Loading...
32C-047 (28)Architect's Field Report Contractor ® Owner ❑ Architect ® Consultant ❑ Field ❑ Building Inspector ® Other ❑ Project: Tattoo Afterlife 110 Pleasant Street Northampton, MA 01060 Contract: Renovation Date: 7/24/2014 Weather: sunny, clear Est. % of Completion: 80% Work in Progress: Drywall. wiring Workers Present: 2 Carpenters, 2 electricams Field Report No. 3 Project No. 14-05-02 Time: 12:25 to 12:50 Temperature: 79 of Conformance w/ Schedule Observations: 1. Most of the drywall is completed and 2/3 appears to be finish coated. 2. Wall insulation and ceiling insulation are completed. 3. Drywall taping is in progress in the back rooms. 4. Finish wiring is following closely behind drywall. 5. The RTU curb is installed on top of the opening which has been boxed out using double 2X8's both ways on joist hangers. 6. Half of the break room has been converted into 2 more tattoo stations, reportedly approved by the inspectors. Items to Verify: Cut sheet on the RTU Information or Action Required: Report By: RSB Roy S. Brown Architects 85 Chilson Road - Wilbraham, Massachusetts 01095 -phone 413.596.2360 - fax 413.596.2360 - email: rsba85@yahoo.com Architect's Field Report Contractor ® Owner ❑ Architect ® Consultant ❑ Field ❑ Building Inspector ® Other ❑ Project: Tattoo Afterlife 110 Pleasant Street Northampton, MA 01060 Contract: Renovation Date: 6/27/2014 Weather: sunny Est. % of Completion: Work in Progress: Insulation, wiring, plumbing Field Report No. 2 Project No. 14-05-02 Time: 12:15 to 1:00 Temperature: 84 o F Conformance w/ Schedule Workers Present: 1 Carpenter, 2 electricians, 4 plumbers left at noon. Observations: 1. When the plumber fan the vent stack through the roof it was discovered that there was no insulation in the roof. So the contractor is now insulating the roof with R-30 batts and vapor barrier. 2. All the new interior concrete is poured and covered with curing paper. Aprons are also poured at the doors 3. Most of the new copper is now in place. The toilet room to remain will have its fixtures replaced as well as the few pieces of non -conforming piping. 4. Rough wiring is nearly complete and a rough inspection will be called for early next week. 5. Framing is ready for an inspection. Items to Verify: Information or Action Required: Cut sheet for RTU. Location at masonry wall intersection and 2 X 8's, 16" o.c. spanning 10'-611 . Report By: RSB Roy S. Brown Architects 85 Chilson Road - Wilbraham, Massachusetts 01095 -phone 413.596.2360 - fax 413.596.2360 - email: rsba85@yahoo.com Architect's Field Report Contractor Q Owner ❑ Architect FX� Consultant ❑ Field ❑ Building Inspector ❑X Other ❑ Project: Tattoo Afterlife 110 Pleasant Street Northampton, MA 01060 Contract: Renovation Date: 6/ 12/2014 Weather: light mist Est. % of Completion: Work in Progress: Demolition, metal studs, plumbing Workers Present: 2 Carpenters Field Report No. 1 Project No. 14-05-02 Time: 1:15 to 1:40 Temperature: 65 o F Conformance w/ Schedule Observations: 1. Most of the demolition has been completed. 2. The under slab rough plumbing has also been done and is ready for inspection. 3. A fair amount of the slab was also uneven and some of it very thin. A number of boulders were removed as was additional slab. 4. Metal stud partitions for the message rooms have been installed as well as wood blocking to secure the door bucks. 5. The side exterior door has been installed. 6. The pavement has been sawcut for concrete aprons at the exterior doors. Items to Verify: Information or Action Required: Report By: RSB Bev S. Brown Archftects 85 Chilson Road -Wilbraham, Massachusetts 01095 -phone 413.596.2360 - fax 413.596.2360 - email: rsba85@yahoo.com CMVE SEP 3 0 2014 D 1 v S. Brown MOWS !!fp - Wilbraham, Massachusetts 01095 N Plumbing m �bipn g 1, " Northampton d 3.596.2360 - fax 413,596.2360 email rsba85@yahoo.com In accordance with Section 107.6.2.2 of the Massachusetts State Building Code, 1, Roy S. Brown being a registered architect, certify that I have reviewed all of the shop drawings, product submittals, and specifications for the Building Renovations for Tattoo Afterlife 110 Pleasant Street Northampton, MA 01060 and that to the best of my knowledge such shop drawings, product submittals, and specifications conform to the provisions of the said Code, all acceptable architectural practices and all applicable laws and ordinances. And, further, that I have supervised the inspection of the construction and Submitted reports as required by Section 107.6.2.2.3 of the Code. Rov S. Brown 9/17/20 14 (Sigrlalulv)