Loading...
21016 100_102 MAIN STREET permit 6 june 21VCT FLOORING Rev Date Description Project Title This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.Proposed Renovations to the RETAIL TENANT SPACE at 100/102 MAIN STREET Northampton, Massachusetts Issue Date: Drawn By: Checked By: Project ID: Drawing No. Project North 1 6/6/2021 PERMIT Sheet Title Scale: 06/06/2021 JPB JPB 21-016 AS NOTEDJODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.comPERMIT - 06/06/2021 DN.Ramp downDN.UPUP Display casesElectric ClosetDN. UP MECHANICAL ROOM ELEVATOR EXITEXIT MECHANICAL ROOM TENANT SPACE -- N.I.C. TENANT SPACE -- N.I.C. NEW TENANT SPACE RESTROOM RESTROOM LOWER LEVEL LOBBY OFFICE BASEMENT DEMO PLAN Scale: 1/4" = 1'-0"1 AREA OF WORK INFILL EXISTING OPENING NEW, 1HR RATED WALL W/ 45MIN RATED DOOR & FRAME WITH CLOSER. LOWER LEVEL, 1ST FLOOR TENANT PATCH / REPAIR FLOOR AS REQUIRED AT DEMO'D STAIRS. DN. UP MODELNUMBERTRADENAMEPRODUCTMATERIAL ex. elecpanelex. elecpanelEXIT F PROPOSED FIRST FLOOR PLAN Scale: 1/4" = 1'-0"2 ADJACENT RETAIL TENANT SPACE -- N.I.C. AREA OF WORK 1ST FLOOR TENANT 7'-4 1/2" 1'-0" CHASE 6'-1" 6'0" CLEAR, FINISHED 3 1/2"7'-10 1/2"7'-7"7'6" CLEAR, FINISHED3 1/2"1'-6"1'-6"1'-0"3'-6"6"3'-6"ENCLOSURE AT RESTROOM: WALLS - 2X4 @ 16" OC W/ 1/2" GWB EA. SIDE. 3" MINERAL WOOL OR EQ. SOUND INSULATION. CEILING - 2X8 @ 16" OC. 1/2" GWB AT BATHROOM INTERIOR, 3/4" PLYWOOD AT TOP. PROVIDE 3" MINERAL WOOL SOUND INSULATION IN JOIST BAYS. FINISHED CEILING HT = 7'6" A.F.F. RESTROOM DOOR - 3'0"X6'8" SOLID CORE W/ METAL FRAME. ADA COMPLIANT LEVER HARDWARE, PRIVACY LOCK. ADA COMPLIANT CLOSER.1'-9"LINE OF EXIST. SOFFIT, ABOVE ENCLOSE EXIST. HVAC PIPING ENCLOSE EXIST. HVAC DUCT WORK & PIPING EXISTING PARTITION TO REMAIN INSTALL NEW SOLID CORE DOOR IN EXISTING DOOR FRAME. LEVER PASSAGE HARDWARE W/ CLOSER. INFILL FLOOR AT DEMO'D STAIRS -- 2X10 @ 16" OC W/ 3/4" PLYWOOD SUBFLOOR LEVEL W/ EXISTING, ADJACENT FLOOR SURFACE. EXISTING CONC. SUBFLOOR TO REMAIN EXIST. WOOD FLOORING TO REMAIN EXISTING DISPLAY BOX TO REMAIN NEW GLAZING & DOOR OR MODIFY EXISTING AT INTERIOR OF DISPLAY BOX. NEW ENTRY DOOR & NEW POSTS TO MATCH EXISTING AT STOREFRONT -- SEE SHEET A-2 INSTALL NEW INSULATED, TEMPERED GLAZING AT EXISTING STOREFRONT AND MODIFIED AREAS, TYPICAL EXISTING STAIRS TO LOWER LEVEL TO REMAIN EXISTING STAIRS TO UPPER LEVEL TENANTS TO REMAIN INSTALL HORN/STROBE FIRE ALARM AT NEW RESTROOM. TIE INTO EXISTING BUILDING SYSTEM. PATCH / REPAIR FLOOR AS REQ'D AT REMOVED RAISED DISPLAY. FLOOR PLANS A-1threshold Rev Date Description Project Title This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.Proposed Renovations to the RETAIL TENANT SPACE at 100/102 MAIN STREET Northampton, Massachusetts Issue Date: Drawn By: Checked By: Project ID: Drawing No. Project North 1 6/6/2021 PERMIT Sheet Title Scale: 06/06/2021 JPB JPB 21-016 AS NOTEDJODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.comPERMIT - 06/06/2021 EXTERIOR ELEVATION DETAILS A-2 SIGNAGE100 Main Street NEW DOOR, SIDELITE AND TRANSOM 3'-0"1'-8"8'-0"±7'-10"1'-4" EXISTING STOREFRONT - DISPLAY BOX TO REMAIN. INSTALL NEW INSULATED, TEMEPERED GLAZING IN EXISTING OPENINGS. EXISTING STOREFRONT TO REMAIN. INSTALL NEW INSULATED, TEMPERED GLAZING IN EXISTING OPENING. EXTERIOR ELEVATION AT STOREFRONT Scale: 1/2" = 1'-0"1 EXISTING ENTRY TO UPPER LEVEL TENANTS TO REMAIN EXISTING SIGNAGE BOARD TO REMAIN. NEW STOREFRONT SIGNAGE BY FUTURE TENANT - T.B.D. NEW 3'0"X8'0" ALUMINUM STOREFRONT DOOR, SIDELIGHT, AND TRANSOM. INSULATED, TEMPERED GLAZING. PUSH BAR HARDWARE. ADA CLOSER. EXISTING SIGN LIGHTING TO REMAIN NEW ALUMINUM DOOR, TRANSOM, AND SIDELITE STOREFRONT. 3'0"X8'0" DOOR W/ ±1'4" SIDELIGHT & ±1'8" HIGH TRANSOM. INSULATED, TEMPERED GLAZING. PUSH BAR HARDWARE AT DOOR. ADA CLOSER. 1'-4"3'-0"2"2"2" 3 1/4" NEW INSULATED, TEMPERED GLASS DISPLAY WINDOW IN EXISTING, MODIFIED OPENING. 1/2" WOOD 4X4 WOOD POST. ANCHOR TO STRUCTURAL WOOD FRAMING ABOVE.ALIGNOCTAGONAL COLUMN TO MATCH EXISTING IN DETAILING AND FINISH NEW INSULATED, TEMPERED GLASS DISPLAY WINDOW IN EXISTING OPENING. NEW INSULATED, TEMPERED GLASS DISPLAY WINDOW IN EXISTING OPENING. NEW INSULATED, TEMPERED GLASS DISPLAY WINDOW IN EXISTING OPENING. WOOD BLOCKING AS NEEDED 1/2" PLYWOOD OCTAGONAL COLUMN TO MATCH EXISTING IN DETAILING AND FINISH ALIGNEXIST EXIST EXIST EXISTING WINDOW DISPLAY BOX TO REMAIN MODIFY EXISTING GLASS & DOOR OR INSTALL NEW AS REQUIRED BY INSTALLATION OF NEW ENTRY DOOR. ENLARGED PLAN AT NEW ENTRY DOOR Scale: 1 1/2" = 1'-0"2 CODE: DESCRIPTION- THE PROPOSED PROJECT ELIMINATES AN ABANDONED STAIR WAY BETWEEN THE FRONT / MAIN STREET AND LOWER LEVEL LOBBY. THE STAIR SPACE IS RETURNED TO THE EXISTING MAIN STREET LEVEL RETAIL SPACE. THE EXISTING STOREFRONT IS MODIFIED RELOCATING THE ENTRY DOOR TO ALIGN WITH AN EXISTING STOREFRONT DISPLAY TO REMAIN. THE LOWER LEVEL FOR THE TENANT RETAIL SPACE WILL BE DIVIDED BY INFILLING AN EXISTING CASED OPENING. A NEW HALL IN THE LOCATION OF THE EXISTING, REMOVED STAIR WILL BE CREATED ALLOWING EGRESS / ENTRANCE TO THE LOWER LEVEL OF THE TENANT SPACE TO AND FROM THE LOWER LEVEL LOBBY. A NEW RESTROOM WILL BE CONSTRUCTED AT THE STREET LEVEL RETAIL SPACE. USE GROUP- EXISTING - M, MERCANTILE PROPOSED - M, MERCANTILE AREA- EXISTING - APPROX. 2,879 SF (±1,674 AT STREET LEVEL, ±1,205 AT LOWER LEVEL) PROPOSED - APPROX. 2,308 SF (±1,829 AT STREET LEVEL, ±429 AT LOWER LEVEL) GENERAL NOTES - RELOCATE / RECONNECT LIFE SAFETY ALARMS AND LIGHTING AS AFFECTED BY RENOVATIONS. CONNECT TO EXISTING BUILDING SYSTEMS. RELOCATE SPRINKLER HEADS IN AREA OF DEMOLISHED STAIRS TO LOWER LEVEL AS AFFECTED BY RENOVATIONS. ADDITIONAL UPGRADES OR IMPROVEMENTS BY FUTURE TENANT, T.B.D. Rev Date Description Project Title This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed in the space below. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.Proposed Renovations to the RETAIL TENANT SPACE at 100/102 MAIN STREET Northampton, Massachusetts Issue Date: Drawn By: Checked By: Project ID: Drawing No. Project North 1 6/6/2021 PERMIT Sheet Title Scale: 06/06/2021 JPB JPB 21-016 AS NOTEDJODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.comPERMIT - 06/06/2021 UP DN.Ramp downDN.UPUP Display casesElectric ClosetDN. UP GARAGE MECHANICAL ROOM ELEVATOR LOWER LEVEL DEMO PLAN Scale: 1/4" = 1'-0"1 DEMO EXISTING DOOR, WALL & ASSOCIATED MATERIALS AREA OF WORK DEMO EXISTING CASED OPENING. INFILL OPENING DEMO EXISTING STAIRS AND ASSOCIATED MATERIALS LOWER LEVEL, 1ST FLOOR TENANT PATCH / REPAIR CEILING AS REQUIRED BY INSTALLATION OF NEW PLUMBING AT 1ST FLOOR RESTROOM ABOVE DN. DN. UPex. elecpanelex. elecpanelFIRST FLOOR DEMO PLAN Scale: 1/4" = 1'-0"2 PREP FLOOR AS REQUIRED FOR CONSTRUCTION OF NEW RESTROOM DEMO FLOOR AS REQUIRED FOR INSTALLATION OF NEW PLUMBING CHASE AT REST ROOM DEMO EXISTING RAISED FLOOR DEMO SLAT WALL EXTENSION EVEN WITH STAIR WALL DEMO EXISTING WALL. MODIFIY SPRINKLER PIPE AND HEAD AS REQUIRED FOR NEW LAYOUT. DEMO STAIRS AND ASSOCIATED MATERIALS DEMO STOREFRONT AND ASSOCIATED MATERIALS DEMO GLAZING AT STOREFRONT. PREP FOR INSTALLATION OF NEW, INSULATED GLAZING MODIFY LOW WALL @ STOREFRONT & DISPLAY AS REQUIRED FOR NEW ENTRY EX. DISPLAY TO REMAIN DEMO OR MODIFY GLASS AND GLASS DOOR AT DISPLAY BOX TO REMAIN PREP DOOR FRAME FOR RE-INSTALLATION OF NEW DOOR EXISTING STAIRS TO LOWER LEVEL TO REMAIN EXISTING STAIRS TO UPPER LEVEL TENANT SPACES TO REMAIN ADJACENT RETAIL TENANT SPACE -- N.I.C. AREA OF WORK 1ST FLOOR TENANT SPACE DEMO PLANS D-1