Loading...
32C-318 (8) 47 HENRY ST COMMONWEALTH OF MASSACHUSETTS BP-2021-1915 Map:Block:Lot:32C-318- 001 CITY OF NORTHAMPTON Permit: Solid Fuel Appliance PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Penn it# BP-2021-1915 PERMISSIONIS HEREBY GRANTED TO: Project# PELLET STOVE Contractor: License: Est. Cost: THE FIRE PLACE 99401 Const.Class: Exp.Date:01/06/2022 Use Group: Owner: BENSONOFF DANIEL &KOKORO Lot Size (sq.ft.) Zoning: URC Applicant: THE FIRE PLACE Applicant Address Phone: Insurance: PO BOX 606 (413)397-3463 01400503301116 WHATLEY, MA 01093 ISSUED ON:09/22/2021 TO PERFORM THE FOLLOWING WORK: PELLET STOVE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: I., • + yQ , � Fees Paid: $40.00 212 Main Street, Phone(413)587-1240,Fax:(413)587-1272 Office of the Building Commissioner c N City of Northampton ,oft v_r,,,„ `s-a. 6r Massachusetts w' ..- ;cam & ,t c t'-.I 0`' .'till DEPARTMENT OF BUILDING INSPECTIONS ,- ' 5 o §n' `'." 212 Main Street • Municipal Building rv,� .tia NI is .. Northampton, MA 01060 ss;`.'„�S4' , j c.z ;1-M LICATION FOR SOLID FUEL APPLIANCE INSTALLATION Property Information Owners Name: ")a n lc f 3e n ,,gno Address: y7 /IrsT Sirs > A or1A,,nip/on (No.) (Street Address) Phone: y/_- 6 95: 44 5/S Cell: Email: gn Q � - � Date: �^I2'Z\ Owners Signature: Contractor's Information (If Applicable) Name: 7)o u ./tS L 1).4?c fc.l7lt ec_ Phone: d/3 %1 554 Construction Supervisor's License #: /9VO / Expiration: /-L .? Home Impr. Contractor License #: /1GS/77 Expiration: //-/P�.2 Stove Information Type of Fuel (check all that apply): Wood Pellet Coal Location: OcnLdoor - yvrt Freestanding Y Insert Manufacturer: kid rol en Model: 75/ pc/A - FOR BUILDING DEPARTMENT USE ONLY Permit# Date Applied: Total all Fees: $ Building Official: h eimi Kp55 Date Issued: 9- Z2-202 i % Signature of Building Official: '�— r, The Conrnronwealth of Massachusetts F:�� j,� Department of Industrial Accidents "1)• :��1r--;; Office of Investigations i Lafayette City Center — t ;� • 2 Avenue de Lafayette, Boston,NIA 02111-1750 ._ www.njass.gov/dia Workers' Compensation Insurance Affidavit: General Businesses Applicant Information Please Print Legibly Business/Organization Name:THE FIRE PLACE Address: 100 STATE RD City/State/Zip:WHATELY, MA 01093 Phone#:413-397-3463 Are you an employer? Check the appropriate box: Business Type(required): 1.0 I am a employer with 10 employees (full and/ 5. ❑ Retail or part-time).'` 6. ❑ Restaurant/Bar/Eating Establishment 2.❑ i am a sole proprietor or partnership and have no 7. ❑ Office and/or Sales(incl.real estate,auto.etc.) employees working for me in any capacity. [No workers' comp. insurance required] 8. ❑Noo-profit 3.❑ We are a corporation and its officers have exercised 9. ❑ Entertainment their right of exemption per c. 152, §1(4),and we have 10.0 Manufacturing no employees. [No workers' comp. insurance required]" 11.❑ Health Care 4.❑ We are a non-profit organization,staffed by volunteers, with no employees. [No workers' comp. insurance req.] 12.E Other "Any applicant that checks box_1 must also till out the section below showing their workers'compensation policy information. • ll*If the corporate officers have exempted themselves.but the corporation has other employees-a workers'compensation policy is required and such an organization should check box#I. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy information. insurance Company Name:MA RETAIL MERCHANTS WC GROUP INC Insurer's Address: P.O. BOX 859222-9222 Cite State Zit): BRAINTREE, MA 02185 Polio = or Self-ins. Lic. =01400503301116 Expiration Date: 1-1-22 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under§25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to S1.500.00 and'or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORI)ER and a fine of up to S250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and per alties ofperjury that the information provided above is true and correct. C.Signature: (/ '-C./& ' . a Date: 9• 1 02/ Phone=: '/" J ri .3V 3 I Official use only. Do not write irr this area,to be completed by city or town official City or Town: Permit/License# Issuing Authority(check one): 1.❑Board of Health 2.0 Building Department 3.❑City/Town Clerk 4.0Licensing Board 5.0 Selectmen's Office 6.['Other Contact Person: Phone#: v v.mass.aov/dia 4 Termination Location and Vent Information A. Vent Termination Minimum Clearances Note: Follow venting manufacturer's recommendations for sealing pipe joints. #1 Preferred method (Figure 4.1) This method provides excellent venting for normal operation and allows the stove to be installed closest to the wall. Two inches from the wall is safe; however, four inches allows better access to remove the rear panel.The vertical portion of the vent should be three to five feet high.This vertical section will help provide natural draft in the event of a power failure. Do not place joints within wall pass-through. L 3 Ft. to Combustibles 4 \ e A- _ . ' r 'I 3 Ft. to Combustibles Figure 4.1 _\ #2 Preferred method (Figure 4.2) \ This method also provides excellent venting for normal operation but requires the stove to be installed farther from the wall. The vertical portion of the vent should be three to five feet high and at least 1" from a combustible wall. This — vertical section will provide natural draft in the event of a power failure. _ If the stove is installed below grade be sure the vent C. [= i I termination is at least 12"above grade. The outlet must also be 1 foot from the house/building. 3 to Ft. Do not place joints within wall pass-through. Combustibles A CAUTION - \ Keep combustible materials (such as grass, leaves, etc.) at least 3 feet away from the flue outlet on the - outside of the building. 4 yl ram _ 3 Ft. to Combustibles Figure 4.2 11 Harman® • P-Series Installation Manual_R4 • 2018- - 04/21 8390-0441 • B. Chimney Diagram IIID AE L Detail b IN re / closed r — —B .- Porch or Deck olenanb' vexedIN Openable or Fined L o F B used C NNNv ,Openable 11111111111 Sidewalk B l j MIIMIIIIIIIk A K i --9 ri=Vent Terminal 0 =Air Supply Inlet v A =Area where termination is not permitted Figure 4.10 Requirements for Terminating the Venting I. The clearance to service regulator vent outlet must be a • Venting terminals must not be recessed into a wall minimum of 6 feet. or siding. J. The clearance to a non-mechanical air supply inlet to the • Only PL vent pipe wall pass-through and fire stops building or the combustion air inlet to any other appliance should be used when venting through combustible must be a minimum of 48". materials. K. The clearance to a mechanical air supply inlet must be a • Always take into consideration the effect the minimum of 10 feet. (with outside air installed, 6 feet) prevailing wind direction or other wind currents will L. The clearance above a paved sidewalk or a paved cause with flyash and /or smoke when placing the driveway located on public property must be a minimum termination. of 7 feet. In addition, the following must be observed: M. The clearance under a veranda, porch, deck or balcony A. The clearance above grade must be a minimum of 12". must be a minimum of 12 inches. (B. also) B. The clearance to a window or door that may be opened Note: The clearance to vegetation and other exterior must be a minimum of 48"to the side and 48" below the combustibles such as mulch is 36" as measured from window/door, and 12" above the window/door. (with the center of the outlet or cap.This 36"radius continues outside air installed, 12" to side and below) to grade. C. A 12" clearance to a permanently closed window is Certain Canadian and or Local codes or regulations may recommended to prevent condensation on the window. require different clearances. D. The vertical clearance to a ventilated soffit located above A vent shall not terminate directly above a side-walk or the terminal within a horizontal distance of 2 feet(60 cm) paved driveway which is located between two single family from the center-line of the terminal must be a minimum dwellings and serves both dwellings. of 18". Only permitted if veranda, porch, deck, or balcony is fully E. The clearance to an unventilated soffit must be a open on a minimum of 2 sides beneath the floor. minimum of 12". See NFPA 211 for more installation clearance reductions F. The clearance to an outside corner is 11"from center of when using outside air. Where passage through a wall, pipe or partition of combustible construction is desired, the installation shall conform to CAN/CSA-B365. (if in G. The clearance to an inside corner is 12". Canada) H. A vent must not be installed within 3 feet(90 cm)above a gas meter/regulator assembly when measured from the horizontal center-line of the regulator. 15 Harman® • P-Series Installation Manual_R4 • 2018- • 04/21 8390-0441 • B. Clearances to Combustibles Place the stove away from combustible walls at least as far When selecting a location for the appliance it is important to as shown in Figure 3.2. Please note the difference in side consider the required clearances to walls, Figure 3.2. wall clearance with and without side shields. Note that the clearances shown are minimum for safety but do A WARNING not leave much room for access when cleaning or servicing. Please take this into account when placing the stove. RISK OF FIRE OR BURNS! Provide adequate Due to high temperatures, the stove should be placed out of clearance around air openings and for service traffic and away from furniture and draperies. access. Due to high temperatures, the appliance should Children and adults should be alerted to the hazards of high be located out of traffic and away from furniture and surface temperatures and should stay away to avoid burns draperies. to skin and/or clothing. Young children should be carefully supervised when they are ACAUTION in the same room as the stove. Clothing and other flammable materials should not be placed THIS APPLIANCE MUST BE VENTED TO THE OUTSIDE. on or near this unit. NOTICE:Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY.Actual installation may vary due to individual design preference. P61-C & P68-C Freestanding Pellet Stove P43-C Freestanding Pellet Stove 14"(355mm) with 2"(51mm) *10"(254mm) with 2"(51mm) side shields / \ ? side shields 0 20"(508mm) *16"(406mm) without side shields o 14"(355mm) without side shields Limmdim_io *10"(254mm) 20"(508mm) *16"(406mm) 36"(914mm) 36"(914mm) 9"(228mm)- 9"(228mm) 13"(330mm) o i o 0 •\1, co -- fp N co co N, 9"(228mm)With Side Shields 3 13"(330mm) Without Side Shields 9"(228mm) With or Without Side Shields Figure 3.2 9 Harman® • P-Series Installation Manual_R4 • 2018- • 04/21 8390-0441 C. Floor Protection Corner Installation: Parallel Installation: Minimum size floor protection for a corner installation hearth pad is: Place the stove on a noncombustible type floor or floor P43-C - Minimum size floor protection is 25-7/16" Wide by protector that extends a minimum of 6 inches (152mm) to 26-3/4" Deep (646mm X 680mm). the front of the load door opening, 6 inches (152mm)to the sides of the door opening, and 6 inches to the rear. P61-C - Minimum size floor protection is 25-1/8" Wide by The P-Series does not require R value floor protection. 27-3/4" Deep (638mm X 705mm). The minimum floor protector material is 20 gauge sheet metal. P68-C - Minimum size floor protection is 25-3/16" Wide by Other floor protector materials that can be used include Type 27-3/4" Deep (640mm X 705mm). I hearth pads, ceramic tile, stone, brick, etc. Figure 3.3 Note: Floor protector WILL NOT touch the wall using *Floor protection dimensions for the front and sides are minimum clearances. measured from the appliance door opening in The United If corner floor protection is desired to touch the wall, the States. In Canada,the side dimension is measured from the floor protection will need to be at least 40" x 40" (1016mm widest part of the appliance. x 1016mm). Note: This will allow the floor protection to P43-C - Minimum size rectangular floor protection is 25- touch the wall as shown. Figure 3.4. 7/16"Wide by 26-3/4" Deep (646mm X 680mm). Alternate floor protector dimension may be used as long as P61-C-Minimum size rectangular floor protection is 25-1/8" they satisfy the measurement requirements shown below. Wide by 27-3/4" Deep (638mm X 705mm). P68-C - Minimum size rectangular floor protection is 25- 3/16"Wide by 27-3/4" Deep (640mm X 705mm). Venting: US-Follow PL vent manufacturers recommendations when configuring vent pipe installation. Canada - Must extend 2" (51mm) beyond each side of any horizontal flue pipe. 4Ij; I 0 0 L 0 111111 Figure 3.4 D. Mobile Home Installation When installing this unit in a mobile home, several requirements must be followed: J Floor Protector 1. The unit must be bolted to the floor. This can be done K using an appropriate fastener for the application. Figure 3.3 2. The unit must also be connected to outside air. See "Termination Location and Vent Information" Section D. Floor Protection 3. Floor protection and clearances must be followed as Requirements 01 Canada shown. J Sides 6" 152mm 4. The appliance must be properly grounded to the frame of K Front 6" 152mm the mobile home using a minimum of 8 AWG copper solid L Rear 6" 152mm or stranded, insulated or bare wire or equivalent. 10 Harman® • P-Series Installation Manual R4 • 2018- • 04/21 8390-0441