21016 100_102 MAIN STREET permit 6 june 21VCT
FLOORING
Rev Date Description
Project Title This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.Proposed Renovations to the
RETAIL TENANT
SPACE
at
100/102 MAIN STREET
Northampton, Massachusetts
Issue Date:
Drawn By:
Checked By:
Project ID:
Drawing No.
Project North
1 6/6/2021 PERMIT
Sheet Title
Scale:
06/06/2021
JPB
JPB
21-016
AS NOTEDJODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.comPERMIT - 06/06/2021
DN.Ramp downDN.UPUP Display casesElectric ClosetDN.
UP
MECHANICAL
ROOM
ELEVATOR
EXITEXIT
MECHANICAL
ROOM
TENANT SPACE -- N.I.C.
TENANT SPACE -- N.I.C.
NEW TENANT SPACE
RESTROOM
RESTROOM
LOWER LEVEL LOBBY
OFFICE
BASEMENT DEMO PLAN
Scale: 1/4" = 1'-0"1
AREA OF WORK
INFILL EXISTING OPENING
NEW, 1HR RATED WALL
W/ 45MIN RATED DOOR
& FRAME WITH
CLOSER.
LOWER LEVEL, 1ST FLOOR TENANT
PATCH / REPAIR FLOOR AS
REQUIRED AT DEMO'D STAIRS.
DN.
UP
MODELNUMBERTRADENAMEPRODUCTMATERIAL
ex. elecpanelex. elecpanelEXIT
F
PROPOSED FIRST FLOOR PLAN
Scale: 1/4" = 1'-0"2
ADJACENT RETAIL TENANT SPACE -- N.I.C.
AREA OF WORK
1ST FLOOR TENANT
7'-4 1/2"
1'-0" CHASE 6'-1"
6'0" CLEAR, FINISHED
3 1/2"7'-10 1/2"7'-7"7'6" CLEAR, FINISHED3 1/2"1'-6"1'-6"1'-0"3'-6"6"3'-6"ENCLOSURE AT RESTROOM:
WALLS - 2X4 @ 16" OC W/ 1/2" GWB EA. SIDE.
3" MINERAL WOOL OR EQ. SOUND
INSULATION.
CEILING - 2X8 @ 16" OC. 1/2" GWB AT
BATHROOM INTERIOR, 3/4" PLYWOOD AT
TOP. PROVIDE 3" MINERAL WOOL SOUND
INSULATION IN JOIST BAYS.
FINISHED CEILING HT = 7'6" A.F.F.
RESTROOM DOOR - 3'0"X6'8" SOLID
CORE W/ METAL FRAME. ADA
COMPLIANT LEVER HARDWARE,
PRIVACY LOCK. ADA COMPLIANT
CLOSER.1'-9"LINE OF EXIST. SOFFIT,
ABOVE
ENCLOSE EXIST. HVAC
PIPING
ENCLOSE EXIST. HVAC
DUCT WORK & PIPING
EXISTING PARTITION TO
REMAIN
INSTALL NEW SOLID CORE
DOOR IN EXISTING DOOR
FRAME. LEVER PASSAGE
HARDWARE W/ CLOSER.
INFILL FLOOR AT DEMO'D STAIRS --
2X10 @ 16" OC W/ 3/4" PLYWOOD
SUBFLOOR LEVEL W/ EXISTING,
ADJACENT FLOOR SURFACE.
EXISTING CONC.
SUBFLOOR TO
REMAIN
EXIST. WOOD FLOORING TO REMAIN
EXISTING DISPLAY
BOX TO REMAIN
NEW GLAZING & DOOR OR
MODIFY EXISTING AT
INTERIOR OF DISPLAY BOX.
NEW ENTRY DOOR & NEW
POSTS TO MATCH EXISTING AT
STOREFRONT -- SEE SHEET
A-2
INSTALL NEW INSULATED,
TEMPERED GLAZING AT
EXISTING STOREFRONT AND MODIFIED AREAS, TYPICAL
EXISTING STAIRS TO
LOWER LEVEL TO REMAIN
EXISTING STAIRS TO
UPPER LEVEL TENANTS
TO REMAIN
INSTALL HORN/STROBE FIRE
ALARM AT NEW RESTROOM. TIE
INTO EXISTING BUILDING
SYSTEM.
PATCH / REPAIR
FLOOR AS REQ'D AT
REMOVED RAISED
DISPLAY.
FLOOR PLANS
A-1threshold
Rev Date Description
Project Title This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.Proposed Renovations to the
RETAIL TENANT
SPACE
at
100/102 MAIN STREET
Northampton, Massachusetts
Issue Date:
Drawn By:
Checked By:
Project ID:
Drawing No.
Project North
1 6/6/2021 PERMIT
Sheet Title
Scale:
06/06/2021
JPB
JPB
21-016
AS NOTEDJODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.comPERMIT - 06/06/2021
EXTERIOR
ELEVATION
DETAILS
A-2
SIGNAGE100 Main Street
NEW DOOR, SIDELITE AND TRANSOM
3'-0"1'-8"8'-0"±7'-10"1'-4"
EXISTING STOREFRONT -
DISPLAY BOX TO REMAIN.
INSTALL NEW INSULATED,
TEMEPERED GLAZING IN
EXISTING OPENINGS.
EXISTING STOREFRONT TO
REMAIN. INSTALL NEW
INSULATED, TEMPERED
GLAZING IN EXISTING
OPENING.
EXTERIOR ELEVATION AT STOREFRONT
Scale: 1/2" = 1'-0"1
EXISTING ENTRY TO UPPER LEVEL
TENANTS TO REMAIN
EXISTING SIGNAGE BOARD TO REMAIN. NEW
STOREFRONT SIGNAGE BY FUTURE TENANT -
T.B.D.
NEW 3'0"X8'0" ALUMINUM STOREFRONT
DOOR, SIDELIGHT, AND TRANSOM.
INSULATED, TEMPERED GLAZING. PUSH BAR
HARDWARE. ADA CLOSER.
EXISTING SIGN LIGHTING TO REMAIN
NEW ALUMINUM DOOR, TRANSOM, AND SIDELITE
STOREFRONT. 3'0"X8'0" DOOR W/ ±1'4" SIDELIGHT &
±1'8" HIGH TRANSOM. INSULATED, TEMPERED
GLAZING. PUSH BAR HARDWARE AT DOOR. ADA
CLOSER.
1'-4"3'-0"2"2"2"
3 1/4"
NEW INSULATED, TEMPERED GLASS DISPLAY WINDOW IN EXISTING, MODIFIED OPENING.
1/2" WOOD
4X4 WOOD POST. ANCHOR TO STRUCTURAL
WOOD FRAMING ABOVE.ALIGNOCTAGONAL COLUMN TO MATCH EXISTING IN
DETAILING AND FINISH
NEW INSULATED, TEMPERED
GLASS DISPLAY WINDOW IN
EXISTING OPENING.
NEW INSULATED, TEMPERED
GLASS DISPLAY WINDOW IN
EXISTING OPENING.
NEW INSULATED, TEMPERED GLASS
DISPLAY WINDOW IN EXISTING
OPENING.
WOOD BLOCKING AS
NEEDED
1/2" PLYWOOD
OCTAGONAL COLUMN TO MATCH EXISTING IN
DETAILING AND FINISH
ALIGNEXIST EXIST
EXIST
EXISTING WINDOW DISPLAY BOX TO REMAIN
MODIFY EXISTING GLASS & DOOR OR INSTALL NEW AS
REQUIRED BY INSTALLATION OF NEW ENTRY DOOR.
ENLARGED PLAN AT NEW ENTRY DOOR
Scale: 1 1/2" = 1'-0"2
CODE:
DESCRIPTION-
THE PROPOSED PROJECT ELIMINATES AN ABANDONED STAIR WAY BETWEEN THE FRONT / MAIN STREET AND
LOWER LEVEL LOBBY. THE STAIR SPACE IS RETURNED TO THE EXISTING MAIN STREET LEVEL RETAIL SPACE.
THE EXISTING STOREFRONT IS MODIFIED RELOCATING THE ENTRY DOOR TO ALIGN WITH AN EXISTING
STOREFRONT DISPLAY TO REMAIN.
THE LOWER LEVEL FOR THE TENANT RETAIL SPACE WILL BE DIVIDED BY INFILLING AN EXISTING CASED
OPENING. A NEW HALL IN THE LOCATION OF THE EXISTING, REMOVED STAIR WILL BE CREATED ALLOWING
EGRESS / ENTRANCE TO THE LOWER LEVEL OF THE TENANT SPACE TO AND FROM THE LOWER LEVEL LOBBY.
A NEW RESTROOM WILL BE CONSTRUCTED AT THE STREET LEVEL RETAIL SPACE.
USE GROUP-
EXISTING - M, MERCANTILE
PROPOSED - M, MERCANTILE
AREA- EXISTING - APPROX. 2,879 SF (±1,674 AT STREET LEVEL, ±1,205 AT LOWER LEVEL)
PROPOSED - APPROX. 2,308 SF (±1,829 AT STREET LEVEL, ±429 AT LOWER LEVEL)
GENERAL NOTES -
RELOCATE / RECONNECT LIFE SAFETY ALARMS AND LIGHTING AS AFFECTED BY RENOVATIONS. CONNECT TO
EXISTING BUILDING SYSTEMS.
RELOCATE SPRINKLER HEADS IN AREA OF DEMOLISHED STAIRS TO LOWER LEVEL AS AFFECTED BY
RENOVATIONS.
ADDITIONAL UPGRADES OR IMPROVEMENTS BY FUTURE TENANT, T.B.D.
Rev Date Description
Project Title This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.Proposed Renovations to the
RETAIL TENANT
SPACE
at
100/102 MAIN STREET
Northampton, Massachusetts
Issue Date:
Drawn By:
Checked By:
Project ID:
Drawing No.
Project North
1 6/6/2021 PERMIT
Sheet Title
Scale:
06/06/2021
JPB
JPB
21-016
AS NOTEDJODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.comPERMIT - 06/06/2021
UP
DN.Ramp downDN.UPUP Display casesElectric ClosetDN.
UP
GARAGE
MECHANICAL
ROOM
ELEVATOR
LOWER LEVEL DEMO PLAN
Scale: 1/4" = 1'-0"1
DEMO EXISTING DOOR,
WALL & ASSOCIATED
MATERIALS
AREA OF WORK
DEMO EXISTING CASED OPENING.
INFILL OPENING
DEMO EXISTING STAIRS
AND ASSOCIATED
MATERIALS
LOWER LEVEL, 1ST FLOOR TENANT
PATCH / REPAIR CEILING
AS REQUIRED BY
INSTALLATION OF NEW
PLUMBING AT 1ST
FLOOR RESTROOM
ABOVE
DN.
DN.
UPex. elecpanelex. elecpanelFIRST FLOOR DEMO PLAN
Scale: 1/4" = 1'-0"2
PREP FLOOR AS REQUIRED FOR
CONSTRUCTION OF NEW
RESTROOM
DEMO FLOOR AS REQUIRED
FOR INSTALLATION OF NEW
PLUMBING CHASE AT REST
ROOM
DEMO EXISTING RAISED FLOOR
DEMO SLAT WALL EXTENSION
EVEN WITH STAIR WALL
DEMO EXISTING WALL.
MODIFIY SPRINKLER PIPE
AND HEAD AS REQUIRED FOR NEW LAYOUT.
DEMO STAIRS AND
ASSOCIATED
MATERIALS
DEMO STOREFRONT
AND ASSOCIATED
MATERIALS
DEMO GLAZING AT STOREFRONT. PREP
FOR INSTALLATION OF NEW,
INSULATED GLAZING
MODIFY LOW WALL @
STOREFRONT &
DISPLAY AS
REQUIRED FOR NEW
ENTRY
EX. DISPLAY TO
REMAIN
DEMO OR MODIFY GLASS AND
GLASS DOOR AT DISPLAY BOX
TO REMAIN
PREP DOOR
FRAME FOR
RE-INSTALLATION
OF NEW DOOR
EXISTING STAIRS
TO LOWER LEVEL
TO REMAIN
EXISTING STAIRS
TO UPPER LEVEL
TENANT SPACES
TO REMAIN
ADJACENT RETAIL TENANT SPACE -- N.I.C.
AREA OF WORK
1ST FLOOR TENANT SPACE
DEMO PLANS
D-1