Loading...
05-049 (12) BP-' 022-1320 623 KENNEDY RD COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 05-049-001 CITY OF NORTHAMPTON Permit: Solid Fuel Appliance PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2022-1320 PERMISSION IS HEREBY GRANT D TO: Project# PELLET STOVE Contractor: License: Est. Cost: DOUGLAS L'ABBEE CSL99401 Const.Class: Exp.Date: 01/06/2024 Use Group: Owner: MANGIAMELE EASTWOOD BRIAN S&LISA A Lot Size (sq.ft.) Zoning: WSP Applicant: THE FIRE PLACE Applicant Address Phone: Insurance: 100 STATE RD (413)397-3463 01400503301116 WHATLEY, MA 01093 ISSUED ON: 10/13/2022 TO PERFORM THE FOLLOWING WORK: PELLET STOVE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House-# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIO ATION OF ANY OF ITS RULES AND REGULATIONS. Signature: (Pi (Y� Fees Paid: $40.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Office of the Building Commissioner 71J\ City of Northampton" � tH MYTH Massachusetts 1 f 4- : \moo oT `cam �,` * c` 9�P J y ( ,.T, ' DEPARTMENT OF BUILDING INSPEC t'�-"= (� 7e 212 Main Street • Municipal Buil• '3 SS ^a r \` .,+...� Northampton, MA 01060 OyG� � �ssy`t�'��tQ "4 To i' 1 -9 �o%Js APPLICATION FOR SOLID FUEL APPLIANCE INSTALLATION Property Information Owners Name: / 'r/t n EAST t(70(0 Address: 6,23 A'nnccxl /o /-cry S INA aiet,53 (No.) (Street Address) Phone: 41i3. 570- /93 C 11: Email: Owners Signature: Date: ti'V Contractor's Information (If Applicable) Name: % eoyls L 79hhcc_ Phone: Y/3 .37t 5-c(C 3 Construction Supervisor's License #: 9'PV(1/ Expiration: /-6-•7 V Home Impr. Contractor License #: /Fos/77 Expiration: //-ip, Stove Information Type of Fuel (check all that apply): Wood Pellet Coat Location: 'T //oo,- (,--_.2„s4_„v r,).-') Freestanding InsOrt Manufacturer: A/erap^ Model: -7513 '"3 7/`i/'^9 4 f il d/,.r, o ---_---------------FOR BUILDING DEPARTMENT USE ONLY--------------------------- Permit# 60- aa-f.3a0 Date Applied: • Total all Fees: $ T 0 CO t36 3 Building Official: /4-v eA .,.__ 1 ? s Date Issued: 10-/3 ZO2 2 (P t) ///0 Signature of Building Official: A/se. a.vriii/c vri rvowiori VJ SrAiiJ.Yio\./LLLJGOOJ n-=' Department of Industrial Accidents Office of Investigations s I1Yr-:.t',. � Lafayette City Center =: 2 Avenue tie Lafayette, Boston,MA 02111-1750 '.`"*A..`.`' • MM.Mass. ov/dia Workers' Compensation insurance Affidavit: Builders/Contractors/.Electricians/Plumbers iapplicant Information Please Print Legibly game (Business/Organization/individual):THE FIRE PLACE kddress:100 STATE ROAD L'ity/State/Zip:WHATELY, MA 01093 Phone#:413-397-3463 y re you an employer'? Check the appropriate box: Type of project(required): gii I am a employer with 10 4. ❑ I am a general contractor and I employees (full and/or part-time).* have hired the sub-contractors 6. ❑Neer construction ❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑Remodeling ship and have no employees These sub-contractors have g. ❑ Demolition working for me in any capacity. employees and have workers' 9. ❑ Building addition [No workers' comp.insurance comp. insurance.t ❑ We are a corpo ration�. and its 10.0 Electrical repairs or additions _ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. fNo workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.] '' c. 152,§1(4),and we have no employees. No workers' 13.❑ Other comp. insurance required.] 1 ty applicant that checks box#l must also fill out the section below showing their workers'compensation policy information. omeowners who submit this affidavit indicating they arc doing all work and then hire outside contractors must submit a new affidavit indicating such. nttractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have tloyees. If the sub-contractors have employees,they must provide their workers'comp.policy number. nr art employer that is providing workers'compensation insurance for my employees. Below is the policy and job site i rination. nuance Company Name:MA RETAIL MERCHANTS WC GROUP INC liey#or Self ins.Lic.#:01400503301116 Expiration Date:1-1-23 �-3, / 7/1e0y ~ � City/State/Zip: L��DS ,�� . I b Site Address: G !a/6`S3 :tack a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). ilure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a le up to S 1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a tine up to S250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of vestigations of the DIA for insurance coverage verification. io hereby c•er•tfivurd,r•the pains any pL'Jr ies of perjury that the information provided above is true and correct. gnature: ,. _ d Dttte: /6' 3 Torte 4: 413-397-3463 . Official use only. Do not write in this area,to he completed by city OP town official. City or Town: Permit/License# Issuing Authority(check one): 10Board of Health 20 Building Department 3fCity/Town Clerk 4.❑Electrical Inspector 51=1Plumbing Inspector 6.0Other Contact Person: Phone#: 3 Clearances A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. P43-C Freestanding Pellet Stove P61-C Freestanding Pellet Stove .,.....w. � I .?. Mom. Autside Outside Air Intake = Air IntakeIi1 IMip 51/8' 51/8' 22' O O 231/2" - ,FA To I I ._ O zo- O N m CO "...N....3 3 ry Ill b I ‘7411.1 3/4" I I I .) J P68-C Freestanding Pellet Stove i. IMP ' Outside Air Intakes i M �V4V/� szr IIIi I 5 1/4'- - —23-1/2' e e v v vvvvv �� rn.. ? _ O M 4 .11 l ._._. . . . . N . . I f 1 t ' I I Figure 3.1 8 Harman® • P-Series Installation Manual_R4 • 2018- • 04/21 8390-0441 B. Clearances to Combustibles Place the stove away from combustible walls at least as far When selecting a location for the appliance it is important to as shown in Figure 3.2. Please note the difference in side consider the required clearances to walls, Figure 3.2. wall clearance with and without side shields. Note that the clearances shown are minimum for safety but do A WARNING not leave much room for access when cleaning or servicing. Please take this into account when placing the stove. RISK OF FIRE OR BURNS! Provide adequate Due to high temperatures,the stove should be placed out of clearance around air openings and for service traffic and away from furniture and draperies. access. Due to high temperatures, the appliance should Children and adults should be alerted to the hazards of high be located out of traffic and away from furniture and surface temperatures and should stay away to avoid burns draperies. to skin and/or clothing. Young children should be carefully supervised when they are ACAUTION in the same room as the stove. Clothing and other flammable materials should not be placed THIS APPLIANCE MUST BE VENTED TO THE OUTSIDE. on or near this unit. NOTICE:Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY.Actual installation may vary due to individual design preference. P61-C & P68-C Freestanding Pellet Stove P43-C Freestanding Pellet Stove 14"(355mm)with 2"(51mm) 2"(51mm)[ ` , '10"(254mm)with ` side shields 0 ♦ side shields /I , ', 20"(508mm) '16"(406mm) without side shieldsbilelmotro14"(355mm) without side shields o '10"(254mm) 20"(508mm) '16"(406mm) 11/ 36"(914mm) 36"(914mm) 9"(228mm)- 9"(228mm) 13"(330mm) o i ,+ cp II 9"(228mm)With Side Shields 13"(330mm) Without Side Shields 9"(228mm) With or Without Side Shields Figure 3.2 9 Harman® • P-Series Installation Manual_R4 • 2018- • 04/21 8390-0441 C. Floor Protection Corner Installation: Parallel Installation: Minimum size floor protection for a corner installation hearth pad is: Place the stove on a noncombustible type floor or floor P43-C - Minimum size floor protection is 25-7/16" Wide by protector that extends a minimum of 6 inches (152mm) to 26-3/4" Deep (646mm X 680mm). the front of the load door opening, 6 inches (152mm)to the sides of the door opening, and 6 inches to the rear. P61-C - Minimum size floor protection is 25-1/8" Wide by The P-Series does not require R value floor protection. 27-3/4" Deep (638mm X 705mm). The minimum floor protector material is 20 gauge sheet metal. P68-C - Minimum size floor protection is 25-3/16" Wide by Other floor protector materials that can be used include Type 27-3/4" Deep (640mm X 705mm). I hearth pads, ceramic tile, stone, brick, etc. Figure 3.3 Note: Floor protector WILL NOT touch the wall using "Floor protection dimensions for the front and sides are minimum clearances. measured from the appliance door opening in The United If corner floor protection is desired to touch the wall, the States. In Canada,the side dimension is measured from the floor protection will need to be at least 40" x 40" (1016mm widest part of the appliance. x 1016mm). Note: This will allow the floor protection to P43-C - Minimum size rectangular floor protection is 25- touch the wall as shown. Figure 3.4. 7/16"Wide by 26-3/4" Deep (646mm X 680mm). Alternate floor protector dimension may be used as long as P61-C-Minimum size rectangular floor protection is 25-1/8" they satisfy the measurement requirements shown below. Wide by 27-3/4" Deep (638mm X 705mm). P68-C - Minimum size rectangular floor protection is 25- 3/16"Wide by 27-3/4" Deep (640mm X 705mm). Venting: UPS-Follow PL vent manufacturers recommendations when configuring vent pipe installation. Canada- Must extend 2" (51mm) beyond each side of any horizontal flue pipe. eig 0 .1111 Figure 3.4 D. Mobile Home Installation When installing this unit in a mobile Home, several i1111111- requirements must be followed: J Floor Protector 1. The unit must be bolted to the floor. This can be done K using an appropriate fastener for the aplication. Figure 3.3 2. The unit must also be connected to .outside air. See "Termination Location and Vent Information" Section D. Floor Protection US Canada 3. Floor protection and clearances must be followed as Requirements shown. J Sides 6" 152mm 4. The appliance must be properly grounded to the frame of K Front 6" 152mm the mobile home using a minimum of 8 AWG copper solid L Rear 6" 152mm or stranded, insulated or bare wire or equivalent. 10 Harman® • P-Series Installation Manual_R4 • 2018- • 04/21 8390-0441 4 Termination Location and Vent Information A. Vent Termination Minimum Clearances Note: Follow venting manufacturer's recommendations for sealing pipe joints. #1 Preferred method (Figure 4.1) This method provides excellent venting for normal operation and allows the stove to be installed closest to the wall.Two inches from the wall is safe; however, four inches allows better access to remove the rear panel.The vertical portion of the vent should be three to five feet high.This!vertical section will help provide natural draft in the event of a power failure. Do not place joints within wall pass-through. 3Ft. to Combustibles 44 6 71/4.de 3 Ft. to Combustibles Figure 4.1 #2 Preferred method(Figure 4.2) This method also provides excellent venting for normal operation but requires the stove to be installed farther from the wall. The vertical portion of the vent should be three to five feet high and at least 1" from a combustible wall. This vertical section will provide natural draft in the event of a power failure. If the stove is installed below grade be sure the vent termination is at least 12"above grade. The outlet must also — � be 1 foot from the house/building. /��" 3tot' Do not place joints within wall pass-through. Combustibles A CAUTION • Keep combustible materials (such as grass, leaves, etc.) at least 3 feet away from the flue outlet on the outside of the building. a � IIC� HI3 Ft. to Combustibles Figure 4.2 11 Harman® • P-Series Installation Manual_R4 • 2018- • 04/21 8390-0441