Loading...
10 michelman site plan plans v2 revisions 20230905Rev Date Description Project Title Issue Date: Drawn By: Checked By: Project ID: Drawing No. Project North 1 4/25/2023 DD drawings -- progress Sheet Title Scale: 9/5/2023 JPB JPB 22032 AS NOTED SITE REVIEW- 9/5/2022 This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.JODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.comProposed Renovations and Additions to 10 MICHELMAN AVE Northampton, Massachusetts 2 6/2/2023 Site Review 3 9/5/2023 Site Review -- revisions106'-0"81'-9 5/8"89'-3 1/2"70'-0"78'-6"101'-0" 109'-10 3/4" lot 143 lot 144 10'-0"front (URC)10'-0"side (URC)20'-0"rear (URC) 6'-0" rear CBg lot 143 lot 144 Z o n e U RC Z o n e CB g P L E A S A N T S T.MICHELMAN AVE.Site Plan -- PROPOSED Scale: 1" = 20'-0"2 NORTHNORTH Existing gravel driveway & parking Existing gravel driveway Existing gravel driveway between buildings Existing lawn / green space GAS washer dryer HWHelec panel DW ref.UPUP UP106'-0"81'-9 5/8"89'-3 1/2"70'-0"78'-6"101'-0" 109'-10 3/4" lot 143 lot 144 10'-0"front (URC)10'-0"side (URC)20'-0"rear (URC) 6'-0" rear CBg lot 143 lot 144 Z o n e U RC Z o n e CB g P L E A S A N T S T.MICHELMAN AVE.Site Plan -- EXISTING Scale: 1" = 20'-0"1 0 20 40 FT Existing paved driveway Existing gravel driveway & parking Existing gravel driveway Existing gravel driveway between buildings Existing lawn / green space SITE INFORMATION: Zone Multi-zone (approx. 2/3 CBg, 1/3 URC) CBg RequirementsLot size None Frontage None Width None Depth None Setbacks Side None Rear 6' Built-to-zone 0' to 10' Increase front setback?Special permit Driveway 20' Open Space None Ground floor use Residential 0' Residential park'g 0'; site District buffer 20'Porch/decknew lawn / green spacenew sidewalk SITE PLAN A-100 CBg Requirements (continued) Public Realm Furnishing/utlity 2' Pedestian 5' Lot Frontage 2' Building Massing Height (min/max)20'/70' Ground Floor ht.12' Upper Floor 10' Ground floor el.2' max./avg. Upper sty. setback 55'/10' The majority of the site is in zone CBg and its rules prevail (§ 350-6.9) URC requirements Lot size 3,750 sf Frontage 50' Width 50' Depth 75' Setbacks Front 10' Side 10' Rear 20' Garage 10' behind front of building Garage side, rear 4' Open Space 30% Max.Height 50'24'-0"30'-0" ±65'-7"±10'-7"Proposed new garage / workshop accessory building PHASE 1 Proposed new residence / renovation PHASE 2 Existing Garage / work space Rev Date Description Project Title Issue Date: Drawn By: Checked By: Project ID: Drawing No. Project North 1 4/25/2023 DD drawings -- progress Sheet Title Scale: 9/5/2023 JPB JPB 22032 AS NOTED SITE REVIEW- 9/5/2022 This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.JODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.comProposed Renovations and Additions to 10 MICHELMAN AVE Northampton, Massachusetts 2 6/2/2023 Site Review 3 9/5/2023 Site Review -- revisions D-01GAS D-13 D-16 washerdryerHWH elec panelDW ref. UP D-03 D-05 D-07 D-06 D-02 D-10 D-11 D-09 D-08 D-15 D-12 UPUP D-04 D-14 1st Floor Plan -- PROPOSED Scale: 1/4" = 1'-0"1 0 5 10 15 FT CLOS.LIVING SPACE 103 KITCHEN 104 ENTRY 101 OUTDOOR SPACE 100 BEDROOM 1 106 BEDROOM 3 110 BEDROOM 2 109 LAUNDRY / MECHANICAL 108 BATH 107 CLOSET DINING 102maximize storage under stairsnew windowexist opening new window new window new window new windowexist opening new window exist opening new windowexist openingnew windowexist openingnew windowexist openingnew window new door & side liteexist, modified opening new doorexist openingnew windowexist opening screen wallscreen wall low or screen wallCLOS. new window new window new window Shower 5'6"x3'4" linen 60'-0" 4'-11 7/8"2'-9"2'-3"2'-9"9'-10 1/2"1'-4"2'-10 7/8"1'-4"5'-3 7/8"2'-9"2'-8"2'-9"4'-2 1/4"1'-4"2'-3 5/8"1'-4"9'-2 1/8"30'-0"10'-0"8" EX. CMUTYPICAL4"11'-2"3 1/2"5'-0"3 1/2"8"4"15'-2 1/4" 3 1/2" 2'-0"3 1/2"11'-9 1/2"3 1/2"11'-1 3/4"3 1/2"5'-1"3 1/2"5'-2"3 1/2"5'-10 1/2" 4"8" CLOSET PANTRY 8"4"11'-2"3 1/2"2'-1"3 1/2"3'-9"3'-11 1/2"5 1/2"3'-2 1/2"3 1/2"6'-5 1/4"4"8"POWDER 105 threshold 7'-6"3'-8" 3 1/2" 13'-10 1/4" 4" 3 1/2"3'-11 1/2"3'-11 1/4"EQ.3 1/2"EQ.4"2'-10 1/2"3 1/2"3'-3 5/8"5 1/2"3'-6 1/2"6'-5 5/8"4'-8 3/8"CLOS.4"10'-5 5/8"3 1/2"8'-5 3/4"3 1/2"8'-5 3/4"4"4'-8"2'-9"6'-5 3/4"2'-9"7'-4"2'-9"3'-3 1/4"2'-8 1/2"3'-2"5'-7"3 1/2"7'-8 1/2" 1'-1"3'-1"2'-1" 2'-2 1/8"4'-0"2'-2 1/8"4'-0"6'-11 7/8" 6'-0" 6'-0"10'-4" EQ.EQ. 4'-0"10'-4"4'-0" 2'-1 3/4"3'-0 1/4"3'-0 1/4"2'-1 3/4" 30'-9" threshold low or screen wallscreen wall18'-6"new lawn / green space wood deck new sidewalk to entry existing gravel driveexisting lawn / green space existing gravel drive existing gravel driveFIRST FLOOR PLAN A-101 Rev Date Description Project Title Issue Date: Drawn By: Checked By: Project ID: Drawing No. Project North 1 4/25/2023 DD drawings -- progress Sheet Title Scale: 9/5/2023 JPB JPB 22032 AS NOTED SITE REVIEW- 9/5/2022 This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.JODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.comProposed Renovations and Additions to 10 MICHELMAN AVE Northampton, Massachusetts 2 6/2/2023 Site Review 3 9/5/2023 Site Review -- revisions WALK- IN CLOSET DOWN D-21 D-16 D-19 D-22 D-24 D-23 D-17 D-18 D-25 D-20 2nd Floor Plan -- PROPOSED Scale: 1/4" = 1'-0"1 0 5 10 15 FT WALK- IN CLOSET ROOF TERRACEM. BEDROOM 204 CLOSET linen OFFICE 201 CLOSET "BONUS ROOM" 202 high windowskylight PORTABLE HOT TUB -- LOCATION TBD MASTER BATH 203 W.C. 32"x48" shower 60'-0" 31'-0 1/2"28'-11 1/2" 2'-10 1/2"4'-7 1/4"4'-7 1/4"18'-11 5/8"30'-0"5 1/2"14'-6 3/4"3 1/2"3'-0"5 1/2"5'-1 1/2"3 1/2"5'-4 1/4"5 1/2"23'-11"7'-1 1/2" 9'-7 3/4"4'-9"4'-9"4'-9 1/4" 5 1/2"4'-1" 3 1/2" 11'-3 1/4"3 1/2"2'-6"5 1/2"11'-2 3/4"5 1/2"10'-0 1/4"EQ.EQ.19'-11 3/4"3'-1 3/4"9'-4 5/8"7'-5 3/8"5 1/2"9'-1 1/4"5 1/2"8'-3 1/2"5 1/2"10'-9 1/4"5 1/2"6'-1"2'-9"5 1/2"4'-1"3 1/2"18'-7 1/2"5 1/2" 5 1/2"8'-7 1/2"3 1/2"threshold3 1/2" 3'-4" 15'-0" shelves FUTURE SOLAR SECOND FLOOR PLAN A-102 Rev Date Description Project Title Issue Date: Drawn By: Checked By: Project ID: Drawing No. Project North 1 4/25/2023 DD drawings -- progress Sheet Title Scale: 9/5/2023 JPB JPB 22032 AS NOTED SITE REVIEW- 9/5/2022 This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.JODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.comProposed Renovations and Additions to 10 MICHELMAN AVE Northampton, Massachusetts 2 6/2/2023 Site Review 3 9/5/2023 Site Review -- revisionsGASwasherdryerHWHelec panelDW ref. UP UPUP 1st Floor Reflected Ceiling Plan -- PROPOSED Scale: 1/4" = 1'-0"1 0 5 10 15 FT CLOS.LIVING SPACE 103 KITCHEN 104 ENTRY 101 OUTDOOR SPACE 100 BEDROOM 1 106 BEDROOM 3 110 BEDROOM 2 109 LAUNDRY / MECHANICAL 108 BATH 107 CLOSET DINING 102maximize storage under stairsscreen wallscreen wall low or screen wallCLOS. Shower5'6"x3'4" linen CLOSET PANTRY POWDER 105 CLOS. Note: install undercabinet LED lighting in Kitchen. Coordinate locations & extent w/ Kitchen vendor. KEY: LED DOWN LIGHT, DIMMABLE, 3000K TEMP. R.2 P.1 DECORATIVE PENDANT , DINING P.2DECORATIVE PENDANT P.3 DECORATIVE PENDANT S.1 EXTERIOR SCONCE S.2 BATHROOM SCONCE, 1st FLOOR BATH EFLIGHT EXHAUST FAN & LIGHT COMBO UNIT S3 SD S LIGHT SWITCH 3-WAY LIGHT SWITCH DIMMER LIGHT SWITCH OUTLET 48"OUTLET & MOUNTING HEIGHT A.F.F. GFI OUTLET, GFI OUTLET, 208V CEILING FAN EXH FAN EXHAUST FAN P.4DECORATIVE PENDANT S.3 BATHROOM SCONCE, 2nd FLOOR BATH smokeCO SMOKE & CARBON MONOXIDE DETECTOR HEAT HEAT DETECTOR R.1 LED DOWN LIGHT, DIMMABLE, 3000K TEMP, WET LOCATION keyKEYLESS LIGHT FIXTURE w/ LED LAMP OUTLET, SWITCHEDswitch GENERAL NOTES: Review switching and outlet locations with Owner in field prior to final installation. Provide conduit & location for future solar. Provide conduit & location for future electric car charging station at rear of residence. Install outlets as directed by Electrical Code. Install additional outlets as indicated on plans and / or as requested by Owner. All lighting to be dimmable, LED, 3000K unless otherwise noted. All exterior lighting to be 3000K or lower, down light only S.1S.1S.1S.1 P.1P.2P.2P.3 P.3 P.3 P.4P.4R.2 R.1 R.1 R.1 R.1 R.1 R.1 R.1 R.1S.2S.2R.1R.1 R.1R.1 EFLIGHT R.2 R.1 R.1 R.1R.1R.1 R.1 R.1 line of mezzanine TV GFI S.24' LED fixture2' LED fixture2' LED fixture2' LED fixture 2' LED fixture R.1 R.1 R.1R.1 GFI GFI Dishwasherstoveexhaust GFI S.1 FIRST FLOOR CEILING PLAN A-111 Rev Date Description Project Title Issue Date: Drawn By: Checked By: Project ID: Drawing No. Project North 1 4/25/2023 DD drawings -- progress Sheet Title Scale: 9/5/2023 JPB JPB 22032 AS NOTED SITE REVIEW- 9/5/2022 This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.JODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.comProposed Renovations and Additions to 10 MICHELMAN AVE Northampton, Massachusetts 2 6/2/2023 Site Review 3 9/5/2023 Site Review -- revisions WALK- IN CLOSET DOWN 2nd Floor Reflected Ceiling Plan -- PROPOSED Scale: 1/4" = 1'-0"1 0 5 10 15 FT WALK- IN CLOSET ROOF TERRACE M. BEDROOM 204 CLOSET linen OFFICE 201 CLOSET "BONUS ROOM" 202 high windowskylight PORTABLE HOT TUB -- LOCATION TBD -- provide powerMASTER BATH 203 W.C. 32"x48" showerthresholdshelves KEY: LED DOWN LIGHT, DIMMABLE, 3000K TEMP. R.2 P.1 DECORATIVE PENDANT , DINING P.2DECORATIVE PENDANT P.3 DECORATIVE PENDANT S.1 EXTERIOR SCONCE S.2 BATHROOM SCONCE, 1st FLOOR BATH EF LIGHT EXHAUST FAN & LIGHT COMBO UNIT S3 SD S LIGHT SWITCH 3-WAY LIGHT SWITCH DIMMER LIGHT SWITCH OUTLET 48"OUTLET & MOUNTING HEIGHT A.F.F. GFI OUTLET, GFI OUTLET, 208V CEILING FAN EXHFAN EXHAUST FAN P.4DECORATIVE PENDANT S.3 BATHROOM SCONCE, 2nd FLOOR BATH smokeCO SMOKE & CARBON MONOXIDE DETECTOR HEAT HEAT DETECTOR R.1 LED DOWN LIGHT, DIMMABLE, 3000K TEMP, WET LOCATION keyKEYLESS LIGHT FIXTURE w/ LED LAMP OUTLET, SWITCHEDswitch GENERAL NOTES: Review switching and outlet locations with Owner in field prior to final installation. Provide conduit & location for future solar. Provide conduit & location for future electric car charging station at rear of residence. Install outlets as directed by Electrical Code. Install additional outlets as indicated on plans and / or as requested by Owner. All lighting to be dimmable, LED, 3000K unless otherwise noted. All exterior lighting to be 3000K or lower, down light only EXH FAN S.1S.1S.1S.1R.2S.3 S.3 R.2 R.2 R.2 R.1 R.1 R.1 R.1 R.1 R.1 R.1 R.1 R.1 R.1 R.1 R.1 R.1 R.1 R.1 R.1 R.1 R.1 R.1 R.1 GFIGFISECOND FLOOR CEILING PLAN A-112 1/A-201 bot. of joists ±12'0" grade / slab 0'0" 1st floor ±1'5" 2nd floor ±14'4" ex. raised slab, ±0-5" Front Elevation (Michelman Ave., Plan West) -- PROPOSED Scale: 1/4" = 1'-0"1 0 5 10 15 FT Rev Date Description Project Title Issue Date: Drawn By: Checked By: Project ID: Drawing No. Project North 1 4/25/2023 DD drawings -- progress Sheet Title Scale: 9/5/2023 JPB JPB 22032 AS NOTED SITE REVIEW- 9/5/2022 This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.JODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.comProposed Renovations and Additions to 10 MICHELMAN AVE Northampton, Massachusetts 2 6/2/2023 Site Review 3 9/5/2023 Site Review -- revisions bot. of joists, front ±12'0" grade / slab 0'0" 1st floor ±1'5" 2nd floor ±14'4" bot. of joists, rear ±11'4" ex. raised slab, ±0-5" Sidse Elevation (Plan South) -- PROPOSED Scale: 1/4" = 1'-0"2 0 5 10 15 FT GASHWH elec panelUP UPUP 2/A-201KEY PLAN EXTERIOR ELEVATIONS A-201 bot. of joists, front ±12'0" grade / slab 0'0" 1st floor ±1'5" 2nd floor ±14'4" bot. of joists, rear ±11'4" bot. of joists, front ±12'0" grade / slab 0'0" 1st floor ±1'5" 2nd floor ±14'4" bot. of joists, rear ±11'4" ex. raised slab, ±0-5" Rear Elevation (Plan East) -- PROPOSED Scale: 1/4" = 1'-0"1 0 5 10 15 FT Rev Date Description Project Title Issue Date: Drawn By: Checked By: Project ID: Drawing No. Project North 1 4/25/2023 DD drawings -- progress Sheet Title Scale: 9/5/2023 JPB JPB 22032 AS NOTED SITE REVIEW- 9/5/2022 This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.JODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.comProposed Renovations and Additions to 10 MICHELMAN AVE Northampton, Massachusetts 2 6/2/2023 Site Review 3 9/5/2023 Site Review -- revisions bot. of joists, front ±12'0" grade / slab 0'0" 1st floor ±1'5" 2nd floor ±14'4" bot. of joists, rear ±11'4" ex. raised slab, ±0-5" Side Elevation (Plan North) -- PROPOSED Scale: 1/4" = 1'-0"2 0 5 10 15 FT GAS HWH elec panelUP UP UP 1/A-202 2/A-202KEY PLAN EXTERIOR ELEVATIONS A-202