Loading...
Moran - EP Binder - FINALJ-Box INV #1 UTILTIY XMFR 120/240V, 1PHASE POINT OF COMMON COUPLING INVERTER INTEGRATED DC DISCONNECT INTERNET CONNECTION (EXISTING LAN) D 1 CBA2 2 23 - MODULES 23 - OPTIMIZERS 1 - OPTIMIZER PER MODULE STRING (1) = 11 OPTIMIZERS STRING (2) = 12 OPTIMIZERS ARRAY & STRING SIZING NOTES: ·THIS ARRAY HAS TWO DIFFERENT MODULE TYPES. ALL SOLD AS REC365AA. BE SURE TO LOCATE IN ARRAY TO HIDE MODULE GLASS DIFFERENCES AND MARK LOCATION ON DOCUMENTATION. ·IF ARRAY AND STRINGS ARE SPLIT BETWEEN MULTIPLE ROOF PLANES. USE EXTRA ROOF BOXES/CONDUIT TO JOIN ROOF PLANES/STRINGS AS NEEDED. ·MIN (8) MODULES PER STRINGS ·MAX (16) MODULES PER STRING (6,000 WATTS DC) ·KEEP MODULES WITHIN EACH STRING WITHIN 90° AZIMUTH OF EACH OTHER ·DO NOT EXCEED MAXIMUM DC POWER PER INVERTER POINT OF SOLAR INTERCONNECTION 3 3 E F 4 G EXISTING EQUIPMENT NEW EQUIPMENT OUTSIDE - ON ROOF INSIDE - HOSUE BASEMENT UTILITY SPACE OUTSIDE - HOUSE OUTSIDE - BUILDING SERVICEINSIDE - BASEMENT UTILITY SPACE SOLAR PV UTILITY ACCESSIBLE RAPID SHUTDOWN DISCONNECT M 200A-2PUTILITY METER 40A-2P LOADS LOADS LOADS MAIN LOAD CENTER A1 INVERTER GRID TRIP SETTINGS FREQUENCY & VOLTAGE - Per IEEE1547-2018 (2nd. ed.) Category II TRIP FUNCTIONS VOLTAGE / FREQUENCY CLEARING TIMES OVER VOLTAGE (OV2)1.2 0.16 OVER VOLTAGE (OV1)1.1 2 UNDER VOLTAGE (UV1)0.88 2 UNDER VOLTAGE (UV2)0.5 1.1 OVER FREQUENCY (OV2)62 0.16 OVER FREQUENCY (OV1)61.2 300 UNDER FREQUENCY (UF1)58.5 300 UNDER FREQUENCY (UF2)56.5 0.16 INTERCONNECTION CALCULATIONS ITEM VALUE POWER PHASE 1 Phase NOMINAL GRID VOLTAGE (V)240 INVERTER(S) MAX CONTINUOUS AC OUTPUT CURRENT PER PHASE (A)31.67 TOTAL MAX AC OUTPUT CURRENT WITH CON. USE (*1.25%)(A)39.58 INVERTER(S) INTERCONNECTION OCPD USED (A)40 MAIN OCP DISCONNECT (A)200 *MAIN PANEL BUSS AMPACITY (A)200 NEC ALLOWABLE (PANEL BUSS) BACKFEED AMPS AT 120% (A)40 *LOAD SIDE BREAKER INTERCONNECTION (IN MAIN LOAD CENTER) SYSTEM OVERVIEW 8.395 kW - DC SOLAR (Based on all REC365AA) 7.6 kW - AC SOLAR EQUIPMENT (20) REC365AA (3) REC380AA (23) P401, S440, P505 (1) SolarEdge 7.6kw HD-Wave w/ RGM / SE7600H-US000BNI4 UTILITY / AHJ / CODE: National Grid Town Of Florence 2020 NEC (MA)CONDUCTOR SCHEDULE & CALCULATIONS KEY DESCRIPTION QTY CONDUCTORS CONDUIT COND (A)TERM (A)REQ'D (A)OCP LENGTH VDROP% 1 DC - OPTIMIZER TO JBOX (PV SOURCE)4 #10 - PV WIRE/USE-2 90°C (CU) FREE AIR 32A 40A 18.75A 20A 50ft 0.48% EGC 1 #6 - BARE WIRE (CU) 2 DC - JBOX TO INVERTER 4 #10 - THHN/THWN-2 90°C (CU) .75" - EMT 32A 40A 18.75A 20A 100ft 0.97% EGC 1 #10 - THHN/THWN-2 90°C (CU) 3 AC - INVERTER OUTPUT 2 #8 - THHN/THWN-2 90°C (CU) .75" - EMT 55A 50A 39.58A 40A 40ft 0.82%EGC 1 #10 - THHN/THWN-2 90°C (CU) NEUTRAL 1 #8 - THHN/THWN-2 90°C (CU) 4 AC - SERVICE CONDUCTORS 2 #4/0 - XHHW/THWN 75°C (AL) CABLE - SER 180A 180A 166A 200A 15ft 0.25%EGC 1 #4 - XHHW/THWN 75°C (AL) NEUTRAL 1 #4/0 - XHHW/THWN 75°C (AL) EQUIPMENT SCHEDULE KEY QTY DESCRIPTION DATA / MAKE / MODEL A1 20 SOLAR MODULE REC, REC365AA, REC365AA, 365-Watts, 44.3V-Voc, 10.26A-Isc, (53.16V-Calculated Voc) A2 3 SOLAR MODULE REC, REC380AA, REC380AA, 380-Watts, 44.3V-Voc, 10.61A-Isc, (53.04V-Calculated Voc) NOTE: These are inventorty, using up stock. Sold as REC365AA B 23 POWER OPTIMIZER Solar Edge, P401, S440, P505 C 1 ARRAY MOUNTED JUNCTION BOX SOLADECK, NEMA-3R, ROOF JUNCTION BOX (2 STRING), 0799-5B D 1 SOLAR INVERTER SolarEdge 7.6kW HD-Wave w/ RGM, 1 Phase, 240V, 32A, 7.6kW AC (on grid) Max E 1 SOLAR, UTILITY ACCESSIBLE, RAPID SHUTDOWN DISCONNECT SqD, DU222RB, 60A, 240V, NON-Fusible, NEMA-3R (Outdoor), 2P, General Duty, Disconnect F 1 MAIN LOAD PANEL EXISTING: 1PHASE, 120/240V, 200A, MLO (EATON) NEED: (1) 40A-2P BRk EATON G 1 UTILITY SERVICE METER EXISTING: 1PHASE, 120/240V, 200A, 200A MAIN BRK, UG 311 WELLS STREET, SUITE B GREENFIELD, MA 01301 WWW.PVSQUARED.COOP 413-772-8788 SIZE: PV SQUARED SOLAR SCALE: DATE: BY: REV: MORAN FLORENCE 8 WARNER STREET FLORENCE, MA, 01062 ELECTRICAL SINGLE LINE 10/6/2022 MF NO SCALE 11x17 PV-E1 0 (PV) GENERAL NOTES ALL CONDUCTORS TO BE 600V MIN. RATED UNLESS OTHERWISE NOTED. ARRAY ELECTRICAL BONDING THROUGH LISTED RACKING GROUNDING SYSTEM. SOLAR PV EQUIPMENT CONNECTED TO SERVICE GROUNDING ELCTRODE SYSTEM INSTALLATION SUBJECT TO CHANGE BASED ON FIELD CONDITIONS INSTALLATION SUBJECT TO AHJ APPROVAL MAX RATE OF POWER EXPORT TO THE POCC IS LIMITED BY THE TOTAL INVERTER(S) AC RATING LABELS / VALUES PHOTOVOLTAIC DC DISCONNECT MAX DC VOLTS 600 OPERATING DC VOLTS 400 OPERATING DC AMPS (@INV)20.99 PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT 31.67 NOMINAL AC OPERATING VOLTAGE 240 AERIAL MAP NOT TO SCALEA SITE PLAN NOT TO SCALEB PROJECT INFORMATION: Project:MORAN NORTHAMPTON Address:8 WARNER ST. NORTHAMPTON, MA 01062 SYSTEM DETAILS Total System Size: 8.395 kW DC (Solar) 7.6 kW AC (Solar) Modules:(20) REC365AA (3) REC380AA Inverters:(1) SolarEdge 7.6kw HD-Wave w/ RGM Optimizers (23) SolarEdge P401, P485, P505, or S440 DESIGN CRITERIA Ground Snow Load 40 (psf) Design Wind Speed 117 (mph) Exposure Category B Risk Category II AUTHORITY HAVING JURISDICTION Building:Kevin Ross (413) 587-1239 Electrical:Roger Malo (413) 587-1244 Electrical Utility:NATIONAL GRID Code Ref NEC 2020 (MA) PROJECT NOTES MAIN LOAD CENTER SOLAR PV EQUIPMENT (BASEMENT) UTILITY SERVICE METER MAIN SERVICE DISCONNECT SOLAR PV DISCONNECT (OUTSIDE) 311 WELLS STREET, SUITE B GREENFIELD, MA 01301 WWW.PVSQUARED.COOP 413-772-8788 SIZE: PV SQUARED SOLAR SCALE: DATE: BY: REV: MORAN NORTHAMPTON 8 WARNER ST. NORTHAMPTON, MA 01062 SITE PLAN & PROJECT INFO. 10/31/2022 RTC NO SCALE 11x17 PV-M1 0 SOLAR ARRAY (ROOF) MODULE MOUNTED SNOW GUARD BOTTOM ROW ONLY STAGGER MODULE HEIGHTS BETWEEN ROWS TO REDUCE SNOW SHED experience performance 365 wp Power rec Alph black Series ELIGIBLE FOR www.recgroup.com Ref: PM-Rev- D 28 [1.1] 1721±2.5 [67.8±0.1] 802 [31.6]455 [17.9]975±2.5 [38.4±0.1]1016±2.5 [40 ±0.1]17 [0.7]45 [1.8] 1000 [39.4] 1200 [47.2] 11±0.2 [0.43 ±0.01]6.6±0.2 [0.26 ±0.01]20.5±0.5 [0.8±0.02] 30 [1.2] 22.5 [0.9] 621 ±3 [24.5 ±0.12] GR GR GRSpecifications subject to change without notice.CERTIFICATIONS WARRANTY LOW LIGHT BEHAVIOUR TEMPERATURE RATINGS* MA XIMUM RATINGS Irradiance (W/m) Typical low irradiance per formance of module at STC: Nominal Module Operating Temperature:°C (±°C) Temperature coe cient of PMAX:/°C Temperature coe cient of VOC:°C Temperature coe cient of ISC:°C *The temperature coe cients stated are linear values Operational temperature: ... + Maxim um system voltage: Desig n load (+): snow Maxim um test load (+): Pa (+ Pa ( )* Desig n load (-): wind Maxim um test load (-): Pa (+ Pa ( )* Max series fuse rating: A Max reverse current: A + Calculated using a safet y fac tor of * See installation manual for mounting instruc tions IEC IEC PID IEC Salt Mist Ammonia Resistance Fire Type Class Dynamic Mechanical Load Hailstone (mm) Cyclic Wind Load ISO :, ISO :, OHSAS :IEC Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All kW kW Product Warranty (yrs) Power Warranty (yrs) Labor Warranty (yrs) Power in Year Annual Degradation Power in Year See warrant y documents for details. Conditions apply. ELECTRICAL DATA Product Code*: RECx xxAA Black Power Output - PMA X (Wp) /+/+/+/+/+ Nominal Power Voltage - VMPP (V) Nominal Power Current - IMPP (A) Open Circuit Voltage - VOC (V) Short Circuit Current - ISC (A) Panel E ciency () Power Output - PMA X (Wp) Nominal Power Voltage - VMPP (V) Nominal Power Current - IMPP (A) Open Circuit Voltage - VOC (V) Short Circuit Current - ISC (A) Values at standard test conditions (STC: air mass AM , irradiance W/m ), temperature °F (C), based on a production spread with a tolerance of PMAX, VOC & ISC ±, irradiance W/m, temperature °F (°C), windspeed m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. GENERAL DATA Cell type: half-cut cells with REC heterojunction cell technolog y strings of cells in series Glass:in ( mm) solar glass with anti-reflection surface treatment Backsheet:Highly resistant polymeric construction (black) Frame:Anodized aluminum (black) Junction box :-part, bypass diodes, rated in accordance with IEC Connectors: Stäubli ( mm ) in accordance with IEC only when connected Cable: AWG ( mm PV wire, + in ( + m)in accordance with EN Dimensions: x x in ( x x mm) Weight: lbs (kg ) Origin:Made in Singapore STC NMOTREC ALPH BLACK SERIES PRODUCT DATASHEET REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, a ordable solar power in order to facilitate global energy transitions. backed by an exceptional low warranty claims rate of less than ppm. Founded in Norway in , REC employs people and has an annual solar panel capacity of GW. With over GW installed worldwide, REC is empowering more than million people with clean solar energy. REC Group is a Bluestar Elkem company with headquarters in Norway, operational headquarters in Singapore, and regional bases in North America, Europe, and Asia-Pacific. 85 90 95 100 105 200100 300 400 500 600 700 800 900 1000 Measurements in mm [in] Power Optimizer For North America S440, S500 25 YEAR WARRANTY PV power optimization at the module level Specifically designed to work with SolarEdge residential inverters Faster installations with simplified cable management and easy assembly using a single bolt Detects abnormal PV connector behavior, preventing potential safety issues* Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Flexible system design for maximum space utilization Compatible with bifacial PV modules Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading * Expected availability in 2022 solaredge.com POWER OPTIMIZER Power Optimizer For North America S440, S500 S440 S500 Unit INPUT Rated Input DC Power(1) 440 500 W Absolute Maximum Input Voltage (Voc) 60 Vdc MPPT Operating Range 8 - 60 Vdc Maximum Short Circuit Current (Isc) of Connected PV Module 14.5 15 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 % Overvoltage Category II OUTPUT DURING OPERATION Maximum Output Current 15 Adc Maximum Output Voltage 60 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1+/-0.1 Vdc STANDARD COMPLIANCE Photovoltaic Rapid Shutdown System NEC 2014, 2017 & 2020 EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant RoHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 129 x 153 x 30 / 5.07 x 6.02 x 1.18 mm / in Weight (including cables) 655 / 1.5 gr / lb Input Connector MC4(2) Input Wire Length 0.1 / 0.32 m / ft Output Connector MC4 Output Wire Length (+) 2.3, (-) 0.10 / (+) 7.54, (-) 0.32 m / ft Operating Temperature Range(3) -40 to +85 ˚C Protection Rating IP68 / Type6B Relative Humidity 0 - 100 % (1) Rated power of the module at STC will not exceed the power optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed (2) For other connector types please contact SolarEdge (3) For ambient temperature above +70°C / +158°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details PV System Design Using a SolarEdge Inverter Single Phase HD-Wave Three Phase for 208V grid Three Phase for 277/480V grid Minimum String Length (Power Optimizers) S440, S500 8 14 18 Maximum String Length (Power Optimizers) 25 50(4) Maximum Nominal Power per String 5700 (6000 with SE7600-US-SE11400-U) 6000 12750 W Maximum Allowed Connected Power per String (5) (Permitted only when the difference in connected power between strings is 1,000W or less) Refer to Footnote 5 One String 7200W 15,000W Two strings or more 7800W Parallel Strings of Different Lengths or Orientations Y (4) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement (5) If the inverters rated AC power ≤ maximum nominal power per string, then the maximum power per string will be able to reach up to the inverters maximum input DC power. Refer to: https://www.solaredge.com/ sites/default/files/se-power-optimizer-single-string-design-application-note.pdf (6) It is not allowed to mix S-series and P-series Power Optimizers in new installations © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or r egistered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: February 8, 2022 DS-000018-NA. Subject to change without notice. Power Optimizer For North America P370 / P400 / P401 / P485 / P505 25 YEAR WARRANTY PV power optimization at the module-level Specifically designed to work with SolarEdge inverters Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module- level monitoring Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) Module-level voltage shutdown for installer and firefighter safety solaredge.com POWER OPTIMIZER Power Optimizer For North America P370 / P400 / P401 / P485 / P505 Optimizer model (typical module compatibility) P370 (for higher-power 60 and 72-cell modules) P400 (for 72 & 96- cell modules) P401 (for high power 60 and 72 cell modules) P485 (for high-voltage modules) P505 (for higher current modules) INPUT Rated Input DC Power(1) 370 400 430 485 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 60 80 60 125(2) 83(2) Vdc MPPT Operating Range 8 - 60 8 - 80 8-60 12.5 - 105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc) 11 10.1 12.5 11 14 Adc Maximum DC Input Current 13.75 12.5 14.65 12.5 17.5 Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 80 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741, NEC/PVRSS Material UL94 V-0 , UV Resistant RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H) 129 x 153 x 27.5 / 5.1 x 6 x 1.1 129 x 153 x 33.5 / 5.1 x 6 x 1.3 129 x 153 x 29.5 / 5.1 x 6 x 1.16 129 x 159 x 49.5 / 5.1 x 6.3 x 1.9 129 x 162 x 59 / 5.1 x 6.4 x 2.3 mm / in Weight (including cables) 630 / 1.4 750 / 1.7 655 / 1.5 845 / 1.9 1064 / 2.3 gr / lb Input Connector MC4(3) MC4(3) MC4(3) Input Wire Length 0.16 / 0.5 m / ft Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 1.2 / 3.9 m / ft Operating Temperature Range (4) -40 to +85 / -40 to +185 ˚C / ˚F Protection Rating IP68 / Type6B Relative Humidity 0 - 100 % (1) Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed (2) NEC 2017 requires max input voltage be not more than 80V (3) For other connector types please contact SolarEdge (4) Longer inputs wire lengths are available for use. For 0.9m input wire length order P401-xxxLxxx (5) For ambient temperature above +85°C / +185°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details: https://www.solaredge.com/sites/default/files/se- temperature-derating-note-na.pdf PV System Design Using a SolarEdge Inverter(6)(7) Single Phase HD-Wave Single phase Three Phase for 208V grid Three Phase for 277/480V grid Minimum String Length (Power Optimizers) P370, P400, P401 8 10 18 P485, P505 6 8 14 Maximum String Length (Power Optimizers) 25 25 50 Maximum Power per String 5700(8) (6000 with SE7600-US - SE11400-US) 5250(8) 6000(9) 12750(10) W Parallel Strings of Different Lengths or Orientations Yes (6) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf (7) It is not allowed to mix P485/P505 with P370/P400/P401 in one string (8) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement (9) For 208V grid: it is allowed to install up to 6,500W per string when the maximum power difference between each string is 1,000W (10)For 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W © SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: February 10, 2022 DS-000044-NA. Subject to change without notice. Cut Sheet v1.0 See Description / Length 1.75 .46 .58 1.00 .62 1.33 1.67 XR10 Rail Cut Sheet 1 11.00 ALIGNMENT CIRCLEBONDING SPRING STOP TAB 0.61 1.29 0.88 Rail shown for reference 1) Bonded Splice, XR10 ITEM NO DESCRIPTION QTY IN KIT 1 SPLICE, XR10, MILL 1 Part Number Description XR10-BOSS-01-M1 Bonded Splice, XR10 Propery Value Material 6000 Series Aluminum Finish Mill Bonded Splice, XR10 v1.0 Cut Sheet See Description / Length 2.44 .58 1.25 2.34 1.99 .66 .46 APPROVED MATERIALS: 6005-T6, 6005A-T61, 6105-T5, 6N01-T6 (34,000 PSI YIELD STRENGTH MINIMUM) XR100 Rail v1.1 Cut Sheet v1.0 12.0 1 2 XR-100-SPLC-BD KIT, XR100 BONDED SPLICE 2) Screw, Self Drilling 1.93 1.24 .93 1) Splice, XR100, Mill 12" long .31 .42 .63 .15 #12-14 TYPE “B” THREAD XR-100 RAIL Property Value Material 6000 Series Aluminum Finish Mill Property Value Material 300 Series Stainless Steel Finish Clear XR100 Bonded Splice INVERTERSsolaredge.com Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Built-in module-level monitoring Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) Record-breaking 99% weighted efficiency Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp Fixed voltage inverter for longer strings UL1741 SA certified, for CPUC Rule 21 grid compliance Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020 per article 690.11 and 690.12 Small, lightweight, and easy to install both outdoors or indoors Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US 12-25 YEARWARRANTY MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4 OUTPUT Rated AC Power Output 3000 3800 @ 240V3300 @ 208V 5000 6000 @ 240V5000 @ 208V 7600 10000 11400 @ 240V10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V3300 @ 208V 5000 6000 @ 240V5000 @ 208V 7600 10000 11400 @ 240V10000 @ 208V VA AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)----Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V -16 -24 --48.5 A Power Factor 1, Adjustable - 0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V -5100 -7750 --15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(2)8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2)-9 -13.5 --27 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V98.5 @ 208V % Nighttime Power Consumption < 2.5 W (1) For other regional settings please contact SolarEdge support (2) A higher current source may be used; the inverter will limit its input current to the values stated SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US Single Phase Inverter with HD-Wave Technology for North America MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Metering, ANSI C12.20 Optional(3)Consumption metering Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown - NEC 2014, NEC 2017 and NEC 2020, 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1'' Maximum / 14-6 AWG 1'' Maximum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 1'' Maximum / 1-2 strings / 14-6 AWG 1'' Maximum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(4)˚F / ˚C Protection Rating NEMA 4X (Inverter with Safety Switch) (3) Inverter with Revenue Grade Meter P/N: SExxxxH-US000BNC4; Inverter with Revenue Grade Production and Consumption Meter P/N: SExxxxH-US000BNI4 . For consumption metering, current transformers should be ordered separately: SEACT0750-200NA-20 or SEACT0750-400NA-20. 20 units per box(4) Full power up to at least 50˚C / 122˚F; for power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2020/V01/ENG NAM. Subject to change without notice.