Loading...
15-014 BP-2023-0415 356 CHESTERFIELD RD COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 15-014-001 CITY OF NORTHAMPTON Permit: Alts Renovations Repair PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2023-0415 PERMISSION IS HEREBY GRANTED TO: Project# CHIMNEY 2023 Contractor: License: Est. Cost: 5295 CORY MCGILL 107658 Const.Class: Exp.Date: 05/25/2023 Use Group: Owner: BREGUET PATRICIA A Lot Size (sq.ft.) Zoning: RR Applicant: CORY MCGILL DBA DONE RIGHT CHIMNEY Applicant Address Phone: Insurance: PO BOX 1054 (413)340-1399 WCV 01525601 WILLIAMSBURG, MA 01096 ISSUED ON: 04/07/2023 TO PERFORM THE FOLLOWING WORK: RE-LINE CHIMNEY, PELLET INSERT INSTALL POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: , 1 II Fees Paid: $65.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Office of the Building Commissioner ~ The Commonwealth of Massachusetts R E C E 1\,,r` w Board of Building Regulations and Standards _�T. FOR Massachusetts State Building Code, 780 CMR� MUlskr'ICIPALITY c23 USE; Building Permit Application To Construct,Repair,Renovate r Demolish a 2- Revised Mcdr 2011 One-or Two-Family Dwelling . This Section For Official Use OnlyA 'TIM 1hr Plr; ;:; Building P it Number: i-- .3 c fj�� Date Applied: v,���. f7i2 4 7 zvz3 Building Official(Print Name) Signature Date SECTION 1: SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 356 Chesterfield Road, Northampton, MA 01053 1.la Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private CI Municipal_ Outside Flood Zone? Municipal 0 On site disposal sy stem ❑ Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Reigt=Dmke 0 Co Circu raks. Northampton,MA 01053 Name(Print) City,State,ZIP 356 Chesterfield Road (413)695-7509 Ben5724@yahoo.com No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction Cl Lxisting Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition 0 Demolition 0 Accessory Bldg. 0 Number of Units Other M' Specify:Chimney re-line,Pellet Insert Install Brief Description of Proposed Work': Level 2 Inspection completed 03/10/2023. To line existing masonry chimney with a 4"stainless steel liner kit.To install(1)Enviro EF2 pellet insert and vent into new stainless steel liner. SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building $5,295.59 1. Building Permit Fee: $ Indicate how fee is determined: 2.Electrical $ ❑ Standard City/Town Application Fee ❑Total Project Cost'(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees: Check No.1X11 Check Amo t: 5 Cash Amount: 6. Total Project Cost: S 5,295.59 0 Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-107568 05/25/2023 Cory McGill License Number Expiration Date Name of CSL Holder List CSL Type(see below) U P.O. Box 1054 No.and Street Type Description Williamsburg, MA 01096 U Unrestricted(Buildings up to 35,000 Cu.ft.) R Restricted 1&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofmg Covering WS Window and Siding SF Solid Fuel Burning Appliances (413) 340-1399 ContactDoneRight©gmail.com I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) #178722 08/27/2024 Cory McGill HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name P.O. Box 1054 ContactDoneRight@gmail.com No.and Street Email address Williamsburg, MA 01096 (413) 340-1399 City/Town, State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ® No 0 SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Cory McGill to act on my behalf,in all matters relative to work authorized by this building permit application. Rrr-Ar F11 i E-ZCtAir - YIC/ 3 Print Owner's Name(Electronic Signature) Date SECTION 7b: OWNER' OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. a Co McGill ` � `,7 L!.S Print Owner's or Author' Agent's Name(Electronic Signature) g g ) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system _ Number of decks/porches Type of cooling system _ Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" City of Northampton 61. ' rs" l Massachusetts wzs`' clt DEPAR224ENT OF BUILDING INSPECTIONS rar r' 212 Main Street • Municipal Building ,, C Northampton, MA 01060 APPLICATION FOR SOLID FUEL APPLIANCE INSTALLATION Property Information Owners Name: Address: 356 Chesterfield Road, Northampton, MA 01053 (No.) (Street Address) Phone: Cell: (413) 695-7509 Email: Ben5724@yahoo.com Owners Signature: Date: Contractor's In ormation A licable Name: Cory McGill Phone: Construction Supervisor's License #: CS-107568 Expiration: 05/25/2023 Home Impr. Contractor License #: 178722 Expiration: 08/27/2024 Stove Information Type of Fuel (check all that apply): Wood Pellet V Coal Location: Living room: Fireplace Freestanding Insert v Manufacturer: Enviro Model: EF2 --- -----------------FOR BUILDING DEPARTMENT USE ONLY-----------------_-_----_-_- Permit# Date Applied: • Total all Fees: $ Building Official: Date Issued: (Print) Signature of Building Official: The Commonwealth of Massachusetts wz Department of Industrial Accidents l i '_01 I, Office of Investigations ei= 1 Congress Street, Suite 100 iil Boston, MA 02114-2017 '14,... www.mass.gov/dia Workers' Compensation Insurance Affidavit: General Businesses Applicant Information Please Print Legibly Business/Organization Name: Done Right Chimney Address:P.O.Box 1054,45 Main Street, Unit B City/State/Zip:Williamsburg, MA 01096 Phone#:(413)340-1399 Are you an employer?Check the appropriate box: Business Type(required): 1.❑■ I am a employer with 3 employees (full and/ 5. ❑■ Retail or part-time).* 6. ❑ Restaurant/Bar/Eating Establishment 2.❑ I am a sole proprietor or partnership and have no 7. ❑ Office and/or Sales(incl. real estate,auto,etc.) employees working for me in any capacity. [No workers' comp. insurance required] 8. ❑Non-profit 3.❑ We are a corporation and its officers have exercised 9. ❑ Entertainment their right of exemption per c. 152, §1(4),and we have 10.0 Manufacturing no employees. [No workers' comp. insurance required]** 11.❑ Health Care 4.❑ We are a non-profit organization, staffed by volunteers, with no employees. [No workers' comp. insurance req.] I2.. Other Services: Chimney&Hearth *Any applicant that checks box##I must also fill out the section below showing their workers'compensation policy information. **If the corporate officers have exempted themselves,but the corporation has other employees,a workers'compensation policy is required and such an organization should check box!!1. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy information. Insurance Company Name:Atlantic Charter Insurance Company Insurer's Address:45 Main Street, Unit B City/State/Zip: Williamsburg, MA 01096 Policy#or Self-ins. Lic. # WCV 01525601 Expiration Date:06/28/2023 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify,under the pains and penalties of perjury that the information provided above is true and correct. Signature: SUlk (�(((J//v Date: Oci I051 a kN3 Phone#: (413) 340-1399 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4. Licensing Board 5.Selectmen's Office 6.Other Contact Person: Phone#: www.mass.gov/dia I N STALLATI O N CLEARANCES TO COMBUSTIBLES - FREESTANDING: When installing this unit on a combustible floor (for example linoleum, hardwood flooring) a non-combustible hearth pad must be under the unit. The pad must extend at least the width of the appliance 22" (55.8 cm) and at least the depth of the appliance plus 9" (22.8 cm) in front of the appliance. Side wall to unit - 6 inches (15 cm) These dimensions are minimum clearances but it is recommended that you ensure sufficient room for Back wall to unit - 1 inches (2.5 cm) servicing, routine cleaning and maintenance. Corner to unit - 1 inches (2.5 cm) Back Wall Door front to edge of floor protection ,� ... a q - 9 inches (22.8 cm) 2" ky ,9) (5 cm) (55 cm) ,;�'d, 36" r, i / ' f (91 cm) (76 30" / Tci o cm) -oo (15.2 cm) `, in '> ii I 1 9' 48" (22.8cm) (122 cm) Floor Protection All/ Figure 4:EF2-1 FS Clearance to Combustibles. Minimum Alcove width - 36 inches (91 cm) Minimum Alcove height - 48 inches (122 cm) Figure 5 :EF2-1 FS Minimum Alcove Size. Minimum Alcove depth - 30 inches (76 cm) CLEARANCES TO COMBUSTIBLES - FIREPLACE INSERT: Refer to Figure 6. r 10"(25.4 cm)Mantel Side wall to unit - 8 inches (20.3 cm) 8" (20.3 cm) Mantel projection - 10 inches (25.4 cm) Mantel to top of unit - 8 inches (20.3 cm) au:a =n Top facing to unit - 8 inches (20.3 cm) -; I Side facing to unit - 9 inches (22.8 cm) g,-9„yy jam(_ o Floor protection - 9 inches (22.8 cm) cl(22.8 cm) __._07r1 on either side and to the front must ram` ' Tir f be protected by non-combustible material. // —o �� i Floor Protection;Minimum 9"(22.8 cm)in front of door Figure 6:EF2-I FPI Clearance to Combustibles. 9 r INSTALLATION INSTRUCTIONS Phone:888-900-8106 I � FOR BEST-Flex Models "L", "H", "S", & "E" Fax:888-392 4432 Web:www.NewEn IandChimne Su I co M STAINLESS STEEL CHIMNEY LINERS g Y ppYm I mi 34 Commerce Street,Williston VT 05495 g lir irl BEST-Flex Models 0 11600 iiLI, iiH99 itQ91 Q LiE/3 Be'Sr > > ! Q� FLex New England Supply PRODUCTS STAINLESS STEEL CHIMNEY LINERS BEST-Flex Models"L","H","S",&"E"Stainless Steel Chimney Liners are manufactured by New England Supply Inc.Located in Williston,VT. The BEST-Flex lining system is designed and UL listed to be installed inside masonry chimneys.BEST-Flex liners are used to vent the gases and by-products produced by appliances that burn oil,gas,or solid fuels. All appliances require certain venting specifications and the liner is not to be sized less than specified in the appliance manufacturer's instructions.For the best operation refer to the appliance manufacturer's instructions to determine any special necessities for that specific appliance. The installer must contact the local building and fire code officials for a variety of reasons: • The installation may require special inspection requirements. • Building permits may be required before installation. • Compliance with local building codes.(Authorities with local jurisdiction such as Inspectors,Municiple Building Departments,Fire Departments,and Fire Bureau's have precedence over national codes). For proper results and operation use only materials or components specified in these installation instructions. Using parts or materials not specified may result in undesireable effects. The lining system safety,code compliance,warranty and performance may be compromised if the installation instructions are not followed BEST-Flex Stainless Steel Chimney Liners are tested and listed by Underwriters Laboratories. • In the United States they are tested to UL 1777 and can be installed in NEW&EXISTING masonry chimneys. • In Canada they are tested to ULC S635 and are to be installed in EXISTING masonry chimneys. PRODUCT INFORMATION FOR BEST-Flex CHIMNEY LINERS • The BEST-Flex Stainless Steel Flexible Chimney liner is designed to reline existing chimneys or to be used as a liner in new construction. Manufactured with the highest quality,mill certified alloy.BEST-Flex Stainless Steel Flexible Chimney Liner has a high acid fighting capability. Listed by UL Laboratories to UL 1777&ULC S635 standards for zero clearance installation.BEST-Flex can be used to vent wood,wood pellet,coal,non- condensing gas and oil,making it the choice for venting all standard efficiency installations.UL listed BEST-Flex is available in 3"to 12"diameters (13"above is not listed)to cover a wide range of requirements found in the field today. • The unique manufacturing systems used to make BEST-Flex utilizes a continuous strip of stainless steel,7-ply interlocked and crimped to produce a gas and water tight lining system of superior strength and durability.BEST-Flex can be curved to go around offsets in chimneys and can be factory ovalized to custom sizes to fit most any installation requirement.Unless specified by the manufacturer,the liner is not to be field ovalized. The corrugated construction allows for expansion&contraction during the heat-up&cool-down periods,which removes any stresses on the system. • BEST-Flex can be insulated with either a vermiculite based poured insulation or with a foil-faced ceramic wool blanket to meet UL 1777&ULC S635 standards for chimney exteriors with zero clearance to combustibles. • BEST-Flex Stainless Steel Chimney Liner comes with a Life Time Warranty for all fuels,with appliance efficiencies at 83 percent or lower. MATERIALS REQUIRED FOR BEST-Flex STAINLESS STEEL LINER INSTALLATION: Liner Model-"L","H", "S",&"E" TT/TB-Two piece or one piece tee TEC-Tee Cap EA/EF-15°-90°elbow C/CC-Coupler , Screws/Rivets OPTION A "�' `, OPTION B TP-Top Plate TPCC-Liner Cap TC-Top Clamp • IC> OR TPC-Top Plate401.6b OR SC-Storm Collar la CL-Liner Cap(square/round) INSULATION MATERIALS REQUIRED(if applicable) Part# Description, ,V_ LI2 Liner Insulation 1/2"Foil Faced Ceramic Wool Blanket LM Liner Mesh Protective Wire Mesh Sleeve " ' , FT(2", 3") Aluminum Foil Tape ''� , LMC(large/small) Mesh Clamp - BMIX BEST Mix Ali® `-.� ' • Al 16 .„,„4 Phone:888-900-8106 Fax:888-392-4432 • I�� � Web:www.NewEnglandChimneySupply.com New England Supply 34 Commerce Street,Williston VT 05495 1.)CHIMNEY PREPARATION&INITIAL INSPECTION Before any liner can be installed the existing chimney must meet proper construction and code requirements: • The chimney must be between 10-ft high(min)and 100-ft(max)in height. • The chimney must have a wall thickness of 4-inch min(nominal)solid masonry unit. • The chimney must project at least 3-ft over the point of roof penetration,and at least 2-ft higher than any point of any structure within a 10-ft radius. • If the mass of the chimney is constructed within the structure a 2-in minimum,unobstructed air space,must surround the chimney mass to any combustible material.If the chimney is constructed on the outside of the structure,1-in of unobstructed air space must be maintained between the chimney mass and all other combustible materials. • When the chimney breaks the plane of a floor,ceiling,or other horizontal or vertical structure,fire stops of a non-combustible material must be used. • The installer must verify the above with all local&national codes as required. • If the correct clearances cannot be verified due to regional factors the liner must be installed with a UL listed insulation material. • Any appliance that burns a liquid fuel cannot be attached to a chimney liner made to vent a solid fuel burning appliance. • The connection pipe between the appliance and the chimney liner must have proper clearances to combustibles. This can be determined by the appliance manufacturer's installation instructions,the national building code,the local building code,or whichever factor takes precedence. • The chimney must be cleaned comprehensively to remove all deposits of soot,creosote,or glazed creosote before any liner is installed.A full inspection must be done to determine if the chimney is structurally sound.If the existing system is found not to be in compliance with applicable building code and/or manufacturers installation instructions,the liner shall not be installed until appropriate steps have been taken in order to bring the chimney or vent into compliance with the applicable code and/or manufacturer's instructions. Note:Installing a lining system into an existing chimney or vent does not,in any way,upgrade the resulting relined system and make it suitable for any applications that require a vent or chimney of a higher temperature handling capability,an altemative fuel,or any other more sever service than the original chimney or vent in which it is installed. . CHIMNEY CONNECTORS AND VENT CONNECTORS 2.)SIZING THE CORRECT CHIMNEY LINER DIAMETER • Any heating appliance connected to the lining system must not System man 3.5M.(eomm41005m .ariiemaaMm 2M.(5)nm1 -+� kwwnm debwma hor day li er to co bustibamdl2R(005 mm)Mick MC315. M have a flue outlet size larger than the liner area at its smallest +: +2M(305mm) horn deyaner%oombueablee.Freddy ts(ASTMc015. point,unless a qualified person has sized the liner to suit the —C r - d0"d' Ste a )w Clay am"""°and�.M node«equivalent), r ml,umm%N.(10 ran)cod etrkeeea.enea run horn outer suteoe T B a of did,wait,hut not beyond,the Inner surface ddbnney flue appliance — Ins(and alma be limey cernented In place. • For sizing a liner used for gas and oil burning appliances refer t ` : - aear.n,12r( mm) to N.F.P.A 54 for gas and N.F.P.A 31 for oil.Also refer to the seeder ,w mi 12M ldo5mnl '' C appliance manufacturer's instructions.Liners that are incorrectly bton°°"°° d 2nn sized for the appliance can lead to poor draft,excessive condensation,and creosote build-up inside the lining system. Mnwmm chimney clearance kan System O.Solid-insulated rwtea%dis,aat chimney length of the same m.em.ymwww et Inonpo9U"d _ sw4'" insiademeter se the chime/canedorarid hieing 1 in Please call New England Supply Inc.should you have any ee pldee 2ln.(5t non) d..an^e \ °p 1■ aM.(229 avn) (25mm)armored eaoueon silo,a 99 chimney%M.(th ) questions about sizing a liner. 'Factory. tuift NoneduaM air space between the outer coop of de For sizing a liner used for solid fuel burning appliances the cross ' "le"'"leO cement ont Thee ndo'"echimney shelbenlunwimme • '- inside of ctdnxwyrueand shnobesealed to the Due section area of the liner shall not be less than the cross section a end to the brick masonry penetration with non-water-soluble dens _ I use areaway refractory cement.Supports shall be securely fastened to wall ••••,,,,,•,•• mlra pemm surfaces on all sIdee. area ofthe appliance outlet collar.Unless specified by the ��}�,,a,re wNurely Fasteners between e�s end lroarneeylengm shed not appliance the cross section area of the flue shall not be more than e"�" )mM sir � ' �°"'" penetrate Md chimney lner. three(3)times the cross section area of the appliance outlet collar. dymp,2;, Clearance:9 M.(229 mm) Solid fuel burning fireplace liners should be a minimum of one- Sheer red wows twelfth(1/12)the square inches compared to the square inches of the fireplace opening.This one-twelfth(1/12)number can Wrenn d�.nn„•d.amme-t—+ srwmC.sne«meltsMawy�eeamr,minimum 20 gauge[0.024in. stag%ports'ivarree es �w, (0.61 ramp in 906,hiss,with a ventilated amble.minmum vary based on height of the chimney along with other calculating 2In(5t e,a) - two eadrwwlr 24 gauge(0.024 in.(0.61nm))n thickness,haying two lh factors.Call New England Supply Inc.if you have any questions. �� ewt'M as.ea) (25mr000 channels,separ ted'mre try aet111T= of 6 in.(152 ram)of glass fiber insulation.Opening elan be covered, 11f�1\Y S Chim and tnende supported with a sheet stew support,mm:num 24 gauge t\1`�� connector (Esupports p in. haammbe securely%caned to well surfaces on all sides 3.)DETERMINE IF THE LINER SIZED IN STEP#2 WILL FIT INTO �1 _ and shag bew:stilem and hold dtmneysection.Fasteners used et52 nsm. chimney penetrate hoonoy flue finer. THE CHIMNEY twowanistlesk 0„oe N , mm toaeare ee°ti°n shall no • The BEST-Flex Stainless Steel Chimney Liner can be installed Aber insulalke "n,P5man: .„w,,,,d,„^,,,,,V(�' '6M(152nen( inside the existing flue tile or the flue tile can be removed.It d wrwlnmwt m NFM 211 sl.xewwnpew is critical that the correct size liner will actually fit into the flue. Chimney construction and flue offsets may change the physical minimum dismay carve*to shoo semi supports and System D.sad-insrtales,listed,anwmry-bam chimney length with aninside size of the interior of the chimney.It is best to test the smallest ° ttl••2 M.(51 mm) damwer21n.(51ram)lager than the chimney connector end having SnaM Mew 1 in(25 ram)on mom w ireulalion,serving as a pass-wagh fore abate point of the chimneyinterior before trying to install the chimneyr�wesab �ef""~nd•mo)2M.(5tmin) wa"sheet weeld inner/he,ado Of 2oodan24 gauge 10.024 in. rY 9 , 0.61 mm)I thickness,with a minimum 2 M.(51 mm)a space be wean the Ceimn 01 . tM(25^,4•••ro, outer wall w chi section and combisbles liner.Lower a short piece of the correct size liner down the „ �.,,_.,mawnimlwgM Minimum length wdnmwypeenppan.toa;zm.nosmm),Chimney chimney to see if it will fit through,or a liner guide cone.If the sodion concentric with and spaced 1 in.(25 ram)away horn conned°,by ch., means d sheet stew support plates on both ends of chimney section. chimney liner needs to be insulated extra space around the liner aill w""`. ' Opening shad be covered,and chimney secfisnsupported on both sides with yn M.n� cw,00yw91 sheet steel supports of mknmum 24 gauge 10.024 in.(0.61 ram))thickness is required.If a round liner configuration will not fit the liner can be ._. Cwwwy wgM Supports shall be securely fastened to wall sorlaces on all sides Air spew 2 M.151 mml end shell be sized to It end hold WFnney section.Fasteners used formed into an oval shape to fit at the factory. However an oval %ee«ay V Sheer sloe � ie a, ,e to secure dumneysedion shall tint penetrate chimney the Nner. liner will change the cross section area and a larger liner may be corua�2t' Clearance,2 in.(51 ram) needed.Please call New England Supply Inc.with any questions. Note AN clearances and thicknesses are minimums;larger clearances and thdnesses are permitted. 4.)INSTALLING THE BEST-FLEX STAINLESS STEEL CHIMNEY LINER • Thimbles must be in the proper location to maintain the required clearance to combustibles from the connector pipe to the appliance. The liner length is determined by measuring from the lowest thimble(if more than one)to the top of the chimney.Add approximately Six(6)inches to attach the crown and top hardware.Cut the liner to the desired length. • If a liner is not long enough a coupler may be used to join two pieces of liner.Attach the Coupler to the liner with the affixed band,or stainless steel screws(Male end down when applicable). • Attach the Tee Body to the liner with the affixed band,or stainless steel screws.If the liner needs to be insulated with a ceramic wool blanket,install the blanket at this point. Attach the Tee Cap to the Tee Body at this point. • Expand the draw band on the Tee Snout completely,slide the Tee Snout into the thimble with the draw band centered in the flue.Lower the liner