Loading...
Habitat-Northampton 785 Burts Pit-EP BinderM.D.P.U. No. 1468 Canceling M.D.P.U. No. 1320 Sheet 104 of 170 STANDARDS FOR INTERCONNECTION OF DISTRIBUTED GENERATION Exhibit A ATTACHMENT 2 Certificate of Completion for Simplified Process Interconnections Installation Information:Check if owner-installed Interconnecting Customer Name (print): _____________________________________________ Contact Person: ________________________________________________________________ Mailing Address: _______________________________________________________________ City: ________________________________State: ________________ Zip Code: __________ Telephone (Daytime): __________________ (Evening): ________________________________ Facsimile Number: ____________________ E-Mail Address: ___________________________ Address of Facility (if different from above): Electrical Contractor’s Name (if appropriate): ________________________________________ Mailing Address: _______________________________________________________________ City: ________________________________State: ________________ Zip Code: __________ Telephone (Daytime): __________________ (Evening): ________________________________ Facsimile Number: ____________________ E-Mail Address: ___________________________ License number: _________________________ Date of approval to install Facility granted by the Company: _______________________ Application ID number: ______________________________ Inspection: The system has been installed and inspected in compliance with the local Building/Electrical Code of (City/County) Signed (Local Electrical Wiring Inspector, or attach signed electrical inspection): Name (printed): ________________________________________________________________ Date: ___________________ License # ________________________ PV SQUARED 311 WELLS ST. SUITE B GREENFIELD MA 01301 413-772-8788 interconnection@pvsquared.coop 3877 A1 PIONEER VALLEY HABITAT FOR HUMANITY INC MEGAN MCDONOUGH PO BOX 60642 FLORENCE MA 01062-0642 (413) 586-5430 MEGAN@PVHABITAT.ORG 785 BURTS PIT RD LOT 7 NORTHAMPTON MA 01062 7/20/23 00540442 M.D.P.U. No. 1468 Canceling M.D.P.U. No. 1320 Sheet 105 of 170 STANDARDS FOR INTERCONNECTION OF DISTRIBUTED GENERATION Exhibit A As a condition of interconnection you are required to send/fax a copy of this form along with a copy of the signed electrical permit to (insert Company’s name below): Name: _____________________ Company: __________________ Mail 1:_____________________ Mail 2:_____________________ City, State ZIP: ______________ Fax No.: ___________________ ATTN: DISTRIBUTED GENERATION WALTHAM, MA 02451 NATIONAL GRID 40 SYLVAN RD DISTRIBUTED.GENERATION@NATIONALGRID.COM 01/05/2023 Alera Group, Inc. Webber & Grinnell Division 8 North King Street Northampton MA 01060 Kathy Parker (413) 586-0111 (413) 586-6481 kparker@webberandgrinnell.com Pioneer Valley PhotoVoltaics Cooperative, Inc. Attn: Kim Pinkham 311 Wells Street, Suite B Greenfield MA 01301 Ohio Casualty/Liberty 24074 Ohio Security/Liberty 24082 Continental Indemnity/AUW 28258 CL231519687 A BKS57072282 01/01/2023 01/01/2024 1,000,000 300,000 15,000 1,000,000 2,000,000 2,000,000 B BAS57072282 01/01/2023 01/01/2024 1,000,000 Underinsured motorist 300,000 A 10,000 USO57072282 01/01/2023 01/01/2024 5,000,000 5,000,000 C N 375928710105 01/01/2023 01/01/2024 1,000,000 1,000,000 1,000,000 A Commercial Property BKS57072282 01/01/2023 01/01/2024 Blanket BPP $1,483,977 Transportation $25,000 Installation $75,000 Worker's compensation includes MA and NY Proof of Insurance SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. INSURER(S) AFFORDING COVERAGE INSURER F : INSURER E : INSURER D : INSURER C : INSURER B : INSURER A : NAIC # NAME:CONTACT (A/C, No):FAX E-MAILADDRESS: PRODUCER (A/C, No, Ext):PHONE INSURED REVISION NUMBER:CERTIFICATE NUMBER:COVERAGES IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. OTHER: (Per accident) (Ea accident) $ $ N / A SUBR WVD ADDL INSD THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. $ $ $ $PROPERTY DAMAGE BODILY INJURY (Per accident) BODILY INJURY (Per person) COMBINED SINGLE LIMIT AUTOS ONLY AUTOSAUTOS ONLY NON-OWNED SCHEDULEDOWNED ANY AUTO AUTOMOBILE LIABILITY Y / N WORKERS COMPENSATION AND EMPLOYERS' LIABILITY OFFICER/MEMBER EXCLUDED? (Mandatory in NH) DESCRIPTION OF OPERATIONS below If yes, describe under ANY PROPRIETOR/PARTNER/EXECUTIVE $ $ $ E.L. DISEASE - POLICY LIMIT E.L. DISEASE - EA EMPLOYEE E.L. EACH ACCIDENT EROTH-STATUTEPER LIMITS(MM/DD/YYYY)POLICY EXP(MM/DD/YYYY)POLICY EFFPOLICY NUMBERTYPE OF INSURANCELTRINSR DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) EXCESS LIAB UMBRELLA LIAB $EACH OCCURRENCE $AGGREGATE $ OCCUR CLAIMS-MADE DED RETENTION $ $PRODUCTS - COMP/OP AGG $GENERAL AGGREGATE $PERSONAL & ADV INJURY $MED EXP (Any one person) $EACH OCCURRENCE DAMAGE TO RENTED $PREMISES (Ea occurrence) COMMERCIAL GENERAL LIABILITY CLAIMS-MADE OCCUR GEN'L AGGREGATE LIMIT APPLIES PER: POLICY PRO-JECT LOC CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DD/YYYY) CANCELLATION AUTHORIZED REPRESENTATIVE ACORD 25 (2016/03) © 1988-2015 ACORD CORPORATION. All rights reserved. CERTIFICATE HOLDER The ACORD name and logo are registered marks of ACORD HIRED AUTOS ONLY The Commonwealth of Massachusetts Department of Industrial Accidents 1 Congress Street, Suite 100 Boston, MA 02114-2017 www.mass.gov/dia Workers’ Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name (Business/Organization/Individual):______________________________________________________ Address:__________________________________________________________________________ City/State/Zip:_____________________________ Phone #:________________________________ *Any applicant that checks box #1 must also fill out the section below showing their workers’ compensation policy information. †Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. ‡Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees, they must provide their workers’ comp. policy number. I am an employer that is providing workers’ compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:____________________________________________________________________________ Policy # or Self-ins. Lic. #:__________________________________________ Expiration Date:____________________ Job Site Address: City/State/Zip:______________________ Attach a copy of the workers’ compensation policy declaration page (showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152, §25A is a criminal violation punishable by a fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury that the information provided above is true and correct. Signature: Date: Phone #: Official use only. Do not write in this area, to be completed by city or town official. City or Town: ___________________________________ Permit/License #_________________________________ Issuing Authority (circle one): 1. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6. Other ______________________________ Contact Person:_________________________________________ Phone #:_________________________________ Type of project (required): 7. New construction 8. Remodeling 9. Demolition 10 Building addition 11. Electrical repairs or additions 12. Plumbing repairs or additions 13. Roof repairs 14. Other____________________ 1. I am a employer with _________employees (full and/or part-time).* 2. I am a sole proprietor or partnership and have no employees working for me in any capacity. [No workers’ comp. insurance required.] 3. I am a homeowner doing all work myself. [No workers’ comp. insurance required.] † 4. I am a homeowner and will be hiring contractors to conduct all work on my property. I will ensure that all contractors either have workers’ compensation insurance or are sole proprietors with no employees. 5. I am a general contractor and I have hired the sub-contractors listed on the attached sheet. These sub-contractors have employees and have workers’ comp. insurance.‡ 6. We are a corporation and its officers have exercised their right of exemption per MGL c. 152, §1(4), and we have no employees. [No workers’ comp. insurance required.] Are you an employer? Check the appropriate box: J-Box INV #1 UTILTIY XMFR 120/240V, 1PHASE POINT OF COMMON COUPLING INVERTER INTEGRATED DC DISCONNECT INTERNET CONNECTION (EXISTING LAN) D 1 CBA 2 18 - MODULES / 18 - OPTIMIZERS STRING (1) = 9 OPTIMIZERS STRING (2) = 9 OPTIMIZERS ARRAY & STRING SIZING NOTES: ·MIN (8) MODULES PER STRING, (6) IF USING P505 OR S500B ·MAX (17) MODULES PER STRING (5700 WATTS DC) ·IF THE ARRAY AND STRINGS ARE SPLIT BETWEEN MULTIPLE ROOF PLANES. USE EXTRA ROOF BOXES/CONDUITS TO JOIN ROOF PLANES/STRINGS AS NEEDED. ·KEEP MIN NUMBER OF MODULES WITHIN EACH STRING WITHIN 90° AZIMUTH OF EACH OTHER. ·DO NOT EXCEED THE MAXIMUM DC POWER PER STRING AND INVERTER. 3 E F 4 G EXISTING EQUIPMENT NEW EQUIPMENT OUTSIDE - ON ROOF OUTSIDE - WITHIN10' OF UTILITY METER OUTSIDE - SERVICE LOCATIONINSIDE - UTILITY SPACE 3 200A-2PLOADS LOADS MAIN LOAD CENTER 35A-2P 200A-2P METER/MAIN SERVICE DISCONNECT M UTILITY METER WITH INTEGRATED LOAD PANEL POINT OF SOLAR INTERCONNECTION IF NO MAIN BREAKER IS INSTALLED IN MAIN PANEL THEN ADD LOAD SIDE OCP AFTER SOLAR INTERCONNECTION POINT (ADD LABEL 219 " EQUIPMENT FED BY MULTIPLE SOURCES...") SOLAR PV RAPID SHUTDOWN UTILITY ACCESSIBLE DISCONNECT INVERTER GRID TRIP SETTINGS FREQUENCY & VOLTAGE - IEEE 1547-2018 and UL 1741 SB TRIP FUNCTIONS PICKUP RANGE CLEARING TIMES Under Frequency (81U)< 56.5 Hz 0.16 Under Frequency (81U)< 58.5 Hz 300 Over Frequency (81O)61.2 Hz < f <62.0Hz 300 Over Frequency (81O)> 62.0 Hz 0.16 Under Voltage (27)< 50% of Nom.1.1 Under Voltage (27)50% <V< 88% of Nom.3 Over Voltage (59)110% <V< 120% of Nom.2 Over Voltage (59)≥ 120% of Nom.0.16 INTERCONNECTION CALCULATIONS ITEM VALUE POWER PHASE 1 Phase NOMINAL GRID VOLTAGE (V)240 INVERTER(S) MAX CONTINUOUS AC OUTPUT CURRENT PER PHASE (A)25 TOTAL MAX AC OUTPUT CURRENT WITH CON. USE (*1.25%)(A)31.25 INVERTER(S) INTERCONNECTION OCPD USED (A)35 MAIN OCP DISCONNECT (A)200 *MAIN PANEL BUSS AMPACITY (A)200 NEC ALLOWABLE (PANEL BUSS) BACKFEED AMPS AT 120% (A)40 *LOAD SIDE BREAKER INTERCONNECTION SYSTEM OVERVIEW 5.886 kW - DC SOLAR 6 kW - AC SOLAR EQUIPMENT (18) SunPower RES-DC-327-WHT (18) SolarEdge P400 [Alt.Opti, P400, P485, P505, S500B] (1) SolarEdge 6kw HD-Wave w/ RGM UTILITY / AHJ / CODE: NGrid Jurisdiction Of Northampton 2023 NEC (MA) CONDUCTOR SCHEDULE & CALCULATIONS KEY DESCRIPTION QTY CONDUCTORS CONDUIT COND (A)TERM (A)REQ'D (A)OCP LENGTH VDROP% 1 DC - OPTIMIZER TO JBOX (PV SOURCE)4 #10 - PV WIRE/USE-2 90°C (CU) FREE AIR 32A 40A 18.75A 20A 50ft 0.51% EGC 1 #6 - BARE WIRE (CU) 2 DC - JBOX TO INVERTER 4 #10 - THHN/THWN-2 90°C (CU) .75" - EMT 32A 40A 18.75A 20A 100ft 1.02% EGC 1 #10 - THHN/THWN-2 90°C (CU) 3 AC - INVERTER OUTPUT 2 #8 - THHN/THWN-2 90°C (CU) .75" - EMT 55A 50A 31.25A 35A 50ft 0.81%EGC 1 #10 - THHN/THWN-2 90°C (CU) NEUTRAL 1 #8 - THHN/THWN-2 90°C (CU) 4 AC - SERVICE CONDUCTORS 2 #4/0 - XHHW/THWN 75°C (AL) CABLE - PVC 180A 180A 166A 200A 15ft 0.25% NEUTRAL 1 #4/0 - XHHW/THWN 75°C (AL) EQUIPMENT SCHEDULE KEY QTY DESCRIPTION DATA / MAKE / MODEL A 18 SOLAR MODULE SunPower, SunPower RES-DC-327-WHT, SPR-E20-327, 327-Watts, 64.9V-Voc, 6.46A-Isc, (77.23V-Calculated Voc) B 18 POWER OPTIMIZER SolarEdge P400 [Alt.Opti, P400, P485, P505, S500B] C 1 ARRAY MOUNTED JUNCTION BOX EZ SOLAR, NEMA-3R, ROOF JUNCTION BOX (2 STRING), JB-1.2 D 1 SOLAR INVERTER SolarEdge 6kW HD-Wave w/ RGM, 1 Phase, 240V, 25A, 6kW AC (on grid) Max E 1 SOLAR, UTILITY ACCESSIBLE, RAPID SHUTDOWN DISCONNECT SqD, DU222RB, 60A, 240V, NON-Fusible, NEMA-3R (Outdoor), 2P, General Duty, Disconnect F 1 MAIN LOAD PANEL EXISTING: 1PHASE, 120/240V, 200A/200A G 1 UTILITY SERVICE METER / MAIN EXISTING: 1PHASE, 120/240V, 200A/200A, UG, INTEGRATED PANEL (LEVITON LP820-LMC) NEED: (1) 35A-2P LEVITON BRK GENERAL NOTES ALL (DC/AC) CONDUCTORS TO BE 600V MIN. RATED UNLESS OTHERWISE NOTED. ARRAY ELECTRICAL BONDING THROUGH LISTED RACKING GROUNDING SYSTEM. SOLAR PV EQUIPMENT CONNECTED TO SERVICE GROUNDING ELECTRODE SYSTEM INSTALLATION SUBJECT TO CHANGE BASED ON FIELD CONDITIONS INSTALLATION SUBJECT TO AHJ APPROVAL WIRE AND CONDUIT SIZES SHOULD BE ADJUSTED FOR VOLTAGE DROP/RISE AS NEEDED. TOTAL VOLTAGE DROP/RISE FOR SERIES CONNECTED WIRING (PV TO POINT OF INTERCONNECTION) SHOULD BE LESS THAN: (DC < ~2%) (AC < ~1.25%) MAX RATE OF POWER EXPORT TO THE POCC IS LIMITED BY THE TOTAL INVERTER(S) AC RATING ALL UTILITY EQUIPMENT AND CUSTOMER DISCONNECTING MEANS WILL BE 24/7 UTILITY ACCESSIBLE, LOCKABLE, GROUPED WITH ANY METERING AND LOCATED OUTSIDE. LABELS / VALUES PHOTOVOLTAIC DC DISCONNECT MAX DC SYSTEM VOLTS 480 OPERATING DC VOLTS 400 OPERATING DC AMPS (@INV)14.72 PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT 31.25 NOMINAL AC OPERATING VOLTAGE 240 311 WELLS STREET, SUITE B GREENFIELD, MA 01301 WWW.PVSQUARED.COOP 413-772-8788 SIZE: PV SQUARED SOLAR SCALE: DATE: BY: REV: PROJECT: CLIENT: SITE: HABITAT 785 BURTS PIT NORTHAMPTON P. V. HABITAT FOR HUMANITY MEGAN MCDONOUGH 785 BURTS PIT RD. NORTHAMPTON, MA 01062 0 6/1/2023 MAYA FULFORD ELECTRICAL SINGLE LINE NO SCALE 11x17 PV-E1  E-Series Residential Solar Panels                       Datasheet   More than 20% Efficiency Ideal for roofs where space is at a premium or where future expansion might be needed.   High Performance Delivers excellent performance in real-world conditions, such as high temperatures, clouds and low light.1,2,4   Proven Value Designed for residential rooftops, E-Series panels deliver the features, value and performance for any home.   Maxeon® Solar Cells: Fundamentally better Engineered for performance, designed for durability. Engineered for Peace of Mind Designed to deliver consistent, trouble-free energy over a very long lifetime. 3,4   Designed for Durability The SunPower Maxeon Solar Cell is the only cell built on a solid copper foundation. Virtually impervious to the corrosion and cracking that degrade conventional panels. 3   #1 Rank in Fraunhofer durability test.9 100% power maintained in Atlas 25+ comprehensive durability test.10       High Performance & Excellent Durability High Efficiency5 Generate more energy per square foot E-Series residential panels convert more sunlight to electricity by producing 31% more power per panel1 and 60% more energy per square foot over 25 years.1,2,3 High Energy Production6 Produce more energy per rated watt High year-one performance delivers 7–9% more energy per rated watt.2 This advantage increases over time, producing 20% more energy over the first 25 years to meet your needs.3 00 0 5 10 15 20 25 SunPower E-Series Conventional 25-Year Energy Production / WattYears 50% 60% 70% 80% 90% 110% 100% 120% 35% more, year 25 8% more, year 1 000020% More Energy Per Rated Watt 0% 2% 4% 6% 8% 10% Maintains High Power at High Temps No Light-Induced Degradation High Average Watts High-Performance Anti-Reflective Glass Better Low-Light and Spectral Response Year 1 Energy Advantage / Watt  20               SPR-E20-327 SunPower® E-Series Residential Solar Panels | E20-327  E-Series Residential Solar Panels  Tests And Certifications Standard Tests13 UL1703 (Type 2 Fire Rating), IEC 61215, IEC 61730 Quality Certs ISO 9001:2008, ISO 14001:2004 EHS Compliance RoHS, OHSAS 18001:2007, lead free, REACH SVHC-163, PV Cycle Sustainability Cradle to Cradle CertifiedTM Silver (eligible for LEED points)14 Ammonia Test IEC 62716 Desert Test 10.1109/PVSC.2013.6744437 Salt Spray Test IEC 61701 (maximum severity) PID Test Potential-Induced Degradation free: 1000 V9 Available Listings15 UL, TUV, JET, MCS, FSEC, CEC Operating Condition And Mechanical Data Temperature –40° F to +185° F (–40° C to +85° C) Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s) Appearance Class A Solar Cells 96 Monocrystalline Maxeon Gen II Tempered Glass High-transmission tempered anti-reflective Junction Box IP-65, MC4 compatible Weight 41 lbs (18.6 kg) Max. Load G5 Frame: Wind: 62 psf, 3000 Pa front & back Snow: 125 psf, 6000 Pa front G3 Frame: Wind: 50 psf, 2400 Pa front & back Snow: 112 psf, 5400 Pa front Frame Class 1 black anodized (highest AAMA rating) G5 FRAME PROFILE G3 FRAME PROFILE 30 mm [1.2 in] [1.8 in]InvisiMountTM Compatible Not InvisiMount Compatible 1558 mm [61.3 in] 1046 mm [41.2 in] 46 mm [1.8 in] 46 mm32 mm [1.3 in] LONG SIDE 22 mm [0.9 in] SHORT SIDE [1.8 in] 46 mm G5 frames have no mounting holes. Please read the safety and installation guide.                                                                            Electrical Data SPR-E20-327 SPR-E19-320 Nominal Power (Pnom)11 327 W 320 W Power Tolerance +5/–0% +5/–0% Avg. Panel Efficiency12 20.4% 19.9% Rated Voltage (Vmpp) 54.7 V 54.7 V Rated Current (Impp) 5.98 A 5.86 A Open-Circuit Voltage (Voc) 64.9 V 64.8 V Short-Circuit Current (Isc) 6.46 A 6.24 A Max. System Voltage 600 V UL & 1000 V IEC Maximum Series Fuse 15 A Power Temp Coef. –0.35% / o C Voltage Temp Coef. –176.6 mV / o C Current Temp Coef. 2.6 mA / o C REFERENCES: 1 All comparisons are SPR-E20-327 vs. a representative conventional panel: 250 W, approx. 1.6 m², 15.3% efficiency. 2 Typically 7–9% more energy per watt, BEW/DNV Engineering “SunPower Yield Report,” Jan 2013. 3 SunPower 0.25%/yr degradation vs. 1.0%/yr conv. panel. Campeau, Z. et al. “SunPower Module Degradation Rate,” SunPower white paper, Feb 2013; Jordan, Dirk “SunPower Test Report,” NREL, Q1-2015. 4 “SunPower Module 40-Year Useful Life” SunPower white paper, May 2015. Useful life is 99 out of 100 panels operating at more than 70% of rated power. 5 Second highest, after SunPower X-Series, of over 3,200 silicon solar panels, Photon Module Survey, Feb 2014. 6 8% more energy than the average of the top 10 panel companies tested in 2012 (151 panels, 102 companies), Photon International, Feb 2013. 7 Compared with the top 15 manufacturers. SunPower Warranty Review, May 2015. 8 Some restrictions and exclusions may apply. See warranty for details. 9 5 of top 8 panel manufacturers tested in 2013 report, 3 additional panels in 2014. Ferrara, C., et al. "Fraunhofer PV Durability Initiative for Solar Modules: Part 2". Photovoltaics International, 2014. 10 Compared with the non-stress-tested control panel. Atlas 25+ Durability test report, Feb 2013. 11 Standard Test Conditions (1000 W/m² irradiance, AM 1.5, 25° C). NREL calibration Standard: SOMS current, LACCS FF and Voltage. 12 Based on average of measured power values during production. 13 Type 2 fire rating per UL1703:2013, Class C fire rating per UL1703:2002. 14 See salesperson for details. 15 Only SPR-E20-327 has JET certification. SunPower Offers The Best Combined Power And Product Warranty Power Warranty Product Warranty 75% 80% 85% 90% 95% 100% 0 5 10 15 20 25 Years Traditional Warranty SunPower Conventional panel “linear” warranty 0 5 10 15 20 25 SunPower Traditional Warranty Years   More guaranteed power: 95% for first 5 years, −0.4%/yr. to year 25 7  Combined Power and Product defect 25­year coverage 8   Document # 504860 Rev F /LTR_US ©December 2016 SunPower Corporation. All rights reserved. SUNPOWER, the SUNPOWER logo, MAXEON, SIGNATURE and InvisiMount are trademarks or registered trademarks of SunPower Corporation. Specifications included in this datasheet are subject to change without notice. SunPower® E-Series Residential Solar Panels | E20-327 See www.sunpower.com/facts for more reference information. For more details, see extended datasheet: www.sunpower.com/datasheets. SunPower® E-Series Residential Solar Panels | E20-327 INVERTERSsolaredge.com Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Built-in module-level monitoring Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) Record-breaking 99% weighted efficiency Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp Fixed voltage inverter for longer strings UL1741 SA certified, for CPUC Rule 21 grid compliance Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020 per article 690.11 and 690.12 Small, lightweight, and easy to install both outdoors or indoors Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US 12-25 YEARWARRANTY MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4 OUTPUT Rated AC Power Output 3000 3800 @ 240V3300 @ 208V 5000 6000 @ 240V5000 @ 208V 7600 10000 11400 @ 240V10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V3300 @ 208V 5000 6000 @ 240V5000 @ 208V 7600 10000 11400 @ 240V10000 @ 208V VA AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)----Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V -16 -24 --48.5 A Power Factor 1, Adjustable - 0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V -5100 -7750 --15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(2)8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2)-9 -13.5 --27 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V98.5 @ 208V % Nighttime Power Consumption < 2.5 W (1) For other regional settings please contact SolarEdge support (2) A higher current source may be used; the inverter will limit its input current to the values stated SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US Single Phase Inverter with HD-Wave Technology for North America MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Metering, ANSI C12.20 Optional(3)Consumption metering Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown - NEC 2014, NEC 2017 and NEC 2020, 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1'' Maximum / 14-6 AWG 1'' Maximum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 1'' Maximum / 1-2 strings / 14-6 AWG 1'' Maximum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(4)˚F / ˚C Protection Rating NEMA 4X (Inverter with Safety Switch) (3) Inverter with Revenue Grade Meter P/N: SExxxxH-US000BNC4; Inverter with Revenue Grade Production and Consumption Meter P/N: SExxxxH-US000BNI4 . For consumption metering, current transformers should be ordered separately: SEACT0750-200NA-20 or SEACT0750-400NA-20. 20 units per box(4) Full power up to at least 50˚C / 122˚F; for power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2020/V01/ENG NAM. Subject to change without notice. Power Optimizer For North America P370 / P400 / P401 / P485 / P505 25 YEAR WARRANTY PV power optimization at the module-level Specifically designed to work with SolarEdge inverters Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module- level monitoring Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) Module-level voltage shutdown for installer and firefighter safety solaredge.com POWER OPTIMIZER Power Optimizer For North America P370 / P400 / P401 / P485 / P505 Optimizer model (typical module compatibility) P370 (for higher-power 60 and 72-cell modules) P400 (for 72 & 96- cell modules) P401 (for high power 60 and 72 cell modules) P485 (for high-voltage modules) P505 (for higher current modules) INPUT Rated Input DC Power(1) 370 400 430 485 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 60 80 60 125(2) 83(2) Vdc MPPT Operating Range 8 - 60 8 - 80 8-60 12.5 - 105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc) 11 10.1 12.5 11 14 Adc Maximum DC Input Current 13.75 12.5 14.65 12.5 17.5 Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 80 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741, NEC/PVRSS Material UL94 V-0 , UV Resistant RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H) 129 x 153 x 27.5 / 5.1 x 6 x 1.1 129 x 153 x 33.5 / 5.1 x 6 x 1.3 129 x 153 x 29.5 / 5.1 x 6 x 1.16 129 x 159 x 49.5 / 5.1 x 6.3 x 1.9 129 x 162 x 59 / 5.1 x 6.4 x 2.3 mm / in Weight (including cables) 630 / 1.4 750 / 1.7 655 / 1.5 845 / 1.9 1064 / 2.3 gr / lb Input Connector MC4(3) MC4(3) MC4(3) Input Wire Length 0.16 / 0.5 m / ft Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 1.2 / 3.9 m / ft Operating Temperature Range (4) -40 to +85 / -40 to +185 ˚C / ˚F Protection Rating IP68 / Type6B Relative Humidity 0 - 100 % (1) Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed (2) NEC 2017 requires max input voltage be not more than 80V (3) For other connector types please contact SolarEdge (4) Longer inputs wire lengths are available for use. For 0.9m input wire length order P401-xxxLxxx (5) For ambient temperature above +85°C / +185°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details: https://www.solaredge.com/sites/default/files/se- temperature-derating-note-na.pdf PV System Design Using a SolarEdge Inverter(6)(7) Single Phase HD-Wave Single phase Three Phase for 208V grid Three Phase for 277/480V grid Minimum String Length (Power Optimizers) P370, P400, P401 8 10 18 P485, P505 6 8 14 Maximum String Length (Power Optimizers) 25 25 50 Maximum Power per String 5700(8) (6000 with SE7600-US - SE11400-US) 5250(8) 6000(9) 12750(10) W Parallel Strings of Different Lengths or Orientations Yes (6) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf (7) It is not allowed to mix P485/P505 with P370/P400/P401 in one string (8) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement (9) For 208V grid: it is allowed to install up to 6,500W per string when the maximum power difference between each string is 1,000W (10)For 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W © SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: February 10, 2022 DS-000044-NA. Subject to change without notice. Power Optimizer For North America S440, S500 25 YEAR WARRANTY PV power optimization at the module level Specifically designed to work with SolarEdge residential inverters Faster installations with simplified cable management and easy assembly using a single bolt Detects abnormal PV connector behavior, preventing potential safety issues* Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Flexible system design for maximum space utilization Compatible with bifacial PV modules Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading * Expected availability in 2022 solaredge.com POWER OPTIMIZER Power Optimizer For North America S440, S500 S440 S500 Unit INPUT Rated Input DC Power(1) 440 500 W Absolute Maximum Input Voltage (Voc) 60 Vdc MPPT Operating Range 8 - 60 Vdc Maximum Short Circuit Current (Isc) of Connected PV Module 14.5 15 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 % Overvoltage Category II OUTPUT DURING OPERATION Maximum Output Current 15 Adc Maximum Output Voltage 60 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1+/-0.1 Vdc STANDARD COMPLIANCE Photovoltaic Rapid Shutdown System NEC 2014, 2017 & 2020 EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant RoHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 129 x 153 x 30 / 5.07 x 6.02 x 1.18 mm / in Weight (including cables) 655 / 1.5 gr / lb Input Connector MC4(2) Input Wire Length 0.1 / 0.32 m / ft Output Connector MC4 Output Wire Length (+) 2.3, (-) 0.10 / (+) 7.54, (-) 0.32 m / ft Operating Temperature Range(3) -40 to +85 ˚C Protection Rating IP68 / Type6B Relative Humidity 0 - 100 % (1) Rated power of the module at STC will not exceed the power optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed (2) For other connector types please contact SolarEdge (3) For ambient temperature above +70°C / +158°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details PV System Design Using a SolarEdge Inverter Single Phase HD-Wave Three Phase for 208V grid Three Phase for 277/480V grid Minimum String Length (Power Optimizers) S440, S500 8 14 18 Maximum String Length (Power Optimizers) 25 50(4) Maximum Nominal Power per String 5700 (6000 with SE7600-US-SE11400-U) 6000 12750 W Maximum Allowed Connected Power per String (5) (Permitted only when the difference in connected power between strings is 1,000W or less) Refer to Footnote 5 One String 7200W 15,000W Two strings or more 7800W Parallel Strings of Different Lengths or Orientations Y (4) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement (5) If the inverters rated AC power ≤ maximum nominal power per string, then the maximum power per string will be able to reach up to the inverters maximum input DC power. Refer to: https://www.solaredge.com/ sites/default/files/se-power-optimizer-single-string-design-application-note.pdf (6) It is not allowed to mix S-series and P-series Power Optimizers in new installations © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or r egistered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: February 8, 2022 DS-000018-NA. Subject to change without notice.