4SHM073A_A and E_CDs_Anchor_CD Rev2_08182022PROJECT INFORMATION
PROJECT DIRECTORY
Know what's below.
Call before you dig.
R
GENERAL NOTES
THESE DRAWINGS ARE FORMATTED TO BE FULL SIZE AT 22"x34". CONTRACTOR
SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON THE JOB
SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY
DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE
FOR SAME.
DRAWING SCALE NOTES:
N
PROJECT
LOCATIONPROJECT
LOCATION
SITE NAME:
SITE NUMBER:
SITE ADDRESS:
COUNTY
MUNICIPALITY:
ZONING:
LATITUDE:
LONGITUDE:
TYPE OF SITE:
STRUCTURE HEIGHT:
ANTENNA CENTER:
GROUND ELEVATION:
BUILDING OWNER NAME:
BUILDING OWNER
ADDRESS:
APPLICANT:
APPLICANT PHONE:
APPLICANT FAX:
SITE NAME: COOLEY HOSPITAL RT
SITE ID: 4SHM073A
ADDRESS: 30 LOCUST ST
NORTHAMPTON, MA 01060
TECHNOLOGY: 67E05A
MODIFICATION: L600_PHASE 3
SCOPE OF WORK
COOLEY HOSPITAL RT
4SHM073A
30 LOCUST ST
NORTHAMPTON, MA 01060
HAMPSHIRE COUNTY
CITY OF NORTHAMPTON
M(99)/WP(21)/URB(1)
N 42°23'5700" (42.33089828°) (NAD83)
W 72°01'51.00" (-72.65432740°) (NAD83)
ROOFTOP
67'-0" AGL
73'-0" AGL
228'-0" (NAVD 88)
COOLEY DICKINSON HOSPITAL INC
30 LOCUST STREET
NORTHAMPTON, MA 01060
ENGINEERING FIRM:
CENTERLINE ENGINEERING SERVICES
750 WEST CENTER ST, SUITE 301
WEST BRIDGEWATER, MA 02379
DEREK CREASER (617) 306-3034
NO.DESCRIPTION
DRAWING INDEX
SITE NAME:
SITE ID:
SITE ADDRESS:
SHEET TITLE:
DRAWING:
4SHM073A
COOLEY HOSPITAL RT
30 LOCUST ST
NORTHAMPTON, MA 01060
HAMPSHIRE COUNTY
COUNTY
T-1
DATE: 08/18/2022
IT IS A VIOLATION OF LAW FOR ANY PERSON UNLESS THEY ARE ACTING UNDER THE
DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT.
UNLESS EXPLICITLY AGREED TO BY THE ENGINEER IN WRITING, THE ENGINEER
DISCLAIMS ALL LIABILITY ASSOCIATED WITH THE REUSE, ALTERATION OR
MODIFICATION OF THE CONTENTS HEREIN.
T-MOBILE NORTHEAST, LLC.
15 COMMERCE WAY, SUITE B
NORTON, MA 02766
PHONE: (508) 286-2700
FAX: (508) 286-2893
- MobileT
NORTHEAST LLC
750 W CENTER ST, SUITE 301
WEST BRIDGEWATER, MA 02379
PHONE: 781.713.4725
ENGINEERING SERVICES, PA
TITLE SHEET
CARRIER:
T-MOBILE NORTHEAST, LLC.
15 COMMERCE WAY, SUITE B
NORTON, MA 02766
PHONE: (508) 286-2700
FAX: (508) 286-2893
T-MOBILE NORTHEAST, LLC.
15 COMMERCE WAY, SUITE B
NORTON, MASSACHUSETTS 02766
(508)286-2700
(508)286-2893
- MobileT
NORTHEAST LLC
ENGINEERING SERVICES, PA
SITE NAME:
SITE ID:
SITE ADDRESS:
SHEET TITLE:
DRAWING:
4SHM073A
COOLEY HOSPITAL RT
30 LOCUST ST
NORTHAMPTON, MA 01060
HAMPSHIRE COUNTY
COUNTY
GN-1
DATE: 08/18/2022
IT IS A VIOLATION OF LAW FOR ANY PERSON UNLESS THEY ARE ACTING UNDER THE
DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT.
UNLESS EXPLICITLY AGREED TO BY THE ENGINEER IN WRITING, THE ENGINEER
DISCLAIMS ALL LIABILITY ASSOCIATED WITH THE REUSE, ALTERATION OR
MODIFICATION OF THE CONTENTS HEREIN.
T-MOBILE NORTHEAST, LLC.
15 COMMERCE WAY, SUITE B
NORTON, MA 02766
PHONE: (508) 286-2700
FAX: (508) 286-2893
- MobileT
NORTHEAST LLC
750 W CENTER ST, SUITE 301
WEST BRIDGEWATER, MA 02379
PHONE: 781.713.4725
ENGINEERING SERVICES, PA
RF NOTES
ABBREVIATIONS
EQUIPMENT GROUND
EQUIPMENT GROUND RING
AMERICAN WIRE GAUGE MASTER GROUND BUS
REF
N.T.S.
RADIO FREQUENCY
TO BE REMOVED
REFERENCE
NOT TO SCALE
REQ
TYP TYPICAL
REQUIRED
RF
TBR
BARE COPPER WIRE
PROPOSED NEW
EGR
AWG MGB
EG
BCW
AGL ABOVE GRADE LEVEL
BTS BASE TRANSCEIVER STATION
EXISTING EXISTING
MIN MINIMUM TBD TO BE DETERMINED
G.C.GENERAL CONTRACTOR
TO BE REMOVEDTBRR
AND REPLACED
1.ACTUAL LENGTHS SHALL BE DETERMINED PER SITE CONDITION BY
SUBCONTRACTOR
2.THE DESIGN IS BASED ON RF DATA SHEETS, SIGNED AND APPROVED.
3.RADIO SIGNAL CABLE AND RACEWAY SHALL COMPLY WITH THE
REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE (NEC, NFPA 70),
CHAPTER 8.
4.ALL SPECIFIED MATERIAL FOR EACH LOCATION (E.G. OUT DOORS-OCCUPIED,
INDOORS-UNOCCUPIED, PLENUMS, RISER SHAFTS, ETC.) SHALL BE
APPROVED, LISTED, OR LABELED AS REQUIRED BY THE NEC.
5.RADIO SIGNAL CABLE SHALL BE SUPPORTED AT MINIMUM OF EVERY THREE (3)
FEET EXCEPT INSIDE MONOPOLES OR MONOPOLES WHERE CABLE AND
CONNECTOR MANUFACTURERS SUPPORT RECOMMENDATIONS SHALL BE
FOLLOWED. MANUFACTURER RECOMMENDATION CABLES SUPPORT
ACCESSORIES SHALL BE USED.
6.THE OUTDOOR CABLE SUPPORT SYSTEM SHALL BE PROVIDED WITH AN ICE
SHIELD TO SUPPORT AND PROTECT ANTENNA CABLE RUNS.
7.DRIP LOOPS SHALL BE REQUIRED ON ALL OUTSIDE CABLES. CABLES SHALL
BE SLOPED AWAY FROM BUILDING OR OUTDOOR BTS CABINETS TO PREVENT
WATER FROM ENTERING THROUGH THE COAXIAL CABLE PORT.
8.ALL FEEDER LINE AND JUMPER CONNECTORS SHALL BE 7/16 DIN CABLE
CONNECTORS THAT MEET IP68 STANDARDS.
9.7/16 DIN CONNECTORS REQUIRE NO ADDITIONAL WEATHER PROOFING IN
INDOOR APPLICATIONS IF INSTALLED AND TORQUED PROPERLY. IN OUTDOOR
APPLICATIONS WEATHER PROOFING IS REQUIRED AND THE FOLLOWING
PROCEDURE SHOULD BE FOLLOWED.
10.USING WEATHERPROOFING KIT APPROVED BY CABLE MANUFACTURER AND
CONTRACTOR START TAPE APPROXIMATELY 5 INCHES FROM THE
CONNECTOR, AND WRAP 2 INCHES TOWARD THE CONNECTOR, THEN
REVERSE THE TAPE SO THAT THE STICKY SIDE IS UP. TAPE OVER THE
CONNECTOR OR SURGE ARRESTOR UNTIL THREE (3) TO FOUR (4) INCHES
BEYOND THE CONNECTOR AND REVERSE AGAIN WITH THE STICKY SIDE DOWN
FOR ANOTHER INCH OR TWO. PASS THE BUTYL RUBBER AND FINISH WITH A
FINAL LAYER OF TAPE.
11.ANTENNAS SHALL BE PAINTED,WHEN REQUIRED, BY THE LANDLORD OR
AUTHORITY OF HAVING JURISDICTION IN ACCORDANCE WITH ANTENNA
MANUFACTURERS' SURFACES PREPARATION AND PAINTING REQUIREMENTS.
12.CABLE SHIELDS AND TOWER CONDUITS SHALL BE GROUNDED AT THE TOP OF
THE TOWER WITHIN 10 FEET OF THEIR CONNECTORS, AND AT THE BOTTOM
OF THE TOWER ABOUT 6 INCHES BEFORE THEY TURN TOWARD THE FACILITY.
THEY SHALL BE GROUNDED AT THE MIDPOINT OF THE TOWERS THAT ARE
BETWEEN 60 FEET AND 200 FEET HIGH, AND AT INTERVALS OF 60 FEET OR
LESS ON TOWERS THAT ARE HIGHER THAN 200 FEET.
1.SUBCONTRACTOR SHALL VERIFY THE ACTUAL LENGTH IN THE FIELD BEFORE
INSTALLATION.
2.TAG AND COLOR CODE ALL MAIN CABLES AT LOCATIONS PER T-MOBILE
ANTENNA CABLE MARKING STANDARD:
·TOP OF TOWER END OF MAIN COAX
·BOTTOM OF TOWER END OF MAIN COAX
·DIRECTLY BEFORE AND AFTER RF EQUIPMENT
·END OF JUMPERS AT BTS EQUIPMENT
3.ANTENNAS SHALL BE PROCURED AND INSTALLED WITH DOWN TILT MOUNTING
BRACKETS SUPPLIED BY ANTENNA MANUFACTURER.
4.PRIOR APPROVAL IS REQUIRED BEFORE PERFORMING ANY WORK ON EXISTING
CELL SITE EQUIPMENT.
1. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING
DEFINITIONS SHALL APPLY:
CONTRACTOR - CENTERLINE COMMUNICATIONS
SUBCONTRACTOR - GENERAL CONTRACTOR (CONSTRUCTION)
OWNER - T-MOBILE MOBILITY
2. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING SUBCONTRACTOR
SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS
AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON
THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE
BROUGHT TO THE ATTENTION OF CONTRACTOR.
3. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT
ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND
ORDINANCES. SUBCONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES
AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND
LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE
PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH
ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND
LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE
REGULATIONS.
4. DRAWINGS PROVIDED HERE ARE NOT TO BE SCALED AND ARE INTENDED
TO SHOW OUTLINE ONLY.
5. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING
MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO
COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS.
6. "KITTING LIST" SUPPLIED WITH THE BID PACKAGE IDENTIFIES ITEMS THAT
WILL BE SUPPLIED BY CONTRACTOR. ITEMS NOT INCLUDED IN THE BILL OF
MATERIALS AND KITTING LIST SHALL BE SUPPLIED BY THE SUBCONTRACTOR.
7. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN
ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS
SPECIFICALLY STATED OTHERWISE.
8. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON
THESE DRAWINGS, THE SUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE
INSTALLATION SPACE FOR APPROVAL BY THE CONTRACTOR.
9. SUBCONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT,
POWER AND T1 CABLES, GROUNDING CABLES AS SHOWN ON THE POWER,
GROUNDING AND TELCO PLAN DRAWING. SUBCONTRACTOR SHALL UTILIZE
EXISTING TRAYS AND/OR SHALL ADD NEW TRAYS AS NECESSARY.
SUBCONTRACTOR SHALL CONFIRM THE ACTUAL ROUTING WITH THE
CONTRACTOR.
10. THE SUBCONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS,
PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART
SHALL BE REPAIRED AT SUBCONTRACTOR'S EXPENSE TO THE SATISFACTION
OF OWNER.
11. SUBCONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL
SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED
FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED
TO THE OWNER'S DESIGNATED LOCATION.
12. SUBCONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION.
13. ALL CONCRETE REPAIR WORK SHALL BE DONE IN ACCORDANCE WITH
AMERICAN CONCRETE INSTITUTE (ACI) 301.
14. ANY NEW CONCRETE NEEDED FOR THE CONSTRUCTION SHALL BE
AIR-ENTRAINED AND SHALL HAVE 4000 PSI STRENGTH AT 28 DAYS. ALL
CONCRETE WORK SHALL BE DONE IN ACCORDANCE WITH ACI 318 CODE
REQUIREMENTS.
GENERAL NOTESANTENNA CABLE &
SCHEDULING NOTES
BUILDING CODE: IBC 2015 & MA STATE BUILDING 780 CMR 9TH EDITION
ELECTRICAL CODE: 2020 NATIONAL ELECTRICAL CODE
LIGHTNING CODE: NFPA 780-2020
15. ALL STRUCTURAL STEEL WORK SHALL BE DETAILED, FABRICATED AND
ERECTED IN ACCORDANCE WITH AISC SPECIFICATIONS. ALL STRUCTURAL
STEEL SHALL BE ASTM A36 (Fy = 36 ksi) UNLESS OTHERWISE NOTED. PIPES
SHALL BE ASTM A53 TYPE E (Fy = 36 ksi). ALL STEEL EXPOSED TO WEATHER
SHALL BE HOT DIPPED GALVANIZED. TOUCHUP ALL SCRATCHES AND OTHER
MARKS IN THE FIELD AFTER STEEL IS ERECTED USING A COMPATIBLE ZINC
RICH PAINT.
16. CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND "GENERAL
CONSTRUCTION SERVICES FOR CONSTRUCTION OF T-MOBILE MOBILITY
SITES."
17. SUBCONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND
CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF
EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS MUST BE VERIFIED.
SUBCONTRACTOR SHALL NOTIFY THE CONTRACTOR OF ANY DISCREPANCIES
PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION.
18. THE EXISTING CELL SITE IS IN FULL COMMERCIAL OPERATION. ANY
CONSTRUCTION WORK BY SUBCONTRACTOR SHALL NOT DISRUPT THE
EXISTING NORMAL OPERATION. ANY WORK ON EXISTING EQUIPMENT MUST
BE COORDINATED WITH CONTRACTOR. ALSO, WORK SHOULD BE
SCHEDULED FOR AN APPROPRIATE MAINTENANCE WINDOW USUALLY IN LOW
TRAFFIC PERIODS AFTER MIDNIGHT.
19. SINCE THE CELL SITE IS ACTIVE, ALL SAFETY PRECAUTIONS MUST BE
TAKEN WHEN WORKING AROUND HIGH LEVELS OF ELECTROMAGNETIC
RADIATION. EQUIPMENT SHOULD BE SHUTDOWN PRIOR TO PERFORMING
ANY WORK THAT COULD EXPOSE THE WORKERS TO DANGER. PERSONAL RF
EXPOSURE MONITORS ARE ADVISED TO BE WORN TO ALERT OF ANY
DANGEROUS EXPOSURE LEVELS.
20. APPLICABLE BUILDING CODES:
SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL,
STATE, AND LOCAL CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING
JURISDICTION (AHJ) FOR THE LOCATION. THE EDITION OF THE AHJ ADOPTED
CODES AND STANDARDS IN EFFECT ON THE DATE OF CONTRACT AWARD
SHALL GOVERN THE DESIGN.
SUBCONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE
FOLLOWING STANDARDS:
AMERICAN CONCRETE INSTITUTE (ACI) 318; BUILDING CODE
REQUIREMENTS FOR STRUCTURAL CONCRETE;
AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
MANUAL OF STEEL CONSTRUCTION, ASD, FOURTEENTH EDITION;
TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA) 222-G,
STRUCTURAL STANDARDS FOR STEEL
ANTENNA TOWER AND ANTENNA SUPPORTING STRUCTURES; REFER
TO ELECTRICAL DRAWINGS FOR SPECIFIC ELECTRICAL STANDARDS.
FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND
STANDARDS REGARDING MATERIAL, METHODS OF CONSTRUCTION, OR
OTHER REQUIREMENTS, THE MOST RESTRICTIVE REQUIREMENT SHALL
GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT
AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL
GOVERN.
GENERAL NOTES, RF NOTES,
CABLING NOTES
F
FFFFFFFFF F F F F F F F F F F F F F F F F F
F
FFFFFFFFF F F F F F F F F F F F F F F F F F
SITE NAME:
SITE ID:
SITE ADDRESS:
SHEET TITLE:
DRAWING:
4SHM073A
COOLEY HOSPITAL RT
30 LOCUST ST
NORTHAMPTON, MA 01060
HAMPSHIRE COUNTY
COUNTY
A-1
DATE: 08/18/2022
IT IS A VIOLATION OF LAW FOR ANY PERSON UNLESS THEY ARE ACTING UNDER THE
DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT.
UNLESS EXPLICITLY AGREED TO BY THE ENGINEER IN WRITING, THE ENGINEER
DISCLAIMS ALL LIABILITY ASSOCIATED WITH THE REUSE, ALTERATION OR
MODIFICATION OF THE CONTENTS HEREIN.
T-MOBILE NORTHEAST, LLC.
15 COMMERCE WAY, SUITE B
NORTON, MA 02766
PHONE: (508) 286-2700
FAX: (508) 286-2893
- MobileT
NORTHEAST LLC
750 W CENTER ST, SUITE 301
WEST BRIDGEWATER, MA 02379
PHONE: 781.713.4725
ENGINEERING SERVICES, PA
ROOFTOP PLAN
N GRAPHIC SCALE
3/16 INCH = 1 FOOT (22X34)
3/32 INCH = 1 FOOT (11X17)
0 4 848211
A-1
ROOFTOP PLAN
S
E
C
TO
R
1
T
-MO
B
I
L
E
AN
T
ENNA
A
Z
:
6
0
°
SECT
O
R
2
T-MO
BIL
E
A
N
T
E
N
N
A
A
Z:
150 °SECTOR 3T-MOBILE ANTENNA AZ: 290° NOTES
1.CONTRACTOR SHALL MAKE A UTILITY 811 DIG SAFE CALL
TO LOCATE ALL UTILITIES PRIOR TO EXCAVATING.
2.CONSTRUCTION TO COMMENCE UPON COMPLETION OF A
PASSING MOUNT ANALYSIS DATED 03/30/2022.
3.REFER TO THE FINAL RF DATA SHEET FOR FINAL ANTENNA
MODELS AND SETTINGS.
SITE NAME:
SITE ID:
SITE ADDRESS:
SHEET TITLE:
DRAWING:
4SHM073A
COOLEY HOSPITAL RT
30 LOCUST ST
NORTHAMPTON, MA 01060
HAMPSHIRE COUNTY
COUNTY
A-2
DATE: 08/18/2022
IT IS A VIOLATION OF LAW FOR ANY PERSON UNLESS THEY ARE ACTING UNDER THE
DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT.
UNLESS EXPLICITLY AGREED TO BY THE ENGINEER IN WRITING, THE ENGINEER
DISCLAIMS ALL LIABILITY ASSOCIATED WITH THE REUSE, ALTERATION OR
MODIFICATION OF THE CONTENTS HEREIN.
T-MOBILE NORTHEAST, LLC.
15 COMMERCE WAY, SUITE B
NORTON, MA 02766
PHONE: (508) 286-2700
FAX: (508) 286-2893
- MobileT
NORTHEAST LLC
750 W CENTER ST, SUITE 301
WEST BRIDGEWATER, MA 02379
PHONE: 781.713.4725
ENGINEERING SERVICES, PA
EQUIPMENT LAYOUT
GRAPHIC SCALE
1/2 INCH = 1 FOOT (22X34)
1/4 INCH = 1 FOOT (11X17)
0 1 2 424
1
A-2
EXISTING EQUIPMENT PLAN
GRAPHIC SCALE
1/2 INCH = 1 FOOT (22X34)
1/4 INCH = 1 FOOT (11X17)
0 1 2 424
2
A-2
PROPOSED EQUIPMENT PLAN
N
RAN EQUIPMENT
CABINET EXISTING PROPOSED
B160 N/A
6160 AC V1
(1) DUW30
(1) BB6630
(1) BB6648
(1) PSU 4813 XR4A (KIT)
(1) RP6651 FOR L6/L7/N6
NOTE:
RAN EQUIPMENT IS BASED ON RFDS REV2 DATED 08/18/22
SITE NAME:
SITE ID:
SITE ADDRESS:
SHEET TITLE:
DRAWING:
4SHM073A
COOLEY HOSPITAL RT
30 LOCUST ST
NORTHAMPTON, MA 01060
HAMPSHIRE COUNTY
COUNTY
A-3
DATE: 08/18/2022
IT IS A VIOLATION OF LAW FOR ANY PERSON UNLESS THEY ARE ACTING UNDER THE
DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT.
UNLESS EXPLICITLY AGREED TO BY THE ENGINEER IN WRITING, THE ENGINEER
DISCLAIMS ALL LIABILITY ASSOCIATED WITH THE REUSE, ALTERATION OR
MODIFICATION OF THE CONTENTS HEREIN.
T-MOBILE NORTHEAST, LLC.
15 COMMERCE WAY, SUITE B
NORTON, MA 02766
PHONE: (508) 286-2700
FAX: (508) 286-2893
- MobileT
NORTHEAST LLC
750 W CENTER ST, SUITE 301
WEST BRIDGEWATER, MA 02379
PHONE: 781.713.4725
ENGINEERING SERVICES, PA
EQUIPMENT DETAILS
1
A-3
ANTENNA DETAILS
3
A-3
PROPOSED EQUIPMENT CABINET SPECIFICATIONS
ERICSSON 840590966
4
A-3
PROPOSED EQUIPMENT CONDUIT DETAIL
2
A-3
RADIO DETAILS
SIDEFRONT
PLAN
RADIO DIMENSIONS
SITE NAME:
SITE ID:
SITE ADDRESS:
SHEET TITLE:
DRAWING:
4SHM073A
COOLEY HOSPITAL RT
30 LOCUST ST
NORTHAMPTON, MA 01060
HAMPSHIRE COUNTY
COUNTY
A-4
DATE: 08/18/2022
IT IS A VIOLATION OF LAW FOR ANY PERSON UNLESS THEY ARE ACTING UNDER THE
DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT.
UNLESS EXPLICITLY AGREED TO BY THE ENGINEER IN WRITING, THE ENGINEER
DISCLAIMS ALL LIABILITY ASSOCIATED WITH THE REUSE, ALTERATION OR
MODIFICATION OF THE CONTENTS HEREIN.
T-MOBILE NORTHEAST, LLC.
15 COMMERCE WAY, SUITE B
NORTON, MA 02766
PHONE: (508) 286-2700
FAX: (508) 286-2893
- MobileT
NORTHEAST LLC
750 W CENTER ST, SUITE 301
WEST BRIDGEWATER, MA 02379
PHONE: 781.713.4725
ENGINEERING SERVICES, PA
EAST ELEVATION
GRAPHIC SCALE
1/8 INCH = 1 FOOT (22X34)
1/16 INCH = 1 FOOT (11X17)
0 4 8 1681621
1
A-4
SOUTH ELEVATION
F F
F F
F
F
FF F
F
F
FF F
SITE NAME:
SITE ID:
SITE ADDRESS:
SHEET TITLE:
DRAWING:
4SHM073A
COOLEY HOSPITAL RT
30 LOCUST ST
NORTHAMPTON, MA 01060
HAMPSHIRE COUNTY
COUNTY
A-5
DATE: 08/18/2022
IT IS A VIOLATION OF LAW FOR ANY PERSON UNLESS THEY ARE ACTING UNDER THE
DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT.
UNLESS EXPLICITLY AGREED TO BY THE ENGINEER IN WRITING, THE ENGINEER
DISCLAIMS ALL LIABILITY ASSOCIATED WITH THE REUSE, ALTERATION OR
MODIFICATION OF THE CONTENTS HEREIN.
T-MOBILE NORTHEAST, LLC.
15 COMMERCE WAY, SUITE B
NORTON, MA 02766
PHONE: (508) 286-2700
FAX: (508) 286-2893
- MobileT
NORTHEAST LLC
750 W CENTER ST, SUITE 301
WEST BRIDGEWATER, MA 02379
PHONE: 781.713.4725
ENGINEERING SERVICES, PA
ANTENNA PLAN & SCHEDULE
GRAPHIC SCALE
1/4 INCH = 1 FOOT (22X34)
1/8 INCH = 1 FOOT (11X17)
0 4 84821
2
A-5
PROPOSED ANTENNA PLAN
ANTENNA & CABLE NOTES:
1.REFERENCE STRUCTURAL ANALYSIS DATED 03/30/2022 AND MOUNT
ANALYSIS DATED 03/30/2022 BY CENTERLINE COMMUNICATIONS FOR
FURTHER INFORMATION REGARDING THE CAPACITY OF THE EXISTING
STRUCTURE TO SUPPORT THIS EQUIPMENT UPGRADE.
2.REFER TO THE FINAL RF DATA SHEET FOR FINAL ANTENNA SETTINGS.
3.REMOVE ALL UNUSED CABLE, RRUs AND TMAs.
N
GRAPHIC SCALE
1/4 INCH = 1 FOOT (22X34)
1/8 INCH = 1 FOOT (11X17)
0 4 84821
1
A-5
EXISTING ANTENNA PLAN
S
E
C
TO
R
1
T
-MO
B
I
L
E
AN
T
ENNA
A
Z
:
6
0
°
SECT
O
R
2
T-MO
BI
L
E
A
N
T
E
N
N
A
A
Z:
150 °SECTOR 3T-MOBILE ANTENNA AZ: 290°ANTENNA & CABLE SCHEDULE:
LOCATION AZIMUTH RAD
CENTER STATUS TECHNOLOGY ANTENNA MODEL
NO.
MECH
DOWNTILT
ELEC
DOWNTILT TMA/RRU CABLE SIZE CABLE
LENGTH
ALPHABETANOTE: DARK TEXT IN TABLE ABOVE DENOTES PROPOSED EQUIPMENT
60'6x24
HYBRID
CABLES DIPLEXERS
73'-0"A-2 60°
73'-0"B-2 150°GAMMA63'-0"C-1 290°
290°
4480 B71+B85 RRU4°ERICSSON-
840590966 0°PROPOSED
(3) TOTAL 6x24 HYBRID CABLES 258'
PROPOSED
PROPOSED
80'6x24
HYBRID0°
0°
0°
75'6x24
HYBRID4480 B71+B85 RRU4°ERICSSON-
840590966 0°(2) COAX JUMPERS (X2)
(2) FIBER JUMPERS
L700, L600 & N600
ERICSSON-
840590966L700, L600 & N600
L700, L600 & N600
64'-0"
S
E
C
TO
R
1
T
-MO
B
I
L
E
AN
T
ENN
A
A
Z
:
6
0
°
SECT
O
R
2
T-MO
BI
L
E
A
N
T
E
N
N
A
A
Z:
150 °SECTOR 3T-MOBILE ANTENNA AZ: 290°4480 B71+B85 RRU(2) COAX JUMPERS (X2)
(2) FIBER JUMPERS
(2) COAX JUMPERS (X2)
(2) FIBER JUMPERS
4°
2°
2°
290°64'-0"
(3) TOTAL 6x24 HYBRID CABLES 78.6M
SITE NAME:
SITE ID:
SITE ADDRESS:
SHEET TITLE:
DRAWING:
4SHM073A
COOLEY HOSPITAL RT
30 LOCUST ST
NORTHAMPTON, MA 01060
HAMPSHIRE COUNTY
COUNTY
SN-1
DATE: 08/18/2022
IT IS A VIOLATION OF LAW FOR ANY PERSON UNLESS THEY ARE ACTING UNDER THE
DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT.
UNLESS EXPLICITLY AGREED TO BY THE ENGINEER IN WRITING, THE ENGINEER
DISCLAIMS ALL LIABILITY ASSOCIATED WITH THE REUSE, ALTERATION OR
MODIFICATION OF THE CONTENTS HEREIN.
T-MOBILE NORTHEAST, LLC.
15 COMMERCE WAY, SUITE B
NORTON, MA 02766
PHONE: (508) 286-2700
FAX: (508) 286-2893
- MobileT
NORTHEAST LLC
750 W CENTER ST, SUITE 301
WEST BRIDGEWATER, MA 02379
PHONE: 781.713.4725
ENGINEERING SERVICES, PA
STRUCTURAL NOTES &
SPECIAL INSPECTIONS
BEFORE CONSTRUCTION
DURING CONSTRUCTION
REQUIRED
4
5
AFTER CONSTRUCTION
REQUIRED MODIFICATION INSPECTOR REDLINE
OR RECORD DRAWINGS 6
REQUIRED PHOTOGRAPHS
REQUIRED INSPECTIONS AND SITE REVIEW DOCUMENT AS A
CONDITION OF THE BUILDING PERMIT THE FOLLOWING
INSPECTIONS AND SITE REVIEWS IDENTIFIED BY THE BUILDING
OFFICIAL ARE REQUIRED FOR WORK PER THE
9TH EDITION OF THE MASSACHUSETTS STATE BUILDING CODE,
780 CMR, SECTION110 AND CHAPTER 17
REQUIRED SITE REVIEW AND DOCUMENTATION FOR PORTIONS OR PHASES
CONSTRUCTION 1 6 7
SITE REVIEW AND DOCUMENTATION X SITE REVIEW AND
DOCUMENTATION X
5
4
X
STRUCTURAL NOTES:SPECIAL INSPECTIONS (REFERENCE IBC CHAPTER 17):
NOTES:
NOTES:
X
MASSACHUSETTS AMENDMENTS TO THE IBC
(REFERENCE 780 CMR):
SITE NAME:
SITE ID:
SITE ADDRESS:
SHEET TITLE:
DRAWING:
4SHM073A
COOLEY HOSPITAL RT
30 LOCUST ST
NORTHAMPTON, MA 01060
HAMPSHIRE COUNTY
COUNTY
S-1
DATE: 08/18/2022
IT IS A VIOLATION OF LAW FOR ANY PERSON UNLESS THEY ARE ACTING UNDER THE
DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT.
UNLESS EXPLICITLY AGREED TO BY THE ENGINEER IN WRITING, THE ENGINEER
DISCLAIMS ALL LIABILITY ASSOCIATED WITH THE REUSE, ALTERATION OR
MODIFICATION OF THE CONTENTS HEREIN.
T-MOBILE NORTHEAST, LLC.
15 COMMERCE WAY, SUITE B
NORTON, MA 02766
PHONE: (508) 286-2700
FAX: (508) 286-2893
- MobileT
NORTHEAST LLC
750 W CENTER ST, SUITE 301
WEST BRIDGEWATER, MA 02379
PHONE: 781.713.4725
ENGINEERING SERVICES, PA
ANTENNA & RRU MOUNTING
DETAILS
NOTES FOR ANTENNA MOUNTS:
1.AIR6449: ERICSSON R2A PIPE MOUNT KIT
2.840590966: 85021009 TILT BRACKET PIPE MOUNT
KIT
3.APXVAARR24-43-U-NA20: APM40-5E PIPE MOUNT
KIT
1
S-1
TYPICAL ANTENNA & RRU MOUNTING DETAIL
SITE NAME:
SITE ID:
SITE ADDRESS:
SHEET TITLE:
DRAWING:
4SHM073A
COOLEY HOSPITAL RT
30 LOCUST ST
NORTHAMPTON, MA 01060
HAMPSHIRE COUNTY
COUNTY
S-2
DATE: 08/18/2022
IT IS A VIOLATION OF LAW FOR ANY PERSON UNLESS THEY ARE ACTING UNDER THE
DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT.
UNLESS EXPLICITLY AGREED TO BY THE ENGINEER IN WRITING, THE ENGINEER
DISCLAIMS ALL LIABILITY ASSOCIATED WITH THE REUSE, ALTERATION OR
MODIFICATION OF THE CONTENTS HEREIN.
T-MOBILE NORTHEAST, LLC.
15 COMMERCE WAY, SUITE B
NORTON, MA 02766
PHONE: (508) 286-2700
FAX: (508) 286-2893
- MobileT
NORTHEAST LLC
750 W CENTER ST, SUITE 301
WEST BRIDGEWATER, MA 02379
PHONE: 781.713.4725
ENGINEERING SERVICES, PA
SLED MOUNT
REINFORCEMENT DETAILS
NOTE:
ANTENNA MOUNTING PIPES AND APPURTENANCES
NOT SHOWN FOR CLARITY.
2
S-2
GRAPHIC SCALE
3/4 INCH = 1 FOOT (22X34)
3/8 INCH = 1 FOOT (11X17)
0 1 2 424
1
S-2
SLED MOUNT REINFORCEMENT
GRAPHIC SCALE
3 INCHES = 1 FOOT (22X34)
1-1/2 INCHES = 1 FOOT (11X17)
0 0.5 11
2
S-2
CONNECTION DETAIL
SITE NAME:
SITE ID:
SITE ADDRESS:
SHEET TITLE:
DRAWING:
4SHM073A
COOLEY HOSPITAL RT
30 LOCUST ST
NORTHAMPTON, MA 01060
HAMPSHIRE COUNTY
COUNTY
G-1
DATE: 08/18/2022
IT IS A VIOLATION OF LAW FOR ANY PERSON UNLESS THEY ARE ACTING UNDER THE
DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT.
UNLESS EXPLICITLY AGREED TO BY THE ENGINEER IN WRITING, THE ENGINEER
DISCLAIMS ALL LIABILITY ASSOCIATED WITH THE REUSE, ALTERATION OR
MODIFICATION OF THE CONTENTS HEREIN.
T-MOBILE NORTHEAST, LLC.
15 COMMERCE WAY, SUITE B
NORTON, MA 02766
PHONE: (508) 286-2700
FAX: (508) 286-2893
- MobileT
NORTHEAST LLC
750 W CENTER ST, SUITE 301
WEST BRIDGEWATER, MA 02379
PHONE: 781.713.4725
ENGINEERING SERVICES, PA
GROUNDING & ONE LINE
DIAGRAM4
G-1
ANTENNA/RRU GROUNDING DETAIL
3
G-1
GROUND WIRE SCHEDULE2
G-1
GROUND BAR DETAIL
5
G-1
GROUND LUG DETAIL
1
G-1
GROUNDING RISER DIAGRAM
1
E-1
ELECTRICAL ONE LINE DIAGRAM