CS carrying Beam CalcsCS Structure™ 2018.9 [Build 16] kmBeamEngine 2018.9.0.1 Materials Database 1572 RosemundBrownElkins - Level 6 9-10-19 9:14am 1 of 4 All product names are trademarks of their respective owners Copyright (C) 2018 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB2 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 18.1 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 11' 8.00" 233 58 Live Replacement Uniform (PLF) Top 0' 0.00" 11' 8.00" 560 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 11' 8.00" 453 457 Live Replacement Uniform (PLF) Top 11' 8.00" 12' 5.50" 233 58 Live Replacement Uniform (PLF) Top 11' 8.00" 12' 5.50" 560 0 Snow Replacement Uniform (PLF) Top 11' 8.00" 12' 5.50" 435 431 Live Point (LBS) Top 0' 4.63" 5 501 Live Point (LBS) Top 0' 4.63" 1695 0 Snow 1 2 12 5 8 12 5 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 2.628" 10349# -- 2 12' 5.500" Wall N/A N/A 2.173" 8557# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 4011# 4967# 3615# 2 4000# 3271# 3104# Design spans 11' 8.250" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 25047.'# 38167.'# 65% 6.23' Total Load D+0.75(L+S) Shear 7121.# 13622.# 52% 11.49' Total Load D+0.75(L+S) TL Deflection 0.4203" 0.5844" L/333 6.23' Total Load D+0.75(L+S) LL Deflection 0.2676" 0.3896" L/524 6.23' Total Load 0.75(L+S) Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2018.9 [Build 16] kmBeamEngine 2018.9.0.1 Materials Database 1572 RosemundBrownElkins - Level 6 9-10-19 9:14am 2 of 4 All product names are trademarks of their respective owners Copyright (C) 2018 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB5 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 14.4 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 14' 0.00" 280 70 Live Replacement Uniform (PLF) Top 0' 0.00" 14' 3.44" 200 107 Live Replacement Uniform (PLF) Top 14' 0.00" 25' 8.00" 274 68 Live Replacement Uniform (PLF) Top 14' 3.44" 26' 5.50" 200 107 Live Replacement Uniform (PLF) Top 25' 8.00" 26' 5.50" 274 68 Live 1 2 3 4 9 0 0 9 0 0 8 5 8 26 5 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 2502# -- 2 9' 0.000" Wall N/A N/A 1.756" 6913# -- 3 18' 0.000" Wall N/A N/A 1.676" 6598# -- 4 26' 5.500" Wall N/A N/A 1.500" 2344# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 1854# 648# 2 5039# 1874# 3 4829# 1769# 4 1746# 598# Design spans 8' 7.375" 9' 0.000" 8' 0.875" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 4658.'# 21774.'# 21% 4.26' Odd Spans D+L Negative Moment 5795.'# 21774.'# 26% 9' Adjacent 1 D+L Shear 3032.# 9476.# 31% 8.57' Adjacent 1 D+L TL Deflection 0.0753" 0.4307" L/999+ 4.26' Odd Spans D+L LL Deflection 0.0597" 0.2872" L/999+ 4.69' Odd Spans L Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2018.9 [Build 16] kmBeamEngine 2018.9.0.1 Materials Database 1572 RosemundBrownElkins - Level 6 9-10-19 9:14am 3 of 4 All product names are trademarks of their respective owners Copyright (C) 2018 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB14 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 14.4 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 8' 0.00" 353 88 Live Replacement Uniform (PLF) Top 0' 0.00" 11' 8.00" 233 58 Live Replacement Uniform (PLF) Top 8' 0.00" 11' 8.00" 353 84 Live Replacement Uniform (PLF) Top 11' 8.00" 12' 5.50" 555 182 Live Replacement Uniform (PLF) Top 11' 8.00" 13' 0.00" 676 208 Live Replacement Uniform (PLF) Top 12' 5.50" 13' 0.00" 559 183 Live Replacement Uniform (PLF) Top 13' 0.00" 20' 8.25" 559 183 Live Replacement Uniform (PLF) Top 13' 0.00" 20' 8.25" 676 212 Live Replacement Uniform (PLF) Top 20' 8.25" 24' 5.00" 380 133 Live Replacement Uniform (PLF) Top 20' 8.25" 24' 5.00" 453 152 Live Replacement Uniform (PLF) Top 24' 5.00" 28' 3.00" 252 99 Live Replacement Uniform (PLF) Top 24' 5.00" 28' 3.00" 325 117 Live Replacement Uniform (PLF) Top 28' 3.00" 34' 0.00" 325 117 Live Replacement Uniform (PLF) Top 28' 3.00" 34' 0.00" 442 146 Live Point (LBS) Top 0' 4.63" 2581 942 Live Point (LBS) Top 8' 1.50" 0 121 Live Point (LBS) Top 11' 8.00" 2581 942 Live Point (LBS) Top 12' 10.50" 0 121 Live Point (LBS) Top 20' 6.75" -65 0 Snow Point (LBS) Top 20' 6.75" 569 404 Live Point (LBS) Top 24' 3.50" 0 57 Live Point (LBS) Top 28' 1.13" -58 -97 Snow Point (LBS) Top 33' 7.38" 35 10 Snow 1 2 3 4 5 8 8 0 8 8 0 8 8 0 8 0 0 34 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.565" 6161# -- 2 8' 8.000" Wall N/A N/A 3.073" 12099# -- 3 17' 4.000" Wall N/A N/A 4.221" 16620# -- 4 26' 0.000" Wall N/A N/A 2.571" 10124# -35# 5 34' 0.000" Wall N/A N/A 1.500" 3508# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 4825# 0# 1337# 2 9324# 8# 2774# 3 12488# -48# 4133# 4 7575# -80# 2549# 5 2717# 24# 791# Design spans 8' 3.375" 8' 8.000" 8' 8.000" 7' 7.375" CS Structure™ 2018.9 [Build 16] kmBeamEngine 2018.9.0.1 Materials Database 1572 RosemundBrownElkins - Level 6 9-10-19 9:14am 4 of 4 All product names are trademarks of their respective owners Copyright (C) 2018 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 10901.'# 21774.'# 50% 12.57' Even Spans D+L Negative Moment 13410.'# 21774.'# 61% 17.33' Adjacent 2 D+L Shear 7394.# 9476.# 78% 16.9' Adjacent 2 D+L TL Deflection 0.1601" 0.4333" L/649 12.88' Even Spans D+L LL Deflection 0.1328" 0.2889" L/782 12.99' Even Spans L Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives