Towsley 125 Locust St TA3977-M1 Drawing - 062322aTOWSLEY ASSOCIATES CONSULTING ENGINEERS EAST LONGMEADOW, MA PETER McNULTY DPW ADMINISTRATION BUILDING 125 LOCUST ST - NORTHAMPTON, MA M-1 OF 1TA-21-432 WAT KCC 1/4"=1'-0"06/24/22 NEW VENTILATION SYSTEM FLOOR PLAN / DETAILS & SCHEDULES / GENERAL NOTES SCALE: 1/4"=1'-0" VENTILATION FLOOR PLAN CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT CONDENSING UNIT DUCTLESS UNIT DUCTLESS UNIT DUCTLESS UNIT DUCTLESS UNIT DUCTLESS UNIT DUCTLESS UNIT 4"Ø CD 40 CFM4"ØVD 4"Ø CD 40 CFM4"ØVD4"ØVD 4"Ø CD 40 CFM 4"ØVD 4"Ø CD 40 CFM 6" x 6" 6" x 6"5"Ø4" x 6"ELECTRIC BASEBOARD RADIATION 5"Ø ER 60 CFM 5"Ø4" x 6"5"Ø ER 60 CFM RAIN LEADER COMPUTER ROOM STAFF DISCONTINUE TOILET EXHAUST FANS 8" x 6"VD5"Ø CD 70 CFM 5"Ø VD6" x 6"10" x 6"WAITINGRECEPTION VD 4"Ø4"Ø ER 40 CFM VD 4"Ø4"Ø ER 40 CFM 6" x 6"VD VD 8" x 6"8" x 6" LIGHTS (TYP.) 5"Ø CER 70 CFM VD 5"Ø 8" x 6"VD 4"Ø 4"Ø CD 45 CFM VD4"Ø 4"Ø ER 45 CFM OFFICE BOARD ROOM 12" x 6"12" x 7"TYPICAL DUCT BRANCH TAKE-OFF: SEE DETAIL10" x 6"VD 4"Ø 4"Ø CD 45 CFM 10" x 8"VD INSTALL ALL DUCTWORK ABOVE CEILING12" x 10"TURNING VANES TYPICAL: SEE DETAIL4"Ø4"Ø ER 45 CFM VD 12" x 8"12" x 9" VD DUCTLESS UNIT RELOCATION OF EXISTING AIR COOLED CONDENSING UNIT TO INSTALL NEW ENERGY RECOVERY UNIT BY OWNER TWO (2) 12" x 10" DUCTS DN AT WALL HEAT RECOVERY VENTILATOR UNIT (ERV): REFER TO SCHEDULE. MOUNTED ON NEW 8" HIGH CONCRETE PAD. MOUNT UNIT ON ANGLE IRON FRAME 2'-0"± ABOVE GRADE. 12" x 10" SUPPLY AND EXHAUST THROUGH WALL DN TO UNIT. TRANSITION DUCTWORK TO SUPPLY AND EXHAUST OF UNIT. INSTALL FLEX. CONN. AT UNIT EXHAUST AIR WEATHER HOOD OUTDOOR AIR WEATHER HOOD CUT, PATCH, AND SEAL OUTSIDE WALL TO INSTALL DUCTWORK DEPARTMENT OFFICE 5 KW ELECTRIC DUCT HEATER 12" x 10"VD 20" x 4" A M1 A M1 5"ØVD 5"ØVD6" x 6"5" x 4"6" x 6"VD 5"Ø CD 50 CFM 5"Ø CD 50 CFM FINANCIAL ADMINISTRATION DPW DIRECTOR ENGINEERING DRAFTING CITY ENGINEER 5"Ø CD 60 CFM 5"Ø VD VD 8" x 6"VAULT 5"Ø 4"Ø10" x 6"12" x 6" VD VD 5"Ø CD 60 CFM 4" x 4"4"Ø CD 40 CFM 5"Ø5"Ø ER 50 CFM5" x 4"5"Ø ER 50 CFM 5"Ø VD 5"Ø VD 5"Ø ER 60 CFM 6" x 6"6" x 6"5" x 4"VD 4"Ø4"Ø ER 40 CFM VD5"Ø ER 60 CFM 6" x 6" 5"Ø VD 8" x 8"12" x 6" GENERAL NOTES 1. AVOID ELECTRICAL CONDUIT, CABLE WIRING, AND REFRIGERANT PIPING ABOVE SUSPENDED CEILINGS WHEN INSTALLING SUPPLY AND EXHAUST DUCTWORK. 2. CEILING GRID TO BE REMOVED AND REPLACED BY OTHERS. 3. CUT, PATCH, AND FIRE SEAL SHEET ROCK WALLS ABOVE CEILING TO INSTALL DUCTWORK (REFER TO SECTION "B" - "B"). 4. WHERE REQUIRED, RELOCATE ELECTRICAL CONDUIT, CABLE OR REFRIGERANT PIPING ABOVE CEILING TO INSTALL NEW DUCTWORK AT NO COST TO THE OWNER. 5. CUT, PATCH, AND SEAL WATER TIGHT OUTSIDE BRICK WALL TO INSTALL NEW SUPPLY AND EXHAUST DUCTWORK (REFER TO DETAIL). 6. HANG NEW SUPPLY AND EXHAUST DUCTWORK ABOVE CEILING FROM ROOF JOISTS. REPAIR PLASTIC SHEATHING (APPROX. 14" CLEAR ABOVE SUSPENDED CEILINGS). 7. RELOCATION OF EXISTING AIR COOLED CONDENSING UNIT TO INSTALL NEW ENERGY RECOVERY UNIT BY OWNER. 8. MOUNT NEW ERV UNIT ON 8" HIGH CONCRETE PAD APPROX. 4'-6" x 4'-6". 9. SUPPLY DIFFUSERS TITUS "TMSA". EXHAUST REGISTERS TITUS "50 FL". 10. INSULATE OUTSIDE DUCTWORK AND ALL CONCEALED SUPPLY DUCTWORK ABOVE CEILING: REFER TO SPECIFICATIONS. 11. ELECTRICAL DUCT HEATER MOUNTED IN 12" x 10" SUPPLY DUCT 5 KW / 120 / 240 V 1 PH 24 VOLT CONTROL WITH SCR CONTROL LIMIT SWITCH / MANUAL RESET HIGH LIMIT AND AIR FLOW SENSOR. 12. ELECTRICAL NOTES - WIRE ELECTRIC DUCT HEATER TO SPARE #18 IN EXISTING ELECTRICAL PANEL #2. WIRE HEAT RECOVERY UNIT TO SPARE #24 IN EXISTING ELECTRICAL PANEL #2. 13. MAXIMUM USE OF FLEX DUCT IS 10'-0". 14. REFER TO SPECIFICATIONS FOR PROJECT PHASING. COORDINATE WITH DPW ENGINEERING STAFF. 15. EXACT LOCATION OF SUPPLY DIFFUSERS AND EXHAUST REGISTERS TO BE DETERMINED IN THE FIELD. ELECTRIC HEATING COIL ROOF JOISTS 10" x 12"10" x 12"EXISTING DUCTLESS UNIT TO REMAIN FLEX. CONN. CUT, PATCH, AND SEAL OUTSIDE WALL (SEE DETAIL) HEAT RECOVERY UNIT ON ANGLE IRON FRAME EXHAUST HOOD 2'-0" HIGH ANGLE IRON FRAME OR UNISTRUT 8" HIGH CONCRETE PAD SCALE: 1/4"=1'-0" SECTION "A" - "A" ROOF 2' x 2' SUSPENDED CEILING & GRID SECURE FRAME TO CONCRETE PAD SECURE UNIT TO ANGLE IRON FRAME OR UNISTRUT NOTE 8 FLEXIBLE DUCTWORK (TYPICAL) NOTE 6 NOTE 9 NOTE 3 NOTE 1 NOTE 10 NOTE 3 B M1 B M1 ELECTRIC PANEL UTILITY ROOM NOTE 1 NOTE 9 NOTE 2 NOTE 10 NOTE 9 NOTE 9 NOTE 3 NOTE 2 NOTE 6 NOTE 1 WALKWAYNOTE 3 NOTE 6 NOTE 2 NOTE 7 NOTE 5FLEX CONNSCALE: 1/4"=1'-0" SECTION "B" - "B" TYP. WALL PENETRATION 2' x 2' SUSPENDED CEILING & GRID ROOF JOISTS 6" x 10" DUCT CUT, PATCH, AND SEAL WALLS ABOVE CEILING: TYPICAL AT ALL PENETRATIONS EXISTING WALL CEILING SPACE APPROX. ± 16"FLOOR COUNTER NOTE 3 NOTE 3 DUCTLESS UNIT NOTE 3 INSTALL DUCTWORK BETWEEN VAULT CEILING AND ROOF STRUCTURE TTO ELECTRIC DUCT HEATER REFER TO DUCT BRANCH TAKE-OFF DETAIL ELECTRIC DISCONNECT WIRE TO SPARE #24 IN P-24" X 5"10" x 6" 8" x 8" BUILDING ELECTRIC SHUT OFF MAIN DISTRIBUTION PANEL PANEL P-1 PANEL P-2 NOTE 12 EXISTING CONDUIT CEILING FAN CEILING FAN CEILING FAN CEILING FAN SUPPLY EXHAUST EXHAUSTSUPPLYNOMINAL CFM SUPPLY CFM EXHAUST UNIT NO. 1 580 620 O U T D O O R E N E R G Y R E C O V E R Y U N I T S C H E D U L E EXTERNAL SP IN WC 1.0 VOLTAGE 120 / 240 1 PH / 60 Cy SUPPLY & EXHAUST MOTORS HP 1/2 MCA AMPS 8.9 MOP AMPS 15 MFG. MODEL NO. BASED ON GREENHECK CONSTANT VOLUME UNIT ERV-10-20L-VG WEIGHT 300 LBS. REMARKS FURNISH UNITS WITH STANDARD EQUIPMENT, TIME CLOCK, DUCT HEATER, PROVIDE FACTORY START-UP SERVICE OUTLET, 2" MERV13 FILTERS. REFER TO SPECIFICATIONS FOR MORE DETAILS. SOUND LEVEL: 65.1 DBA / SONES 14 NOTE: RENWAIRE OR AIR EXCHANGER CONSIDERED EQUAL VD L WMAIN DUCT TAPERED CONNECTION 45° (IF MAIN DUCT IS RECTANGULAR) OR CONICAL CONNECTION (IF MAIN DUCT IS ROUND) L = 1/4 W: 4" MIN. BRANCH DUCT EXHAUST AIR SUPPLY AIR SCALE: NONE DUCT BRANCH TAKE OFF DETAIL 2" RADIUS FOR DUCTS 19" AND WIDER 1" RADIUS FOR DUCTS UP TO 18" WIDE 4" RADIUS FOR DUCTS 19" AND WIDER 2" RADIUS FOR DUCTS UP TO 18" WIDE SCALE: NONE DUCT ELBOW AND VANE DETAILS 1-1/8" MIN.1-1/8" FOR DUCTS UP TO 18" WIDE 2-1/4" FOR DUCTS 19" AND WIDER SAME RADIUS AS VANES SHEET METAL SCREWS BOTH SIDES OF EVERY OTHER BLADE INSULATED DUCT, PITCH DOWNWARD AT EXTERIOR TO SHED WATER, 2% PITCH MIN., TYP.: STRUCTURAL ANGLE FOR EACH 4" WYTHE OF MASONRY - L 4x3 1 2" X 5 16". LOOSE ANGLE LINTELS NEW AZEK OR EQUAL TRIM SURROUND, INSET, SEALED TO DUCT & MASONRY EXISTING WALL BARRIER SYSTEM: CUT EXISTING WALL BARRIER, INSERT NEW LINTEL FLASHING BEHIND BARRIER, ADHERE TO EXISTING PLYWOOD MASONRY WEEP TUBING ATOP FLASHING, 2 MIN. EACH OPENING, TYP.: SEALANT JOINT W/ CLOSED-CELL BACKER ROD: NEW 20 OZ RED COPPER FLASHING PAN AT BASE, FLAIR SIDES UP 1" TREMCO DYMONIC FC CAULK OR EQUAL W/ BACKER, TYP.: NEW 3 4" X 4" AZEK OR EQUAL FRAME AROUND PERIMETER OF ENTIRE DUCT CUT DRYWALL, PLYWOOD & MASONRY, REMOVE AND SECURE TEMPORARILY AS REQUIRED APPROX. (2) 14" x 14" OPENINGS MEASURE IN FIELD SCALE: NONE TYPICAL WALL FLASHING / LINTEL DETAIL