Parent - Northampton MECH rev1 2024-1-2AERIAL MAP NOT TO SCALEA SITE PLAN NOT TO SCALEB MAIN LOAD CENTER MAIN SERVICE DISCONNECT SOLAR PV EQUIPMNENT (BASEMENT) PROJECT INFORMATION: Project:Parent Northampton Client:Kevin Parent Maude Address:40 Berkshire Terrace Northampton, MA 01062 SYSTEM DETAILS Total System Size:4.2 kW - DC SOLAR 3.8 kW - AC SOLAR Modules:(10) Hanwha Q Cell 420 BLK Q TRON M-G2+ Optimizers:(10) SolarEdge S440 Alt. Optimizers:[Alt.Opti, P505, S440, S500, S440, S500B] Inverters:(1) SolarEdge 3.8kW HD-Wave w/ RGM DESIGN CRITERIA Ground Snow Load:40 (psf) Design Wind Speed:117 (mph) Exposure Category B Risk Category:II AUTHORITY HAVING JURISDICTION Building:Kevin Ross (413) 587-1239 Fire:Natalie Stollmeyer (413) 587-1241 Electrical:Roger Malo (413) 587-1244 Electrical Utility:National Grid Code Ref:2023 NEC PROJECT NOTES 311 WELLS STREET, SUITE B GREENFIELD, MA 01301 WWW.PVSQUARED.COOP 413-772-8788 SIZE: PV SQUARED SOLAR SCALE: DATE: BY: REV: PROJECT: CLIENT: SITE: PARENT NORTHAMPTON KEVIN PARENT MAUDE WILLIAMSON 40 BERKSHIRE TERRACE NORTHAMPTON, MA 01062 1 1/2/2024 ROBIN CREAMER SITE PLAN & PROJECT INFO. NO SCALE 11x17 PV-M1 FIRE ACCESS PATHWAYS MIN. 36" WIDE GUTTER TO RIDGE MIN. 18" BOTH SIDES OF RIDGE FIRE CODE COMPLIANCE TOTAL ROOF AREA: 867 SQ FT TOTAL SOLAR AREA: 210 SQ FT SOLAR COVERAGE: 24% ROOF PITCH: 29° NO ESS UTILITY SERVICE METER UTILITY SOLAR DISCONNECT (OUTSIDE) SOLAR ARRAY (GARAGE ROOF) SOLAR DC DISCONNECT NOT RAPID SHUTDOWN (OUTSIDE) OVERHANG ARRAY AS NEEDED (MAX. 6") AT ROOF PITCH CHANGE TO ALLOW FOR 18" FIRE SETBACK AT RIDGE (17') 102"(17') 16913 16" (17') 102"(17') 172 5 16" Array 272 5 16" Roof 33315 16"Roof 12634"Array 1121516"9"71"110"59"3 4" 5" 1 3 16" 113 4" 57 8" 445 8" 6713 16" MODULE DETAIL SCALE: 1/4" = 1'A ARRAY LAYOUT SCALE: 1/4" = 1'B 311 WELLS STREET, SUITE B GREENFIELD, MA 01301 WWW.PVSQUARED.COOP 413-772-8788 SIZE: PV SQUARED SOLAR SCALE: DATE: BY: REV: PROJECT: CLIENT: SITE: PARENT NORTHAMPTON KEVIN PARENT MAUDE WILLIAMSON 40 BERKSHIRE TERRACE NORTHAMPTON, MA 01062 1 1/2/2024 ROBIN CREAMER ARRAY LAYOUT & ROOF DATA AS SHOWN 11x17 PV-M2 ROOF SPECIFICATIONS Material:Composite Shingles Attachment Structure:Decking/Rafters pitch:29° Azimuth:195° MODULE SPECIFICATIONS MODULE MODEL:Hanwha Q Cell 420 BLK Q TRON M-G2+ / Q.Tron BLK M-G2+ 420 Dimensions:67.8" x 44.65" x 30mm Clamp Long Side:5 7/8"-11 3/4" Clamp Short Side:3/4"-5" RAIL SPECIFICATIONS Make & Model:XR10 / XR100 Clamp Torque:80 in-lbs L-Foot Torque:250 in-lbs Max Cantilever:24" ATTACHMENT SPECIFICATIONS Bases/Flashing:IronRidge Halo Ultra Grip Alternate Bases/Flashing:Sunmodo Nanomount Fasteners:#14-10 x 2" Type A MP (Decking Screws) Alternate Fasteners:#14-10 x 3" Type A MP (Rafter Screws) Sealant:CHEMLINK M-1 Max. Spacing:54" USE 48" TYP. ARRAY NOTES Framing and attachment locations to be verified on site. Bases are staggered to distribute point loading except at edges of array. Additional or alternative bases may be used to meet actual roof conditions. Ironridge Rail Gap Spacing: (3/8" Horizontal Spacing, 1/2" Vertical Spacing) OVERHANG ARRAY AS NEEDED (MAX. 6") AT ROOF PITCH CHANGE TO ALLOW FOR 18" FIRE SETBACK AT RIDGE ROOF ATTACHMENTS INSTALL ON DECKING 48" OC TYP. RAFTERS 24" OC PLYWOOD DECKING NOTE: OVERHANG ARRAY AS NEEDED AT ROOF PITCH CHANGE TO ALLOW FOR 18" FIRE SETBACK AT RIDGE ANIMAL GUARD AROUND ARRAY PERIMETER PLEASE TRACK TIME SPENT ON ANIMAL GUARD AND REPORT TO SERVICE DEPT. RAIL 311 WELLS STREET, SUITE B GREENFIELD, MA 01301 WWW.PVSQUARED.COOP 413-772-8788 SIZE: PV SQUARED SOLAR SCALE: DATE: BY: REV: PROJECT: CLIENT: SITE: PARENT NORTHAMPTON KEVIN PARENT MAUDE WILLIAMSON 40 BERKSHIRE TERRACE NORTHAMPTON, MA 01062 1 1/2/2024 ROBIN CREAMER MODULE MAP NO SCALE 11x17 PV-M4 PLAQUE NOTES: ·RED BACKGROUND WITH WHITE TEXT AND LINES ·ADHESIVE ON BACK OF PLAQUE ·NUMBER NEEDED: 4 WARNING MULTIPLE SOURCES OF POWER WITH DISCONNECTS LOCATED AS SHOWN: FOR SERVICE AND OPERATION OF SOLAR PV SYSTEM CONTACT PV SQUARED (413) 772-8788 5"6"DESIGN NOTES: (VERSION 2022-2-6) 1.SET PLAQUE TEXT TO. PV ONLY / PV & ESS / ESS ONLY 2.PLAQUE MUST BE SINGLE COLOR EXCEPT RED CUT LINE 3.SAVE AS SINGLE PAGE PDF (GENERAL SETTINGS) LAYERS ·PV_L-BLOCK (PLAQUE BLOCK) ·PV_L-CUT-LINE (RED LINE, EDGE OF PLAQUE) ·PV_L-PLAQUE-LINES (VISIBLE LINES AND ELEMENTS) ·PV_L-TEXT (ALL TEXT & LEADERS) ·PV_L-PLAQUE-LINES (VISIBLE ENGRAVED LINES) ·PV_G-LOGO (LOGO) TO WORK ON: ·RED CUT LINE SHOULD BE .003 PTS (CAN BE CHANGED BY ENGRAVER) ·SEE IF WE CAN MAKE THE TEXT VECTOR OBJECTS? ·LOGO - CURRENTLY IS A PICTURE- SEE IF WE CAN CHANGE SETTINGS TO MAKE THE VECTOR COPY WORK 311 WELLS STREET, SUITE B GREENFIELD, MA 01301 WWW.PVSQUARED.COOP 413-772-8788 SIZE: PV SQUARED SOLAR SCALE: DATE: BY: REV: PROJECT: CLIENT: SITE: PARENT NORTHAMPTON KEVIN PARENT MAUDE WILLIAMSON 40 BERKSHIRE TERRACE NORTHAMPTON, MA 01062 1 1/2/2024 ROBIN CREAMER SITE PLAQUE NO SCALE 11x17 PV-P1 MAIN LOAD CENTER MAIN SERVICE DISCONNECT SOLAR PV EQUIPMNENT (BASEMENT) UTILITY SERVICE METER UTILITY SOLAR DISCONNECT (OUTSIDE) SOLAR ARRAY (GARAGE ROOF) SOLAR DC DISCONNECT NOT RAPID SHUTDOWN (OUTSIDE)