Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
36-265 (3)
211 MAPLE RIDGE RD BP-2021-1568 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 36-265 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2021-1568 Project# J S-2021-002597 Est.Cost: $27694.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: PIONEER VALLEY PHOTOVOLTAICS 111266 Lot Size(sq.ft.): 151588.80 Owner: FIENGOLD BARRY&MARCIE S YOSS Zoning: Applicant: PIONEER VALLEY PHOTOVOLTAICS AT: 211 MAPLE RIDGE RD Applicant Address: Phone: Insurance: 311 WELLS ST - SUITE B (413) 772-8788 Workers Compensation GREENFIELDMA01301 ISSUED ON:6/30/2021 0:00:00 TO PERFORM THE FOLLOWING WORK:INSTALL 20 MODULE 7.5 KW SOLAR SYSTEM ON ROOF WITH 2 INVERTERS IN BASEMENT (1 REPLACING A SE6000A-US INVERTER) POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. 10 3)9, Certificate of Occupancy Signaturi FeeType: Date Paid: Amount: Building 6/30/20210:00:00 $75.00 212 Main Street, Phone(413)587-1240, Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner Department use only �J P HAMpt�, �c City of Northampton Status of Permit: 0 0� Building Department Curb Cut/Driveway Permit tc,"'� 212 Main Street Sewer/Septic Availability 40, = Room 100 Water/WellAvailability , Northampton, MA 01060 Two Sets of Structural Plans -d' Thone 413-587-1240 Fax 413-587-1272 Plot/Site Plans z Other Specify ,03.ICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office Map 33(v Lot 245— Unit 211 Maple Ridge Rd, Florence MA 01062 Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: FEINGOLD, BARRY&MARCIE S YOSS 211 MAPLE RIDGE RD, FLORENCE MA 01062 Name(Print) Current Mailing Address: 413-586-7343 See Attachment A Telephone Signature 2.2 Authorized Agent: Pioneer Valley Photovoltaics 311 Wells St. Greenfield,MA 01301 Name(Print) / Current Mailing Address: A 413-772-8788 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building (a)Building Permit Fee 2. Electrical (b)Estimated Total Cost of Construction from(6) 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 6. Total=(1 +2+3+4+5) $27,694 Check Number This Section For Official Use Only Building Permit Number: 8 P-Zo 21/6 i1 Date Issued: Signature: � 6- 3o -Z_0Z Building Commissioner/Inspector of Buildings Date buildingpermits @ pvsquared.coop EMAIL ADDRESS (REQUIRED; EITHER HOMEOWNER OR CONTRACTOR) Section 4. ZONING All Information Must Be Completed.Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage Open Space Footage (Lot area minus bldg&paved parking) #of Parking Spaces Fill: (volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO 0 DONT KNOW O YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DONT KNOW O YES 0 IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO O DON'T KNOW O YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained O Obtained O , Date Issued: C. Do any signs exist on the property? YES 0 NO O IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES O NO O IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO ® IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors El Accessory Bldg. El Demolition ❑ New Signs [D] Decks [E Siding[D] Other[mj Brief Description of Proposed Installation of a 7.5 kW-DC PV system;(20)panels on SW house roof Work: Alteration of existing bedroom Yes " No Adding new bedroom Yes "" No Attached Narrative Renovating unfinished basement Yes ra No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building :One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT MARCIE YOSS & BARRY FEINGOLD as Owner of the subject property PV Squared (Pioneer Valley Photovoltaics) hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. See Attachment A See Attachment A Signature of Owner Date PV Squared ,as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Daniel Gomez Print Name AX 6/23/2021 Signature of Owner/Agent Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: Daniel Gomez Gonzalez License Number 43 Hatfield St. Northampton, MA 01060 CS-111266 Address Expiration Date 03/14/2023 Signature //n�' / Telephone 413-772-8788 9. Registered Home Improvement Contractor. Not Applicable ❑ Pioneer Valley Photovoltaics Cooperative Company Name Registration Number 311 Wells Street, Suite B, Greenfield, MA, 01301 140077 Address Expiration Date 413-772-8788 Telephone 09/15/2021 SECTION 10-WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes u No ❑ Attachment A Note. Owner-Caord.rtated beaming can include a ux, man program offered by their local bank(e g,MA rive College Federal Credo Union's Kt Solar(don) to this cal.. the First Payment shown above Witt accompany the sighed Authprtration and the project piyrrrent schedule will")t:,l.r+w the barrk's solar tc+an program guidelines for the net coat. When You Mr*in Prnpncal.It becomes the 'Proposal and Agret=ment'for the Protect,subject to the attached Terms and Condemns Please retain a copy for your records and return a s/gned copy to PV Squared Receipt by PV Squared of a scald copy of the Proposal and Agreement abt+l;with the Fast Payment stated above will serve as authorization for PV Squared to proceed with the above described:'rr>)ert You reserve the nghi to cancel this contrail within text•,•business oays of signing the Authorization to P'pceed Contract IPrmination can be executed using the enclosed Righ' of Rescission form PV Squared n committed to amending a trglt quality product and service,tend we Iota forward to worlrng with you on your renewable energy moped. S+ncerety, .ocw e+Valley PhatoVoltacs Cooperative Karen Pitxar,, Design and Sates Tearr Attachments A-PV Array Sketch Genera Terms and(nnitit,an; Right of Rescrssior. AUTHORIZATION TO PROCEED AND SERVE AS AUTHORIZED AGENT hereby agree to the Projnet as set out above,and I agree to pay Dr, contract pore a t cording to the Terms of Payment further agree to the Terms and Conditions attached hiKeto as a part of this Proposal and ASpeentent thereby authorize Pioneer Valley PhotoVriftares Cnociefatrwe proceed with the abo+r«•refere ced Project in accordance with this Agreement.I further author ze Pioneer Valley Photovoltares Cooperative.or its designated representative, to obtain required permits for this project on behalf al the Owner,I will allow any photographs or videos of this project to tie used by Pioneer Valley Phot,Voltarcs Cooperative for marketing purposes.A check for the First Payment is enclosed and l am returrang this Agreement within 71 days of twxa Proposal date. Pnnted Name Date s�qr+-tor Tipp nem*woo narc.Jnrw a attotstlrt ern Clot U airy+i+tpw }Miry Is ItUI A. �'" Commonwealth of Massachusetts z Dtvtsion of Professional Licensure Board of Building Regulations and Standards Constructth,� up rvisor CS-111266ii i cpires: 03/14/2023 DANIEL GOMEZ-GONZALEZ 43 HATFIELD STREET ' NORTHAMPTON MA 01060 f =-- c 4 imo Commissioner d, ,t. K. Yektnlik, i . .&,/ /f//iIUV ,f/W/// / „.,// r.-i.)/1'r,44e///i Office of Consumer Affairs and Business Regulation 1000 Washington Street - Suite 710 Boston, Massachusetts 02118 Home Improvement Contractor Registration Type: Supplement Card PIONEER VALLEY PHOTOVOLTAICS COOP Registration: 140077 311 WELLS ST SUITE B Ex piration: 09/15/2021 GREENFIELD, MA 01301 SCa I 0 20t.1 os f Update Address and Return Card. Office of Consumer Affairs 8 Business Regulation HOME IMPROVEMENT CONTRACTOR Registration valid for individual use only TYPE: Suoolement Card before the expiration date. If found return to. Registration expiration Office of Consumer Affairs and Business Regulation 140077 09/1512021 1000 Washington Street ,Suite 710 '/ PIONEER VALLEY PHOTOVOLTAICS COOP Boston,MA 02118 / I I MAYA FULFORD G � 311 WELLS ST SUITE B .ib n-.ef,e .':c64rek 7 I A-...---,_ / 'J GREENFIELD,MA 01301 , of valid ithout signat Ire Undersecretary AC Ro® CERTIFICATE OF LIABILITY INSURANCE DATE ti2v2o2om THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Kathy Parker NAME: Webber&Grinnell (NCN o.Exq: (413)586-0111 wc,No): (413)586-6481 8 North King Street E-MAIL kparker@webberandgrinnell.com ADDRESS: / INSURER(S)AFFORDING COVERAGE NAIC 0 Northampton MA 01060 INSURER A: Ohio Casualty/Liberty 24074 INSURED INSURER B: Ohio Security/Liberty 24082 Pioneer Valley PhotoVoltaics Cooperative,Inc. INSURER C: Continental Indemnity/AUW Attn:Kim Pinkham INSURER D 311 Wells Street,Suite B INSURER E: Greenfield MA 01301 INSURER F: COVERAGES CERTIFICATE NUMBER: CL20122214681 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER (MMIDD/YYYY) (MMIDD/YYYY) LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1.000.000 CLAIMS-MADE XI OCCUR DAMAGE TO RENTED 300,000 PREMISES(Ea occurrence) $ MED EXP(Any one person) $ 15,000 A BKS57072282 01/01/2021 01/01/2022 PERSONAL aADVINJURY $ 1.000.000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY PERCOT- LOC PRODUCTS-COMP/OP AGG $ 2.000•C" OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1.000,000 (Ea accident) ANY AUTO BODILY INJURY(Per person) $ B OWNED >/ SCHEDULED BAS57072282 01/01/2021 01/01/2022 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS X HIRED v NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY (Per accident) Underinsured motorist $ 300,000 .,.,... .... UR E 000 ..... 5,000.X UMBRELLA LIAB _^ OCCUR EACH OCCURRENCE $ A EXCESS LIAB CLAIMS-MADE US057072282 01/01/2021 01/01/2022 AGGREGATE $ 5,000.000 DED X RETENTION$ 10,000 $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY STATUTE ER Y C ANY PROPRIETOR/PARTNER/EXECUTIVE � N/A 375928710101 01/01/2021 01/01/2022 E.L.EACH ACCIDENT $ 1•DL)0•<100 OFFICER/MEMBER EXCLUDED? (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 1.000,000 If yes,describe under 1 AU0,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ Business Pers Property $1,820,700 A Commercial Property BKS57072282 01/01/2021 01/01/2022 Installation $25,000 Transportation $75,000 DESCRIPTION OF OPERATIONS!LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) Worker's compensation includes MA and NY CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Proof of Insurance ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE 11L e�-4 ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts _"'y, _Al, Department of Industrial Accidents ?el_ I Congress Street,Suite 100 ==tt_ Boston,MA 02114-2017 704 www mass.gov/dia Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name (Business/Organization/Individual):Pioneer Valley PhotoVoltaics Cooperative Inc. DBA PV Squared Solar Address:311 Wells Street, SuiteB City/State/Zip:Greenfield MA 01301 Phone#:413-772-8788 Are you an employer?Cheek the appropriate box: Type of project(required): 1.0 I am a employer with 48 employees(full and/or part-time).* 7. ❑New construction 2.0 I am a sole proprietor or partnership and have no employees working for me in 8. EI Remodeling any capacity.[No workers'comp.insurance required.] 3.0 I am a homeowner doing all work myself.[No workers'comp.insurance required.]t 9. ❑Demolition 4.0 I am a homeowner and will be hiring contractors to conduct all work on my property. I will 10 Building addition ensure that all contractors either have workers'compensation insurance or are sole 11.0 Electrical repairs or additions proprietors with no employees. 12.0 Plumbing repairs or additions 5.1=1 I am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13.DROOf repairs These sub-contractors have employees and have workers'comp.insurance.: 6.0 We are a corporation and its officers have exercised their right of exemption per MGL c. 14.❑✓ Other 152,§I(4),and we have no employees.[No workers'comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:Continental Indemnity/AUW Policy#or Self-ins.Lic.#:37-592871-01-01 Expiration Date:01/01/2022 Job Site Address:211 MAPLE RIDGE RD City/State/Zip: FLORENCE MA 01062 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby ce :r.t e :l,' �d penalties of perjury that the information provided above is true and correct Signatu- . i� &Oil Date: 6/23/2021 Phone :413-7 -87 8 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: l FEINGOLD RESIDENCE N SITE MAP St.fluk• 211 MAPLE RIDGE RD 9.4 »�- �«-M�� FLORENCE MA 01062 r f '�# :t ' SC)Pgm i+ -i} s ayr�, N LAR PHONE:(413) 586-7343 f' r ,4 . ` j' 2 '»0 � E—MAIL:BSFEINGOLDCGMAIL.COM d ' J� '` 0• . r ` a"ir r l' Z CD ROOF MOUNTED PHOTOVOLTAIC SYSTEM EXPANSION '�,,g;4 `44;. Wit' Q t' •• .•. .,'.-e •V Es w EE Z i rd !,i _ s N _ Lt PHOTOVOLTAIC SYSTEM DETAILS s' > < w • MODULES =REC REC375AA 375W (20 PCS) ,• Try 'q �2 a s1'' • O 0_ Z 4 • INVERTER = SOLAREDGE SE5000H-US (1 PCS) , •: " ;"' , {* Iitir f O Z O g • RACKING SYSTEM = IRONRIDGE XRI00 W/ QUICKFOOTy � � LTJz — —I•DATA ACQUISITION =SOLAREDGE CONSUMPTION MONITORING U_ N LL AUTHORITY HAVING JURISDICTION N •BUILDING AUTHORITY = CITY OF NORTHAMPTON ® VICINITY M A P • CODE REFERENCE = 2020 NEC • ELECTRICAL UTILITY COMPANY =NGRID DESIGN CRITERIA w • DESIGN WIND LOAD = 117 MPH 1> •DESIGN ROOF SNOW LOAD =40 PSF t •EXPOSURE CATEGORY= C •HIGH TEMP (ASHRAE 2%HIGH) =32°C g p.p (� Ca i p E •LOW TEMP (ASHRAE EXTREME LOW) = -20°C F,- •ROOF TYPE = ASPHALT SHINGLE W g i� ago u SHEET INDEX .; .te PV-G.0 COVER PAGE PV-A.I ARRAY LAYOUT 0 PV-E.I LINE DIAGRAM PV E.2 ELECTRICAL CALCS 2 Ch W CDPV-P.I PLACARDS t LJ LIJQ o U i a_ ROOF CONSTRUCTION MODULE CLAMP ZONESto, 0 • ROOF TYPE = ASPHALT SHINGLE MODULE MODEL: REC375AA DESIGN INPUTS-SATELLITE IMAGERY 8 FIELD MEASUREMENTS • PV ARRAY = 376 SQUARE FEET MODULE DIMENSIONS: 67.75'X 40.00" ,, ,,,, „+,a•„r,°,,� • TYPICAL ATTCHMENT SPAN =48' CLAMP BETWEEN: "'P"ec`""'""'" • MAX ATTACHMENT SPAN =68' 8.2"- 23.8'ON THE LONG SIDE• MAX CANTILEVER = 27.2' 4"-9.8'ON THE SHORT SIDE a O WWI" • ATTACHMENTS SHALL BE STAGGERED el 8 ,o,.....,....,...‘.MP SO THE LOAD IS DISTRIBUTED EVENLY ' �4 TO TRUSSES UNDERNEATH THE ARRAY ap L� LLI N Z /X o UJ W p in 1 z _ o TRUSSES, 24' O.C. RAIL ATTACHMENTS W N O i i EXISTING PV ARRAY CZ r o UTILTY METER-EXTERIOR ii t ����r SMART METER- EXTERIOR ;3 . ' rre PV AC DISCONNECT -EXTERIOR d "' d tlin 1 -'----- - I i 1 I MAIN SERVICE PANEL INTERIOR 1.« FUSED PV AC DISCONNECT INTERIOR a�& III *II, a_ z,,..3 H,ar i ar?i INVERTER - INTERIOR E,, g i z ARRAY INFORMATION STRING CONFIGURATION Q H STRING SIZE DOES NOT VARY ix 0 0 1 MOD QTY 20 STRINGS QTY Q o TILT 26° STRING I 10 4 _1Z AZIMUTH 235° STRING 2 10 New England Construction Engineering, PLC 436 Campbell Street (NECE) Structural Construction Solutions White River Junction, VT 05001 Jonathan Rugg, P.E. 603-903-9798 j.rugg@NewEnglandConstructionEngineering.com June 10, 2021 Mr. Bill Killough-Hill Pioneer Valley PhotoVoltaics Cooperative, Inc. 311 Wells Street, Suite B Greenfield, MA 01301 Re: Feingold Residence, Project#2, Florence, MA NECE Project No. 21-01 T55 Dear Mr. Killough-Hill, At your request, New England Construction Engineering, PLC (NECE) has reviewed the information that Pioneer Valley PhotoVoltaics Cooperative, Inc. (PV Squared) provided on the roof supporting structure of the Feingold residence, at 211 Maple Ridge, in Florence (Village of Northampton), MA.The purpose of this review was to provide an opinion regarding the structure's capacity to support a proposed rooftop mounted photovoltaic (PV) array.The information that you provided is attached to this letter for reference. You are proposing to mount PV panels on the front side house roof.There is already a PV array over the living space above the attached two-story garage.Your proposed array will be mounted on the main house.The main house measures approximately 32'x42'.The house has a gable roof,with a 30-degre pitch. The roof is symmetric about the peak. The roof is supported by manufactured wood roof trusses spaced 24" O.C. These trusses span 32' between exterior walls. The trusses have 2x4 top and bottom chords, and 2x4 webs.The center vertical web member has lateral bracing at its midpoint. The roof has a plywood deck and asphalt shingles. The photographs you provided suggest that the house is well maintained and that the roof is performing well. There is no evidence of distress or large deflections. NECE's review and analysis included the controlling gravity load combinations (snow and dead load). Consideration of snow load included both balanced and unbalanced (drifted) snow load design cases. Development of sloped roof snow loads (Ps) indicated that the increase in dead load from the PV array, is more than offset by the reduction of sloped roof snow load, owing to the smooth, snow shedding surface of the PV panels.This is the case despite the higher thermal coefficient (Ct) due to the thermal break under the array. New England Construction Engineering, PLC PV Squared—Feingold#2 Jonathan Rugg, P.E. Florence, MA Page 2 of 2 Conclusion: Based on the information that you provided, I conclude that, the roof will support your proposed PV array. I base this on the following. The proposed PV panels will be installed parallel to the existing roof, eliminating additional wind load. Based on the information that you have provided on similar projects; I assume that the PV panels weigh approximately 2.3 psf. The Ground Snow Load (Pg) for Northampton is 40psf. The minimum Flat Roof Snow Load (Pf) is 35psf. In summary, in my opinion,the roof will adequately support your proposed roof mounted PV array. Thank you for the opportunity to assist with this project. If NECE can be of further assistance, please contact Jonathan Rugg at NECE. Ai"' OF yAss40 Sincerely, JONATHAN A o RUGG >4/1/dt, lb„/PtC/STE0 `S/ONAI � ' .. Jonathan Rugg, P.E. I , w• New England Construction Engineering, PLC. 5/27021 Attachments: -Building Information c -ST TRUSTED REC ri ), ..„ „,, ‘ , ,, ,, . .. if ..t ( ''' kAs.3 Al 1 .11A) : tiy I ' ) . r / , • ' i �� --� A :r MIN MEM 6 MES ..1. 4 '„ , a a"°' .ps it- . MOM * 1 MI , Elli rl /8 't. isimil _.._..... um .4 — El - , REE ALPHOC nom _ ME .i. ti . SERIES lir _ , , , ._ _. ,, , ,_ . , ‘ 380 WP POWER l', 20 YEAR PRODUCT WARRANTY IOC '; 25 YEAR POWER OUTPUT WARRANTY recgroup.com/alpha t i REC ALAHOC SERIES PRODUCT DATA5HEET CERTIFICATIONS IEC 61215:2016,IEC 61730:2016,UL 1703,UL 61730 IEC 62804 PID _ 1 rn+7 S 167.7s to ll - 28[1.1] 902[315] + 455[ns] !EC61701 Salt Mist _ IEC 62716 Ammonia Resistance-� _ _+ UL 1703 -- Fire Type Class 2 l` moo� IEC 62782 Dynamic Mechanical Load IEC 61215-2:2016 Hailstone(35mm) AS40402NCC 2016 Cyclic Wind Load --� I50140012004,I509001:2015.OHSAS 18001:2007o B. s�• C E r - c us o WARRANTY 5 11to.2 20 year product warranty [0.43 t0.81 25 year linear power output warranty Maximum annual power degression of 0.25%p.a. A Guarantees 92%of power after 25 years '" 20530 See warranty conditions for further details. ci [0.78*QOM 1200[471 - r ,,,e - f A. - , MECHANICAL DATA A Dimensions: 67.8x 40x1.2 in(1721x1016 x 30 mm) 225[0.9] 621t1[245i0.04] -- -------------.__...-..-.-----. _..__.. 45[151 r Area: 18.8sgft(1.75m2) 1_ _.- J 30 I1.181 GENERAL DATA Measurements in mm linl ' Weight 43 lbs(19.5 kg) 120 half-cut cells with REC 3b ass diodes IP67rated Junction box: 3-part, yp , MAXIMUM RATINGS Cell type: heterojunction cell technology in accordance with IEC 62790 6 strings of 20 cells in series 12 AWG(4mm2)PV wire.39+47 in(1+12 m) Operational temperature: 40...+85°C Operational at-_ Cable: in accordance with EN50618 Maximum system voltage: 1000V 0.13 in(3.2 m m)solar glass with Glass: Design + snow 4666Pa anti-reflection surface treatment g ( ): (9751b5/sgft)' 5taubliMC4PVKBT4/K5T4,12AWG(4rm12) Maximum test load(+): 7000Pa(146lbs/sgft)* Highly resistant Connectors: in accordance with IEC 62852 Backsheet: polymeric construction IP68 only when connected Design load(-):wind 2666Pa(55.6lbs/sgft)' Maximum test load(-): 4000 Pa(83.51bs/sq ft)* • Frame: Anodized aluminum(black) Origin: Made in Singapore ft Max series fuse rating: 25A g. ELECTRICAL DATA @ STC Product Code':RECxxxAA Max reverse current: 25A r Nominal Power-P„pp(Wp) 360 365 370 375 380 'Cakulatedusingasafetyfactorofl.S 3 Watt Class Sorting-(W) -0/+5 , -0/+5 -0/+5 -0/+5 -0/+5 installation manual for mounting instructions ao NominalPower Voltage-V,q,(V) 37.7 38.0 38.3 38.7 39.0 TEMPERATURE RATINGS' o Nominal Power Current-1, (A) 9.55 9.60 9.66 9.72 9.76 Nominal Module Operating Temperature: 44°C(t2'C) d . Open Circuit Voltage-Voc(V) 44.1 443 44.5 44.6 44.7 Temperature coefficient of P,, -0.26%/°C g . p Short Circuit Current-Isc(A) 10.23 10.26 10.30 10.40 10.46 Temperature coefficient ofVoc: -0.24%/'C Panel Efficiency(%) 20.6 20.9 212 21.4 21.7 Temperature coefficient of Ix: 0.04%/°C d Values at standard test conditions(SIC:air mass AM1.5,irradiance 1075W/sgft(1000 WW1 temperature 77'F(25`C).based onaproduction 'The temperature coefficients stated are linear values u spread with a tolerance of Vr &I,u t3%within one watt class.'Where xxx indicates the nominal power class(P .)at STC above. ELECTRICAL DATA @ NMOT Product Code':RECxxxAA LOW LIGHT BEHAVIOUR Nominal Power-P.,(W p) 274 278 282 286 290 Typical low irradiance performance of module at5TC: ^+ Nominal Power Voltage-V,,W(V) 35.5 35.8 36.1 36.4 36.7 mo m Nominal PowerCurrent-I,,,p(A) 7.71 7.76 7.80 7.85 7.88 '°° rf Open CircuitVoltage-Vn(V) 41.6 41.7 41.9 42.0 42.1 g ff f Short CircuitCurrent-I,(A) 826 829 8.32 8.40 8.45 I I N Nominal module o eratin temperature(NMOT:airmassAM1.5.irradiance800W ( pe ft/s([m/s).' 9 P 8 nqe /m2.temperatue68'F120"C.winds ed33 tx 7 Where xxx indicates the nominal power class(P.,,,)at STC above. - ----------------- o. kradiance(W/m°) d ce r s ` ,,, Founded in Norway in 1996,REC is a leading vertically integrated ', f !`' y solar energy company.Through integrated manufacturing from .� Sr 1 J • silicon to wafers,cells,high quality panels and extending to solar .i it "� ► • i � ` solutions,REC provides the world with a reliable source of clean ... • : wwwrecgroup' energy. REC's renowned product quality is supported by the Y .i �A • i : , (� lowest warranty claims rate in the industry.REC is a 8luestar •,, Elkem company with headquarters in Norway and operational ❑� 7., ,7� 4 ,\`(. headquarters in Singapore.REC employs around 2,000 people C +� . r• 7, " 1 M1' worldwide,producingl.SGWofsolar nelsannual( ti, 44 t r .I,' . " pp i i�1 4 i4 Kx It • IRON RIDGE XR100 Rail See Descri Lion / Length :[iH Rail Section Properties Property Value Total Cross-Sectional Area 0.582 in2 — .66 f Section Modulus (X-axis) 0.297 in3 .46 Moment of Inertia (X-axis) 0.390 in4 J L Moment of Inertia (Y-axis) 0.085 in4 Torsional Constant 0.214 in3 Polar Moment of Inertia 0.126 in° 1.99 APPROVED MATERIALS: 2.44 6005-T6, 6005A-161,6105-T5,6N01-T6 2.34 (34,000 PSI YIELD STRENGTH MINIMUM) 58 1 P Clear Part Black Part Description/Length Material Weight Number Number XR-100-132A XR-100-132B XR100, Rail 132'(11 Feet) 7.50 lbs. 6000-Series XR-100-168A XR-100-168B XR100, Rail 168"(14 Feet) 9.55 lbs. XR-100-204A XR-100-204B XR100, Rail 204"(17 Feet) Aluminum 11.60 lbs. vi.1 IRONRIDGE XR100 Bonded Splice ir\di°t• ti XR-100 RAIL t• f 12.0 " . - 11 ,,-- ..„-- 0 X R-100-SP LC-B D -- KIT, XR100 BONDED SPLICE .; 0 1) Splice, XR100, Mill 12" long 2) Screw, Self Drilling 0, ' 1.24 -- ) 63 r— 1.93 y .31 . 1 0 11 illillittP Ili 0.42 .15 He- -; .93 .... - #12-14 TYPE "B"THREAD Property Value Properly Value Material 6000 Series Aluminum Material 300 Series Stainless Steel Finish Mill Finish Clear vl.0 ,.., ,f-- ,,,.....„ , • QvikFooL PRODUCT GUIDE Exploded Product View/B.O.M. - 1 Installation Instructions - 2 euxemptsg, Cut Sheets - 3 04 Specifications -4 Pli •t a.irri. s icti Om., ',....1 , 410 . .,.. „._ .. .._ ,_. ... , . • . _____ , _ i.,.... ,______..___ iirotA,*, .. , 1..**"4'1 111'1. 11, ' rm'''.. ":1'''i ifA • � �yt add e 1 t,I ,I.- t. , i ayl kri t ilt i Q il �L4' bI{ J 4 r. C fits 5S _s . f . ,{i . 0� � i CoFasten Solar 44 '. 1 ° i i .1 `' Ift QuikFoot— Product Guide Exploded Product View, Bill of Materials Materials Needed for Assembly 7 Item No. Description of Material/Part Quantity 1 QuikFoot Base Plate 1 6 2 Fastener(Length to be determined) 2 cit €11vitto,,F3 QuikFoot Flashing 1 �� �:_-- " 4 EPDM Washer 1 O5 L-102-3"Bracket*(other options available) 1 Cip O 6 5/16"EPDM Bonded 18.8 SS Washer 1 7 3/8"Stainless Steel Hex Nut 1 0 3 C) Clie 111.0 Cin Required Tools w C 1I'I1 I L 'v1SQ0 C111t1i.t1 i In k iiiN o'0.-4•0 Ia•4 0 0.i,.4 4 r ♦ 'y 877-859-3947 EcoFasten Solar®All content protected under copyright.All rights reserved.10/09/14 1.1 EcoFasten Solar products are protected by the following U.S.Patents:8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2 4 r s t s f1 QuikFoot- Product Guide 2X 0 .33in [8.38mm] A ;Eli 0 tit II% u Csia) 0 c E • E 0 CNI ' CO ' LO CO %si4441:::::4 alb 0 rit. !MIA — 111111110 1 .50in Lu— c) [38.10mm] 1114 3/8"-16 Stud c E .g E l t� M O• T Q F-M : 1 .5" u QF-L : 1 .75" i S • 1 1 *,-,W-,W,4, 4 ' 4s• ` 1 F 877-859-3947 EcoFasten Solar®All content protected under copyright.All rights reserved.10/09/14 3.1 EcoFasten Solar products are protected by the following U.S.Patents:8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2 '=4} w, — 11 &E. is t `#' QuikFoot— Product Guide Cut Sheets: QFL-812 R.38in [9.53mm] .032in [0.81mm] 1110 immiO CA4. Z te CA 12.00in [304.80m m] r 4 Co) L Oo- 14 3.00in Y11 [76.20mm] 1 I -11 [-- Liu .50in 8.001nNJ [ 12.70mm] [203.20mm] 877-859-3947 EcoFasten Solar®All content protected under copyright.All rights reserved.10/09/14 3.2 EcoFasten Solar products are protected by the following U.S.Patents:8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2 QuikFoot— Product Guide Cut Sheets: Bracket Options-SCL-1 01-3 3/8" ;,..., • A et Li 46 SERRATIONS 0 CO17) ��J ;o 1--. ) .., VJ 1 1 _ 1 7/8" -� R 1/16 M 1/4" o0 --i 3/4" 1---- 1/16" — R.005 R.O10 c / 2X R.01 i 0 60.00° _, 3/8"±.002 1/8„ 0 7/8„ X 82° DETAIL A SCALE 3:1 877-859-3947 EcoFasten Solar®All content protected under copyright.All tights reserved.10/09/14 3.7 EcoFasten Solar products are protected by the following U.S.Patents:8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2 SQUq 4 RF 4 G PV Squared Solar I www pvsquared.coop Phone:413-772-8788 I Fax:413-772-8668 311 Wells St.,Ste.B I Greenfield,MA 01301 4. 4. . 50•.° MA Elec. Lic.A13764 I MA HIC 140077 Dear Town Inspections Officials, Please see our enclosed applications to permit a Solar Photovoltaic System in your jurisdiction. As you are likely aware, PV Squared is a worker-owned-cooperative B-Corp, employing 40+ people in Greenfield. We have installed thousands of PV Systems out of our Greenfield, MA Headquarters since 2002. PV Squared is committed to complying with all Commonwealth laws and regulations. Our worksite guidelines are created with the intention of exceeding all safety, electrical, and building requirements as defined by their respective jurisdictional entities. This includes the work of people from multiple disciplines, including electrical engineering, structural engineering, civil engineering, electricians, construction supervisors, roofers, and their associated helpers. We are a company that values training and education. We make certain that every individual is qualified for the roles and responsibilities that they assume. It is our policy to pay for the employees travel and training time and cost of the education, including CSL and Journeyman and Master Electrician classes. As an electrical contractor we are furthermore guided by the January 30, 2009 Massachusetts Board of State Examiners of Electricians (BSEE)judgements, and rulings that have followed. We pay strict adherence to these mandates and all electrical work is conducted by an electrician and an electrician's apprentice in a 1:1 ratio. We also understand that non-electrical tasks associated with a Solar installation can be completed by non-electrical workers, such as CSLs and others. I have attached our installation policy for your review, as well as a list of example non-electrical tasks. Should you have any questions or concerns regarding this policy or delineation of work, please let us know. We are a learning organization that is always trying to improve on what we do. Respectfully, Maya Fulford Installation Manager