Stamped PE Calcs - Selig, DanielFreedom Forever LLC 43445 Business Park Dr Suite 110 Temecula, CA 92590 Attn.: To Whom It May Concern re job:DANIEL SELIG 67 LIBERTY ST, NORTHHAMPTON, MA 01062 Design Criteria: Code:2015 IBC w/ 780 CMR ASCE 7-10 Live Load:20 psf Ult Wind Speed:117 mph Exposure Cat:B Ground Snow:40 psf Min Roof Snow:35 Current Renewables Engineering Inc. Professional Engineer info@currentrenewableseng.com 3/19/2021 The following calculations are for the structural engineering design of the photovoltaic panels and are valid only for the structural info referenced in the stamped plan set. The verification of such info is the responsibility of others. After review, I certify that the roof structure has sufficient structural capacity for the applied PV loads. All mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Date :3/19/2021 Job Code: DANIEL SELIG 2 of 6 Roof Properties: Roof Type = Roof Pitch (deg) = Mean Roof Height (ft) = Attachment Trib Width (ft) = Attachment Spacing (ft) = Framing Type = Framing Size = Framing OC Spacing (in.) = Section Thickness, b (in.) = Section Depth, d (in.) = Section Modulus, Sx (in.^3) = Moment of Inertia, Ix (in.^4) = Framing Span (ft) = Deflection Limit D+L (in.) = Deflection Limit S or W (in.) = Attachments Pattern = Framing Upgrade = Sister Size = Wood Species = Wood Fb (psi) = Wood Fv (psi) = Wood E (psi) = CD (Wind) = CD (Snow) = CLS = CM = Ct = CL = Ci = CF = Cfu = Cr = F'b_wind (psi) = F'b_snow (psi) = F'v_wind (psi) = F'v_snow (psi) = M_allowable_wind (lb-ft) = M_allowable_snow (lb-ft) = V_allowable_wind (lbs) = V_allowable_snow (lbs) = E' (psi) = 1139 1501 1700000 1700000 1246 1999 1584 2088 207 207 1734 2781 1977 1825 288 288 1.15 1.15 2751 2539 1.3 1.2 1.00 1.00 1.15 1.15 1.0 1.0 1.6 1.6 1.15 1.15 180 180 1700000 1700000 DF #1 DF #1 1000 1000 Adequate Adequate NA NA 1.33 2.00 Fully Staggered Fully Staggered 10 15 2 3 7.6 13.1 20.8 47.6 1.5 1.5 5.5 7.25 2x6 2x8 24 16 4 4 Rafter Rafter 13 13 2.75 2.75 Flat Material Flat Material 9 9 Roof 1 Roof 2 Date :3/19/2021 Job Code: DANIEL SELIG 3 of 6 Load Calculation: Panels Dead Load (psf) = Roofing Weight (psf) = Decking Weight (psf) = Framing Weight (psf) = Misc. Additional Weight (psf) = Existing Dead Load (psf) = Total Dead Load (psf) = Ground Snow Load, pg (psf) = Min Flat Snow, pf_min (psf) = Min Sloped Snow, ps_min (psf) = Snow Importance Factor, Ic = Exposure Factor, Ce = Thermal Factor, Ct = Flat Roof Snow, pf (psf) = Slope Factore, Cs = Sloped Roof Snow, ps (psf) = Ultimate Wind Speed (mph) = Directionality Factor, kd = Topographic Factor, kzt = Velocity Press Exp Factor, kz = Velocity Pressure, qz (psf) = External Pressure Up, GCp_1 = External Pressure Up, GCp_2 = External Pressure Up, GCp_3 = External Pressure Down, GCp = Design Pressure Up, p_1 (psf) = Design Pressure Up, p_2 (psf) = Design Pressure Up, p_3 (psf) = Design Pressure Down, p (psf) =16.0 16.0 -32.3 -32.3 -51.1 -51.1 0.45 0.45 -17.7 -17.7 -1.55 -1.55 -2.45 -2.45 -0.85 -0.85 0.70 0.70 20.9 20.9 117 0.85 1.0 Roof 1 Roof 2 35 35 Wind Load Calculations: 35 35 1.00 1.00 Roof 1 Roof 2 1.2 1.2 Snow Load Calculations: 40 35 NA 1.0 0.9 5.9 6.9 8.9 9.9 0.9 1.9 1.0 1.0 2.0 2.0 2.0 2.0 Dead Load Calculations: 3.0 Roof 1 Roof 2 Date :3/19/2021 Job Code: DANIEL SELIG 4 of 6 Hardware Checks: Ref. Widthrawal Value, W (lb/in) = (CM = Ct = Ceg = 1.0) CD = Adjusted Widthrawal Value, W' (lb/in) = Lag Penetration, p (in.) = Allowable Widthrawal Force, W'p (lbs) = Applied Uplift Force (lbs) = Uplift DCR = Ref. Lateral Value, Z (lbs) = (CM = Ct = CΔ = Ceg = 1.0) CD = Adjusted Lateral Value, Z' (lbs) = Applied Laeral Force (lbs) = Angle of Resultant Force, α (deg) = Adjusted Interaction Lateral Value, Z'α (lbs) = Lateral DCR = Roof Framing Checks: LC1: D+S Applied Moment (lb-ft) = Applied Shear (lbs) = Allowable Moment (lb-ft) = Allowable Shear (lbs) = Moment DCR = Shear DCR = LC2: D+0.6W Applied Moment (lb-ft) = Applied Shear (lbs) = Allowable Moment (lb-ft) = Allowable Shear (lbs) = Moment DCR = Shear DCR = LC3: D+0.75(S+0.6W) Applied Moment (lb-ft) = Applied Shear (lbs) = Allowable Moment (lb-ft) =1734 2781 1060 1624 424 433 0.27 0.26 0.12 0.09 1734 2781 1584 2088 464 730 185 195 0.88 0.84 0.39 0.30 1246 1999 1139 1501 439 449 Force Checks: Roof 1 Roof 2 1099 1683 853 853 0.08 0.08 65 65 71 71 1.15 1.15 311 311 0.18 0.18 270 270 1064 1064 -194 -194 426 426 2.5 2.5 266 266 1.6 1.6 Lag Screw Checks: Roof 1 Roof 2 Date :3/19/2021 Job Code: DANIEL SELIG 5 of 6 Allowable Shear (lbs) = Moment DCR = Shear DCR = LC4: 0.6D+0.6W Applied Moment (lb-ft) = Applied Shear (lbs) = Allowable Moment (lb-ft) = Allowable Shear (lbs) = Moment DCR = Shear DCR = LC1: D+L Deflection (in.) = Deflection Limit (in.) = Deflection DCR = LC2: S Deflection (in.) = Deflection Limit (in.) = Deflection DCR = LC3: W (Down) Deflection (in.) = Deflection Limit (in.) = Deflection DCR = LC4: W (Up) Deflection (in.) = Deflection Limit (in.) = Deflection DCR = Seismic Check: Wall Weight (psf) = Tributary Wall Area (ft2) = Total Wall Weight (lbs) = Roof Weight (psf) = Roof Area (ft2) = Total Roof Weight (lbs) = Total Existing Weight (lbs) = 1200 20400 6 3500 20809 41209 0.06 0.06 Existing Weight: 17 -0.09 -0.14 1.53 2.30 1.53 2.30 0.06 0.05 0.29 0.29 0.09 0.13 0.45 0.66 1.53 2.30 2.3 3.45 0.07 0.08 Deflection Checks (Service Level): Roof 1 Roof 2 0.17 0.28 0.08 0.06 0.03 0.02 1734 2781 1584 2088 132 177 53 47 0.61 0.58 0.27 0.21 1584 2088 Date :3/19/2021 Job Code: DANIEL SELIG 6 of 6 PV Panel Weight (lbs) = Number of Panels = Total Additional PV Weight (lbs) = (Existing W + Additional W)/(Existing W) =101% The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability: Existing structure is assumed to have been designed and constructed following appropriate codes at time of erection, and assumed to have appropriate permits. The calculations produced are only for the roof framing supporting the proposed PV installation referenced in the stamped planset and were completed according to generally recognized structural analysis standards and procedures, professional engineering and design experience, opinions and judgements. Existing deficiencies which are unknown or were not observable during time of inspection are not included in this scope of work. All PV modules, racking, and mounting equipment shall be designed and installed per manufacturer's approved installation specifications. The Engineer of Record and the engineering consulting firm assume no responsibility for misuse or improper installation. This analysis is not stamped for water leakage. Framing was determined based on information in provided plans and/or photos, along with engineering judgement. Prior to commencement of work, the contractor shall verify the framing sizes, spacings, and spans noted in the stamped plans, calculations, and cert letter (where applicable) and notify the Engineer of Record of any discrepancies prior to starting construction. Contractor shall also verify that there is no damaged framing that was not addressed in stamped plans, calculations, and cert letter (where applicable) and notify the Engineer of Record of any concerns prior to starting construction. Additional PV Weight: 54 10 545 Weight Increase: