6 Garfield - Revised Plans - to include fire setbacks
76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Coleman D. Larsen, SE, PE office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com May 10, 2023 Revised May 31, 2023 Posigen Solar 280 Moody Street Ludlow, MA 01056 Re: Engineering Services Serrano Residence 6 Garfield Avenue, Florence MA 10.400 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: Prefabricated wood trusses at 24” on center. All truss members are constructed of 2 x 4 dimensional lumber. Roof Material: Composite Asphalt Shingles Roof Slope: 30 degrees Attic Access: Accessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 PSF • Dead Load o Existing Roofing and framing = 7 sf o New Solar Panels and Racking = 3 f o TOTAL = 10 • Live Load = 20 psf (reducible) – 0 psf at locations of solar panels • Ground Snow Load = 40 psf • Wind Load based on ASCE 7-10 o Ultimate Wind Speed = 117 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2015 International Residential Code, including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent Ecofasten installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a #12 lag screw is 176 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on two screws with a minimum penetration depth of 2 ½ ”, the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using two #12 lag screws with a minimum of 2 ½ ” embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48” on center. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2015 IRC, current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Very truly yours, Scott E. Wyssling, PE MA License No. 50507 MA COA No. 001629764 Signed 5/31/2023 AERIAL VIEWABBREVIATIONS A AMPERE AC ALTERNATE CURRENT BLDG BUILDING. CONC CONCRETE C COMBINER BOX D DISTRIBUTION PANEL DC DIRECT CURRENT EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRICAL METALLIC TUBING GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED I CURRENT Imp CURRENT AT MAX POWER INVS INVERTERS Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD BEARING WALL MIN MINIMUM (N) NEW NEC NATIONAL ELECTRIC CODE NIC NOT IN CONTRACT NTS NOT TO SCALE OC ON CENTER P PANEL BOARD PL PROPERTY LINES PV PHOTOVOLTAIC PVC POLYVINYL CHLORIDE S SUBPANEL SCH SCHEDULE SS STAINLESS STEEL SSD SEE STRUCTURAL DIAGRAMS STC STANDARD TESTING CONDITIONS SWH SOLAR WATER HEATER TYP TYPICAL UON UNLESS OTHERWISE NOTED UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT 3R NEMA 3R, RAIN TIGHT W WATT POI POINT OF INTERCONNECTION ELECTRICAL NOTES 1. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 2. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 3. A NATIONALLY-RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH NEC. 250.97, 250.92(B) 5. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER NEC. 690.31(E). 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 7. MODULE FRAMES SHALL BE GROUNDED AT THE UL-LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 8. ALL EXPOSED METAL PARTS (MODULE FRAMES, BOXES, ETC.) SHALL BE GROUNDED USING UL LISTED LAY-IN LUGS LISTED FOR THE PURPOSE. 9. MODULE FRAMES AND POSTS SHALL BE ELECTRICALLY CONTINUOUS WITH ATTACHED RAIL. 10. THE DC GROUNDING ELECTRODE CONDUCTOR SHALL BE SIZED ACCORDING TO NEC. 250.166(B) & 690.47. AHJ: HAMPSHIRE COUNTY UTILITY: NATIONAL GRID VICINITY VIEW COVER SHEET NTS APPLICABLE CODE PV-1 PV-2 PV-3 PV-4 PV-5 PV-5.1 INDEX COVER SHEET SITE PLAN ATTACHMENT PLAN ATTACHMENT DETAIL THREE-LINE DIAGRAM SAFETY LABELS MODULE DATASHEET INVERTER DATASHEET OPTIMIZER DATASHEET MOUNTING SYSTEM DATASHEET ILSCO TAP CONNECTOR DATASHEET UL 2703 GROUND & BONDING CERTIFICATION ELECTRICAL NOTES PV-6 PLACARD PV-7 BILL OF MATERIAL MOUNTING SYSTEM ENGINEERING LETTER GENERAL NOTES 1. THIS SYSTEM IS GRID-INTERTIED VIA A UL-LISTED POWER-CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. ALL INVERTERS AND ARRAYS ARE NEGATIVELY GROUNDED. 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED. JOB NUMBER: P-019521 UTILITY: NATIONAL GRID RACKING: ECOFASTEN ROCKIT SMART SLIDE RAILLESS OWNER: ACCOUNT NUMBER : 92613-77010 DESCRIPTION: DESIGNED BY:REV: STAMP: PAGE NAME: SCALE: PV-1.0 DATE: 5/31/2023 MARY SERRANO, RESIDENCE DC SIZE:10.40 kW AC SIZE:10.00 kW ANNUAL PRODUCTION: 8,045 kWH 6 GARFIELD AVE FLORENCE MA 01062 MARY SERRANO MODULES: (26) SILFAB SOLAR SIL-400 HC+ POSIGEN SOLAR 280 Moody St., Ludlow, MA 01056 LICENSES MA ELECTRICAL LICENSE ELC. #100105-EL-MR KARAN RANAINVERTER: (1) SOLAREDGE SE10000H-US OPTIMIZER: (26) SOLAREDGE OPTIMIZER S440/P505 UTILITY CUSTOMER’S NAME:MARY E SERRANO TOTAL ROOF AREA : 1132.29 sq.ft TOTAL AREA COVERED BY ARRAY (%) : 49.01 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL FIRE CODE 2021 INTERNATIONAL RESIDENTIAL CODE 2015 INTERNATIONAL ENERGY CODE 2018 NATIONAL ELECTRIC CODE 2023 Signed 5/31/2023 AC INV MSP M 2 1 SD JB JB FIRE SETBACK 18" FIRE SETBACK 18" 18" 18" 3' 3' N E W S JOB NUMBER: P-019521 UTILITY: NATIONAL GRID RACKING: ECOFASTEN ROCKIT SMART SLIDE RAILLESS OWNER: ACCOUNT NUMBER : 92613-77010 DESCRIPTION: DESIGNED BY:REV: STAMP: PAGE NAME: SCALE: PV-2.0 DATE: 5/31/2023 MARY SERRANO, RESIDENCE DC SIZE:10.40 kW AC SIZE:10.00 kW ANNUAL PRODUCTION: 8,045 kWH 6 GARFIELD AVE FLORENCE MA 01062 MARY SERRANO MODULES: (26) SILFAB SOLAR SIL-400 HC+ POSIGEN SOLAR 280 Moody St., Ludlow, MA 01056 LICENSES MA ELECTRICAL LICENSE ELC. #100105-EL-MR KARAN RANAINVERTER: (1) SOLAREDGE SE10000H-US OPTIMIZER: (26) SOLAREDGE OPTIMIZER S440/P505 UTILITY CUSTOMER’S NAME:MARY E SERRANO LEGEND: STRING #1 - 13 MODULES STRING #2 - 13 MODULES PLOT/SITE PLAN 3/16" = 1'-0" (E) UTILITY METER INV MSP M (E) MAIN SERVICE PANEL AC DISCONNECT INVERTER OBSTRUCTION MODULE JUNCTION BOX AC JB SD SERVICE DISCONNECT GARFIELD AVEFOHROOF SECTION(S): SLOPE: 30 MODULE: 14 AZIMUTH: 205 SLOPE: 30 MODULE: 12 AZIMUTH: 25 1 2 STRING'S NOTE: 6 INCHES GAP BETWEEN SHINGLES & TOP OF PANELS. ARRAY AREA ROOF ROOF TYPE # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) TOTAL AREA COVERED BY ARRAY (%) #1 ASPHALT SHINGLE 14 298.82 1132.29 26.39 49.01 #2 ASPHALT SHINGLE 12 256.13 1132.29 22.62 FIRE CODE OFFSET ROOF ACCESS POINT Signed 5/31/2023 Signed 5/31/2023 12' 1'-5"31'-9"14'-10" 48' FIRE SETBACK 18"18" 3' 12' 3'-4"31'-9"11" 36' 3' 18" FIRE SETBACK 18" JOB NUMBER: P-019521 UTILITY: NATIONAL GRID RACKING: ECOFASTEN ROCKIT SMART SLIDE RAILLESS OWNER: ACCOUNT NUMBER : 92613-77010 DESCRIPTION: DESIGNED BY:REV: STAMP: PAGE NAME: SCALE: PV-3.0 DATE: 5/31/2023 MARY SERRANO, RESIDENCE DC SIZE:10.40 kW AC SIZE:10.00 kW ANNUAL PRODUCTION: 8,045 kWH 6 GARFIELD AVE FLORENCE MA 01062 MARY SERRANO MODULES: (26) SILFAB SOLAR SIL-400 HC+ POSIGEN SOLAR 280 Moody St., Ludlow, MA 01056 LICENSES MA ELECTRICAL LICENSE ELC. #100105-EL-MR KARAN RANAINVERTER: (1) SOLAREDGE SE10000H-US OPTIMIZER: (26) SOLAREDGE OPTIMIZER S440/P505 UTILITY CUSTOMER’S NAME:MARY E SERRANO TOTAL PENETRATION COUNT: 61 ATTACHMENT PLAN ARRAY#2 ARRAY #1 2" X 4" 24"OC ROOF PITCH 30o ARRAY PITCH 30o ROOF AZIMUTH 205o ARRAY AZIMUTH 205 o ROOF MATERIAL ASPHALT SHINGLE TOTAL NO OF PENETRATION 27 ARRAY #2 2" X 4" 24"OC ROOF PITCH 30o ARRAY PITCH 30o ROOF AZIMUTH 25o ARRAY AZIMUTH 25 o ROOF MATERIAL ASPHALT SHINGLE TOTAL NO OF PENETRATION 34 ARRAY#1 1/4" = 1'-0" ROOF TRUSS COUPLINGS ATTACHMENT OBSTRUCTION LEGEND FIRE CODE OFFSET TRUSS PROFILE TRUSS SPACING TRUSS PROFILE TRUSS SPACING Signed 5/31/2023 JOB NUMBER: P-019521 UTILITY: NATIONAL GRID RACKING: ECOFASTEN ROCKIT SMART SLIDE RAILLESS OWNER: ACCOUNT NUMBER : 92613-77010 DESCRIPTION: DESIGNED BY:REV: STAMP: PAGE NAME: SCALE: PV-4.0 DATE: 5/31/2023 MARY SERRANO, RESIDENCE DC SIZE:10.40 kW AC SIZE:10.00 kW ANNUAL PRODUCTION: 8,045 kWH 6 GARFIELD AVE FLORENCE MA 01062 MARY SERRANO MODULES: (26) SILFAB SOLAR SIL-400 HC+ POSIGEN SOLAR 280 Moody St., Ludlow, MA 01056 LICENSES MA ELECTRICAL LICENSE ELC. #100105-EL-MR KARAN RANAINVERTER: (1) SOLAREDGE SE10000H-US OPTIMIZER: (26) SOLAREDGE OPTIMIZER S440/P505 UTILITY CUSTOMER’S NAME:MARY E SERRANO FRAME SECTION NTS ATTACHMENT DETAIL ROCKIT MOUNT ASPHALT SHINGLE SKIRT 2.5" MIN. EMBED.2.5" MIN. EMBED. 2.5" MIN. E M B E D . 2" X 4" TRUSS @ 24" O.C. ATTACHMENT DETAIL Scale: NTS SOLAR PV ARRAY SECTION VIEW Scale: NTS 1 ASPHALT SHINGLE #12 LAG BOLT OR STRUCTURAL SCREW WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER #12 LAG BOLT OR STRUCTURAL SCREW WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER ASPHALT SHINGLE SILFAB SOLAR SIL-400 HC+ ROCKIT MOUNT SILFAB SOLAR SIL-400 HC+ ROCKIT MOUNT SILFAB SOLAR SIL-400 HC+ #12 LAG BOLT OR STRUCTURAL SCREW WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER 2 ECOFASTEN ROCKIT SMART SLIDE RAILLESS 30°ROOF SECTION 130°SILFAB SOLAR SIL-400 HC+ Signed 5/31/2023 SOLAREDGE OPTIMIZER S440/P505 POWER OPTIMIZERS JUNCTION BOX STRING-1 STRING-2 SOLAREDGE OPTIMIZER S440/P505 POWER OPTIMIZERS 13 SILFAB SOLAR SIL-400 HC+ 13 SILFAB SOLAR SIL-400 HC+ 2 1 1 (N) SOLAREDGE SE10000H-US INVERTER AC DC RAPID SHUTDOWN SWITCH 3 (N) 60 A FUSED AC DISCONNECT WITH 60 A FUSES 4 UM(E) 100A / 2P SERVICE DISCONNECT (E) UTILITY METER (E) 125A RATED MAIN LUG PANEL 1PH, 120/240V 60HZ EXISTING WIRE RUN THROUGH CONDUIT (E) MAIN BREAKER ENCLOSURE (E) 100A / 2P MAIN BREAKER G N (N) LOAD SIDE TAP VIA UL LISTED CONNECTORS TO UTILITY UNDERGROUND FEED INVERTER CHARACTERISTICS - SOLAREDGE SE 10000H-US MAX OUTPUT POWER 10000 W SYSTEM OPERATING VOLTAGE 400 V MAX CONTINOUS OUTPUT CURRENT 42 A MAX INPUT VOLTAGE 480 V SYSTEM SHORT CIRCUIT CURRENT 15 A MAX EFFICIENCY 99 % 60V 15A 440W DC MAX INPUT VOLTAGE 80 V MAX OUTPUT CURRENT 15A OPTIMIZER CHARACTERISTICS SOLEREDGE P505/S440 DC INPUT POWER 505W 8MINIMUM STRING LENGTH 6 25MAXIMUM STRING LENGTH 25 AMBIENT TEMPERATURE SPECS RECORD LOW TEMP -14° AMBIENT TEMP (HIGH TEMP 2%)33o CONDUIT HEIGHT 1.0" ARRAY TOP TEMP 65° CONDUCTOR TEMPERATURE RATE 90° NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 4-6 7-9 10-20 PERCENT OF VALUES .80 .70 .50 JOB NUMBER: P-019521 UTILITY: NATIONAL GRID RACKING: ECOFASTEN ROCKIT SMART SLIDE RAILLESS OWNER: ACCOUNT NUMBER : 92613-77010 DESCRIPTION: DESIGNED BY:REV: STAMP: PAGE NAME: SCALE: PV-5.0 DATE: 5/31/2023 MARY SERRANO, RESIDENCE DC SIZE:10.40 kW AC SIZE:10.00 kW ANNUAL PRODUCTION: 8,045 kWH 6 GARFIELD AVE FLORENCE MA 01062 MARY SERRANO MODULES: (26) SILFAB SOLAR SIL-400 HC+ POSIGEN SOLAR 280 Moody St., Ludlow, MA 01056 LICENSES MA ELECTRICAL LICENSE ELC. #100105-EL-MR KARAN RANAINVERTER: (1) SOLAREDGE SE10000H-US OPTIMIZER: (26) SOLAREDGE OPTIMIZER S440/P505 UTILITY CUSTOMER’S NAME:MARY E SERRANO NTS THREE-LINE DIAGRAM METER NUMBER: 51160919 CONDUIT TO BE AL EMT AND CONDUIT DIA. IS MINIMUM WIRE QTY WIRE TAG #CONDUIT WIRE TYPE STRING WATTAGE OPERATING VOLTAGE ADJUSTMENT FACTOR : TEMP RATING: WIRE AMP TEMP DE-RATE: WIRE OCPD: GRND SIZE WIRE GAUGE: 90° WIRE FROM: ARRAY TO JUNCTION BOX1 2 PV WIRE =STRING AMPS 1.25 GRND WIRE TYPE BAREIN AIR 3 THWN-2AL/EMT-1"THWN-2INVERTER TO AC DISCONNECT = =42A NECX X 1.25X JUNCTION BOX TO INVERTER THWN-290°THWN-2 1.25X / = MAX AMPS 4005200 13.00 16.25A 16.25A 52.50A = = = = / /4005200 13.00 MAX. SYSTEM VOLTAGE: 480 480 240 AL/EMT-1" 4 THWN-2 THWN-2AC DISCONNECT TO POI =42A 1.25X 52.50A=240AL/EMT-1" WIRE MATERIAL COPPER COPPER COPPER COPPER #102 3 #6 #104 3 #6 x x =38.4A40A0.96 1.0075A 72.0Axx= x x40A =30.72A0.80 1.00 1.0075A 72.0Axx= #6 #10 #8 #8 0.96 0.96 0.96 90° 90° NOTE:-THE OPTIMIZER IS SELECTED AS PER SITE. MANUFACTURER & MODEL NO. MAX. POWER-POINT CURRENT (IMP) MAX. POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) 11.10 AMPS 36.05 VOLTS 43.02 VOLTS 11.58 AMPS NOM. MAX. POWER AT STC (PMAX)400 WATT MODULE SPECIFICATION SILFAB SOLAR SIL-400 HC+ PHOTOVOLTAIC SYSTEM DC SYSTEM SIZE (kW) NOMINAL AC VOLTAGE 240V AC SYSTEM SIZE (kW)10.000 TOTAL NUMBER OF MODULES 26 10.400 UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D). CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). ALL BOS COMPONENTS WITHIN 10 FT OF UTILITY METER. BACKFEED FUSE SIZING MAX. CONTINUOUS OUTPUT 42A @ 240V 42 X 1.25 =52.50AMPS 60A FUSES - OK ALL BOS COMPONENTS WITHIN 10 FT OF UTILITY METER DISCONNECTS 240V RATED CURRENT MAX RATED VOLTAGE 60 1QUANTITY CONDUIT LENGTH EQUIPMENTS INVERTER TO AC DISCONNECT APPROX 3 ft AC DISCONNECT TO POI APPROX 5 ft LENGTH 3'5' JOB NUMBER: P-019521 UTILITY: NATIONAL GRID RACKING: ECOFASTEN ROCKIT SMART SLIDE RAILLESS OWNER: ACCOUNT NUMBER : 92613-77010 DESCRIPTION: DESIGNED BY:REV: STAMP: PAGE NAME: SCALE: PV-5.1 DATE: 5/31/2023 MARY SERRANO, RESIDENCE DC SIZE:10.40 kW AC SIZE:10.00 kW ANNUAL PRODUCTION: 8,045 kWH 6 GARFIELD AVE FLORENCE MA 01062 MARY SERRANO MODULES: (26) SILFAB SOLAR SIL-400 HC+ POSIGEN SOLAR 280 Moody St., Ludlow, MA 01056 LICENSES MA ELECTRICAL LICENSE ELC. #100105-EL-MR KARAN RANAINVERTER: (1) SOLAREDGE SE10000H-US OPTIMIZER: (26) SOLAREDGE OPTIMIZER S440/P505 UTILITY CUSTOMER’S NAME:MARY E SERRANO GROUNDING NOTES 1 2 3 4 5 6 7 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 & 690 INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 "GROUNDING AND BONDING" WHEN USED WITH PROPOSED PV MODULE. PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY-IN LUGS. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. NTS ELECTRICAL NOTES NOTES : 1.MATING CONNECTORS SHALL COMPLY WITH NEC 690.33. 2.SOLAR EDGE SYSTEM MEETS REQUIREMENTS FOR PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM (PVRSS), AS PER NEC 690.12(B). 3.THE SPECIFIED OPTIMIZER CAN BE SUBSTITUTED WITH A P400, P405, P505, P401, OR P485. THESE OPTIMIZERS HAVE AN INPUT VOLTAGE WINDOW WIDE ENOUGH TO ACCOMMODATE THE OUTPUT VOLTAGE RANGE OF THE MODULE AT THE DESIGN TEMPERATURES, HAVE A MAX INPUT CURRENT RATING THAT IS ABOVE THE MAX OUTPUT CURRENT OF THE MODULE, AND A MAX POWER INPUT THAT IS ABOVE THE RATED POWER OUTPUT OF THE MODULE. 4.DC PV CONDUCTORS ARE NOT SOLIDLY-GROUNDED. NO DC PV CONDUCTOR SHALL BE WHITE- OR GRAY-COLORED 5.ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(A) AND PART III OF ARTICLE 250 AND EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45. THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO NEC 690.47(A) AND NEC 250.169. THE DC GROUNDING ELECTRODE SHALL BE SIZED ACCORDING TO NEC 250.166 AND INSTALLED IN COMPLIANCE WITH NEC 250.64. 6.MAX DC VOLTAGE OF ARRAY FIXED BY THE INVERTER AT 380V REGARDLESS OF TEMPERATURE. THE MAX DC VOLTAGE OF THE MODULE AT -15°C IS 53.2V (-15°C - 25°C) X -0.138V/C + 47.7V = 53.2V). 7.POINT-OF-CONNECTION IS ON THE SUPPLY SIDE OF SERVICE DISCONNECT, INSIDE PANELBOARD ENCLOSURE USING UNUSED TERMINALS, TERMINALS THAT ARE SUITABLE FOR DOUBLE LUGGING, OR USING OTHER LOCALLY-APPROVED METHODS AND HARDWARE, IN COMPLIANCE WITH NEC 705.12(A). THE PANELBOARD SHALL HAVE SUFFICIENT SPACE TO ALLOW FOR ANY TAP HARDWARE AS REQUIRED BY NEC 110.3 AND NEC 312.8(A) 8.PV SYSTEM DISCONNECT SHALL BE VISIBLE KNIFE-BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY, THE DISCONNECT SHALL BE LOCATED WITHIN 10 FT OF ILSCO (ILSCO FOR TAP). DISCONNECT SHALL BE GROUPED IN ACCORDANCE WITH NEC 230.72 AC INV MSP M SD JB JB N E W S JOB NUMBER: P-019521 UTILITY: NATIONAL GRID RACKING: ECOFASTEN ROCKIT SMART SLIDE RAILLESS OWNER: ACCOUNT NUMBER : 92613-77010 DESCRIPTION: DESIGNED BY:REV: STAMP: PAGE NAME: SCALE: PV-6.0 DATE: 5/31/2023 MARY SERRANO, RESIDENCE DC SIZE:10.40 kW AC SIZE:10.00 kW ANNUAL PRODUCTION: 8,045 kWH 6 GARFIELD AVE FLORENCE MA 01062 MARY SERRANO MODULES: (26) SILFAB SOLAR SIL-400 HC+ POSIGEN SOLAR 280 Moody St., Ludlow, MA 01056 LICENSES MA ELECTRICAL LICENSE ELC. #100105-EL-MR KARAN RANAINVERTER: (1) SOLAREDGE SE10000H-US OPTIMIZER: (26) SOLAREDGE OPTIMIZER S440/P505 UTILITY CUSTOMER’S NAME:MARY E SERRANO NTS PLACARD POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: CAUTION DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: NEC 690.56(B)&(C), [NEC 705.10])FRONT OF HOME6 GARFIELD AVE FLORENCE MA 01062 PV ARRAY MAIN DISTRIBUTION UTILITY DISCONNECT INVERTER & RAPID SHUTDOWN DC DISCONNECT SWITCH AC DISCONNECT SERVICE DISCONNECT JOB NUMBER: P-019521 UTILITY: NATIONAL GRID RACKING: ECOFASTEN ROCKIT SMART SLIDE RAILLESS OWNER: ACCOUNT NUMBER : 92613-77010 DESCRIPTION: DESIGNED BY:REV: STAMP: PAGE NAME: SCALE: PV-7.0 DATE: 5/31/2023 MARY SERRANO, RESIDENCE DC SIZE:10.40 kW AC SIZE:10.00 kW ANNUAL PRODUCTION: 8,045 kWH 6 GARFIELD AVE FLORENCE MA 01062 MARY SERRANO MODULES: (26) SILFAB SOLAR SIL-400 HC+ POSIGEN SOLAR 280 Moody St., Ludlow, MA 01056 LICENSES MA ELECTRICAL LICENSE ELC. #100105-EL-MR KARAN RANAINVERTER: (1) SOLAREDGE SE10000H-US OPTIMIZER: (26) SOLAREDGE OPTIMIZER S440/P505 UTILITY CUSTOMER’S NAME:MARY E SERRANO NTS SAFETY LABELS LABEL 5 EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES.[NEC 705.12(B)(2)(3)(c)] LABEL 3 PLACED ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(B)(2)(3)(c)] *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON THE ELECTRICAL DIAGRAM PAGE. JUNCTION BOX OR COMBINER BOX MAIN SERVICE PANEL AC DISCONNECT EXISTING SUB PANEL (IF WHERE POINT OF INTERCONNECTION IS MADE) PV COMBINER SUBPANEL - IF USED TO COMBINE PV OUTPUT CIRCUITS AC DC INVERTER (S) INTEGRATED DC DISCONNECT 2 8 6 9 5 (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) 7 1 1 1 5 (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) 7 3 LABELING DIAGRAM: LABEL 7 AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(D)(2)] LABEL 9 SIGN LOCATED ON OR NO MORE THAN 3FT FROM INITIATION DEVICE [NEC 690.56(C)(2)]. LABEL 8 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(A)] LABEL 1 PLACED ON THE MAIN DISCONNECTING MEANS FOR THE PV SYSTEM. [NEC 690.13(B)] LABELING NOTES: 1.LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2.LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3.MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4.LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21] 5.LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] 3 4 1 LABEL 4 PLACED ON EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES [NEC 705.10(C)] 2 3 4 1 LABEL 2 FOR PV DISCONNECTING MEANS WHERE THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN POSITION. [NEC 690.13(B)] WARNING! TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION !WARNING EQUIPMENT IS FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. ELECTRIC SHOCK HAZARD MAIN PHOTOVOLTAIC SYSTEM DISCONNECT WARNING! POWER SOURCE OUTPUT . DO NOT RELOCATE THIS OVERCURRENT DEVICE. WARNING!DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC POWER SOURCE TURN RAPID SHUTDOWN SWICH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN MAXIMUM DC VOLTAGE OF PV SYSTEM LABEL 6: DC DISCONNECT PER CEC 690.53 LABEL LOCATION: MAIN SERVICE DISCONNECT (PER CODE: CEC 705.30(D)) CAUTION! PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED ##### Racking 40 10 2011021 2011020 3012020 2099012 RI COUPLING AL LBK RI MOUNT AL BLK GF-1 FLASHING GLV BLK 8X10 ARRAY SKIRT 80 in 35mm 54 2011024 RI COMP SLIDE AL BLK 54 54 2 N/A GROUNDING LUG Bill Of Materials MARY SERRANO 6 GARFIELD AVE FLORENCE MA 01062 Electrical Equipment QTY 26 1 26 1 2 Part # SILFAB SOLAR SIL-400 HC+ SOLAREDGE SE10000H-US (240V) SOLAREDGE OPTIMIZER S440/P505 SE-GSM-R05-US-S1 Junction Box Description SILFAB SOLAR SIL-400 HC+ Solar Modules SOLAREDGE SE10000H-US (240V) Inverter(s) SOLAREDGE OPTIMIZER S440/P505 Optimizers SolarEdge GSM w/ 5 Year Plan Junction Box Breakers and Fuses 1 AC Disconnect, 60A, 240VAC, 2-Pole60A FUSED AC Disconnect 2 Tap Connectors Tap Connectors 1 60A Fuses General 60A Fuses 216 3016017 LAG SCREW SS .313X4" W/BW SIL-400 HC+ SILFABSOLAR.COM * Chubb provides error and omission insurance to Silfab Solar Inc. RELIABLE ENERGY. DIRECT FROM THE SOURCE. Designed to outperform. Dependable, durable, high-performance solar panels engineered for North American homeowners. SILFAB SOLAR INC. 800 Cornwall Ave Bellingham WA 98225 USA T +1 360.569.4733 info@silfabsolar.com SILFABSOLAR.COM 1770 Port Drive Burlington WA 98233 USA T +1 360.569.4733 240 Courtneypark Drive East Mississauga ON L5T 2Y3 Canada T +1 905.255.2501 F +1 905.696.0267 Silfab - SIL-400-HC+-20221017No reproduction of any kind is allowed without permission. Data and information is subject to modifications without notice. © Silfab Solar Inc., 2022. Silfab Solar® is a registered trademark of Silfab Solar Inc. ELECTRICAL SPECIFICATIONS 400 Test Conditions STC NOCT Module Power (Pmax)Wp 400 298 Maximum power voltage (Vpmax)V 36.05 33.50 Maximum power current (Ipmax)A 11.10 8.90 Open circuit voltage (Voc)V 43.02 40.35 Short circuit current (Isc)A 11.58 9.34 Module efficiency %20.2%18.8% Maximum system voltage (VDC)V 1000 Series fuse rating A 20 Power Tolerance Wp 0 to +10 Measurement conditions: STC 1000 W/m² • AM 1.5 • Temperature 25 °C • NOCT 800 W/m² • AM 1.5 • Measurement uncertainty ≤ 3% Sun simulator calibration reference modules from Fraunhofer Institute. Electrical characteristics may vary by ±5% and power by 0 to +10W. TEMPERATURE RATINGS Temperature Coefficient Isc +0.064 %/°C Temperature Coefficient Voc -0.28 %/°C Temperature Coefficient Pmax -0.36 %/°C NOCT (± 2°C)45 °C Operating temperature -40/+85 °C WARRANTIES Module product workmanship warranty 25 years** Linear power performance guarantee 30 years ≥ 97.1% end 1st yr ≥ 91.6% end 12th yr ≥ 85.1% end 25th yr ≥ 82.6% end 30th yr SHIPPING SPECS Modules Per Pallet:26 or 26 (California) Pallets Per Truck 32 or 31 (California) Modules Per Truck 832 or 806 (California) CERTIFICATIONS Product UL 61215-1:2017 Ed.1***, UL 61215-2:2017 Ed.1***, UL 61730-1:2017 Ed.1***, UL 61730- 2:2017 Ed.1 ***, CSA C22.2#61730-1:2019 Ed.2***, CSA C22.2#61730-2:2019 Ed.2***, IEC 61215-1:2016 Ed.1***, IEC 61215-2:2016 Ed.1***, IEC 61730-1:2016 Ed.2***, IEC 61730-2:2016 Ed.2***, IEC 61701:2020 (Salt Mist Corrosion), IEC 62716:2013 (Ammonia Corrosion), UL Fire Rating: Type 2, CEC Listing*** Factory ISO9001:2015 MECHANICAL PROPERTIES / COMPONENTS METRIC IMPERIAL Module weight 21.3kg ±0.2kg 47lbs ±0.4lbs Dimensions (H x L x D)1914 mm x 1036 mm x 35 mm 75.3 in x 40.8 in x 1.37 in Maximum surface load (wind/snow)*5400 Pa rear load / 5400 Pa front load 112.8 lb/ft2 rear load / 112.8 lb/ft2 front load Hail impact resistance ø 25 mm at 83 km/h ø 1 in at 51.6 mph Cells 132 Half cells - Si mono PERC 9 busbar - 83 x 166 mm 132 Half cells- Si mono PERC 9 busbar - 3.26 x 6.53 in Glass 3.2 mm high transmittance, tempered, DSM antireflective coating 0.126 in high transmittance, tempered, DSM antireflective coating Cables and connectors (refer to installation manual)1350 mm, ø 5.7 mm, MC4 from Staubli 53 in, ø 0.22 in (12AWG), MC4 from Staubli Backsheet High durability, superior hydrolysis and UV resistance, multi-layer dielectric film, fluorine-free PV backsheet Frame Anodized Aluminum (Black) Bypass diodes 3 diodes-30SQ045T (45V max DC blocking voltage, 30A max forward rectified current) Junction Box UL 3730 Certified, IEC 62790 Certified, IP68 rated * Warning. Read the Safety and Installation Manual for mounting specifications and before handling, installing and operating modules. ** 12 year extendable to 25 years subject to registration and conditions outlined under “Warranty” at silfabsolar.com. PAN files generated from 3rd party performance data are available for download at: silfabsolar.com/downloads. *** Certification and CEC listing in progress. December 2022, expected completion.SideBack ViewProfile75.3" [1914mm]1.4" [35mm]1.4" [35mm]1.4" [35mm]0.06" [1.5mm] 0.5" [12mm]0.3" [7mm]0.6" [15mm]40.8" [1036mm]12.1" [307mm]51.2 [1300mm] 12.1" [307mm]Ø0.17" [Ø4.2mm] (x2)Grounding HoleMounting Hole (x4) Drainage Hole (x8)39.2" [996mm]2.4" [60mm]8" [200mm] 53.15"[1350mm] Cable Length C 183 4730 Madison Road, Cincinnati OH 45227-1426 | PH: 513.533.6200 | FAX: 513.871.4084 | www.ilsco.com In Canada:1050 Lakeshore Road East, Mississauga, Ontario, Canada L5E 1E4 | PH: 905.274.2341 | FAX: 905.274.8763 WL H Catalog Figure Wire Range Current Rating Dimensions Torque Bolt Head Number Number Main Tap Volts CU AL L W H Ft. Lbs. Size IPC-1/0-2 3 1/0-8 2-8 300 (480 Grounded Y System)130 100 1-7/32 1-15/32 2-5/16 16 1/2 IPC-4/0-6 2 4/0-4 6-14 600 75 60 1-27/64 1 1-7/8 13 1/2 IPC-4/0-2/0 3 4/0-2 2/0-6 600 195 150 1-21/32 1-7/8 2-7/8 25 1/2 IPC-250-4/0 2 250kcmil-1 4/0-6 600 260 205 1-7/8 2-11/32 3-11/32 30 5/8 IPC-350-4/0 3 350kcmil-4/0 4/0-10 300 (480 Grounded Y System)260 205 1-43/64 2-7/16 3-1/8 25 5/8 IPC-350-350 4 350kcmil-4/0 350kcmil-4/0 300 (480 Grounded Y System)350 280 2-43/64 2-23/32 3-1/4 25 5/8 IPC-500-12 1 500kcmil-250kcmil 10-12 300 (480 Grounded Y System)40 35 1-43/64 2-7/16 3-1/4 25 5/8 IPC-500-250 1 500kcmil-250kcmil 250kcmil-4 600 290 230 2-27/64 2-29/32 3-3/4 55 5/8-11/16 IPC-500-500 1 500kcmil-300kcmil 500kcmil-250kcmil 600 430 350 3-3/16 3-5/8 5 75 7/8-7/8 IPC-750-500 1 750kcmil-500kcmil 500kcmil-350kcmil 600 430 350 3-3/16 3-5/8 5 75 7/8-7/8 KUP-L-Tap® Insulation Piercing Connectors Dual Rated TYPE IPC Features •Body is molded from tough, resilient glass-filled nylon •Compact design •Tin plated copper contact teeth •Insulation piercing •Perforated end tabs •Pre-filled with silicone lubricant •Versatile •Increased safety •Horizontal line grid •Temperature rating 90˚ C Fig. 1 Fig. 2 Fig. 3 Fig. 4 Benefits •Provides high degree of breakage resistance and long dependable use •Saves space •Easily penetrates most types of insulation •No need to strip the conductor which saves installation time •Break out easily by hand •Prevents oxidation and moisture from entering the contact area •Can be used as a splice or tap connector •Contains no external energized parts. Can be installed “hot” on energized conductors providing tap conductor is not under load. •Provides a visual guide for proper installation of conductors All wire sizes, unless noted otherwise, are American Wire Gauge (AWG) Tested to UL 486A/B, UL File E6207 453G LR-296 0 1 EcoFasten Solar LLC 4141 W Van Buren St, Ste 2 Phoenix, AZ 85009 TEL: (877) 859-3947 Attn.: Eco Fasten Solar LLC - Engineering Department Subject: Engineering Certification for the State of Massachusetts Building Codes: 1.ASCE/SEI 7-10 & 7-16 Minimum Design Loads for Buildings and Other Structures, by American Society of Civil Engineers 2.2012, 2015, & 2018 International Building Code 3.2012, 2015, & 2018 International Residential Code 4.AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES 5.Aluminum Design Manual 2010 & 2018, by The Aluminum Association, Inc. 6.ANSI/AWC NDS-2015 & 2018, National Design Specification for Wood Construction, by the American Wood Council Design Criteria: Risk Category II Seismic Design Category = A - E Exposure Category = B, C & D Basic Wind Speed (ultimate) per ASCE 7-16 = 90 mph to 180 mph Ground Snow Load = 0 to 60 (psf) This letter certifies that the loading criteria and design basis for the EcoFasten - RockIt System Span Tables are in compliance with the above codes. If you have any questions on the above, do not hesitate to call. Prepared by: PZSE, Inc. – Structural Engineers Roseville, CA January 13, 2023 PZSE, Inc. – Structural Engineers has provided engineering and span tables for the EcoFasten - RockIt System, as presented in PZSE Report # 2015-05884HG.06.01, "Engineering Certification for the EcoFasten - RockIt System for Gable and Hip Roofs". All information, data, and analysis therein are based on, and comply with, the following building codes and typical specifications: Re: Report # 2015-05884HG.06.01 – EcoFasten - RockIt System for Gable and Hip Roofs EXP. 06/30/2024 PAUL K. ZACHER STRUCTURAL No. 50100 DIGITALLY SIGNED