Loading...
Landers-plansetRELEASEREVDATE NAMEGOVERNING CODESPARCEL MAP PROJECT LOCATION SHEET INDEX ENGINEERED BY: CONTRACTOR: CONTRACTOR LIC #: PHONE: CONTACT NAME: PHONE: EMAIL: DESIGN BY: PHONE: HOME OWNER PROJECT LOCATION: PROJECT DRAFTER: LICENSE #: PHONE: ELECTRICAL UTILITY: AUTHORITY HAVINGJURISDICTION: BUILDING: CONTACT NAME:PHONE: LICENSE TYPE: PHONE: EMAIL: EMAIL: PHONE:COVER SHEETSHEET SHEET TITLE EMAIL:APNAdvancedSolarSolutions39650MallardBassLake,CA93604 PHONE: 559-321-7000EMAIL: info@advpermits.com ADDRESS ADDRESS kW PHOTOVOLTAIC PLANS PROJECT APN: GENERAL PROJECT & JURISDICTIONAL NOTES 1. UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT EXPRESSEDWRITTEN PERMISSION FROM THE CONTRACTOR AND ADVANCED SOLAR SOLUTIONS IS A VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTION. APPLICABLE BUILDING CODES: INTERNATIONAL BUILDING CODE INTERNATIONAL RESIDENTIAL CODE INTERNATIONAL FIRE CODE NATIONAL ELECTRIC CODE DESIGN CRITERIA BUILDING OCCUPANCY: RISK CATEGORY: EXPOSURE CATEGORY: SNOW LOAD: SNOW EXPOSURE: CONSTRUCTION TYPE: SCOPE OF WORK NUMBER PROPOSED SOLAR EQUIPMENT SITE / PROJECT DETAILS QTY. EQUIPMENT DESCRIPTION/MFG/MODEL MODULES INVERTER(S) RACKING STANCHIONS RSD DEVICE BATTERIES SYSTEM SIZE DC SYSTEM SIZE AC QTY. STRING/CKT. ELECT. SERVICE PROJECT TEAM LIST COPYRIGHT NOTICE 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH ALL OSHA REGULATIONS. 2. PENDING LOCAL JURISDICTIONAL REQUIREMENTS AND WHEN APPLICABLEALL ELECTRICAL ENCLOSURE DEAD FRONTS, COVERS, DOORS, ETC. SHALE BE OPEN AND ACCESSIBLE FOR INSPECTIONS. WHEN TRENCH AND ROOF INSPECTIONSARE REQUIRED WORK SHALL BE OPEN AND ACCESSIBLE FOR INSPECTOR. INSPECTION REQUIREMENTS 1. WHEN APPLICABLE A SMOKE DETECTOR, APPROVED AND LISTED BY THE STATE FIRE MARSHAL OR ANSI/UL 217 CERTIFIED TO NATIONAL FIRE ALARM AND SIGNALING CODE, NFPA 72 SHALL BE VERIFIED FUNCTIONAL OR INSTALLED IN ALL APPLICABLE CODE REQUIRED LOCATIONS. 2. ALL APPLICABLE EQUIPMENT TO BE UL LISTED OR LISTED BY OTHERJURISDICTIONAL AND UTILITY APPROVED ASSOCIATION OR NATIONALLY RECOGNIZED ORGANIZATION. 3. FULL SCOPE OF WORK SHALL COMPLY WITH ALL APPLICABLE CODES LISTED IN GOVERNING CODES SECTION, ALL MANUFACTURES' LISTINGS, INSTALLATION INSTRUCTIONS AND SPECIFICATIONS AND JURISDICTIONAL REQIREMENTS. JURISDICTIONAL & LISTING REQUIREMENTS 4. REVISED PLANS WILL BE REQUIRED TO BE RESUBMITTED TO THE LOCALJURISDICTION IF THE INSTALLED ARRAY AND ASSOCIATED EQUIPMENT DOES NOT MATCH THE APPROVED BUILDING PLANS. ADDITIONAL FEES MAY ALSOAPPLY. 5. THE PLACEMENT OF A UTILITY PV PRODUCTION METER SHALL BE PROVIDEDAND PLACED BY THE CONTRACTOR AS PER APPLICABLE UTILITY OR AHJREQUIREMENTS. MSP RATINGS COMBINER(S) AZIMUTH TILT ROOF COVERING NORTHDRIVEWAYSMITH ST ⅊ ⅊ ⅊ ⅊SERVICE CENTER RDSER V IC E C EN TE R R D N/A III-B 15.050 KW PV-001 COVER SHEET Landers, Jo Jake Stocker 2015 National Grid 2015 591759978 2015 21134A(413) 584-8844 2020 Lilian Wanjiku(413) 584-8844 City of Northampton jstocker@valleysolar.solar M Risk Category II Exposure C 40 (413) 584-8844jstocker@valleysolar.solar Landers, Jo6 Service Center Rd #2, Northampton, MA 01060 ROOF MOUNTED PV (SOLAR) PROJECT GRID-TIED W/ BATTERY STORAGE 340 Riverside Dr Valley Solar Florence, MA 01062 Q-Cells Q.PEAK DUO L-G8.2 430GENERAC PWRcell XVT076A03 EcolibriumSolar EcoFoot 2+ Ballast Blocks SnapRS Device Generac PWRcell 18 kWh 351 N/A 92 35 1 N/A (E) GPS COORDINATES:(42.3139093,-72.6341508) 7.600 KW 6 120/240V - 1 2° 215° MAX ARRAY HGT. 117 N/AMEMBRANE N-001 GENERAL NOTES PV-100R PV ARRAY LAYOUT S-100 RACKING LAYOUT S-200 SECTION ELEVATION S-201 ATTACHMENT DETAILS E-001 EQUIP. CALCULATIONMETER NUMBER:E-002 WIRE AND COND. CALCS E-003 THREE LINE DIAGRAM E-100 ELECTRICAL LAYOUT P-001 STANDARD PLACARDS P-002 DYNAMIC PLACARDS R-1xx EQUIP.CUT SHEETS N/A 200A BUS/200A MAIN BREAKER BACK-FED BREAKER PV-001ASCE 7-10 WIND SPEED:Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884415.050Landers, Jo6 Service Center Rd #2Northampton, MA 0106006/09/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNGENERAL NOTES ADDRESS kW PHOTOVOLTAIC PLANS GENERALNOTES:* PROPERACCESSANDWORKINGCLEARANCEAROUND EXISTINGANDPROPOSEDELECTRICALEQUIPMENTWILLBE PROVIDEDASPERSECTIONNEC110.26. PVSYSTEMCOMPONENTS;INCLUDINGBUTNOTLIMITED TO,MODULES,INVERTERSANDSOURCECIRCUIT COMBINERSAREIDENTIFIEDANDLISTEDFORUSEINPV SYSTEMSINCOMPLIANCEWITHNEC690.4AND690.6 ANDALLUL,IEC,IEEECLASSIFICATIONSAS REQUIREMENTS. RAPIDSHUTDOWNNOTES:* PVSYSTEMCIRCUITSINSTALLEDONORINBUILDIDNG SHALLINCLUDEARAPIDSHUTDOWNFUNCTIONTHAT CONTROLSSPECIFICPVCONDUCTORSINACCORDANCE WITH2020NEC690.12(A)-(D) EQUIPMENTLOCATIONS&ELECTRICAL NOTES:* JUNCTIONANDPULLBOXESAREPERMITTEDTOBE INSTALLEDUNDERPVMODULESINCOMPLIANCEWITH NEC690.34. ADDITIONALACDISCONNECT(S)SHALLBEPROVIDED WHERETHEINVERTERISNOTWITHINSIGHTOFTHEAC SERVICINGDISCONNECT.2020NEC690.15(A) ALLEQUIPMENTSHALLBEINSTALLEDACCESSIBLETO QUALIFIEDPERSONNELINCOMPLIANCEWITHNEC APPLICABLECODES. ALLCOMPONENTSARELISTEDFORTHEIRINTENDED PURPOSEANDRATEDFOROUTDOORUSAGEWHEN APPLICABLE. STRUCTURALANDINSTALLATION NOTES:* RACKINGSYSTEM&PVPANELSMOUNTEDONA ROOFTOPSHALLBELISTEDANDLABELEDINACCORDANCE WITHUL1703ANDSHALLBEINSTALLEDINACCORDANCE WITHTHEMANUFACTURERINSTALLATIONINSTRUCTIONS. ALLPVRACKINGATTACHMENTPOINTSSHALLNOTEXCEED THEPRE-ENGINEEREDMAXSPANSOUTLINEDBYTHE RACKINGMANUFACTURESENGINEEROFRECORD. GROUNDINGNOTES:* INUNGROUNDEDSYSTEMSONLYTHEDCCONDUCTORS AREUNGROUNDEDANDREQUIREANEQUIPMENT GROUNDINGCONDUCTOR.ALLMETALELECTRICAL EQUIPMENTANDSTRUCTURALCOMPONENTSBONDEDTO GROUND,INCOMPLIANCEWITHNEC250.134ANDNEC 250.136(A). PVEQUIPMENTINCLUDINGMODULEFRAMESANDOTHER METALPARTSSHALLBEGROUNDEDINCOMPLIANCE WITHNEC690.43ANDMINIMUMGROUND CONDUCTORSSIZEDINACCORDANCEWITHNECTABLE 250.122. CONDUCTIVEPARTSOFMODULEFRAMES,MODULE RACKING,ANDENCLOSURESSHALLBEGROUNDEDIN COMPLIANCEWITHNEC250.134ANDNEC250.136(A). UL2703APPROVEDMODULEANDRACKGROUNDING SHALLBEUSEDANDINSTALLEDPERMANUFACTURER'S INSTALLATIONMANUAL.IFUL2703APPROVED GROUNDINGISNOTUSED,MODULEGROUNDINGLUGS MUSTBEINSTALLEDATTHESPECIFIEDGROUNDINGLUG HOLESPERTHEMANUFACTURER'SINSTALLATION REQUIREMENTS. THEGROUNDINGCONNECTIONTOAMODULESHALLBE ARRANGEDSUCHTHATTHEREMOVALOFAMODULEDOES NOTINTERRUPTAGROUNDINGCONDUCTORTOANOTHER MODULE. THEGROUNDINGELECTRODESYSTEMCOMPLIESWITH NEC690.47ANDNEC250.50THROUGHNEC250.106. IFEXISTINGSYSTEMISINACCESSIBLEORINADEQUATE,A GROUNDINGELECTRODESYSTEMWILLBEPROVIDEDIN COMPLIANCEWITHNEC250,NEC690.47ANDAHJ. PVSYSTEMSSHALLBEPROVIDEDWITHDCGROUND- FAULTPROTECTION2020NEC690.41(B) INTERCONNECTION/POCNOTES:* ALLLOAD-SIDEINTERCONNECTIONSAREINCOMPLIANCE WITH2020NEC705.12(B) THETOTALRATINGOFALLOCPDINSOLARLOADCENTERS SHALLNOTEXCEEDTHERATEDAMPACITYOFTHEBUSBAR EXCLUDINGTHEOCPDPROTECTINGTHEBUSBARIN COMPLIANCEWITHNEC705.12(B)(2)(3)(c) ALLFEEDERTAP(LOADSIDE)INTERCONNECTIONSAREIN COMPLIANCEWITH2020NEC705.12(B)(2)(1) THEPVSYSTEMBACK-FEEDBREAKERSHALLBEINSTALLED ONTHEOPPOSITEENDOFTHEBUSBARANDITSHALL ALSOBESIZEDAPPROPRIATELYASPER2020NEC 705.12(B)(2)(3)(b) SUPPLYSIDETAPINTERCONNECTIONSAREIN COMPLIANCEWITHNEC705.12(A)WITHSERVICE ENTRANCECONDUCTORSINCOMPLIANCEWITHNEC 230.42 BACKFEEDINGBREAKERFORINVERTEROUTPUTISEXEMPT FROMADDITIONALFASTENING2020NEC705.12(B)(5) MICROINVERTERBRANCHCIRCUITSSHALLBECONNECTED TOASINGLEOCPDINACCORDANCEWITHTHEIR INSTALLATIONINSTRUCTIONSANDNEC690.9 DISCONNECTSANDOCPDNOTES:* ALLDISCONNECTINGSWITCHESWILLBECONFIGUREDSO THATALLENERGIZEDCONDUCTORSWHENDISCONNECTIS OPENSHALLBEONTHETERMINALSMARKED,“LINESIDE” (TYPICALLYTHEUPPERTERMINALS) ALLACDISCONNECTSSHALLBELABELED,LOCKABLE,OF VISIBLEBREAKTYPESWITCHWITHEXTERNALHANDLEAND ACCESSIBLETOQUALIFIEDUTILITYPERSONNEL. ACDISCONNECTSSHALLBEA“KNIFEBLADE”TYPE DISCONNECT.IFEXTERIOR,RATEDTONEMA3RORBETTER PERNEC110.28 ADDITIONALACDISCONNECTSSHALLBEPROVIDED WHERETHEINVERTERISNOTADJACENTTOTHEUTILITY ACDISCONNECT,ORNOTWIHTINSIGHTOFTHEUTILITYAC DISCONNECT.2020NEC690.15(A) BOTHPOSITIVEANDNEGATIVEPVCONDUCTORSREMAIN UNGROUNDED.THEREFORE,BOTHSHALLREMAINOPEN WHEREADISCONNECTISREQUIREDINCOMPLIANCEWITH 2020NEC690.15(D) ALLOCPDRATINGSANDTYPESSPECIFIEDSHALLBEIN COMPLIANCEWITHNEC690.8,690.9,705.12AND240. BOTHPOSITIVEANDNEGATIVEDCPVCONDUCTORSARE UNGROUNDED;BOTHREQUIREOVERCURRENT PROTECTIONINCOMPLIANCEWITHNEC690.9 ARCFAULT(AFCI)DCCIRCUITPROTECTIONISREQUIRED FORALLPVSYSTEMSONORPENETRATINGABUILDING WITHAMAXIMUMSYSTEMVOLTAGEOF80VOLTSOR GREATER.ALLDCPVCIRCUITSINSTALLEDINORON BUILDINGSWILLBEARC-FAULTCIRCUITPROTECTEDIN COMPLIANCEWITHNEC690.11,UL1699BANDSHALLBE LISTEDANDLABELEDINACCORDANCEWITHUL1699(B). WIRING&CONDUITNOTES:* ALLCONDUITANDCONDUCTORSSHALLBEAPPROVED FORTHEIRINTENDEDPURPOSEINCLUDINGWET LOCATIONSANDEXPOSEDTOSUNLIGHT.CONDUITAND CONDUCTORSIZESPECIFICATIONSAREBASEDONTHE MINIMUMCODEREQUIREMENTSANDARENOTLIMITED TOUPSIZING. ALLCONDUCTORSSHALLBESIZEDINCOMPLIANCEWITH NEC690.8,NEC690.7. ALLCONDUCTORSSHALLBEDERATEDASAPPLICABLETO THEIRRESPECTIVEENVIRONMENTINCLUDINGDIRECT SUNLIGHTINACCORDANCEWITH2020NEC 310.15(B)(3)(4)(c) EXPOSEDUNGROUNDEDDCPVSOURCEANDOUTPUT CIRCUITSSHALLUSECONDUCTORSLISTEDANDIDENTIFIED ASPHOTOVOLTAIC(PV)WIREINCOMPLIANCE2020NEC 690.31(C)(1).PVMODULESWIRELEADSSHALLBELISTED FORUSEWITHUNGROUNDEDSYSTEMSINCOMPLIANCE WITH2020NEC690.4(B) PVWIREBLACKWIREMAYBEFIELD-MARKEDWHITEIN COMPLIANCEWITHNEC200.6(A)(6). PVMODULECONDUCTORSLOCATEDUNDERARRAYSWILL BESECUREDINAWORKMANLIKEMANNERIN COMPLIANCEWITHNEC110.12. WATERPROOFING:* ALLNEWROOFTOPPENETRATIONSSHALLBESEALEDAND MADEWEATHERTIGHTWITHAPPROVEDCHEMICAL SEALANTANDFLASHINGSWHEREREQUIREDPERCODE ANDGENERALBUILDINGANDROOFINGWORKMANSHIP STANDARDSBYALICENSEDCONTRACTOR. ALLEXTERIORELECTRICALEQUIPMENT,SHALLBENEMA 3RORBETTERRATED.ALLEXTERIORCONDUITAND CONNECTORSSHALLBERATEDFORWETLOCATIONS. *ALLNOTESAREASAPPLICABLETOTHISPROJECT. DISREGARDANYNOTESTHATDONOTAPPLYTOTHIS PROJECT.N-001Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884415.050Landers, Jo6 Service Center Rd #2Northampton, MA 0106006/09/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNPV SITE LAYOUT LEGEND * EXISTING DIMENSIONS ARE APPROX.CONFIRM ALL DIMENSIONS SHOWN PV ARRAY LAYOUTSQUARE FOOTAGE CALCULATIONS ROOF REFERENCE SQUARE FOOTAGE TOTAL PERCENTAGE AZIMUTH ANDTILTTABLE SECTION #AZIMUTH ROOF PITCH / TILT EXISTING ROOF ADDRESS kW PHOTOVOLTAIC PLANSSECTION 1 ROOF ACCESS POINT SITE ACCESS GATE ACCESS SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP RA SA GA NOTE: ALL ELECTRICAL LAYOUT DETAILS ON SHEET E-100 NORTH SECTION 1 4'-0"RA RA DRIVEWAYSERVICE CENTER RD2015 IFC ROOF ACCESS REQUIREMENTS VOLTAIC MODULE DIMENSIONS ARE ON SHEET E-001 LOCATED ON SHEET E-100. A. B. C. THIS SHEET REPRESENTS THE SOLAR MODULE LAYOUT ON ROOFTOP. SHADED DASHED LINE NEAR PERIMETER OF STRUCTURE EXTERIOR IS PHOTOVOLTAIC MODULES ARE SCALED IN PLAN VIEW AND MAY NOTBE AN ACCURATELY SCALED REPRESENTATION OF THE ACTUAL SCALEAND GEOMETRY OF THE PHOTOVOLTAIC MODULE. ACTUAL PHOTO- FOR THE PURPOSE OF CLARITY, ALL ELECTRICAL LAYOUT DETAILS ARE AN APPROXIMATE REPRESENTATION OF THE EXTERIOR WALL LOCATION PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER SCALE: 1/16” = 1’0” @ SHEET SIZE A3 4576 SECTION-1 808 17.66% 215 2°SECTION-1 QTY 35 Q-Cells Q.PEAK DUO L-G8.2 430 MODULES QTY 1 GENERAC PWRcell XVT076A03 INVERTER PV-100RValley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884415.050Landers, Jo6 Service Center Rd #2Northampton, MA 0106006/09/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESS* EXISTING ROOF DIMENSIONS ARE APPROX.CONFIRM ALL DIMENSIONS SHOWN RACKING LAYOUTRACKING BILL OF MATERIALS (BOM) COMPONENT QTY MODEL LENGTH PV RAIL 1 PV RAIL SPLICE 1 PV RAIL 2 PV RAIL SPLICE 2 RAILTOROOFATTACHMENT EXISTING ROOF CONSTRUCTION COMPONENT TYPE ROOF STRUCTURALCONSTRUCTION ROOFING COVERING RACKING MAX PSF ADDRESSAPN kW PHOTOVOLTAIC PLANSFRAMING INFO NORTH 1 1 1 1 1 1 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 27'-5"42'-712"SHEETNOTES BYTHEBALLASTEDMOUNTINGMANUFACTURER. BAYLOCATIONS,QUANTITYOFBALLASTBLOCKSINEACHBAY,AVERAGEANDMAXIMUMPOUNDSPERSQUAREFOOT,ROOFANCHORLOCATIONSIFREQUIREDSHALLBEDETERMINEDANDVERIFIEDBYALLMANUFACTURERGUIDELINESANDRECOMMENDATIONSASWELLASSTRUCTURALENGINEERING C.ANYROOFANCHORATTACHMENTPOINTSIDENTIFIEDASNECESSARYBYTHEMANUFACTURERORSTRUCTURALSHALLBEINSTALLEDINACCORDANCEROOFANCHORMANUFACTURESDETAILEDINSTRUCTIONS. SECTION 1 PVARRAYTAGSECTION#MODULEGROUP ROOFATTACHMENTPOINT BALLASTRACKINGSYSTEMW/BLOCKNUMBER # PVMODULE PVRACKINGLEGEND A.ROOFSLOPESSHALLNOTEXCEEDTHEMAXIMUMRECOMMENDED B.BALLASTEDRACKINGCONFIGURATIONINCLUDINGBALLASTBLOCK ENGINEERINGWITHTHEBALLASTANDTHE SCALE: 1/16” = 1’0” @ SHEET SIZE A3 Metal Building with I Beams & Purlins 16" O.C 2"x10" @ MAX 16" OC MEMBRANE 3.2 PSF QTY 35 Q-Cells Q.PEAK DUO L-G8.2 430 MODULES QTY 1 GENERAC PWRcell XVT076A03 INVERTER S-100Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884415.050Landers, Jo6 Service Center Rd #2Northampton, MA 0106006/09/2021SUBMIT FOR PERMIT SHEET NOTES RELEASEREVDATE NAME ADDRESSAPNPV RACKING LEGEND 21SCALE: NTS 3 4 A.THESE NOTES APPLY TO RAFTER ROOF CONSTRUCTION. B.THE ROOF STRUCTURE CONFORMED TO BUILDING CODEREQUIREMENTS AT THE TIME IT WAS BUILT. C.STRAND BOARD OR PLYWOOD. 1X SKIP SHEATHING ISACCEPTABLE. D.THE SOLAR ARRAY DISPLACES ROOF LIVE LOADS (TEMPORARYCONSTRUCTION LOADS) THAT THE ROOF WAS ORIGINALLY DESIGNED TO CARRY. E.IF THE ROOF COVERING IS SHINGLES; IT SHALL BE NO MORETHAN TWO LAYERS.(SHOWN) F.IF ROOF COVERING IS TILE; ITS A SINGLE LAYER. ALL TILES ONPLANE OF PV COMPONENTS ARE SECURE. (NOT SHOWN IN DETAIL) G.THE ROOF STRUCTURE IS STRUCTURALLY SOUND, WITHOUTSIGNS OF ALTERATIONS OR SIGNIFICANT STRUCTURALDETERIORATION OR SAGGING. H.THE PV MODULES ARE PARALLEL WITH THE ROOF SURFACE. I.AND THE ROOF SURFACE. (SEE TABLE OF DIMENSIONS "H1") J.UPSLOPE ANCHOR SPACING MAY VARY FROM LISTED TABLES.STANCHIONS CAN BE PLACED NO CLOSER THAN 24" O.C. K. # SCALE: NTS SCALE: NTSSCALE: NTS SECTION ELEVATIONSTABLE OF COMPONENTS COMPONENT MODEL 1 PV RAIL TYPE 1 2 PV RAIL SPLICE TYPE 1 3 PV RAIL TYPE 2 4 PV RAIL SPLICE TYPE 2 5 STANCHION 6 FLASHING 7 MID CLAMP 8 END CLAMP EXISTING ROOF CONSTRUCTION COMPONENT TYPE MEAN ROOF HGT MAX ROOFING COVERING * DETAILS IN SECTION OR SIDE VIEW ROOF RACKING RAIL SPLICE ROOFRACKING STANCHIONW/ RETRO FIT FLASHING SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP ADDRESS kW PHOTOVOLTAIC PLANSN/A L. DETAILS SHOWN ARE A REPRESENTATION OF EXISTING ROOFCONDITIONS. ACTUAL FIELD CONDITIONS MAY VARY. DETAILSARE SHOWN FOR DIAGRAM USE ONLY. REFER TO TABLES FORDESIGN CRITERIA. ALL PLUMBING AND ROOF VENTS SHALL NOT BE OBSTRUCTEDBY PV MODULES AND EQUIPMENT. M. ROOF RACKING RAIL TABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS PURLINPROFILEHS1 HS2ROOFPITCH HS3MAXPURLINSPAN HS4PURLINSPACING I-BEAMTYPEGIRDERMAXSPAN H2PARAPETWALLHGT.ABOVEROOF D1MODULEHORIZONTALLENGTH D2SPACINGBETWEENMODULEROWS NOTE:DIMENSIONSINDICATEDINTABLEOFDIMENSIONSANDCALLOUTSMAYNOTBEINDICATEDORREPRESENTEDONDETAILDRAWING .7 64.5 LBracket,2”x3” Bolt,Carriage3/8”x1” Nut,SerratedFlangeHex,3/8” Strut,15/8”x15/8” Nut,Strut3/8”x1” Bolt,SerratedFlangeHex,3/8” A B C D E F 26.5" 18.25" 39" 64.5" TTCHDGRGDCOGURTOTOOLORMORORMTO Q.PEAK DUO L-G8 92 1329.4 sq.ft May 25, 2021 D1 BALLAST BLOCKS FINISHED ROOFPV MODULE,BY OTHERS 2X10 @ 16" OC I BEAM @ 14' OC 9.61" STANCHION DETAIL MODULE ARRAY 1: I BEAM AND PURLINS - LANDSCAPE STANCHION SPACING DETAIL EXPLODED STANCHION DETAIL ECOLIBRIUM SOLAR 2+ NONE NO PENETRATION 29'-4"2°14'2"40.6" 1'-7" 22' MEMBRANE N/A 16'S-200 N/A ECOLIBRIUM PRODUCT ECOLIBRIUM PRODUCT Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884415.050Landers, Jo6 Service Center Rd #2Northampton, MA 0106006/09/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNPV SYSTEM MAXIMUM VOLTAGE (MODULE VocMAX) DATA SOURCE SOLARABCS.ORG/ABOUT/PUBLICATIONS/REPORTS/ EXPEDITED-PERMIT/MAP/ EXTREME MIN. STCTEMPERATURE CORRECTEDTEMPERATURE MFR. PMAX TEMPCOEFFICIENT[-0.#%/C] * 100 FORMULA CORRECTEDTEMP.COEFFICIENT MODULE Voc[VDC] TEMPERATURECORRECTEDOPEN CIRCUITVOLTAGE - =*= +*=EQUIP. CALCULATIONSPV MODULE #1 SPECIFICATIONS MANUFACTURER MODEL NUMBER WEIGHT Ibs DIMENSIONS L" x W" x D"/ PEAK POWER @ STC (Pmax)WATTS Voc (OPEN-CIRCUIT VOLTAGE)VOLTS DC Vmp (MAX-POWER VOLTAGE)VOLTS DC isc (SHORT-CIRCUIT CURRENT)AMPS imp (OPERATING CURRENT)AMPS MFR. Voc TEMP COEFFICIENT %/K MAX SERIES FUSE RATING AMPS TEMP. CORRECTED Voc VOLTS DC DC/DC OPTIMIZER (IF APPL.) MANUFACTURER MODEL NUMBER WEIGHT Ibs RATED OUTPUT isc AMPS MAX OUTPUT VOLTAGE VOLTS MAX INPUT VOLTAGE Voc VOLTS DC COMBINER / DISCONNECT #1 MANUFACTURER MODEL NUMBER OCPD (DISCONNECT TYPE) WEIGHT Ibs NEMA RATING LOCATION OF COMPONENTDC INPUT SERIES FUSE RATING FOR PV MODULES AMPS (OCPD) QUANTITY OF PV SOURCE CIRCUITS QTY MAX PV MODULE Voc VOLTS DC MAX # OF MODULES IN CIRCUIT QTY MAX ALLOWED INPUT VOLTAGE VOLTS DC MAX INPUT FUSE/BREAKER RATING AMPSDC OUTPUT MAX CIRCUIT OUTPUT CURRENT AMPS MAX CONT. OUTPUT CURRENT AMPS STRING INVERTER #1 SPECIFICATIONS MANUFACTURER MODEL NUMBER NOMINAL POWER RATING WATT AC WEIGHT Ibs.DC INPUT Max INPUT DC VOLTAGE VOLTS DC Min. MPPT VOLTAGE RANGE VOLTS DC Max. MPPT VOLTAGE RANGE VOLTS DC Max INPUT CURRENT AMPS MPPT QTY INTEGRATED DC DISCONNECT COMPLY W/NEC 690.17INTEGRATED AC DISCONNECTAC OUTPUT NOMINAL VOLTAGE OUTPUT VOLTS AC MAX OVERCURRENT PROTECTION (OCPD)AMPS MAX. OUTPUT CURRENT AMPS - MAX AC SUB-PANEL #1 (IF APPL.) NEW OR EXISTING MAKE / MODEL TYPE OF PANEL NUMBER OF POLES P NEMA RATING BUSS BAR RATING AMPS SUB-PANEL MAIN BREAKER AMPS MAIN SERVICE PANEL P.O.C. BREAKER AMPS AMPS MAX ALLOWABLE SOLAR CURRENT AMPS PV BACKFEED BREAKER #1 AMPS (Imax) AMPS (Imax) MAIN SERVICE PANEL (IF APPL.) NEW OR EXISTING ELECTRICAL SERVICE BUSS BAR RATED CURRENT AMPS MAIN BREAKER RATED CURRENT AMPS AMPS AMPS AMPS (Imax) AMPS (Imax) ADDRESSTHICK WATTSMAX. AC APPARENT POWER kW PHOTOVOLTAIC PLANSDC COMBINER / DISCONNECT #2 (IF APPL.) MANUFACTURER MODEL NUMBER OCPD (DISCONNECT TYPE) WEIGHT Ibs NEMA RATING LOCATION OF COMPONENT DC INPUT SERIES FUSE RATING FOR PV MODULES AMPS (OCPD) QUANTITY OF PV SOURCE CIRCUITS QTY MAX PV MODULE Voc VOLTS DC MAX # OF MODULES IN CIRCUIT QTY MAX ALLOWED INPUT VOLTAGE VOLTS DC MAX INPUT FUSE/BREAKER RATING AMPSDC OUTPUT MAX CIRCUIT OUTPUT CURRENT AMPS MAX CONT. OUTPUT CURRENT AMPS AMPS MANUFACTURER MODEL NUMBER OCPD (DISCONNECT TYPE) WEIGHT Ibs NEMA RATING LOCATION OF COMPONENTDC INPUT QTY MAX PV MODULE Voc MAX # OF MODULES IN CIRCUIT QTY MAX ALLOWED INPUT VOLTAGE AMPSDC OUTPUT MAX CIRCUIT OUTPUT CURRENT AMPS MAX CONT. OUTPUT CURRENT SERIES FUSE RATING FOR PV MODULES AMPS (OCPD) QUANTITY OF PV SOURCE CIRCUITS VOLTS DC VOLTS DC MAX INPUT FUSE/BREAKER RATING DC COMBINER / DISCONNECT #3 (IF APPL.) QUANTITY STRING INVERTER #2 SPECIFICATIONS (IF APPL.) AMPS - MAX MANUFACTURER MODEL NUMBER NOMINAL POWER RATING WATT AC WEIGHT Ibs.DC INPUT Max INPUT DC VOLTAGE VOLTS DC Min. MPPT VOLTAGE RANGE VOLTS DC Max. MPPT VOLTAGE RANGE VOLTS DC Max INPUT CURRENT AMPS MPPT QTY INTEGRATED DC DISCONNECT COMPLY W/NEC 690.17INTEGRATED AC DISCONNECTAC OUTPUT NOMINAL VOLTAGE OUTPUT VOLTS AC MAX OVERCURRENT PROTECTION (OCPD)AMPS MAX. OUTPUT CURRENT WATTSMAX. AC APPARENT POWER QUANTITY INVERTER(S) INVERTER(S) AC COMBINER #1 (SOLAR LOAD CENTER) MANUFACTURER MODEL NUMBER RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING MAIN BREAKER SIZE TOTAL INPUT CURRENT AMPS NUMBER OF BRANCH CIRCUITS AMPS CIRCUITS AC DISCONNECT #1 MANUFACTURER (IF APPL.) AMPS MODEL NUMBER DISCONNECT DEVICE TYPE RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING FUSE RATING AMPS TOTAL INPUT CURRENT QUANTITY AC DISCO.(S) AC DISCONNECT #2 MANUFACTURER (IF APPL.) AMPS MODEL NUMBER DISCONNECT DEVICE TYPE RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING FUSE RATING AMPS TOTAL INPUT CURRENT QUANTITY AC DISCO.(S) PV BACKFEED BREAKER #2 PV BACKFEED BREAKER #3 PV BACKFEED BREAKER #4 AMPS (Imax) AMPS (Imax) AC COMBINER #2 (SOLAR LOAD CENTER) MANUFACTURER MODEL NUMBER RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING MAIN BREAKER SIZE TOTAL INPUT CURRENT AMPS NUMBER OF BRANCH CIRCUITS AMPS CIRCUITS AMPS (Imax) AMPS (Imax) AMPS (Imax) SUM OF EXISTING CIRCUIT BREAKERS AMPS (Imax) MAX ALLOWABLE SOLAR CURRENT 100% MAX ALLOWABLE SOLAR CURRENT 120% PV BACKFEED BREAKER #1 PV BACKFEED BREAKER #2 PV BACKFEED BREAKER #3 PV BACKFEED BREAKER #4 ALT. ENERGY BACKFEED BREAKER (IF APPL.) SUM OF EXISTING CIRCUIT BREAKERS BATTERYSPECIFICATIONS Years/MWh10/7.56Modulesion - Warranty:Li Years10:ElectronicsWarranty UL9540,UL1973,UL1642CSA-22.2Compliance -™EbusDCNanogridRCommunicationProtocol (kg)b,leight(Installed)W (kg)b,leight(Enclosure)W (kg)b,lionmodule) - Weight(Li VDC46.8ModuleVoltage -6BatteryModules (mm)n,Ix22x10(1725x560x235)68Dimensions mt,f(3000)9834,MaximumInstallationAltitude C)ᵒF,(ᵒ -- C)ᵒ,(FᵒngeOperatingTemp.Ra %96.5TripEfficiency-Round VDC420-360EbusVoltage:Input/OutputR kWutesPower:2min kWPower:60minutes kW6.7Power:RatedContinuous kWhUsableEnergy sUnitSpecification - Generac -PWRCell18 18.0 9.0 50 14-122,(-10-50) RecommendedTemp.Range 41 104,(5 40) 55,(25) 111,(50) 441,(200) Q-Cells EatonDG222URB1Q.PEAK DUO L-G8.2 43055.181.9 x 40.6 x 1.38 NON-FUSIBLE DISCONNECT120/24043049.3341.7010.83 60 53.77 10.31 3R2 N/A32-0.220.0 GeneracPV Link APKE000107.38420420 GENERACPWRcell XVT076A03 760062.7 420360420202YesNO 24076004032 -20 25 -45 -0.2%0.09 1 1.09 49.33 53.77 1 E-001EXISTING120/240V Single Phase200200 04040 Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884415.050Landers, Jo6 Service Center Rd #2Northampton, MA 0106006/09/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSDC WIRE AND CONDUIT SIZING CHART [SEE SHEET E-003 FOR THREE LINE DIAGRAM] TAG CIRCUITORIGIN CIRCUIT CONDUCTORSPECIFICATIONS REQUIRED CONDUCTOR AMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILLDERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK TEMPRATING TRADESIZE AMPACITYPER 310.16 MAXCURRENT690.8 (A)(1) CONT.OPERATION690.8 (B)(1) REQUIREDAMPACITY CIRCUITENVIRONMENT AMBIENTTEMP. HGT.ABOVEROOF (in) TEMP.ADDER PER310.15(B)(2)(c) OPERAT.TEMP. AMPACITYCORRECTION310.15(B)(2)(a) # OFUNGRND.COND. AMPACITYCORRECTION310.15(B)(3)(a) COND.AMPACITY TEMP.DERATING CONDUITFILLDERATINGXXX=XX=CORRECTEDAMPACITY REQUIREDAMPACITY <CORRECTEDAMPACITY DC1 XXX=XX=< DC2 XXX=XX=< DC3 XXX=XX=< DC4 XXX=XX=< DC5 XXX=XX=< AC WIRE AND CONDUIT SIZING CHART [SEE SHEET E-003 FOR THREE LINE DIAGRAM] TAG CIRCUIT ORIGIN CIRCUITDESTINATION CONDUCTORSPECIFICATIONS REQUIRED CONDUCTORAMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILLDERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK TEMPRATING TRADESIZE AMPACITYPER 310.16 CONT.OPERATION690.8 (B)(1)X =REQUIREDAMPACITY CIRCUITENVIRONMENT AMBIENTTEMP. HGT.ABOVEROOF (in) TEMP.ADDER PER310.15(B)(2)(c) OPERAT. AMPACITYCORRECTION310.15(B)(2)(a) # OFUNGRND.COND. AMPACITYCORRECTION310.15(B)(3)(a) COND.AMPACITY X TEMP.DERATING X CONDUITFILLDERATING =CORRECTEDAMPACITY REQUIREDAMPACITY <CORRECTEDAMPACITY AC1 X =X X =< AC2 X =X X =< AC3 X =X X =< AC4 X =X X =< AC5 X =X X =WIRE AND COND. CALCS.1. ANY CONDUCTOR LENGTH UNDER 50' DOESN'T REQUIRE VOLTAGE DROP CALCULATIONS DEEMED QUESTIONABLE TO PREVENT ISSUES RELATED TO USING CONDUCTORS THAT ARE IMPROPERLY SIZED.3.4.CEC/NEC 310.15(A)(2) (AS APPLICABLE) WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE HIGHER AMPACITY SHALL BE PERMITTED TO BEUSED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO 10'-0" (3 METERS) OR 10% OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICHEVER IS LESS. WHEN LESS THAN 10'-0" OR 10% OF THE CIRCUIT LENGTH; THE LESSER AMPACITY MAY BE USED. PV DC WIRING AC WIRING 2.BECAUSE WE ARE UNABLE TO DETERMINE THE EXACT PATH THE INSTALLER WILL RUN CONDUCTORS; WORST CASE SCENARIOS, ROUNDING UP SIZES OF CONDUCTORS THAT ARE EQUIPMENT GROUNDGREEN OR BARE, OR GREEN/YELLOWEQUIPMENT GROUND GREEN OR BARE, OR GREEN/YELLOW TYPICALLY NEGATIVEWHITE OR GRAY(NEUTRAL)WIRING METHODS IN THESE CALCULATIONS DON'T EXCEED 1000 VOLTSGROUNDED CONDUCTOR.GROUNDED CONDUCTORWHITE OR GRAY UNGROUNDED CONDUCTOR(S).TYPICALLY POSITIVE ANY COLOR OTHER THAN GREEN OR WHITE/GRAY UNGROUNDED L1 AND L2 ANY COLOR OTHER THAN GREEN OR WHITE/GRAY ALLOWED. CONVENTION IS RED FOR GROUNDED SYSTEMSCONDUCTOR(S) HOT:CONVENTION IS L1 BLACK RED (+) AND BLACK (-) FOR UNGROUNDED SYSTEMSCONVENTION IS L2 RED WIRE AND CONDUCTOR NOTES APN ADDRESS kW PHOTOVOLTAIC PLANSAC6 X =X X =< AC7 X =X X =< AC8 X =X X =< AC9 X =X X =< AC10 X =X X = < < DC6 XXX=XX=< DC7 XXX=XX=< DC8 XXX=XX=< #OFCOMBINEDPARALLELSTRINGS DESTINATION QTY INPARALLEL &MATERIAL QTY INPARALLEL &MATERIAL lsc (AMPS)ORCOMPONENT(AMPS) MAX INV. OUTPUTCURRENT (AMPS)ORCOMPONENT(AMPS) PV MODULE PV LINK (1) CU 90 #12 AWG 30 10.83 1 1.25 1.25 16.92 ROOFTOP 35 >7/8"0 35 0.96 2 N/A 30 0.96 1.0 21.3 16.92 21.3 PV LINK Y-CONNECTOR (1) CU 90 #10 AWG 40 8 1 1 1.25 10 ROOFTOP 35 >7/8"0 35 0.96 12 N/A 40 0.96 1.0 38.4 10 28.4 Y-CONNECTOR JUNCTION BOX (1) CU 90 #10 AWG 40 24 1 1 1.25 30 ROOFTOP 35 >7/8"0 35 0.96 4 N/A 40 0.96 1.0 30 30 14.2 JUNCTION BOX INVERTER (1) CU 90 #10 AWG 40 24 1 1 1.25 30 ATTIC 35 IN ATTIC 0 35 0.96 4 0.8 40 0.96 0.8 30 30 30.72 BATTERY INVERTER (1) CU 90 #10 AWG 40 27.24 1 1 1.25 34.05 EXT WALL 35 N/A 0 35 0.96 2 1.0 40 0.96 1.0 38.4 27.24 38.4 47.0 0.94 0.94 0.96 0 0 N/A N/A N/A 0 0.94 40.0 50.0 47.0 61.1 1.0 1.0 0.94 0.94651.033535INT/EXT WALL5050 (1) CUAUTO TRANSFER SWITCH INVERTER AC DISCONNECT (1) CU 75 #8 AWG 50 1.25 32.0 40.0 INT/EXT WALL 35 35 3 1.0 50 0.94 1.0 47.0 40.0 AC DISCONNECT PRODUCTION METER (1) CU 75 #8 AWG 50 1.25 32.0 40.0 INT/EXT WALL 35 N/A 0 35 0.94 3 1.0 50 0.94 1.0 47.0 40.0 47.0 PRODUCTION METER EXISTING SERVICE PANEL (1) CU 75 #8 AWG 50 1.25 32.0 40.0 INT/EXT WALL 35 35 3 1.0 50 47.0 INVERTER AUTO TRANSFER SWITCH (1) CU 75 #6 AWG 65 N/A 61.1 EXISTING SERVICE PANEL 90 #3/0 AWG 225 N/A 200 35 3 1.0 225 0.96 200 E-002216 WIRE COLOR CODING (2020) NEC SECTIONS 250.119 & 200.6 Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884415.050Landers, Jo6 Service Center Rd #2Northampton, MA 0106006/09/2021SUBMIT FOR PERMITAUTO TRANSFER SWITCH METER SOCKET (1) CU 90 #3/0 AWG 225 N/A 200 200 INT/EXT WALL 35 N/A 0 200 INT/EXT WALL 35 N/A 0 35 0.96 2 1.0 225 0.96 1.0 216 1.0 216 200 216 RELEASEREVDATE NAME ADDRESSTHREE LINE DIAGRAMAPN ADDRESS kW PHOTOVOLTAIC PLANSLEGENDEQUIPMENT TABLE QTY COMPONENT 1 PV MODULES 2 3 DC DISCONNECT 4 MODULE LEVEL RSD DEVICE 5 JUNCTION BOX 6 RAPID SHUTDOWN 7 AC/DC INVERTER 8 EMERGENCY DISCONNECT 9 AC DISCONNECT (FUSIBLE) 10 AUTO TRANSFER SWITCH 11 12 BATTERY 13 14 15 EXISTING UTILITY METER NOTE: EQUIP TAGS MAY NOT BE IN SEQUENTIAL ORDER, N/A USED TAG SEE SHEET E-001 FOR ADDITIONAL ELECTRICAL SPECIFICATIONS ELECTRICAL NOTES UNGROUNDED PV SYSTEMS:•INVERTERS, MODULES, AND DC COMPONENTS MUST BE LISTEDFOR USE IN UNGROUNDED SYSTEMS, TYPICALLY TRANSFORMER-LESS (TL) •OCPD'S WHERE NECESSARY MUST HAVE DISCONNECTING MEANS. •PV SOURCE CIRCUITS MUST BE EITHER PV WIRE AND LISTED FOR WET LOCATIONS OR JACKETED MULTI-CONDUCTOR CABLESINSTALLED IN RACEWAY. •THE AC SIDE IS STILL GROUNDED ON THE NEUTRAL CONDUCTOR. •REQUIRE EQUIPMENT GROUNDING BUT DOES NOT HAVE SYSTEM GROUNDING; NO DC CURRENT-CARRYING CONDUCTOR ISCONNECTED TO GROUND. THESE CONDUCTORS ARE COLORCODED DIFFERENTLY THAN GROUNDED PV SYSTEMS. AC/DC ELECTRICAL NOTES: •ALL OVERCURRENT PROTECTION DEVICES (OCPDs) MUST BERATED FOR 600 VOLTS ON THE DC / PV POWER SIDEOF THE INVERTER.•EXTERIOR ENCLOSURES TO BE NEMA TYPE 3R OR BETTER. •ALL CONDUIT AND CONDUIT CONNECTIONS SHALL BE RATED FOR WET AND DAMP LOCATIONS WHEN APPLICABLE. INTERCONNECTION NOTES: •705.12(B)(4) CIRCUIT BREAKERS MUST BE SUITABLE FORBACKFEEDING. NEC INFORMATIONAL NOTE: FUSED DISCONNECTS, UNLESS OTHERWISE MARKED,ARE SUITABLE FOR BACKFEEDING. •690.13(F)(2) DEVICES MARKED WITH "LINE” AND “LOAD” SHALLNOT BE PERMITTED FOR BACKFEED OR REVERSE CURRENT •705.12(B)(5) CIRCUIT BREAKERS BACK FEED FROM UTILITYINTERACTIVE INVERTERS (ANTI-ISLANDING, UL 1741 CERTIFIED) DC CONDUCTOR TAG AC CONDUCTOR TAG EQUIPMENT TAG AC# DC# GROUND CONDUCTOR TAGGND STRING MODULE QTY INVERTER# BACK-FEED SOLAR BREAKER: CONDUCTOR TABLE TAG QTY*SIZE TYPE DC1 DC2 DC3 DC4 DC5 AC1 AC2 AC3 AC4 AC5 GROUND SIZE TYPE CONDUIT TABLE AC6 AC7 AC8 AC9 AC10 DC6 DC7 DC8 16 AC DISCONNECT (INDEPENDENT) • * INCLUDES GROUND & CURRENT CARRYING CONDUCTORS G G DC3 DC4 5 THEBATTERYWILLONLYBECHARGEDBYPV. THEBATTERYDISCHARGESTOTHEGRIDONLYIFREQUESTEDBYTHEGRIDVIACONNECTEDSOLUTIONS. THEBATTERYWILLDISCHARGETOONSITELOADS. DC5 8 GG 3 6 INVERTER NAMEPLATE RATING 7600W / EMERGENCYDISCONNECT DC 240V 7 AC4 AC1ACN G L2 L1 GNL2L1 GNL2L1 N G L2 L1 N G L2 L1 11 AUTO TRANSFER SWITCH L1 L2 N L1L2 N G L1L2N G 50APV N G L2 L1 AC2 LOCATED EXTERIOR SOLAR GENERATION (LOAD) BOTTOM LUGS TO TOP LUGS TO UTILITY (LINE) MA SMART GENERATION METER RSD SWITCHEMERGENCY G EGC R3METER NEMA LOCATED EXTERIOR ON WALL NEAR V 240A 60APPROACH TO RESIDENCE SYSTEM DISCONNECT VISIBLE FROM READILY ACCESSIBLE OPEN BLADE AC L2 L1 L2 L1 GG NN 9 AC3 G N BUSRATING200A 15 GEC PWRC -12 ell + 10 M 16 AC5 AC6 1 1 1 1 DC1 DC1 5MODULES 6MODULES 6MODULES MC-4Y-CONNECTORS 4 4 4 4 2 2 1 1 1 DC1 MODULENAMEPLATERATING430WDC2 4 4 4 2 1 1 1 1 1 DC1 DC1 DC1 EGC MODULES 6MODULES 4 4 4 4 4 2 2 2 6 MODULES6 PRODMETERMASMARTGENERATIONMETER Generac PWRcell 18kWh Battery 40A MAIN C/BRATING200A 35 Q-Cells Q.PEAK DUO L-G8.2 430 6 PV Link APKE00010 N/A INTEGRATED IN INV 35 SnapRS Device 1 Snapnrack 242-0114 N/A INTEGRATED IN INV 1 GENERAC PWRcell XVT076A03 1 IMO SI32-PEL64R-2 1 6 Eaton DG222URB INV 1 CXSW200A3 2 6 INV 1 3 6 INV 1 4 6 INV 1 1 1 1 1 0 5 6 INV 1 1 6 5 INV 1 1 120/240V - 1 40A 2 #12 AWG PV Wire #6 AWG N/A Open Air 13 #10 AWG PV Wire #6 AWG N/A Open Air 0 5 #10 AWG PV Wire #6 AWG N/A Open Air NEW MAIN SERVICE PANEL 5 #10 AWG THWN-2 #8 AWG 1/2 inch EMT EXISTING MAIN SERVICE PANEL 200A BUS/200A MB 3 #10 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #6 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #3/0 AWG THWN-2 #4 AWG 2 inch EMT NO CENTER-FED MAIN BREAKER. PANEL CONFIGURED PER NEC 705.12(B)(2)(3)(b)E-003DC/DC OPTIMIZER Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884415.050Landers, Jo6 Service Center Rd #2Northampton, MA 0106006/09/2021SUBMIT FOR PERMIT3 #3/0 AWG THWN-2 N/A 1-1/2 inch EMT RELEASEREVDATE NAME ADDRESSAPNELECTRICAL LAYOUTEQUIPMENT GROUNDING 1. METAL PV MODULE FRAMES MUST BE CONNECTED TO THE EGC(EQUIPMENT GROUNDING CONDUCTOR). 1.1. WEEBS MAY BE USED IN LIEU OF MODULE GROUND CLAMPSOR LUGS, WITH APPROVAL OF AHJ AND RACKING MFG. WEEBSARE ONE TIME USE ONLY. SEE "we-llc.com" FOR RACKINGSPECIFIC WEEB, INSTALL INSTRUCTIONS, AND UL 2703 CERT. 1.2. FOR "LAY-IN" LUG MODULE GROUNDING; CORRECTHARDWARE OF PROPER METAL MATERIAL TO AVOIDCORROSION MUST BE USED. TYPICALLY DIRECT BURIAL RATED,TINNED, OR STAINLESS STEEL. GROUNDING LUGS MUST BEATTACHED AT MARKED LOCATION ON EACH MODULE. 2. THE EGC (EQUIPMENT GROUNDING CONDUCTOR) IS USED TOBOND ALL NON-CURRENT CARRYING CONDUCTORS AND EXPOSEDMETAL PARTS THAT MIGHT COME INTO CONTACT WITHCURRENT-CARRYING CONDUCTORS, INCLUDING THE FOLLOWING: 2.1. PV MODULES FRAMES, ARRAY MOUNTING RACKING; THEMETAL CHASSIS OF EQUIPMENT SUCH AS INVERTERS,DISCONNECTS, METERS, JUNCTION BOXES AND COMBINERBOXES; AND METAL CONDUIT HOLDING CIRCUITS > 250 VOLTSTO GROUND PER NEC 250.97 3. THE GEC (GROUNDING ELECTRODE CONDUCTOR) IS THECONDUCTOR USED TO CONNECT THE GE OR GE SYSTEM TO THESYSTEM GC, TO THE EGC, OR TO BOTH. 4. THE GE (GROUNDING ELECTRODE) IS A CONDUCTING OBJECT,OFTEN A ROD, RING, OR PLATE ESTABLISHING A DIRECTCONNECTION TO EARTH. THE AC SYSTEM GROUND IS EXISTING,USUALLY AT THE EXISTING MAIN PANEL AND/OR UTILITY METER.THE GROUND CAN ONLY OCCUR IN ONE PLACE AND MUST NOT BEDUPLICATED IN SUB-PANELS OR ANYWHERE ELSE ON AC SIDE. ADDRESS kW PHOTOVOLTAIC PLANSSPMATSINV BATT ACPRSEBNORTH JB ELECTRICAL SYMBOL LEGEND AC DISCONNECT DC DISCONNECT DC COMBINER BOX AUTO TRANSFORMERCB DC AC ATFEBEMERGENCY BATTERYDISCONNECT SERVICE PANELSP RAPID SHUTDOWN BATTERY RS AC COMBINERACCBATTINV#DC/AC STRING INVERTERCLPCRITICAL LOADS PANEL SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP PERFORMANCE METER UTILITY METER P MXFMR TRANSFORMERJUNCTION BOXJB RSD RAPID SHUTDOWNCIRCUIT BREAKER CB ATS AUTO TRANSFER SWITCH SCALE: 1/16” = 1’0” @ SHEET SIZE A3QTY 35 Q-Cells Q.PEAK DUO L-G8.2 430 MODULES QTY 1 GENERAC PWRcell XVT076A03 INVERTER E-100PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER.Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884415.050Landers, Jo6 Service Center Rd #2Northampton, MA 0106006/09/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNSTANDARD PLACARDS ADDRESS kW PHOTOVOLTAIC PLANSSHEET NOTES1SCALE:1/2" = 1'-0"CONDUIT, RACEWAY, J-BOX, AND PULL BOXES 2 3 5 6 8 SCALE:1/4" = 1'-0"9 10 4 1.PLACE ON CONDUIT AND/OR RACE WAYS EVERY 10' (60"), 12"FROM BENDS, 12" ABOVE AND BELOW PENETRATIONS. 2.CODE REFERENCE: NEC 690.31(G)(3)3.MINIMUM OF 1 1/8" x 5 3/4" 4.FONT: 3/8" AND .8 WIDTH FACTOR. 5.REFLECTIVE WHITE LETTERS ON A RED BACKGROUND. J-BOX, DC COMBINER, AND DC DISCONNECT WARNING: ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED SCALE:1/4" = 1'-0" 1.ONLY FOR UNGROUNDED SYSTEMS. 2.PLACED ON ALL ENCLOSURES WITH UNGROUNDED CIRCUITSOR DEVICES WHICH ARE ENERGIZED AND MAY BE EXPOSEDDURING SERVICE. 3.MINIMUM OF 3" x 10 1/2" 4.FONT: 3/8" 5.WHITE LETTERS ON A RED BACKGROUND. NON-LOAD BREAK DC COMBINER / J-BOX WARNING: ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION SCALE:1/2" = 1'-0" 1.PLACED ON DC DISCONNECT(S) AND ON ANYEQUIPMENT THAT STAYS ENERGIZED IN THE OFFPOSITION FROM THE PV SUPPLY. 2.CODE REFERENCE: NEC 690.13(B) 3.MINIMUM OF 3 1/2" x 10" 4.FONT: 3/8" 5.WHITE LETTERS ON A RED BACKGROUND. INVERTER(S)SCALE:1/2" = 1'-0" WARNING: ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED 1.A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL LOCATEDON OR NO MORE THAN 1M (3 FT) FROM THE SWITCH THATINCLUDES THE FOLLOWING: 2. 3. MINIMUM OF 3 1/2" x 10 1/2" 4. FONT: 3/8" WHITE LETTERS ON A RED BACKGROUND. AC AND DC DISCONNECTS PV SYSTEM DISCONNECT 1.PLACE ON ALL AC AND DC DISCONNECTS 2.CODE REFERENCE: NEC 690.13(B) 3.MINIMUM OF 1" x 10 1/2" 4.FONT: 3/8" 5.WHITE LETTERS ON A RED BACKGROUND. SCALE:1/4" = 1'-0"SCALE:1/4" = 1'-0" DC COMBINER BOX 1. 2. USE PLACARD "COMBINER # 1" WHEN MORE THAN 1DC COMBINER IS USED. NUMBER ACCORDING TOTHREE LINE DIAGRAM AND CALCULATIONS. 3. MINIMUM OF 1" x 4" 4. FONT: 3/8" AND .75 TO .8 WIDTH FACTOR WHITE LETTERS ON A RED BACKGROUND. 1.CODE REFERENCE: NEC 690.13(C) 2.USE ON NON-LOAD BREAK RATED DISCONNECTION. 3.MINIMUM OF 1" x 6" 4.FONT: 3/8" AND .8 WIDTH FACTOR 5.WHITE LETTERS ON A RED BACKGROUND. DC DISCONNECTS 1.USE PLACARD ON CUSTOMER GENERATION METER. 2.VERIFY WHICH PLACARD IS REQUIRED WITH AHJ. 3.MINIMUM OF 1" x 4" 4.FONT: 3/8" AND .8 WIDTH FACTOR 5.WHITE LETTERS ON A RED BACKGROUND. SOLAR kWh METER SCALE:1/2" = 1'-0" INVERTER # 1 1.USE PLACARD "INVERTER # 1" WHEN MORE THAN 1INVERTER IS USED. NUMBER ACCORDING TO THREELINE DIAGRAM AND CALCULATIONS. 2.MINIMUM OF 1" x 4" 3.FONT: 3/8" 4.WHITE LETTERS ON A RED BACKGROUND. SCALE:1/2" = 1'-0" USE PLACARD "[AC][DC] DISCONNECT # 1" WHEN MORETHAN ONE DISCONNECT IS USED. NUMBER ACCORDING TOTHREE LINE DIAGRAM AND CALCULATIONS. 11 SCALE:1/4" = 1'-0"MAIN SERVICE PANEL 1.COMBINATION PLACARDS MAY BE USED IN PLACE OF MULTIPLEPLACARDS FOR THE SAME DEVICE. ALL INFORMATION FROMTHE MULTIPLE PLACARDS MUST BE PRESENT. 2.BLACK LETTERS WITH YELLOW BACKGROUND MAY BE USED INPLACE OF THE STANDARD WHITE LETTERS WITH REDBACKGROUND WITH AHJ APPROVAL. 3.ALL INTERIOR AND EXTERIOR DC CONDUIT, ENCLOSURES,RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINERBOXES AND DISCONNECTS ARE MARKED. (NEC 690.31[G], NEC 690.13 & 690.53) 4.THE MARKINGS ON THE CONDUITS, RACEWAYS AND CABLEASSEMBLIES ARE EVERY 10 FEET, WITHIN ONE FOOT OF ALLTURNS OR BENDS AND WITHIN ONE FOOT ABOVE AND BELOWALL PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS ANDBARRIERS. (IFC 605.11.1.4, NEC 690.31[G][3] ) 5.WHERE PV CIRCUITS ARE EMBEDDED IN BUILT-UP, LAMINATEOR MEMBRANE ROOFING MATERIALS IN ROOF AREAS NOTCOVERED BY PV MODULES AND ASSOCIATED EQUIPMENT, THELOCATION OF CIRCUITS SHALL BE CLEARLY MARKED. 6.REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FORTHE ENVIRONMENT. MATERIALS USED FOR MARKING MUST BEWEATHER RESISTANT. UL STANDARD IS RECOMMENDED TODETERMINE WEATHER RATING. UL LISTING OF MARKINGS ISNOT REQUIRED. SEE UL LABELING SYSTEM 969 (UL 969) 7.MARKING CONTENT AND FORMAT: 7.1.ARIAL OR SIMILAR FONT, NON-BOLD. 7.2.MINIMUM 3/8" LETTER HEIGHT FOR HEADERS. 7.3.MINIMUM 1/16" LETTER HEIGHT FOR DATA7.4.CONTRASTING BACKGROUND AND LETTERING. 7.5.ALL CAPITAL LETTERS. 7.6.CONTRASTING SPACE BETWEEN ROWS OF TEXT 7.7.DIMENSIONS OF PLACARDS ARE APPROXIMATE. MAY BE REDUCED AND / OR INCREASED TO UL APPROVEDMANUFACTURED PRODUCT CODE ABBREVIATIONS:NATIONAL ELECTRICAL CODE (NEC)INTERNATIONAL BUILDING CODE (IBC)INTERNATIONAL RESIDENTIAL CODE (IRC)INTERNATIONAL FIRE CODE (IFC)UNDERWRITERS LABORATORY (UL) DO NOT DISCONNECT UNDER LOAD 7 RAPID SHUTDOWN SWITCH RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM THE LABEL SHALL BE REFLECTIVE WITH ALL LETTERS CAPITALIZEDAND HAVING A MINIMUM HEIGHT OF 9.5 MM (3⁄8 IN.),IN WHITE ON RED BACKGROUND. 2. 1/4" = 1'-0"SCALE: 2CODEREFERENCE:NEC690.56(C)(1)(a) 3TITLE:MIN.3/8"BLACKCHARACTERSONYELLOWBACKGROUND,REMAININGCHARACTERSMIN.3/16"INBLACKONWHITEBACKGROUND. 1LOCATENOMORETHAN1mFROMTHESERVICEDISCONNTMEANSTOWHICHTHEPVSYSTEMSARECONNECTEDANDSHALLINDICATETHELOCATIONOFALLIDENTIFIEDRAPIDSHUTDOWNSWITCHESIFNOTATTHESAMELOCATION. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE “OFF” POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. SOLAR ELECTRIC PV PANELS INVERTER(S)P-001QTY 35 Q-Cells Q.PEAK DUO L-G8.2 430 MODULES QTY 1 GENERAC PWRcell XVT076A03 INVERTER Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884415.050Landers, Jo6 Service Center Rd #2Northampton, MA 0106006/09/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNDYNAMIC PLACARDS ADDRESS kW PHOTOVOLTAIC PLANS1.PRIME CONTRACTOR / PERMIT APPLICANT SIGNERIS RESPONSIBLE FOR THE DESIGN ANDSPECIFICATIONS OF THE PHOTOVOLTAIC SYSTEMINSTALLATION. PRIME CONTRACTOR / PERMITAPPLICANT SIGNER WILL BE RESPONSIBLE FORCOLLECTION OF EXISTING ONSITE INFORMATIONREQUIREMENTS TO DESIGN, SPECIFY, AND INSTALLTHE EXTERIOR MOUNTED PORTION OF THEPHOTOVOLTAIC SYSTEM DETAILED IN THISDOCUMENT. 2.ADVANCED SOLAR SOLUTIONS, INC ISRESPONSIBLE FOR APPLYING SUPPLIEDINFORMATION INTO A SET OF PERMIT DRAWINGS.ANY CHANGES TO DRAWINGS ARE SUBJECT TOCONTRACT CONDITIONS BETWEEN THE CLIENTAND ADVANCED SOLAR SOLUTIONS, INC. INACCORDANCE WITH THE REQUIREMENTS OF THEAHJ. RESPONSIBILITY NOTES 1. PLACARD PLACED AT ELECTRICAL SERVICE AND AT THE PVINVERTER AND PV DISCONNECTS IF NOT AT THE SAME LOCATION. 2. MAP PLACARD PROVIDES A DIRECTORY OF THE SERVICEDISCONNECTING MEANS AND PHOTOVOLTAIC SYSTEMDISCONNECTION MEANS. 3. CODE REFERENCE: NEC 690.56(A)(B), 705.10 4. WHITE LETTERS ON A RED BACKGROUND. 5. MINIMUM OF 7 3/4" x 5" 6. FONT: 3/4" "CAUTION", 1/4" "WARNING", 3/16" HEADER,1/8" DATA AND NOTES 7.PLACARD WILL BE PLACED ADJACENT TO THE MAIN SERVICEDISCONNECT IN A LOCATION CLEARLY VISIBLE FROM WHERETHE DISCONNECT IS OPERATED. (IFC 605.11.1.3) SHEET NOTES 1. 2. 3. 4. COMBINATION PLACARDS MAY BE USED IN PLACE OF MULTIPLEPLACARDS FOR THE SAME DEVICE. ALL INFORMATION FROMTHE MULTIPLE PLACARDS MUST BE PRESENT. BLACK LETTERS WITH YELLOW BACKGROUND MAY BE USED INPLACE OF THE STANDARD WHITE LETTERS WITH REDBACKGROUND WITH AHJ APPROVAL. ALL INTERIOR AND EXTERIOR DC CONDUIT, ENCLOSURES,RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINERBOXES AND DISCONNECTS ARE MARKED. (NEC 690.31[E][3], NEC 690.31[E][4] & 690.53) REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FORTHE ENVIRONMENT. MATERIALS USED FOR MARKING MUST BEWEATHER RESISTANT. UL STANDARD IS RECOMMENDED TODETERMINE WEATHER RATING. UL LISTING OF MARKINGS ISNOT REQUIRED. SEE UL LABELING SYSTEM 969 (UL 969) 5.MARKING CONTENT AND FORMAT: 5.1.ARIAL OR SIMILAR FONT, NON-BOLD.5.2.MINIMUM 3/8" LETTER HEIGHT FOR HEADERS. 5.3.MINIMUM 1/16" LETTER HEIGHT FOR DATA 5.4.CONTRASTING BACKGROUND AND LETTERING. 5.5.ALL CAPITAL LETTERS.5.6.CONTRASTING SPACE BETWEEN ROWS OF TEXT 5.7.DIMENSIONS OF PLACARDS ARE APPROXIMATE. MAY BEREDUCED AND / OR INCREASED TO UL APPROVEDMANUFACTURED PRODUCT 6.ANSI Z535.4 PRODUCT SAFETY SIGNS AND LABELS: THISINFORMATIONAL NOTE AND ITS REQUIREMENTS FORPLACARDS MAY BE USED WITH PRIOR APPROVAL OF THE AHJ.MOST NOTABLE DIFFERENCES IS COLOR OF PLACARDS AND USEOF HAND WRITTEN VALUES WITH INDUSTRIAL MARKERS ONSTANDARD PLACARDS WHERE THE VALUE MAY CHANGE AT AFUTURE DATE. I.E. ADDING MODULES AT A FUTURE DATE, ORSTANDARD PLACARD MANUFACTURER INSTALLED ONELECTRICAL COMPONENT. AHJ APPROVAL REQUIRED. (SEENOTE #1 FOR INDIVIDUAL PLACARDS) 1 SCALE:1/4" = 1'-0"2 3 4 1.PLACARD PLACED ON EACH DISCONNECT, IF MORE THAN ONE PRESENT. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. SEE SHEET "E-001 / DC DISCONNECT [#]" 3.CODE REFERENCE: NEC 690.53 4.MINIMUM OF 2 1/2" x 8" OR 5" x 2 1/2" RESPECTIVELY. 5.FONT: 3/8" HEADER, 3/16" DATA 6.WHITE LETTERS ON A RED BACKGROUND. 7.IN SOME CASES TWO LABELS MAY BE REQUIRED. AN INVERTER WITHINTEGRATED DC DISCONNECT UTILIZING TWO MPPT TRACKERS; IF CONFIGURATIONUSES DIFFERENT MODULES. SCALE:1/4" = 1'-0" MAP PLACARD: MAIN SERVICE PANEL AND PV INVERTER (IF NOT SAME LOCATION) SCALE:1/4" = 1'-0"UTILITY METER, SERVICE PANEL, SUB-PANELAC DISCONNECT, AC SUB-PANEL MAXIMUM CIRCUIT CURRENT MAXIMUM VOLTAGE PV SYSTEM DC DISCONNECT ADC PHOTOVOLTAIC SYSTEM DC DISCONNECT MAX. CIRCUIT CURRENT MAXIMUM VOLTAGE ADC VDC 1.PLACARD PLACED ON EACH SOLAR SYSTEM DISCONNECTING COMPONENT. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. SEE SHEET "E-001 / AC DISCONNECT [#]" 3.CODE REFERENCE: NEC 690.54 4.MINIMUM OF 1 1/2" x 8 1/2" OR 1 3/4" x 6 1/2" RESPECTIVELY. 5.FONT: 3/8" HEADER, 3/16" DATA 6.WHITE LETTERS ON A RED BACKGROUND. RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS WARNING DUAL POWER SOURCES RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS 1.(#1) PLACARD PLACED AT MAIN UTILITY SERVICE DISCONNECT/BREAKER AND PV SYSTEMSUPPLY BREAKER AT POINT OF INTERCONNECTION. (#2 & #3) PLACARD(S)REQUIRED WITH #1 PLACARD WHEN UTILITY SERVICE AND PV SYSTEM DISCONNECT(S) ARENOT LOCATED NEXT TO EACH OTHER. MAP PLACARD REQUIRED AS SPECIFIED. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. 2.1.VALUES WILL MATCH LOAD CENTER OR SUB-PANEL VALUES IF INSTALLED AFTER INVERTERS. IF AC CONNECTION TO SERVICE PANEL COMES FROM INVERTERS; SEESHEET "E-001 / STRING INVERTER[#] SPECIFICATIONS".2.1.1.INVERTERS ARE PARALLEL CONNECTIONS.2.1.2."RATED AC OUTPUT CURRENT" WILL BE THE SUM OF THE INVERTERS 2.1.3."AC NORMAL OPERATING VOLTAGE" WILL BE THE NAME PLATE RATING OF THEINVERTER 3.CODE REFERENCE: NEC 690.54, NEC 705.12(B)(3) 4.MINIMUM OF 2" x 6 1/2" (#1), VARIES (#2 & #3) 5.FONT: 3/8" HEADER, 3/16" DATA (#1), 1/4" (#2 & #3) 6.WHITE LETTERS ON A RED BACKGROUND. SCALE:1/2" = 1'-0"5 CAUTION WARNING ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION MAP PLACARD: MAIN SERVICE PANEL AND PV INVERTER (IF NOT SAME LOCATION)SCALE:1/2" = 1'-0" CAUTION 1.PLACARD PLACED AT ELECTRICAL SERVICE AND ATTHE PV INVERTER AND PV DISCONNECTS IF NOT AT THE SAME LOCATION. 2.MAP PLACARD PROVIDES A DIRECTORY OF THESERVICE DISCONNECTING MEANS ANDPHOTOVOLTAIC SYSTEM DISCONNECTION MEANS. 3.CODE REFERENCE: NEC 690.56(A)(B), 705.10 4.WHITE LETTERS ON A RED BACKGROUND. 5.MINIMUM OF 6 1/2" x 6 1/2" 6.FONT: 3/4" "CAUTION", 1/4" HEADER, 1/8" DATAAND NOTES 7.PLACARD WILL BE PLACED ADJACENT TO THE MAINSERVICE DISCONNECT IN A LOCATION CLEARLYVISIBLE FROM WHERE THE DISCONNECT ISOPERATED. (IFC 605.11.1.3) DC DISCONNECTS & DISCO. COMBINER (WITH COMBINED WARNING PLACARD IF REQUIRED. EXAMPLE: LADWP) PV SYSTEM DC DISCONNECT PHOTOVOLTAIC SYSTEM DC DISCONNECT PV SYSTEM DC DISCONNECT PHOTOVOLTAIC SYSTEM DC DISCONNECT #1 #2 #3 RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING STRING INVERTER #1 - INTEGRATED AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS STRING INVERTER #2 - INTEGRATED AC DISCONNECT AC DISCONNECT #1 - INDEPENDENT/ SEPARATE AC SUB-PANEL #1 #1 #2 #3 CODE ABBREVIATIONS:NATIONAL ELECTRICAL CODE (NEC)INTERNATIONAL BUILDING CODE (IBC)INTERNATIONAL RESIDENTIAL CODE (IRC)INTERNATIONAL FIRE CODE (IFC)UNDERWRITERS LABORATORY (UL)VDC MAXIMUM CIRCUIT CURRENT MAXIMUM VOLTAGE ADC MAX. CIRCUIT CURRENT MAXIMUM VOLTAGE ADC VDCVDC MAXIMUM CIRCUIT CURRENT MAXIMUM VOLTAGE ADC MAX. CIRCUIT CURRENT MAXIMUM VOLTAGE ADC VDCVDC NUTILITY METER &SERVICE PANEL AUTOTRANSFERSWITCH PRODUCTIONMETER AC DISCO RAPIDSHUTDOWNSWITCHEMERGENCYBATTERYDISCONNECT INVERTERW/ DC DISCO BATTERY SOLARARRAYON ROOFTOP UTILITY METER &SERVICE PANEL AUTOTRANSFERSWITCH PRODUCTIONMETER AC DISCO RAPIDSHUTDOWNSWITCH EMERGENCYBATTERYDISCONNECT INVERTERW/ DC DISCO BATTERY SOLAR ARRAYON ROOF TOP N32.0240240 32.081.2 81.2 240323323 32.0 240 32.0 32.0 240 P-002Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884415.050Landers, Jo6 Service Center Rd #2Northampton, MA 0106006/09/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANS7.6kW 1Ø PWRcell Inverter with CTsModel #: XVT076A03 11.4 kW 3Ø PWRcell Inverter with CTs Model #: X11402 (Ordering SKU: APKE00013) Solar + storage is simple with the Generac PWRcell™ Inverter. This bi-directional, REbus™-powered inverter oers a simple, ecient design for integrating smart batteries with solar. Ideal for self-supply, backup power, zero-export and energy cost management, the PWRcell Inverter is the industry’s most feature-rich line of inverters, available in single-phase and three-phase models. FEATURES & BENEFITS • Single inverter for grid-tied solar with smart battery integration • Simplified system design: No autotransformer or battery inverter needed • User-selectable modes for backup power, self-supply, time-of-use, zero-import and export limiting • Free system monitoring included via PWRview™ Web Portal and Mobile App AC OUTPUT/GRID-TIE MODEL XVT076A03 MODEL X11402 CONT. GRIDTIED AC POWER @ 50°C 122°F:7600 W 11400 W AC OUTPUT VOLTAGE:120/240, 1Ø VAC 120/208, 3Ø VAC AC FREQUENCY:60 Hz MAXIMUM CONTINUOUS OUTPUT CURRENT:32 A, RMS GROUNDFAULT ISOLATION DETECTION:Included CHARGE BATTERY FROM AC:Yes THD CURRENT:< 2% TYPICAL NIGHTTIME POWER CONSUMPTION1:< 7 W AC OUTPUT/ISLAND MODE MODEL XVT076A03 MODEL X11402 MAX. CONT. AC POWER WHILE IN ISLAND MODE WITHOUT AN EXTERNAL TRANSFER SWITCH2:7600 W MAX. CONT. AC POWER WHILE IN ISLAND MODE W/ EXTERNALTRANSFER SWITCH AND SINGLE 6 MODULE BATTERY CABINET3:9000 W MAX. CONT. AC POWER WHILE IN ISLAND MODE W/ EXTERNAL TRANSFER SWITCH AND 2 BATTERY CABINETS 8 MODULES MINIMUM3:11000 W 9600 W-11000 W* PEAK MOTOR STARTING CURRENT 2 SEC:50 A, RMS AC BACKUP OUTPUT VOLTAGE:120/240, 1Ø VAC 120/208, 1Ø VAC AC FREQUENCY:60 Hz THD VOLTAGE:< 2% ALLOWABLE SPLIT PHASE IMBALANCE:Up to 30% DC INPUT MODEL XVT076A03 MODEL X11402 DC INPUT VOLTAGE RANGE:360-420 VDC NOMINAL DC BUS VOLTAGE:380 VDC DC DISTRIBUTION INPUT BREAKERS:4 x 2P30 A MAX INPUT CURRENT PER DC INPUT:30 A REVERSEPOLARITY PROTECTION:Yes TRANSFORMERLESS, UNGROUNDED:Yes DC BUS EXPORT FUSES +/:40 A 2POLE DISCONNECTION:Yes EFFICIENCY MODEL XVT076A03 MODEL X11402 PEAK EFFICIENCY:97.3%97.7% CEC WEIGHTED EFFICIENCY:96.5%97.5% 1Nighttime power consumption depends on the system mode2In Island Mode, continuous power output is restricted to 7.6kW unless backup power is routed through an external transfer switch in a whole home backup application. 3Peak performance, values provided for 40°C (104°F).*In Island mode X11402 protected loads only supply 2 phases 120 VAC L-N, 208 L-L which results in lower power than in a grid tied 3 phase state. The low value of the range is for full L-L loading while high value of the range is full L-N loading Specifications Generac Power Systems, Inc. S45 W29290 Hwy. 59, Waukesha, WI 53189 www.Generac.com | 888-GENERAC (436-3722) A0000909057 REV D ©2021 Generac Power Systems. All rights reserved. Specifications are subject to change without notice. FEATURES AND MODES ISLAND MODE4:Yes GRID SELL:Yes SELF CONSUMPTION:Yes PRIORITIZED CHARGING FROM RENEWABLES:Yes GRID SUPPORT ZERO EXPORT:Yes ESS PCS OPERATION MODES IMPORT ONLY, EXPORT ONLY:Yes ADDITIONAL FEATURES SUPPORTED COMMUNICATION INTERFACES:REbus™, CANbus, Ethernet SYSTEM MONITORING:PWRview™ Web Portal and Mobile App BACKUP LOADS DISCONNECT4:Yes, 50 A Circuit Breaker INVERTER BYPASS SWITCH:Automatic WARRANTY:10 Years DIMENSIONS AND INSTALLATION SPECIFICATIONS ENCLOSURE KNOCKOUTS QTY, SIZE IN MM:6 x Combo 3/4" x 1" (19 x 25.4) 7 x Combo 1/2" x 3/4" (12.7 x 19) DIMENSIONS L x W x H IN MM:24.5" x 19.25" x 8" (622.3 x 488.9 x 203.2) WEIGHT LB KG:62.7 (28.4) COOLING:Forced convection AUDIBLE NOISE:< 40 dBA OPERATING TEMPERATURE:-4 to 122 °F (-20 to 50 °C)5 ENCLOSURE TYPE:Type 3R STANDARDS COMPLIANCE SAFETY:UL 1741 SA, CSA 22.2 #107.1, UL 1998 GRID CONNECTION STANDARDS:IEEE 1547, Rule 21, Rule 14H (HECO V1.1), CSIP, UL 1741 PCS CRD (Import Only, Export Only) EMISSIONS:FCC Part 15 Class B INSTALLATION GUIDELINES BATTERY TYPES SUPPORTED:PWRcell™ Battery MODULE SUBSTRING SIZE PER PV LINK OPTIMIZER:Varies, refer to PV Link Installation Manual MAXIMUM RECOMMENDED DC POWER FROM PV6:10 kW (1Ø), 15 kW (3Ø) 1 x 0.575" exclusively for optional LTE antenna mounting 43Ø inverters oer backup for [single phase] 208 V loads.5Includes ambient temperature rising from inverter operation. Reduced power at extreme temperatures. 6Values provided for PV-only or small storage systems. Additional PV power is permissible if sucient battery storage capacity is installed. INVERTER CUT SHEET R-101Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884415.050Landers, Jo6 Service Center Rd #2Northampton, MA 0106006/09/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSDC/DC CONVERTERS CUT SHEET R-102Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884415.050Landers, Jo6 Service Center Rd #2Northampton, MA 0106006/09/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSModel APKE00007, PWRcell Battery CabinetModel A0000391219, 2.85kWh PWRcell Battery ModuleCertification Model Reference: BJ-DCB05ZKAXModel APKE00008, PWRcell Spacer KitModel APKE00009, PWRcell Upgrade KitCertification Model Reference for Battery Configurations: PWRcell 9, PWRcell 12, PWRcell 15, PWRcell 17 The PWRcell™ Battery Cabinet is a modular smart battery platform that allows for a range of configurations to suit any need, small or large. No other smart battery oers the power and flexibility of PWRcell. Whether for backup power or smart energy management, PWRcell has power and capacity options for every need, without sacrificing flexibility or function. Specifications FEATURES & BENEFITS • Connect 2 PWRcell Battery Cabinets to a single PWRcell Inverter for up to 36kWh of storage • Best-in-class battery backup power • Plug-and-play with PWRcell Inverter and PV Link™ • Time-of-use (TOU) and zero-export ready • Residential and commercial application ready. BATTERY CONFIGURATION GUIDE BATTERY CABINET ASSEMBLY PWRcellBattery Cabinet M6 6x Battery Module M5 5x Battery Module+ Module Spacer Kit M4 4x Battery Module M3 3x Battery Module+ Module Spacer Kit OR OR OR SPACER SPACER PWRcellBattery CabinetBack PanelModuleSpacer Kitx1 BatteryModulex5PWRcellBattery CabinetFront Panel PWRcell BATTERY CABINET DESIGN The PWRcell Battery Cabinet allows system owners the flexibility to scale from an economical 9kWh to a massive 18kWh by installing additional battery modules to the PWRcell Battery Cabinet. When needs change, an existing PWRcell Battery Cabinet can be upgraded with additional modules. Use the graphic below and the chart on the back of this sheet to understand what components you need for your chosen PWRcell configuration. PWRcell™ BATTERY CONFIGURATIONS BATTERY MODULE SERIES:3.0 kWh DCB BATTERY MODULES:3 4 5 6 USABLE ENERGY:9 kWh 12 kWh 15 kWh 18 kWh NOMINAL CONT. AC POWER1 3.4 kW 4.5 kW 5.6 kW 6.7 kW MAX. CONT. AC POWER2 4.5 kW 6 kW 7.5 kW 9 kW PEAK MOTOR STARTING CURRENT 2 SEC - A, RMS 25 33 42 50 REbus™ VOLTAGE - INPUT/OUTPUT:360-420 VDC NOMINAL VOLTAGE:46.8 VDC DC-DC ROUND-TRIP EFFICIENCY:96.5% MAXIMUM AMBIENT OPERATING TEMPERATURE:14 to 122 °F -10 to 50 °C RECOMMENDED AMBIENT OPERATING TEMPERATURE:41 to 104 °F (5 to 40 °C) MAXIMUM INSTALLATION ALTITUDE - FT M:98343000 DIMENSIONS, L x W x H - IN MM:22” X 10” X 68”559 X 254 X 1727 WEIGHT, ENCLOSURE - LB KG:111 50 WEIGHT, INSTALLED - LB KG:276 (125)331 (150)386 (175)441 (200) ENCLOSURE TYPE:Type 1 WARRANTY - LI-ION MODULES:10 Years, 7.56MWh WARRANTY - ELECTRONICS AND ENCLOSURE:10 Years COMMUNICATION PROTOCOL:REbus™ DC Nanogrid™ COMPLIANCE:UL 9540, UL 1973, UL 1642, CSA 22.2 #107.1 Generac Power Systems, Inc. S45 W29290 Hwy. 59, Waukesha, WI 53189 www.Generac.com | 888-GENERAC (436-3722) A0000528139 REV G ©2020 Generac Power Systems. All rights reserved. Specifications are subject to change without notice. PWRcell ACCESSORIES The PWRcell Indoor Rated Battery Cabinet (APKE00007) is rated for indoor use only. If installing outdoors, the PWRcell Outdoor Rated Battery Cabinet (APKE00028) must be used. Inside of the PWRcell Battery Cabinet, battery modules are stacked two deep on three levels, allowing for up to six modules to be connected in series. You can upgrade an existing PWRcell Battery Cabinet by adding Battery Modules and a Module Spacer (APKE00008). A Module Spacer is only required for battery configurations with an odd number of modules (i.e. 3 or 5). Generac oers a convenient PWRcell Battery Upgrade Kit (APKE00009) to help replace lost or misplaced hardware. PWRcell MODEL BUILDER PRODUCT SERIES ENCLOSURE TYPE # OF MODULES BATTERY SERIES PWRcell IR IR (Indoor Rated) OR (Outdoor Rated) M3 3 Modules 4 Modules 5 Modules 6 Modules DCB DCB Sample Model Name: PWRcell IR M3 DCB 1Average AC power over a complete discharge cycle. 2Peak Performance, values provided for 40*C (104*F).Note: Charge/discharge rate may be reduced at temperature extremes BATTERY CUT SHEET R-102Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884415.050Landers, Jo6 Service Center Rd #2Northampton, MA 0106006/09/2021SUBMIT FOR PERMIT | 740-249-1877 | www.ecolibriumsolar.com Three main components PVinstallationProfessionalsuseEcoFoot2+tocompletetheirprojectsin recordtime.TherefreshedEcoFoot2+designisnowavailableinBlack, alongwithacomprehensiveUL2703certification. Base OurnewUL-ListedASAbased resinisadurablematerialcommonly usedinautomotiveandconstruction applications.Thematerialis classAfireratedaspartof ourUL2703Certification. PreassembledUniversalClamp Thenewpreassembleduniversal clampachievesintegratedgrounding withouttheuseofgroundingwashers. TM Back in Black PV installation Professionals use EcoFoot2+ to complete their projects in record time. The refreshed EcoFoot2+ design is now available in Black, along with a comprehensive UL2703 certification. WindDeflector Corrosion-resistantwind deflectoroneverymodulehelps minimizeuplift,reduceballast requirementsandcarriesUL2703 validatedgroundpathfrom modulesandrackingcomponents. 1ooo System Benefits Lowpartcount Rapidsystemdeployment PreassembledUniversalClamp Increaseddesignflexibility Moreballastcapacity Simplifiedlogistics (upto50kWperpallet) Validation Summary CertifiedtoUL2703FireClassA forTypeIandIImodules CertifiedtoUL2703 GroundingandBonding Windtunneltestedto150mph SEAOCseismiccompliant CFDandstructurallytestedDNVGL ratedat13.5panelsperinstaller-hour — — — — — — — — — — — Technical Specification s Dimensions:26.5”Lx18.25”Wx8.3”H TypicalSystemWeight:3.5–6lbs.persq.ft. Moduleorientation:Landscape/Portrait Tiltangle:Landscape10°/Portrait5° Moduleinter-rowspacing:18.9” Roofpitch:0°to7° Ballastrequirements:4”x8”x16” Warranty:25years EcoFoot2 + Installer Feedback = EcoFoot2+™ Our design enhancement s help you master the most challenging site an d rooftop conditions 1oooRELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSSTANCHION - ROOF ATTACHMENT CUT SHEET R-103Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884415.050Landers, Jo6 Service Center Rd #2Northampton, MA 0106006/09/2021SUBMIT FOR PERMIT Business Stream Products Renewable and Solar Technology TÜV Rheinland PTL Photovoltaic Testing Laboratory 2210 South Roosevelt Street Tempe, Arizona 85282 Main Phone: 480-966-1700 Main Fax; 775-314-6458 Email: info@tuvptl.com TÜV Rheinland North America Holding, Inc. 1 Federal Street Boston, MA 02110 Main Phone: 617-426-4888 Main Fax: 617-426-6888 Member of TÜV Rheinland Group Attn: Mr. Chad Parsons Ecolibrium Solar 340 West State Street Athens, OH 45701 USA Email: jcastagna@us.tuv .com 480-966-1700, x153 June 16, 2014 UL SU 2703 Bonding Tests Completed Type of Equipment: PV Mounting System Model Designation: Ecolibrium Solar Ecofoot2+ Test Requirement: UL Subject 2703 TÜV Rheinland File Number: L1-ELS130905 TÜV Rheinland Project Number: ELS130905 Dear Mr. Parsons, This letter is confirmation that the Ecolibrium Solar Ecofoot2+ PV Mounting System has successfully completed electrical bonding tests according to the UL Subject 2703 standard. Congratulations on this achievement. All summary test results will be provided to you separately when the full report is completed. The final Test Report and associated Constructional Data Form (CDF) will be submitted to our certification department for final processing and subsequent listing on the TUV Rheinland Certipedia website. You may use this correspondence as an interim Letter of Compliance (LOC) indicating your system has met the relevant bonding requirements of UL Subject 2703. Sincerely, Jack Castagna Solar Components Program Manager TÜV Rheinland PTL, LLC RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSSTANCHION - ROOF ATTACHMENT CUT SHEET R-104Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884415.050Landers, Jo6 Service Center Rd #2Northampton, MA 0106006/09/2021SUBMIT FOR PERMIT KN FRIRR3OVB,VDOOBLGB9,1/-o -DDU6FROLEULPVRODUFRP hhD / t d FRIRR3OVB,VDOOBLGB9,1/-o -DDU6FROLEULPVRODUFRP uom7bmom7bm ddsh t/ EE/EW tt K t tht K ,:,: t EhD& hEh E ERELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSSTANCHION - ROOF ATTACHMENT CUT SHEET R-105Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884415.050Landers, Jo6 Service Center Rd #2Northampton, MA 0106006/09/2021SUBMIT FOR PERMIT pe.eaton.com General Duty Non-Fusible Safety Switch DG222URB UPC:782113144238 Dimensions: Height: 7.5 IN Length: 6.41 IN Width: 8.4 IN Weight:9 LB Notes:WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Warranties: Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: Type: General Duty/Non-Fusible Amperage Rating: 60A Enclosure: NEMA 3R Enclosure Material: Painted galvanized steel Fuse Configuration: Non-fusible Number Of Poles: Two-pole Number Of Wires: Two-wire Product Category: General Duty Safety Switch Voltage Rating: 240V Supporting documents: Eatons Volume 2-Commercial Distribution Eaton Specification Sheet - DG222URB Certifications: UL Listed Product compliance: No Data______________________________________________________________________ © 2016 Eaton. All rights reserved. V2-T1-26 Volume 2—Commercial Distribution CA08100003E—May 2018 www.eaton.com 1 1.1 Switching Devices Safety Switches All general-duty switches above 100A and all heavy-duty switches incorporate these K-Series switch design features. Two points of contact provide a positive open and close, easier operation, and also help prevent contact burning for longer contact life Visible Double-Break Rotary Blade Mechanism Protects against accidental contact with energized parts. Probe holes enable the user to test if the line side is energized without removing the shield. Not provided on general-duty switches, but available as a field kit or factory installed Clear Line Shield Clearly Visible Handle ●The position (ON or OFF) can be clearly seen from a distance and the length provides for easy operation Triple Padlocking Capability ●Personnel safety feature because the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks Additional Locking Capability ●Cabinet door can be further padlocked at the top and bottom as applicable Interlocking Mechanism ●Door cannot be opened when the handle is in the ON position. Front and side operable defeater mechanism provides for user access when necessary on single- throw switches Tangential Knockouts ●An ample number are provided on the top, bottom and sides of both NEMA Types 1 and 3R enclosures through 200A Bolt-On Hub Kits ●For switches in a NEMA Type 3R, 30–200A. Use a Myers type hub for all others Standards and Certifications ●UL listed File No. E5239 ●Meets UL 98 for enclosed switches and NEMA Std. KS-1 Seismic Qualifications ●General-duty switches exceed the requirements of Uniform Building Code (UBC) and California Code Title 24 OSP-0011-10, OSP-0012-10 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSAC DISCONNECT CUT SHEET R-106Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884415.050Landers, Jo6 Service Center Rd #2Northampton, MA 0106006/09/2021SUBMIT FOR PERMIT