RVC Nton - post base repair - SK 6-22-21 (2)14" 12" 1/4" x 1 3/4" TAPCON 1/4" x 2 1/4" TAPCON 6 x 2 x 516 PAINTED ANGLE ROD EMBEDDED IN POST 6 x 6 POST EPDM PAD4"CHESTER GRANIT STONE PLINTH 2" 5/16" x 3 1/2" GRK RSS SCREW Drawing No. 49 Mount Warner Road Date: Hadley, MA 01035 P-413-586-3045 F-586-3046 Scale: Job Name: P.O. Box 719 & Millwork Inc. Architectural Timber Title: Print Date:6/22/21 6/8/21 RIVE-04-T-04 River Valley Co-Op Northampton 3" = 1'-0" Replacement Post Base - Option 1a SK-1A 612" 35 8"14"7"612"14"14"3"3"1"234"212"14"HOLE SIZE AND LOCATION T.B.D. Drawing No. 49 Mount Warner Road Date: Hadley, MA 01035 P-413-586-3045 F-586-3046 Scale: Job Name: P.O. Box 719 & Millwork Inc. Architectural Timber Title: Print Date:6/22/21 6/22/21 RIVE-04-T-04 River Valley Co-Op Northampton 3" = 1'-0" Proposed Granit Plinth SK-2