Loading...
2024-01-18 Farlow-Winn ProposedPRELIMINARY NOT FOR CONSTRUCTION WALL KEY = EXISTING 2x4 INTERIOR WALL = EXISTING 2x6 EXTERIOR WALL = EXISTING 2x4 HALF WALL = DEMO. 2x4 INTERIOR WALL = DEMO. 2x6 EXTERIOR WALL = DEMO 2x4 HALF WALL Specifications Division 1: General Requirements 1.Contractor will obtain all necessary permits for construction, except that owner shall be responsible for water, sewer, electric, and cable fees, if any. 2.Contract excludes approvals by zoning board of appeals, planning board and/or conservation commission. 3.Contract excludes architectural oversight. 4.Any other requirements from town not explicitly included in the plans or specs are not included in this contract. 5.Site survey is not included 6.Contractor has not tested for lead, asbestos, radon, and other hazardous materials and contract does not include any remediation or abatement work. 7.All owner-supplied items are not under warranty by Integrity or Integrity’s sub-contractors and suppliers. Any owner-supplied items that arrive damaged, late or incomplete may cause delays to the schedule and Integrity will not be held liable for such delays or costs. 8.All construction debris will be placed in an onsite dumpster provided by contractor and removed by contractor at contractor ’s expense. 9.Contractor shall promptly remove all construction equipment and materials from site at conclusion of construction. 10.All utilities used during construction are the owner ’s responsibility. 11.Wherever contractor drawing or specification states, “match existing,” such language shall mean “match existing as closely as possible from currently available stock items purchased locally”. 12.All dimensions are framing to framing unless otherwise specified. 13.All existing structural components to remain unless otherwise specified. 14.Appliances, furniture, etc. shown on plans are to be supplied by owner. 15.No winter conditions are included. 16.Contract includes both on-site and in-office job coordination 17.Contractor will supply required insurances, including General Liability and Worker's Compensation 18.Use drop cloths and floor protection to protect flooring from front door to back porch. Replace as necessary. 19.Contractor to supply temporary sanitary facilities on site for workers' use 20.All work is limited to back porch unless otherwise noted 7" UP Division 8: Doors & Windows Doors 1.Remove & discard (2) doors per plan Windows 1.None Division 9: Finishes Wall And Ceiling Finishes 1.Remove & discard beadboard on existing half-walls 2.Remove & discard beadboard on porch ceiling Flooring 1.Remove & save decking for owner's reuse if possible Tile 1.None Interior Trim And Carpentry 1.Remove & discard casings at removed doors Divisions 10-14: Specialties, Equipment, Furnishings, Special Construction, Conveying Systems 1.None Division 15: Mechanical Plumbing 1.None Heating 1.None Division 16: Electrical 1.See Electrical Plan For Specifications NO WORKNO WORKNO WORK REMOVE & DISCARD 3/4"TRIM ON THESE WALLS Demo. Specifications Division 2: Site Work 1.None Division 3: Concrete 1.Selective demo will determine whether existing piers meet current code; if piers are found to be nonexistent or insufficient, cost to remove & discard will be extra to contract Divisions 4-5: Masonry, Metals 1.None Division 6: Wood & Plastics 1.Existing porch framing, including joists, beams, and roof framing, to remain; if framing is insufficient, cost to replace would be extra to contract 2.Remove & discard 2x4 porch half-walls 3.Remove & discard steps and landing facing driveway; piers are assumed to remain 4.Remove & discard 2x4 porch posts only; 4x4 posts to remain Division 7: Thermal & Moisture Protection Exterior Trim And Siding 1.Remove & discard 3/4" trim on exterior walls of back porch 2.Remove & discard all screening on back porch Insulation 1.NoneDevelopment & Construction, Inc.110 Pulpit Hill RoadAmherst, Ma 01002413-549-7919 EMAIL: INFO@INTEGBUILD.COM© Integrity Development & Construction, Inc. (2023). All rights reserved.DESIGN BY NWFARLOW - WINNRESIDENCE1INTEGRITYA- SHEET: DATE: 2/16/2024CONTRACT &BUILDING PERMIT SET184 FEDERAL ST, FLORENCE, MA 01062PORCH FINISHINGCONTRACT AGREED BY: ____________________________________________________________________________ LESLEY FARLOW - OWNER OF 184 FEDERAL ST, FLORENCE, MA 01062 ____________________________________________________________________________ STEVEN WINN - OWNER OF 184 FEDERAL ST, FLORENCE, MA 01062 ____________________________________________________________________________ OWNER FOR INTEGRITY DEVELOPMENT & CONSTRUCTION, INC. FA RLOW - WI NN RESI DENCE 184 FEDERAL ST, FLORENCE, MA 01062 INDEX A -1 A -2 A -3 A -4 A -5 E-1 TI TLE PA GE EXI STI NG FI RST FLOOR PLA N PROPOSED FIRST FLOOR PLA N PROPOSED SECTIONS & LA NDING PLA NS PROPOSED ELEVA TIONS EXI STI NG & PROPOSED ELECTRI CA L PLA N PRELIMINARY NOT FOR CONSTRUCTION DN TO REMAINTO REMAINTO REMAINTO REMAIN TO REMAIN TO REMAIN TO REMAIN TO REMAIN TO REMAIN TO REMAINREMOVE & SAVETO REMAINTO REMAINREMOVE & DISCARDTO REMAINTO REMAINTO REMAIN REMOVE & DISCARD REMOVE & DISCARDDN 2'-5 7/8"3'-0 1/2"3 1/2"3'1 1/2"2'-11 5/8"3 1/2"2'-11 3/4"1 1/2"2'-11 7/8"3 1/2"2'-11 3/4"1 1/2"3'3'-0 1/2"3 1/2"1'-10 1/4"1 1/2"1'-10 1/4"3 1/2"4'-1"4'WALL KEY = EXISTING 2x4 INTERIOR WALL = EXISTING 2x6 EXTERIOR WALL = EXISTING 2x4 HALF WALL = DEMO. 2x4 INTERIOR WALL = DEMO. 2x6 EXTERIOR WALL = DEMO 2x4 HALF WALL BACK PORCH KITCHEN MUD ROOM CLOSET Specifications Division 1: General Requirements 1.Contractor will obtain all necessary permits for construction, except that owner shall be responsible for water, sewer, electric, and cable fees, if any. 2.Contract excludes approvals by zoning board of appeals, planning board and/or conservation commission. 3.Contract excludes architectural oversight. 4.Any other requirements from town not explicitly included in the plans or specs are not included in this contract. 5.Site survey is not included 6.Contractor has not tested for lead, asbestos, radon, and other hazardous materials and contract does not include any remediation or abatement work. 7.All owner-supplied items are not under warranty by Integrity or Integrity’s sub-contractors and suppliers. Any owner-supplied items that arrive damaged, late or incomplete may cause delays to the schedule and Integrity will not be held liable for such delays or costs. 8.All construction debris will be placed in an onsite dumpster provided by contractor and removed by contractor at contractor’s expense. 9.Contractor shall promptly remove all construction equipment and materials from site at conclusion of construction. 10.All utilities used during construction are the owner’s responsibility. 11.Wherever contractor drawing or specification states, “match existing,” such language shall mean “match existing as closely as possible from currently available stock items purchased locally”. 12.All dimensions are framing to framing unless otherwise specified. 13.All existing structural components to remain unless otherwise specified. 14.Appliances, furniture, etc. shown on plans are to be supplied by owner. 15.No winter conditions are included. 16.Contract includes both on-site and in-office job coordination 17.Contractor will supply required insurances, including General Liability and Worker's Compensation 18.Use drop cloths and floor protection to protect flooring from front door to back porch. Replace as necessary. 19.Contractor to supply temporary sanitary facilities on site for workers' use 20.All work is limited to back porch unless otherwise noted 7" UP Division 8: Doors & Windows Doors 1.Remove & discard (2) doors per plan Windows 1.None Division 9: Finishes Wall And Ceiling Finishes 1.Remove & discard beadboard on existing half-walls 2.Remove & discard beadboard on porch ceiling Flooring 1.Remove & save decking for owner's reuse if possible Tile 1.None Interior Trim And Carpentry 1.Remove & discard casings at removed doors Divisions 10-14: Specialties, Equipment, Furnishings, Special Construction, Conveying Systems 1.None Division 15: Mechanical Plumbing 1.None Heating 1.None Division 16: Electrical 1.See Electrical Plan For Specifications NO WORK NO WORK NO WORK REMOVE & DISCARD 3/4" TRIM ON THESE WALLS Demo. Specifications Division 2: Site Work 1.None Division 3: Concrete 1.Selective demo will determine whether existing piers meet current code; if piers are found to be nonexistent or insufficient, cost to remove & discard will be extra to contract Divisions 4-5: Masonry, Metals 1.None Division 6: Wood & Plastics 1.Existing porch framing, including joists, beams, and roof framing, to remain; if framing is insufficient, cost to replace would be extra to contract 2.Remove & discard 2x4 porch half-walls 3.Remove & discard steps and landing facing driveway; piers are assumed to remain 4.Remove & discard 2x4 porch posts only; 4x4 posts to remain Division 7: Thermal & Moisture Protection Exterior Trim And Siding 1.Remove & discard 3/4" trim on exterior walls of back porch 2.Remove & discard all screening on back porch Insulation 1.None AV Control 110V Receptacles: Duplex, Weather Proof, GFCI Switches: Single Pole, Weather Proof, 3-Way, 4-Way Switches: Dimmer, Timer Audio Video: Control Panel, Switch Wall Jacks: CAT5, CAT5 + TV, TV/Cable Door Chime, Door Bell Button Speakers: Ceiling Mounted, Wall Mounted WALL KEY= EXISTING 2x4 INTERIOR WALL= EXISTING 2x6 EXTERIOR WALL= EXISTING 2x4 HALF WALL= DEMO. 2x4 INTERIOR WALL= DEMO. 2x6 EXTERIOR WALL = DEMO 2x4 HALF WALL Specifications Division 1: General Requirements 1.Contractor will obtain all necessary permits for construction, except that owner shall be responsible for water, sewer, electric, and cable fees, if any. 2.Contract excludes approvals by zoning board of appeals, planning board and/or conservation commission. 3.Contract excludes architectural oversight. 4.Any other requirements from town not explicitly included in the plans or specs are not included in this contract. 5.Site survey is not included 6.Contractor has not tested for lead, asbestos, radon, and other hazardous materials and contract does not include any remediation or abatement work. 7.All owner-supplied items are not under warranty by Integrity or Integrity’s sub-contractors and suppliers. Any owner-supplied items that arrive damaged, late or incomplete may cause delays to the schedule and Integrity will not be held liable for such delays or costs. 8.All construction debris will be placed in an onsite dumpster provided by contractor and removed by contractor at contractor ’s expense. 9.Contractor shall promptly remove all construction equipment and materials from site at conclusion of construction. 10.All utilities used during construction are the owner ’s responsibility. 11.Wherever contractor drawing or specification states, “match existing,” such language shall mean “match existing as closely as possible from currently available stock items purchased locally”. 12.All dimensions are framing to framing unless otherwise specified. 13.All existing structural components to remain unless otherwise specified. 14.Appliances, furniture, etc. shown on plans are to be supplied by owner. 15.No winter conditions are included. 16.Contract includes both on-site and in-office job coordination 17.Contractor will supply required insurances, including General Liability and Worker's Compensation 18.Use drop cloths and floor protection to protect flooring from front door to back porch. Replace as necessary. 19.Contractor to supply temporary sanitary facilities on site for workers' use 20.All work is limited to back porch unless otherwise noted 7" UP Division 8: Doors & Windows Doors 1.Remove & discard (2) doors per plan Windows 1.None Division 9: Finishes Wall And Ceiling Finishes 1.Remove & discard beadboard on existing half-walls 2.Remove & discard beadboard on porch ceiling Flooring 1.Remove & save decking for owner's reuse if possible Tile 1.None Interior Trim And Carpentry 1.Remove & discard casings at removed doors Divisions 10-14: Specialties, Equipment, Furnishings, Special Construction, Conveying Systems 1.None Division 15: Mechanical Plumbing 1.None Heating 1.None Division 16: Electrical 1.See Electrical Plan For Specifications NO WORKNO WORKNO WORKREMOVE & DISCARD 3/4"TRIM ON THESE WALLS Demo. Specifications Division 2: Site Work 1.None Division 3: Concrete 1.Selective demo will determine whether existing piers meet current code; if piers are found to be nonexistent or insufficient, cost to remove & discard will be extra to contract Divisions 4-5: Masonry, Metals 1.None Division 6: Wood & Plastics 1.Existing porch framing, including joists, beams, and roof framing, to remain; if framing is insufficient, cost to replace would be extra to contract 2.Remove & discard 2x4 porch half-walls 3.Remove & discard steps and landing facing driveway; piers are assumed to remain 4.Remove & discard 2x4 porch posts only; 4x4 posts to remain Division 7: Thermal & Moisture Protection Exterior Trim And Siding 1.Remove & discard 3/4" trim on exterior walls of back porch 2.Remove & discard all screening on back porch Insulation 1.None WINDOW SCHEDULE MANUFACTURER KEY LABEL FL.QTY.JAMB WIDTH HEIGHT R.O.DESCRIPTION EXT. FINISH INT. FINISH SCREEN GRILL TEMP.SASH LIMITER HARDWARE FINISH HEADER & JACK STUDS EGRESS MARVIN ELEVATE W01 ELGL 7260 E 1 2 4 9/16" FJP 5'-11 1/2"4'-11 3/4"6'-0 1/2" x 5'-0 1/4"LH GLIDER; LOW E WITH ARGON GLASS;STONE WHITE PRE-FINISHED WHITE Y N N N WHITE USE EXISTING BEAM Y WOOD ULTREX W02 ELGL 7260 E 1 1 4 9/16" FJP 5'-11 1/2"4'-11 3/4"6'-0 1/2" x 5'-0 1/4"LH GLIDER; LOW E WITH ARGON GLASS;STONE WHITE PRE-FINISHED WHITE Y N Y N WHITE USE EXISTING BEAM Y W03 ELCAP 2159 1 1 4 9/16" FJP 1'-8"4'-11 1/8"1'-9" x 4'-11 5/8"FIXED CASEMENT; LOW E WITH ARGON GLASS;STONE WHITE PRE-FINISHED WHITE N N Y N WHITE USE EXISTING BEAM N W04 ELGL 3660 1 1 4 9/16" FJP 2'-11 1/2"4'-11 3/4"3'-0 1/2" x 5'-0 1/4"LH GLIDER; LOW E WITH ARGON GLASS;STONE WHITE PRE-FINISHED WHITE Y N Y N WHITE USE EXISTING BEAM N TOTAL 5 DOOR SCHEDULE MANUFACTURER KEY LABEL FL.QTY.JAMB WIDTH HEIGHT R/O DESCRIPTION EXT. FINISH INT. FINISH SCREEN GRILL TEMP.HINGE FINISH HEADER & JACK STUDS HANDLE LOCK BORE THERMA-TRU (BY ALLOWANCE)D01 SMOOTH- STAR S118-LE 1 1 4 9/16" FJP 2'-10"6'-8"3'-0 1/2" X 6'-10 1/2" RH. FULL-LITE DOOR BY ALLOWANCE PAINT TBD.PAINT TBD.N N Y ZINC DICHROMATE USE EXISTING TBD BY ALLOWANCE KEYED DOUBLE THERMA-TRU (BY ALLOWANCE)D02 SMOOTH- STAR S118-LE 1 1 4 9/16" FJP 2'-8"6'-8"2'-10 1/2" X 6'-10 1/2" RH. FULL-LITE DOOR BY ALLOWANCE PAINT TBD.PAINT TBD.N N Y ZINC DICHROMATE USE EXISTING TBD BY ALLOWANCE KEYED DOUBLE TOTAL 2 WALL KEY= EXISTING 2x4 INTERIOR WALL= EXISTING 2x6 EXTERIOR WALL= EXISTING 2x4 HALF WALL= DEMO. 2x4 INTERIOR WALL= DEMO. 2x6 EXTERIOR WALL= DEMO 2x4 HALF WALL Division 6: Wood & Plastics Floor System 1.Existing floor joists are assumed to be 2x8 @ 16" O.C.; current code for living spaces can be met with 2x6s @ 16" O.C. If joists are found to be rotted or not meet code during demo, contractor will present homeowner with alternative options. 2.Placement of existing floor beam(s) and posts is unknown. It is assumed that no new beams or posts are required; cost to add would be extra to contract. 3.3/4" T&G Advantech subfloor 4.Supply & install 1/2" PT plywood at bottom of existing floor joists to hold in new insulation; nail on 2x2 ledgers and rip PT plywood to fit between joist bays from above Exterior Wall System 1.2x4 KD spruce exterior wall studs @ 16" O.C. 2.7/16" Zipwall sheathing, taped @ seams 3.The town is grandfathering the structure and is not enforcing the current code requirements. If the town decides to enforce this section of the code, contractor will discuss options with the owner. Additional work & costs would apply. Roof 1.Existing roof to remain Stairs and Landing 1.(2) 4x4 PT posts 2.(2) 2x6 PT drop girder 3.2x6 PT joists @ 16" O.C. 4.5/4" x 6" PT decking, picture framed and face screwed 5.Supply & install (3) 2x12 PT stringers 6.(3) treads @ 10 3/4" deep, 7" risers 7.Supply & install Brosco WM231 graspable handrail by allowance 8.Stair stringer to have primed pine fascia 9.Supply & install PT newel posts, balusters, and top and bottom rails to match existing as closely as possible, TBD by allowance 6 1/2" UP Division 9: Finishes Wall and Ceiling Finishes 1.Supply & install 1/2" standard drywall to all new wall framing and existing ceiling framing in sunroom 2.Apply (3) coats of joint compound & sand to smooth finish 3.Existing siding to remain on (2) walls in sunroom Flooring 1.Supply & install 2 1/4" strip red oak finish flooring to sunroom by allowance 2.Finish with (4) coats of water-based polyurethane floor finish; screened between coats Tile 1.None Interior Trim and Carpentry 1.Supply & install 6 3/8" primed pine baseboard with 1/2" quarter round in sunroom; profile to match existing 2.Supply & install 4 1/2" primed pine casings to new windows and doors; profile to match existing 3.Supply & install 1x2 primed pine trim where new drywall meets existing siding Painting 1.All painting & prep work is to be by owner Divisions 10-14: Specialties, Equipment, Furnishings, Special Construction, Conveying Systems 1.None Division 15: Mechanical Plumbing 1.None Heating 1.Supply & install Mitsubishi MUZ- FS09NA-U1 mini-split head in sunroom per plan Division 16: Electrical 1.See electrical plan for specifications 2' needed for top wall5' needed for right hand wall x 0.7 (roof height) x .95 (wall height) x 1.3 (braced wall lines)= 20 3/4" for top wall= 51 7/8" for right hand wall (double it for part that's under second floor)80" OPENING -> 32" SHEAR PANEL Division 7: Thermal & Moisture Protection Exterior Trim and Siding 1.Patch siding as needed with 1/2" x 6" CVG cedar clapboards, 2 5/8" reveal 2.Supply & install 1x6 Lifespan primed pine corner boards to sunroom 3.Supply & install 4 3/4" primed exterior window and door trim; 2" primed historic sill with 1" horn, no apron; and primed head casing including 3 1/2" flat and 2 1/4" crown, profile to match existing 4.Existing mud board, lattice, and trim is assumed to remain below sun room; if existing framing is found to be insufficient, lattice may need to be removed to modify framing. Removal and replacement work would be extra to contract. 5.Existing roof trim to remain 6.Supply & install 1x8 Lifespan primed pine fascia board on landing Roofing 1.Existing roofing to remain Insulation 1.Supply & install (3) layers of 2" foam board insulation to full depth of new floor cavity, R-30 2.Supply & install dense-pak cellulose to full depth of exterior wall cavity, R-13 3.Supply & install R-30 fiberglass batts in existing porch ceiling cavity 4.Fiberglass batts may not be able to meet code through entire roof, since current heel height is unknown. 5.Apply spray foam to framing gaps at new doors and windows 6.Disclaimer: HERS rating is not included; if required by town, cost will be extra to contract Division 8: Doors & Windows 1.Window and door headers per schedule; T.O.W. height to be 86" Doors 1.Supply & install (2) doors per plan and schedule TBD by allowance 2.Supply & install door hardware TBD by allowance Windows 1.Supply & install (5) Marvin Elevate windows per plan and scheduleMINI SPLITactually 3.5' needed for top wall -> comes out to 36''portal framing = 18" panels Specifications Division 2: Site Work 1.Call Dig Safe prior to start of construction 2.All landscaping within 10' of work area will be disturbed; survival of plants is not guaranteed 3.Any plants which are to be saved will be removed by owner prior to start of construction 4.No new landscaping is included Division 3: Concrete 1.Selective demo will determine whether existing piers meet current code; if piers are found to be nonexistent or insufficient, cost to supply & install new piers will be extra to contract Division 4: Masonry 1.None Division 5: Metals 1.Existing gutters and downspouts to remain NO WORKNO WORKNO WORKEXISTING SHEAR3/4" T&G ADVANTECH SUBFLOOR EXISTING JOISTS (2x8 ASSUMED) 2x2 LEDGERS 1/2" PT PLYWOOD 6" FOAM BOARD INSULATION, R-30 Development & Construction, Inc.110 Pulpit Hill RoadAmherst, Ma 01002413-549-7919 EMAIL: INFO@INTEGBUILD.COM© Integrity Development & Construction, Inc. (2023). All rights reserved.DESIGN BY NWFARLOW - WINNRESIDENCE2INTEGRITYA- SHEET: DATE: 2/16/2024CONTRACT &BUILDING PERMIT SET184 FEDERAL ST, FLORENCE, MA 01062PORCH FINISHING1 A-02 1 A-02 EXISTING FIRST FLOOR PLAN 1/4" = 1'-0" I NI TIA L HERE PRELIMINARY NOT FOR CONSTRUCTION DN TO REMAINTO REMAINTO REMAINTO REMAINTO REMAINTO REMAIN TO REMAIN TO REMAIN TO REMAIN TO REMAIN TO REMAIN TO REMAINREMOVE & SAVETO REMAINTO REMAINREMOVE & DISCARDTO REMAINTO REMAINTO REMAIN W03 T D01 W01 W01 W02 T D02W04DN 3 5/8"2'-8 7/8"3 1/2"3'-10"3 1/2"2'-8 1/4"4'4'-1 1/8"4'-10 5/8"6'-4 5/16"6'-4 5/16"3'-4 1/2"1'-11 1/8"3'-6 3/4"2'-4 1/8"6'-2 3/16"25'-0 7/8"7'-10"3 1/2"1'-10 7/8"3 1/2"3'-0 1/2"3 1/2"6'-1 1/8"3 1/2"6'-1 1/8"3 1/2"6'-1 1/4" 4'-1" WALL KEY = EXISTING 2x4 INTERIOR WALL = EXISTING 2x6 EXTERIOR WALL = EXISTING 2x4 HALF WALL = DEMO. 2x4 INTERIOR WALL = DEMO. 2x6 EXTERIOR WALL = DEMO 2x4 HALF WALL SUNROOM KITCHEN MUD ROOM CLOSET Division 6: Wood & Plastics Floor System 1.Existing floor joists are assumed to be 2x8 @ 16" O.C.; current code for living spaces can be met with 2x6s @ 16" O.C. If joists are found to be rotted or not meet code during demo, contractor will present homeowner with alternative options. 2.Placement of existing floor beam(s) and posts is unknown. It is assumed that no new beams or posts are required; cost to add would be extra to contract. 3.3/4" T&G Advantech subfloor 4.Supply & install 1/2" PT plywood at bottom of existing floor joists to hold in new insulation; nail on 2x2 ledgers and rip PT plywood to fit between joist bays from above Exterior Wall System 1.2x4 KD spruce exterior wall studs @ 16" O.C. 2.7/16" Zipwall sheathing, taped @ seams 3.The town is grandfathering the structure and is not enforcing the current code requirements. If the town decides to enforce this section of the code, contractor will discuss options with the owner. Additional work & costs would apply. Roof 1.Existing roof to remain Stairs and Landing 1.(2) 4x4 PT posts 2.(2) 2x6 PT drop girder 3.2x6 PT joists @ 16" O.C. 4.5/4" x 6" PT decking, picture framed and face screwed 5.Supply & install (3) 2x12 PT stringers 6.(3) treads @ 10 3/4" deep, 7" risers 7.Supply & install Brosco WM231 graspable handrail by allowance 8.Stair stringer to have primed pine fascia 9.Supply & install PT newel posts, balusters, and top and bottom rails to match existing as closely as possible, TBD by allowance 6 1/2" UP Division 9: Finishes Wall and Ceiling Finishes 1.Supply & install 1/2" standard drywall to all new wall framing and existing ceiling framing in sunroom 2.Apply (3) coats of joint compound & sand to smooth finish 3.Existing siding to remain on (2) walls in sunroom Flooring 1.Supply & install 2 1/4" strip red oak finish flooring to sunroom by allowance 2.Finish with (4) coats of water-based polyurethane floor finish; screened between coats Tile 1.None Interior Trim and Carpentry 1.Supply & install 6 3/8" primed pine baseboard with 1/2" quarter round in sunroom; profile to match existing 2.Supply & install 4 1/2" primed pine casings to new windows and doors; profile to match existing 3.Supply & install 1x2 primed pine trim where new drywall meets existing siding Painting 1.All painting & prep work is to be by owner Divisions 10-14: Specialties, Equipment, Furnishings, Special Construction, Conveying Systems 1.None Division 15: Mechanical Plumbing 1.None Heating 1.Supply & install Mitsubishi MUZ- FS09NA-U1 mini-split head in sunroom per plan Division 16: Electrical 1.See electrical plan for specifications 2' needed for top wall 5' needed for right hand wall x 0.7 (roof height) x .95 (wall height) x 1.3 (braced wall lines) = 20 3/4" for top wall = 51 7/8" for right hand wall (double it for part that's under second floor) 80" OPENING -> 32" SHEAR PANEL Division 7: Thermal & Moisture Protection Exterior Trim and Siding 1.Patch siding as needed with 1/2" x 6" CVG cedar clapboards, 2 5/8" reveal 2.Supply & install 1x6 Lifespan primed pine corner boards to sunroom 3.Supply & install 4 3/4" primed exterior window and door trim; 2" primed historic sill with 1" horn, no apron; and primed head casing including 3 1/2" flat and 2 1/4" crown, profile to match existing 4.Existing mud board, lattice, and trim is assumed to remain below sun room; if existing framing is found to be insufficient, lattice may need to be removed to modify framing. Removal and replacement work would be extra to contract. 5.Existing roof trim to remain 6.Supply & install 1x8 Lifespan primed pine fascia board on landing Roofing 1.Existing roofing to remain Insulation 1.Supply & install (3) layers of 2" foam board insulation to full depth of new floor cavity, R-30 2.Supply & install dense-pak cellulose to full depth of exterior wall cavity, R-13 3.Supply & install R-30 fiberglass batts in existing porch ceiling cavity 4.Fiberglass batts may not be able to meet code through entire roof, since current heel height is unknown. 5.Apply spray foam to framing gaps at new doors and windows 6.Disclaimer: HERS rating is not included; if required by town, cost will be extra to contract Division 8: Doors & Windows 1.Window and door headers per schedule; T.O.W. height to be 86" Doors 1.Supply & install (2) doors per plan and schedule TBD by allowance 2.Supply & install door hardware TBD by allowance Windows 1.Supply & install (5) Marvin Elevate windows per plan and scheduleMINI SPLITactually 3.5' needed for top wall -> comes out to 36'' portal framing = 18" panels Specifications Division 2: Site Work 1.Call Dig Safe prior to start of construction 2.All landscaping within 10' of work area will be disturbed; survival of plants is not guaranteed 3.Any plants which are to be saved will be removed by owner prior to start of construction 4.No new landscaping is included Division 3: Concrete 1.Selective demo will determine whether existing piers meet current code; if piers are found to be nonexistent or insufficient, cost to supply & install new piers will be extra to contract Division 4: Masonry 1.None Division 5: Metals 1.Existing gutters and downspouts to remain NO WORK NO WORK NO WORK LANDING EXISTING SHEAR1 A-5 1 A-5 2 A-5 2 A-5 3/4" T&G ADVANTECH SUBFLOOR EXISTING JOISTS (2x8 ASSUMED) 2x2 LEDGERS 1/2" PT PLYWOOD 6" FOAM BOARD INSULATION, R-30 110V Receptacles: Duplex, Weather Proof, GFCI Switches: Single Pole, Weather Proof, 3-Way, 4-Way Wall Jacks: CAT5, CAT5 + TV, TV/Cable Smoke Detectors: Ceiling Mounted, Wall Mounted Speakers: Ceiling Mounted, Wall Mounted WALL KEY= EXISTING 2x4 INTERIOR WALL= EXISTING 2x6 EXTERIOR WALL= EXISTING 2x4 HALF WALL= DEMO. 2x4 INTERIOR WALL= DEMO. 2x6 EXTERIOR WALL= DEMO 2x4 HALF WALL Division 6: Wood & Plastics Floor System 1.Existing floor joists are assumed to be 2x8 @ 16" O.C.; current code for living spaces can be met with 2x6s @ 16" O.C. If joists are found to be rotted or not meet code during demo, contractor will present homeowner with alternative options. 2.Placement of existing floor beam(s) and posts is unknown. It is assumed that no new beams or posts are required; cost to add would be extra to contract. 3.3/4" T&G Advantech subfloor 4.Supply & install 1/2" PT plywood at bottom of existing floor joists to hold in new insulation; nail on 2x2 ledgers and rip PT plywood to fit between joist bays from above Exterior Wall System 1.2x4 KD spruce exterior wall studs @ 16" O.C. 2.7/16" Zipwall sheathing, taped @ seams 3.The town is grandfathering the structure and is not enforcing the current code requirements. If the town decides to enforce this section of the code, contractor will discuss options with the owner. Additional work & costs would apply. Roof 1.Existing roof to remain Stairs and Landing 1.(2) 4x4 PT posts 2.(2) 2x6 PT drop girder 3.2x6 PT joists @ 16" O.C. 4.5/4" x 6" PT decking, picture framed and face screwed 5.Supply & install (3) 2x12 PT stringers 6.(3) treads @ 10 3/4" deep, 7" risers 7.Supply & install Brosco WM231 graspable handrail by allowance 8.Stair stringer to have primed pine fascia 9.Supply & install PT newel posts, balusters, and top and bottom rails to match existing as closely as possible, TBD by allowance 6 1/2" UP Division 9: Finishes Wall and Ceiling Finishes 1.Supply & install 1/2" standard drywall to all new wall framing and existing ceiling framing in sunroom 2.Apply (3) coats of joint compound & sand to smooth finish 3.Existing siding to remain on (2) walls in sunroom Flooring 1.Supply & install 2 1/4" strip red oak finish flooring to sunroom by allowance 2.Finish with (4) coats of water-based polyurethane floor finish; screened between coats Tile 1.None Interior Trim and Carpentry 1.Supply & install 6 3/8" primed pine baseboard with 1/2" quarter round in sunroom; profile to match existing 2.Supply & install 4 1/2" primed pine casings to new windows and doors; profile to match existing 3.Supply & install 1x2 primed pine trim where new drywall meets existing siding Painting 1.All painting & prep work is to be by owner Divisions 10-14: Specialties, Equipment, Furnishings, Special Construction, Conveying Systems 1.None Division 15: Mechanical Plumbing 1.None Heating 1.Supply & install Mitsubishi MUZ- FS09NA-U1 mini-split head in sunroom per plan Division 16: Electrical 1.See electrical plan for specifications 2' needed for top wall5' needed for right hand wall x 0.7 (roof height) x .95 (wall height) x 1.3 (braced wall lines)= 20 3/4" for top wall= 51 7/8" for right hand wall (double it for part that's under second floor)80" OPENING -> 32" SHEAR PANEL Division 7: Thermal & Moisture Protection Exterior Trim and Siding 1.Patch siding as needed with 1/2" x 6" CVG cedar clapboards, 2 5/8" reveal 2.Supply & install 1x6 Lifespan primed pine corner boards to sunroom 3.Supply & install 4 3/4" primed exterior window and door trim; 2" primed historic sill with 1" horn, no apron; and primed head casing including 3 1/2" flat and 2 1/4" crown, profile to match existing 4.Existing mud board, lattice, and trim is assumed to remain below sun room; if existing framing is found to be insufficient, lattice may need to be removed to modify framing. Removal and replacement work would be extra to contract. 5.Existing roof trim to remain 6.Supply & install 1x8 Lifespan primed pine fascia board on landing Roofing 1.Existing roofing to remain Insulation 1.Supply & install (3) layers of 2" foam board insulation to full depth of new floor cavity, R-30 2.Supply & install dense-pak cellulose to full depth of exterior wall cavity, R-13 3.Supply & install R-30 fiberglass batts in existing porch ceiling cavity 4.Fiberglass batts may not be able to meet code through entire roof, since current heel height is unknown. 5.Apply spray foam to framing gaps at new doors and windows 6.Disclaimer: HERS rating is not included; if required by town, cost will be extra to contract Division 8: Doors & Windows 1.Window and door headers per schedule; T.O.W. height to be 86" Doors 1.Supply & install (2) doors per plan and schedule TBD by allowance 2.Supply & install door hardware TBD by allowance Windows 1.Supply & install (5) Marvin Elevate windows per plan and scheduleMINI SPLITactually 3.5' needed for top wall -> comes out to 36''portal framing = 18" panels Specifications Division 2: Site Work 1.Call Dig Safe prior to start of construction 2.All landscaping within 10' of work area will be disturbed; survival of plants is not guaranteed 3.Any plants which are to be saved will be removed by owner prior to start of construction 4.No new landscaping is included Division 3: Concrete 1.Selective demo will determine whether existing piers meet current code; if piers are found to be nonexistent or insufficient, cost to supply & install new piers will be extra to contract Division 4: Masonry 1.None Division 5: Metals 1.Existing gutters and downspouts to remain NO WORKNO WORKNO WORK EXISTING SHEAR3/4" T&G ADVANTECH SUBFLOOR EXISTING JOISTS (2x8 ASSUMED) 2x2 LEDGERS 1/2" PT PLYWOOD 6" FOAM BOARD INSULATION, R-30Development & Construction, Inc.110 Pulpit Hill RoadAmherst, Ma 01002413-549-7919 EMAIL: INFO@INTEGBUILD.COM© Integrity Development & Construction, Inc. (2023). All rights reserved.DESIGN BY NWFARLOW - WINNRESIDENCE3INTEGRITYA- SHEET: DATE: 2/16/2024CONTRACT &BUILDING PERMIT SET184 FEDERAL ST, FLORENCE, MA 01062PORCH FINISHING1 A-03 1 A-03 PROPOSED FIRST FLOOR PLAN 1/4" = 1'-0" I NI TIA L HERE PRELIMINARY NOT FOR CONSTRUCTION D02 W04 D02 W04 EXISTING PIERS, POSTS, GIRDERS, AND FLOOR JOISTS TO REMAIN 2 5/8" REVEAL CLAPBOARD, SIDING, SPECIES TBD 7/16" ZIPWALL SHEATHING, TAPED @ SEAMS 2x4 KD SPRUCE EXTERIOR WALL STUDS @ 16" O.C. DENSE-PAK CELLULOSE, R-13 1/2" STANDARD DRYWALL EXISTING ROOF TO REMAIN R-30 FIBERGLASS BATTS IN EXISTING CEILING CAVITY EXISTING MUD BOARD, LATTICE, AND TRIM TO REMAIN 4 3/4" PRIMED EXTERIOR WINDOW AND DOOR TRIM; 2" PRIMED HISTORIC SILL WITH 1" HORN, NO APRON; AND PRIMED HEAD CASING INCLUDING 3 1/2" FLAT AND 2 1/4" CROWN, PROFILE TO MATCH EXISTING (3) LAYERS OF 2" FOAM BOARD INSULATION, R-30 1/2" PT PLYWOOD TO HOLD IN NEW INSULATION; NAIL ON 2x2 LEDGERS AND RIP PT TO FIT BETWEEN JOIST BAYS 2 1/4" STRIP RED OAK FINISH FLOORING BY ALLOWANCE 6 3/8" PRIMED PINE BASEBOARD WITH 1/2" QUARTER ROUND, PROFILE TO MATCH EXISTING 4 1/2" PRIMED PINE CASINGS, PROFILE TO MATCH EXISTING D02 W04 D02 W04 4x4 PT POSTS (2) 2x6 PT DROP GIRDER 5/4" x 6" PT DECKING, PICTURE FRAMED AND FACE SCREWED 2x12 PT STRINGERS 10 3/4" DEEP TREADS 7" PRIMED PINE RISERS BROSCO WM231 GRASPABLE HANDRAIL EXISTING PIERS TO REMAIN PT NEWEL POSTS BALUSTERS, AND TOP AND BOTTOM RAILS TO MATCH EXISTING AS CLOSELY AS POSSIBLE BY ALLOWANCE 2x6 PT JOISTS @ 16" O.C. 1x8 LIFESPAN PRIMED PINE DECK FASCIA BOARD EXISTING PIERS TO REMAIN; NEW 4x4 PT POSTS 2x6 PT JOISTS @ 16" O.C. (2) 2x6 PT DROP GIRDER W03 T D01 W01 5/4" x 6" PT DECKING WALL KEY= EXISTING 2x4 INTERIOR WALL= EXISTING 2x6 EXTERIOR WALL= EXISTING 2x4 HALF WALL= DEMO. 2x4 INTERIOR WALL= DEMO. 2x6 EXTERIOR WALL= DEMO 2x4 HALF WALLDivision 6: Wood &Plastics Floor System1.Existing floor joists areassumed to be 2x8 @ 16"O.C.; current code forliving spaces can be metwith 2x6s @ 16" O.C. Ifjoists are found to berotted or not meet codeduring demo, contractorwill present homeownerwith alternative options.2.Placement of existingfloor beam(s) and postsis unknown. It is assumedthat no new beams orposts are required; costto add would be extra tocontract.3.3/4" T&G Advantechsubfloor4.Supply & install 1/2" PTplywood at bottom ofexisting floor joists to holdin new insulation; nail on2x2 ledgers and rip PTplywood to fit betweenjoist bays from aboveExterior Wall System1.2x4 KD spruce exteriorwall studs @ 16" O.C.2.7/16" Zipwall sheathing,taped @ seams3.The town isgrandfathering thestructure and is notenforcing the currentcode requirements. If thetown decides to enforcethis section of the code, contractor will discuss options with the owner. Additional work & costs would apply. Roof 1.Existing roof to remain Stairs and Landing 1.(2) 4x4 PT posts 2.(2) 2x6 PT drop girder 3.2x6 PT joists @ 16" O.C. 4.5/4" x 6" PT decking, picture framed and face screwed 5.Supply & install (3) 2x12 PT stringers 6.(3) treads @ 10 3/4" deep, 7" risers 7.Supply & install Brosco WM231 graspable handrail by allowance 8.Stair stringer to have primed pine fascia 9.Supply & install PT newel posts, balusters, and top and bottom rails to match existing as closely as possible, TBD by allowance 6 1/2" UPDivision 9: Finishes Wall and CeilingFinishes1.Supply & install 1/2"standard drywall to allnew wall framing andexisting ceiling framingin sunroom2.Apply (3) coats of jointcompound & sand tosmooth finish3.Existing siding to remainon (2) walls in sunroomFlooring1.Supply & install 2 1/4"strip red oak finishflooring to sunroom byallowance2.Finish with (4) coats ofwater-basedpolyurethane floor finish;screened between coatsTile1.NoneInterior Trim andCarpentry1.Supply & install 6 3/8"primed pine baseboardwith 1/2" quarter roundin sunroom; profile tomatch existing2.Supply & install 4 1/2"primed pine casings tonew windows and doors;profile to match existing3.Supply & install 1x2primed pine trim wherenew drywall meetsexisting sidingPainting 1.All painting & prep work is to be by owner Divisions 10-14: Specialties, Equipment, Furnishings, Special Construction, Conveying Systems 1.None Division 15: Mechanical Plumbing 1.None Heating 1.Supply & install Mitsubishi MUZ- FS09NA-U1 mini-split head in sunroom per plan Division 16: Electrical 1.See electrical plan for specifications 2' needed for top wall5' needed for right hand wall x 0.7 (roof height) x .95 (wall height) x 1.3 (braced wall lines)= 20 3/4" for top wall= 51 7/8" for right hand wall (double it for part that's under second floor)80" OPENING -> 32" SHEAR PANELDivision 7: Thermal &Moisture Protection Exterior Trim and Siding1.Patch siding as needed with1/2" x 6" CVG cedarclapboards, 2 5/8" reveal2.Supply & install 1x6 Lifespanprimed pine corner boards tosunroom3.Supply & install 4 3/4"primed exterior window anddoor trim; 2" primed historicsill with 1" horn, no apron;and primed head casingincluding 3 1/2" flat and 21/4" crown, profile to matchexisting4.Existing mud board, lattice,and trim is assumed toremain below sun room; ifexisting framing is found tobe insufficient, lattice mayneed to be removed tomodify framing. Removaland replacement work wouldbe extra to contract.5.Existing roof trim to remain6.Supply & install 1x8 Lifespanprimed pine fascia board onlandingRoofing1.Existing roofing to remainInsulation1.Supply & install (3) layers of2" foam board insulation tofull depth of new floor cavity,R-302.Supply & install dense-pakcellulose to full depth ofexterior wall cavity, R-133.Supply & install R-30 fiberglass batts in existing porch ceiling cavity 4.Fiberglass batts may not be able to meet code through entire roof, since current heel height is unknown. 5.Apply spray foam to framing gaps at new doors and windows 6.Disclaimer: HERS rating is not included; if required by town, cost will be extra to contract Division 8: Doors & Windows 1.Window and door headers per schedule; T.O.W. height to be 86" Doors 1.Supply & install (2) doors per plan and schedule TBD by allowance 2.Supply & install door hardware TBD by allowance Windows 1.Supply & install (5) Marvin Elevate windows per plan and scheduleMINI SPLITactually 3.5' needed for top wall -> comes out to 36''portal framing = 18" panelsSpecificationsDivision 2: SiteWork 1.Call Dig Safeprior to start ofconstruction2.All landscapingwithin 10' ofwork area willbe disturbed;survival ofplants is notguaranteed3.Any plantswhich are to besaved will beremoved byowner prior tostart ofconstruction4.No newlandscaping isincludedDivision 3:Concrete 1.Selective demowill determinewhetherexisting piersmeet currentcode; if piersare found to benonexistent orinsufficient, costto supply &install new pierswill be extra tocontractDivision 4:Masonry 1.None Division 5: Metals 1.Existing gutters and downspouts to remain NO WORKNO WORKNO WORKEXISTING SHEAR3/4" T&G ADVANTECH SUBFLOOR EXISTING JOISTS (2x8 ASSUMED) 2x2 LEDGERS 1/2" PT PLYWOOD 6" FOAM BOARD INSULATION, R-30 Development & Construction, Inc.110 Pulpit Hill RoadAmherst, Ma 01002413-549-7919 EMAIL: INFO@INTEGBUILD.COM© Integrity Development & Construction, Inc. (2023). All rights reserved.DESIGN BY NWFARLOW - WINNRESIDENCE4INTEGRITYA- SHEET: DATE: 2/16/2024CONTRACT &BUILDING PERMIT SET184 FEDERAL ST, FLORENCE, MA 01062PORCH FINISHING1 A-04 1 A-04 PROPOSED SECTION 1/2" = 1'-0" I NI TIA L HERE 5 A-04 5 A-04 PROPOSED STAIR AND LANDING SECTION 1/2" = 1'-0" 4 A-04 4 A-04 PROPOSED LANDING DECKING PLAN 1/2" = 1'-0" 2 A-04 2 A-04 PROPOSED LANDING FRAMING PLAN 1/2" = 1'-0" 3 A-04 3 A-04 PROPOSED JOIST BAY DETAIL 1" = 1'-0" PRELIMINARY NOT FOR CONSTRUCTION W01W01W01W01 TO REMAINTO REMAIN TO REMAIN W03 T D01 W01W01W02 T TO REMAINTO REMAIN W03 T D01 W01W01W02 T W01W01W01W01W01W01W01 TO REMAINTO REMAIN TO REMAIN W03 T D01 W01W01W02 T TO REMAINTO REMAIN W03 T D01 W01W01W02 T W01W01W01 D02 W04 D02 W04 D02 W04 D02 W04 Development & Construction, Inc.110 Pulpit Hill RoadAmherst, Ma 01002413-549-7919 EMAIL: INFO@INTEGBUILD.COM© Integrity Development & Construction, Inc. (2023). All rights reserved.DESIGN BY NWFARLOW - WINNRESIDENCE5INTEGRITYA- SHEET: DATE: 2/16/2024CONTRACT &BUILDING PERMIT SET184 FEDERAL ST, FLORENCE, MA 01062PORCH FINISHINGI NI TIA L HERE 1 A-05 1 A-05 PROPOSED ELEVATION 3/8" = 1'-0" 2 A-05 2 A-05 PROPOSED ELEVATION 3/8" = 1'-0" PRELIMINARY NOT FOR CONSTRUCTION DN TO REMAINTO REMAINTO REMAINTO REMAINTO REMAINTO REMAIN TO REMAIN TO REMAIN TO REMAIN TO REMAIN TO REMAIN TO REMAINREMOVE & SAVETO REMAINTO REMAINREMOVE & DISCARDTO REMAINTO REMAINTO REMAIN REMOVE & DISCARD REMOVE & DISCARDDN 3 T 3 R R WPWP WP WP Division 16: Electrical Demo. 1.All electrical to remain in existing locations unless otherwise specified 2.No work to existing house smoke/CO system included 3.All electrical work is included by allowance 4.Remove & save (2) ceiling fans per plan 5.Remove & discard (1) ceiling light per plan 6.Remove & discard (1) doorbell 7.Remove & discard (1) WP switch per plan 8.Remove & discard (3) WP outlets BACK PORCH KITCHEN MUD ROOM CLOSET ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETRETR ETR TO BASEMENT ETR ETR ETR ETR ETRREMOVE & DISCARD ETR ETR REMOVE & SAVEREMOVE & DISCARD REMOVE & SAVE REMOVE & DISCARD REMOVE & DISCARD REMOVE & DISCARD Division 16: Electrical Demo. 1.All electrical to remain in existing locations unless otherwise specified 2.No work to existing house smoke/CO system included 3.All electrical work is included by allowance 4.Remove & save (2) ceiling fans per plan 5.Remove & discard (1) ceiling light per plan 6.Remove & discard (1) doorbell 7.Remove & discard (1) WP switch per plan 8.Remove & discard (3) WP outlets ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETRETR ETR TO BASEMENT ETR ETR ETR ETRETRREMOVE & DISCARD ETR ETR REMOVE & SAVEREMOVE & DISCARD REMOVE & SAVE REMOVE & DISCARD REMOVE & DISCARD REMOVE & DISCARD DN TO REMAINTO REMAINTO REMAINTO REMAINTO REMAINTO REMAIN TO REMAIN TO REMAIN TO REMAIN TO REMAIN TO REMAIN TO REMAINREMOVE & SAVETO REMAINTO REMAINREMOVE & DISCARDTO REMAINTO REMAINTO REMAIN W03 T D01 W01 W01 W02 T D02W04DN 3 T 3 R R T 4 4 4 Division 16: Electrical 1.All electrical to remain in existing locations unless otherwise specified 2.All new electrical device locations to be confirmed w/ owner in field; Cost of changes will be additional to contract 3.All electrical work is included by allowance 4.No work to existing house smoke/CO system included 5.All switches to be toggle style; Color white / ivory 6.All outlets to be duplex style; Color white/ivory 7.Wire outlets to code 8.Reinstall (2) saved ceiling fans in existing locations on existing switching 9.Supply & install (1) new ceiling light in existing location on (3) new fourway switches, (1) in existing switch location; fixture TBD by allowance 10.Supply & install electric baseboard heat in sunroom 11.Wire (3) new outlets where WP outlets have been removed 12.Wire for mini split SUNROOM KITCHEN MUD ROOM CLOSET ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETRETR ETR TO BASEMENT ETR ETR ETR ETR ETRNEW NEW NEW ETR ETR NEW NEW NEW NEW NEW NEW NEW REINSTALL SAVED REINSTALL SAVED LANDING Division 16: Electrical 1.All electrical to remain in existing locations unless otherwise specified 2.All new electrical device locations to be confirmed w/ owner in field; Cost of changes will be additional to contract 3.All electrical work is included by allowance 4.No work to existing house smoke/CO system included 5.All switches to be toggle style; Color white / ivory 6.All outlets to be duplex style; Color white/ivory 7.Wire outlets to code 8.Reinstall (2) saved ceiling fans in existing locations on existing switching 9.Supply & install (1) new ceiling light in existing location on (3) new fourway switches, (1) in existing switch location; fixture TBD by allowance 10.Supply & install electric baseboard heat in sunroom 11.Wire (3) new outlets where WP outlets have been removed 12.Wire for mini split ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETRETR ETR TO BASEMENT ETR ETR ETR ETRETRNEW NEW NEW ETR ETR NEW NEW NEW NEWNEW NEW NEW REINSTALL SAVED REINSTALL SAVED Development & Construction, Inc.110 Pulpit Hill RoadAmherst, Ma 01002413-549-7919 EMAIL: INFO@INTEGBUILD.COM© Integrity Development & Construction, Inc. (2023). All rights reserved.DESIGN BY NWFARLOW - WINNRESIDENCE6INTEGRITYA- SHEET: DATE: 2/16/2024CONTRACT &BUILDING PERMIT SET184 FEDERAL ST, FLORENCE, MA 01062PORCH FINISHINGEXISTING ELECTRICAL PLAN 1/4" = 1'-0" 1 E-01 1 E-01 I NI TIA L HERE E-1 PROPOSED ELECTRICAL PLAN 1/4" = 1'-0" 2 E-01 2 E-01