d 25 , Open Space Footage (Lot area minus bldg&paved 460d 100 239d 52 parking) #of Parking Spaces 0 21 1 Fill: NA 1300 CY - Building (volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO ® DON'T KNOW 0 YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO Q DON'T KNOW 0 YES i IF YES: enter Book Page and/or Document # B. Does the site contain a brook, body of water or wetlands? NO 0 DON'T KNOW 0 YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained 0 Obtained , Date Issued: C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES 0 NO IF YES, describe size, type and location: To Be Determined E. Will the construction activity disturb(clearing, grading,excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES 0 NO IF YES,then a Northampton Storm Water Management Permit from the DPW is required. Versionl.7 Commercial Building Permit May 15,2000 SECTION 9-PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES-FOR BUILDINGS AND STRUCTURES SUBJECT TO CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116(CONTAINING MORE THAN 35,000 C.F.OF ENCLOSED SPACE) 9.1 Registered Architect: Siegfried Porth Not Applicable CI .__._._ 6634 Name(Registrant): Lid 6t Box .3Sc, t�esktidd rnrl 0I086 Registration Number 08/06/2006 Addres i e . 4 /�� � (413) 568 8624 "` Expiration Date Signature Telephone 9.2 Registered Professional Engineer(s): Name Area of Responsibility Address Registration Number a Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number C Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date 9.3 General Contractor Forish Construction Co., Inc. Not Applicable ❑ Company Name: Eric J. Forish T Responsible In Charge of Construction P.O. Box 358, Westfield,MA 01086 Address X � f(413) 568-8624 Signature Telephone • Versionl.7 Commercial Building Permit May 15,2000 SECTION 9-PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES-FOR BUILDINGS AND STRUCTURES SUBJECT TO CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116(CONTAINING MORE THAN 35,000 C.F.OF ENCLOSED SPACE) 9.1 Registered Architect: Not Applicable 0 Name(Registrant): Registration Number Address •__ Expiration Date Signature Telephone 9.2 Registered Professional Engineer(s): .....Phil %pr i F u tctic+n..........OnI Name Area of Responsibility 2SL1 •Qlecti-ScunA. _Ave. , RRrl^gcJeld, mP.._011o� X 5-r2.0c-r-,--, z,a` 31.41 Address . Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date • Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date 9.3 General Contractor _.._.._...._..............................................................._.........._......_.................................._ Not Applicable Cl Company Name: I Responsible In Charge of Construction Address Signature Telephone Versionl.7 Commercial Building Permit May 15,2000 SECTION 10-STRUCTURAL PEER REVIEW(780 CMR 110.11) Independent Structural Engineering Structural Peer Review Required Yes ® No 0 SECTION 11 -OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT , as Owner of the subject property Forish Construction Co.,Inc. hereby authorize _._ �_... to act o y half, in all tiers relative to work authorized by this building permit application. Signature of Owner Date , as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Print Name Si nature of Owner/Agent Date SECTION 12-CONSTRUCTION SERVICES 10.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: Eric J. Forish License Number P.O. Box 358, Westfield, MA 01086 p 0.. © 7/ l0 Address � Expiration Date (413) 568-8624 1 10 3 log Signature Telephone SECTION 13-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes 0 No O - /7y' te),-/ 6,C Air'P.5'TZI BUILDING DEPARTMENT In accordance with Section 116.2 of the Massachusetts State Building Code, I, •/,_4-4,r,Q/ LJ ,L? 'jry being a Professional Architect, certify that the plans for ,Vs -(J c 7— /A/C. ./Air,zUAzelkkhave been prepared under my supervision and to the best of my knowledge, such plans conform to the provisions of said Code, all acceptable engineering practices and all applicable law ordinances. And, further,that I will comply with the requirements of Section 116.2.2 for the structural portions of the building and submit reports to the Building Department as required by Section 116.2 of the Code. b -4�Ep1EQ p� )?'' ti0v HUNTINGTON, cI :74 MA Signatur ki6634Subscrib tt, • • to before me this / day of 20 O C' de-i: 4 it ft Jz A Notary Public J My commission expires he 4.4,..A' c /1 d av Date • • ENERGY CONSERVATION MANDATORY CHECKLIST FOR NEW CONSTRUCTION ,. ., (OTHER THAN LOW-RISE RESIDENTIAL) 780 CMR, 1301.8.1 Owner/Agent Name: /- V' ''AN /A/G Phone: Owner/Agent Address: City/State/Zip: J<iR T1f4744/2 70/\J) Al4 Project Name: `WAE6NOL-' Site Address: /Gt99///YOUhr/ '/*/. City/Town /S akmzetai/p/GW Applicant's Name: Signature: ✓ Applicant's Phone: Date of Application: I. Envelope Compliance Option (check ONE) ❑ Trade-Off (1304.5)-Attach software Compliance Report(COMcheck-EZ) ❑Appendix J(1301.2-For buildings up to 10,000 sf only)-Attach Appendix J compliance documentation ❑Systems Analysis(1309)-Attach Registered Architect's or Engineer's report INt Prescriptive(1304.2)-Complete this section,and attach copy of applicable Table(1304.2.1 through 13.4.2.12) Climate Zone(from Table 1303.1) ❑ Zone 12a ❑ Zone 13a X Zone 14a a. Gross above-grade wall area (Q, g2,0 sq.ft. b. Total window&glass door area /lo 6 sq.ft. c. Glazing%(100 x b=a) /, % Table#utilized: / ,2,R, II.HVAC (check ONE) ❑ Simple Systems&Equipment(1305.2) ❑Complex Systems&Equipment(1305.3) ❑Systems Analysis(1309)-Attach Registered Architect's or Engineer's report III.Lighting(check ONE) ❑Building Area Method(1308.6.2.1) }Attach Compliance Documentation(COMcheck-EZ or other) ❑ Space-by-Space Method(1308.6.2.2) ❑Systems Analysis(1309)-Attach Registered Architect's or Engineer's report IV.Approval&Acceptance Construction Documents (1301.8.4.1) Attach a narrative report describing the HVAC,Lighting,and Electric Distribution systems,including: For Official Use ONLY: ❑ 1.Design Intent ❑ 2.Basis of Design Building Official ❑ 3. Sequence of operation/systems interaction check off 4.Description of the systems(capacities,etc.) completed sections of report 5.Testing requirements/criteria acceptance ❑,, 6.Requirement for submittal of operation manuals and maintenance manuals ❑` 7.Requirement for submittal of record drawings and control documents This Side For Use by Building Department Only Official's Name: Title: I.Plans Review Date Application Received: n Complete Narrative Report Received(1301.8.4.1) ❑ Design and Specification Documents prepared by legally recognized professional(1301.8.4.3) Application is: Approved ❑ Date: Signature: Denied ❑ Date: Reason(s)for Denial: (provide additional details as needed on separate sheet) II.Acceptance(1301.8.4.4) ❑ Successful system tests witnessed by Building Official,OR ❑ satisfactory test report received(check one) ❑ Certification by Registered Professional(per 780 CMR 116.2)that systems are installed in accordance with construction documents ❑ Confirmation by owner(or their authorized representative)that they have received record drawings, reviewed for reasonable accuracy ❑ Confirmation by owner(or their authorized representative)that they have received reports,controls documentation,operations manual(s),maintenance manual(s),and other documents specified in 1301.8.4.1 Building Official's Signature: TABLE 1304.2.9 BUILDING ENVELOPE REQUIREMENTS Climate Zone 14a Glazin Area 10% or less of Above Grade Wall Area Above-Grade Walls: Continuous Insulation(or Metal Framing Wood Framing Framed or Masonry <35 psf. R-7 R-11 +R-3 c.i. R-11 Masonry>=35 psf. R-5 R-11 +R-3 c.i. R-11 Window Assemblies: SHGC(maximum) U-Value(maximum) PF<0.25 Any 0.7 0.25<=PF<0.50 Any 0.7 PF>=0.50 Any 0.7 Skylights-U-Value X 0.8 Roof Assemblies: (either/or) Insulation Between Framing Continuous Insulation All-Wood Joist/Truss R-19 R-17 Non-wood Joist/Truss R-25 R-18 Concrete Slab or Deck NA R-17 Metal Purlin with Thermal Break R-30 R-18 Metal Purlin w/o Thermal Break X R-18 Floor Assemblies: (either/or) Insulation Between Framing Continuous Insulation All-Wood Joist/Truss R-25 R-18 Non-wood Joist/Truss R-25 R-19 Concrete Slab or Deck NA R-19 Slab,Perimeter,and Below-Grade R-5 wan * For masonry walls, average R-value shall be calculated based on the assumption of isothermal planes, using methodology in 1997 ASHRAE Fundamentals Handbook, Chapter 22. Draft Copy for Educational Purposes Only January 1,2001 Forish Construction TRANSMITTAL PO Box 358 No. 00014 21 Mainline Dr. Phone: 413-568-8624 Westfield,MA 01086 Fax: 413-562-7136 PROJECT: PVC West Inc. DATE: 2/10/2006 TO: NORTHAMPTON BUILDING DEPARTMENT REF: Buildling Permit Application City of Northampton Building Department 212 Main Street Northampton,MA 01060 ATTN: Anthony Patillo WE ARE SENDING: SJTBMITTED FOR: ACTION TAKEN: El Shop Drawings Mi Approval El Approved as Submitted ❑ Letter Z. Your Use ❑ Approved as Noted ❑ Prints ❑ As Requested ❑ Returned After Loan ❑ Change Order ❑ Review and Comment ❑ Resubmit Er Plans El Submit ❑ Samples SENT VIA: El Returned ❑ Specifications Rr Attached ❑ Returned for Corrections El Other: ❑ Separate Cover Via: Hand Delivered ❑ Due Date: COPIES DATE DRAWING NUMBER REV. NO. DESCRIPTION 1 2/7/2006 Building Permit Application Fee Check#52863 1 2/10/2006 Copy of receipt of recording of Planning Decision 1 2/7/2006 Building Permit Application 1 2/9/2006 Fire Protection Narrative and Code Review 1 2/9/2006 Energy Conservation Checklist 1 2/9/2006 Architect's Affidavit 1 10/29/2005 1 OF 3 0 Title:Existing Site Plan(1 OF 3),Revision: (0,Oct 29,2005) 1 2/6/2006 2 OF 3 003 Title:Proposed Site Plan(2 OF 3),Revision: (003,Feb 6,2006) 1 10/29/2005 3 OF 3 0 Title:Details Page(3 OF 3),Revision: (0,Oct 29,2005) 1 10/25/2005 A-1 0 Title:Floor Plan(A-1),Revision: (0,Oct 25,2005) 1 10/25/2005 A-2 0 Title:Elevations(A-2),Revision: (0,Oct 25,2005) 1 12/12/2005 F-1 0 Title:FOUNDATION PLAN(F-1),Revision: (0,Dec 12,2005) 1 12/12/2005 F-2 0 Title:FOUNDATION DETAILS AND SPECS(F-2),Revision: (0,Dec 12,2005) 1 12/8/2005 PE- 1 1 Title:Photometric Plan(PE- 1),Revision: (1,Dec 8,2005) 1 11/30/2005 PL-1 2 Title:Planting Plan(PL-1),Revision: (2,Nov 30,2005) CC: Expedition Forish Construction TRANSMITTAL PO Box 358 No. 00014 21 Mainline Dr. Phone: 413-568-8624 Westfield,MA 01086 Fax: 413-562-7136 PROJECT: PVC West Inc. DATE: 2/10/2006 TO: NORTHAMPTON BUILDING DEPARTMENT REF: Buildling Permit Application City of Northampton Building Department 212 Main Street Northampton, MA 01060 ATTN: Anthony Patillo WE ARE SENDING: SUBMITTED FOR: ACTION TAKEN: ❑ Shop Drawings Approval ❑ Approved as Submitted ❑ Letter Wr Your Use ❑ Approved as Noted ❑ Prints ❑ As Requested ❑ Returned After Loan ❑ Change Order ❑ Review and Comment ❑ Resubmit Yr Plans ❑ Submit ❑ Samples SENT VIA: ❑ Returned ❑ Specifications Wr Attached ❑ Returned for Corrections ❑ Other: ❑ Separate Cover Via: Hand Delivered ❑ Due Date: Remarks: Tony, Copies of the revised siteplan have been sent to the DPW and Planning Department for review and approval as required by the Planning Board Decision. Please note that the tenants for this building have not been fmalized. The Plumbing,HVAC,Electrical,and interior fit-out are not part of our contract with the owner and he has been informed and understands that separate permits will need to be taken out for these items once the tenants and interior floor plan are finalized. Please feel free to call me with any questions or if you need any additional information. Thank you. CC: Signed: o ' Cito Je ey Expedition® Page 2 of 2 FIRE PROTECTION SYSTEM NARRATIVE 780 CMR 903.1.1 FOR PVC-WEST, INC INDUSTRIAL DRIVE NORTHAMPTON, MA 02/08/06 BY SIEGFRIED FORTH 21 MAINLINE DRIVE WESTFIELD,MA 01085 413-568-8624 903.1.1 [ l.a]BASIS [METHODOLOGY]OF DESIGN SECTION 1 —BUILDING DESCRIPTION THE BUILDING IS TO BE DIVIDED INTO TWO EQUAL SPACES-USE GROUP B AND S-1 NOTE:THE OWNER WILL FILE FOR SEPARATE PERMITS FOR ALL FUTURE BUILD OUTS. THE BUILDING WILL BE DESIGNED AS MIXED USE NON-SEPARATED S-1 MODERATE HAZARD IS THE MOST RESTRICTIVE. SECTION 313.1.1 NON SEPARATED USE GROUPS: EACH PORTION OF THE BUILDING SHALL BE INDIVIDUALLY CLASSIFIED AS TO USE.THE REQUIRED TYPE OF CONSTRUCTION FOR THE BUILDING SHALL BE DETERMINED BY APPLYING THE HEIGHT AND AREA LIMITATIONS FOR EACH OF THE APPLICABLE USE GROUPS TO THE ENTIRE BUILDING. THE MOST RESTRICTIVE TYPE OF CONSTRUCTION SO DETERMINED SHALL APPLY. THE OTHER REQUIREMENTS OF 780 CMR SHALL APPLY TO EACH PORTION OF THE BUILDING BASED ON THE USE GROUP OF THAT OCCUPANCY EXCEPT THAT THE MOST RESTRICTIVE APPLICABLE PROVISIONS OF 780 CMR 403.0 HIGH RISE BUILDINGS [NOT APPLICABLE]AND 780 CMR CHAPTER 9 [NON APPLICABLE] SHALL APPLY TO THESE NON SEPARATED USE GROUPS.A FIRE SEPARATION ASSEMBLY IS NOT REQUIRED BETWEEN USE GROUPS,EXCEPT AS REQUIRED BY OTHER SECTIONS OF CMR 780. OTHER SECTIONS OF CMR 780 TABLE 602: FIRE RESISTANCE RATINGS OF STRUCTURE ELEMENTS #4 FIRE PARTITIONS-TENANT SPACES SEPARATIONS -2C UNPROTECTED =0 HOURS a] BUILDING USE GROUP: S-1 MODERATE HAZARD STORAGE IS THE MOST RESTRICTIVE USE GROUP b] TOTAL SQUARE FOOTAGE OF PROPOSED BUILDING: 12,000 SQ.FT. TABLE 503—HEIGHT AND AREA LIMITATIONS OF BUILDINGS USE: S-1, TYPE OF CONSTRUCTION: 2C ALLOWABLE IS:2 STORY,30'HIGH,8,400 SQ.FT. SECTION 506.3: AREA INCREASE DUE TO AUTOMATIC SPRINKLER SYSTEM WHERE A BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH 780 CMR 906.2.1 THE AREA LIMITATION SPECIFIED IN TABLE 503 SHALL BE INCREASED 200%FOR ONE AND TWO STORY BUILDINGS. 8,400 SQ.FT.X 200%=. 16,800 SQ.FT. THEREFORE. 8,400 SQ.FT.PLUS 16,800 SQ.FT.=25,200 SQ.FT. OF ALLOWABLE BUILDING AREA. [OK] c] BUILDING HEIGHT:21'-0"EAVE HEIGHT d] NUMBER OF FLOORS ABOVE GRADE: ONE[1] e] NUMBER OF FLOORS BELOW GRADE: ZERO[0] f] SQUARE FOOTAGE PER FLOOR: 12,000 SQ.FT. g] TYPE OF OCCUPANCY WITHIN THE BUILDING:OFFICES AND B&S-1 h] TYPE OF CONSTRUCTION: 2C UNPROTECTED i] HAZARDOUS MATERIALS:NONE j] HIGH STORAGE:N/A k] SITE ACCESS: A 24' WIDE COMMON DRIVEWAY DIRECTLY OF OFF INDUSTRIAL DRIVE. SECTION-2 APPLICABLE LAWS, REGULATIONS, AND STANDARDS a] 780 CMR CODE SECTIONS"FIRE PROTECTION SYSTEM REQUIREMENTS" SECTION 904: FIRE SUPPRESSION SYSTEMS ARE REQUIRED IN USE GROUP S-1 AND B IN BUILDINGS OF 12,000 S.FT.OR GREATER IN AGGREGATE FLOOR AREA. WE HAVE 12,000 SQ.FT.OF BUILDING THEREFORE A SPRINKLER SYSTEM IS REQUIRED b] NFPA STANDARDS AND EDITIONS WILL USED FOR THE DESIGN OF EACH SPECIFIC FIRE PROTECTION SYSTEM. SECTION-3 -DESIGN RESPONSIBILITY FOR FIRE PROTECTION SYSTEMS a] DESIGN-BUILD,THE INSTALLING CONTRACTOR COMPLETELY DESIGNS AND SPECIFIES AND INSTALLS THE SYSTEM AND CERTIFIES SYSTEM INSTALLATION FOR CODE COMPLIANCE AT COMPLETION. /q TT-A/ Northampton Fire Department w Memorandum To: Tony Patillo From: Duane Nichols Date: March 1, 2006 CC: Brian Duggan Re: PVC Wes, 168-190 Industrial Drive Secondary to a review of the fire protection narrative and plans that were submitted to me for review, I concur with the issuance of a building permit subject to the following conditions. • A Fire Department Emergency Access Key Box is required on the exterior of the structure near the main entrance; a red 120-candela strobe light that actuates upon an alarm condition is required above the Key box. • Engraved key tags and proper keys are placed in the Key Box. • A Fire Alarm Annunciator panel and/or Fire Alarm Control panel needs to be located at the front entrance. All panels need to be clearly marked with red engraved signage with one-inch white lettering clearly identifying panel. • A graphic representation of the structure must be installed at the Fire Alarm Control Panel (FACP) and/or Fire Alarm Annunciator. • Pull stations are required at the exits. Must be double action type. • Horn/Strobes are required throughout the building for occupant notification • Page 1 • 5 lb. ABC fire extinguishers are required under each pull station. • Fire alarm and Fire suppression work permits need to be obtained. • The FD connection for sprinkler system is to be 4" Storz connection with an attached chain, in addition a sign reading "Fire Department Connection" in 3" white letters on a red background is to be mounted above the connection. Also an electric bell, which activates upon water flow, must be located above this sign. • Fire alarm/sprinkler system must be monitored by a UL listed central station or go direct to Northampton Public Safety Dispatch though the city fire alarm system. • Fire alarm and sprinkler plans need to be submitted to Fire Department for review as soon as possible • Page 2