Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
37-123 (4)
BP-2022-1030 329 ROCKY HILL RD COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 37-123-001 CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2022-1030 PERMISSIONIS HEREBY GRANTED TO: Project# 2022 SOLAR Contractor: License: Est. Cost: 41000 TESLA ENERGY OPERATIONS INC 101687 Const.Class: Exp.Date:09/13/2022 Use Group: Owner: GROVER SOOD VIKRAM &RUCHI Lot Size (sq.ft.) Zoning: SR Applicant: TESLA ENERGY OPERATIONS INC Applicant Address Phone: Insurance: 24 ST. MARTIN DRIVE BLDG 2 UNIT 978-570-6622 WC 1074584-04 II MARLBOROUGH, MA 01752 ISSUED ON:08/22/2022 TO PERFORM THE FOLLOWING WORK: INSTALL 36 PANEL 14.4 KW ROOF MOUNT SOLAR SYSTEM WITH 2 BATTERIES (13.5 KW TOTAL) IN GARAGE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: +. '1;• .> . CIPPV Fees Paid: $75.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Office of the Building Commissioner / ./8- :'—'. C' '' ',/i,/2 __ ,,,. i The Commonwealth of Massachusetts 00 . Vti Board of Building Regulations and Standards �Q192 UNII`IOPALITY Massachusetts State Building Code, 780 C 01),r) /USE Building Permit Application To Construct, Repair, Renovate Or"be Reviped Mar 2011 One-or Two-Family Dwelling -'�.'ns��O'�s 1 This Section For Official Use Only Buildinzi it Number: 6/2��' (f Date Applied: �J ' KOx /G'2 8.72-2'127 Building Official(Print Name) Signature Date SECTION 1: SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map& Parcel Numbers 329 Rocky Hill Rd. 37 - 123 001 1.1 a Is this an accepted street?yes V no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: LA307 1010 - SFR Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private 0 Zone: Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Vikram Sood Northampton, MA 01062 Name(Print) City,State,ZIP 329 Rocky Hill Road (413) 427-4757 No.and Street Telephone Email Address SECTION 3: DESCRIPTION_ / OF PROPOSED WORK2(check all that apply) New Construction 0 Existing Building&f Owner-Occupied V( Repairs(s) 0 Alteration(s) 0 Addition 0 Demolition 0 Accessory Bldg. 0 Number of Units 1 Other Specify: Rooftop Solar Brief Description of Proposed Work2: Install solar electric panel to the existing roof of a home interconnected with the electrical grid 14.4 kW 36 panels with 2 Tesla Powerwalls (rated at 13.5 kWh total) installed in the residence garage SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1. Building $12,000.00 1. Building Permit Fee: $ Indicate how fee is determined: 2.Electrical $ 29 000.00 0 Standard City/Town Application Fee ❑Total Project Cost (Item 6)x multiplier x 3. Plumbing $ 2. Other Fees: $ 4. Mechanical (HVAC) $ List: 5. Mechanical (Fire $ 4 / J Suppression) Total All Fees: $ Check No. ?+ Check Amount: Cash Amount: 6.Total Project Cost: $ 41 ,000.00 0 Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS—I 01687 09/13/22 Daniel F o n z i License Number Expiration Date Name of CSL Holder 24 St. Martins Drive List CSL Type(see below) No.and Street Type Description U Unrestricted(Buildings up to 35,000 cu.ft.) Marlborough, MA 01752 R Restricted 1&2 Family Dwelling City/Town,State,ZW M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances (978)420-2476 dfonzi@tesla.com I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 168572 03/07/23 Testa Energy Operations Inc HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 901 Page Avenue npears@tesla.com No.and Street Email address Fremont CA 94538 (508) 907-1450 City/Town,State,ZIP Telephone SECTION 6:WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152. § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes Vr No .❑ SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Tesla Energy Operations Inc to act on my behalf,in all matters relative to work authorized by this building permit application. Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER' OR AUTHORIZED AGENT DECLARATION By entering my name below, I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. • �B G 08/16/22 Print Owner's or Authorized Agent's Name(Elect Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L. c. 142A. Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq. ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq. ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" City of Northampton C, V c , Massachusetts ``� DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street • Municipal Building r Northampton, MA 01060 tJ t`t 3,)\\' CONSTRUCTION DEBRIS AFFIDAVIT (FOR ALL DEMOLITION AND RENOVATION PROJECTS) In accordance of the provisions of MGL c 40, S54, a condition of Building Permit Number is that all debris resulting from this work shall be disposed of in a properly licensed waste disposal facility, as defined by MGL c 111, S 150A. The debris will be disposed of in: EL Harvey & Sons shop dumpster Location of Facility: 24 St. Martin Dr., Marlborough MA 01752 _ The debris will be transported by: Workcrew Name of Hauler: EL Harvey & Sons Signature of Applicant: Z7a41.4421 fB' Date: 08/16/22 The Commonwealth of Massachusetts 1� ; /. Department of Industrial Accidents 9.0= 1 Congress Street, Suite 100 of= Boston, MA 02114-2017 " www.mass.gov/dia it Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name (Business/Organization/Individual): Tesla Energy Operations Address: 24 St. Martins Dr., Building 2, Unit 11 City/State/Zip: Marlborough, MA 01752 Phone#: (508) 907-1450 Are you an employer?Check the appropriate box: Type of project(required): I.igi lain a employer with 200 employees(full and/or part-tune)."` 7. ❑New construction 2.0 I am a sole proprietor or partnership and have no employees working for me in 8. ❑ Remodeling any capacity.[No workers'comp.insurance required.] 9. ❑Demolition 3.❑I am a homeowner doing all work myself.[No workers'comp.insurance required.]e 10 ❑ Building addition 4.0 I am a homeowner and will be hiring contractors to conduct all work on my property. I will ensure that all contractors either have workers'compensation insurance or are sole 11.0 Electrical repairs or additions proprietors with no employees. 12.0 Plumbing repairs or additions 5.0 I am a general contractor and I have hired the sub-contractors listed on the attached sheet. These sub-contractors have employees and have workers'comp.insurance 2 13.El Roof repairs 6.0 We area corporation and its officers have exercised their right of exemption per MGL c. 14.]g]Other Rooftop Solar 152,§I(4),and we have no employees.[No workers'comp insurance required.] *Any applicant that checks box#1 must also till out the section belom.'showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. IC:ontractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Zurich American Insurance _ Policy#or Self-ins.Lic.#: 1074584-03 Expiration Date: 10/31/2022 Job Site Address: 329 Rocky Hill Rd. city/state/zip: Northampton, MA 01062 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certiffy under the pains and penalties of perjury that the information provided above is true and correct. 2 Signature: P;fri b Date: 08/16/22 Phone#: Official use only. Do not write in this area, to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1. Board of Health 2.Building Department 3.City/Town Clerk 4. Electrical Inspector 5.Plumbing Inspector 6. Other Contact Person: Phone#: Office of Consumer Affairs and Business Regulation 1000 Washington Street - Suite 710 Boston. Massachusetts 02118 Home Improvement Contractor Registration Type: Supplement Card Registration: 168572 TESLA ENERGY OPERATIONS. INC. Expiration: 03/07/2023 901 PAGE AVENUE FREMONT. CA 94538 Update Address and Return Card. Office of Consumer Affairs&Business Regulation HOME IMPROVEMENT CONTRACTOR Registration valid for individual use only TYPE:Supplement Card before the expiration date. If found return to: Registration Expiration Office of Consumer Affairs and Business Regulation 168572 03/07-2023 1000 Washington Street -Suite 710 TESLA ENERGY OPERATIONS. INC. Boston,MA 02118 DANIEL FONZI 155 FEDERAL ST STE 700 Undersecretary Not valid without signature BOSTON.MA 02110 r . Commonwealth of Massachusetts Division of Professional Licensure Board of Building Regulations and Standards Constructionl5upervisor CS-101687 • Expires: 09/13/2022 DANIEL D FONZI 390 ANDOVER STREET . WILMINGTON MA 01887 Commissioner di t �,°, WF"' A�oRD® CERTIFICATE OF LIABILITY INSURANCE DAT1 E(MM/,D/YYYY) THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). i PRODUCER NAMEACT Kayla Ferrell MARSH RISK& INSURANCE SERVICES FOUR EMBARCADERO CENTER,SUITE 1100 (NC No.Ed): 415743 8025 FAX No): CALIFORNIA LICENSE NO.0437153 E-MAIL SAN FRANCISCO,CA 94111 ADDRESS: Attn:SanFrancisco.Certs@marsh.com/FAX 212-948-0398 INSURER(S)AFFORDING COVERAGE NAIC N CN104275261-STND-GAWEO-21- INSURER A:Zurich American Insurance Company 16535 INSTesla Energy Operations Inc. INSURER B:WA N/A 901 Page Avenue INSURER C:American Zurich Insurance Comjpy _ 40142 Fremont,CA 94538 INSURER D: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-003794942-01 REVISION NUMBER: 1 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT.TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL LTR TYPE OF INSURANCE INSD SWVD POLICY NUMBER POLICY EFF POLICY EXP LIMITS (MM/DD/YYYY) (MM/DD/YYYY) A X COMMERCIAL GENERAL LIABILITY GL01074588-04 10/31/2021 10/31/2022 EACH OCCURRENCE $ 2,500,000 CLAIMS-MADE X OCCUR Includes Host Liquor Liability DAMAGE TO PREMISES(Ea oNTED ccurrence) $ 2,500,000 X SIR:$750,000 MED EXP(Any one person) $ 5,000 X Tort Contrac Liab,No XCU Exd PERSONAL&ADV INJURY $ 2,500,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 10,000,000 L J PRO X POLICY LOC PRODUCTS-COMP/OP AGG $ 2,500,000 JECT OTHER: $ A AUTOMOBILE LIABILITY BAP 1074586-04 10/31/2021 10/31/2022 COMBINED SINGLE LIMIT $ 1,000000 (Ea accident) X ANY AUTO BODILY INJURY(Per persorO $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY (Per_accident) _ _ I UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ $ C 'WORKERS COMPENSATION WC 1074583-04(AOS) 10/31/2021 10/31/2022 X PER X oTH- AND EMPLOYERS'LIABILITY C Y/ _ _ STATUTE _ ER _ N WC 1074584-04(MA,WI) 10/31/2021 10/31/2022 1,000,000 ANYPROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ A OFFICER/MEMBER EXCLUDED? N N/A CA XSWC EWS 1074585-04($50M is 10/31/2021 10/31/2022 (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under VW SIR;$1 M EE/EA is XS$10M SIR) E.L.DISEASE-POLICY LIMN $ 1,000,000 DESCRIPTION OF OPERATIONS below DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Evidence of Insurance CERTIFICATE HOLDER CANCELLATION Tesla Inc and all its subsidiaries SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 45500 Fremont Blvd THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Fremont,CA 94538 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE Need Red &T aircucee Setviee4 ©1988-2016 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD ^� 1 Tesla Roa ,Austin.TX 78725 ■ ■ P 650 681 510 F 650 681 5101 V rsion#95.2-1 August 15,2022 Certification Letter Project/Job#0103397 Project Address: Sood Residence 329 Rocky Hill Rd Northampton,MA 01062 AHJ Northampton SC Office Marlborough Design Criteria: -Applicable Codes=MA Res.Code,9th Edition/IEBC,ASCE 7-10,and 2015 NDS -Risk Category=II -Wind Speed=120 mph(3-s Gust-Vult),Exposure Category C,Partially/Fully Enclosed Method -Ground Snow Load=40 psf -MP1:Roof DL=11 psf,Roof LL/SL=35 psf(Non-PV),Roof LUSL=21.1 psf(PV) -MP2:Roof DL=11 psf,Roof LL/SL=35 psf(Non-PV),Roof LUSL=21.1 psf(PV) -MP3:Roof DL=11 psf,Roof LUSL=35 psf(Non-PV),Roof LUSL=21.1 psf(PV) -MP4:Roof DL=11 psf,Roof LL/SL=35 psf(Non-PV),Roof LUSL=21.1 psf(PV) -MP5:Roof DL=11 psf,Roof LL/SL=35 psf(Non-PV),Roof LUSL=21.1 psf(PV) -MP6:Roof DL=11 psf,Roof LUSL=35 psf(Non-PV),Roof LUSL=21.1 psf(PV) -MP7:Roof DL=11 psf,Roof LL/SL=35 psf(Non-PV),Roof LUSL=21.1 psf(PV) Note: Per IBC 1613.1; Seismic check is not required because Ss=0.17<0.4g and Seismic Design Category(SDC)=B<D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from Tesla.Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation,I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/dots submitted for approval. �� 9tip\OF M4Ssc c RYAN yG ATWELL mi C CIVIL No. 56114 t Digitally signed by A-9 4'o STEO4<Q Ryan Ryan Atwell c8S/ONAL ENC' Atwell Date:2022.08.15 11:52:04-05'00' 08/15/2022 "STRUCTURAL ONLY" T 1 Tesla Road,Austin,TX 78725 -- - P 650 681 5100 F 650 681 5101 Version#95.2-1 HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1 48" 19" 41" NA _ Staggered 32.3% MP2 48" 19" 41" NA Staggered 32.3% MP3 48" 19" 41" NA Staggered 32.3% MP4 48" 19" 41" NA Staggered 32.3% MP5 48" 19" 41" NA _ Staggered 32.3% MP6 48" 19" 41" NA Staggered 32.3% MP7 48" 19" 41" NA Staggered 32.3% Portrait Hardware-Portrait Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1 32" 11" 74" NA _ Staggered 38.9% MP2 32" 11" 74" NA Staggered 38.9% MP3 32" 11" 74" NA - Staggered 38.9% MP4 32" 11" 74" NA _ Staggered 38.9% MP5 32" 11" 74" NA Staggered 38.9% MP6 32" 11" 74" NA Staggered 38.9% MP7 32" 11" 74" NA Staggered 38.9% Mounting Plane Roof Pitch Qualification Results (Degrees) Member Evaluation Results MP1 34° Member Impact Check OK MP2 34° Member Impact Check OK MP3 34° Member Impact Check OK MP4 34° Member Impact Check OK MP5 34° Member Impact Check OK MP6 34° Member Impact Check OK MP7 34° Member Impact Check OK ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED NEW PROJECTS WITH NATIONAL GRID USA WILL NO BUILDING CONC CONCRETE DC DIRECT CURRENT POWER—CONDITIONING INVERTER. LONGER APPLY FOR THE SMART REBATE EGC EQUIPMENT GROUNDING CONDUCTOR (E) 2. A NATIONALLY — RECOGNIZED TESTING INCENTIVES PROGRAM. SMART METERS WILL NO EXISTING EMT ELECTRICAL METALLIC TUBING FSB LABORATORY SHALL LIST ALL EQUIPMENT IN LONGER BE INSTALLED AND WO# WILL NOT BE FIRE SET—BACK GALV GALVANIZED GEC GROUNDING COMPLIANCE WITH ART. 110.3. PROVIDED. ELECTRODE CONDUCTOR GND GROUND HDG HOT 3. WHERE ALL TERMINALS OF THE DISCONNECTING DIPPED GALVANIZED I CURRENT Imp CURRENT AT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, MAX POWER Isc SHORT CIRCUIT CURRENT kVA A SIGN WILL BE PROVIDED WARNING OF THE KILOVOLT AMPERE kW KILOWATT LBW LOAD HAZARDS PER ART. 690.17. BEARING WALL MIN MINIMUM (N) NEW NEUT 4. EACH UNGROUNDED CONDUCTOR OF THE NEUTRAL NTS NOT TO SCALE OC ON CENTER PL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PROPERTY LINE POI POINT OF INTERCONNECTION PHASE AND SYSTEM PER ART. 210.5. PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS 5. CIRCUITS OVER 250V TO GROUND SHALL COMPLY STEEL STC STANDARD TESTING CONDITIONS TYP WITH ART. 250.97, 250.92(B). TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V 6. DC CONDUCTORS EITHER DO NOT ENTER BUILDING VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE OR ARE RUN IN METALLIC RACEWAYS OR AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 7. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 8. MODULE FRAMES SHALL BE GROUNDED AT THE UL — LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. VICINITY MAP INDEX Christ United t Sheet 1 COVER SHEET Sheet 2 SITE PLAN Methodist Church • Sheet 3 STRUCTURAL VIEWS Sheet 4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES Sheet 5 THREE LINE DIAGRAM X Cutsheets Attached 2 828122A 1. ALL WORK TO BE DONE TO THE 9TH EDITION Wu ELEC HIE # OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH T� ,. THE 2020 NATIONAL ELECTRIC CODE INCLUDING 1.• MASSACHUSETTS AMENDMENTS. I -- aiitn.: MODULE GROUNDING METHOD: ZEP SOLAR -. ,� AHJ: Northampton .74 �coe REV BY DATE COMMENTS ,i F♦ '� 4 REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) echnologies. U.S. Geological Survey, USDA Farm Service Agency CONFIDENTIAL- THE INFORMATION HEREIN ,p6 NUMBEFt J B-010 3 3 9 7 00 CUSTOMER DESCRIPTION: DESIGN: CBENEFIT OF ANYONE EXCEPT TESLA INC.,ONTAINED SHALL NOT BE USED FOR THE vikram sood 14.4 KW PV ARRAY Usman Ali Iftikhar T 5 L inSHALL IT BE DISCLOSED IN NOR 101"""�sue,;WHOLE OR IN 329 Rock Hill Rd 13.5 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENT'S ZS Comp V4 w Metal—Flashing y ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: Northampton, MA 01062 THE SALE AND USE OF THE RESPECTIVE (36) Tesla # T400H PAGE NAME SHEET; REV DATE TESLA EQUIPMENT, LA THE WRITTEN INVERTER; 4134274757 1 $ 12 PERMISSION OF TESLA INC.INc. Multiple Inverters COVER SHEET / /2022 -- - - ---- _ _ U�1 H: 34° (8:12) ARRAY PITCH:34° (8:12) ACCESSIBLE AND LOCKABLE A/C DISCONNECT - -- - — -- -- Mpi —AZIMUTH:230 ARRAY AZIMUTH:230 MATERIAL: Comp Shingle STORY: 2 Stories A. POWERWALL CHARACTERISTICS PITCH: 34° (8:12) ARRAY PITCH:34° (8:12) -MAKE: TESLA MP2 AZIMUTH: 140 ARRAY AZIMUTH: 140 -MODEL: AC-DC POWERWALL+ INVERTER MATERIAL: Comp Shingle STORY: 2 Stories -MAX. CAPACITY: 5.0KW AC PITCH: 34° (8:12) ARRAY PITCH:34° (8:12) -OUTPUT VOLTAGE: 240V MP3 AZIMUTH:320 ARRAY AZIMUTH:320 -PHASING: SINGLE PHASE 411 MATERIAL: Comp Shingle STORY: 2 Stories B. TOTAL AC SIZE OF PV INVERTER: 11.4 KW PITCH: 34° (8:12) ARRAY PITCH:34° (8:12) C. TOTAL AC SIZE OF POWERWALLS: 0 KW MP4 AZIMUTH: 140 ARRAY AZIMUTH: 140 D. TOTAL AC SIZE OF SYSTEM (B+C): 11.4 KW *A. - MATERIAL:Comp Shingle STORY: 2 Stories E. TOTAL DC SIZE OF PV: 14.4 KW PITCH: 34° (8:12) ARRAY PITCH:34° (8:12) MP5 AZIMUTH:50 ARRAY AZIMUTH:50 ONE POWERWALL TO BE INSTALLED. ESS SYSTEM IS LESS MATERIAL: Comp Shingle STORY: 2 Stories THAN 20 KWH. PITCH: 34° (8:12) ARRAY PITCH:34° (8:12) MP6 AZIMUTH: 140 ARRAY AZIMUTH: 140 ESS UNITS TO BE MOUNTED IN ATTACHED GARAGE. MATERIAL: Comp Shingle STORY: 2 Stories LEGEND O (E) UTILITY METER & WARNING LABEL INVERTER W/ INTEGRATED DC DISCO © ® WARNING LABELS lipprt & RELAY�. .�.� AUTOMATIC RELAY DC DC DISCONNECT & WARNING LABELS �a Ali AC AC DISCONNECT & WARNING LABELS NW ,xa �, 0 DC JUNCTION/COMBINER BOX & LABELS .�, c ��*al r E� ENERGY STORAGE SYSTEM FOR STAND Aiiiiiiii �♦ �a, ,, ALONE OPERATION •IID O DISTRIBUTION PANEL & LABELS w „Is7t (E'DRIVEW"" Lc LOAD CENTER & WARNING LABELS �� P�-H OF M4`pS v_,.. ��Q ya`� q' O DEDICATED PV SYSTEM METER �' stia o RYAN M. tiN$44e z ATWELL RSDRAPID SHUTDOWN © Front Of Housetp CIVIL E � No.56114 STANDOFF LOCATIONS Ago 9FcAS7EF'``o�'Q CONDUIT RUN ON EXTERIOR tgir,QA `88/ONAL C'� — GATE/FECEN ON INTERIOR � 0 HEAT PRODUCING VENTS ARE RED TESLA BACK UP SWITCH P� 08/15/2022 r,_, TO BE INSTALLED ON I% 'I INTERIOR EQUIPMENT IS DASHED (N) CUSTOMER ME1ER SOCKET "STRUCTURAL ONLY" L—'J Digitally signed Ryan by Ryan Atwell SITE PLAN N Atwell Diate:2022.08.15 /_ 11:45:a6 0500' Scale:1/16" = 1' W j E 01' 16' 32' _• ■ •• S • CONFIDENTIAL— THE INFORMATION HEREIN JDB NUMBER: J B—010 3 3 9 7 00 CUSTOMER: DESCRIPTION: DESIGN: _ CONTAINED SHALL NOT BE USED FOR THE vikram sood 14.4 KW PV ARRAY Usman Ali Iftikhar T 5 L in OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Metal-Flashing 329 Rocky Hill Rd 13.5 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS Northampton, MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: THE SALE AND USE OF THE RESPECTIVE (36) Tesla # T400H TESLA EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE PERMISSION OF TESLA INC. Multiple Inverters 4134274757 SITE PLAN 2 8/12/2022 Ill6. E� (N) PV MODULE .111I (E) MOUNTING PLANE (MP) . 0I SV TYPICAL PV SIDE VIEW NTS PV MODULE 5/16" BOLT WITH INSTALLATION ORDER FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) �2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. co. `�"�' ZEP COMP MOUNT C � �i i-An l� mciism N j , OF Mq,. �� Y 3 INSERT FLASHING. � s9c ZEP FLASHING C 1 T ( ) t� : •1 � �o�' RYAN M. co tiG (E) COMP. SHINGLE v'l �m� AT LL �, illiJIiI Co PLACE MOUNT. o CIVIL cn No. 56114 (E) ROOF DECKINGVALOIS (5) INSTALL LAG BOLT WITH A9o,,<FFGis-re?' \<``� 5 16" DIA STAINLESS (5) C SEALING WASHER. SSioNAL EN / LOWEST MODULE SUBSEQUENT MODULES i STEEL LAG BOLT (6) INSTALL LEVELING FOOT WITH 08/15/2022 WITH SEALING WASHER BOLT & WASHERS. - "STRUCTURAL ONLY" (E) RAFTER4101 STANDOFF Scale: 1 1/2" = 1' J B-010339 7 00 CUSTOMER DESCRIPTION: DESIGN: wimp CONFIDENTIAL - THE INFORMATION HEREIN a6 NUMBER vikram sood 14.4 KW PV ARRAY Usman Ali Iftikhar TESL n CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT IESLA INC., NOR MOUNTING SYSTEM: 329 RockyHill Rd 13.5 KWH ENERGY STORAGE SYSTEM SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Metal-Flashing PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: Northampton, MA 01062 THE SALE AND USE OF THE RESPECTK (36) Tesla # T400H TESLA EQUIPMENT, WITHOUT THE WRITTEN ,AMER: 4134274757 PAGE NAME: SHEET: REV DATE PERMISSION OF TESLA INC. Multiple Inverters STRUCTURAL VIEWS 3 8/12/2022 Jobsite Specific Design Criteria Design Code ASCE 7-10 Risk Category II Table 1.5-1 Ultimate Wind Speed V—Ult 120 Fig. 1609A Exposure Category C Section 26.7 Ground Snow Load p9 40 Table 7-1 Edge Zone Width a 7.2 ft Fig. 30.4-2A to 30.4-2C MP Specific Design Information MP Name MP1 MP2 MP3 MP4 MP5 MP6 MP7 Roofing Comp Shingle Comp Shingle Comp Shingle Comp Shingle Comp Shingle Comp Shingle Comp Shingle Standoff ZS Comp V4 w ZS Comp V4 w ZS Comp V4 w ZS Comp V4 w ZS Comp V4 w ZS Comp V4 w ZS Comp V4 w Metal—Flashing Metal—Flashing Metal—Flashing Metal—Flashing Metal—Flashing Metal—Hashing Metal—Flashing Pitch 34 34 34 34 34 34 34 SL/RLL PV 21.0 21.0 21.0 21.0 21.0 21.0 21.0 SL/RLL: Non—PV 35.0 35.0 35.0 35.0 35.0 35.0 35.0 Standoff Spacing and Layout MP Nome MP1 MP2 MP3 MP4 MP5 MP6 MP7 Landscape X—Spacing 48 48 48 48 48 48 48 Landscape 19 19 19 19 19 19 19 X—Cantilever 11, Landscape Y—Spacing 41 41 41 41 41 41 41 Landscape _ — _ — — — _ �P,AN OF Mgss Y—Cantilever �Sl \y Portrait X Spocin9 32 32 32 32 32 32 32 ATINELL m Portrait X—Cantilever 11 11 11 11 11 11 11 CIVIL —I Portrait Y—Spacing 74 74 74 74 74 74 74 No. 56114 Portrait Y—Contilever A90c��GfSTEP������� Layout Staggered Staggered Staggered Staggered Staggered Staggered Staggered eSS/ONAL EN X and Y are maximums that are always relative to the structure framing that supports the PV. X is across rafters and Y is along rafters. 08/15/2022 "STRUCTURAL ONLY" CONFIDENTIAL — THE INFORMATION HEREIN J08 NUMBER: J 3-010 3 3 9 7 00 CUSTOMER: DESCRIPTION: DESIGN: _CONTAINED SHALL NOT BE USED FOR THE vikram sood 14.4 KW PV ARRAY Usman All Iftikhar T 5 L n BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Metal—Flashing 329 Rocky Hill Rd 13.5 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH Northampton, THE SALE AND USE OF THE RESPECTIVE (36) Tesla # T400H SHEET: REV DATE: TESLA EQUIPMENT, WITHOUT THE WRITTEN !MUTER: PAGE NAME: PERMISSION OF TESLA INC. 4134274757 Multiple Inverters UPLIFT CALCULATIONS 4 8/12/2022 MAIN PANEL SPECS GENERAL NOTES PRODUCT SPECS MODULE SPECS LICENSE Panel Number:LC4040B1200 Inv 1: DC Ungrounded 1 - (1) Powerwdl+ [240v)p850000-oo-c /Pvl Assy. 1536000-25-F - (36) Tale I T400H HIC #168572 Meter Number:16419742 Inv 2: DC Ungrounded PV Module, 400W, 371.5 PTC, 40MM, Block Frame, MC4/1AC4-EV02, ZEP, 1000V ELEC 22812A Underground Service Entrance 2 - (1) 3.8 kW Tesla Inc 1534000-00-F(240V) Voc: 45.3 Vpmax: 37.13 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E-STOP Product 1 E 200A/2P MAIN CIRCUIT BREAKER BUTTON 7 8 A r (E) WIRING (N) 125A LOAD CENTER i n Dc+TESLA BACKUP SWITCH15 AC DISCONNECT 14 W ENERGY STORAGE DG MP3: lx10X 11 \ zaov k�� DC+ • /\ DC+ I I 0 Z Y �,J �� DC- 1111 U DC- MP5: 1x6 "EMI70A 50Al2P 12V ka— DC+ EGC a L20 • -♦ •- A -----•=i (1 Ll •� DC- I �/;`J DC+ AA. 0 CO c N ,, DC- 1 I 6 DP MP1: lx6 GND EGC ____ DC+ DC+,co ID m <�- --� —� —— 1--�-i N �J--- �j iA + i Da MP2,MP4: lx6 ,I, I I I GND I EGC __ktEGC I I Product 2 ' I I (1)Conduit Kit; 3/4"EMT I I I I ® - 0 240V A 10 A 4 DC+ —/ N L2 L1 20Al2P • • _ E C MP7: lx2 TO 120/240V I c= I �• kr� DC+ 1 SINGLE PHASE I GEC I - DC I UTILITY SERVICE -fi L---------- EGC si •� DC+ • DC+—/ MI I —� Da0 ODc b MP6: lx6 I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN GND I____EGC_ EGC J I I 2� � 1 I • I — ACCESSIBLE AND LOCKABLE — A/C DISCONNECT I I • (1)Conduit Kit; 3/4" EMT - CONDUCTORS RATED TO 100A OR GREATER MAY BE INSTALLED WITH STORAGE CHARGING CAPABILITY: I I - -• ALUMINUM RATED EQUIVALENT WIRE SIZE AND THE RESULTING CONDUIT SIZE.GENERATION ONLY --• • REFERENCE THE 'WIRE & CONDUIT SIZE EQUIVALENCE TABLE' ATTACHED TO _L__ (E) LOADS THE PLANSET. — — Panel Limit feature for Powerwall unit(s) STORAGE DISCHARGING CAPABILITY: A. POWERWALL CHARACTERISTICS TESLA BACK UP SWITCH to be utilized -MAKE: TESLA RESTRICTED ELECTRIC GRID OR ONSITE LOAD Field label to be at the point of interconnection: -MODEL AC-DC POWERWALL+ INVERTER TO BE INSTALLED ON (E) 200A "PCS Controlled Current Setting: 200A -MAX. CAPACITY: 5.0KW AC CONDUCTORS RATED TO 100A OR GREATER MAY BE (N) CUSTOMER METER DISTRIBUTION PANEL -PHASING:VOLTAGE: 240V INSTALLED WITH ALUMINUM RATED EQUIVALENT WIRE SIZE SOCKET The maximum output current from this system towards B. TOTAL AC SIZE OF PV INVERTER: 11.4 KW AND THE RESULTING CONDUIT SIZE. REFERENCE THE the main panel is controlled electronically. Refer to C. TOTAL AC SIZE OF POWERWALLS: 0 KW manufacturer's instructions for more information." D. TOTAL AC SIZE OF SYSTEM (B+C): 11.4 KW 'WIRE & CONDUIT SIZE EQUIVALENCE TABLE' ATTACHED Voc* = MAX VOC AT MIN TEMP E. TOTAL DC SIZE OF PV: 14.4 KW TO THE PLANSET. GD Please see MCI wiring detail page for more information POI (2)Gr qd RoQ (1)AWG/B, 1HWN-2, Block -(1)AWG 18, THWN-2, White —(2)Tesla Tesla 4J 4-String Combiner Box D� 5/8 x 8, Copper © AC _ (2)PV Wire, AWG 10 Voc* =315.42 VDC Isc =11.14 ADC A g oPP (1)AWG/8, THWN-2, Red (1)AWG /6, Solid Bore Copper EGC Vmp =222.78VDC Imp=10.77 ADC UNFUSED, GROUNDED, Black, Diag DIN Roil with Bracket/Cord Grip Z (1)1 Backup Switch (1)AWG/10, 1HWN-2, Green EGC Vmp =240 VAC Imp=32 Mt_ O PV (13)Tesla MCI, 650V, 12A Backup Switch -(1 Conduit Kit; 3/4- EMT -(1)Eaton 204 MS68 (1)AWG#10, THWN-2, Block (1)AWG I8, THWN-2, Block Voc* =315.42 VDC Isc =22.28 ADC _ B-Line Meter Socket, 200A, AW Hub top, Overhead, 4 jaws, Ring type G (1)AWG #6, Solid Bare Copper -(3)ILSCO IPC 4/0-2/0 v(1)AWG 110, THWN-2, Red ©�(1)AWG#8, THWN-2, Red Vmp =222.78VDC Imp=21.54 ADC nd Insulation Piercing Connector; Main 4/0-2, Tap 2/0-6 (1)AWG 1,10, 1HWN-2, Green EGC Vmp =240 VAC Imp=16 MC ���111 (1)AWG/10, THHN/THWN-2, Green EGC-(1)Conduit Kit; 3/4" EMT -(1)Ground Rod; 5/8" x 8', Copper y —(1)CUTLER-HAMMER DS36FK (1 Conduit Kit; 3/4" EMT (1)AWG 110, THWN-2, Black Voc* =315.42 VDC Isc =11.14 ADC (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL Fuse Kit; Class (3 AwG /2/0, NMl-2rBlack O k(1)AWG /10, 1HWN-2, Red Vmp =222.78VDC Imp=10.77 ADC ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE -(2)FERRAZ SHAWMUT#11270R ©�(1)AWG /4, THWN-2, Green Fuse: 70A 250V. Class RKS (1)AWG ITO, THHN/THWN-2, Green EGC-(1)Conduit Kit 3/4" EMT -(1)CUTLER-HAMMER !DG100NB (1)C2pdPit /N K2 PVC; Schedule 80 (2)PV tWre AWG 10 Voc* =525.71 VDC Isc =11.14 ADC Ground/Neutral IME Kit; A General Duty(DG) (t)AWG g10, THWN-2, Black Voc* =525.71 VDC Isc =11.14 ADC 1 (1)AWG/6, Solid Bare Copper EGC Vmp =371.3 VDC Imp=10.77 ADC -(1)CUTLER-HAMMERDG223NRB I (1)AWG /4, 1HWN-2, White Disconnect; 100A, 240Vac, Fushle, NEMA 3R ; Ir �(1)AWG #4, THWN-2, Red ®�(1)AWG /10, THWN-2, Red Vmp =371.3 VDC Imp=10.77 ADC X I—(1)SQUARE D /H0M1224L125PC L (1)AWG /4, THWN-2, Black IIL�LLL(1 AWG #10, THHN/THWN-k Green EGC.-(1)Conduit.Kit 3/4" EMT (2)pV YWre, AWG 10 Voc* -315.42 VDC Isc =11.14 ADC (t AWG 110, THWN-2, Black Voc -315.42 VDC Isc =11.14 ADC Load Center; 125A Convertible,NETk1A1,12sp/24cir,12Ov/240v,Combo Cover -(1 AWG THWN-2, Green -(1)Conduit Kit; 1-1 4" EMT (� �' (1)AWG#6, Solid Bare Copper EGC Vmp =222.78VDC Imp=10.77 ADC -(1)SQUARE D H0M250 ( ) / O (1)AWG i10, THWN-2, Red Vmp =222.78VDC Imp=10.77 ADC Breaker; A 2P, 2 (1 AWG/4, THWN-2, White (1)AWG 0 THHN WN-2, Green EGC-(1)Conduit Kit; 3 4 EMT Spaces ©�[ ( ) /t , /TM ( ) / " -(1)SQUARE D !H 220 r(1)AWG /4, NWN-2, Red (4)PV Mire, AWG 10 Voc* =315.42 VDC Isc =11.14 ADC Breaker; A , 2 Spaces (1)AWG /4, THWN-2, Block (1)AWG�10, THWN-2, Black Voc* =105.14 VDC Isc =11.14 ADC O li(1)AWG#6, Solid Bare Copper EGC Vmp =222.78VDC Imp=10.77 ADC -(1)AWG �, Solid Bore Copper -(1)Conduit Kit; 1" EMT ® (1)AWG /10, THWN-2, Red Vmp =74.26 VDC Imp=10.77 ADC W I—(1)UL 508 Emergency Stop Device - NEMA 4X (1)AWG/10, THHN/THWN-2, Green EGC-(1)Conduit Kit; 3/4" EMT rrf�(2)PV Wire, AWG = = ®Is (1)AWG /6, Solid Bare10 Copper EGC VmpVoc* =74.26105.14 VDC VDC IIscmp-10.7711.14 ADC ADC SHALL NOT BE BE USED U FOR THE J B-0103397 00 DESC 1Ul: DESIGN: CONTAINED S CONFIDENTIAL- THE IN HEREIN loe NUMBE>z vikram sood 14.4 KW PV ARRAY Usman Ali Iftikhar T . JI L. n ED BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Metal-Flashing 329 Rocky Hill Rd 13.5 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: Northampton, MA 01062 THE SALE AND USE OF THE RESPECTIVE (36) Tesla # T400H TESLA EQUIPMENT, WITHOUT THE WRITTEN NVFRTER: PAGE NAME: SHEET: REM DATE PERMISSION OF TESLA INC. 4134274757 Multiple Inverters THREE LINE DIAGRAM 5 8/12/2022 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY - Address: 329 Rocky Hill Rd INVERTER INVERTER 4113/4 ENERGY STORAGE .411111. SYSTEM RAPID •`�` ® SHUTDOWN SWITCH 3 AC DISCONNECT UTILITY SERVICE OPERATING VOLTAGE = 240V JB-0103397-00 J B-010 3 39 7 0 0 CUSTOMER: DESORPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN J08 NUMBER: _ CONTAINED SHALL NOT BE USED FOR THE vikram sood 14.4 KW PV ARRAY Usman Ali Iftikhar T 77. 5 L n BENEFIT OF ANYONE EXCEPT TESTA INC., NOR MOUNTING SYSTEM SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Metal—Flashing 329 Rocky Hill Rd 13.5 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE NE RECIPIENTS MODULES: Northampton MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH r THE SALE AND USE OF THE RESPECnh (36) Tesla # T400H SHEET: REV DATE TESLA EQUIPMENT, WITHOUT THE WRITTEN mi:R/E� PAGE NAME: PERMISSION OF TESLA INC. Multiple Inverters 4134274757 SITE PLAN PLACARD 6 8/12/2022 WARNING:PHOTOVOLTAIC POWER SOURCE Label Location: Label Location: Label Location: (C)(CB)(JB) WARNING (AC)(POI) WARNING (DC) (INV) Per Code: Per Code: NEC 690.31.G.3 ELECTRIC SHOCK HAZARD NEC 69013E ELECTRIC SHOCK HAZARD . . DO NOT TOUCH TERMINALS THE DC CONDUCTORS OF THIS Label Location: TERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM ARE PHOTOVOLTAIC DC (DC) (INV) LOAD SIDES MAY BE ENERGIZED UNGROUNDED AND IN THE OPEN POSITION MAY BE ENERGIZED DISCONNECT Per Code: NEC 690.13.B Label Location: Label Location: MAXIMUM VOLTAGE Label Location: WARNING (POI) SOLAR PV SYSTEM ABB/Delta Solivia Inverter - (DC) (INV) Per Code: EQUIPPED WITH RAPID Per Code: MAXIMUM CIRCUIT CURRENT INVERTER OUTPUT b Per Code: CONNECTION NEC 705.12.B.2.3.b SHUTDOWN 690.56(C)(1)( ) MAX RATED OUTPUT CURRENT NEC 690.53 DO NOT RELOCATE TURN RAPID OF THE CHARGE CONTROLLER THIS OVERCURRENT SHUTDOWN SWITCH ■ OR DC-TO-DC CONVERTER POSITION DEVICE TOTHE'OFF' O SHUT (IF INSTALLED) DOWN CONDUCTORS OUTSIDE THE ARRAY _ _ CONDUCTORS WITHIN THE ARRAY REMAIN Label Location: ENERGIZED IN SUNUGHT Label Location: (INV) WARNING (DC) (INV) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID Per Code: Per Code: SHUTDOWN ELECTRIC SHOCK HAZARD NEC 690.56.C.3 Label Location: IF A GROUND FAULT IS INDICATED 690.41.B RAPID' NORMALLY GROUNDED EQUIPPED WITH RAPIDYSTEM ; ' SolarEdge and,Delta M-Series and,Telsa Inverter CONDUCTORS MAY BE �p� Per Code: UNGROUNDED AND ENERGIZED $WN 690.56(C)(1)(a) Label Location: TURN RAMO CAUTION (D) (POI) SNITCH TO THE SOLAR Per Code: *OFF•POSmONTO Label Location: PHOTOVOLTAIC SYSTEM fpvilECTAICpiviris' WARNING (DC) (CB) CIRCUIT IS BACKFEDNEC 690.64.B.4MTh AND REDUCE Per CodeIO ELECTRICAL SHOCK HAZARC N THE ARRAY. DO NOT TOUCH TERMINALS CEC 690.13.E - TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED Label Location: IN THE OPEN POSITION DC VOLTAGE IS CAUTION (P01) ALWAYS PRESENT WHEN DUAL POWER SOURCE Per Code: SOLAR MODULES ARE SECOND SOURCE IS NEC 705.12.6.3 EXPOSED TO SUNLIGHT PHOTOVOLTAIC SYSTEM Label Location: Label Location: PHOTOVOLTAIC AC (AC) (P01) PHOTOVOLTAIC POINT OF (P01) INTERCONNECTION DISCONNECT Per Code: Per Code: WARNING. ELECTRIC SHOCK CEC 690.13.B (AC): AC Disconnect NEC 690.13.E HAZARD DO NOT TOUCH (C): Conduit TERMINALS.TERMINALS ON BOTH THE LINE AND LOAD SIDE (CB): Combiner Box MAY BE ENERGIZED IN THE OPEN (D): Distribution Panel POSITION. FOR SERVICE (DC): DC Disconnect Label Location: DE-ENERGIZE BOTH SOURCE MAXIMUM AC (AC) (P01) AND MAIN BREAKER. (IC): Interior Run Conduit OPERATING CURRENT Per Code: PV POWER SOURCE (INV): Inverter With Integrated DC Disconnect MAXIMUMMAXIMUM AC V NEC 690.54 OPERATING CURRENT A (LC): Load Center OPERATING VOLTAGE _ MAXIMUM AC (M): Utility Meter OPERATING VOLTAGE _ V (P01): Point of Interconnection Label Set Label Location: Label Location: BACKUP LOAD CENTER (BLC) CAUTION (MSP) Per Code: TRI POWER SOURCE Per Code: NEC 408.4 SECOND SOURCE IS PHOTOVOLTAIC SYSTEM NEC 705.12(B)(3) THIRD SOURCE IS ENERGY STORAGE SYSTEM Label Location: CAUTION (BLC) DO NOT ADD NEW LOADS Per Code: Label Location: NEC 220 WARNING (MSP) Per Code: THIS EQUIPMENT FED BY NEC 705.12.6.2.3.c Label Location: MULTIPLE SOURCES.TOTAL RATING OF ALL OVER CURRENT CAUTION (MSP) DEVICES EXCLUDING MAIN THIS PANEL HAS SPLICED FEED- Per Code: SUPPLY OVERCURRENT DEVICE, THROUGH CONDUCTORS. NEC 312.8.A(3) SHALL NOT EXCEED AMPACITY LOCATION OF DISCONNECT AT ENERGY OF BUSBAR. STORAGE BACKUP LOAD PANEL NOMINAL ESS VOLTAGE 12(Y240V Label Location: Label Location: (MSP) CAUTION (MSP) MAX AVAILABLE SHORT- Per Code: DUAL POWER SOURCE Per Code: CIRCUIT FROM ESS 32A- Per 706.7(D) label to be marked in field SECOND SOURCE IS NEC 705.12(B)(3) ARC FAULT CLEARING ENERGY STORAGE SYSTEM TIME FROM ESS 6/ms DATE OF CALCULATION Label Location: ENERGY STORAGE SYSTEM ON SITE (MSP) LOCATED WITHIN LINE OF SIGHT Per Code: Label Location: ENERGY STORAGE SYSTEM ON SITE (MSP) LOCATED ON ADJACENT WALL Per Code: Label Location: ENERGY STORAGE SYSTEM ON SITE (MSP) LOCATED ON OPPOSITE WALL Per Code: Label Location: ENERGY STORAGE SYSTEM ON SITE (MSP) LOCATED INSIDE Per Code: (AC): AC Disconnect (BLC): Backup Load Center (MSP): Main Service Panel Label Set QG0MP4Tj6 ti� � ROOFING SYSTEM SPECIFICATIONS r�A®,4 GROUND ZEP LEVELING FOOT OOMPP�� Listed to UL 2703 Listed to UL 2703 DESCRIPTION PV mounting solution for composition shingle roofs Part#850-1511 Part#850-1397 1 Works with all Zep Compatible Modules y , Auto bonding UL-listed hardware creates structural and electrical bond „� r �Q SPECIFICATIONS Designed for pitched roofs Installs in portrait and landscape orientations DC WIRE CLIP HOME RUN CLIP Engineered for spans up to 72"and cantilevers up to 24" Listed to UL 1565 Listed to UL 1565 Part#850-1509 Part#850-1510 ZS Comp has a UL 1703 Class"A" Fire Rating when installed using modules from any ! ti manufacturer certified as"Type 1"or"Type 2" Attachment method UL listed to UL 2582 for Wind Driven Rain edr ��� �rII0 1,ZS Comp supports 50 psf(2400 Pa)front and up to 72 psf(3450 Pa) rear side design load rating for Portrait module orientation per UL 2703. ZS Comp supports 50 psf(2400 Pa)front side and up to 72 psf(3450 Pa) rear side design ARRAY SKIRT END CAP load rating for Landscape module orientation. Listed to UL 2703 Listed to UL 2703 Engineered for compliance with ASCE 7-05, 7-10, and 7-16 wind load requirements Part#850-1608 Part#850-1586(Left) Part#850-1588(Right) i� Zep wire management products listed to UL 1565 for wire positioning devices ,I0I44rlt \I 6,� ZS Comp grounding products are listed to UL 2703 and UL 467 "1 ZS Comp bonding products are listed to UL 2703 MOUNTING BLOCK FLASHING ACCESSORY SKIRT GRIP INTERLOCK Listed to UL 2703 Listed to UL 2703 and UL 2582 for Wind Driven Rain Listed to UL 2703 Listed to UL 2703 Part#850-1633 Part#850-1634 Part#850-1606 Part#850-1613 °milf' 0. / 0 _____7 0 -.. 0114) CI ® (rap"' .j CAPTURED WASHER LAG HYBRID INTERLOCK Part#850-1631-002 and#850-1631-004 Listed to UL 2703 Part#850-1281 i .•,' 1,4 --!;"...001Gi/ i ZS COMP DATASHEET 3 Ta" SLn CC WR \ C DH A CE \ EAL \ OTES • DRAWING OF STANDARD MCI WIRING DETAIL FOR ANY GIVEN STRING LENGTH • IF INITIATED, RAPID SHUTDOWN OCCURS WITHIN 30 G D SECONDS OF ACTIVATION AND LIMITS VOLTAGE ON THE ROOF TO NO GREATER THAN 165V (690.12.B.2.1) • MID CIRCUIT INTERRUPTER (MCI) IS A UL 1741 PVRSE CERTIFIED RAPID SHUTDOWN DEVICE (RSD) n DC+ J—BOX J—BOX J—BOX J—BOX J—BOX J—BOX MCI MCI DC- -� T------ ___, ETROE T 'JV VOLES U • MCIS ARE LOCATED AT ROOF LEVEL, JUST UNDER THE PV MODULES IN ACCORDANCE WITH 690.12 REQUIREMENTS 1 • THE QUANTITY OF MCIS PER STRING IS DETERMINED BY STRING LENGTH - - NUMBER OF MODULES BETWEEN MCI UNITS = 0-3 — MAXIMUM NUMBER OF MODULES PER MCI UNIT = 3 J—BOX J—BOX J—BOX J—BOX — MINIMUM NUMBER MCI UNITS = MODULE COUNT/3 " . Mcl T L / / *Exception: Tesla (Longi) modules installed in locations where the max Voc for 3 modules at low design temperature exceeds 165V shall be limited to 2 modules between MCIs. PLEASE REFER TO MCI CUTSHEET AND PVRSA INSERT FOR © (2)AWG, PV Wire, 600V, Black DC MORE INFORMATION T = 55 L n VC WR \ C DH A CE \ - AL \ OTIS • DRAWING OF STANDARD MCI WIRING DETAIL FOR ANY GIVEN STRING LENGTH - • IF INITIATED, RAPID SHUTDOWN OCCURS WITHIN 30-- - SECONDS OF ACTIVATION AND LIMITS VOLTAGE ON THE ROOF TO NO GREATER THAN 165V (690.12.B.2.1 ) GD • MID CIRCUIT INTERRUPTER (MCI) IS A UL 1741 PVRSE CERTIFIED RAPID SHUTDOWN DEVICE (RSD) CDC+ (DIODE DC- • DIODE DIODE DIODE DIODE DIODE DIODE SOLAR POOP I HS MCI • MCIS ARE LOCATED AT DECK LEVEL, JUST UNDER THE jp. DIODE DIODE DIODE MCI DIODE DIODE DIODE DIODE TILES IN ACCORDANCE WITH 690.12 REQUIREMENTS . L- • THE QUANTITY OF MCIS PER STRING IS DETERMINED BY STRING LENGTH - NUMBER OF TILES BETWEEN MCI UNITS = 0-10 DIODE DIODE DIODE DIODE DIODE DIODE DIODE MCI - MAXIMUM NUMBER OF TILES PER MCI UNIT = 10 , - MINIMUM NUMBER MCI UNITS = TILE COUNT/10 DIODE DIODE DIODE DIODE / / PLEASE REFER TO MCI CUTSHEET AND PVRSA INSERT FOR �i MORE INFORMATION Jfl- (2)Awc, PV Wire, 600V, Black IDC 114, i, ,.fit- /''�1 >� e _-. ' 4 -• SOLAR INVERTER • , j 2 - 7� _ - #qk S Tesla Solar Inverter provides DC to AC conversion and integrates with the Tesla ecosystem, including Solar Panels,Solar Roof,Powerwall,and vehicle charging,to provide a seamless T s s c a sustainable energy experience. KEY FEATURES Integrated rapid shutdown,arc • 2x the standard number of MPPTs for fault,and ground fault protection high production on complex roofs • . • No neutral wire simplifies installation I ` ; ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS MODEL NUMBER 1534000-xx-y 1538000-xx-y Dimensions 660 mm x 411 mm x 158 mm(26 in x 16 in x 6 in) OUTPUT(AC) 3.8 kW 7.6 kW Weight 52lb" Nominal Power 3,800 W 7,600 W Mounting options Wall mount(bracket) Maximum Apparent Power 3,328 VA at 208 V 6,656 VA at 208 V ^Door and bracket can be removed for a mounting weight of 37 lb. } 3,840 VA at 240 V 7,680 VA at 240 V 1 S Maximum Continuous Current 16 A 32 A o0 oo _...___.. ... ..._ _. co Breaker(Overcurrent Protection) 20 A 40 A _ oOM 0 Nominal Power Factor 1 _0.9(leading/lagging) 4 g'IL R OM 00 00 ' THD(at Nominal Power) <5% oo e moo HEI 4, ��A INPUT(DC) 660 �=�0o0 ' mm - o0 �� MPPT 2 4 pI ' • Input Connectors per MPPT 1-2 1-2-1-2 Maximum Input Voltage 600 VDC .,. DC Input Voltage Range 60-550 VDC I — DC MPPT Voltage Range 60-480 VDC' . . . .., . . y., __. . . . Maximum Current per MPPT(I,,,•) 13 A2 ,__ , .. i -411 mm-- ,f 158H Maximum Short Circuit i mm 17 AZ Current per MPPT(I,) T = SLII ENVIRONMENTAL SPECIFICATIONS PERFORMANCE SPECIFICATIONS Operating Temperature -30°C to 45°C(-22°F to 113°F)5 Peak Efficiency 98%at 208 V 98.4%at 208 V Operating Humidity(RH) Up to 100%,condensing 98.1%at 240 V 98.6%at 240 V Storage Temperature -30°C to 70°C(-22°F to 158°F) SOLAR INVERTER CEC Efficiency 97.5%at 208 V 97.5%at 208 V 97.5%at 240 V 98.0%at 240 V Maximum Elevation 3000 m(9843 ft) Allowable DC/AC Ratio 1.7 Environment Indoor and outdoor rated 3.8 kW 17.6 kW Customer Interface Tesla Mobile App Enclosure Rating Type 3R Tesla Solar Inverter completes the Tesla home solar system,converting DC power from solar to AC power for home consumption.Tesla's Internet Connectivity Wi-Fi(2.4 GHz,802.11 b/g 3n). Ingress Rating IP55(Wiring compartment) Ethernet,Cellular(LTE/4G) Pollution Rating PD2 for power electronics and terminal wiring renowned expertise in power electronics has been combined with robust safety features and a simple installation process to produce an AC Remote Metering Support Wi-Fi(2.4 GHz,802.11 b/g/n), compartment.PD3 for all other components outstanding solar inverter that is compatible with both Solar Roof and traditional solar panels.Once installed,homeowners use the Tesla RS-485 mobile app to manage their solar system and monitor energy consumption,resulting in a truly unique ecosystem experience. Operating Noise @ 1 m <40 db(A)nominal,<50 db(A)maximum Protections Integrated arc fault circuit interrupter (AFC1),Rapid Shutdown s For the 7.6 kW Solar Inverter,performance may be de-rated to 6.2 kW at KEY FEATURES 240 V or 5.37 kW at 208 V when operating at temperatures greater than Supported Grid Types 60 Hz,240 V Split Phase 45°C • Built on Powerwall 2 technology for • Designed to integrate with Tesla Powerwall and Tesla App 60 Hz.208 V Wye exceptional efficiency and reliability • 3.8 kW and 7.6 kW models available 'Maximum current. COMPLIANCE INFORMATION 'Where the DC input current exceeds an MPPT rating,jumpers can be used to • Wi-Fl,Ethernet,and cellular connectivity allow a single MPPT to intake additional DC current up to 26 AL,/34 A I,. Grid Certifications UL 1741,UL 1741 SA,IEEE 1547,IEEE 1547.1 with easy over-the-air updates `Cellular connectivity subject to network operator service coverage and signal Safety Certifications UL 1741 PVRSS.UL 16996,UL 1998(US),UL 3741 strength. Emissions EN 61000-6-3(Residential),FCC 47CFR15.109(a) -7- L. = TESLA.COM/ENERGY SOLAR SHUTDOWN DEVICE The Tesla Solar Shutdowrt.[2eviceis aMid-Circuit Interrupter(MCI) -�f r /7/�-�%io and is part of the PV system rapid shutdown(RSD)function in —��`'•'i f/ �(. accordance with Article 690 of the applicable NEC.When paired C•... •N3 with the Tesla Solar Inverter,solar array shutdown is initiated by any , loss of AC power. ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS Model Number MCI-1 Electrical Connections MC4 Connector Nominal Input DC Current Rating(IMP) 12 A Maximum Input Short Circuit Current(Ix) 15 A Housing Plastic Maximum System Voltage 600 V DC Dimensions 125 mm x 150 mm x 22 mm (5 in x 6 in x 1 in) Weight 350 g(0.77 lb) Mounting Options ZEP Home Run Clip RSD MODULE PERFORMANCE M4 Screw(#10) M8 Bolt(5/16") Maximum Number of Devices per String 5 Nail/Wood screw Control Power Line Excitation Passive State Normally open t 0 Maximum Power Consumption 7 W 4 250 mm Warranty 25 years ° M4 Screw COMPLIANCE INFORMATION {� 650 mm 150 mm M8 Bolt Certifications UL 1741 PVRSE,UL 3741, �7 PVRSA(Photovoltaic Rapid Shutdown Array) Jr Nail/ RSD Initiation Method PV System AC Breaker or Switch MINI„I _�. Wood Screw Compatible Equipment See Compatibility Table below -- .1V: i ENVIRONMENTAL SPECIFICATIONS ' Ambient Temperature -40°C to 50°C(-40°F to 122°F) 22 -1— 125 mm —0' Storage Temperature -30°C to 70°C(-22°F to 158°F) Enclosure Rating NEMA 4/IP65 UL 3741 PV HAZARD CONTROL (AND PVRSA) COMPATIBILITY Tesla Solar Roof and Tesla/Zep ZS Arrays using the following modules are certified to UL 3741 and UL 1741 PVRSA when installed with the Tesla Solar Inverter and Solar Shutdown Devices.See the Tesla Solar Inverter Installation Manual for detailed instructions and for guidance on installing Tesla Solar Inverter and Solar Shutdown Devices with other modules. Brand Model Required Solar Shutdown Devices Tesla Solar Roof V3 1 Solar Shutdown Device per 10 modules Tesla Tesla TxxxS(where xxx=405 to 450 W.increments of 5) 1 Solar Shutdown Device per 3 modules' Tesla Tesla TxxxH(where xxx=395 to 415 W,increments of 5) 1 Solar Shutdown Device per 3 modules Hanwha Q.PEAK DUO BLK-G5 1 Solar Shutdown Device per 3 modules Hanwha Q.PEAK DUO BLK-G6+ 1 Solar Shutdown Device per 3 modules 'Exception:Tesla solar modules installed in locations where the max Voc for three modules at low design temperatures exceeds 165 V shall be limited to two modules between Solar Shutdown Devices. T '_ff Ei t- n ; TESLA.COM/ENERGY BACKUP SWITCH ,k The Tesla Backup Switch controls connection to the grid in a Powerwall system, and can be easily installed behind the utility meter or in a standalone meter panel downstream of the utility meter. The Backup Switch automatically detects grid outages,providing a seamless transition to backup power. It communicates directly with Powerwall, allowing home energy usage monitoring from any mobile device with the Tesla app. PERFORMANCE SPECIFICATIONS 176 mm Model Number 1624171-xx-y Continuous Load Rating 200A,120/240V Split phase Short Circuit Current Rating 22 kA with breaker' r-----* Communication CAN Product Compatibility Powerwall 2 with Backup Gateway 2, r71:::-TOP Powerwall+ III Expected Service Life 21 years MID Warranty 10 years I'Breaker size must he equal to or greater than the available fault current. 205 min ��,;,_II�� I COMPLIANCE INFORMATION � �_ _ al �klIh11Illlllfill jam. Safety Standards USA:UL 414,UL 2735,UL 916 CA Prop 65 Emissions FCC,ICES i ENVIRONMENTAL SPECIFICATIONS Operating Temperature -40°C to 50°C(-40°F to 122°F) Storage Temperature -40°C to 85°C(-40°F to 185°F) Enclosure Rating NEMA 3R ;I Pollution Rating PD3 ' MECHANICAL SPECIFICATIONS lwat Dimensions 176 mm x 205 mm x 74 mm Iel (6.9 in x 8.1 in x 2.9 in) Weight 2.8 lbs Meter and Socket Compatibility ANSI Type 2S,ringless or ring type External Service Interface Contactor manual override2 Reset button 74 mm - Conduit Compatibility 1/2-inch NPT Manually overrides the contactor position during a service event. ry , ., _. TESLA.COM/ENERGY POWERWALL+ PHOTOVOLTAIC (PV) AND BATTERY ENERGY MECHANICAL SPECIFICATIONS 4- STORAGE SYSTEM (BESS) SPECIFICATIONS r, Dimensions 1596 x 755 x 160 mm(62.8 x 29.7 x 6.3 in) Powerwall+Model Number 1850000-xx-y Total Weight 140 kg(310 Ib)' Solar Assembly Model Number 1538000-xx-y Battery Assembly 118 kg(261 Ib) ' Nominal Battery Energy 13.5 kWh Solar Assembly 22 kg(49 Ib) r Nominal G'd Voltage(Input/Output) 120/240 VAC Mounting options Floor or wall mount Grid Voltage Range 211.2-264 VAC 755 mm 160 m_mI r Frequency 60 Hz r I 1. "I� . Phase 240 VAC 2W+N+GND ` Maximum Continuous Power On-Grid 7.6 kVA full sun/5.8 kVA no sun' , ' Maximum Continuous Power Off-Grid 9.6 kW full sun/7 kW no sun' • Peak Off-Grid Power(10 s) 22 kW full sun/10 kW no sun' p Maximum Continuous Current On-Grid 32 A output s € T S L Maximum Continuous Current Off-Grid 40 A output Load Start Capability 98-118 A LRA2 T = S L n •;: PV Maximum Input Voltage 600 VDC 1596 mm PV DC Input Voltage Range 60-550 VDC PV DC MPPT Voltage Range 60-480 VDC ' MPPT5 4 Input Connectors per MPPT 1-2-1-2 i Maximum Current per MPPT(I ) 13 A; � Maximum Short Circuit 17 A; • Current per MPPT(Id Allowable DC/AC Ratio 1.7 Overcurrent Protection Device 50Abreaker ENVIRONMENTAL SPECIFICATIONS Maximum Supply Fault Current 10 kA Output Power Factor Rating +/-0.9 to 1' Operating Temperature -20°C to 50°C(-4°F to 122°F)' �' Round Trip Efficiency 90%5 • Recommended Temperature 0°C to 30°C(32°F to 86°F) ,, -. ,. ?` -. . • Solar Generation CEC Efficiency 97.5%at 208 V il Operating Humidity(RH) Up to 100%,condensing 98.0%at 240 V Storage Conditions -20°C to 30°C(-4°F to 86°F) Customer Interface Tesla Mobile App Up to 95%RH,non condensing State of Energy(SoE):25%initial POWERWALL+ Internet Connectivity Wi-Fi,Ethernet.Cellular LTE/4G)6 Maximum Elevation 3000 m(9843 ft) PV AC Metering Revenue grade(+/-0.5%) Environment Indoor and outdoor rated Protections Integrated arc fault circuit interrupter(AFCI), Enclosure Type Type 3R Powerwall+is an integrated solar battery system that stores energy from solar production. Powerwall+has two PV Rapid Shutdown Solar Assembly Ingress Rating IP55(Wiring Compartment) separate inverters, one for battery and one for solar,that are optimized to work together. Its integrated design and Warranty 10 years Battery Assembly Ingress Rating lP56(Wiring Compartment) streamlined installation allow for simple connection to any home,and improved surge power capability brings whole IP67(Battery&Power Electronics) home backup in a smaller package. Smart system controls enable owners to customize system behavior to suit their Noise Level @ 1 m <40 db(A)optimal, renewable energy needs. COMPLIANCE INFORMATION <50 db(A)maximum 'Values provided for 25°C(77°F). PV Certifications UL 1699B,UL 1741,UL 3741,UL 1741 SA,UL Load start capability may vary. KEY FEATURES 1998(US).IEEE 1547,IEEE 1547.1 'Where the DC input current exceeds an MPPT rating,jumpers can be used to Battery Energy Storage UL 1642,UL 1741,UL 1741 PCS,UL 1741 SA,UL allow a single MPPT to intake additional DC current up to 26 A imp/34 A I . • Integrated battery, inverter,and system controller for a more compact install System Certifications 1973,UL 9540,IEEE 1547,IEEE 1547.1,UN 38.3 'Power factor rating at max real power. K 'AC to battery to AC,at beginning of life. • A suite of application modes, including self-powered, time-based control,and backup modes Grid Connection United States 'Cellular connectivity subject to network service coverage and signal • Wi-Fi, Ethernet,and LTE connectivity with easy over-the-air updates Emissions FCC Part 15 Class B strength. 'The total weight does not include the Powerwall+bracket,which weighs an Environmental RoHS Directive 2011/65/EU additional 9 kg(20 Ib). Seismic AC156,IEEE 693-2005(high) 'Performance may be de-rated at operating temperatures below 10°C(50°F) or greater than 43°C(109°F). r`-- -- I, °. .. ,• - TESLA.COM/ENERGY SOLAR SHUTDOWN DEVICE SYSTEM LAYOUTS The Tesla Solar Shutdown Device is a Mid-Circuit ''— Powerwall+with Backup Switch Installed Behind Utility Meter Interrupter(MCI)and is part of the PV system rapid -( ,—,.............;;,... '"'" \ / shutdown(RSD)function in accordance with Article 690 - (_-I of the applicable NEC. When paired with Powerwall+, ` _____,' solar array shutdown is initiated by pushing the System ` VII Shutdown Switch if one is present. Solar Backup Switch I___ ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS =— • Model Number MCI-1 Electrical Connections • ,MC4 Connector Nominal Input DC Current Rating(Imp) 12 A -r =s L ^ _ Maximum Input Short Circuit Current(Ix) 15 A Housing Plastic Load center Meter socket panel Grid Maximum System Voltage 600 V DC Dimensions 125 mm x 150 min x 22 min (5 in x 6 in x 1 in) Weight 350 g(0.77 lb) RSD MODULE PERFORMANCE • Mounting Options ZEP Home Run Clip — — - M4 Screw(#10) Powerwall+ Backup loads Maximum Number of Devices per String 5 M8 Bolt(5/16") Control Power Line Excitation Nail/Wood screw Passive State Normally open Maximum Power Consumption 7 W 0 Warranty 25 years Power%wall+with Backup Switch Installed Downstream of Utility Meter 250 mm __4 COMPLIANCE INFORMATION ��/// /1 M4 Screw // j o e Certifications UL 1741 PURSE,UL 3741, PVRSA(Photovoltaic Rapid fl Solar 150 min M8 Bolt Backup Switch Utility Meter Shutdown Array) 650 min I RSD Initiation Method External System Shutdown Switch 0 O Compatible Equipment See Compatibility Table below + =MI ill Nail/ L. T — "'I Wood Screw -- ENVIRONMENTAL SPECIFICATIONS == == _"- -___ T -s, Load Center Meter socket panel Meter socket panel Grid Ambient Temperature -40°C to 50°C(-40°F to 122°F) Storage Temperature -30°C to 60°C(-22°F to 140°F) Enclosure Rating NEMA 4/IP65 1— ,..-;') 1 4-- 125 mm \ Q_ 22mm I — — Powerwall+ Backup loads UL 3741 PV HAZARD CONTROL (AND PVRSA) COMPATIBILITY Tesla Solar Roof and Tesla/Zep ZS Arrays using the following modules are certified to UL 3741 and UL 1741 PVRSA when installed with the Powerwall+and Solar Shutdown Devices.See the Powerwall+Installation Manual for detailed instructions and for guidance on installing Powerwall+and Solar Shutdown Devices with other modules. Brand Model Required Solar Shutdown Devices Tesla Solar Roof V3 1 Solar Shutdown Device per 10 modules Tesla Tesla TxxxS(where xxx=405 to 450 W.increments of 5) 1 Solar Shutdown Device per 3 modules' Tesla Tesla TxxxH(where xxx=395 to 415 W,increments of 5) 1 Solar Shutdown Device per 3 modules Hanwha Q.PEAK DUO BLK-G5 1 Solar Shutdown Device per 3 modules Hanwha Q.PEAK DUO BLK-G6+ 1 Solar Shutdown Device per 3 modules 1Exception:Tesla solar modules installed in locations where the max Voc for three modules at low design temperatures exceeds 165 V shall be limited to two modules between Solar Shutdown Devices. TESLA.COM/ENERGY TESLA.COM/ENERGY Powerwall+with Backup Gateway 2 for Whole Home Backup :` MM NM MN Solar 1-/ 1 9 Meter Load center Backup Gateway 2 Meter socket panel --Grid - - I Powerwall+ Backup loads Powerwall+with Backup Gateway 2 for Partial Home Backup —//// Solar r 9 I I......... ,., Meter tz Backup panel Backup Gateway 2 Meter socket panel Grid I Powerwall+ Backup loads == 2 Non-backup panel SSS y Non-essential loads TFSLA.COM/FNERGY Tesla Photovoltaic Module Module Specifications T395H, T400H, and T405H Electrical Characteristics - Power Class T395H T400H T405H The T.%lamodule is one-Of the rnOSt ppwerflil reciriantial phntnvnitair• Test Method STC _ NMOT STC NMOT STC NMOT modules available and exceeds industry engineering and quality standards. N Max Power,P,,ax(W) 395 296.3 400 300.1 405 303.8 Featuring our proprietary Zep Groove design,the all-black module mounts E Open Circuit Voltage,Von(V) 45.27 42.69 45.30 42.72 45.34 42.76 close to your roof for a minimalist aesthetic.Modules are certified to IEC/ E lu Short Circuit Current,Ix(A) 1110 8.95 11.14 8.97 11.17 9.00 UL 61730-1,IEC/UL 61730-2 and IEC 61215. 35 mm/1.378 in Max Power Voltage,V„p(V) 36.88 35.03 37.13 35.25 37.39 35.46 Max Power Current,It,,,(A) 10.71 8.46 10.77 8.51 10.83 8.57 Module Efficiency(%) >_20.1 >_20.4 >_20.6 - - . . . . . . . . STC 1000 W/m',25°C,AM1.5 NOCT 800 W/m',20°C,AM1,5,wind speed 1 m/s . Mechanical Loading Temperature Rating(STC) Front Side Test Load 6120 Pa 1128 lb/ft' Refer to module and system Temperature Coefficient of Isc +0.04%/°C • Rear Side Test Load 6120 Pa 1128lb/ft' installation manuals for Temperature Coefficient of V., -0.27%/°C allowable design loads,foot - - _ ' : ' •• . Front Side Design Load 4080 Pa 185 lb/ft'• spacings,and cantilever Temperature Coefficient of P (W) -0.34%/°C . . . . . . - . . . . Rear Side Design Load 4080 Pa I 85 lb/ft2 specifications. Hail Test 35 mm at 27.2.m/s 1046 mm 1 41.2 in . 40+/-0.5 mm Mechanical Parameters 1.57+/-0.020 in Cell Orientation 132(6 x 22) ^F F F. llllll! IIIIIlI • . Junction Box IP68,3 diodes Cable 4 mm'112 AWG,1325 mm 147.2 in.Length IIIIIIII III' III. - _ _ _ Connector Staubli MC4 Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass Frame Black Anodized Aluminum Alloy - - Weight 23.5kgI51.8lb_ _ _ _ I n a ',i I.- . , .c c - 1890 mm x 1046 mm x 40 mm E Dimension - E d 74.4 in x 41.2 in x1.57 in Operation Parameters E E M 0 0 Operational Temperature -40°C up to+85°C o, u _ • . - Power Output Tolerance -0/+5 W . . Voc&I,c Tolerance +/-5% • Max System Voltage DC 1000 V(IEC/UL) ° ° . • - - Max Series Fuse Rating 20 A . . . . - . . :. . . . . NOCT 45.7+/-3°C . . . . . . . . ' . Safety Class Class II di- . f i Fire Rating UL 61730 Type 2 Linear Power Warranty . - - . - -.- Materials and Processing 25 years "" Extra Linear Power Output 25 years as I . . - _ At least 98%of nominal power during first year.Thereafter max.0.5%degradation per a year.At least 93.5%of nominal power up to 10 years.At least 86%of nominal power up • to 25 years. . .' .- ° s ,o s ro 25 IV Curves - - Current vs.Voltage Power vs.Voltage Current vs.Voltage . •• .,'-4-'4 i j.^_. 12 Cell rasp=25K 450 cell iem0=25•C tn<Ment lnaalance= . - '2 1000 W/m• 400 . • ,� Fii 10 350 io .Cell lenp=25C . -'000 AVM, ',000 W/m' • B BOO WinV 300 Boo W/m' a Cell Temp=35K 600 W/m' 3 250 - 500 WA,. CNI Temp=aSK 5 400 W/m' - 200 MO Whn' c Cell lamp=55•C 200 W/m• a 150 200 WA, a CNI Temp-65•C 4 O u Cell Temp=)SK u . 00 0 2 0 10 1. 30 40 50 C , 20 30 40 50 0 10 20 30 40 50 Voltage(V) Voltage(V) Voltage(V) Tesla Module t)atasheet T = 5 i n 1 Osla Module Dalasheet 1 = .- - .-, (TEPV-DS-0011-21) (TEPV-DS-001T-21) PV HAZARD CONTROL SYSTEM 1 ZS PVHCS PV HAZARD CONTROL SYSTEM PVHCS I CERTIFICATION UL 3741 REPORT DATE 10-20-21 (APPLICABLE TO ZS COMP, ZS SPAN, ZS RAMP, AND ZS SEAM) UL 3741 REPORT DATE 8-12-21 PV RAPID SHUTDOWN ARRAY, UL 1741 CATEGORY QIJR PV RAPID SHUTDOWN ARRAY, UL 1741 CATEGORY QIJR, REPORT DATE: 2021-06-11 (REV 8-10-21) WARNING:To reduce the risk of injury, read all instructions. WARNING:To reduce the risk of injury, read all instructions. PV HAZARD CONTROL EQUIPMENT AND COMPONENTS PV HAZARD CONTROL EQUIPMENT AND COMPONENTS Function Manufacturer Model No. Firmware Versions Certification Standard Firmware Versions and Checksums Function Manufacturer Model No. and Checksums Certification Standard PVRSE Mid Circuit Tesla MCI-1 N/A UL 1741 PVRSE PVRSE Mid Circuit MCI-1 Interrupter(MCI) N/A UL 1741 PVRSE Interrupter(MCI) Tesla 1550379 7.6 kW:1538000' V4,CEA4F802 UL 1741,1998 7.6 kW:1538000' V4,CEA4F802 Inverter or Powerwall+ Tesla 3.8 kW:1534000' V4,FF7BE4E1 UL 1741,1998 7.6 kW:1850000' V4,CEA4F802 PVRSS/PVRSE Inverter or Powerwall+ Tesla 3.8 kW:1534000' V4,FF7BE4E1 PVRSS/PVRSE 7.6 kW:1850000' V4,CEA4F802 Q.PEAK DUO BLK-G5/SC310-320 PV Module Tesla SR60T1,SR72T1 N/A UL 61730 Hanwha/Q-CELLS Q.PEAK DUO BLK G6+/SC330-345 UL 1703 SR72T2 PV Module N/A Tesla TxxxS (xxx=405 to 450) UL 61730 Diode Harness Tesla Tesla TxxxH(xxx=395 to 415 Tesla SRDTH N/A UL 9703 (Not applicable to SR72T2) PV Wire Jumper(s) Tesla SR-BJ2X,SR-BJ3X, N/A UL 9703 PVHCS Initiator Dedicated PV system AC circuit breaker or AC disconnect switch,labeled per NEC 690.12 N/A SR-BJ4X,SR-BJMini (PV Inverter) requirements. Pass-Through Box Tesla SRPTB-4 N/A UL 1741 PVHCS Initiator Emergency stop device(NISD)-Listed"Emergency Stop Button"or"Emergency Stop UL 508 or UL 60947 Parts PVHCS Initiator: Dedicated PV system AC circuit breaker or AC disconnect switch,labeled per NEC N/A (Powerwall+) Device"or"Emergency Stop Unit". 1,5-1 and 5-5 (PV Inverter) 690.12 requirements. Applies to variations of this part number with suffix of two numbers and one letter. PVHCS Initiator Emergency stop device(NISD)-Listed"Emergency Stop Button"or"Emergency Stop UL 508 or UL 60947 (Powerwall+) Device"or"Emergency Stop Unit" Parts 1,5-1 and 5-5 Note:PVHCS installation requirements may reduce the effective equipment and component ratings below the individual equipment and component 'Applies to variations of this part number with suffix of two numbers and one letter. PVRSE ratings in order to achieve PVHCS shock hazard reduction requirements. Note:PVHCS installation requirements may reduce the effective equipment and component ratings below the individual equipment and component PVHCS INSTALLATION REQUIREMENTS PVRSE ratings in order to achieve PVHCS shock hazard reduction requirements. Max System Voltage 600 VDc PVHCS INSTALLATION REQUIREMENTS PVHCS Maximum Circuit Voltage(Array Internal Voltage After Actuation) 165 VDc(cold weather open circuit) Max System Voltage 600 VDc Max Series-Connected Modules Between MCIs: PVHCS Maximum Circuit Voltage(Array Internal Voltage After Actuation) 165 VDc(cold weather open circuit) *Exception:Tesla S-Series(Tx)xS)modules installed in locations where the max VOC for 3 3* modules at low design temperature exceeds 165V shall be limited to 2 modules between MCIs. Max Series-Connected Panels between MCIs 10 OTHER INSTALLATION INSTRUCTIONS OTHER INSTALLATION INSTRUCTIONS 1.An MCI must be connected to one end of each series string or mounting plane sub-array string. 1.An MCI must be connected to one end of each series string or mounting plane sub-array string. 2.Verification that MCIs are installed with 3 or fewer modules between MCIs shall be documented for inspection, by voltage 2.Verification that MCIs are installed with 10 or fewer modules between MCIs shall be documented for inspection, by voltage measurement logs and/or as-built string layout diagrams. measurement logs and/or as-built string layout diagrams. 3. For PV Inverter:The PVHCS initiator(AC breaker or switch)shall be sized and installed in accordance with NEC requirements. 3. For PV Inverter:The PVHCS initiator(AC breaker or switch)shall be sized and installed in accordance with NEC requirements. The specific part shall be identified on the as-built system drawings. The specific part shall be identified on the as-built system drawings. 4. For Powerwall+:The PVHCS emergency stop initiator shall have the following minimum ratings: Outdoor(Type 3R or higher), 12V, 4. For Powerwall+:The PVHCS emergency stop initiator shall have the following minimum ratings: Outdoor(Type 3R or higher), 12V, 1A, and shall be installed in accordance with NEC requirements.The specific part shall be identified on the as-built system drawings. 1A,and shall be installed in accordance with NEC requirements.The specific part shall be identified on the as-built system drawings. Refer to the Powerwall+installation manual for further details. Refer to the Powerwall+installation manual for further details. (1111) (111) CERTIFIED Certification Mark of UL on the installation instructions is the only method provided by UL to identify products manufactured under its CERTIFIED Certification Mark of UL on the installation instructions is the only method provided by UL to identify products manufactured under its Certification and Follow-Up Service.The Certification Mark for these products includes the UL symbol,the words"CERTIFIED"and Certification and Follow-Up Service.The Certification Mark for these products includes the UL symbol,the words"CERTIFIED"and E515336 E515336 "SAFETY,"the geographic identifier(s),and a file number. "SAFETY,"the geographic identifier(s),and a file number. TEZS-DS-0020-21 TESR-DS-0385-21 t • Energy Purchase Terms Thanks for your purchase! Now that we have completed your order for your Solar System, including any Tesla Powerwall(s) you also ordered (all of which we call your"System" below), the next step is to prepare for and schedule installation of your System. In the meantime, below are some basic terms we need you to agree to in order to make sure we are on the same page (and along with this document are some required disclosures for you to review as well). We look forward to working with you and are excited that you are joining our effort to transition the world to sustainable energy! 1. Your Purchase Price. You have agreed to purchase your System at the price described in your Price Sheet. Your Price Sheet,which is considered part of these purchase terms, includes taxes. You have 7 days after you receive the Price Sheet and these purchase terms to reject them. If you don't reject them, or if you move forward with scheduling your installation, that means you are agreeing to the Price Sheet and these purchase terms. 2. Updates to Price Sheet. Even though we have completed the initial design of your System, we might need to make changes to that design, which also means we might need to update the pricing or System size based on a variety of factors, such as installation complexity or product availability. If that happens, we will update the Price Sheet. You have 7 days after you receive the updated Price Sheet to reject it. If you don't reject it, or if you move forward with scheduling your installation, that means you are agreeing to the updated Price Sheet and authorize us to develop and submit permit packets and otherwise prepare for your upcoming installation. The updated Price Sheet replaces any prior Price Sheet and is considered part of these purchase terms that you are agreeing to (unless you rejected the update). Tesla can also decide to increase the size of your Solar Roof at no additional cost to you. 3. Cancellation. At any point prior to the time when you schedule your installation, you can cancel your order for any reason. And so can we. We both just need to let the other know in writing (so there is no misunderstanding). We will return your order fee for any cancellations up until when you have agreed to final System design and pricing in the Price Sheet, after which your order fee is non-refundable. 4. Home Owner's Association. If your home is governed by a home owner's association or similar community organization, you are responsible for getting any required approvals and authorizations for your System. 5. Installation. We will contact you to schedule installation of your System. During installation, we might choose to make minor repairs commonly needed to install the System at no additional cost to you (like simple electric upgrades and roof preparation).We promise to repair or pay for damage we directly cause to your home or your property during installation of your System. If we fail to do that, please let us know, and we will make the repair (or have someone repair it) at our cost (and that will be your only remedy). But you need to let us know in writing and within a certain amount of time following the damage: within 10 years for Solar System installations, 4 years for Powerwall installations and 1 year for anything else. 6. Equipment Limited Warranties.Your solar panels and inverter come with a warranty from their manufacturers. The solar panel warranty will be at least 25 years and will guarantee at least 80% of nameplate capacity for at least 25 years. Your inverter warranty will cover defects for at least 10 years. You agree we can make warranty claims for you for your solar panels or inverter. If your order includes Powerwall(s), your Powerwall(s)are covered by the Tesla Powerwall Limited Warranty. Theses warranties are considered part of these purchase terms. 7. Remote Monitoring and Firmware Upgrades. You agree that Tesla can access your System remotely to monitor its performance, perform diagnostics and upgrade firmware. 8. Grid Services. We might contact you about ways in which your System can support the reliability of the electrical grid and you agree we can contact you for that reason. 9. Tesla Intellectual Property.Tesla owns all patents, trademarks, copyrights, trade secrets and any other intellectual property rights associated with your System. Tesla gives you a limited, non-exclusive, license to use any software embedded in your System solely in connection with the use and operation of your System. Solar Purchase Agreement V10.5. 12/2/2021 Tesla, Inc. 8222948 10. Limitation of Liability. If there is a dispute, the maximum amount that either of us will have to pay the other is the price in the Price Sheet(as updated, if applicable) for anything arising out of these purchase terms. Also, neither of us will have to pay the other for any indirect damages (what lawyers call "special or consequential damages"). 11. Governing Law. These purchase terms are governed by the laws of the State where your System is installed 12. Notices.You can find applicable lien notices, certain warnings required by law, and details of our insurance attached to these purchase terms. 13. Agreement to Arbitrate. Please read this part carefully because it means you are agreeing that any unresolved dispute between you and Tesla will not be decided by a judge or jury in a public courtroom, but instead by a single arbitrator in a private arbitration. If you have a dispute arising out of or relating to any aspect of the relationship between you and Tesla, Inc. or its affiliates (which we call"Tesla"), please send us an email to resolutions@tesla.com, describing your dispute and how you would like it resolved. If it is not resolved within 60 days from the date of your email, you agree that your dispute can only be resolved by a single arbitrator in an arbitration administered by the American Arbitration Association (AAA) under its Consumer Arbitration Rules. This includes claims arising before you ordered your System (such as claims related to statements Tesla made about our products). We will pay all AAA fees for any arbitration, which will be held in the city or county of your legal residence. To learn more about the Rules and how to begin an arbitration, you can call any AAA office or go to www.adr.org. The arbitrator can only resolve disputes between you and Tesla, and cannot consolidate claims from others without consent from you, Tesla, and the others. You can only bring claims in arbitration against Tesla in your individual capacity and not as a plaintiff or class member in any class or representative action (and the same is true for Tesla). If a court or arbitrator decides that any part of this agreement to arbitrate cannot be enforced as to a specific claim for relief or remedy (such as what lawyers call "injunctive" or "declaratory" relief), then that claim or remedy (and only that claim or remedy)will be carved out of the arbitration and can be filed in court; all other claims must be arbitrated. If you prefer, you can take your individual dispute to a small claims court instead. If you don't want to agree to arbitration, you can "opt out" of arbitration by sending us a letter within 30 days after placing your initial order for your System. Please send the letter to Tesla, Inc.; P.O. Box 15430; Fremont, CA 94539-7970 and include your name, your order number, the name of the product you ordered, and a statement explaining your desire to opt out of arbitration. If you do not opt out, your agreement to arbitrate overrides any different arbitration agreement between us, including any arbitration agreement in a lease or finance contract. Solar Purchase Agreement V10.5. 12/2/2021 Tesla, Inc. 8222948 Solar Purchase Price Sheet (Home Improvement) Your information and installation location vikram sood 329 Rocky Hill Rd Northampton, MA 01062-9793 4134274757 Tesla Notice Information Tesla, Inc. of 3500 Deer Creek Road, Palo Alto, CA, 94304 888-765-2489 MA HIC 187310 Installer Tesla Energy Operations, Inc. of 901 Page Avenue, Fremont, CA 94538 MA HIC 168572/22812-A System and Purchase Price Description of the Project and Description of the Significant Materials to be Used and Equipment to be Installed Solar System $30,384.00 14.4000 kW DC Solar Panels $7,292.16 Installation, Permitting, and Other Fees $17,318.88 Inverter(s) & Balance of System $4,253.76 Mounting Hardware $1,519.20 Powerwall $10,500.00 1 x Powerwall $8,500.00 (Includes integrated or separate System communication device) Powerwall Installation $3,500.00 Powerwall + Solar Discount ($1,500.00) Taxes $0.00 Contract Price $40,884.00 Credit for Order Payment ($250.00) Amount Due $40,634.00 Schedule of Payments Paid at Order $250.00 Due Within Five (5) Days of Inspection $40,634.00 The schedule of progress payments must specifically describe each phase of work, including the type and amount of work or services scheduled to be supplied in each phase, along with the amount of each proposed progress payment. IT IS AGAINST THE LAW FOR A CONTRACTOR TO COLLECT PAYMENT FOR WORK NOT YET COMPLETED, OR FOR MATERIALS NOT YET DELIVERED. HOWEVER, A CONTRACTOR MAY REQUIRE A DOWNPAYMENT. Solar Purchase Agreement V10.5. 12/2/2021 Tesla, Inc. 8222948 Approximate Installation Start Date 7-90 days from contract signing Approximate Completion Date 7-90 days from the day installation begins Signed by Your signature vikram sood Tesla, Inc. Name: vikram sood Date: 5/1/2022 3:06:40 PM +00:00 Name:Yaron Klein Title:VP, Financial Services &Treasurer You are entitled to a completely filled in copy of this Agreement, signed by both you and Tesla, before any work may be started. Solar Purchase Agreement V10.5. 12/2/2021 Tesla, Inc. 8222948 Exhibit 1 Cancellation Rights (TESLA, INC. COPY) NOTICE OF CANCELLATION STATUTORILY-REQUIRED LANGUAGE Notice of Cancellation Date of Transaction: 5/1/2022 3:06:40 PM +00:00 You may CANCEL this transaction, without any penalty or obligation, within THREE BUSINESS DAYS OR FIVE BUSINESS DAYS (CA CUSTOMERS ONLY)from the above date. If you cancel, any property traded in, any payments made by you under the contract or sale and any negotiable instrument executed by you will be returned within TEN DAYS following receipt by the seller(Tesla, Inc.) of your cancellation notice, and any security interest arising out of the transaction will be canceled. If you cancel, you must make available to the seller(Tesla, Inc.) at your residence, in substantially as good condition as when received, any goods delivered to you under this contract or sale, or you may, if you wish, comply with the instructions of the seller(Tesla, Inc.) regarding the return shipment of the goods at the seller's (Tesla, Inc.'s) expense and risk. If you do make the goods available to the seller(Tesla, Inc.) and the seller(Tesla, Inc.) does not pick them up within 20 days of the date of your notice of cancellation, you may retain or dispose of the goods without any further obligation. If you fail to make the goods available to the seller (Tesla, Inc.), or if you agree to return the goods to the seller (Tesla, Inc.) and fail to do so, then you remain liable for performance of all obligations under the contract. To cancel this transaction, mail or deliver a signed and dated copy of this cancellation notice, or any other written notice to Tesla, Inc., Document Receiving, 6569 Las Vegas Blvd. S., Unit 200, Las Vegas, NV 89119 NO LATER THAN MIDNIGHT of the date that is THREE BUSINESS DAYS OR FIVE BUSINESS DAYS (CA CUSTOMERS ONLY)from the date you signed the Agreement. I, , hereby cancel this transaction on [Date]. Customer's Signature: Customer's Signature: Solar Purchase Agreement V10.5. 12/2/2021 Tesla, Inc. 8222948 (CUSTOMER COPY) NOTICE OF CANCELLATION STATUTORILY-REQUIRED LANGUAGE Notice of Cancellation Date of Transaction: 5/1/2022 3:06:40 PM +00:00 You may CANCEL this transaction, without any penalty or obligation, within THREE BUSINESS DAYS OR FIVE BUSINESS DAYS (CA CUSTOMERS ONLY)from the above date. If you cancel, any property traded in, any payments made by you under the contract or sale and any negotiable instrument executed by you will be returned within TEN DAYS following receipt by the seller(Tesla, Inc.)of your cancellation notice, and any security interest arising out of the transaction will be canceled. If you cancel, you must make available to the seller(Tesla, Inc.) at your residence, in substantially as good condition as when received, any goods delivered to you under this contract or sale, or you may, if you wish, comply with the instructions of the seller (Tesla, Inc.) regarding the return shipment of the goods at the seller's (Tesla, Inc.'s) expense and risk. If you do make the goods available to the seller(Tesla, Inc.) and the seller(Tesla, Inc.) does not pick them up within 20 days of the date of your notice of cancellation,you may retain or dispose of the goods without any further obligation. If you fail to make the goods available to the seller(Tesla, Inc.), or if you agree to return the goods to the seller(Tesla, Inc.) and fail to do so, then you remain liable for performance of all obligations under the contract. To cancel this transaction, mail or deliver a signed and dated copy of this cancellation notice, or any other written notice to Tesla, Inc., Document Receiving, 6569 Las Vegas Blvd. S., Unit 200, Las Vegas, NV 89119 NO LATER THAN MIDNIGHT of the date that is THREE BUSINESS DAYS OR FIVE BUSINESS DAYS (CA CUSTOMERS ONLY)from the date you signed the Agreement. I, , hereby cancel this transaction on [Date]. Customer's Signature: Customer's Signature: Solar Purchase Agreement V10.5. 12/2/2021 Tesla, Inc. 8222948 • Exhibit 2 NOTICES Bonds. The owner or tenant has the right to require the contractor to have a performance and payment bond. Extra Work and Change Orders. Extra Work and Change Orders become part of the contract once the order is prepared in writing and signed by the parties prior to commencement of any work covered by the new change order. You may not require a contractor to perform extra or change-order work without providing written authorization prior to the commencement of work covered by the new change order. Extra work or a change order is not enforceable against you unless the change order also identifies all of the following in writing prior to the commencement of work covered by the new change order:(i) the scope of the extra work or change, (ii) the cost to be added or subtracted from the contract; and (iii) the effect the order will have on the schedule of progress payments or the completion date. Notwithstanding this provision, the Contractor shall have the right to substitute System equipment without Customer's agreement, so long as that substitution adds no extra cost to the project and does not materially affect the System's performance. The Contractor's failure to comply with the requirements of this paragraph does not preclude the recovery of compensation for work performed based on legal or equitable remedies designed to prevent unjust enrichment. Insurance Tesla carries the following insurance applicable to the work being performed under this Agreement: • Commercial General Liability Insurance (CGL). Tesla carries commercial general liability insurance with coverage amounts that meet or exceed those required by law. • Workers' Compensation Insurance. Tesla carries workers' compensation insurance for all employees in compliance with law. Solar Purchase Agreement V10.5. 12/2/2021 Tesla, Inc. 8222948 Additional Notices Massachusetts MASSACHUSETTS CONTRACTOR LICENSING INFORMATION: All contractors and subcontractors must be registered by the Director of Massachusetts' Office of Consumer Affairs and Business Regulation and that any inquiries about a contractor or subcontractor relating to a registration should be directed to the Director. MASSACHUSETTS NOTICE TO BUYERS: You have warranties and rights under Massachusetts General Law Chapter 142A. Tesla hereby makes such warranties and nothing in this Agreement waives your rights under Massachusetts General Law Chapter 142A. Solar Purchase Agreement V10.5. 12/2/2021 Tesla, Inc. 8222948 [THIS PAGE INTENTIONALLY LEFT BLANK] Certificate of Completion EnvelopeID: 4be2b1 bf-6753-4774-bf9f-80c750bdc4ab Subject: Document Generated: Signer Events vikram sood Signed: 5/1/2022 3:06:40 PM +00:00 Using IP Address: 2601:193:8380:1a00:a5d7:23c1:3e1e:ef6b