Moran - BP Binder - FINALAERIAL MAP NOT TO SCALEA SITE PLAN NOT TO SCALEB PROJECT INFORMATION: Project:MORAN NORTHAMPTON Address:8 WARNER ST. NORTHAMPTON, MA 01062 SYSTEM DETAILS Total System Size: 8.395 kW DC (Solar) 7.6 kW AC (Solar) Modules:(20) REC365AA (3) REC380AA Inverters:(1) SolarEdge 7.6kw HD-Wave w/ RGM Optimizers (23) SolarEdge P401, P485, P505, or S440 DESIGN CRITERIA Ground Snow Load 40 (psf) Design Wind Speed 117 (mph) Exposure Category B Risk Category II AUTHORITY HAVING JURISDICTION Building:Kevin Ross (413) 587-1239 Electrical:Roger Malo (413) 587-1244 Electrical Utility:NATIONAL GRID Code Ref NEC 2020 (MA) PROJECT NOTES MAIN LOAD CENTER SOLAR PV EQUIPMENT (BASEMENT) UTILITY SERVICE METER MAIN SERVICE DISCONNECT SOLAR PV DISCONNECT (OUTSIDE) 311 WELLS STREET, SUITE B GREENFIELD, MA 01301 WWW.PVSQUARED.COOP 413-772-8788 SIZE: PV SQUARED SOLAR SCALE: DATE: BY: REV: MORAN NORTHAMPTON 8 WARNER ST. NORTHAMPTON, MA 01062 SITE PLAN & PROJECT INFO. 10/31/2022 RTC NO SCALE 11x17 PV-M1 0 SOLAR ARRAY (ROOF) MODULE MOUNTED SNOW GUARD BOTTOM ROW ONLY STAGGER MODULE HEIGHTS BETWEEN ROWS TO REDUCE SNOW SHED Array 363" Roof 3871 2"Array 20334"Roof 233"Array 2011 2" (17') 2031 2" (17') 204"(14') 161" (14') 42" 81 8" 37 8" 1 3 16"40" 673 4" 93 4"2334"MODULE DETAIL SCALE: 1/4" = 1'-0"A ARRAY LAYOUT SCALE: 1/4" = 1'-0"B ROOF SPECIFICATIONS: Material: Asphalt Shingles Attachment Structure Decking/Rafters Pitch 34° Azimuth 250° MODULE SPECIFICATIONS: MODULE MODEL: REC365AA & REC380AA Dimensions:67.76" x 40" x 30mm Clamp Long Side:8 1/8"-23 3/4" Clamp Short Side:3 7/8"-9 3/4" RAIL SPECIFICATIONS Make & Model:Ironridge XR10 / XR100 Clamp Torque:80 in-lbs L-Foot Torque:250 in-lbs Max Cantilever:25" ATTACHMENT SPECIFICATIONS Bases/Flashing:SUNMODO NANOMOUNT Fasteners:DF #14-10 x 2" (DECKING) Sealant:CHEMLINK M-1 or Approved Alt. Max. Spacing:60" USE 48" TYP. SNOW GUARD TORQUE Safeguard Bar System:80-100 in-lbs Safeguard Bar:110-120 in-lbs ARRAY NOTES 1.Framing and attachment locations to be verified on site. 2.Bases are staggered to distribute point loading except at edges of array. 3.5th Screw allowed if one screw does not make solid connection; min. 4 screws must be solid. 4.Additional or alternative bases may be used to meet actual roof conditions. 5.Ironridge Rail Gap Spacing: 5.1.3/8" Horizontal Spacing 5.2.1/4" Vertical Spacing 311 WELLS STREET, SUITE B GREENFIELD, MA 01301 WWW.PVSQUARED.COOP 413-772-8788 SIZE: PV SQUARED SOLAR SCALE: DATE: BY: REV: MORAN NORTHAMPTON 8 WARNER ST. NORTHAMPTON, MA 01062 ARRAY LAYOUT & ROOF DATA 10/31/2022 RTC AS SHOWN 11x17 PV-M2 0 RAFTERS 16" OC OSB DECKING PLACE (3) REC380AA HERE TO MINIMIZE VISIBILITY SUNMODO NANOMOUNT BASES INSTALL ON DECKING 4 SCREWS PER BASE 48" OC TYP. MODULE MOUNTED SNOW GUARD BOTTOM ROW ONLY STAGGER MODULE HEIGHTS BETWEEN ROWS TO REDUCE SNOW SHED RAIL VSE Project Number: U1898.0092.221 October 18, 2022 PV Squared 311 Wells St. Ste. B Greenfield, MA 01301 REFERENCE: Moran - Northampton Residence: 8 Warner Street, Northampton, MA 01062 PV Squared Project: MOFL23092022R Solar Array Installation To Whom It May Concern: We have reviewed the existing structure at the above referenced site.The purpose of our review was to determine the adequacy of the existing structure to support the proposed installation of solar panels on the roof as shown on the panel layout plan. Based upon our review, we conclude that the existing structure is adequate to support the proposed solar panel installation. Design Parameters Code: Massachusetts State Residential Code (780 CMR Chapter 51, 9th Edition (2015 IRC)) Risk Category: II Design wind speed, Vult: 117 mph (3-sec gust) Wind exposure category: C Ground snow load, Pg: 40 psf Flat roof snow load, Pf: 35 psf Existing Roof Structure Roof structure: 2x10 rafters @ 16" o.c. Roof slope: 36° Conclusions Based upon our review,we conclude that the existing structure is adequate to support the proposed solar panel installation. See attached calculations. The solar array will be flush-mounted (no more than 10"above the roof surface)and parallel to the roof surface.Thus,we conclude that any additional wind loading on the structure related to the addition of the proposed solar array is negligible. Increases in lateral forces less than 10%are considered acceptable.Thus the existing lateral force resisting system is permitted to remain unaltered. 651 W. Galena Park Blvd., Ste. 101 / Draper, UT 84020 / T (801) 990-1775 / F (801) 990-1776 / www.vectorse.com VSE Project Number: U1898.0092.221 Moran - Northampton Residence 10/18/2022 Limitations Installation of the solar panels must be performed in accordance with manufacturer recommendations.All work performed must be in accordance with accepted industry-wide methods and applicable safety standards.The contractor must notify Vector Structural Engineering,LLC should any damage,deterioration or discrepancies between the as-built condition of the structure and the condition described in this letter be found.The use of solar panel support span tables provided by others is allowed only where the building type,site conditions,site-specific design parameters,and solar panel configuration match the description of the span tables.Connections shall be staggered so as not to overload any existing structural member.The design of the solar panels,solar racking (mounts,rails,etc.),the connection of the racking to the roof and electrical engineering is the responsibility of others.Waterproofing around the roof penetrations is the responsibility of others.Vector Structural Engineering assumes no responsibility for improper installation of the solar array.Vector Structural Engineering shall be notified of any changes from the approved layout prior to installation. VECTOR STRUCTURAL ENGINEERING, LLC 10/18/2022 _______________________________________________________ Jacob Proctor, P.E. MA License: 54953 - Expires: 06/30/2024 Project Engineer Enclosures JSP/hub 10/18/2022 651 W. Galena Park Blvd., Ste. 101 / Draper, UT 84020 / T (801) 990-1775 / F (801) 990-1776 / www.vectorse.com experience performance 365 wp Power rec Alph black Series ELIGIBLE FOR www.recgroup.com Ref: PM-Rev- D 28 [1.1] 1721±2.5 [67.8±0.1] 802 [31.6]455 [17.9]975±2.5 [38.4±0.1]1016±2.5 [40 ±0.1]17 [0.7]45 [1.8] 1000 [39.4] 1200 [47.2] 11±0.2 [0.43 ±0.01]6.6±0.2 [0.26 ±0.01]20.5±0.5 [0.8±0.02] 30 [1.2] 22.5 [0.9] 621 ±3 [24.5 ±0.12] GR GR GRSpecifications subject to change without notice.CERTIFICATIONS WARRANTY LOW LIGHT BEHAVIOUR TEMPERATURE RATINGS* MA XIMUM RATINGS Irradiance (W/m) Typical low irradiance per formance of module at STC: Nominal Module Operating Temperature:°C (±°C) Temperature coe cient of PMAX:/°C Temperature coe cient of VOC:°C Temperature coe cient of ISC:°C *The temperature coe cients stated are linear values Operational temperature: ... + Maxim um system voltage: Desig n load (+): snow Maxim um test load (+): Pa (+ Pa ( )* Desig n load (-): wind Maxim um test load (-): Pa (+ Pa ( )* Max series fuse rating: A Max reverse current: A + Calculated using a safet y fac tor of * See installation manual for mounting instruc tions IEC IEC PID IEC Salt Mist Ammonia Resistance Fire Type Class Dynamic Mechanical Load Hailstone (mm) Cyclic Wind Load ISO :, ISO :, OHSAS :IEC Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All kW kW Product Warranty (yrs) Power Warranty (yrs) Labor Warranty (yrs) Power in Year Annual Degradation Power in Year See warrant y documents for details. Conditions apply. ELECTRICAL DATA Product Code*: RECx xxAA Black Power Output - PMA X (Wp) /+/+/+/+/+ Nominal Power Voltage - VMPP (V) Nominal Power Current - IMPP (A) Open Circuit Voltage - VOC (V) Short Circuit Current - ISC (A) Panel E ciency () Power Output - PMA X (Wp) Nominal Power Voltage - VMPP (V) Nominal Power Current - IMPP (A) Open Circuit Voltage - VOC (V) Short Circuit Current - ISC (A) Values at standard test conditions (STC: air mass AM , irradiance W/m ), temperature °F (C), based on a production spread with a tolerance of PMAX, VOC & ISC ±, irradiance W/m, temperature °F (°C), windspeed m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. GENERAL DATA Cell type: half-cut cells with REC heterojunction cell technolog y strings of cells in series Glass:in ( mm) solar glass with anti-reflection surface treatment Backsheet:Highly resistant polymeric construction (black) Frame:Anodized aluminum (black) Junction box :-part, bypass diodes, rated in accordance with IEC Connectors: Stäubli ( mm ) in accordance with IEC only when connected Cable: AWG ( mm PV wire, + in ( + m)in accordance with EN Dimensions: x x in ( x x mm) Weight: lbs (kg ) Origin:Made in Singapore STC NMOTREC ALPH BLACK SERIES PRODUCT DATASHEET REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, a ordable solar power in order to facilitate global energy transitions. backed by an exceptional low warranty claims rate of less than ppm. Founded in Norway in , REC employs people and has an annual solar panel capacity of GW. With over GW installed worldwide, REC is empowering more than million people with clean solar energy. REC Group is a Bluestar Elkem company with headquarters in Norway, operational headquarters in Singapore, and regional bases in North America, Europe, and Asia-Pacific. 85 90 95 100 105 200100 300 400 500 600 700 800 900 1000 Measurements in mm [in] Cut Sheet v1.0 See Description / Length 1.75 .46 .58 1.00 .62 1.33 1.67 XR10 Rail Cut Sheet 1 11.00 ALIGNMENT CIRCLEBONDING SPRING STOP TAB 0.61 1.29 0.88 Rail shown for reference 1) Bonded Splice, XR10 ITEM NO DESCRIPTION QTY IN KIT 1 SPLICE, XR10, MILL 1 Part Number Description XR10-BOSS-01-M1 Bonded Splice, XR10 Propery Value Material 6000 Series Aluminum Finish Mill Bonded Splice, XR10 v1.0 Cut Sheet See Description / Length 2.44 .58 1.25 2.34 1.99 .66 .46 APPROVED MATERIALS: 6005-T6, 6005A-T61, 6105-T5, 6N01-T6 (34,000 PSI YIELD STRENGTH MINIMUM) XR100 Rail v1.1 Cut Sheet v1.0 12.0 1 2 XR-100-SPLC-BD KIT, XR100 BONDED SPLICE 2) Screw, Self Drilling 1.93 1.24 .93 1) Splice, XR100, Mill 12" long .31 .42 .63 .15 #12-14 TYPE “B” THREAD XR-100 RAIL Property Value Material 6000 Series Aluminum Finish Mill Property Value Material 300 Series Stainless Steel Finish Clear XR100 Bonded Splice 9 8 7 6 5 4 3 2 1 ITEM NO.PART CODE DESCRIPTION QTY 1 SG-BRKT MILL SOLAR SG-BRKT 3.75X1.25X.5-AL 1 2 T-NUT SNOWMAX SNOWMAX T-NUT 1 3 SSM-R2-TAPE V2852 .063X1.3X1.3 DIECUT SQ 1 4 W-STR SS-.25 SS STAR WASHER .25 ID 1 5 B-HX SS-.25-20X3 SS HEX TAP BOLT .25-20X3 1 6 B-FL SS-.313-18X1 SS FLANGE BOLT .313-18X1 1 7 SOLAR SG-CLIP SOLAR SG-CLIP-1.5-AL 1 8 ALPINE SIMGUARD-BAR ALPINE SIMPLEGUARD BAR-AL AS NEEDED 9 ALPINE SIMGUARD-CI69 SIMPLEGUARD 2.365" CI BLACK AS NEEDED 1:2 289 Harrel StreetMorrisville, VT 05661Phone: 1.888.766.4273Fax: 1.888.766.9994Email: Info@alpinesnowguards.com Assembly Sheet - SOLAR SG-BRKT 4/5/2021 Installation to be completed in accordance with manufacturer's written specifications and installation instructions.1.See spec sheet or contact manufacturer for detailed material, finishes, and configuration options.2.Contact manufacturer for detailed layout.3.Do not scale drawings.4.Subject to change without notice.5.For patent information, visit our 6. Scale: Patent Page. Cut Sheet NanoMount NanoMount Material: Aluminum Finish: Black Powder Coating Material: USWR Gasket with Adhesive Details are subject to change without notice D10214-V003 Dimensions shown are inches (and millimeters) NanoMount NanoMount Gasket Description K50058-BK1 Part Number NanoMount USWR Gasket Cut Sheet NanoMount Lag Bolt Details are subject to change without notice Material: Stainless Steel Finish: Clear 2.Sealing Washer .26ID X .50X .125 Material: EPDM + Stainless Steel 1.Self-Tapping Screw, #6.3 X 76 Details are subject to change without notice D10214-V003 Dimensions shown are inches (and millimeters)Dimensions shown are inches (and millimeters) Material: Stainless Steel Finish: Clear 2. Sealing Washer .33ID X.75X.157 Material: EPDM + Stainless Steel 1.. Hex Lag Bolt M8X115, DIN 571, 304 Material: Stainless SteelMaterial: Stainless SteelMaterial: Stainless Steel Lag Bolt Assembly Decking Screw Assembly NanoMount Decking Screw Decking Screw Assembly Self-Tapping Screw, #6.3 X 76 Sealing Washer .26ID X .50X .125 Description K50049-BK1 Part Number K50055-BK1 Lag Bolt Assembly Hex Lag Bolt M8X115, DIN 571, 304S Sealing Washer .33 ID X .75 X .157