jb_0103397_00_b_acad_b_01 SINDEX
ABBREVIATIONS ELECTRICAL NOTES
VICINITY MAP
JURISDICTION NOTES
REV BY DATE COMMENTS
REV A NAME DATE COMMENTS
REV B UAI 12/21/2022 LAYOUT AND ESS LOCATION UPDATED PER INSTALLATION
****
****
****
LICENSE GENERAL NOTES
Front Of House
(E) DRIVEWAY
SV
SV
SV
SV
SV
SV
SV
Pitch8/12MP
1
Pitch8/12MP2
P
i
t
c
h
8
/
1
2
MP3Pitch8/12MP4Pitch8/12MP5Pitch8/12MP6Pitch8/12MP7Scale:1/16" = 1'
SITE PLAN
01'32'16'
LEGEND
MP3
34° (8:12)
320
34° (8:12)
320
Comp Shingle 2 Stories
MP2
34° (8:12)
140
34° (8:12)
140
Comp Shingle 2 Stories
MP1
34° (8:12)
230
34° (8:12)
230
Comp Shingle 2 Stories
MP4
34° (8:12)
140
34° (8:12)
140
Comp Shingle 2 Stories
MP5
34° (8:12)
50
34° (8:12)
50
Comp Shingle 2 Stories
MP6
34° (8:12)
140
34° (8:12)
140
Comp Shingle 2 Stories
NTS
TYPICAL PV SIDE VIEWSV
Scale: 1 1/2" = 1'
STANDOFFS1
GNDGND
W
L2
L1
N
EGC
GND
N
240V
Product 1
EGC
DC-
DC+
DC-
DC+
DC-
DC+
A
DC-
DC+
EGC
DC-
DC+
EGC
DC-
DC+
MP1: 1x6
MP2: 1x4
MP3: 1x10
GD
L2
L1
N
EGC
GND
N
240V
Product 2
EGC
DC-
DC+
DC-
DC+
DC-
DC+
DC-
DC+
A
DC-
DC+
EGC
DC-
DC+
DC-
DC+
EGC
DC-
DC+
MP4: 1x2
MP7: 1x2
MP5: 1x6
MP6: 1x6
GD
A
PV
1
Voc*= VDC Isc = ADC
Vmp = VDC Imp= ADC1
2
Voc*= VDC Isc = ADC
Vmp = VDC Imp= ADC2
3
Voc*= VDC Isc = ADC
Vmp = VDC Imp= ADC3
4
Voc*= VDC Isc = ADC
Vmp = VDC Imp= ADC4
5
Voc*= VDC Isc = ADC
Vmp = VDC Imp= ADC5
6
Voc*= VDC Isc = ADC
Vmp = VDC Imp= ADC6
7
Voc*= VDC Isc = ADC
Vmp = VDC Imp= ADC7
8
Voc*= VDC Isc = ADC
Vmp = VDC Imp= ADC8
9
Voc*= VDC Isc = ADC
Vmp = VDC Imp= ADC9
10
Voc*= VDC Isc = ADC
Vmp = VDC Imp= ADC10
Vmp = VAC Imp= AAC
11
Vmp = VAC Imp= AAC
12
Z
GNDGND
Y
15
12V
V
LICENSEMODULE SPECS
1
PRODUCT SPECSGENERAL NOTESMAIN PANEL SPECS
2
3
AC DC
13
L1NL2
POI
Z
Y
X
W
13
14
15
GNDGND
W
11
12
V
X
14
SOLAR PV SYSTEM
EQUIPPED WITH RAPID
SHUTDOWN
- Address: 329 Rocky Hill Rd
OPERATING VOLTAGE = 240V JB-0103397-00
- Address: 329 Rocky Hill Rd
OPERATING VOLTAGE = 240V JB-0103397-00
- Address: 329 Rocky Hill Rd
OPERATING VOLTAGE = 240V JB-0103397-00
- Address: 329 Rocky Hill Rd
OPERATING VOLTAGE = 240V JB-0103397-00
NEC_2023-690_31_D_2
Per Code:
690.31.D.2
Label Location:
(C)(IC)(CB)
NEC_2023-690_7_D
Per Code:
690.7.D
Label Location:
(DC) (INV)
NEC_2023-705_10
Per Code:
705.10
Label Location:
(MSP)
NEC_2023-690_13_B
Per Code:
690.13.B
Label Location:
(AC) (POI)(DC) (INV)
NEC_2023-690_13_B-3
Per Code:
690.13.B
Label Location:
(DC)(CB)
NEC_2023-705_12_B_2
Per Code:
705.12.B.2
Label Location:
(POI)
NEC_2023-705_12_B_3
Per Code:
705.12.B.3
NEC_2023-705_30_C
Per Code:
705.30.C
Label Location:
(POI)
NEC_2023-690_12_D_2
Per Code:
690.56.C.2
Label Location:
RSD Switch
NEC_2023-690_12_D
Per Code:
690.12.D
Label Location:
(INV)
(POI): Point of Interconnection
(M): Utility Meter
(LC): Load Center
(INV): Inverter With Integrated DC Disconnect
(IC): Interior Run Conduit
(DC): DC Disconnect
(D): Distribution Panel
(CB): Combiner Box
(C): Conduit
(AC): AC Disconnect
Label Set
NEC_2023-408_4
Per Code:
408.4
Label Location:
(BLC)
NEC_2023-220
Per Code:
220
Label Location:
(BLC)
NEC_2023-312_8_A_4
Per Code:
312.8.A.4
Label Location:
(MSP)
NEC_2023-705_30_C-1
Per Code:
705.30.C
Label Location:
(MSP)
NEC_2023-705_12_B_2
Per Code:
705.12.B.2
Label Location:
(POI)
NEC_2023-705_12_B_3
Per Code:
705.12.B.3
NEC_2023-705_30_C-2
Per Code:
705.30.C
Label Location:
(MSP)
NEC_2023-705_10_2
Per Code:
705.10.2
Label Location:
(MSP)
NEC_2023-706_15_C
Per Code:
706.15.C
Label Location:
(MSP)
(MSP): Main Service Panel
(BLC): Backup Load Center
(AC): AC Disconnect
Label Set
DC-
DC+
1
GD
x
x
x
x
x
DC1
·
·
·
·
·
DC1
DC-
DC+
1
GD
TESLA.COM/ENERGY
BACKUP SWITCH
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature –40°C to 50°C (–40°F to 122°F)
Storage Temperature –40°C to 85°C (–40°F to 185°F)
Enclosure Rating NEMA 3R
Pollution Rating PD3
PERFORMANCE SPECIFICATIONS
Model Number 1624171-xx-y
Continuous Load Rating 200A, 120/240V Split phase
Short Circuit Current Rating 22 kA with breaker1
Communication CAN
Product Compatibility Powerwall 2 with Backup Gateway 2,
Powerwall+
Expected Service Life 21 years
Warranty 10 years
COMPLIANCE INFORMATION
Safety Standards USA: UL 414, UL 2735, UL 916
CA Prop 65
Emissions FCC, ICES
2022-03-02
2 Manually overrides the contactor position during a service event.
MECHANICAL SPECIFICATIONS
Dimensions 176 mm x 205 mm x 74 mm
(6.9 in x 8.1 in x 2.9 in)
Weight 2.8 lbs
Meter and Socket Compatibility ANSI Type 2S, ringless or ring type
External Service Interface Contactor manual override2
Reset button
Conduit Compatibility 1/2-inch NPT
1 Breaker size must be equal to or greater than the available fault current.
175.8
204.86
74
The Tesla Backup Switch controls connection to the grid in a
Powerwall system, and can be easily installed behind the utility
meter or in a standalone meter panel downstream of the utility
meter.
The Backup Switch automatically detects grid outages, providing
a seamless transition to backup power. It communicates directly
with Powerwall, allowing home energy usage monitoring from
any mobile device with the Tesla app.
176 mm
205 mm
74 mm
TESLA.COM/ENERGY
POWERWALL+
Powerwall+ is an integrated solar battery system that stores energy from solar production. Powerwall+ has two
separate inverters, one for battery and one for solar, that are optimized to work together. Its integrated design and
streamlined installation allow for simple connection to any home, and improved surge power capability brings whole
home backup in a smaller package. Smart system controls enable owners to customize system behavior to suit their
renewable energy needs.
KEY FEATURES
• Integrated battery, inverter, and system controller for a more compact install
• A suite of application modes, including self-powered, time-based control, and backup modes
• Wi-Fi, Ethernet, and LTE connectivity with easy over-the-air updates
NA 2022-05-06 TESLA.COM/ENERGY
POWERWALL+
COMPLIANCE INFORMATION
PV Certifications UL 1699B, UL 1741, UL 3741, UL 1741 SA, UL
1998 (US), IEEE 1547, IEEE 1547.1
Battery Energy Storage
System Certifications
UL 1642, UL 1741, UL 1741 PCS, UL 1741 SA, UL
1973, UL 9540, IEEE 1547, IEEE 1547.1, UN 38.3
Grid Connection United States
Emissions FCC Part 15 Class B
Environmental RoHS Directive 2011/65/EU
Seismic AC156, IEEE 693-2005 (high)
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature –20°C to 50°C (–4°F to 122°F)8
Recommended Temperature 0°C to 30°C (32°F to 86°F)
Operating Humidity (RH)Up to 100%, condensing
Storage Conditions –20°C to 30°C (–4°F to 86°F)
Up to 95% RH, non-condensing
State of Energy (SoE): 25% initial
Maximum Elevation 3000 m (9843 ft)
Environment Indoor and outdoor rated
Enclosure Type Type 3R
Solar Assembly Ingress Rating IP55 (Wiring Compartment)
Battery Assembly Ingress Rating IP56 (Wiring Compartment)
IP67 (Battery & Power Electronics)
Noise Level @ 1 m < 40 db(A) optimal,
< 50 db(A) maximum
MECHANICAL SPECIFICATIONS
Dimensions 1596 x 755 x 160 mm (62.8 x 29.7 x 6.3 in)
Total Weight 140 kg (310 lb)7
Battery Assembly 118 kg (261 lb)
Solar Assembly 22 kg (49 lb)
Mounting options Floor or wall mount
1Values provided for 25°C (77°F).
2Load start capability may vary.
3Where the DC input current exceeds an MPPT rating, jumpers can be used to
allow a single MPPT to intake additional DC current up to 26 A Imp / 34 A Isc.
4Power factor rating at max real power.
5AC to battery to AC, at beginning of life.
6Cellular connectivity subject to network service coverage and signal
strength.
7The total weight does not include the Powerwall+ bracket, which weighs an
additional 9 kg (20 lb).
8Performance may be de-rated at operating temperatures below 10°C (50°F)
or greater than 43°C (109°F).
NA 2022-05-06
PHOTOVOLTAIC (PV) AND BATTERY ENERGY
STORAGE SYSTEM (BESS) SPECIFICATIONS
Powerwall+ Model Number 1850000-xx-y
Solar Assembly Model Number 1538000-xx-y
Nominal Battery Energy 13.5 kWh
Nominal Grid Voltage (Input / Output)120/240 VAC
Grid Voltage Range 211.2 - 264 VAC
Frequency 60 Hz
Phase 240 VAC: 2W+N+GND
Maximum Continuous Power On-Grid 7.6 kVA full sun / 5.8 kVA no sun1
Maximum Continuous Power Off-Grid 9.6 kW full sun / 7 kW no sun1
Peak Off-Grid Power (10 s)22 kW full sun / 10 kW no sun1
Maximum Continuous Current On-Grid 32 A output
Maximum Continuous Current Off-Grid 40 A output
Load Start Capability 98 - 118 A LRA2
PV Maximum Input Voltage 600 VDC
PV DC Input Voltage Range 60 - 550 VDC
PV DC MPPT Voltage Range 60 - 480 VDC
MPPTs 4
Input Connectors per MPPT 1-2-1-2
Maximum Current per MPPT (Imp)13 A3
Maximum Short Circuit
Current per MPPT (Isc)
17 A3
Allowable DC/AC Ratio 1.7
Overcurrent Protection Device 50 A breaker
Maximum Supply Fault Current 10 kA
Output Power Factor Rating +/– 0.9 to 14
Round Trip Efficiency 90%5
Solar Generation CEC Efficiency 97.5% at 208 V
98.0% at 240 V
Customer Interface Tesla Mobile App
Internet Connectivity Wi-Fi, Ethernet, Cellular LTE/4G)6
PV AC Metering Revenue grade (+/-0.5%)
Protections Integrated arc fault
circuit interrupter (AFCI),
PV Rapid Shutdown
Warranty 10 years
160 mm
1596 mm
755 mm
TESLA.COM/ENERGY
SOLAR SHUTDOWN DEVICE
The Tesla Solar Shutdown Device is a Mid-Circuit
Interrupter (MCI) and is part of the PV system rapid
shutdown (RSD) function in accordance with Article 690
of the applicable NEC. When paired with Powerwall+,
solar array shutdown is initiated by pushing the System
Shutdown Switch if one is present.
650 mm 150 mm
125 mm
250 mm
M4 Screw
M8 Bolt
Nail /
Wood Screw
22 mm
NA 2022-05-06
ENVIRONMENTAL SPECIFICATIONS
Ambient Temperature -40°C to 50°C (-40°F to 122°F)
Storage Temperature –30°C to 60°C (–22°F to 140°F)
Enclosure Rating NEMA 4 / IP65
ELECTRICAL SPECIFICATIONS
Model Number MCI-1
Nominal Input DC Current Rating (IMP)12 A
Maximum Input Short Circuit Current (ISC)15 A
Maximum System Voltage 600 V DC
COMPLIANCE INFORMATION
Certifications UL 1741 PVRSE, UL 3741,
PVRSA (Photovoltaic Rapid
Shutdown Array)
RSD Initiation Method External System Shutdown Switch
Compatible Equipment See Compatibility Table below
MECHANICAL SPECIFICATIONS
Electrical Connections MC4 Connector
Housing Plastic
Dimensions 125 mm x 150 mm x 22 mm
(5 in x 6 in x 1 in)
Weight 350 g (0.77 lb)
Mounting Options ZEP Home Run Clip
M4 Screw (#10)
M8 Bolt (5/16")
Nail / Wood screw
RSD MODULE PERFORMANCE
Maximum Number of Devices per String 5
Control Power Line Excitation
Passive State Normally open
Maximum Power Consumption 7 W
Warranty 25 years
UL 3741 PV HAZARD CONTROL (AND PVRSA) COMPATIBILITY
Tesla Solar Roof and Tesla/Zep ZS Arrays using the following modules are certified to UL 3741 and UL 1741 PVRSA when installed with the Powerwall+ and
Solar Shutdown Devices. See the Powerwall+ Installation Manual for detailed instructions and for guidance on installing Powerwall+ and Solar Shutdown
Devices with other modules.
Brand Model Required Solar Shutdown Devices
Tesla Solar Roof V3 1 Solar Shutdown Device per 10 modules
Tesla Tesla TxxxS (where xxx = 405 to 450 W, increments of 5) 1 Solar Shutdown Device per 3 modules
1
Tesla Tesla TxxxH (where xxx = 395 to 415 W, increments of 5) 1 Solar Shutdown Device per 3 modules
Hanwha Q.PEAK DUO BLK-G5 1 Solar Shutdown Device per 3 modules
Hanwha Q.PEAK DUO BLK-G6+ 1 Solar Shutdown Device per 3 modules
1Exception: Tesla solar modules installed in locations where the max Voc for three modules at low design temperatures exceeds 165 V shall be limited to
two modules between Solar Shutdown Devices.
TESLA.COM/ENERGY
SYSTEM LAYOUTS
Powerwall+ with Backup Switch Installed Behind Utility Meter
Powerwall+ with Backup Switch Installed Downstream of Utility Meter
NA 2022-05-06
TESLA.COM/ENERGY
Powerwall+ with Backup Gateway 2 for Whole Home Backup
Powerwall+ with Backup Gateway 2 for Partial Home Backup
NA 2022-05-06
Tesla Module Datasheet
(TEPV-DS-0011-21)
Tesla Photovoltaic Module
T395H, T400H, and T405H
—
The Tesla module is one of the most powerful residential photovoltaic
modules available and exceeds industry engineering and quality standards.
Featuring our proprietary Zep Groove design, the all-black module mounts
close to your roof for a minimalist aesthetic. Modules are certified to IEC /
UL 61730 - 1, IEC / UL 61730 - 2 and IEC 61215.
Tesla Module Datasheet
(TEPV-DS-0011-21)
T400HT395H T405H
STC NMOTSTC NMOT STC NMOT
400 300.1395 296.3 405 303.8
45.30 42.7245.27 42.69 45.34 42.76
11.14 8.9711.10 8.95 11.17 9.00
37.13 35.2536.88 35.03 37.39 35.46
10.77 8.5110.71 8.46 10.83 8.57
t 20.4t 20.1 t 20.6
1000 W/m2, 25°C, AM1.5
800 W/m2, 20°C, AM1.5, wind speed 1 m/s
+0.04% / °C
-0.34% / °C
-0.27% / °C
4080 Pa | 85 lb/ft2
4080 Pa | 85 lb/ft2
35 mm at 27.2 m/s
6120 Pa | 128 lb/ ft2
6120 Pa | 128 lb/ ft2
132 (6 x 22)
4 mm2 | 12 AWG, 1325 mm | 47.2 in. Length
IP68, 3 diodes
Staubli MC4
0.13 in (3.2 mm) thermally pre-stressed glass
23.5 kg | 51.8 lb
Black Anodized Aluminum Alloy
1890 mm x 1046 mm x 40 mm
74.4 in x 41.2 in x 1.57 in
-40°C up to +85°C
20 A
+/- 5%
Class II
-0 /+5W
45.7 +/- 3 °C
DC 1000 V (IEC/UL)
UL 61730 Type 2
25 years
25 years
0
12 Cell Temp = 25°C
8
4
10
6
2
05040302010Current (A)Voltage (V)
800 W/m2
400 W/m2
1000 W/m2
600 W/m2
200 W/m2
0
450 Cell Temp = 25°C
300
100
400
150
05040302010Power (W)Voltage (V)
800 W/m2
400 W/m2
1000 W/m2
600 W/m2
200 W/m2
350
250
50
200
0
10
05040302010Current (A)Voltage (V)
12
8
2
6
41150 mm | 45.3 in1890 mm | 74.4 in40 +/- 0.5 mm
1.57 +/- 0.020 in
1046 mm | 41.2 in 1325 mm | 47.2 in40 mm / 1.575 in35 mm / 1.378 in
Warranted PmaxYear
98%
86%
80%
252001 10515
85%
90%
95%
Incident Irradiance =
1000 W/m2
Cell Temp=35ºC
Cell Temp=25ºC
Cell Temp=45ºC
Cell Temp=55ºC
Cell Temp=65ºC
Cell Temp=75ºC
Electrical Characteristics
Front Side Design Load
Mechanical Loading
Rear Side Test Load
Power Class
Short Circuit Current, ISC (A)
Max Power, PMAX (W)
Max Power Current, IMP (A)
Test Method
Max Power Voltage, VMP (V)
Open Circuit Voltage, VOC (V)
Module Efficiency (%)
STC
NOCT
Hail Test
Rear Side Design Load
Front Side Test Load
Cell Orientation
Front Cover
Cable
Weight
Junction Box
Frame
Connector
Dimension
Mechanical Parameters
Operational Temperature
Max Series Fuse Rating
VOC & ISC Tolerance
Safety Class
Power Output Tolerance
NOCT
Max System Voltage
Fire Rating
Operation Parameters
At least 98% of nominal power during first year. Thereafter max. 0.5% degradation per
year. At least 93.5% of nominal power up to 10 years. At least 86% of nominal power up
to 25 years.
Linear Power Warranty
Materials and Processing
Extra Linear Power Output
Current vs. Voltage Power vs. Voltage Current vs. Voltage
IV Curves
Temperature Coefficient of Isc
Temperature Coefficient of PMAX (W)
Temperature Coefficient of VOC
Temperature Rating (STC)
Module Specifications
Refer to module and system
installation manuals for
allowable design loads, foot
spacings, and cantilever
specifications.
FLASHING INSERT
ZS COMP DATASHEET 2
Listed to UL 2703 and UL 2582 for Wind Driven Rain
Part #850-1628
SPECIFICATIONS Designed for pitched roofs.
Installs in portrait and landscape orientations.
Engineered for spans up to 72” and cantilevers up to 24”.
ZS Comp has a UL 1703 Class “A” Fire Rating when installed using modules from any
PDQXIDFWXUHUFHUWL¿HGDV³7\SH´RU³7\SH´
Attachment method UL listed to UL 2582 for Wind Driven Rain.
ZS Comp supports 50 psf (2400 Pa) front and up to 72 psf (3450 Pa) rear side design load
rating for Portrait module orientation per UL 2703.
ZS Comp supports 50 psf (2400 Pa) front side and up to 72 psf (3450 Pa) rear side design
load rating for Landscape module orientation.
Engineered for compliance with ASCE 7-05, 7-10, and 7-16 wind load requirements.
Zep wire management products listed to UL 1565 for wire positioning devices.
ZS Comp grounding products are listed to UL 2703 and UL 467.
ZS Comp bonding products are listed to UL 2703.
DESCRIPTION PV mounting solution for composition shingle roofs.
Works with all Zep Compatible Modules.
Auto bonding UL-listed hardware creates structural and electrical bond.
ROOFING SYSTEM SPECIFICATIONS
MOUNTING BLOCK
CAPTURED WASHER LAG
Listed to UL 2703
Part #850-1633
Part #850-1631-002 and #850-1631-004
ZS COMP DATASHEET 3
GROUND ZEP LEVELING FOOT
DC WIRE CLIP HOME RUN CLIP
Listed to UL 1565
Part #850-1510
ARRAY SKIRT END CAP
Listed to UL 2703
Part #850-1511
Listed to UL 2703
Part #850-1613
Listed to UL 2703
Part #850-1608
Listed to UL 2703
Part #850-1606
Listed to UL 2703
Part #850-1586 (Left)
Part #850-1588 (Right)
INTERLOCKSKIRT GRIP
Listed to UL 2703
Part #850-1397
Listed to UL 1565
Part #850-1509
Listed to UL 2703
Part #850-1281
HYBRID INTERLOCK
Wire & Conduit Size Equivalence Table: Copper & Aluminum
1TEZS-DS-0020-21
PV HAZARD CONTROL EQUIPMENT AND COMPONENTS
Function Manufacturer Model No.
Firmware Versions
and Checksums &HUWL¿FDWLRQ6WDQGDUG
3956(0LG&LUFXLW
Interrupter (MCI)Tesla MCI-1 N/A 8/3956(
Inverter or Powerwall+ Tesla
7.6 kW: 1538000 1
3.8 kW: 1534000 1
7.6 kW: 1850000 1
9&($)
9))%((
9&($)
UL 1741, 1998
395663956(
PV Module
+DQZKD4&(//6
Tesla
43($.'82%/.*6&
43($.'82%/.*6&
7HVOD7[[[6[[[ WR
7HVOD7[[[+[[[ WR
N/A UL 1703
UL 61730
39+&6,QLWLDWRU
(PV Inverter)
'HGLFDWHG39V\VWHP$&FLUFXLWEUHDNHURU$&GLVFRQQHFWVZLWFKODEHOHGSHU1(&
requirements.N/A
39+&6,QLWLDWRU
(Powerwall+)
(PHUJHQF\VWRSGHYLFH1,6'/LVWHG(PHUJHQF\6WRS%XWWRQRU(PHUJHQF\6WRS
'HYLFHRU(PHUJHQF\6WRS8QLW
UL 508 or UL 60947 Parts
1, 5-1 and 5-5
1$SSOLHVWRYDULDWLRQVRIWKLVSDUWQXPEHUZLWKVXႈ[RIWZRQXPEHUVDQGRQHOHWWHU
1RWH39+&6LQVWDOODWLRQUHTXLUHPHQWVPD\UHGXFHWKHHႇHFWLYHHTXLSPHQWDQGFRPSRQHQWUDWLQJVEHORZWKHLQGLYLGXDOHTXLSPHQWDQGFRPSRQHQW
3956(UDWLQJVLQRUGHUWRDFKLHYH39+&6VKRFNKD]DUGUHGXFWLRQUHTXLUHPHQWV
PVHCS INSTALLATION REQUIREMENTS
0D[6\VWHP9ROWDJH 600 Vඌඋ
39+&60D[LPXP&LUFXLW9ROWDJH$UUD\,QWHUQDO9ROWDJH$IWHU$FWXDWLRQ165 Vඌඋ (cold weather open circuit)
0D[6HULHV&RQQHFWHG0RGXOHV%HWZHHQ0&,V
([FHSWLRQ7HVOD66HULHV7[[[6PRGXOHVLQVWDOOHGLQORFDWLRQVZKHUHWKHPD[92&IRU
PRGXOHVDWORZGHVLJQWHPSHUDWXUHH[FHHGV9VKDOOEHOLPLWHGWRPRGXOHVEHWZHHQ0&,V
3*
OTHER INSTALLATION INSTRUCTIONS
$Q0&,PXVWEHFRQQHFWHGWRRQHHQGRIHDFKVHULHVVWULQJRUPRXQWLQJSODQHVXEDUUD\VWULQJ
9HUL¿FDWLRQWKDW0&,VDUHLQVWDOOHGZLWKRUIHZHUPRGXOHVEHWZHHQ0&,VVKDOOEHGRFXPHQWHGIRULQVSHFWLRQE\YROWDJH
PHDVXUHPHQWORJVDQGRUDVEXLOWVWULQJOD\RXWGLDJUDPV
)RU39,QYHUWHU7KH39+&6LQLWLDWRU$&EUHDNHURUVZLWFKVKDOOEHVL]HGDQGLQVWDOOHGLQDFFRUGDQFHZLWK1(&UHTXLUHPHQWV
7KHVSHFL¿FSDUWVKDOOEHLGHQWL¿HGRQWKHDVEXLOWV\VWHPGUDZLQJV
)RU3RZHUZDOO7KH39+&6HPHUJHQF\VWRSLQLWLDWRUVKDOOKDYHWKHIROORZLQJPLQLPXPUDWLQJV2XWGRRU7\SH5RUKLJKHU9
$DQGVKDOOEHLQVWDOOHGLQDFFRUGDQFHZLWK1(&UHTXLUHPHQWV7KHVSHFL¿FSDUWVKDOOEHLGHQWL¿HGRQWKHDVEXLOWV\VWHPGUDZLQJV
Refer to the Powerwall+ installation manual for further details.
&HUWL¿FDWLRQ0DUNRI8/RQWKHLQVWDOODWLRQLQVWUXFWLRQVLVWKHRQO\PHWKRGSURYLGHGE\8/WRLGHQWLI\SURGXFWVPDQXIDFWXUHGXQGHULWV
&HUWL¿FDWLRQDQG)ROORZ8S6HUYLFH7KH&HUWL¿FDWLRQ0DUNIRUWKHVHSURGXFWVLQFOXGHVWKH8/V\PEROWKHZRUGV&(57,),('DQG
6$)(7<WKHJHRJUDSKLFLGHQWL¿HUVDQGD¿OHQXPEHU
PV HAZARD CONTROL SYSTEM | ZS PVHCS
UL 3741 REPORT DATE 10-20-21 (APPLICABLE TO ZS COMP, ZS SPAN, ZS RAMP, AND ZS SEAM)
PV RAPID SHUTDOWN ARRAY, UL 1741 CATEGORY QIJR
:$51,1*7RUHGXFHWKHULVNRILQMXU\UHDGDOOLQVWUXFWLRQV
1TESR-DS-0385-21
PV HAZARD CONTROL EQUIPMENT AND COMPONENTS
Function Manufacturer Model No.
Firmware Versions
and Checksums &HUWL¿FDWLRQ6WDQGDUG
3956(0LG&LUFXLW
Interrupter (MCI)Tesla MCI-1
15503791 N/A 8/3956(
Inverter or Powerwall+ Tesla
7.6 kW: 1538000 1
3.8 kW: 1534000 1
7.6 kW: 1850000 1
9&($)
9))%((
9&($)
UL 1741, 1998
395663956(
PV Module Tesla
657657
657N/A UL 61730
Diode Harness
1RWDSSOLFDEOHWR657Tesla 65'7+N/A UL 9703
PV Wire Jumper(s) Tesla
65%-;65%-;
65%-;65%-0LQL N/A UL 9703
Pass-Through Box Tesla 6537%N/A UL 1741
39+&6,QLWLDWRU
(PV Inverter)
'HGLFDWHG39V\VWHP$&FLUFXLWEUHDNHURU$&GLVFRQQHFWVZLWFKODEHOHGSHU1(&
UHTXLUHPHQWV
N/A
39+&6,QLWLDWRU :
(Powerwall+)
(PHUJHQF\VWRSGHYLFH1,6'/LVWHG(PHUJHQF\6WRS%XWWRQRU(PHUJHQF\6WRS
'HYLFHRU(PHUJHQF\6WRS8QLW
UL 508 or UL 60947
Parts 1, 5-1 and 5-5
1$SSOLHVWRYDULDWLRQVRIWKLVSDUWQXPEHUZLWKVXႈ[RIWZRQXPEHUVDQGRQHOHWWHU
1RWH39+&6LQVWDOODWLRQUHTXLUHPHQWVPD\UHGXFHWKHHႇHFWLYHHTXLSPHQWDQGFRPSRQHQWUDWLQJVEHORZWKHLQGLYLGXDOHTXLSPHQWDQGFRPSRQHQW
3956(UDWLQJVLQRUGHUWRDFKLHYH39+&6VKRFNKD]DUGUHGXFWLRQUHTXLUHPHQWV
PVHCS INSTALLATION REQUIREMENTS
0D[6\VWHP9ROWDJH 600 Vඌඋ
39+&60D[LPXP&LUFXLW9ROWDJH$UUD\,QWHUQDO9ROWDJH$IWHU$FWXDWLRQ165 Vඌඋ (cold weather open circuit)
0D[6HULHV&RQQHFWHG3DQHOVEHWZHHQ0&,V 10
OTHER INSTALLATION INSTRUCTIONS
1. An MCI must be connected to one end of each series string or mounting plane sub-array string.
9HUL¿FDWLRQWKDW0&,VDUHLQVWDOOHGZLWKRUIHZHUPRGXOHVEHWZHHQ0&,VVKDOOEHGRFXPHQWHGIRULQVSHFWLRQE\YROWDJH
measurement logs and/or as-built string layout diagrams.
)RU39,QYHUWHU7KH39+&6LQLWLDWRU$&EUHDNHURUVZLWFKVKDOOEHVL]HGDQGLQVWDOOHGLQDFFRUGDQFHZLWK1(&UHTXLUHPHQWV
7KHVSHFL¿FSDUWVKDOOEHLGHQWL¿HGRQWKHDVEXLOWV\VWHPGUDZLQJV
)RU3RZHUZDOO7KH39+&6HPHUJHQF\VWRSLQLWLDWRUVKDOOKDYHWKHIROORZLQJPLQLPXPUDWLQJV2XWGRRU7\SH5RUKLJKHU9
$DQGVKDOOEHLQVWDOOHGLQDFFRUGDQFHZLWK1(&UHTXLUHPHQWV7KHVSHFL¿FSDUWVKDOOEHLGHQWL¿HGRQWKHDVEXLOWV\VWHPGUDZLQJV
Refer to the Powerwall+ installation manual for further details.
&HUWL¿FDWLRQ0DUNRI8/RQWKHLQVWDOODWLRQLQVWUXFWLRQVLVWKHRQO\PHWKRGSURYLGHGE\8/WRLGHQWLI\SURGXFWVPDQXIDFWXUHGXQGHULWV
&HUWL¿FDWLRQDQG)ROORZ8S6HUYLFH7KH&HUWL¿FDWLRQ0DUNIRUWKHVHSURGXFWVLQFOXGHVWKH8/V\PEROWKHZRUGV&(57,),('DQG
6$)(7<WKHJHRJUDSKLFLGHQWL¿HUVDQGD¿OHQXPEHU
PV HAZARD CONTROL SYSTEM PVHCS | CERTIFICATION
UL 3741 REPORT DATE 8-12-21
PV RAPID SHUTDOWN ARRAY, UL 1741 CATEGORY QIJR, REPORT DATE: 2021-06-11 (REV 8-10-21)
WARNING: To reduce the risk of injury, read all instructions.