Loading...
24D-172 (7) BP-2022-1358 210 STATE ST COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 24D-172-001 CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2022-1358 PERMISSION IS HEREBY GRANT, D TO: Project# 2022 SOLAR Contractor: License: Est. Cost: 16000 EMPOWER ENERGY SOLUTIONS 019944109!44 Const.Class: Exp.Date: 12/01/202312/01/2023 Use Group: Owner: Lot Size (sq.ft.) Zoning: URC Applicant: EMPOWER ENERGY SOLUTIONS Applicant Address Phone: Insurance: 300LD KINGS HWY S#1001 (475)221-2356 WC533SB2191Q011 DARIEN, CT 06820 ISSUED ON: 10/19/2022 TO PERFORM THE FOLLOWING WORK: INSTALL 12 PANEL 4.26 KW ROOF MOUNT SOLAR SYSTEM POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIO ATION OF ANY OF ITS RULES AND REGULATIONS. Signature: • it • . V.. . I Fees Paid: $ ?� 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Office of the Building Commissioner 1a Cf ,� The Commonwealth of Massachuset4 Board of Building Regulations and.Standard.O 1 FOR Massachusetts State Building Code, 7801CMRCr ' 9 ln� /MUN-CIPALITY L . ,,,2 I USE Building Permit Application To Construct,Repair,R&riov emolish a Revised Mar 2011 One-or Two-Family Dwelling �� :'�Na�;� ' c mispEcr / This Section For Official Use Only - ��� s oNs 1 Buildin Permit Number: 2,A AA-el 35'g Date Applied: 10/11/2022 I s � — 1 Z�, os // iv q•ZOZ Building Official(Print Name) Signature Date SECTION 1: SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 210 State St., Northampton MA 01060 :2•-1 9 17)- 1.1 a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone: _ Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Schulman,Joshua Northampton, MA 01060 Name(Print) City,State,ZIP 210 State St. 6467344616 yschulman@gmail.com No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition 0 Demolition 0 Accessory Bldg. 0 Number of Units Other 0 Specify: Brief Description of Proposed Work': Installation of a safe and code compliant,grid-tied PV solar system on an existing residential roof. 12 panels.4.26 kw SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1. Building $ 16,000 1. Building Permit Fee: $ Indicate how fee is determined: 2.Electrical $ ❑Standard City/Town Application Fee ❑Total Project Cost'(Item 6)x multiplier x 3. Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees:1llll Check No. 1(U 7 Check Amount4i 14 Cash Amount: 6. Total Project Cost: $ 0 Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) 1 nqq44 12/2/2023 Lando Bates License Number Expiration Date Name of CSL Holder List CSL Type(see below) 51 Assabet Dr No.and Street Type Description Northborough, MA 01532-2600 U Unrestricted(Buildings up to 35,000 cu.ft.) City/Town,State,ZIP R Restricted 1&2 Family Dwelling M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 774-249-1687 Lando.B@empowerenergy.co I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 198351 Empower Energy Solution 4/05/2024 HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 30 OLD KINGS HWY S SUITE 1001 operations@empowerenergy.co No.and Street Email address DARIEN ,CT 06820 (475)221-2356 City/Town,State,ZIP Telephone SECTION 6:WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes No . 0 SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize to act on my behalf,in all matters relative to work authorized by this building permit application. Q 10/11/2022 Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. 10/11/2022 Print Owner's or Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A. Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq. ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" The Commonwealth of Massachusetts ►� t, l=t� Department of Industrial Accidents _vs!: l- is) 1 Congress Street,Suite 100 • _�;i= � Boston, MA 02114-2017 www.mass.gov/dia _rtij. Mockers'Compensation Insurance Affidavit:it:Builders/ContractorsIEIectricians/Plumbers. TO BE FILED WITH'tHE AUTHORITY. Applicant Information Please Print Legibly Name(Business Organtzationrindtvidual): Empower Energy Solutions Inc Address: 30 OLD KINGS HWY S#1001 City/State/Zip: DARIEN CT 06820-4551 Phone#: 475-221-2356 Are you an employer?Cheek the appropriate bus: Type of project(required): 10 I. I am a employer with employees(full andr'or part-time).• ® 7. 0 New construction 20 1 am a sole proprietor or partnership and have no employees working for me in any capacity.[No workers'comp.insurance 8. Remodeling ca 30 I am a homeowner doing all wart myself.[No workers'comp.assurance ni(wr d.)• 9. ❑ Demolition 4.0 I am a hm oeowner and will be hiring crxttractors to conduct all work on my property_ I will 10 D Building additio .more that all contractors either have woekets'compensation inlunmct or an sine II.0 Electrical repairs or additions proprietors wilt no employees. 12.0 Plumbing repairs or additions 50 I am a general contractor and I have hind the sub-contractors listed on the attached sheet. These sub-contractors lure ernpluyers and have workers'comp.insurance.: 13 Q Roof repairs 6.0 We are a corporation and its officers have exercised their right of exemption per MGL c. 14.0 Other PV Solar,Installation 1 2.11(4).and we have no employees.[No workers'comp.insurance required.) *Any applicant that checks box#1 mug also fill out the section below showing their workers'compensation policy information f Homeowners who submit this affidavit indicating they arc doing all work and then hire outside contractors Inuit subnut a ness affidao it indic-i ing such. Contractors that check this box must attached an additional sheet showing the name of the subcontractor,and state whether or not those entities have employees. it the subcontractors base employees.they must pros ide their workers'comp.puhcy nwnber. I am an employer that is prot'iding workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: LM Insurance Corporation _ Policy#or Self-ins.Lic.#: WC533SB2191Q011 Expiration Date:11/03/2022 Job Site Address: 210 State St City/State/Zip: Northampton, MA 01060 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to S I.500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties ofpedal.),that the information provided above is true and correct ` -- `:> 10/11/2022 Signature: Date: Phone#: (475)221-2356 Official use only. Do not write in this arra.to be completed by city or town official. ('ity or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.(.'ity/Town Clerk 4.Electrical Inspector 5. Plumbing Inspector 6.Other Contact Person: Phone#: DATE(MM/DDIYYYY) ACCORD AC� CERTIFICATE OF LIABILITY INSURANCE 12/03/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Ann-Marie Kahanowitx R S GILMORE INSURANCE AGENCY INC INCNN, ): (508)699-7511 FAX No): ADDRESS: amkahanowitz@rsgilmore.com PO Box 126 INSURER(S)AFFORDING COVERAGE NAIC NORTH ATTLEBORO MA 02761 INSURER A: LM INS CORP 33600 INSURED INSURER B EMPOWER ENERGY SOLUTIONS INC INSURER C: INSURER D: 10 RAMBLEWOOD DRIVE INSURER E: ROCKY HILL MA 06067 INSURER F: COVERAGES CERTIFICATE NUMBER: 722376 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXPM/ LIMITS LTR INSR WVD POLICY NUMBER (MDD/YYYY) (MM/DD/YYYYI COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ DAMAGE TO RENTED CLAIMS-MADE OCCUR PREMISES(Ea occurrence) $ MED EXP(Any one person) $ N/A PERSONAL&ADV INJURY $ GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ POLICY PRO- CT LOC PRODUCTS-COMP/OP AGG $ OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ (Ea accident) ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED N/A BODILY INJURY(Per accident) $ AUTOS AUTOS HIRED AUTOS NON-OWNED PROPERTY DAMAGE AUTOS (Per accident) UMBRELLA UAB OCCUR EACH OCCURRENCE $ EXCESS LIAR CLAIMS-MADE N/A AGGREGATE $ DED RETENTION$ $ WORKERS COMPENSATION X PER 0TH- AND EMPLOYERS'LIABILITY Y/N STATUTE ER ANA OFF CER/MEMBER EXCLUDED?ECUTIVE N/A N/A NIA WC533SB2191Q011 11/03/2021 11/03/2022 E.L.EACH ACCIDENT $ 500,000 (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 500,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 500,000 N/A DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Workers'Compensation benefits will be paid to Massachusetts employees only.Pursuant to Endorsement WC 20 03 06 B,no authorization is given to pay claims for benefits to employees in states other than Massachusetts if the insured hires,or has hired those employees outside of Massachusetts. This certificate of insurance shows the policy in force on the date that this certificate was issued(unless the expiration date on the above policy precedes the issue date of this certificate of insurance). The status of this coverage can be monitored daily by accessing the Proof of Coverage-Coverage Verification Search tool at www.mass.gov/Iwd/workers-compensation/investigations/. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Empower Energy Solutions Inc ACCORDANCE WITH THE POLICY PROVISIONS. 10 Ramblewood Drive AUTHORIZED REPRESENTATIVE r i Rocky Hill CT 06067 Daniel M.Cr y,CPCU,Vice President—Residual Market—WCRIBMA ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs & Business Regulation Registration valid for individual use only before the HOME IMPROVEMENT CONTRACTOR expiration date. If found return to: TYPE: Out of State Corporation Office of Consumer Affairs and Business Regulation Registration Expiration 1000 Washington Street - Suite 710 198351 04/05/2024 Boston, MA 02118 EMPOWER ENERGY SOLUTIONS INC - ASIM HAFEEZ ! . 30 OLD KINGS HWY S` c 4 `%, - SUITE 1001 �� DARIEN, CT 06820 Undersecretary Not valid without signature Name Name: Lando Bates Address: 51 Assabet Drive Northborough, MA 01532 Licenses Eligible for Processing Building Licenses License Type Construction Supervisor License Status: Active License Number: CS-109944 Expiration Date 12/1/2023 Engineering Licenses Check Status License Type Hoisting Engineer License Status: Active License Number: HE-196329 Expiration Date 12/1/2021 Empower Energy Solutions Inc HOMEOWNERS AUTHORIZATION FORM Addendum to Contract I, Joshua Schulman (Print Full Legal Name) am the owner of the property located at address: 210 State St Northampton MA 01060 (Print Full Address) I hereby authorize Empower Energy Solutions Inc to act as my Agent for the limited purpose of applying for and obtaining local building, electrical and other permits from the Authority Having Jurisdiction as required for the installation of a Photovoltaic System located on my Property. Customer Signature: Electronic Signature Accepted/Addendum to Contract Date: 09/ 18/2022 Signature: AsZi4Siaeh.4.. Doc ID:ab61a404d9ff284a14985e9250f6a2b8cd9116dc ��' LEGEND . W , E I S SCALE:1•=16" M UTILITY METER liNvI INVERTER qCI AC DISCONNECT o = ° 0 [1115P. MAIN SERVICE PANEL u- LB DC JUNCTION BOX W P MONITORING UNIT DRIVEWAY W D DISTRIBUTION PANEL LC LOAD CENTER ATS AUTOMATIC TRANSFER SWITCH CONDUIT y WYtH OF �' s., FENCE • L It tipnd 10/6/2022 JOB NUMBFR•1598 UTILITY NG OWNER: DESCRIPTION: nest VD ��� SCHt1LMAN,JOSHUA - SCHULMAN RESIDENCE MS PV2 E AP !.WER RAAC4Q G:IRONI�OGEXR 100 UTILITY ACC #50732-97O83 210 STATE ST 4.26 kW DC ROOF SOLAR SYSTEM REVIEW BY: ENf PGV 50LUtI0N5 MS MODULES:(12)LONG!LR4-60FPB355M NORTHAMPTON,MA.01060 3.80 kW AC "Ev DATE WNERTB (1)SOLAREDGE INVERTER SE380014.US(3.80KW) (646)734-4616 BBvaua: P OEMIwe mreww N LEGEND YY all`+ E ROOF 8 _ - RAFTERS SCALE:1'=10' RAIL MOUNT M P 1 0® OBSTRUCTION (12)MODULES TOTAL PENETRATION COUNT ie 0 Ulik MGM. IINIKEMINI "'`•s. CONCRETE TAE D 1111111111 TYPE {13TORIE4 __ `'© n •ii'ii'ijjj- •1 «;OF JUNCTION BOX "— MAIN SERVICE PANEL I �� wy'h ��i ! CONDUIT UTILITY METER N : INVERTER AC SMART DISCONNEC METER T ! \9'9', 'i., -%ite- AC DISCONNECT Bond 10/6/2022 ROOF LEAD SIGN OFF: JOB NUMBER:1598 UTILITY:NG DESIGNED°" tAOE — SCHULMAN,JOSHUA SCHULMAN RESIDENCE __IBIS P\/3210 STATE ST 4.26 kW DC ROOF SOLAR SYSTEM YBY MODULES(12)LONGILR4-60HPB36NN NORTHAMPTON,MA.01060 3.80 kW AC MS VER :(1j$aAF INVERTER (g,80 KW) (646)734-4616 REY '�'� N wenn PAGE WAIL ARRAY DETAIL 12'-1" • 11 7 / 1'4• - OF • • • •No. t � y 11' S 1 Signed 10/6/2022 3' ! I SOLAR MODULE -- 1'-4" / // 10' SLATE PLATE FLASHING ---". i MP1 SIDE VIEW NTS RAFTERS:2X6 @ 24"O.G. CONCRETE TILE SLATE ROOF -- STANDOFF MAX SPAN:-10'-9" Si SCALE NTS 2X6 NOMINAL JOB NUMBER:15®8 UiLRY:NG malt DESCRIPTOR SCHULMAN RESIDENCE °TDB" PAGE SCHULMAN,JOCHUA MS EAAPL W I�i�I EP RAMING:IRODGEXR-100 U IUT1rACCTN M73287°83 210 STATE ST 4.26 kW DC ROOF SOLAR SYSTEM w ar: PV4 ENERGY SOLUTIONS MODULES: NORTHAMPTON,MA.01060 3.80 kW AC REV: DATE INVERTER:(1)SOLAREDGE INVERTER SE390013US(180 KW) (646)734-4616 anv2= PACE NAME STRUCTURAL VIEWS AC.- BRA - .F MIIICN - EARTH GROUND ---- DEC INVERTER OUTPUT CURRENT(A)- 16 INVERTER BACKFEED(A)- 20 BIC 120240V SINGLE PHASE MSP RATING A 200 OVERHEAD UTILITY SERVICE MAIN BREAKER RATING(A)- 200 NI MAX BACKFEED(AN 40 TIE IN: LST 11111110(14011 . 7 UNE SIDE TAP 44 BOA AC DISCONNECT (N)BOA AC DISCONNECT (N)SOLADECK -FUSIBLE.LOCKABLE -FUSIBLE.LOCKABLE ra. -20A FUSES (N)IAA SMARTIETER -20A FUSES JUNCTION BOX • _ -UNFUSED (I5(1TJ LOIK30B61A480HPB-35544 355W PV MODULES - E.-- -GROUNDED (12)801ME0(iE P3T0 POWER OPT1L�Rb 20A /// 12 /// • -----TAM LOAD ,1 l i 1 I 200 A/7P 1 V 0 § (E)LOWS --- I ---J 1 GROUND ELECTRODE ELEC. LEAD AMOIR,TI•NN2 AWOR.TIMN2 MGM.THAW AWG MO.PV WIFE IWWHE T/11012,ROCIDEC AMMO,T11WHB.EOC/OEC AMOK T1WN2.EOCAEC AWO MO,,TTMN42,EGC SIGN OFF: CONDUIT.W BIT CONCUR,W oar CONDUIT.OW Off CONCUR,W EMT JOBNUMBER 1598 UAI�'!� O""E'E DEBCRPrlCW BE HEWESr PAGE Se STATE ,JOSHUA kW DC OF RESIDENCE MS PV5 MVP moon p(E)_100 Ui1LITYACCTN 60732-97083 210 STATE ST 4.26 kW DC ROOF SOLAR SYSTEM REVIEW BY kE Y SOLUTIONS MODULES:(12)LONGILR4-60FIPB35&Hl NORTHAMPTON,MA.01060 3.80 kW AC MS DAB INVERTER:(1)SOLAR INVERTER SE380011{JS(3•80 (646)734-4616 ROAR 2 PAGE NAME MOLE U NE NOTE: NEC 690.17(E) BACKGROUND AND LETTERING COLORS FOR SIGNAGE/LABELS See Figure 690.1(b)diagrams for location in system SHALL COMPLY WITH(IN ORDER OF PRIORITY)AHJ&FIRE Disconnects PV from all other wiring systems DEPARTMENT AMENDMENTS,STATE CODE,AND ANSI Installed in a readily accessible location GUIDELINES.THIS PAGE IS INTENDED OR SIGNAGE/LABEL Permanently marked: PV SYSTEM DISCONNECT, or equivalent VERBIAGE ONLY. Where line/load may be energized in open (off) position: OUTSIDE LABELING OF SYSTEM COMPONENTS AND METERS IS Marked with the following or equivalent TO BE DONE IN A WAY SUITABLE FOR THE ENVIRONMENT IN NEC 690.31 (D) 2; 2012 IFC 605.11 WHICH THE EQUIPMENT IS INSTALLED.NO STICKERS ARE On or in a building, unless location/purpose is evident PERMITTED• WARNING RacewaysMinimum 3/8", enclosuresCAPS , every Whiteon R 10', suitable ed forReflective environment 2020 NFPA 70, NEC 690.53 , DIRECT-CURRENT PHOTOVOLTAIC POWER SOURCE Maximum system voltage calculated in accordance with 690.7 ELECTRICAL SHOCK HAZARD • At one of the following locations: DO NOT TOUCH TERMINALS • DC PV system disconnect TERMINALS ON BOTH THE LINE AND LOAD PV system electronic power conversion equipment SIDE MAY BE ENERGIZED IN THE OPEN A R Ni I N G •• Distribution equipment associated with the PV system POSITION PHOTOVOLTAIC POWER SOURCE MAXIMUM VOLTAGE ( I 1 j MAXIMUM CIRCUIT CURRENT I • NEC 705.12(D)(2)(b) MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER PLACE THIS LABEL AT P.O.C. TO SERVICE OR DC-TO-DC CONVERTER I DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL (AND 2020 NFPA 70, NEC 690.56(c) OF INSTALLED) l SUBPANEL IF APPLICABLE)) LOCATED AT EACH SERVICE EQUIPMENT LOCATION 2020 NFPA 70, NEC 690.54 WHERE PV IS CONECTED"OR APPROVED READLY VISIBLE LOCATION INTERACTIVE SYSTEM POINT OF INTERCONNECTION WARNING SHALL INCLUDE SIMPLE DIAGRAM OF BUILDING All interactive system(s)points of interconnection with other AND ROOF sources shall be marked..." • Accessible location at disconnecting means, PHOTOVOLTAIC SYSTEM EQUIPPED as a power source: INVERTER OUTPUT CONNECTION WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN • Rated AC output current DO NOT RELOCATE THIS SWITCH TO THE"OFF" • Nominal operating AC voltage OVERCURRENT DEVICE POSITION TO SHUTDOWN PV SYSTEM AND SHOCK HAZERDINT REDUCE HEARRAY • '""`" PHOTOVOLTAIC AC DISCONNECT • ,..,.< RATED AC OUTPUT CURRENT: I NOMINAL OPERATING AC VOLTAGE: JOB NUMBER:1598 UTILITY:NG SC DE5Cft1 DESIGNED BY: — -SCHULMAN,JOSHUA SCHULMAN RESIDENCE MS P\/6 EM?C)WE.Z RACKINGIRONRIDGEXR-100 IU11LITYACCT#50732-97083 210 STATE ST 4.26 kW DC ROOF SOLAR SYSTEM s, sY:ENERGY SOLUTIONS MS MODULES:(12)LONG!LR4 60HPB355M NORTHAMPTON,MA.01060 3.80 kW AC REV: DAM INVERTER(1)SOLAREDGE INVERTER SE3800HUS(3.80 KW) (646)734-4616 asarmrz raoerwe: weans LING CONSULTING •- -- 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Coleman D. Larsen, SE, PE office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsu/ting.com October 6, 2022 Empower Energy Solutions 30 Old Kings Highway South #1001 Darien, CT 06820-4551 Re: Engineering Services Schulman Residence 210 State Street, Northampton MA 4.260 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing members for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: 2x6 Dimensional Lumber Framing members 24" on center. Roof Material: Tile Roofing Roof Slopes: 27 degrees Attic Access: Accessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 PSF • Live Load = 20 psf(reducible)—0 psf at locations of solar panels • Ground Snow Load = 40 psf • Wind Load based on ASCE 7-10 o Ultimate Wind Speed = 117 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2015 International Residential Code, including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110%for seismic elements. This analysis indicates that the existing framing members will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent Slate Plate installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a 5/16" lag screw is 235 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 2'/%", the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using one 5/16" diameter lag screw with a minimum of 21/2" embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48" on centers. 4. Panel supports connections shall be staggered to distribute load to adjacent framing members. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2015 IRC, current industry standards and practice, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. V truly your Scott E. Wyssli , PE MA License No. 505 OEm4S4�G rE / FSSioNm. Signed: 10/6/2022 WYSSLING CeNSiii TIN;;• LR4-60HPB Hi-Mo4m' 345~370M .., .. AAL1 (Black) f • _L... NEUv - • High__ Efficiency • ..`_�_ . - Low LID Mono PERC with Half-cut Technology - i i 1 1 j 12-year Warranty for Materials and Processing; / // \,\ 25 ear Warrantyfor Extra Linear Power Output.4.001010 -0 55 / It+ \ yO O , 4. 10% 98% t t 25-year Power \ r Addition Value Warranty Annual •, �i Additional from LONG,sot s`in Power Attenuation 91.2% t81.85% ar ear Warranty -0.55% /i' �, — t i i 87.7% ndardM�ulejmear 1+2.so/o ...'_ '// ' power—arrant), +3.35% u� 84.5% I'r 80.7% 1 5 10 15 20 25 Complete System and Product Certifications Positive power tolerance(0—+5W)guaranteed IEC 61215,IEC 61730,UL 61730 ISO 9001:2008:ISO Quality Management System High module conversion efficiency(up to 20.3%) ISO 14001:2004:ISO Environment Management System Slower power degradation enabled by Low LID Mono PERC technology:first yeari<2%, TS62941:Guideline for module design qualification and type approval 0.55%year 2-25 OHSAS 18001:2007 Occupational Health and Safety Solid PID resistance ensured by solar cell process optimization and careful modul BOM selection o , s�• C E c us Reduced resistive loss with lower operating current •Specifications subject to technical changes and tests. Higher energy yield with lower operating temperature LONGi Solar reserves the right of interpretation. Reduced hot spot risk with optimized electrical design and lower operating current ■ I..o r G Room 801,Tower 3,Lujiazui Financial Plaza,No.826 Century Avenue,Pudong Shanghai,2001 0,China Tel:+86-21-80162606 E-mail:module@longi-silicon.com Facebook:www.facebook.com/LONGi Solar Note:Due to continuous technical innovation,R&D and improvement,technical data above mentioned may be of modification accordingly.LONGi have the sole right to make such modification at anytime without further notice;Demanding party shall request for the latest datasheet for such as contract need,and make it a consisting and binding part of lawful documentation duly signed by both parties. 202 10V11 for US-D LR4-60H PB 345~370M Design(mm) Mechanical Parameters Operating Parameters 35 v )038 luul nuninnummriuuglmlm Cell Orientation:120(6x20) Operational Temperature:-40 C-+85 C mmmnnnnmmlmmm0mmt Junction Box:IP68,three diodes Power Ou Tolerance:0''+5W 111111111n1111111111nn1111111111M111 * « 9 11111111111111111111111111111111111111111 L 1 % < OutputCable:4mm',1200mm in length Voc and Ix Tolerance:±3% Illlllllllllllllllllllllllllnllllllllln m �3a _ � u11nl1111111111111111nllmhm1111111 V' 1111111111111111111111111111111111Illlnl Glass:Single glass Maximum System Voltage:DC100NJ(IEC/UL) IIIu1IlI I1111111i nmmmmminl nu1I1111111111nni1miil111n11I11111 3.2mm coated tempered glass Maximum Series Fuse Rating:20A mlIIIIminmll111mmlmminlm g _ IIIImn111111mu lllnnnnmlm111 C= a = 0 Frame:Anodized aluminum alloy frame Nominal Operating Cell Temperature:45±2 C mm11 munmlmumummumlu', Weight 19.5kg Safety Oats:lass u mIm 111111I11RE 111111111nmI111111 111111111111111111111111111111111111111111' 0 h wrnlaa) Dimension:1755x1038x35mm Fire Rating:ng:UL type 1 or 2 nlnnnlnnlnnnllulllmlminnn e • tee: IIIIIIIIIIIIIIIII1111IIIlltlmllll111111 II length±2mm Packaging:30pcs per pallet 111111111mnll111111WWI1111111Wm 997 « wmn.*Ain 'lmmllmllmunluummmlmm xegnt:tlmm 180pm per20'GP lmmwlwnmmlluummllunu _ -z PO-row time 780pcs per 40'HC Electrical Characteristics Test uncertainty for Pmax:±3% Model Number LR4-60HPB-345M LR4-60HPB-350M LR4-60HPB-355M LR4-60HPB-360M LR4-60HPB-365M LR4-60HPB-370M Testing Condition STC NOC1 STC NOCT STC NOCT STC NOCT STC NOCT ETC NOCT Maximum Power(Pmax/W) 345 257.6 350 261.4 355 265.1 360 268.8 365 272.6 370 276.3 Open Circuit Voltage(Voc/V) 40 2 37.7 40.4 3/.9 40.6 38.1 40.8 38.2 41.0 38.4 41.2 38.6 Short Circuit Current(lsc/A) 11.06 8.95 11.16 9.02 11.25 9.09 11.33 9.16 11.41 9.23 11.50 9.30 Voltage at Maximum Power(Vmp/V) 34.2 31.8 34.4 32.0 34.6 32.2 34.8 32.4 35.0 32.6 35.2 32.8 Current at Maximum Power(Imp/A) 10.09 8.09 10.18 . 8.16 10.27 + 8.23 10.35 8.30 10.43 8.36 10.52 8.43 Module Efficiency(%) 18.9 19.2 19.5 19.8 20.0 20,3 STC(Standard Testing Conditions):Irradiance 1000W/m2,Cell Temperature 25C,Spectra at AM1.5 1 NOCT(Nominal Operating Cell Temperature):Irradiance 800W/m2,Ambient Temperature 20 C,Spectra at AM1.5,Wind at 1m/S Temperature Ratings(STC) Mechanical Loading Temperature Coefficient of Inc +0.048%/C Front Side Maximum Static Loading 5400Pa Temperature Coefficient of Voc -0.270%/C Rear Side Maximum Static Loading 2400Pa Temperature Coefficient of Pmax -0.350%/C Hailstone Test 25mm Hailstone at the speed of 23m/s I-V Curve Current-Voltage Curve(LR4-60HPB-360M) Power-Voltage Curve(LR4-60HPB-360M) Current-Voltage Curve(LR4-60HP8-360M) 12 400 Celltemp•25e 12 Cell Tempw25(. 30 - 350 1000w/m' -1000w/m' 10 - Incident Irrid.•1000w/m' 300 -8004m' -600v/m' e00w/m' < g -Len Temp•25C j 250 -400w/m' Q g Cell Temp•35C -200w/m' -�,/m, 1 6 ' -Centempw5e 200 6 -Cell Temp+55 C 3 4 - -Cell Tempe65C 1so a 4 .pow/m' -cell Temp-75c 100 i .2 502 -Zoo«/m' 0 0 0 10 20 30 40 50 0 10 20 30 40 50 0 10 20 30 40 50 Voltage(v) Voltage(v) Voltage(v) II ISO N G I Room 801,Tower 3,Lujiazui Financial Plaza,No.826 Century Avenue,Pudong Shanghai,200120,China Tel:+86-21-80162606 E-mail:module@longi-silicon.com Facebook:www.facebook.com/LQNGi Solar Note:Due to continuous technical innovation,R&D and improvement,technical data above mentioned may be of modification accordingly.LONG'have the sole right to make such modification at anytime without further notice;Demanding party shall request for the latest datasheet for such as contract need,and make it a consisting and bindi'ig part of lawful documentation duly signed by both parties. 20200410V11 for US-D I Single Phase Inverter Single Phase Inverter z with HD-Wave Technology for North America g SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/ with HD-Wave Technology < SE7600H-US/SE10000H-US/SE11400H-US mMODEL NUMBER SE3000H-US SE3BOOH-US 5E5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US for North America APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4 SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/ 111 OUTPUT r 38000240v 00002V 14000240V SE7600H US/SE10000H US/SE11400H US Rated Output 3000 3300®2�V 5000 5000®208V 7600 10000 16060®208V A m Maximum AC Wier Output 3000 3800 0 240V SOOD 6000 0 240V 7600 10000 11403 O 240V VA 2-25 - - 3300 0208V 5000•208V 10000 0 208V ' 1 AC carom Voltage MA-Non.-rrlax. i i tic YEAR an-240-2641 o WARRANTY 1 AC Output Voltage rA n-Jonr-Max i - sr (1e3-20B-229) I AC Frequency(Nominal) 59.3-60-605 - - i Vac m He O 0 Madmum Continuous Output Current 0240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output - 16 - 24 - - 48.5 A Current 0208V O 0 Power Factor 1 Adjustable-0.85 to 0.85 O e GFt3 Threshold 1 A Utay Morrtorirg,Istan4rg Protection Yes Country Configurable Thresholds INPUT • solar .,,{-D... ® • solar-;,^^ .-.tom. O Maunum Pav er er 0240V 4650 5900 7750 I 9300 1 11800 15500 1 17650 W Maximum DC rawer 0208V 5100 I 7750 - - 15500 W - e 7. - - Transformer-less,Ungrounded 1bs O O Maximum Input 5eItage 480 Vdc O O .. Noeo6ral DC Input Voltage 380 400 tack Madmt a Mput Curr nt 0240Vm 8.5 10.5 135 165 20 27 30.5 Adc Madmen Input Current 0208V0 - 9 - 135 - - 27 Adc Max.Input Shot Circuit Current 45 Adc es O 0 Reverse-Polarity ProtectionCr `4s IF _ 0118 1laiiid Ground-Fault Isolation Detection Sensitivity Madmum Inverter Efficiency 99 I 992 % CEC Weighted Efficiency 99 99 0 240V % 98.5 0 203V Nghtenre Poser Consumption <2.5 W Optimized installation with HD-Wave technology ameer,e9;eal=rmnorpleawcontortSol,Ed,espport u A 1010,current souse we be used me 6uerb+i ire Os inpa novo to the values anted I Specifically designed to work with power optimizers / UL1741 SA certified,for CPUC Rule 21 grid compliance / Record-breaking 99%weighted efficiency / Small,lightweight,and easy to install both outdoors or indoors / Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp / Built-in module-level monitoring / Fixed voltage inverter for longer strings / Optional:Faster installations with built-in consumption metering(1%accuracy)and production revenue grade / Integrated arc fault protection and rapid metering(0.5%accuracy,ANSI C12.20) shutdown for NEC 2014 and 2017,per article 690.11 and 690.12 - - solaredge.com Solar " se : Single Phase Inverter With HD-Wave Technology for North America SE3000H-US/ SE3800H-US/SE5000H-US/SE6000H-US/ SE7600H-US/ SE10000H-US/SE11400H-US MODEL NUMBER SE3000H-US SE3800H-US SES000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Canmunkatbn Interfaces R5466,Ethernet ZlgBee(optimal),CelloW(optlo0,8 Revenue Grade Metering,ANSI C1220 opeona0° Consumption metering ._...._.. Inverter Commissioning With the SetApp mobile application using Suit-in Wi-Fl Access Point for Loral Correction Rapid Shutdown-NEC 2014 and Automatic Rapid Shutdown upon AC Grid Dismrxrec 2017 690.12 STANDARD COMPLIANCE Safety U1.1741,UL1741 SA,UL1699B,CSA C77 2 Casadan AFO acmr3g to TEL.14-07 Grid Convection Standards IEEE1547,Rule 21.Rule 14(H0 Emissions FCC Part 15 Class 8 INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG 1'Maxirxtm/14-6 AWG 1"Maximum/14-4 AWG Range DC input Conduit Size/t of Soisrgs/ 1"Marirtxam/1-2 abtgs/14-6AWG 1"Maximum/1-3 Brigs/14-6 AWG AWG Range Dimensions with SafetySwitch 17.7 x14.6 68/450x370xi74 2U x14.6x7.3/540x 370 it1BS mm Weighs with Safety Switch 22/10 1 25.1/11.4 J 262/11.9 38.8/17.6 Ib/kg Noise <25 I <50 dBA Coding Natural Convection Operating Temperature Range -40 to+140/-40 to.60' 'F Protection Rating NEMA 4%(Inverter oath Safety Switc) m Inverse-with Revenue Grade Meter PM SFsmo 4-U500®NCh,inserter with Renew:Grade Production and Consumption Meter P/N.SEooull-U1 lNLC.For mr•xryam netMy currentbandmrrlxn shade be ordered separately SFAC1075620011A-20u SFKT0751H00N4-20.20 ones per bu ot h4 Pan w a a kas SOY/122'F fir porter de atrg Iraormalion refer to NWArwwodsmge.cwT4re✓de+ads/tkr/se-temperaum-demengnae-m.pu How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel,homeowners will gain full insight into their household energy usage helping them to avoid high electricity bilk Single phase-in Rter with HD-wave technology and built-in GM and Sr[!IV10G Panelconsumption monitoring • GM0 I CT L1 N l2 Slittded C/OSe cable i LI 12 • gi AC Corti °b� ,.`°n,owl N. �, ..s.0. Daft 01�r/ uuaeSOLerS me lartsaeoew+rmdwWal5oWr4L4sb9uYCM RoH3 awte.,.,s mre. Power Optimizer p For North America P370 / P400 / P401 / P485 / P505 m 71:3 25 0 YEAR WARRANTY PV power optimization at the module-level / Specifically designed to work with SolarEdge / Fast installation with a single bolt inverters / Next generation maintenance with module- / Up to 25% more energy level monitoring / Superior efficiency(99.5%) / Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid / Mitigates all types of module mismatch losses, Shutdown System (PVRSS) from manufacturing tolerance to partial shading / Module-level voltage shutdown for installer and firefighter safety / Flexible system design for maximum space utilization solaredge.com solar • • Power Optimizer For North America P370 / P400 / P401 / P485 / P505 Optimizer model P370 P400 P401 P485 P505 (typical module compatibility) (for higher-power 60 (for 72 &96- (for high power 60 (for high-voltage (for higher and 72-cell modules) cell modules) and 72 cell modules) modules) current modules) INPUT Rated Input DC Powerm 370 400 485 505 W Absolute Maximum Input Voltage 60 80 60 1250 830 Vdc (trot at lowest temperature) , MPPT Operating Range 8-60 8-80 8-60 12.5-105 12.5-d3 vdc Maximum Short Circuit Current(Isc) 11 10.1 11.75 11 14 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 80 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1±01 Vdc STANDARD COMPLIANCE Photovoltaic Rapid Shutdown System NEC 2014,2017&2020 NEC 2014,2017&2020 NEC 2014,20 7&2020 EMC FCC Part 15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),U11741 Material UL94 V-0,UV Resistant RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions(WxLxH) 129x153x27.5/5.1x6 129x153x33.5/ 129x153x29.5/5.1x6 129x153x33.5/5.1 129x162x59/ mm x 1.1 5.1 x 6 x 1.3 x 1.16 x6x1.3 5.1x6.4x2.3 /in Weight(including cables) 655/1.4 750/1.7 655/1.4 845/1.9 1064/2.3 gr/lb Input Connector MC4(31 Single or dual MC4010 MC401 Input Wire Length 0.16/0.52,0.9/2.9501 0.16/0.52 0.16/0.52,0.9/2.95w 0.16/0.52 0.16/0.52 m/ft Output Wire Type/Connector Double Insulated/MC4 Output Wire Length 1.2/3.9 m/ft Operating Temperature Rangem -40 to+85/-40 to+185 'C/'F Protection Rating IP68/NEMA6P Relative Humidity 0-100 % (1)Rated power of the module at STC will not exceed the optimizer"Rated Input DC Power'.Modules with up to+5%power tolerance are allowed (2)NEC 2017 requires max input voltage be not more than 80V (3) For other connector types please contact SolarEdge (4)For dual version for parallel connection of two modules use P485-4NMDMRM.In the case of an odd number of PV modules in one string,instating one P485 dual version power optimizer connected to one PV module.When connecting a single module seal the unused input connectors with the supplied pair of seals (5)For ambient temperature above+85'C/+185'F power de-rating is applied.Refer to Power Optimizers Temperature De-Rating Technical Note for more details PV System Design Using a SolarEdge Single Phase Three Phase for Three Phase for Invtorter HD-Wave Single phase 208V grid 277/480V grid Minimum String Length P370,P400,P401 8 10 18 (Power Optimizers) P485,P505 6 8 14 Maximum String Length(Power Optimizers) 25 25 50 Maximum Nominal Power per String 5700"(6000 with 52500 6000'. 12750''' W SE7600-US-SE11400-US) Parallel Strings of Different Lengths or Orientations Yes _ (6) For detailed string sizing information refer to:http://wnnvsolaredge.com/sites/default/files/sMng.sizing_na.pdf (7) It is not allowed to mix P485/P505 with P370/P400/P401 in one string (8)If the inverters rated AC power s maximum nominal power per string,then the maximum power per string will be able to reach up to the inverters maximum input DC power.Refer to:https://www..solaredge. con/sttes/default/files/se-poweroptimizer-single-string-design-application-note.pdf (9)For 208V grid:It is allowed to install up to 7,200W per string when the maximum power difference between each string Is 1,000W (10)For 277/480V grid:it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W 0 SolarEdge Technologies Ltd.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE ere trademarks or registered trademarks of SolarEdge Technologies, cC-n^I,ua Ro H 3 Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:04/2021 DS-000044.0.0-NA.Subject to change without notice. Intertek Tech Brief Tech Brief 4 IRONRIDGE XR Rail Family XR Rail Family The XR Rail Family offers the strength of a c:.ed rail in three targeted sizes.Each size supports specific design loads,while minimizing material costsepending on your location,there is an XR Rail to match. Solar Is Not Always Sunny ,r , Over their lifetime,solar panels experience countless •. extreme weather events.Not just the worst storms in years, " but the worst storms in 40 years.High winds capable of - - ete, - -. . ripping panels from a roof,and snowfalls weighing Iii_ . , "' enough to buckle a panel frame. ! - r , _ `......,,,..... t....„,,,_ XR Rails are the structural backbone preventing { l - these results.They resist uplift,protect } - XR10 XR100 XR1000 against buckling and safely and efficiently i ' y' a . : XR10 is a sleek.low-profile mounting XP1lX1 is the It ate residential XR1000 re a heavyweight among transfer loads into the building structure. µ / ,� ; I designed for regions with rplaa mounting rat_I1 ports a range d solar mounting rails.Its wan to handle Their superior spanning capability d* * -- no snow It achieves spans up to 6 Nair, 0d and.snow condemns.whde also extreme cinates and spans up to 12 requires fewer root attachments, '. while remaining light and econorrecal. maximizing spans up to 10 feet teat for commercial appicatiom reducing the number of roof • * , . • 6 spanning capability • 10 spanning capability • 12 spanning capabikty penetrations and the amount .y`'.; y • Moderate Iced capability • Heavy load capability • Extreme load capability • Clear&black anodized brash • pear&black anodized finish • Clear anodized finish of installation time. `. ,.. '. ' • Internal splices available • Internal splices evadable • Internal splices available } Rail Selection s,- The table below was prepared in compliance with applicable engineering codes and standards.'Values are based on the following criteria:ASCE 7-16,Gable Roof Flush Mount,Roof Zones 1&2e,Exposure B,Roof f�," Slope of B to 20 degrees and Mean Building Height of 30 ft.Visit IronRidge.com for detailed certification letters. Load Rail Span Snow(P.SFI•Wind(MPH) 4' S'4" 5 a 10 12' `�`���" z` $s y ForceSYabiizing Curve � , >^K• e �, ,. Sloped roofs generate both vertical and lateral . 120 s3„ -"' ` forces n mounting rails which can cause them Z:S `"'1t•. None 05 t to bend and twist The ad shape of XR Raab 140 XAIO ' r M^ 's specially dawned r increase strength at both 1� 5� d Directions while resisting the twisting.This unique p�y�'jr�,,rc,:� 1 ` t feature ensures greater seouMy during extreme 160 e�i akah ? weather and a longer system lifetime. 90 '� i 120 i j 20 140 tee 31.Z. 90 .s tee Ilk Compatible with Flat&Pitched Roofs Corrosion-Reaiat nt Materials :: 120 %R Rails arerl IrnRidge peers N XR Reis are made d dW0•aeries r. .y, '� 3� compatible with �•�,r rge of tM leg aluminum alloy.then protected with an 160 1. € tx otller obi tiro I optons for flat anodized finish.Anodizing prevents surface _.od 1 t tool punting and slnx:tunei cortosion,wtliN aloe prOvidlr1.______.....1 BD 1� f attachments. applications a more attractive appearance. ' 'rgYa meantIo be a WINNOW span cleat for nerseyerg bane tat,apabaitres..be approved cereficawn Isaac tar aduatdeelgn 9Wrx:e. _ _ - _ _- rJP2aIronar]9.,ice.Agright.+•eaervatl.Y.sneon,.rerrtCye.cmt'r.eIn.aao.zz. 0,31certwmInlom,a•ian.Waskw*.2u ,/r'