Kiosk Plan SetGENERAL BUILDING SPECIFICATIONS:Notice - Austin Mohawk & Co. LLC claimsproprietary rights in the information disclosedon this drawing. It is issued in confidence forengineering information only and may not beused, in whole or in part, to manufactureanything whether or not shown hereon,reproduced or disclosed to anyone withoutdirect written permission fromAustin Mohawk & Co., LLCAUSTIN MOHAWK & CO.,LLC2175 BEECHGROVE PLACEUTICA, NY 13501PHONE: 315.793.3000TOLL FREE: 1.800.765.3110FAX: 315.793.9370WEBSITE: www.austinmohawk.comE-mail: info@austinmohawk.comJOB NO:SHEET:SCALE:LOCATION:DRAWN BY:MOD NO:COLOR:DATE:TITLE:CERTIFICATIONQUOTE NO:JOHN W KENNEDY CO
990 WATERMAN AVE
EAST PROVIDENCE, RI 0291412'-0" X 26'-0"STEEL BUILDING0210052-NORTH HAMPTON, MASTB1226H3FPSEE SPECIFICATIONS03.23.21CDANOT TO SCALE1 OF 6LIGHTING:A. GENERAL:ELECTRICAL:DOORS:WINDOWS:WALL PANELS:BASE/FLOOR:FRAME CONSTRUCTION:DIMENSIONS:310141159421Framing shall be 14 GA or heavier mechanical tube. All joints shall be MIG welded. Lifting lugs shall be provided at roof level.Wall panels shall have 18 ga exterior face, 3" wall thickness, 2" rigid board polyisocyanurate insulation (R-13) and 3/4" plywood throughout, and a 18 GA interior face, 18 ga panels shall be galvanealed and shall beMIG welded into place.Building shall be wired according to 2020 National Electric Code. All circuits shall be wired within 1/2" dia surface mount EMT conduit with home runs to wire trough above power integrity cabinet and included shall be (Qty-18) GFCI protected20 amp duplex receptacles with tester. (Qty-5) Duplex data port shall be installed with 3/4" dia surface mounted empty EMT conduit with pull string and conduit home runs to j-box near data rack. A recessed data port shall be installed abovecounter for (time clock by others) with 1/2" dia surface mounted empty EMT conduit with pull string and conduit home run to j-box near data rack. (Qty-1) Outdoor WP-GFCI shall be installed at Elevation 'A' for future cooler.(Qty-6) Lighting shall be a 48" LED light fixture controlled by wall switch near doors. (Qty-6) Exterior Mirada sconce lighting fixture shall be provided (shipped loose for install by others on-site), wired and prep by Austin controlled by wall switch near door.12'-0" wide x 26'-0" long with a 143 1/4" nominal outside height. Interior dimension from floor to ceiling shall be 102".Pre-assemble building of steel construction.CEILING:8Interior ceiling shall be a panel system providing smooth flat interior, constructed from 20 ga pre-finished white steel with rigid polyisocyanurate insulation (R-6.5) above.Attendant Room:(Qty-1) Swing door (36" x 84") shall be commercial grade steel and steel frame with a hydraulic closer. Door shall have (3) three stainless steel hinges, keyed lever lockset with removable core type cylinder compatible with Best core exterior andinterior push button lock cylinder. Door lock shall be best access system, no substitution, cylinder model #1E76C181 RP1, thumb turn cylinder model #1E7A4-C181-RP3. Door shall be same color as building. Door shall be ADA compliant.(Qty-1) Outdoor 20K multi-zone (208/230V) inverter heat-pump system with:(Qty-1) Ceiling cassette (24"x24") heat pump unit #1, 9K Btu/h (cooling/heating), (CFM: 207-335) in Customer room.(Qty-1) Ceiling cassette (24"x24") heat pump heat pump unit #2, 9K Btu/h (cooling/heating), (CFM: 207-335) in Attendant room.(Qty-1) Duct branch from each cassette to diffuser to Restroom.HVAC:156ROOF:Exterior roof shall be constructed from 20 ga, G-60 interlocking pan sections. Sections shall be 3" high with varying widths. Roof shall have 24" ACM fascia and roof shall drain into full perimeter gutter system withdownspouts.(Qty-2) GFCI protected 20 amp duplex receptacle with tester. RECEPTACLE:(Qty-1) Exhaust fan shall be thru-wall 180 CFM, 120V.EXHAUST FAN:FIXTURES:B. RESTROOM:171816COUNTERS:12DOOR:(Qty-1) Swing door (36" x 84") shall be commercial grade steel and steel frame that is hung using a three hinge system. Hydraulic closer and lockset included. Door lock shall be best access system, no substitution,cylinder model #1E76C181 RP1, thumb turn cylinder model #1E7A4-C181-RP3. Door handles to be lever type. Door shall be painted to match building. Door shall be ADA compliant.REVISION STATUS OF SHEETS1REVSHD2DCustomer Room:(Qty-1) Swing door (36" x 84") shall be commercial grade steel and steel frame with a hydraulic closer. Door shall have (3) three stainless steel tamper resistant hinges, keyed lever lockset with removable core type cylinder compatible withBest core exterior and interior push button lock cylinder. Door lock shall be best access system, no substitution, cylinder model #1E76C181 RP1, thumb turn cylinder model #1E7A4-C181-RP3. Door shall be same color as building. Doorshall be ADA compliant.7FINISH:Surfaces shall be painted using an epoxy/urethane prime to paint system designed to withstand salt spray and freeze thaw testing. Building color shall be Tannery (SW 4004). Fascia/gutter and downspouts shall besame color as building exterior. Interior color shall match exterior.3D20Concrete pad foundation is by others in the field. Building is to be anchored to concrete pad using 1/2" diameter minimum anchor bolt, (qty-1) per anchor clip, (qty-10) anchor clips total.FOUNDATION:21Customer room shall have (qty-1) 37 1/2" wide by 12" deep x 1" stainless steel counter. Attendant room shall have (qty-1) three-piece (U-shape) 24" deep x 1 1/2" stainless steel counter with (qty-1) ShureSafe (Model #670150) thru-wall transactiondrawer with stainless steel finish and with a bullet resistant level 3 faceplate insert. Attendant room counters supplied with counter top drop wire grommet(s).QTY-1 BUILDING4C5CBuilding shall be constructed on a 6" mechanical tube frame encapsulated with a protective undercoating paint. Concrete pad by others on-site shall serve as the floor.Fixed windows shall be 3/4" insulated clear tempered safety glass. Window with speak-thru at (Elevation 'A', see sheet 2 of 6) shall be 1/2" clear laminated tempered glass. Glass shall be framed to building using clear anodized aluminum framingsystem. (Qty-1) Speak-thru shall be installed at location shown at Elevation 'A', see sheet 2 of 6. (Qty-1) Speak-thru shall be installed at location shown at (Interior partition 'E', see sheet 2 of 6) shall be 1/4" clear tempered safety glass. A film shall besupplied by 'Big Y' and applied to glass on-site by 'Big Y'.REVISIONSDESCRIPTIONREVBYDATE04.22.21CDAAUPDATED REVISION STATUS OF SHEETS; REVISED NOTES 8, 9, 10, 13 AND 16 PERCUSTOMER MARK-UPS DATED 04.12.21A(Qty-1) Heater shall be a QMark wall heater with 13,500 BTU, 240V. Unit shall be shipped loose and installed by others in field. HEATER:19(Qty-1) Heater shall be a QMark wall heater with 13,500 BTU, 240V. Unit shall be shipped loose and installed by others in field. HEATER:136DExterior of building shall have Brick Veneer (Red Blend Smooth Thin Brick), installed as shown at Elevation Views, see sheet 2 of 6.BRICK VENEER:The following restroom fixtures (shipped loose) are supplied only, (all plumbing and mounting of fixtures will be on site by others):- (Qty-1) ADA elongated toilet- (Qty-1) 42" Grab bar- (Qty-1) ADA wall mount lavatory- (Qty-1) 36" Grab bar- (Qty-1) ADA lavatory faucet- (Qty-1) 18" Grab bar- (Qty-1) Toilet tissue holder- (Qty-1) Hand dryerAAAA04.29.21CDABUPDATED REVISION STATUS OF SHEETSCCC05.13.21CDACUPDATED REVISION STATUS OF SHEETS; REVISED NOTE 7, 11 AND 1505.27.21CDADUPDATED REVISION STATUS OF SHEETS; REVISED NOTE 10DCUSTOMER APPROVALAPPROVED AS SUBMITTEDAPPROVED AS NOTEDREVISE AND RESUBMITDATE:SIGNED:THESE DRAWINGS AND SPECIFICATIONS HAVE BEEN PRODUCED IN ACCORDANCE WITHAUSTIN MOHAWK & COMPANY LLC'S PROPOSAL AND THE PROJECT DESIGN. THEPROJECT WILL BE MANUFACTURED IN ACCORDANCE TO THIS INFORMATION ASSUBMITTED. THE SECURING OF BUILDING PERMITS AND COMPLIANCE WITHAPPROPRIATE BUILDING CODES IS THE RESPONSIBILITY OF THE PURCHASER OF THEBUILDING AND NOT THE RESPONSIBILITY OF AUSTIN MOHAWK.3aD
Notice - Austin Mohawk & Co. LLC claimsproprietary rights in the information disclosedon this drawing. It is issued in confidence forengineering information only and may not beused, in whole or in part, to manufactureanything whether or not shown hereon,reproduced or disclosed to anyone withoutdirect written permission fromAustin Mohawk & Co., LLCAUSTIN MOHAWK & CO.,LLC2175 BEECHGROVE PLACEUTICA, NY 13501PHONE: 315.793.3000TOLL FREE: 1.800.765.3110FAX: 315.793.9370WEBSITE: www.austinmohawk.comE-mail: info@austinmohawk.comJOB NO:SHEET:SCALE:LOCATION:DRAWN BY:MOD NO:COLOR:DATE:TITLE:CERTIFICATIONQUOTE NO:JOHN W KENNEDY CO
990 WATERMAN AVE
EAST PROVIDENCE, RI 0291412'-0" X 26'-0"STEEL BUILDING0210052-NORTH HAMPTON, MASTB1226H3FPSEE SPECIFICATIONS03.23.21CDANOT TO SCALE2 OF 6FASCIA/GUTTER W/ 6"PERIMETER OVERHANG102"CEILINGHEIGHTA.F.G.ELEVATION AELEVATION BELEVATION CELEVATION D143 1/4"NOMINALHEIGHT26'-0" OUT-TO-OUT BUILDING WALL26'-0" OUT-TO-OUT BUILDING WALL12'-0" OUT-TO-OUTBUILDING WALL72"ȭRESTROOMEXHAUST FAN49"(TYP)28 3/4"37"(TYP)6" O.H.TYP6" O.H.TYP6" O.H. TYP6" O.H. TYPCEILING MOUNTHVAC UNIT36"SWINGDOORTRANSACTIONDRAWER102"CEILINGHEIGHTA.F.G.34"A.F.G.60"A.F.G.HVAC (CONDENSER)(OUTDOOR UNIT)TRANSACTION DRAWEREXTERIORDOOR28 3/4"ȭ(4) LIFT LUGSAT ROOF LEVEL24"(TYP)24"(TYP)24"6" O.H.TYP6"34" MAXA.F.F.TRANSACTION DRAWERCOUNTER34" MAXA.F.F.29" (27") MINKNEE CLEARANCEA.F.F.SECTION A-A102"CEILINGHEIGHTA.F.G.TOP OFCONCRETE PADTOP OFCONCRETE PAD5" HIGH3/4" INSULATED CLEARTEMPERED SAFETY GLASS5 5/16" DIASPEAK-THRU102"CEILINGHEIGHTA.F.G.66 1/2"ACCESS BOX FORCEILING MOUNT HVAC UNIT, TYP FOR 26" O.H.TYP6" O.H.TYP24"(TYP)INTERIOR PARTITION 'E'12'-0"10"84 3/4"84"DOORHEIGHT(TYP)102"CEILINGHEIGHTA.F.G.ATTENDANT DOOR36"SWINGDOORTOP OFCONCRETE PADTOP OFCONCRETE PADTOP OF CONCRETE PADINTERIOR PARTITION 'F'12'-0"20"74 3/4"84"DOORHEIGHT(TYP)102"CEILINGHEIGHTA.F.G.RESTROOMDOOR36"SWINGDOOR34 3/8"34 3/8"31"31 1/2"BB24"6"T.O. COUNTER34" MAXA.F.F.CUSTOMER TRANSACTIONCOUNTERCOUNTER34" MAXA.F.F.SECTION B-B102"CEILINGHEIGHTA.F.G.TOP OF CONCRETE PADT.O. COUNTER34" MAXA.F.F.12"ATTENDANT COUNTERTRANSACTION WINDOW WITH COUNTERSERVICE OPENINGSIZE: 24" W x 12"H(1/4" CLEAR TEMPERED SAFETY GLASS)49"(TYP)16" CLEARANCEFOR OVERHEAD MONITOR25" DEEP102"CEILINGHEIGHTA.F.G.3/4" INSULATED CLEARTEMPERED SAFETY GLASS1/2" CLEAR LAMINATED TEMPERED SAFETY GLASS w/SPEAK-THRUSURFACE MOUNT J-BOX FOR CAMERA(CAMERA BY OTHERS ON-SITE)SURFACE MOUNT J-BOX FOR CAMERA(CAMERA BY OTHERS ON-SITE)(EXHAUST FAN)SURFACE MOUNT J-BOX FOR CAMERA(CAMERA BY OTHERS ON-SITE)SURFACE MOUNT J-BOX FOR CAMERA(CAMERA BY OTHERS ON-SITE)SURFACE MOUNT J-BOX FOR CAMERA(CAMERA BY OTHERS ON-SITE)BRICK VENEER PANELS(TYP)26'-2" OUT-TO-OUT BRICK VENEER12'-2" OUT-OUT-OUTBRICK VENEER26'-2" OUT-TO-OUT BRICK VENEER12'-0" OUT-TO-OUTBUILDING WALL12'-2" OUT-OUT-OUTBRICK VENEER112 1/4"5 5/16" DIASPEAK-THRU60"A.F.F.ȭGFCI RECEPTACLE FOROVERHEAD MONITORA24"1/4" CLEAR TEMPEREDSAFETY GLASSREVISIONSDESCRIPTIONREVBYDATE04.22.21CDAAREVISED INTERIOR PARTITION 'E' PER CUSTOMER MARK-UPS DATED 04.12.21A111"MIRADA WALL SCONCE6 PLACES, (TYPICAL)MIRADA WALL SCONCEMIRADA WALL SCONCE121 5/16"A.F.G.MIRADA WALLSCONCE, (TYP)MIRADA WALL SCONCE(TYP)(MIRADA WALL SCONCE)MIRADA WALL SCONCE(TYP)MIRADA WALL SCONCE(TYP)MIRADA WALL SCONCE(TYP)52"CCCCCCC05.13.21CDACREVISED ELEVATION VIEWS AND SECTION VIEWS, ADDED MIRADA LIGHTS111"WP-GFI (20 AMP) FORFUTURE ICE COOLER18"A.F.G.D05.27.21CDADREVISED ELEVATION 'A', ADDED OUTDOOR WP-GFCICUSTOMER APPROVALAPPROVED AS SUBMITTEDAPPROVED AS NOTEDREVISE AND RESUBMITDATE:SIGNED:THESE DRAWINGS AND SPECIFICATIONS HAVE BEEN PRODUCED IN ACCORDANCE WITHAUSTIN MOHAWK & COMPANY LLC'S PROPOSAL AND THE PROJECT DESIGN. THEPROJECT WILL BE MANUFACTURED IN ACCORDANCE TO THIS INFORMATION ASSUBMITTED. THE SECURING OF BUILDING PERMITS AND COMPLIANCE WITHAPPROPRIATE BUILDING CODES IS THE RESPONSIBILITY OF THE PURCHASER OF THEBUILDING AND NOT THE RESPONSIBILITY OF AUSTIN MOHAWK.
Notice - Austin Mohawk & Co. LLC claimsproprietary rights in the information disclosedon this drawing. It is issued in confidence forengineering information only and may not beused, in whole or in part, to manufactureanything whether or not shown hereon,reproduced or disclosed to anyone withoutdirect written permission fromAustin Mohawk & Co., LLCAUSTIN MOHAWK & CO.,LLC2175 BEECHGROVE PLACEUTICA, NY 13501PHONE: 315.793.3000TOLL FREE: 1.800.765.3110FAX: 315.793.9370WEBSITE: www.austinmohawk.comE-mail: info@austinmohawk.comJOB NO:SHEET:SCALE:LOCATION:DRAWN BY:MOD NO:COLOR:DATE:TITLE:CERTIFICATIONQUOTE NO:JOHN W KENNEDY CO
990 WATERMAN AVE
EAST PROVIDENCE, RI 0291412'-0" X 26'-0"STEEL BUILDING0210052-NORTH HAMPTON, MASTB1226H3FPSEE SPECIFICATIONS03.23.21CDANOT TO SCALE3 OF 6BPLAN VIEWACD924"U-SHAPEDWORKCOUNTER34" MAXA.F.F., (TYP)27'-0" OUT-TO-OUT FASCIAFASCIAOVERHANGAREAANCHOR CLIP10X12'-0"OUTTOOUTBUILDING26'-0" OUT-TO-OUT BUILDING18TREMOTE CONTROL HVAC T-STATCUSTOMER ROOMDUPLEX18" A.F.F.13'-0"OUTTOOUTFASCIADOWNSPOUT3'-0"DOORTRANSACTION DRAWERDOWNSPOUT2XRESTROOMHVACCEILINGCASSETTEUNITHALF-WALL PIPE CHASETO HIDE PLUMBING (7" WIDE CAVITY SPACE)(PLUMBING FIXTURES AND PLUMBING BY OTHERS ON-SITE)GFCI DUPLEX18" A.F.F.BRANCH DUCTCEILINGDIFFUSER18"ȭ18"DUPLEX18" A.F.F.167" CAVITY3'-0"DOORREST ROOM SECTION33" - 36"A.F.F.39"-41"A.F.F.18"MIN42" MIN12"MAX17"MINIMUMSEATHEIGHT54" MIN39" - 41"PIPE CHASE HIDES PLUMBING& VALVES, ETC. INSIDE FALSEWALL PROVIDES ACCESS TOPLUMBING39"18" GRAB BAR42" GRAB BAR114"6"102"CEILINGHEIGHTA.F.F.7" CAVITY144"6'-7 1/2"ȭDATA RACK (BY OTHERS)QUADPLEX18" A.F.F.9'-7 1/4"8'-9 1/4"3'-0"DOOR111171 1/2"37 1/2"67 1/4"12"GFCI DUPLEX18" A.F.F.DUPLEX18" A.F.F.POWER INTEGRITYINTEGRATED POWERAND CONTROL CABINET(BY OTHERS ON-SITE)CABLEGROMMET4X11111111GFCI DUPLEX18" A.F.F.DUPLEX18" A.F.F.DUPLEX DATAPORT, TYP 5X18" A.F.F.HAND DRYER19ALARM PANEL (BY OTHERS)6'-0"10"9CUSTOMER COUNTER(37 1/2" W x 12" DPDUPLEX18" A.F.F.DUPLEX18" A.F.F.
DUPLEX
18" A.F.F.QUADPLEX18" A.F.F.DUPLEX18" A.F.F.DUPLEX18" A.F.F.GFCIDUPLEX18" A.F.F.GFCI DUPLEX18" A.F.F.GFCI DUPLEX18" A.F.F.GFCIDUPLEX18" A.F.F.VEETER ROOTINSIDE POWER INTEGRITY(BY OTHERS)PUBLIC VIDEOMONITOR RUN HDMI(BY OTHERS)QUADPLEX6" ABOVE COUNTER(40" A.F.F.)CIRCUIT BREAKER SHALL BEGFCI PROTECTED(CIRCUIT BREAKER BY OTHERS)BEAN TO CUP(BY OTHERS)ALARM KEYPAD(BY OTHERS)DOOR ALARM CONTACT(BY OTHERS)DOOR JAMB CAM(BY OTHERS)ALARM SIREN(BY OTHERS)10'-10"FIRE EXTINGUISHER 40 BC(BY OTHERS)NITROGEN RELEASE BOTTLE FORFIRE SUPPRESSION SYSTEM BELOW COUNTER(BY OTHERS)24"EXTERIOR CAM(TYP, 5X)CAM BY OTHERS)&$0GLASS BREAK DETECTOR027,216(162524"TIME CLOCK (BY OTHERS)w/RECESSED DATA PORT (BY AUSTIN MOHAWK)HOLD UP BUTTON (BY OTHERS)OVER HEAD MONITORFOR FUELING CAMERAS, FEED WITH HDMI (BY OTHERS)(SEE SHEET 2 OF 6, SECTION A-AFOR GFCI DUPLEX RECEPTACLE FOR OVERHEAD MONITOR)NOTES:1. POS #1, POS #2 AND LOTTERY MACHINES NOT SHOWN ON COUNTER SPACE FOR CLARITY FOR COUNTER PLAN CLARITY, SEE SHEET 3a OF 62. EXTERIOR J-BOXES (2X4) FOR EXTERIOR CAMERAS ARE SURFACE MOUNT FOR ON-SITE CAMERA INSTALL BY OTHERS. A SURFACE MOUNT J-BOX (2X4) SHALL BE LOCATED AT INTERIOR SIDE OPPOSITE OF EXTERIOR J-BOX LOCATION WITH A EMPTY 1/2" DIA EMT CONDUIT RUN TO WIRE TROUGH WITH PULL STRING3. SURFACE MOUNTED 2X4 J-BOX MOUNTED ON CEILING FOR DOOR JAMB CAM4. ALL PLUMBING, DRAIN WASTE VENT AND SUPPLY PIPE BY OTHERS ON-SITE5. ALL GRAB BARS AND FIXTURES SHIPPED LOOSE, INSTALLED BY OTHERS ON-SITE6. LAVATORY, TOILET SHALL BE ADA COMPLIANTATTENDANT ROOMHOLD UP BUTTON (BY OTHERS)EF12ACCESSPANEL6"18"18"1414ACCESSPANEL6"18"18"ROOF MOUNTEDOUTDOOR UNITHVACCEILINGCASSETTEUNITSPOWER AND DATA (50" A.F.F.) BY OTHERS, INSTALLED WITHIN 12"OF ALARM PANELFOR BEAN TO CUPNEMA L6-20R6" ABOVE COUNTER(40" A.F.F.)CIRCUIT BREAKER SHALL BEGFCI PROTECTED(CIRCUIT BREAKER BY OTHERS)&$0(5$(BY OTHERS)PROVIDE A COLD WATER-LINE WITH A 1/2"ISOLATION VALVE AND TERMINATECONNECTIONS TO BREWER WITH MALEADAPTER 1/4" X 1/2" NTPF(BY OTHERS ON-SITE)MILLWORK 34" MAX A.F.F.(BY OTHERS ON-SITE)REVISIONSDESCRIPTIONREVBYDATE04.22.21CDAAREVISED PLAN VIEW PER CUSTOMER MARK-UPS DATED 04.12.21AB04.29.21CDABREVISED PLAN VIEW PER CUSTOMER MARK-UPS DATED 04.27.21; RELOCATEDRECEPTACLES ABOVE MILL WORKGFCI DUPLEX
DUPLEX18" A.F.F.POSSIBLE LOCATION FOR DROP SAFEAND LOTTERY CABINET ABOVE (BY OTHERS)MIRADA LIGHTTYP, QTY 6CD05.13.21CDACREVISED PLAN VIEW, ADDED MIRADA LIGHTSCUSTOMER APPROVALAPPROVED AS SUBMITTEDAPPROVED AS NOTEDREVISE AND RESUBMITDATE:SIGNED:THESE DRAWINGS AND SPECIFICATIONS HAVE BEEN PRODUCED IN ACCORDANCE WITHAUSTIN MOHAWK & COMPANY LLC'S PROPOSAL AND THE PROJECT DESIGN. THEPROJECT WILL BE MANUFACTURED IN ACCORDANCE TO THIS INFORMATION ASSUBMITTED. THE SECURING OF BUILDING PERMITS AND COMPLIANCE WITHAPPROPRIATE BUILDING CODES IS THE RESPONSIBILITY OF THE PURCHASER OF THEBUILDING AND NOT THE RESPONSIBILITY OF AUSTIN MOHAWK.WP-GFCI (20 AMP) FORFUTURE ICE COOLER
CTEXTERIORTRANSACTIONWINDOWCUSTOMER COUNTER(37 1/2" W x 12" DPGFCI DUPLEX18" A.F.F.HOLD UP BUTTON(BY OTHERS)VOLUMATIC(BY OTHERS)UNDER POS #1 OR POS#2ATTENDANT ROOMPOS #1(BY OTHERS)POS #2(BY OTHERS)ADBTIME CLOCK(BY OTHERS)54" A.F.F.LOTTERY TICKETDISPLAY ABOVE COUNTER(BY OTHERS)HOLD UP BUTTON(BY OTHERS)CIGARETTE RACKUNDER COUNTER(BY OTHERS)Notice - Austin Mohawk & Co. LLC claimsproprietary rights in the information disclosedon this drawing. It is issued in confidence forengineering information only and may not beused, in whole or in part, to manufactureanything whether or not shown hereon,reproduced or disclosed to anyone withoutdirect written permission fromAustin Mohawk & Co., LLCAUSTIN MOHAWK & CO.,LLC2175 BEECHGROVE PLACEUTICA, NY 13501PHONE: 315.793.3000TOLL FREE: 1.800.765.3110FAX: 315.793.9370WEBSITE: www.austinmohawk.comE-mail: info@austinmohawk.comJOB NO:SHEET:SCALE:LOCATION:DRAWN BY:MOD NO:COLOR:DATE:TITLE:CERTIFICATIONQUOTE NO:JOHN W KENNEDY CO
990 WATERMAN AVE
EAST PROVIDENCE, RI 0291412'-0" X 26'-0"STEEL BUILDING0210052-NORTH HAMPTON, MASTB1226H3FPSEE SPECIFICATIONS05.27.21CDANOT TO SCALE3a OF 6COUNTER PLAN FOR CLARITYCUSTOMER APPROVALAPPROVED AS SUBMITTEDAPPROVED AS NOTEDREVISE AND RESUBMITDATE:SIGNED:THESE DRAWINGS AND SPECIFICATIONS HAVE BEEN PRODUCED IN ACCORDANCE WITHAUSTIN MOHAWK & COMPANY LLC'S PROPOSAL AND THE PROJECT DESIGN. THEPROJECT WILL BE MANUFACTURED IN ACCORDANCE TO THIS INFORMATION ASSUBMITTED. THE SECURING OF BUILDING PERMITS AND COMPLIANCE WITHAPPROPRIATE BUILDING CODES IS THE RESPONSIBILITY OF THE PURCHASER OF THEBUILDING AND NOT THE RESPONSIBILITY OF AUSTIN MOHAWK.REVISIONSDESCRIPTIONREVBYDATE05.27.21CDADADDED SHEETWP-GFCI (20 AMP) FORFUTURE ICE COOLERTWO DRAWER FILE CABINETUNDER COUNTER(BY OTHERS)LOTTERY MACHINE(BY OTHERS)LOTTERY MACHINE(BY OTHERS)HEATERHAND DRYERHEATERPOWER INTEGRITYINTEGRATED POWERAND CONTROL CABINET(BY OTHERS ON-SITE)VEETER ROOTINSIDE POWER INTEGRITY(BY OTHERS)REMOTE CONTROL HVAC T-STATCABLE GROMMETCABLE GROMMETCABLE GROMMETCABLE GROMMETNOTE:THE INTERIOR TRANSACTION WINDOW WILL BE THE PRIMARY AND THE EXTERIORTRANSACTION WINDOW WILL BE THE SECONDARY.INTERIORTRANSACTIONWINDOW
Notice - Austin Mohawk & Co. LLC claimsproprietary rights in the information disclosedon this drawing. It is issued in confidence forengineering information only and may not beused, in whole or in part, to manufactureanything whether or not shown hereon,reproduced or disclosed to anyone withoutdirect written permission fromAustin Mohawk & Co., LLCAUSTIN MOHAWK & CO.,LLC2175 BEECHGROVE PLACEUTICA, NY 13501PHONE: 315.793.3000TOLL FREE: 1.800.765.3110FAX: 315.793.9370WEBSITE: www.austinmohawk.comE-mail: info@austinmohawk.comJOB NO:SHEET:SCALE:LOCATION:DRAWN BY:MOD NO:COLOR:DATE:TITLE:CERTIFICATIONQUOTE NO:JOHN W KENNEDY CO
990 WATERMAN AVE
EAST PROVIDENCE, RI 0291412'-0" X 26'-0"STEEL BUILDING0210052-NORTH HAMPTON, MASTB1226H3FPSEE SPECIFICATIONS03.23.21CDANOT TO SCALE4 OF 65"LIFT LUG6"OVERHANG19"24"20 GA PERIMETER GUTTER20GA ROOF DECK PAN FASTENED USING #10 X 3/4" TEKSCREW W/NEOPRENE WASHER (3) PER DECK PAN OR 4" O.C.20 GA GALV FASCIA BRACEFASCIA BRACE FASTENED TO DECK PAN RIBUSING #10 SCREWS(3) PER BRACEBRACE CONNECTIONS USING #10 SCREWS(2) PER CONNECTIONACM FASCIACONNECTED TO TOP AND BOTTOMHANGING ANGLE WITH #10 SCREW 12" O.C.20 GA GALV HANGING ANGLEATTACHED TO FASCIA BRACE WITH #10 SCREW (2) PER BRACEATTACH 20 GA BOTTOM HANGING ANGLEATTACHED TO GUTTER/FASCIA BRACEWITH #8 SCREW WITH NEOPRENE WASHER 16" O.C.FASCIA/GUTTER FASTENED TOROOF DECK PAN BELLYUSING #10 X 3/4" TEK SCREWSw/NEOPRENE WASHER (12" O.C.)FULLY CAULK PERIMETER20 GA ROOF DECK PANROOF SECTION4"4"18 GA EXTERIOR PANEL4"3"WALL SECTION3"18GA EXTERIOR PANEL2" RIGID BOARDINSULATION (R-13)18GA INTERIOR PANEL3/4" PLYWOODEXTERNAL AND INTERNALPANELS ARE STITCH WELDED1/4" x 2" AT 12" SPACINGSEXTERNAL AND INTERNALPANELS ARE STITCH WELDED1/4" X 1" AT 12" SPACING'SCORNER POST** DENOTES FIELD WORK BY OTHERS.BASEFRAMEFULL WELD ALL AROUND** 3" X 3" X 3/8" X 3" LONG ANCHOR ANGLE WITH (1) 1/2" DIA X ??? HILTIKWIK BOLT TZOR EQUAL ANCHOR EMBEDDED ???? IN MINIMUM2000 PSI MINIMUM CONCRETE(10 TOTAL, SUPPLIED AND INSTALLED BY OTHERS IN THE FIELD)6"4 1/2"ȭ3/4" INSULATED CLEAR TEMPERED SAFETY GLASSGLAZING TAPE1" X 3" X 1/8"ALUMINUM ANGLE1" X 1" X 1/8" ALUMINUM ANGLEGLASS STOPGLASS STOP FASTENED WITH TEK SCREWS18 GA EXTERIOR PANEL18 GA INTERIOR PANEL18 GA INTERIOR PANEL1" SQ STEEL BARWELDED TO BASE FRAMESTITCH WELD 1"EVERY 24" O.C.1/2"20 GA STEEL TRIM FLASHINGTYPICAL AT WINDOWS AND DOORSBRICK VENEER"BITUMINOUS SEALANT" (BY OTHERS)1" SQ STEEL BAR(BRICK RELIEF LEDGE)EXTERNAL PANELS ARE STITCH WELDED1/4" X 1" AT 12" SPACING'S AT VERTICAL POSTSINTERNAL PANELS ARE STITCH WELDED1/4" X 1" AT 12" SPACING'S AT VERTICAL POSTS5"6"OVERHANG19"24"WP L-BODY20 GA GALV FASCIA BRACEBOOT FLASHING20 GA ROOF DECK PANLIGHT SECTIONTYPICAL FOR (6) LOCATIONS4"2"MIRADA LIGHT(SHIPPED LOOSE,INSTALLED ON-SITE BY OTHERS)14 GA FORMED GALVANEALEDLIGHT MOUNTING BRACKETCONNECTED TO FASCIA BRACESWP-JBOXJ-BOX BELOW CEILING12"LIGHT MOUNTING BRACKET(QTY-6)1"1"8"1 7/8"REVISIONSDESCRIPTIONREVBYDATEC05.13.21CDACADDED LIGHT SECTION1 1/2"CUSTOMER APPROVALAPPROVED AS SUBMITTEDAPPROVED AS NOTEDREVISE AND RESUBMITDATE:SIGNED:THESE DRAWINGS AND SPECIFICATIONS HAVE BEEN PRODUCED IN ACCORDANCE WITHAUSTIN MOHAWK & COMPANY LLC'S PROPOSAL AND THE PROJECT DESIGN. THEPROJECT WILL BE MANUFACTURED IN ACCORDANCE TO THIS INFORMATION ASSUBMITTED. THE SECURING OF BUILDING PERMITS AND COMPLIANCE WITHAPPROPRIATE BUILDING CODES IS THE RESPONSIBILITY OF THE PURCHASER OF THEBUILDING AND NOT THE RESPONSIBILITY OF AUSTIN MOHAWK.1 1/2"1"
Notice - Austin Mohawk & Co. LLC claimsproprietary rights in the information disclosedon this drawing. It is issued in confidence forengineering information only and may not beused, in whole or in part, to manufactureanything whether or not shown hereon,reproduced or disclosed to anyone withoutdirect written permission fromAustin Mohawk & Co., LLCAUSTIN MOHAWK & CO.,LLC2175 BEECHGROVE PLACEUTICA, NY 13501PHONE: 315.793.3000TOLL FREE: 1.800.765.3110FAX: 315.793.9370WEBSITE: www.austinmohawk.comE-mail: info@austinmohawk.comJOB NO:SHEET:SCALE:LOCATION:DRAWN BY:MOD NO:COLOR:DATE:TITLE:CERTIFICATIONQUOTE NO:JOHN W KENNEDY CO
990 WATERMAN AVE
EAST PROVIDENCE, RI 0291412'-0" X 26'-0"STEEL BUILDING0210052-NORTH HAMPTON, MASTB1226H3FPSEE SPECIFICATIONS03.23.21CDANOT TO SCALE5 OF 6BREFLECTIVE CEILING LAYOUTACD12'-0"OUTTOOUTBUILDING26'-0" OUT-TO-OUT BUILDINGCUSTOMER ROOMATTENDANT ROOMRESTROOMBRANCH DUCTCEILINGDIFFUSER6'-7 1/2" I.D.9'-7 1/4" I.D.8'-9 1/4" I.D.11111111PUBLIC VIDEOMONITOR RUN HDMI(BY OTHERS)&$0GLASS BREAK DETECTOR027,216(1625&$0(5$(BY OTHERS)27 3/8"CEILINGPANEL104 1/4" CEILING PANEL114 1/4" CEILING PANEL78 1/2" CEILING PANEL27 3/8"CEILINGPANEL27 3/8"CEILINGPANEL27 3/8"CEILINGPANEL27 3/8"CEILINGPANEL11'-6"I.D.BROOF LAYOUTACD20 GA STEEL DECK PAN PROFILE(14) @ 12"(02) @ 16"(03) @ 15 5/8"2 15/16"5/8"3/8"3/4"7/16"3"FINISHSIDEH-FRAME20GA CAPOVER H-FRAME20GA CAPOVER H-FRAME16"12"12"P16P12P12BRACE 'B'TYP, QTY 832"32"30"15 5/8"12"12"12"12"15 5/8"1 3/8"15 1/2"12"12"12"12"12"12"12"12"16"LIFT LUG4XACM FASCIAP16P15.625P12P12P12P12P15.625P12P12P12P12P12P12P12P12TYP3/4"1 1/4"FINISHED SIDE (WHITE)SECTION C-CNOTE:- 20 GA STEEL CEILING PANELS TO BE INSULATED WITH (R-6.5) RIGID BOARD PANELSCCINSULATION126 1/8"BRACE 'A'TYP, QTY 1612'-0"OUTTOOUTBUILDING314 7/8" OUT-TO-OUT DECK147"OUTTOOUTDECK26'-0" OUT-TO-OUT BUILDING320" OUT-TO-OUT PERIMETER GUTTER324" OUT-TO-OUT ACM FASCIA152"OUTTOOUTPERIMETERGUTTER156"OUTTOOUTACM FACIA1 1/2"1 1/2" (TYP)HVACCEILINGCASSETTEUNIT1111ACCESSPANEL6"18"18"1414ACCESSPANEL6"18"18"ROOF MOUNTEDHVAC OUTDOOR UNITHVACCEILINGCASSETTEUNITHVACCEILINGCASSETTEUNITHVACCEILINGCASSETTEUNITH-FRAME LAYOUT(QTY-2)20 3/4"5/8"TYP5/8"TYPSECTION C-CH-FRAME PARTS LIST1 1/4" x 1 1/4" x 1/8" STEEL TUBE @ 3" 3" x 3" x 1/8" STEEL TUBE @ 28"3" x 3" x 1/8" STEEL TUBE @ 147"DESCRIPTION321ITEMQTY443" x 1/4" STEEL BAR @ 4 1/2"4CLITEM 1ITEM 1ITEM 2ITEM 3ITEM 4ITEM 3ITEM 434"7/8"4 1/2"1/4"3"7/8"4 1/2"1/4"CLP15.625CAPSLOPEDCAPSLOPED
20GA CAPOVER H-FRAME20GA CAPOVER H-FRAMECAP
SLOPED
CAP
SLOPED
ROOFSUPPORTBEAM(TYP)H-FRAMEROOF MOUNT(OUTDOOR HVAC INVERTER UNIT)32"32 1/2"22"38 5/8"MIRADALIGHTTYP, QTY 6NOTE:- MIRADA LIGHTS SHALL BE SUPPORTED WITH 14 GA BLOCKING WITH J-BOX LOCATED BEHIND ACM, SEE SHEET 4 OF 6 (LIGHT SECTION)1 1/2"REVISIONSDESCRIPTIONREVBYDATE05.13.21CDACREVISED ROOF LAYOUT, ADDED MARADA LIGHTSCUSTOMER APPROVALAPPROVED AS SUBMITTEDAPPROVED AS NOTEDREVISE AND RESUBMITDATE:SIGNED:THESE DRAWINGS AND SPECIFICATIONS HAVE BEEN PRODUCED IN ACCORDANCE WITHAUSTIN MOHAWK & COMPANY LLC'S PROPOSAL AND THE PROJECT DESIGN. THEPROJECT WILL BE MANUFACTURED IN ACCORDANCE TO THIS INFORMATION ASSUBMITTED. THE SECURING OF BUILDING PERMITS AND COMPLIANCE WITHAPPROPRIATE BUILDING CODES IS THE RESPONSIBILITY OF THE PURCHASER OF THEBUILDING AND NOT THE RESPONSIBILITY OF AUSTIN MOHAWK.88147"51 1/2"38"51 1/2"3"3"63 1/8"28"34"12X(1)22X(2)AA20 3/4"20 3/4"63 1/8"CL34X44X1 1/4"(TYP)CLCL4 1/4"4 1/4"
BWIRING VIEWACD24"U-SHAPEDWORKCOUNTER34" MAXA.F.F., (TYP)EXHAUST FAN(EF)TCUSTOMER ROOMGFCI(R3)TRANSACTION DRAWERRESTROOMHVACCEILINGCASSETTEUNIT #2GFCI-R20DIFFUSERDATA RACK (BY OTHERS)GFCI(R18) / R19POWER INTEGRITYINTEGRATED POWERAND CONTROL CABINET(BY OTHERS ON-SITE)R2DUPLEX DATAPORT, TYP 5X18" A.F.F.HAND DRYERALARM PANEL (BY OTHERS)GFCI-R21GFCI-R17VEETER ROOTINSIDE POWER INTEGRITY(BY OTHERS)PUBLIC VIDEOMONITOR RUN HDMI(BY OTHERS)ALARM KEYPAD(BY OTHERS)DOOR ALARM CONTACT(BY OTHERS)ALARM SIREN(BY OTHERS)FIRE EXTINGUISHER 40 BC(BY OTHERS)EXTERIOR CAM(TYP, 5X)CAM BY OTHERS)&$0GLASS BREAK DETECTOR027,216(1625&$0(5$(BY OTHERS)HOLD UP BUTTON (BY OTHERS)HOLD UP BUTTON (BY OTHERS)VOLUMATIC(BY OTHERS)OVER HEAD MONITORFOR FUELING CAMERAS, FEED WITH HDMI (BY OTHERS)ATTENDANT ROOMNotice - Austin Mohawk & Co. LLC claimsproprietary rights in the information disclosedon this drawing. It is issued in confidence forengineering information only and may not beused, in whole or in part, to manufactureanything whether or not shown hereon,reproduced or disclosed to anyone withoutdirect written permission fromAustin Mohawk & Co., LLCAUSTIN MOHAWK & CO.,LLC2175 BEECHGROVE PLACEUTICA, NY 13501PHONE: 315.793.3000TOLL FREE: 1.800.765.3110FAX: 315.793.9370WEBSITE: www.austinmohawk.comE-mail: info@austinmohawk.comJOB NO:SHEET:SCALE:LOCATION:DRAWN BY:MOD NO:COLOR:DATE:TITLE:CERTIFICATIONQUOTE NO:JOHN W KENNEDY CO
990 WATERMAN AVE
EAST PROVIDENCE, RI 0291412'-0" X 26'-0"STEEL BUILDING0210052-NORTH HAMPTON, MASTB1226H3FPSEE SPECIFICATIONS03.23.21CDANOT TO SCALE6 OF 6R4R6R8/R9R5GFCI(R7)R10R14R15GFCI(R16)ALL CIRCUITS WILL BE WIRED WITH #12 AWG STRANDED 600V THHN INSULATED WIRE WITHINSURFACE MOUNT EMT CONDUIT UNLESS OTHERWISE SPECIFIED911CIRCUITNUMBERCIRCUIT PANEL SCHEDULEALL CIRCUITS ROUTED TO WIRE TROUGH ABOVE POWER INTEGRITY CABINETELECTRICAL COMPONENTCIRCUITNUMBER751324GFCI(R1), R2, R5, R6 - 20AHEATER (H1) - 40AGFCI(R3), R4 - 20A681012S3, L3, L4 - 20AGFCI(R7), R8, R9, R10 - 20AS1, S2, L1, L2- 20A131514GFCI(R21) - 20AS4, L5, L6, EF - 20AHVAC DISC.,HVAC #1, T-STAT #1,HVAC #2, T-STAT #2 - 20A EAGFCI(R17) - 20AHEATER(H2)S4S1S3TIME CLOCKw/RECESSED DATA PORT (BY OTHERS)WIRE TROUGH (4" X 4" X 36") ABOVE POWER INTEGRITY CABINETMOUNTED TO WALL (BOTTOM OF TROUGH AT 7'-6" A.F.F.)L2L1L5L6L3L4CKT#3CKT#5CKT#6CKT#4(240V)HEATER(H1)CKT#16CKT#11(240V)CKT#10CKT#14CKT#8HVAC DISCONNECTTO ROOF TOPOUTDOOR INVERTERPUMP CKT#9WP-GFCI(R22)(TO ROOF ADJACENT TO DISC.)TOT-STAT #2CKT#9NOTES: 1. POS #1, POS #2 AND LOTTERY MACHINES NOT SHOWN ON COUNTER SPACE FOR CLARITY, SEE SHEET 3a OF 6 FOR CLARITY 2. EXTERIOR J-BOXES (2X4) FOR EXTERIOR CAMERAS ARE SURFACE MOUNT FOR ON-SITE CAMERA INSTALL BY OTHERS. A SURFACE MOUNT J-BOX (2X4) SHALL BE LOCATED AT INTERIOR SIDE OPPOSITE OF EXTERIOR J-BOX LOCATION WITH A EMPTY 3/4" DIA EMT CONDUIT RUN BACK TO 6" X 6" X 12" J-BOX WITH PULL STRING ABOVE DATA RACK 3. SURFACE MOUNTED 4X4 J-BOX MOUNTED ON CEILING FOR DOOR JAMB CAM 4. LIGHTS SHALL BE LOCATED IN BUILDING AS SHOWN 5. ALL RECEPTACLES SHALL BE 18" A.F.F. UNLESS OTHERWISE SPECIFIED 6. TOP OF LIGHT SWITCHES: (CUSTOMER ROOM 36" A.F.F.) (ATTENDANT ROOM AND RESTROOM 42" A.F.F.) 7. ALL COMPONENTS, CONDUITS AND J-BOXES ARE SURFACE MOUNTED UNLESS OTHERWISE SPECIFIED 8. ALL CIRCUITS SHALL BE WIRED WITHIN 1/2" DIA SURFACE MOUNT EMT CONDUIT WITH HOME RUNS TO WIRE TROUGH ABOVE POWER INTEGRITY CABINET 9. ALL DATA CABLING SHALL BE CAT6A (BY OTHERS ON-SITE)10. ALL DATA PORTS SHALL HAVE 3/4" DIA EMT CONDUIT WITH PULL STRINGS BACK TO 6" X 6" X 12" J-BOX ABOVE DATA RACKCKT#131521336661010101010GFCI(R12), R13, R14 - 20ACKT#15HEATER (H2) - 40AHAND DRYER - 20AWP-GFCI(R22) - 20AGFCI(R20) - 20AHVACCEILINGCASSETTEUNIT #1ACCESSPANELACCESSPANELTOT-STAT #1TREMOTECONTROLHVACT-STAT #15TO ROOF TOPOUTDOOR INVERTERPUMP CKT#9CKT#2S5S2(3)(3)16GFCI(R1)11155CKT#17GFCI(R11)RECEPTACLE FOR OVERHEAD MONITORR13CKT#77ROOF MOUNT HVAC OUTDOOR UNIT10"CKT#12QUADPLEX6" ABOVE COUNTER(40" A.F.F.),CIRCUIT BREAKER SHALL BEGFCI PROTECTED(CIRCUIT BREAKER BY OTHERS)BEAN TO CUP(BY OTHERS)GFCI(R23) / R24FOR BEAN TO CUPNEMA L6-20R6" ABOVE COUNTER(40" A.F.F.),CIRCUIT BREAKER SHALL BEGFCI PROTECTED(CIRCUIT BREAKER BY OTHERS)PROVIDE A COLD WATER-LINE WITH A 1/2"ISOLATION VALVE AND TERMINATECONNECTIONS TO BREWER WITH MALEADAPTER 1/4" X 1/2" NTPF(BY OTHERS ON-SITE)APAP= ACCESS POINT (BY OTHERS) PROVIDE (1) CAT6A FROM DATA RACK TO THIS LOCATION FOR WIRELESS ACCESS POINTDOOR JAMB CAM (BY OTHERS)(J-BOX PROVIDED ABOVE DOOR BY AUSTIN MOHAWK)EXTERIOR CAMCAM BY OTHERS)EXTERIOR CAMCAM BY OTHERS)EXTERIOR CAMCAM BY OTHERS)REMOTE CONTROL HVAC T-STAT #2EXTERIOR CAMCAM BY OTHERS)GFCI(R12)R2517GFCI(R11) - 20A1819GFCI(R16) - 20A20GFCI(R18), R19 - 20AGFCI(R23), R24 - 20AR25 - 20ACKT#18CKT#20NOTE: CIRCUIT PANEL SCHEDULE SHALL BE COORDINATED WITH POWER INTEGRITY BY OTHERS ON-SITECKT#1MILLWORK, 34" MAX A.F.F.(BY OTHERS ON-SITE)R13 & DATA PORTFOR VOLUMATIC SAFE18" A.F.F.J-BOX LOCATED AT CEILINGFOR DOOR JAMB CAM 6" X 6 X 12" J-BOX FOR 3/4" DIA EMT CONDUIT DATA CABLING CONNECTIONSFASCIA/GUTTER102"CEILINGHEIGHTA.F.G.INTERIOR ELEVATION 'C'26'-0" OUT-TO-OUT BUILDING WALL26'-2" OUT-TO-OUT BRICK VENEERJ-BOX FOR CAMERA84"6"8"POWERINTEGRITYPANEL(BEYOND)SERVICEWINDOW105 1/4"CUSTOMER ROOM115 1/4"ATTENDANT ROOM79 1/2"RESTROOM2X4 J-BOXESFOR CAMERA(TYP)2X4 J-BOXESFOR CAMERA6" X 6" X 6" J-BOX (9" BELOW CEILING)FOR DATA / CAMERA CONDUITS,ALL CONDUITS SUPPLIED W/ PULL STRINGS105 1/4"115 1/4"79 1/2"DATA RACK(BY OTHERS)R18 / R19GFCI(R1)R2REVISIONSDESCRIPTIONREVBYDATE04.22.21CDAAREVISED WIRING VIEW AND PANEL SCHEDULE PER CUSTOMER MARK-UPSDATED 04.12.21; ADDED INTERIOR ELEVATION 'C' FOR CLARITYAA 40"A.F.F.R26721R15, R26 - 20A22CKT#21B04.29.21CDABREVISED WIRING VIEW, PANEL SCHEDULE AND INTERIOR ELEV 'C' PERCUSTOMER MARK-UPS DATED 04.27.21; ADDED RECEPTACLES FOR LOTTERYMACHINEB34"A.F.F.34" A.F.F.(TYP)6"MIRADA LIGHTTYP, QTY 6(WP CONDUIT ABOVE ROOFTO EACH LIGHT AT FASCIA)S5, ML1 THRU ML6 - 20AML1ML2ML3ML4ML5ML605.13.21CDACREVISED WIRING VIEW, ADDED MIRADA LIGHTSCCUSTOMER APPROVALAPPROVED AS SUBMITTEDAPPROVED AS NOTEDREVISE AND RESUBMITDATE:SIGNED:THESE DRAWINGS AND SPECIFICATIONS HAVE BEEN PRODUCED IN ACCORDANCE WITHAUSTIN MOHAWK & COMPANY LLC'S PROPOSAL AND THE PROJECT DESIGN. THEPROJECT WILL BE MANUFACTURED IN ACCORDANCE TO THIS INFORMATION ASSUBMITTED. THE SECURING OF BUILDING PERMITS AND COMPLIANCE WITHAPPROPRIATE BUILDING CODES IS THE RESPONSIBILITY OF THE PURCHASER OF THEBUILDING AND NOT THE RESPONSIBILITY OF AUSTIN MOHAWK.23WP-GFCI - 20A24WP-GFCI (20 AMP) FORFUTURE ICE COOLERCKT#23D05.27.21CDADREVISED WIRING VIEW, PANEL SCHEDULE, ADDED WP-GFCI FOR ICE COOLERPER CUSTOMER MARK-UPS DATED 05.20.21CKT#19SS5CKT#22TO ML1 THRU ML6TO S5(CKT#22)TO S5(CKT#22)TO S5(CKT#22)TO S5(CKT#22)TO S5(CKT#22)TO S5(CKT#22)