000_22-004_FB_Downtown_Finishes_stampedRenovation for:GI001 TITLE SHEETGI002 INFORMATION SHEETAD101 DEMOLITION PLAN & WALL TYPESA101 FLOOR PLAN & INTERIOR ELEVATIONSA151 REFLECTED CEILING PLAN & INTERIOR ELEVATIONSAF101 FINISHES FLOOR PLAN & SCHEDULEBUILDING CODES AND STANDARDSGENERAL NOTESINDEX TO DRAWINGSCONSTRUCTION CLASSIFICATIONOCCUPANCY CLASSIFICATION APPLICABLE CODES & STANDARDS1. MASSACHUSETTS STATE BUILDING CODE (780 CMR); 9TH EDITION.(AMENDED 2015 IBC)2. INTERNATIONAL EXISTING BUILDING CODE (IEBC); 2015 EDITION.3. INTERNATIONAL MECHANICAL CODE (IMC); 2015 EDITION.4. MASSACHUSETTS STATE PLUMBING AND FUEL GAS CODE (248 CMR).5. PORTIONS OF INTERNATIONAL FIRE CODE (IFC); 2015 EDITION.6. NFPA 101 LIFE SAFETY CODE; 2012 EDITION.7. INTERNATIONAL ENERGY CONSERVATION CODE (IECC); 2015 EDITION.8. MASSACHUSETTS ARCHITECTURAL ACCESS BOARD REGULATIONS (521 CMR).9. ADA STANDARDS FOR ACCESSIBLE DESIGN - 2010 EDITION10. MASSACHUSETTS ELECTRICAL CODE (527 CMR AND NFPA 70 - 2020 EDITION).B - BUSINESSTYPE III1. THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR ALL WORK THAT IS SHOWN ON THE CONTRACT DRAWINGS THAT IS NOT SPECIFICALLY IDENTIFIED TO BE THAT OF A SUB-CONTRACTOR, INCLUDING ALLWORK THAT IS DESCRIBED BY THE CONTRACT DOCUMENTS THAT IS NOT IDENTIFIED AS BEING ANY SPECIFIC CONTRACTOR'S RESPONSIBILITY. THE SCOPES OF WORK OF THE INDIVIDUAL FIELDSUB-CONTRACTORS ARE IDENTIFIED IN THEIR RESPECTIVE SPECIFICATION SECTIONS.2. THE GENERAL CONTRACTOR WILL PROVIDE BARRICADES, TEMPORARY LIGHTS, TEMPORARY TELEPHONE SERVICE, AND CLEAN-UP SERVICE TO THE WORK AREA.3. THE GENERAL CONTRACTOR WILL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE PRIOR TO PROCEEDING WITH THE WORK. THE GENERAL CONTRACTOR WILL COORDINATE WORK ACCORDINGLYWITH ALL SUBCONTRACTORS AND THE OWNER.4. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE COMPLETE AND THOROUGH CLEAN-UP AT THE END OF THE JOB, AND FOR DAILY REMOVAL OF CONSTRUCTION DEBRIS AND CLEAN-UP.5. THE GENERAL CONTRACTOR WILL PERFORM MINOR SPACKLING AND REPAIRS TO EXISTING WALLS THROUGHOUT THE WORK AREA, AS IS REQUIRED IN PREPARATION FOR NEW FINISHES.6. IT WILL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO VERIFY AND EXECUTE ALL WORK IN ACCORDANCE WITH THE APPLICABLE STATE BUILDING CODE, CURRENT EDITION, WITH ALL OF ITSREFERENCED PUBLICATIONS AND ALL OTHER APPLICABLE STATE, FEDERAL, AND LOCAL CODES AND REGULATIONS.7. IT WILL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO SEE THAT ALL WORK PERFORMED IS IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION'S LIFE SAFETY CODE (NFPA 101),CURRENT EDITION.8. THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS APPLICABLE TO THE SCOPE OF WORK, AS REQUIRED BY THEOWNER, AND AS REQUIRED FOR REGULATORY COMPLIANCE.9. THE GENERAL CONTRACTOR WILL PROVIDE THE OWNER WITH INSURANCE CERTIFICATES FOR THE REQUIRED INSURANCES PRIOR TO STARTING THE WORK.10. THE GENERAL CONTRACTOR WILL FILE FOR AND SECURE ALL APPROVALS, PERMITS, AND CERTIFICATES OF COMPLIANCE AS REQUIRED.11. THE GENERAL CONTRACTOR SHALL FULLY COMPLY WITH THE OWNER'S "INTERIM LIFE SAFETY POLICY" DURING THE ENTIRE CONSTRUCTION PERIOD.1st FLOOR FINISHESFLORENCE BANK58 MAIN STREETNORTHAMPTON, MA 010607/29/2022 12:47 PMTITLE SHEETGI001JRSEAL:MARK DATEISSUE-7/29/2022 PERMIT SETPROJECT NO:PROJECT ARCHITECT:PROJECT MANAGER:DRAWN BY:DATE:COPYRIGHT:22-004REKREK07/29/2022SHEET TITLE:CONSULTANT:64 GOTHIC STREET, SUITE 1NORTHAMPTON, MA 01060T 413.585.1512 F 413.586.7945www.haiarchitecture.comH AIArchitecture, Inc.1st Floor FinishesFlorence Bank58 Main StreetNorthampton, MA 01060Renovation for:PROJECT:
ZONING DISTRICT:PRINCIPAL USE:ZONING RESTRICTIONS RELATIVE TO USE:NOT APPLICABLEPARKING REQUIREMENTS:NOT APPLICABLEADDITIONAL REQUIREMENTS:NOT APPLICABLEINTERIOR ELEVATION DESIGNATIONDETAIL IDENTIFICATIONSECTION DESIGNATIONROOM AND NAME NUMBERDOOR NUMBERKEY NOTEWALL TYPEHEIGHT MARKDETAIL DESIGNATION15"-48"MIN. MAX.17"-25"36" MAX TOSPOUT OUTLET27" MIN KNEECLEARANCE48"MAX48"MAX.17" MIN34" MAXTO RIMINSULATE ALL PLUMBINGLAVATORY GUARD15"-48"MIN MAX36"36"FINISH FLOORLINE15"MIN29" MIN27" CLR40" MAX TO BOREFLECTING SURFACEHIGHESTOPERABLEPART30"-42"36"x48" CLRFLR SPACEFIRE HORN AND STROBEPer NFPA 72 the lens of thestrobe shall be no less than 80"& no greater than 96" AFF. Whenceiling heights do not allow for amin height of 80", strobes shallbe mounted within 6" of ceilingPUBLIC TELEPHONEThe highest operable part of telephone,including dial, handset and coin depositslots shall be within the reach rangesspecified in ABA Section 30830"x48" CLR FLR SPACE(FORWARD APPROACH)PUBLIC TELEPHONE(PLAN)CLOTHES HOOK/RODAccessible storagespaces shall be within atleast one of the reachranges specified in ADASection 308DUPLEX ORQUADRUPLEXRECEPTACLELAVATORYLAVATORY FORWARDAPPROACH (PLAN)DRINKING FOUNTAINWALL & POST MOUNTEDCANTILEVERED UNITSACCESSIBLEDRINKING FOUNTAINMINIMUM ACCESSIBLESHOWER CONFIGURATION(PLAN)SOAP DISPENSER NAPKIN/TAMPONVENDORPAPER TOWELDISPENSER20"MAX2'-0"MAX.80"-96" AFFFIRE ALARMPULL STATIONThe distance from anexit door to a manualpull station must notexceed 5'-0"42"-48"OPTIONAL POSTOR BASE4'-0"MAX.8" MIN30"X48" CLR FLR SPACE(FORWARD APPROACH)6" MAX.TOE CLEARANCE6" MAX TOECLEARANCEFOR FORWARDAPPROACHFOR FORWARDAPPROACHSEEPLANFORUNOBSTRUCTEDFORWARD OR SIDEREACH9" MIN TOECLEARANCE17" MINSINK5" MAXSPOUTLOCATION15" MIN8" MIN KNEECLEARANCEMIRROR1A101ABCD2A1021A101CONFERENCEROOM10052012CEILING HEIGHTEL. = 100'-0"36A101EXIT REQUIREMENTS:OCCUPANCY LOAD:1,970 SF @ 100 SF / OCCUPANT = 20 OCCUPANTS (SEE INTERNATIONAL BUILDING CODE TABLE 1004.1)MINIMUM EGRESS WIDTH CALCULATIONS (DOORS, RAMPS & CORRIDORS):MINIMUM EGRESS WIDTH CALCULATIONS (STAIRS):REQUIREMENTS FOR NUMBER OF WATER CLOSETS & LAVATORIES (USE GROUP XX):2 EXITS REQUIRED; 2 EXITS PROVIDED (SEE INTERNATIONAL BUILDING CODE TABLE 1006.3.1)CORRIDORS: 44" MIN. REQUIRED, 48" PROVIDED (SEE INTERNATIONAL BUILDING CODE 1020.2)DOORS: 36" MIN. REQUIRED, 36" PROVIDED (SEE INTERNATIONAL BUILDING CODE 1005.5)(SEE INTERNATIONAL BUILDING CODE 2902.1 & APPLICABLE STATE CODE(S)*)FEMALE TOILET 1 PER 20 OCC = 1 REQUIRED, 1 PROVIDEDFEMALE SINKS 1 PER 50 OCC = 1 REQUIRED, 1 PROVIDEDMALE TOILET 1 PER 25 OCC = 1 REQUIRED, 1 PROVIDEDMALE SINKS 1 PER 50 OCC = 1 REQUIRED, 1 PROVIDED*FOR MASSACHUSETTS WORK SEE 248 CMR; FOR CONNECTICUT WORK SEE 2018 CSBCSTAIRS: NOT APPLICABLE, NO STAIRS IN PROJECT (SEE INTERNATIONAL BUILDING CODE 1011.2)RAMPS: NOT APPLICABLE, NO RAMPS IN PROJECT AREA (SEE INTERNATIONAL BUILDING CODE 1020.2)EMERGENCYEYE WASH/ SHOWER27" MIN KNEE CLEARANCE36" MAX TO SPRAY HEAD48" MAX30"x48" CLEARFLOOR SPACEEMERGENCYEYE WASH/ SHOWER(PLAN)PAPER TOWEL DISPENSER& WASTE RECEPTACLE4'-0"MAX.FOLD DOWN SEATAS REQUIREDBABY CHANGING TABLE(FRONT)BABY CHANGING TABLE(SIDE)48"MAX34" MAX TO HIGHESTPART OF WORKSURFACE IN DOWNPOSITION27" MIN TO BTM OFWORK SURFACE30"x48" MIN CLEARFLOOR SPACE17" - 25"KNEE CLEARANCE< or = 25" DEEP44" MAX TO HIGHESTPART OF LATCH33" MIN -36" MAX7" MIN -9" MAX15" MIN -48" MAX12" MAX42" MIN6"13-1/2"MIN17" MIN -19" MAX18"TOILET TISSUEDISPENSERMount on side wall closestto water closet; shall not belocated behind grab barTOILET SIDE WALLGRAB BARSGrab bars shall be between114" & 112" in diameter & located112" clear from wallTOILET REAR WALLGRAB BARSGrab bars shall be between114" & 112" in diameter & located112" clear from wallTOILET(SIDE ELEVATION)TOILET(FRONT ELEVATION)*Flush controls shall be locatedon the open side of water closetor directly behind the toiletURINALFlush controls shall be within reachrange per ADA Section 308*Flush controls shall be located on theopen side of urinal or directly behindURINAL(PLAN)42" MIN54" MINTRANSFERSIDESIDE WALL17" MAXTO RIM44" TYPREQUIRED CLEARANCEAT TOILET5'-6" MIN6'-0" MIN18"30"x48" CLEARFLOOR SPACECLEAR FLOORSPACEPREFERREDLOCATION ISBELOW GRABBAR @ 2'-0" AFFTO CENTER OFDISPENSERREAR SWING-UPGRAB BAR(REQ'D IN CT)3'-0" MINOPEN SIDESIDE SWING-UPGRAB BAR(REQ'D IN CT)CIRCULAR SPACEThis space shall bepermitted to include knee& toe clearance complyingwith ADA Section 308T-SHAPED SPACEThis space shall be permitted toinclude knee & toe clearancecomplying with ADA Section 308 onlyat the end of the base or one arm60" DIA(MIN)36"24"12"36"12"60"60"NURSE CALL LIGHT6"EQEQNURSE CALL LIGHT;SEE ELEC. DWGS.2'-5"3'-0"ABBREVIATIONSTYPICAL FIXTURE AND MISCELLANEOUS ACCESSORY HEIGHTSCODE ANALYSISZONING ANALYSISGRAPHIC SYMBOLSON SHEET WHERE DETAIL IS TAKEN;SHEET NUMBER WHERE DRAWNDETAIL DESIGNATIONON SHEET WHERE DETAIL IS TAKEN;SHEET NUMBER WHERE DRAWNDETAIL DESIGNATIONON SHEET WHERE SECTION IS TAKEN;SHEET NUMBER WHERE DRAWNSECTION DESIGNATIONELEVATION LETTERON SHEET WHERE SECTION IS TAKEN;SHEET NUMBER WHERE DRAWNSECTION DESIGNATION74" MIN TO TOREFLECTINGSURFACE30"x48" CLEARFLOOR SPACEAB ANCHOR BOLTAAP ALARM ANNUNCIATOR PANELACST ACOUSTICALA/C AIR CONDITIONERACC ACCESSIBLEACT ACOUSTICAL CEILING TILEADDL ADDITIONALADH ADHESIVEADJ ADJACENT, ADJOINING, orADJUSTABLEAFF ABOVE FINISH FLOORAHU AIR HANDLING UNITALM ALARMALT ALTERNATEALUM ALUMINUMAHR ANCHORANOD ANODIZE(D)APPROX APPROXIMATEARCH ARCHITECTBBR BASEBOARD RADIATORBL BUILDING LINE or BUILDING LINEBD BOARDBKG BACKINGBLDG BUILDINGBLK BLOCKBLKG BLOCKINGBLW BELOWBO BOTTOM OFBOT BOTTOMBRG BEARINGBRK BRICKCO CENTER OFCAB CABINETCF/CI CONTRACTOR FURNISHED,CONTRACTOR INSTALLEDCF/OI CONTRACTOR FURNISHED,OWNER INSTALLEDCG CORNER GUARDCJ CONTROL JOINTCL CENTER LINECLG CEILINGCLKJ CAULK(ED) JOINTCLR CLEAR (DIMENSION)CMU CONCRETE MASONRY UNITCOL COLUMNCOMM COMMUNICATIONCOMP COMPACTED or COMPOSITIONCONC CONCRETECONSTR CONSTRUCTIONCONT CONTINUOUS or CONTINUECONTR CONTRACTOR or CONTRACTCONTRJ CONTROL JOINTCOORD COORDINATECTR CENTERCTRL CONTROLD DEPTHDEMO DEMOLITIONDESCR DESCRIBE or DESCRIPTIONDET DETAILDF DRINKING FOUNTAINDIA DIAMETERDIM DIMENSIONDISP DISPENSERDIST DISTANCEDMR DIMMERDN DOWNDR DOOR or DRAINDTL DETAILDUPL DUPLICATEDW DISHWASHERDWGS DRAWINGSDWR DRAWERE EASTEA EACHEIFS EXTERIOR INSULATION & FINISHSYSTEMEJ EXPANSION JOINTEL ELEVATIONELEC ELECTRIC(AL)ELEV ELEVATOREM ELECTROMAGNETICEMER EMERGENCYENGR ENGINEERENTR ENTRANCEEO ELECTRICAL OUTLETEP ELECTRICAL PANELEQ EQUALEQUIP EQUIPMENTETR EXISTING TO REMAINEWC ELECTRIC WATER COOLEREWH ELECTRIC WATER HEATEREWS EYE WASH STATIONEX EXAMPLE, EXISTINGEXH EXHAUSTEXIST EXISTINGEXP EXPANSION or EXPOSE(D)EXT EXTERIOR or EXTINGUISHERFA FIRE ALARMFAS FIRE ALARM STATIONFD FLOOR DRAINFDC FIRE DEPARTMENT CONNECTIONFDTN FOUNDATIONFE FIRE EXTINGUISHERFEC FIRE EXTINGUISHER CABINETFF EL FINISH FLOOR ELEVATIONFHC FIRE HOSE CABINETFIN FINISHFIXT FIXTUREFL FLOOR LINEFLG FLOORINGFLR FLOORFF FINISH FACEFOC FACE OF CONCRETEFOF FACE OF FINISHFOM FACE OF MASONRYFOS FACE OF STUD or SLABFOW FACE OF WALLFP FIRE PROTECTIONFRZ FREEZERFTG FOOTINGFURG FURRINGFURN FURNISH or FURNITUREFV FIELD VERIFYGA GAUGEGALV GALVANIZEDGC GENERAL CONTRACTORGEN GENERAL or GENERATORGFP GOVERNMENT FURNISHEDPROPERTYGL GLASSGLZ GLAZING (GLAZE)GRD GRADEGSF GROSS SQUARE FEETGWB GYPSUM WALL BOARDGYP GYPSUMH HIGHHAZ HAZARDHC HANDICAPPEDHDR HEADERHS HAND SINKHT HEIGHTHM HOLLOW METALHWT HOT WATER TANKHVAC HEATING, VENTILATING & AIRCONDITIONINGI INSULATE(D)ID INSIDE DIAMETER or DIMENSIONIHM INSULATED HOLLOW METALIS INSULATED STEELIN INCHINCL INCLUDEINFO INFORMATIONINSUL INSULATIONINT INTERIORJAN JANITORJST JOISTJT (OR J) JOINTK(12) KICKPLATE (HEIGHT")LAM LAMINATELAV LAVATORYLDR LEADERLL LEAD LINE(D)LT LIGHTLTG LIGHTINGMAS MASONRYMATL MATERIALMAX MAXIMUMMBR MEMBERME MECHANICAL ENGINEERMECH MECHANICALMEMB MEMBRANEMEP MECHANICAL, ELECTRICAL,PLUMBINGMFD MANUFACTUREDMFR MANUFACTURERMID MIDDLEMIN MINIMUMMOD MODIFYMT MOUNTMTD MOUNTEDMTG MOUNTING or MEETINGMTL METALMIN MINIMUMMISC MISCELLANEOUSMO MASONRY OPENINGMULL MULLIONMW MICROWAVEN NORTHNA NOT APPLICABLENE NOT EXCEEDINGNIC NOT IN CONTRACTNO NUMBERNOM NOMINALNSF NET SQUARE FEETNTS NOT TO SCALEO OXYGENOC ON CENTEROCC OCCUPANT or OCCUPYOF/CI OWNER FURNISHED, CONTRACTORINSTALLEDOF/VI OWNER FINISHED, VENDORINSTALLEDOH OVERHANGOPNG OPENINGOPP OPPOSITEPB PANIC BUTTON or PUSH BARPC PIECEPL PROPERTY LINEPBD PARTICLE BOARDPEN PENETRATE or PENETRATIONPERM PERMANENTPERP PERPENDICULARPH PHASEPLBG PLUMBINGPLAM PLASTIC LAMINATEPLAS PLASTERPR PAIRPS PULL STATIONPT PAINTPTAC PACKAGED THERMAL AIRCONDITIONERPTD PAINTEDPTN PARTITIONPVG PAVINGPLYWD PLYWOODPWR POWERRCP REFLECTED CEILING PLANRD ROOF DRAIN or ROADRECT RENTANGLEREF REFERENCE or REFRIGERATORREINF REINFORCEREM REMODELREP REPAIRREPL REPLACEREQ REQUIREREQD REQUIREDRGH ROUGHRM ROOMRND ROUNDRO ROUGH OPENINGRTU ROOF TOP UNITS SOUTHSC SOLID CORESCHED SCHEDULESCW SOLID CORE WOODSECT SECTIONSF SQUARE FOOTSIM SIMILARSK SKETCHSM SURFACE MOUNT(ED)SPEC SPECIFICATION(S)SQ SQUARESS STAINLESS STEEL or SOLID SURFACEST STAIR(S) or STREETSTD STANDARDSTL STEELSTOR STORAGESTRUCT STRUCTURALSUSP SUSPEND(ED)SW SWITCHSYS SYSTEMT TEMPEREDTO TOP OFTELE TELEPHONETEMP TEMPERATURE or TEMPORARYTHK THICKTI TEMPERED INSULATEDTLT TOILETTYP TYPICALTOC TOP OF CONCRETETOF TOP OF FOUNDATIONTOPO TOPOGRAPHYTOS EL TOP OF STEEL ELEVATIONTOS TOP OF SLAB or STEELTOW EL TOP OF WALL ELEVATIONUOD UNDERSIDE OF DECKUNO UNLESS NOTED OTHERWISEUR URINALVAC VACUUMVERT VERTICALVEST VESTIBULEVF/CI VENDOR FURNISHED,CONTRACTOR INSTALLEDVIF VERIFY IN FIELDVTR VENT THROUGH ROOFW WEST or WIDEW/ WITHW/IN WITHINW/O WITHOUTWC WATER CLOSETWD WOOD or WATER DISPENSERWDW WINDOWWH WALL HUNG or WATER HEATERYD YARD14WG (THICKNESS") WIRE GLASS14T (THICKNESS") TEMPERED GLASSFINISH FLOORLINEFINISH FLOORLINE1. CONTROLS/OPERATING MECHANISMS MUST BE PLACED WITHIN AT LEAST ONE OF THE REACH RANGES SPECIFIED IN ADA SECTION 308.2. UNLESS NOTED OTHERWISE, DIMENSIONED REACH RANGES ARE GIVEN TO HIGHEST/LOWEST OPERABLE PART.3. REQUIRED CLEAR FLOOR SPACES, CLEARANCES AT FIXTURES, & TURNING SPACES SHALL BE PERMITTED TO OVERLAP.4. DOOR SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY FIXTURE.5. DOORS SHALL BE PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE.6. ALL WORK SHALL COMPLY WITH THE CURRENT EDITION OF ADA AND ALL LOCAL CODES.7. ALL MASSACHUSETTS WORK TO COMPLY WITH CURRENT EDITION OF MA AAB.FIRE EXTINGUISHERCABINETMIRRORMirrors not located above lavatoriesshall be installed with the bottomedge of the reflecting surface max35" aff per ADA 603.3℄9" MIN TOECLEARANCE℄OPEN SIDE℄℄33" MIN -36" MAXTRANSFERSIDE3'-0"℄OPEN SIDE17" MIN -19" MAXHIGHESTOPERABLEPART30"-42"HIGHESTOPERABLEPART30"-42"HIGHESTOPERABLEPART℄℄HIGHESTOPERABLEPARTNOTES:BABY CHANGING TABLE(PLAN)7/29/2022 1:00 PMINFORMATION SHEETGI002JRSEAL:MARK DATEISSUE-7/29/2022 PERMIT SETPROJECT NO:PROJECT ARCHITECT:PROJECT MANAGER:DRAWN BY:DATE:COPYRIGHT:22-004REKREK07/29/2022SHEET TITLE:CONSULTANT:64 GOTHIC STREET, SUITE 1NORTHAMPTON, MA 01060T 413.585.1512 F 413.586.7945www.haiarchitecture.comH AIArchitecture, Inc.1st Floor FinishesFlorence Bank58 Main StreetNorthampton, MA 01060Renovation for:PROJECT:
HOLLOW METAL FRAME - PAINT; SEE FINISHSCHEDULE (TYPICAL)CAULK CONTINUOUS (BOTH SIDES)2x WOOD BLOCKING (FIRE-RETARDANT)SEE FLOOR PLAN FOR WALL TYPE12"TYP2"12"WALL ANCHORS & BASE CLIPSDOOR - SEE DOOR SCHEDULEDOOR HEAD / JAMB DETAILSCALE: 3" = 1'-0"19A101SEE WALL TYPE12"MATCH EXISTING WOOD TRIM1/4" CLEAR TEMPERED GLASSIN WOOD FRAME, CAULKCONTINUOUS BOTH SIDESWINDOW DETAILSCALE: 3" = 1'-0"20A101WOOD CASING TO MATCH EXISTINGSEE WALL TYPE FOR WALLCONSTRUCTIONWOOD GLASS STOP TO MATCH EXISTING2WALL TYPESCALE: 1" = 1'-0"FLOOR LINE5/8" TYPE "X" GYPSUM BOARD (EACH SIDE)BATT SOUND INSULATIONBASE - SEE ROOM FINISH SCHEDULECEILINGSEE RCPLINE OF STRUCTURAL DECK OR SLAB ABOVEUSE MOISTURE RESISTANT GYPSUMBOARD FOR ALL WET AREASEXISTING TO REMAIN WALL CONSTRUCTIONALIGNALIGN1WALL TYPESCALE: 1" = 1'-0"FLOOR LINE5/8" TYPE "X" GYPSUM BOARD (EACH SIDE)3-5/8" METAL STUDS AT 16" OCBATT SOUND INSULATIONBASE - SEE ROOM FINISH SCHEDULECEILINGSEE RCPLINE OF STRUCTURAL DECK OR SLAB ABOVEUSE MOISTURE RESISTANT GYPSUMBOARD FOR ALL WET AREASCAULK TO SEAL ALL GAPSCAULK TO SEALALL GAPSNON-RATED WALLNON-RATED WALLALIGNALIGN3WALL TYPESCALE: 1" = 1'-0"FLOOR LINENEW 58" TYPE "X" GYPSUM BOARD ONFURRING AT 16" OCNEW THERMAL INSULATIONBASE - SEE ROOM FINISH SCHEDULECEILINGSEE RCPUSE MOISTURE RESISTANT GYPSUMBOARD FOR ALL WET AREASEXISTING TO REMAIN WALL CONSTRUCTION &STOREFRONT SYSTEM WITH GLASS PANELS ATTOP & ALUMINUM PANELS AT BOTTOMNON-RATED WALLALIGNNEW SOLID SURFACE SILL WITH 18"REASED EDGES & 1" RETURNSFV112"1"DNEPREMOVE12 DOOR& PATCHFRAMEPFPFF.E.PPVAULT/ATM ROOM04TELLERLINE0502ENTRANCEVESTIBULE01WORKROOM13UTILITYROOM12TOILETROOM11WAITING06LOBBY03CSROFFICE07ASST. MANAGEROFFICE08BRANCH MANAGEROFFICE09CONFERENCEROOM10TELLEROPERATIONS14REMOVE SOLID SURFACE SILL,PREPARE LOW WALL TO BEEXTENDED TO CENTER OFMULLION AT TOP OF ALUMINUMPANEL - TYPICAL OF (3) OFFICESREMOVE CHECK DESK ASSEMBLYIN ENTIRETY, REPAIR WALL ASREQUIRED TO RECEIVE PAINT PERSCHEDULE16WIREMOLD16WIREMOLD5a675a6756756756756756756756756744444444444444REMOVE ALL WOOD CHAIR RAIL INROOM4REMOVE WIRE MOLD IN ENTIRETY9232398ATM ROOM FLOORING TO REMAIN1313444REMOVE/MODIFY DOOR FRAME INPREPARATION FOR NEW WINDOWAS SCHEDULEDREMOVE (8) (VIF) 6" RECESSEDCAN LIGHT FIXTURES FORREPLACEMENT WITH NEW FLAT 6"ROUND RECESSED LED FIXTURESIN THE SAME LOCATIONSREMOVE IN ENTIRETY (5) 4"RECESSED CAN LIGHT FIXTURESIN ARCHED CONFIGURATION,PATCH CEILING; MODIFY CIRCUITAS REQUIRED FOR NEW LIGHTFIXTURES AS SCHEDULEDREMOVE LIGHT FIXTURE ANDCANOPY AND PREP FOR NEWLIGHT FIXTURE AS SCHEDULEDREMOVE (2) FLUSH MOUNTCEILING FIXTURES, PREPARECEILING FOR NEW FIXTURES INSAME LOCATIONSREMOVE CHAIR RAIL IN ENTIRETYIF THE EXISTING TILE DOES NOTEXTEND BELOW THE CURVEDTELLER LINE SCHEDULED FORREPLACEMENT WITH A NEWSTRAIGHT RUN OF MILLWORK,INFILL AS REQUIRED TO INSTALLTHE NEW FLOORING ASSCHEDULEDADDRESS EXISTING TO REMAINDOORS (CLEARANCE TO FLOOR)AND THRESHOLDS AS REQUIREDTO ACCOMMODATE NEWFLOORINGTHE INTENT IS TO RETAIN ASMUCH OF THE EXISTING CEILINGAS POSSIBLE IN THE AREA WHEREWALLS ARE MODIFIED & TO PATCHIN TO MATCH AT THE NEW WALLSREMOVE & DISPOSE OF UNDERCOUNTER SAFE, COORDINATEWITH OWNERNOT USEDREMOVE EXISTING PLUMBING FIXTURES (SINK, WATER CLOSETS, SHOWERS, ETC) AND ALLACCESSORIES. REMOVE ALL PLUMBING LINES (HOT AND COLD WATER, WASTE AND VENT) TONEAREST CONCEALED AREA (WALL, FLOOR, CEILING OR CHASE). PROVIDE VALVE AND CAP ATAPPROPRIATE SOURCE. COORDINATE WITH OWNER'S REPRESENTATIVE FOR ACCEPTABLECAP AND VALVE LOCATIONS. PATCH DISTURBED AREAS TO MATCH EXISTING AND NEW WORK.EXISTING PLUMBING FIXTURES TO BE REMOVED SHALL BE REMOVED TO THE OWNER'SSTORAGE.REMOVE EXISTING GYPSUM OR PLASTER CEILING. PREPARE TOPS OF WALLS AT REMOVEDCEILING FOR SMOOTH TRANSITION TO NEW EXTENSION OF WALLS TO STRUCTURE ABOVE.REMOVE ANY ELECTRICAL DEVICES, (OUTLETS, SWITCHES, LIGHT FIXTURES, CLOCKS, ETC)WHERE REQUIRED TO ACCOMMODATE NEW CONSTRUCTION. ALSO REMOVE ALL RELATEDWIRING AND CONDUIT, EXCEPT WHERE THE CONDUIT IS SCHEDULED TO REMAIN FOR REUSE.REMOVE THE CONDUIT AND WIRING BACK TO THE NEAREST CONCEALED AREA (WALL, FLOOR,CEILING OR CHASE) AND DISCONNECT THAT CIRCUIT FROM THE BUILDING'S POWER SYSTEM.SEE ELECTRICAL PLANS FOR EXACT LOCATIONS OF ELECTRICAL DEVICES TO BE REMOVED.PATCH AND REPAIR SURFACES AS REQUIRED TO MATCH EXISTING AND NEW WORK. EXISTINGELECTRICAL DEVICES AT EXISTING WALLS TO REMAIN (TYPICAL)REMOVE WALL COVERING, WHERE PRESENT, INCLUDING CERAMIC TILE AND/OR SPECIALTYPANELS. CLEAN AND PREPARE EXISTING SUBSTRATE AND PATCH HOLES AS REQUIRED TOFACILITATE INSTALLATION OF NEW FINISH AS SPECIFIED IN THE FINISH SCHEDULE.REMOVE EXISTING DOORS AND DOOR FRAMES AS SCHEDULED. PATCH AND REPAIR WALLS,FLOORS AND CEILINGS TO MATCH EXISTING AND NEW WORK AS SCHEDULED. RELOCATE ANDREFINISH/RECONDITION DOORS THAT ARE SCHEDULED TO BE RELOCATED IN THE DOORSCHEDULE.REMOVE EXISTING SUSPENDED ACOUSTICAL CEILING SYSTEM, INCLUDING ALL TILES, GRIDS,HANGERS, AND TRACKS. PATCH & REPAIR WALLS AS REQUIRED TO MATCH NEW & EXISTINGWORK TO REMAIN - REFER TO MEP DRAWINGS FOR ADDITIONAL ASSOCIATED ITEMS.REMOVE EXISTING BASE (VINYL, TILE, ETC). CLEAN AND PREPARE THE EXISTING SUBSTRATEAS REQUIRED TO FACILITATE THE INSTALLATION OF NEW BASE. SEE ROOM FINISH SCHEDULEFOR NEW BASE TYPE.REMOVE EXISTING FLOOR COVERING (VINYL, TILE, ETC); PATCH AND REPAIR FLOOR ASREQUIRED. CLEAN AND PREPARE THE EXISTING SUBSTRATE AS REQUIRED TO FACILITATE THEINSTALLATION OF NEW FLOOR COVERING. (SEE ROOM FINISH SCHEDULE FOR NEW FLOORCOVERING). NOTE: ALL FLOORS IN ROOMS OR AREAS THAT ARE SCHEDULED TO RECEIVE NEWFLOOR COVERING WILL HAVE THE EXISTING FLOOR COVERING REMOVED IN THAT AREA,UNLESS NOTED OTHERWISE. GENERAL CONTRACTOR TO ENSURE THAT THE FLOOR IS LEVELPRIOR TO INSTALLING NEW FLOORING.REMOVE EXISTING CABINET WORK, COUNTERS, SHELVING, EQUIPMENT AND OTHER BUILT-INITEMS AS SHOWN OR OTHERWISE CALLED OUT TO BE REMOVED. PATCH SURFACES ASREQUIRED TO RECEIVE NEW FINISH SURFACES.WHERE EXISTING PARTITIONS, OR PORTIONS OF SAME, ARE REMOVED, TO ACCOMMODATENEW DOORS OR WINDOWS, COUNTERS, OR CABINETS BECAUSE OF DEMOLITION, PATCH ANDREPAIR WALLS, FLOORS, AND CEILINGS TO MATCH EXISTING AND NEW WORK AS SCHEDULED.WHERE EXISTING CMU WALLS ARE REMOVED TO ACCOMMODATE NEW DOORS OR WINDOWS,PROVIDE NEW LINTELS OVER THE OPENING AS REQUIRED. SEE LINTEL SCHEDULE. LEAVEJAMBS CLEAN AND SQUARE FOR APPLICATION OF NEW DOOR OR WINDOW FRAME.PROVIDE TEMPORARY DUSTPROOFING PARTITIONS AT ALL EXISTING AREAS THAT ABUT THEWORK AREA AND WHERE INDICATED ON THE DRAWINGS. TEMPORARY PARTITIONING SHALL BELOCKABLE, AND SHALL EXTEND FROM FLOOR TO UNDERSIDE OF STRUCTURE ABOVE. SEEDRAWINGS FOR LOCATIONS. CONTRACTOR TO USE RIGID TEMPORARY PARTITION (MODULARSYSTEM) AS APPROVED BY OWNER.THE FOLLOWING DEMOLITION NOTES REFER ONLY TO THE GENERAL SCOPE OF DEMOLITIONREQUIRED TO COMPLETE THIS PROJECT, AND MAY NOT SPECIFICALLY IDENTIFY EACH AND EVERYCOMPONENT OF AN ARCHITECTURAL, MECHANICAL, ELECTRICAL, OR PLUMBING SYSTEM ORASSEMBLY (WHETHER DESIGNATED ON THE DEMOLITION PLAN(S) OR NOT). THE GENERALCONTRACTOR AND HIS/HER SUBCONTRACTORS SHALL BE REQUIRED TO REMOVE/DEMOLISHINCIDENTAL ITEMS THAT MAY BE CONSTRUED TO BE RELEVANT TO THE SCOPE OF DEMOLITIONSHOWN ON THE DEMOLITION PLAN(S), OR REQUIRED TO COMPLETE THE NEW WORK. THE GENERALCONTRACTOR SHALL BE REQUIRED TO DEMOLISH SPECIFIC ITEMS, WHETHER OR NOT THEY ARESPECIFICALLY INDICATED.THE GENERAL CONTRACTOR SHALL BE REQUIRED TO CUT ALL HOLES IN FLOORS, WALLS, CEILINGS,ETC AS REQUIRED FOR MECHANICAL OR ELECTRICAL WORK IDENTIFIED IN THE CONTRACTDOCUMENTS (INCLUDING, BUT NOT LIMITED TO DUCTWORK, HYDRONIC PIPING, FIRE SUPPRESSIONPIPING, PLUMBING PIPING, AND/OR ELECTRICAL CONDUIT FOR POWER / DATA / LOW VOLTAGE /SPECIALTY SYSTEMS). GENERALLY, THESE PENETRATIONS ARE NOT SHOWN ON THE CONTRACTDRAWINGS; HOWEVER, THE GENERAL CONTRACTOR (OR APPROPRIATE SUBCONTRACTOR) SHALL BERESPONSIBLE FOR CORING OPERATIONS, AND SLEEVING PENETRATIONS WHERE REQUIRED, WITH AMATERIAL THAT IS SUITED TO THE TYPE OF PENETRATION AND RATING OF THE ASSEMBLY BEINGPENETRATED. THE GENERAL CONTRACTOR SHALL BE REQUIRED TO PATCH AND REPAIR ALLDAMAGED SURFACES TO MATCH EXISTING AND/OR AS REQUIRED BY THE NEW WORK.1REMOVE EXISTING INTERIOR WINDOW ASSEMBLIES INCLUDING INTERIOR TRIM ASSCHEDULED. PATCH AND REPAIR WALLS, FLOORS, AND CEILING TO MATCH EXISTING AND NEWWORK AS SCHEDULED.IN ALL AREAS WHERE DEMOLITION OCCURS REFER TO M/E/P DRAWINGS FOR SPECIFICSIF HAZARDOUS MATERIALS ARE ENCOUNTERED DURING DEMOLITION OPERATIONS, IMMEDIATELYNOTIFY OWNER AND COMPLY WITH ALL APPLICABLE REGULATIONS, LAWS, AND ORDINANCESCONCERNING REMOVAL, HANDLING AND PROTECTION AGAINST EXPOSURE OR ENVIRONMENTALPOLLUTION.REMOVE EXISTING STUD PARTITIONS, CMU OR BRICK OR PORTIONS OF SAME (INCLUDING ALLELECTRICAL DEVICES AND WIRING, PLUMBING FIXTURES AND PIPING AND ANY OTHER ITEMSMADE OBSOLETE BY THE REMOVAL OF THE PARTITION), CHASES, DOORS, FRAMES ANDMISCELLANEOUS CONSTRUCTION ITEMS. PATCH AND REPAIR WALLS, FLOORS, CEILINGS TOMATCH EXISTING AND NEW WORK AS SCHEDULED.REMOVE PORTION OF EXISTING HANDRAILS. MODIFY ENDS TO RETURN TO WALL - MATCHEXISTING.REMOVE EXISTING FIRE PROTECTION PIPING AND HEADS AS REQUIRED TO SUIT NEW WORK.EXTEND AND/OR RECONFIGURE PIPING AS REQUIRED - SEE FIRE PROTECTION DRAWINGS FORFURTHER INFORMATION. COORDINATE ANY REQUIRED SHUT DOWNS WITH THE OWNER.23456789101112131415161718121417161315REMOVE CEILING ACCESSORIES.19REMOVE EXISTING HVAC DUCTWORK VALVES, CONTROLS, WIRING, THERMOSTATS, DUCTHANGERS, RADIATORS, RADIATOR ENCLOSURE COVERS AND ALL EQUIPMENT ACCESSORIES,ANY MISCELLANEOUS HVAC ACCESSORIES THAT REQUIRE REMOVAL WITH THE DEMOLITIONOF WALLS AND/OR CEILINGS. REMOVE THE DUCTWORK AND PIPING BACK TO THE NEARESTAPPROPRIATE CONCEALED AREA AND CAP THE DUCTS AND LINES IN QUESTION. PATCH ANDREPAIR SURFACES AS REQUIRED TO MATCH EXISTING AND NEW WORK AND MAINTAINREQUIRED FIRE RATINGS. SEE HVAC DRAWINGS FOR FURTHER INFORMATION. COORDINATEWITH OWNER'S REPRESENTATIVE FOR INFECTION CONTROL POLICIES.REMOVE EXISTING TEL/DATA LINES, RECEPTACLES, AND/OR DEVICES WHERE REQUIRED TOACCOMMODATE NEW CONSTRUCTION. ALSO REMOVE ALL RELATED WIRING AND CONDUIT,EXCEPT WHERE THE CONDUIT IS SCHEDULED TO REMAIN FOR REUSE. REMOVE THE CONDUITAND WIRING BACK TO THE NEAREST CONCEALED AREA (WALL, FLOOR, CEILING OR CHASE)SEE ELECTRICAL PLANS FOR EXACT LOCATIONS OF TELE/DATA DEVICES TO BE REMOVED.PATCH AND REPAIR SURFACES AS REQUIRED TO MATCH EXISTING AND NEW WORK.DEMOLITION KEYNOTESTEMPORARY DUSTPROOFING PARTITIONEXISTING CONSTRUCTIONDEMOLITIONLEGENDTPTPTPXKEYED DEMOLITION NOTES1. GENERAL CONTRACTOR MUST VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE ANDREPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING WITH THE WORK.2. ANY REPAIRS, PATCHING, OR DEMOLITION INDICATED ON DRAWINGS REPRESENT THE GENERALAREA WHERE WORK IS TO BE DONE, BUT DOES NOT NECESSARILY LIMIT THE EXTENT OF WORK.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL SUCH REPAIRS, PATCHING, ETC. WHERETHEY OCCUR IN BUILDING UNDER THIS CONTRACT.3. PROVIDE TEMPORARY DUST PROOFING PARTITIONS TO EFFECTIVELY SEAL OFF WORK AREASFROM THE REST OF THE BUILDING. PROVIDE TEMPORARY DOOR IF NECESSARY. TEMPORARYPARTITIONS SUBJECT TO APPROVAL OF OWNER AND ARCHITECT.4. REPAIR ANY IRREGULARITIES IN SURFACES INCLUDING BUT NOT LIMITED TO AREAS DISTURBEDBY NEW WORK. EXISTING SURFACES INCORPORATED INTO NEW WORK SHALL BE REPAIRED ANDRE-FINISHED TO THE SAME STANDARD AS NEW WORK.5. CONSTRUCT NEW INTERIOR PARTITIONS FROM FLOOR TO THE BOTTOM OF THE STRUCTURE(DECK OR SLAB) ABOVE UNLESS NOTED OTHERWISE VERIFY IN FIELD.6. ALL WORK TO BE CONSIDERED AS NEW WORK UNLESS INDICATED AS EXISTING TO REMAIN.7. WHERE UTILITY AND MECHANICAL WORK IS REMOVED OR ALTERED, GENERAL CONTRACTOR ISRESPONSIBLE FOR PREPARING AND PATCHING BUILDING STRUCTURE TO MATCH NEW ANDEXISTING WORK AS INDICATED ON DRAWINGS.8. GENERAL CONTRACTOR TO PROVIDE BLOCKING AS REQUIRED FOR ALL WALLS, NEW OREXISTING, THAT ARE TO RECEIVE NEW OR EXISTING CABINETRY, SHELVING, ETC.9. ALL DOORS AND WALLS NOT LABELED WITH A WALL TYPE OR DOOR NUMBER ARE TO BECONSIDERED EXISTING TO REMAIN.10. FURNITURE SHOWN ON DRAWINGS, EXCEPT CASEWORK, IS NOT INCLUDED IN THIS CONTRACTUNLESS NOTED OTHERWISE.11. DIMENSIONS ARE TAKEN FROM FACE OF FINISHED CONSTRUCTION. CLEAR DIMENSIONS ARE TOFINISHED FACE OF CONSTRUCTION AND SHALL TAKE PRECEDENCE OVER ANY OTHERDIMENSION.GENERAL CONSTRUCTION NOTESROOM NAME AND ROOM NUMBERDOOR NUMBERNEW WALL CONSTRUCTIONEXISTING CONSTRUCTIONWALL TYPENEW HALF WALL CONSTRUCTION (U.N.O.)ROOMNAMEXXXXXX1NEW MILLWORK / CASEWORK WITH PLASTIC LAMINATE COUNTERTOPNEW MILLWORK / CASEWORK WITH SOLID SURFACE COUNTERTOPSECURITY CAMERAFIRE ALARM PULL STATIONFIRE ALARM HORN/STROBECEILING - MOUNTED EXIT SIGNWALL - MOUNTED EXIT SIGNEMERGENCY LIGHTPFFFIRE ALARM STROBELEGENDPBPUSH BUTTON & DOOR OPENER (ABOVE)AREA OF NO RENOVATION♦♦♦♦♦1 HOUR FIRE RATING♦♦♦♦♦♦2 HOUR FIRE RATINGDEMOLITION WORKPREPARE EXISTING AREA OF TILE FLOORING TO RECEIVE NEW FLOORING AS SCHEDULED.ADJUST THRESHOLDS AND EXISTING TO REMAIN DOORS AS REQUIRED. IF REQUIRED, INFILLTHE AREA OF FLOORING WHERE CURVED THE TELLER LINE MILLWORK IS SCHEDULED TO BEREPLACED WITH A STRAIGHT RUN.5a7/29/2022 10:56 AMDEMOLITION PLAN& DETAILSAD101JRSEAL:MARK DATEISSUE-7/29/2022 PERMIT SETPROJECT NO:PROJECT ARCHITECT:PROJECT MANAGER:DRAWN BY:DATE:COPYRIGHT:22-004REKREK07/29/2022SHEET TITLE:CONSULTANT:64 GOTHIC STREET, SUITE 1NORTHAMPTON, MA 01060T 413.585.1512 F 413.586.7945www.haiarchitecture.comH AIArchitecture, Inc.1st Floor FinishesFlorence Bank58 Main StreetNorthampton, MA 01060Renovation for:PROJECT:PLANNORTHFIRST FLOOR DEMOLITION PLANSCALE: 1/4" = 1'-0"
TELLER LINE - GUEST SIDEINTERIOR ELEVATIONSCALE: 1/2" = 1'-0"8A101A4" ABOVE MAIN CEILING4'-11"2'-10"3'-8"12A20119A20117A50116A50114A501ACCENT LAMINATE PERFINISH SCHEDULE(TELLER LINE)12" CURVED FRONTDIVIDER PANEL(TYPICAL) - SEEFINISH SCHEDULETYPTYPICAL OF (4)TYPIF REQUIRED FOR PAINTING,TEMPORARILY REMOVE, STORE SAFELYAND RE-INSTALL EXISTING WALLGRAPHICS IN EXISTING LOCATIONTYP(5) NEW LIGHT FIXTURES PER LIGHTINGFIXTURE SCHEDULE, MOUNT ON TELLERSIDE - SEE RCPPAINT EXISTING TO REMAIN SOFFIT"SPARKLING SUN" YELLOW(5) SOLID SURFACE BOXES ATCUSTOMER SIDE OF TELLER LINE- SEE FINISH SCHEDULE; AT ENDSTATION THE CUSTOMER SIDE BOXCONTINUES ACROSS THE TELLERLINE TO BECOME THE STAFF WORKCOUNTERPLASTIC LAMINATE ON ALL EXPOSEDSURFACES OF TELLER LINE NOTCALLED OUT AS SOLID SURFACE(TYPICAL) - SEE FINISH SCHEDULE6"BASE PER FINISHSCHEDULE (WALLS)DNEPPFPFCOPIERMWF.E.PPTELLER LINE - STAFF SIDEINTERIOR ELEVATIONSCALE: 1/4" = 1'-0"13A101ABTCRTCRCHECK DESKVAULT/ATM ROOM04TELLERLINE05ATM02ENTRANCEVESTIBULE01NEWCLOSET14aWORKROOM13UTILITYROOM12TOILETROOM11WAITING06LOBBY03CSROFFICE07ASST. MANAGEROFFICE08BRANCH MANAGEROFFICE0912'-6"4'-9" STANDINGHEIGHT COUNTER2'-1"5'-7"17'-0"9'-10"28'-1"26'-2"14'-7"8'-6"6'-1"7'-8"6'-1"9'-10" VIF10'-212"11'-10"13'-0"14'-4"11'-1"13'-9"5'-0" CLEAR3'-914"1'-6"4'-10"+/-5'-0" CLEAR4"RELOCATE LIGHT SWITCH ASREQUIRED TO ACCOMMODATENEW WALLNEW WHITE MELAMINESHELVES - SEE 3/A501NEW BASE BID: SOLIDSURFACE, ALTERNATE #1:PLASTIC LAMINATE COUNTER;COORDINATE COUNTERTOPSUPPORT BRACKETS WITHMETAL FILE PEDESTALS BYFURNITURE VENDORACCESSIBLE HEIGHT TELLERWINDOW - SEE INTERIORELEVATIONEXCEPT WHERE NOTEDOTHERWISE, NEW STANDINGHEIGHT SOLID SURFACECOUNTER ON STAFF SIDE OFTELLER LINE, COORDINATECOUNTERTOP SUPPORTBRACKETS WITH METAL FILEPEDESTALS BY FURNITUREVENDOR - SEE INTERIORELEVATIONSBUILD UP LOW WALL WITHNEW SOLID SURFACE WINDOWSILL ABOVE EXISTING TOREMAIN BASEBOARD HEATERTO CENTER OF MULLION ATTOP OF ALUMINUM PANEL,THE INTENT IS TO IMPROVETHERMAL INSULATION AT THESTOREFRONT SYSTEM -TYPICAL OF THREE OFFICESREMOVE WIRE MOLD ANDLOCATE OUTLETS ASREQUIRED IN WALL, VERIFYWITH OWNER IF ADDITIONALOUTLETS ARE REQUIRED -TYPICAL AT TELLER LINE &TELLER OPERATIONSBREAKROOM10EXISTING FLOORING ANDPAINT ARE TO REMAIN IN ATMROOM, PROTECT DURINGWORKEXISTING FLOORING ANDPAINT ARE TO REMAIN INUTILITY ROOM, PROTECTDURING WORKTELLEROPERATIONS144'-9"3'-0"1'-0"OH1'-10"ABINTERIOR ELEVATIONSCALE: 1/4" = 1'-0"20A101MIRROR WITH TOP AND BOTTOMSURFACES AT ADA HEIGHTS PER GI002NEW SOLID SURFACE COUNTER WITHINTEGRAL SINK (WHITE, OVAL SHAPE) & PLAMSKIRTS, ADA COMPLIANT - SEE 6/A501OWNER STANDARD PAPER TOWELDISPENSER AT 42" AFF, OF/CIEXISTING TO REMAIN GRAB BARSNEW OWNER STANDARD TOILET, WHITESTORAGE CABINET - SEE DETAIL 1/A501;CENTER ON TOILET5'-0"TOILET ROOM #010BASE PERFINISHSCHEDULE2'-6"8A101A13A101BA18A101B12111NEW 3'-0" WIDE DOOR INHOLLOW METAL FRAME WITHHEIGHT TO MATCH EXISTINGNEW 3'-0" WIDE FLUSH DOOR INHOLLOW METAL FRAME WITHHEIGHT TO MATCH EXISTING,PAINT DOOR & FRAME PERFINISH SCHEDULE007014aNEW 4'-0" WIDE DOUBLE DOORIN HOLLOW METAL FRAME W/HEIGHT TO MATCH EXISTING010NEW 3'-6" WIDE WINDOW INWOOD FRAME WITH HEIGHT &FRAME TO MATCH EXISTINGA4A151A B9A151A18"18"18"18"18"18"18"10A151A4'-9"+/-3'-5"+/-1'-2"2'-1"5'-0"9'-7"+/-2'-1"10'-6"3'-1"7"1'-012"9"7"1'-9"18A101A1'-0"18A101CCHECK DESKINTERIOR ELEVATIONSCALE: 1/4" = 1'-0"18A101ACB4'-9"1" OVERHANG3'-4"4"3'-0"1'-2"3'-10"1" OVERHANG1" OVERHANG1" OVERHANG1'-0" OVERHANG2'-0"4"6"1" OVERHANG3'-4"2'-4"3'-10"1"1"1'-11"11"8'-0"+/-8'-0"+/-2'-634"2'-1"GFCI 48"COFFEE1'-6"CLEARBREFGFCI 72"BASE PERFINISHSCHEDULEOPENSPACE4'-11"TOP SURFACE3'-4"COUNTERS3'-8"DIVIDERS2'-6"COORDINATE COUNTERTOPSUPPORT BRACKET LOCATIONSWITH METAL FILE PEDESTALS(TYPICAL) - SEE MILLWORKNOTESOPENSPACESPEED BRACEBRACKETS (TYPICAL) -SEE MILLWORK NOTES19A50117A50116A5019A501OPENSPACEOPENSPACEOPENSPACEOPENSPACEBASE PER FINISHSCHEDULEBASE PER FINISHSCHEDULE (TYPICAL)TYPTYPTYPOPEN TO LOBBYSOLID SURFACE COUNTER(TYPICAL) - SEE FINISHSCHEDULEPLASTIC LAMINATE ON ALL EXPOSED SURFACES OFTELLER LINE CUBBIES AND HIGH TRANSACTIONSECTIONS (TYPICAL) - SEE FINISH SCHEDULEIF REQUIRED FORPATCHING/REPAIR ORPAINTING, TEMPORARILYREMOVE, STORE SAFELYAND RE-INSTALL EXISTINGWALL GRAPHICS INEXISTING LOCATIONBASE BID: SOLID SURFACECOUNTER, ALTERNATE #1:PLASTIC LAMINATECOUNTER; PROVIDECOORDINATING COLORGROMMETS, LOCATE INFIELD - SEE FINISHSCHEDULE2'-10" ADACOUNTERREMOVE WIREMOLD INENTIRETY AND REPLACEWITH OUTLETS IN WALLAS REQUIREDNEW CHECK DESK WITH SOLIDSURFACE TOPS WITH CLEAR ACRYLICDEPOSIT SLIP SLOTS AND PLASTICLAMINATE BASE CABINET WITH DOORSTO TELLER LINE SIDE4A501PAIR OF DOORS ON NEWCHECK DESK ON WAITINGAREA SIDE OF WITH NOPULLS, OPERATE VIA LOCK& CONCEALED CATCHBLANK PANEL ATEND OF NEW DESKOVERLAPPINGCOLUMNEXISTINGATTACHEDCOLUMNEXISTINGATTACHEDCOLUMNNEW CHECKDESK WITHSOLID SURFACETOPS, CLEARACRYLIC SLIPCUBBIES, &PLASTICLAMINATEFACES & BASE2'-6"2'-1"2'-0"2'-0"2'-10"333NEW WHITE MELAMINESHELVES ON EX STANDARDSCASHADVANCECURRENCYCOUNTERPRINTERVERIFY POWER & DATAREQUIREMENTS OFCOUNTERTOP EQUIPMENTWITH OWNER (TYPICAL)WALLPHONEPASSBOOKPRINTERTYPEWRITERWALLPHONEPRINTERFILE CAB.(BELOW)FILE CAB.(BELOW)FILE CAB.(BELOW)WALLPHONEWALLPHONE3'-6"4'-6" (TO TOP)OPENSPACE1"12"6'-0"6'-0"NEW PENDANTLIGHT FIXTURE- SEE RCPNEW PENDANTLIGHT FIXTURE- SEE RCP1'-6"1'-6"7/29/2022 11:50 AM1st FLOOR PLAN &INTERIOR ELEVATIONSA101JRSEAL:MARK DATEISSUE-7/29/2022 PERMIT SETPROJECT NO:PROJECT ARCHITECT:PROJECT MANAGER:DRAWN BY:DATE:COPYRIGHT:22-004REKREK07/29/2022SHEET TITLE:CONSULTANT:64 GOTHIC STREET, SUITE 1NORTHAMPTON, MA 01060T 413.585.1512 F 413.586.7945www.haiarchitecture.comH AIArchitecture, Inc.1st Floor FinishesFlorence Bank58 Main StreetNorthampton, MA 01060Renovation for:PROJECT:PLANNORTHFIRST FLOOR PLANSCALE: 1/4" = 1'-0"
DNEPPFPFF.E.PPVAULT/ATM ROOM04TELLERLINE0502ENTRANCEVESTIBULE01NEWCLOSET14aWORKROOM13UTILITYROOM12TOILETROOM11WAITING06LOBBY03CSROFFICE07ASST. MANAGEROFFICE08BRANCH MANAGEROFFICE09BREAKROOM10TELLEROPERATIONS14REPLACE (8) (VIF) 6" RECESSEDCAN LIGHT FIXTURES WITH NEWFLAT 6" ROUND RECESSED LEDFIXTURES IN THE SAMELOCATIONSPATCH CEILING AS REQUIRED ATLOCATION OF (5) DEMOLISHED 4"RECESSED CAN LIGHT FIXTURESIN ARCHED CONFIGURATIONREPLACE ROUND LIGHT FIXTUREIN EXISTING LOCATION WITH NEWLINEAR FIXTURE AS SCHEDULEDINSTALL (2) NEW FLUSH MOUNTCEILING FIXTURES IN EXISTINGFIXTURE LOCATIONS1MODIFY CEILING AS REQUIREDFOR NEW CLOSET4"PAINT BOTH SIDES OF THEEXISTING TO REMAIN SOFFIT"SUNSHINE" YELLOW, BOTTOMCEILING WHITEINSTALL (5) NEW PENDANT LIGHTFIXTURES PER SCHEDULE,CENTER SIDE TO SIDE AT EACHTELLER OPENING AND LOCATEFIXTURE 6" BEHIND ETR SOFFITRELAMP ALL EXISTING TO REMAIN2x4 AND 2x2 LIGHT FIXTURES WITHLED LAMPS (TYPICAL OF PROJECT)NEW FLAT 6" ROUND LED LIGHTFIXTURE WITH ACOUSTIC CEILINGTRIM KIT2222222REPLACE RECESSED CAN LIGHTFIXTURE WITH NEW 2X2 LIGHTFIXTUREMODIFY EXISTING TO REMAINCEILING GRID AS REQUIRED TOACCOMMODATE NEW WALLSREPLACE EXISTING RECESSEDCAN LIGHT WITH NEW FLAT 6"ROUND LED LIGHT FIXTURE WITHACOUSTIC CEILING TRIM KITTELLER OPERATIONSINTERIOR ELEVATIONSCALE: 1/4" = 1'-0"4A101AB3'-6"COUNTERSSHREDDERNEW PLASTIC LAMINATECOUNTER WITHMINIMAL AVERHANGSAT STAIR ENCLOSURE -SEE 13a/A501OPENSPACEBASE PER FINISHSCHEDULE (TYPICAL)PLAM COUNTERS,COORDINATE SUPPORTBRACKETS WITH FILEPEDESTALS - SEE FINISHSCHEDULE2'-6"COUNTER5'-1"9'-7"9A5011A5012'-6"2'-6"2'-6"UPPER CABINETSWITH PLAM ONALL EXPOSEDSURFACES - SEEFINISH SCHEDULENEW CLOSET WITH4'-0"x7'-0" DOUBLEFLUSH DOORS INHOLLOW METAL FRAME,PAINT DOORS & FRAMEPER FINISH SCHEDULE;ALIGN SHORT WALL OFCLOSET WITH STAIRENCLOSURE WALL(SEE PLAN)EXISTING CORNER(BEHIND)ASTAFF BREAK ROOMINTERIOR ELEVATIONSCALE: 1/4" = 1'-0" 9A101FRIDGE(NIC)BASE PERFINISHSCHEDULENEW MILLWORKWITH PLASTICLAMINATE ON ALLEXPOSEDSURFACES;LRAD171655ELKAYLUSTERTONE17"x16"x6-1/2",ADA SINK W/FAUCET WITH4" BLADEHANDLESNEW 3'-0"FLUSH DOORIN HOLLOWMETAL FRAME,PAINT DOORAND FRAMEWORK ROOMINTERIOR ELEVATIONSCALE: 1/4" = 1'-0" 10A101ABASE PERFINISHSCHEDULENEW MILLWORKWITH SOLIDSURFACE COUNTERAND PLAM ON ALLEXPOSEDSURFACES;LRAD171665ELKAYLUSTERTONE17"x16"x6-1/2",ADA SINK W/FAUCET WITH4" BLADEHANDLESCOPIER2'-0"1" FILLER2'-0"1" FILLERBMICRO.(NIC)2" FILLER1'-10"2'-0"A5018A5017A50111'-3"2'-6"2'-0"1'-4"2'-0"1'-4"2'-0"2'-2"A50112'-3"2'-0"5'-0"2'-10"1" FILLERA50122'-6"1'-0"1" FILLER2'-8"A50181" FILLER1" FILLER℄AAAABBBBBB BFFDEEMPTYCORNER, TOP& BOTTOMREPAD EXISTING CEILINGS INEXISTING TO REMAIN GRID, ADDSHORT CEILING GRID MEMBERSAS REQUIRED WHERE 2x4 LIGHTFIXTURES ARE REPLACED WITH2x2 FIXTURES, TYPICALOPENSPACEEQEQ1'-6"LOCATION OF NEW PENDANTSHOWN IS IN REFERENCE TO THENEW CHECK DESK MILLWORKBELOW, BOTTOM OF GLASS TO BE6'-0" AFF℄INSTALL (2) NEW 2X2 LIGHTFIXTURES PER SCHEDULE INHALLWAY IN EXISTING CEILING(PATCH TO MATCH AT NEW WALLS)EEEEE℄EQ 1EQ 1℄6"℄EQ 1EQ 1℄6"℄EQ 1EQ 1℄6"℄EQ 1EQ 1℄6"℄EQ 1EQ 1℄6"BBB1. ALL NEW SPRINKLER HEADS TO BE CENTERED IN CEILING TILES. (COORDINATE LOCATIONS WITHFIRE PROTECTION PLAN AND ALL OTHER TRADES). ALL EXISTING SPRINKLER HEADS TO REMAIN.2. COORDINATE NEW CEILING WORK WITH ALL NEW AND EXISTING CEILING ITEMS, ACCESSORIES,AND SYSTEMS.3. COORDINATE WITH OWNER WHETHER ALL EXISTING EXHAUST GRILLES AND DIFFUSERS, EXITSIGNS, EMERGENCY LIGHT FIXTURES, SPEAKERS, SPRINKLERS, ETC ARE TO REMAIN OR TO BEUPGRADED AS PART OF THE PROJECT.4. CENTER ALL NEW ACOUSTICAL CEILING TILES IN BOTH DIMENSIONS IN ALL ROOMS SCHEDULEDTO RECEIVED NEW SUSPENDED ACOUSTICAL TILE, UNLESS SHOWN DIFFERENTLY ON DRAWINGS.5. SEE ELECTRICAL LIGHTING PLAN AND SCHEDULE FOR LIGHTING FIXTURES.6. ALL SUSPENDED CEILINGS SHALL BE EQUIPPED WITH SEISMIC PERIMETER CLIPS AT NEW TILESAPPROVED FOR SEISMIC CATEGORY "C". USE CEILING WIRE ASSEMBLY APPROVED FOR USE INANCHORING SUSPENSION WIRES TO SIDES OF CONCRETE RIBS AND BEAMS.7. USE HARDWARE FRIENDLY OPTIONS AT ALL LIGHT FIXTURES AND OTHER ACCESSORIES. GAPSBETWEEN FIXTURE TRIM AND REVEALS ARE NOT ACCEPTABLE.SUSPENDED ACOUSTICAL CEILING2'x4' LIGHT FIXTURE2'x2' LIGHT FIXTURERECESSED DOWNLIGHT FIXTURESURFACE MOUNTED WALL SCONCE LIGHT FIXTURECEILING MOUNTED EXIT SIGNWALL MOUNTED EXIT SIGN1'x4' LIGHT FIXTURESPRINKLER HEAD (CEILING OR WALL MOUNTED) - SEE FIRE PROTECTION DRAWINGSSECURITY CAMERAGYPSUM BOARD CEILING / SOFFITSUPPLY DIFFUSER - SEE HVAC DRAWINGSRETURN OR EXHAUST GRILLE - SEE HVAC DRAWINGSSCEILING MOUNTED SPEAKER2' UNDERCABINET LIGHT FIXTURE4' UNDERCABINET LIGHT FIXTUREBOX SOFFIT ABOVE CABINETRY (SEE ELEVATION FOR TYPE)PLASTIC LAMINATE CEILING / SOFFITMEP WORK TO BE DESIGN BUILDCEILING TYPECEILING HEIGHT ABOVE FINISH FLOOREXISTING CEILING TO REMAIN, PAINT CEILING WHITEEXISTING CEILING GRID TO REMAIN, UNO; RELAMP ALL EXISTING 2x4 AND 2x2 LIGHTFIXTURES WITH WITH LED LAMPS (TYPICAL OF PROJECT)CEILING MOUNTED SMOKE DETECTORDOME LIGHT WITH AUDIBLE LOCAL ALARMHFFSCEILING MOUNTED HEAT DETECTORUSG MARS CLIMA PLUS #86785, 24"x24" TEGULAR TILE, COLOR: WHITE WITH 15/16"TEE GRID SYSTEM, COLOR: WHITETYPE 1GYPSUM BOARD CEILING AND SOFFITS - SEE DETAILSTYPE 212SECORWAPWIRELESS ACCESS POINTLEGENDREFLECTED CEILING KEYED NOTESREFLECTED CEILING NOTESCEILING TYPE SCHEDULEXXXXXX1. GENERAL NOTESA. THE PLANS ARE DIAGRAMMATIC IN NATURE AND THEIR INTENT IS TO SHOW THE BASICREQUIREMENTS OF THE SYSTEM. THE INSTALLER SHALL FURNISH ALL MATERIALS,FIXTURES, WIRING, DEVICES, SUPPORT, DISCONNECT SWITCHES, AND OTHER REQUIREDEQUIPMENT NOT SPECIFICALLY INDICATED HEREIN, AND LABOR FOR A COMPLETE ANDOPERATING SYSTEM AS SPECIFIED HEREIN. THE INSTALLER IS RESPONSIBLE FOROBTAINING AND PAYING FOR ANY NECESSARY PERMITS AND APPROVALS, AND ANY OTHERCHARGES OR FEES.B. ALL ELECTRICAL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE NATIONALELECTRICAL CODE (NFPA 70), AND THE APPLICABLE STATE ELECTRIC CODE.C. CONTRACTOR SHALL GUARANTEE ALL LABOR AND MATERIALS FOR A PERIOD OF ONE (1)YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION.D. DO NOT SCALE DRAWINGS. SEE ARCHITECTURAL PLANS FOR EXACT LOCATIONS OFEQUIPMENT. ITEMS WHICH ARE NOT SPECIFICALLY LOCATED BY DIMENSION ON THEARCHITECTURAL PLANS SHOULD BE COORDINATED WITH THE ARCHITECT.E. ALL EQUIPMENT LISTED ON THE DRAWING IS SPECIFIED AS "OR APPROVED EQUAL" UNLESSINDICATED OTHERWISE. THE CONTRACTOR SHALL PROVIDE SUBMITTALS FOR ANYEQUIPMENT DIFFERENT FROM WHAT IS LISTED ON THE DRAWINGS FOR APPROVAL BY THEARCHITECT PRIOR TO INSTALLATION. FOR GENERAL EQUIPMENT WHICH IS NOT LISTED ONTHE DRAWINGS, SUBMITTALS ARE REQUIRED AS OUTLINED IN THE SPECIFICATIONS.F. FOR EQUIPMENT FURNISHED BY "OTHERS", THE ELECTRICAL CONTRACTOR SHALL RUN THEPOWER LINES TO EQUIPMENT DISCONNECT SWITCHES AND MAKE FINAL CONNECTION TOEQUIPMENT UNLESS INDICATED OTHERWISE. THE CONTROLS FOR SAID EQUIPMENT SHALLBE THE RESPONSIBILITY OF "OTHERS" UNLESS NOTED OTHERWISE. COORDINATE LOADSWITH OTHER TRADES AND VERIFY SAME.2. WIRINGA. ALL WIRING SHALL MATCH EXISTING BUILDING STANDARD UNLESS SPECIFICALLY INDICATEDOTHERWISE. ALL WIRING TO BE IN ACCORDANCE WITH NATIONAL ELECTRIC CODE &APPLICABLE STATE ELECTRIC CODE. ALL WIRING TO BE RUN CONCEALED. IN MOST CASENEW LIGHTS SHOWN ARE TO BE CONNECTED TO EXISTING CIRCUITS IN THE AREA.1. WIRING FOR CIRCUITS INDICATED TO BE CONNECTED TO THE EMERGENCY SYSTEMSHALL BE KEPT ENTIRELY INDEPENDENT OF OTHER WIRING AND SHALL NOT ENTER THESAME RACEWAY, BOX, CABINET, ETC. WITH OTHER WIRING. A SEPARATE WIRE ANDCONDUIT SYSTEM IS REQUIRED FOR THE EMERGENCY SYSTEM IDENTIFIED AS ANEMERGENCY SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE.3. RECEPTACLESA. ALL DUPLEX (QUADRAPLEX) RECEPTACLES TO BE MOUNTED 18" ABOVE FINISH FLOORUNLESS INDICATED OTHERWISE.4. SWITCHESA. LIGHTING SWITCHES SHALL BE RATED FOR 20 AMP 120/277 VOLTS.B. INSTALL WALL SWITCHES 48 INCHES (ON CENTER) ABOVE FLOOR, OFF POSITION DOWN.5. DATA/ TELEPHONE OUTLETA. ALL DATA/ TELEPHONE OUTLETS TO CONSIST OF FLUSH OUTLET BOX WITH CONCEALED 3/4"METAL CONDUIT RUN TO ABOVE SUSPENDED CEILING.B. TELEPHONE/ DATA WIRING TO BE ACCOMPLISHED BY OWNERS CONTRACTOR.6. SUPPORT REQUIREMENTSA. LIGHT FIXTURES TO BE SUPPORTED INDEPENDENT OF THE CEILING GRID SYSTEM. THEYSHALL BE SUPPORTED FROM THE BUILDING STRUCTURE WITH JACK CHAINS.7. MARKINGSA. MARK EXTERIOR OF ALL JUNCTION BOXES IN THE ELECTRICAL WIRING SYSTEM TO INDICATECIRCUIT NUMBER AND PANEL DESIGNATION OF ALL CIRCUITS CONTAINED WITHIN IT.8. FIRESTOPPINGA. THE INTEGRITY OF FIRE-RATED WALLS AND FLOORS, WHERE PENETRATIONS ARE MADEFOR THE PASSAGE OF CONDUIT, CABLES, ETC., MUST BE MAINTAINED.1. ALL PENETRATIONS MUST BE SLEEVED AND FIRE STOPPED WITH MATERIALS THAT AREUL CLASSIFIED AND FACTORY MUTUAL APPROVED FOR USE IN APPLICABLE RATEDASSEMBLY.9. PANEL BALANCINGA. THE ELECTRICAL CONTRACTOR SHALL BALANCE ALL NEW & EXISTING CIRCUITS ASREQUIRED AT ALL NEW & EXISTING PANELS.ELECTRICAL NOTES1. BIDS SHALL BE BASED ON THE LIGHTING FIXTURE SCHEDULE AND SPECIFICATIONS. REFER TOTHE ELECTRICAL SPECIFICATIONS FOR ADDITIONAL INFORMATION INCLUDING SUBSTITUTIONS.2. ALL FIXTURES SHALL BE UL LISTED.3. DRIVERS SHALL BE UL LISTED AND SHALL BE THE MANUFACTURER'S SPECIFIED DRIVER FOR THEFIXTURE OR SHALL BE VERIFIED COMPATIBLE BY BOTH THE DRIVER AND FIXTUREMANUFACTURERS.4. ALL FIXTURES SHALL BE COMMERCIAL GRADE WITH AN EXTENDED SERVICE LIFE TIME.5. ALL NECESSARY MOUNTING HARDWARE, HANGERS,BRACKETS, RAILS, YOKES, STEMS, CHAINS,ETC., SHALL BE FURNISHED AND INSTALLED.6. REFER TO ARCHITECTURAL DRAWINGS FOR SPECIFIC DETAILS, ARRANGEMENT, MOUNTINGHEIGHTS, CEILING CONSTRUCTIONS, ETC. ALL COLORS AND FINISHES SHALL BE VERIFIED BYTHE ARCHITECT.7. FIXTURES SHALL BE SEISMICALLY SUPPORTED AS REQUIRED BY THE APPLICABLE BUILDINGCODE.8. WIRE ALL BATTERY PACK UNITS (I.E. EXIT SIGNS AND EMERGENCY UNITS) TO LINE SIDE OFLOCAL LIGHTING BRANCH CIRCUIT.LIGHTING FIXTURE NOTESXMANUFACTURERTYPEFIXTURE DESCRIPTION LAMPSALITHONIA LIGHTINGMODEL #:2BLT2 40L ADP GZ1 LP835RECESSED 2'x2', CENTER FILL LED LIGHTLUMENS: 3300VOLTAGE: MVOLT (120-277V)DRIVER: STEP-LEVEL DIMMINGCOLORTEMPERATURE:3000KBCELECTRICAL FIXTURE SCHEDULEMANUFACTURERTYPEFIXTURE DESCRIPTION LAMPS6" WAFER DOWNLIGHT((8) W/ GWB TRIM & (2) W/ ACT TRIM)COLORTEMPERATURE:ADJUSTABLELITHONIA LIGHTINGMODEL #:WF6 LED 27K30K35K 90CRI MWDBRUCK, TITAN 1 PENDANT (4"Dx12"H)CHROME AND AMBER GLASS HOUSING& WHITE/WHITE CABLE AND CANOPYLED LAMPS2200KBRUCKMODEL #: LE26-806-CH-PWHWITH LMP-TB1030022K1 LAMPELOOPHOLE 52" LINEAR LEDSUSPENDED PENDANT FIXTUREBRUSHED ALUMINUM FINISH3000KWAC LIGHTINGMODEL #:PD-23852-FSPC 12 CEILING MOUNTTAMPER RESISTANT FIXTUREWITH 3 BARS EACH END3000KLITHONIAMODEL #:SPC 4OF 12IN NODIM 25W 3OKMVOLT OP SILBRUCK, TITAN 1 PENDANT (4"Dx12"H)CHROME AND AMBER GLASS HOUSING& WHITE/WHITE CABLE AND CANOPYLED LAMPS2200KBRUCKMODEL #: LE26-806-CH-PWHWITH LMP-TB1030022K1 LAMP7/29/2022 12:39 PMREFLECTED CEILINGPLAN & INTERIORELEVATIONSA151JRSEAL:MARK DATEISSUE-7/29/2022 PERMIT SETPROJECT NO:PROJECT ARCHITECT:PROJECT MANAGER:DRAWN BY:DATE:COPYRIGHT:22-004REKREK07/29/2022SHEET TITLE:CONSULTANT:64 GOTHIC STREET, SUITE 1NORTHAMPTON, MA 01060T 413.585.1512 F 413.586.7945www.haiarchitecture.comH AIArchitecture, Inc.1st Floor FinishesFlorence Bank58 Main StreetNorthampton, MA 01060Renovation for:PROJECT:PLANNORTHFIRST FLOOR RCPSCALE: 1/4" = 1'-0"