Parent - Northampton MECH rev1 2024-1-2AERIAL MAP
NOT TO SCALEA SITE PLAN
NOT TO SCALEB
MAIN LOAD CENTER
MAIN SERVICE DISCONNECT
SOLAR PV EQUIPMNENT
(BASEMENT)
PROJECT INFORMATION:
Project:Parent
Northampton
Client:Kevin Parent
Maude
Address:40 Berkshire Terrace
Northampton, MA 01062
SYSTEM DETAILS
Total System Size:4.2 kW - DC SOLAR
3.8 kW - AC SOLAR
Modules:(10) Hanwha Q Cell 420 BLK Q TRON M-G2+
Optimizers:(10) SolarEdge S440
Alt. Optimizers:[Alt.Opti, P505, S440, S500, S440, S500B]
Inverters:(1) SolarEdge 3.8kW HD-Wave w/ RGM
DESIGN CRITERIA
Ground Snow Load:40 (psf)
Design Wind Speed:117 (mph)
Exposure Category B
Risk Category:II
AUTHORITY HAVING JURISDICTION
Building:Kevin Ross (413) 587-1239
Fire:Natalie Stollmeyer (413) 587-1241
Electrical:Roger Malo (413) 587-1244
Electrical Utility:National Grid
Code Ref:2023 NEC
PROJECT NOTES
311 WELLS STREET, SUITE B
GREENFIELD, MA 01301
WWW.PVSQUARED.COOP
413-772-8788
SIZE:
PV SQUARED SOLAR
SCALE:
DATE:
BY:
REV:
PROJECT:
CLIENT:
SITE:
PARENT
NORTHAMPTON
KEVIN PARENT
MAUDE WILLIAMSON
40 BERKSHIRE TERRACE
NORTHAMPTON, MA 01062
1
1/2/2024
ROBIN CREAMER
SITE PLAN &
PROJECT INFO.
NO SCALE
11x17
PV-M1
FIRE ACCESS PATHWAYS
MIN. 36" WIDE GUTTER TO RIDGE
MIN. 18" BOTH SIDES OF RIDGE
FIRE CODE COMPLIANCE
TOTAL ROOF AREA: 867 SQ FT
TOTAL SOLAR AREA: 210 SQ FT
SOLAR COVERAGE: 24%
ROOF PITCH: 29°
NO ESS
UTILITY SERVICE METER
UTILITY SOLAR DISCONNECT
(OUTSIDE)
SOLAR ARRAY
(GARAGE ROOF)
SOLAR DC DISCONNECT
NOT RAPID SHUTDOWN
(OUTSIDE)
OVERHANG ARRAY AS NEEDED (MAX. 6")
AT ROOF PITCH CHANGE TO ALLOW FOR
18" FIRE SETBACK AT RIDGE
(17') 102"(17') 16913
16"
(17') 102"(17') 172 5
16"
Array 272 5
16"
Roof 33315
16"Roof 12634"Array 1121516"9"71"110"59"3
4"
5"
1 3
16"
113
4"
57
8"
445
8"
6713
16"
MODULE DETAIL
SCALE: 1/4" = 1'A
ARRAY LAYOUT
SCALE: 1/4" = 1'B
311 WELLS STREET, SUITE B
GREENFIELD, MA 01301
WWW.PVSQUARED.COOP
413-772-8788
SIZE:
PV SQUARED SOLAR
SCALE:
DATE:
BY:
REV:
PROJECT:
CLIENT:
SITE:
PARENT
NORTHAMPTON
KEVIN PARENT
MAUDE WILLIAMSON
40 BERKSHIRE TERRACE
NORTHAMPTON, MA 01062
1
1/2/2024
ROBIN CREAMER
ARRAY LAYOUT
& ROOF DATA
AS SHOWN
11x17
PV-M2
ROOF SPECIFICATIONS
Material:Composite Shingles
Attachment Structure:Decking/Rafters
pitch:29°
Azimuth:195°
MODULE SPECIFICATIONS
MODULE MODEL:Hanwha Q Cell 420 BLK Q TRON M-G2+ / Q.Tron BLK M-G2+
420
Dimensions:67.8" x 44.65" x 30mm
Clamp Long Side:5 7/8"-11 3/4"
Clamp Short Side:3/4"-5"
RAIL SPECIFICATIONS
Make & Model:XR10 / XR100
Clamp Torque:80 in-lbs
L-Foot Torque:250 in-lbs
Max Cantilever:24"
ATTACHMENT SPECIFICATIONS
Bases/Flashing:IronRidge Halo Ultra Grip
Alternate Bases/Flashing:Sunmodo Nanomount
Fasteners:#14-10 x 2" Type A MP (Decking Screws)
Alternate Fasteners:#14-10 x 3" Type A MP (Rafter Screws)
Sealant:CHEMLINK M-1
Max. Spacing:54" USE 48" TYP.
ARRAY NOTES
Framing and attachment locations to be verified on site.
Bases are staggered to distribute point loading except at edges of array.
Additional or alternative bases may be used to meet actual roof conditions.
Ironridge Rail Gap Spacing: (3/8" Horizontal Spacing, 1/2" Vertical Spacing)
OVERHANG ARRAY AS NEEDED (MAX. 6")
AT ROOF PITCH CHANGE TO ALLOW FOR
18" FIRE SETBACK AT RIDGE
ROOF ATTACHMENTS
INSTALL ON DECKING
48" OC TYP.
RAFTERS 24" OC
PLYWOOD DECKING
NOTE:
OVERHANG ARRAY AS NEEDED AT ROOF PITCH
CHANGE TO ALLOW FOR 18" FIRE SETBACK AT RIDGE
ANIMAL GUARD AROUND ARRAY PERIMETER
PLEASE TRACK TIME SPENT ON ANIMAL GUARD AND
REPORT TO SERVICE DEPT.
RAIL
311 WELLS STREET, SUITE B
GREENFIELD, MA 01301
WWW.PVSQUARED.COOP
413-772-8788
SIZE:
PV SQUARED SOLAR
SCALE:
DATE:
BY:
REV:
PROJECT:
CLIENT:
SITE:
PARENT
NORTHAMPTON
KEVIN PARENT
MAUDE WILLIAMSON
40 BERKSHIRE TERRACE
NORTHAMPTON, MA 01062
1
1/2/2024
ROBIN CREAMER
MODULE MAP
NO SCALE
11x17
PV-M4
PLAQUE NOTES:
·RED BACKGROUND WITH WHITE TEXT AND LINES
·ADHESIVE ON BACK OF PLAQUE
·NUMBER NEEDED: 4
WARNING
MULTIPLE SOURCES OF POWER
WITH DISCONNECTS LOCATED AS SHOWN:
FOR SERVICE AND OPERATION OF
SOLAR PV SYSTEM CONTACT
PV SQUARED (413) 772-8788
5"6"DESIGN NOTES: (VERSION 2022-2-6)
1.SET PLAQUE TEXT TO. PV ONLY / PV & ESS / ESS ONLY
2.PLAQUE MUST BE SINGLE COLOR EXCEPT RED CUT LINE
3.SAVE AS SINGLE PAGE PDF (GENERAL SETTINGS)
LAYERS
·PV_L-BLOCK (PLAQUE BLOCK)
·PV_L-CUT-LINE (RED LINE, EDGE OF PLAQUE)
·PV_L-PLAQUE-LINES (VISIBLE LINES AND ELEMENTS)
·PV_L-TEXT (ALL TEXT & LEADERS)
·PV_L-PLAQUE-LINES (VISIBLE ENGRAVED LINES)
·PV_G-LOGO (LOGO)
TO WORK ON:
·RED CUT LINE SHOULD BE .003 PTS (CAN BE CHANGED BY ENGRAVER)
·SEE IF WE CAN MAKE THE TEXT VECTOR OBJECTS?
·LOGO - CURRENTLY IS A PICTURE- SEE IF WE CAN CHANGE SETTINGS
TO MAKE THE VECTOR COPY WORK
311 WELLS STREET, SUITE B
GREENFIELD, MA 01301
WWW.PVSQUARED.COOP
413-772-8788
SIZE:
PV SQUARED SOLAR
SCALE:
DATE:
BY:
REV:
PROJECT:
CLIENT:
SITE:
PARENT
NORTHAMPTON
KEVIN PARENT
MAUDE WILLIAMSON
40 BERKSHIRE TERRACE
NORTHAMPTON, MA 01062
1
1/2/2024
ROBIN CREAMER
SITE PLAQUE
NO SCALE
11x17
PV-P1
MAIN LOAD CENTER
MAIN SERVICE DISCONNECT
SOLAR PV EQUIPMNENT
(BASEMENT)
UTILITY SERVICE METER
UTILITY SOLAR DISCONNECT
(OUTSIDE)
SOLAR ARRAY
(GARAGE ROOF)
SOLAR DC DISCONNECT
NOT RAPID SHUTDOWN
(OUTSIDE)