32C-239 (10) 1-23 EASTERN AVE BP-2021-0945 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block:32C-239 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: FIRE ALARM SYSTEM BUILDING PERMIT Permit# BP-2021-0945 Project# JS-2021-001617 Est.Cost: $13569.00 Fee: $286.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: CITIZEN SECURITY CORP 373C Lot Size(sq.ft.): 15812.28 Owner: HART JOAN M TRUSTEE Zoning: URC(100)/ Applicant: CITIZEN SECURITY CORP AT: 1-23 EASTERN AVE Applicant Address: Phone: Insurance: 87Center St 1413) 547-6512 Workers Compensation LUDLOWMA01056 ISSUED ON:3/22/2021 0:00:00 TO PERFORM THE FOLLOWING WORK:UPGRADE/MODIFY EXISTING FIRE SYSTEM POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. f i 1 Certificate of Occupancy Signature: 1 l FeeType: Date Paid: Amount: Building 3/22/20210:00:00 $286.00 212 Main Street,Phone(413)587-1240, Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner he/Commonwealth of Massachusetts • FE� 0 Office of Public Safety and Inspections 202/ = Massachusetts State Building Code(780 CMR) Building Permit ppl cation for any Building other than a One-or Two-Family Dwelling rrp is Section For Official Use Only) Building PermitNumber:61)',?f"- r _D„at Applied: Building Official: SECTION 1:LOCATION I-2 3 FpSkrnAvi nlvv+hamp OIo(po Eosiern Ave, I--par•Wrv41t, No.and Street City/Town Zip Code Name of Building(if applicable) b2e�,3 Assessors Map# Block#and/or Lot # SECTION 2:PROPOSED WORK Edition of MA State Code used If New Construction check here 0 or check all that apply in the two rows below Existing Building 0 Repair 0 Alteration 0 Addition 0 Demolition/ 0 (Please fill out and submiti- Appendix 2) Change of Use 0 Change of Occupancy 0 Other ® Specify:Upgrad4m (py i�l ve. si fys�-ei Are building plans and/or construction documents being supplied as part of this permit application? Yes 0 No Is an Independent Structural Engineerin Peer Review required? Yes 0 No B Brief Description of Proposed Work: to .P X IS fi r'i9 f i r Sj - (S [ e C�a 9 NGirrash v e SECTION 3:COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATION,ADDITION,OR CHANGE IN USE OR OCCUPANCY Check here if an Existing Building Investigation and Evaluation is enclosed(See 780 CMR 34) ❑ Existing Use Group(s): Proposed Use Group(s): 2 SECTION 4:BUILDING HEIGHT AND AREA Existing Proposed No.of Floors/Stories(include basement levels)&Area Per Floor(sq.ft.) 3 r Total Area(sq.ft.) and Total Height(ft.) 25,532 cra T{- SECTION 5:USE GROUP(Check as applicable) " b A: Assembly A-1 0 A-2❑ Nightclub 0 A-3 0 A-4 0 A-5 0 B: Business 0 E: Educational 0 F: Factory F-1 0 F2 0 H: High Hazard H-1 0 H-2 0 H-3 0 H-4 0 H-5 0 I: Institutional I-1 0 I-2 0 I-3 0 I-4 0 M: Mercantile 0 R: Residential R-10 R-2 13' R-3 0 R-4 0 S: Storage S-1 0 S-2 0 U: Utility 0 Special Use 0 and please describe below: Special J.Jse Description: SECTION 6:CONSTRUCTION TYPE(Check as applicable) IA 0 IB 0 IIA 0 IIB 0 IIIA ❑ IIIB 0 IV 0 VA 0 VB ❑ SECTION 7:SITE INFORMATION(refer to 780 CMR 105.3 for details on each item) Water Supply: Flood Zone Information: Sewage Disposal: Trench Permit Debris Removal: Public 0 Check if outside Flood Zone 0 Indicate municipal 0 A trench will not be Licensed Disposal Site 0 Private 0 or indentify Zone: or on site system 0 required leor trench or specify: permit is enclosed 0 Railroad right-of-way Hazards to Air Navigation: MA Historic Commission Review Process: Not Applicable M' Is Structure within airport approach area? Is their review completed? or Consent to Build enclosed 0 Yes 0 or No OK Yes 0 No l� SECTION 8:CONTENT OF CERTIFICATE OF OCCUPANCY Edition of Code: Use Group(s): RZ. Type of Construction: Does the building contain an Sprinkler System?: In 0 Special Stipulations: Design Occupant Load per Floor and Assembly space: SECTION 9: PROPERTY OWNER AUTHORIZATION Name and Address of Property Owner g4-J Real Po8ox 91 $ _ Amhers+ rY)Pr 0loot-I Name(Print) No.and Street City/Town Zip Property Owner Contact Information: •Joan 1-1-ay 1- - - yam- 53t8 • cum Title Telephone No.(business) Telephone No. (cell) -mail address If applicable,the roperty owner hereby authorizes: C i fi l . ,cu-v B 7 C.erj -er s+ Ludlow net4 o ►o S Name Street Address City/Town State Zip to apply for and act on the property owner's behalf,in all matters relative to work authorized by this building permit application. SECTION 10:CONSTRUCTION CONTROL(Please fill out Appendix 1) If a building is less than 35,000 cu.ft.of enclosed space and/or not under Construction Control then check here O. Otherwise provide construction control forms(see section 107 in the code)as required. 10.1 Registered Professional Responsible for Construction Control (the professional coordinating document submittals) Name(Registrant) Telephone No. e-mail address Registration Number Street Address City/Town State Zip Discipline Expiration Date 10.2 General Contractor CI 11 WO _ctCAkrIk4 C.m,p Cornp Nam`e� Rbb /fs 3r73CName of PersonIAponsible for Construction License No. and Type if Applicable 8 rj C&-4<r SI- 1-Li d I uw .. 4- 0 I o s C6 Street Address City/Town State Zip H 13-614-7-4si2, - - Ser vi ce.0110 -men+(tti'cA fi7Pi) Telephone No. (business) Telephone No.(cell) e-mail address Se CV()_' 7 • roil SECTION 11:WORKERS'COMPENSATION INSURANCE AFFIDAVIT 0M.G.L.c.152.§25C(6)) A Workers'Compensation Insurance Affidavit from the MA Department of Industrial Accidents must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the/issuance of the building permit. Is a signed Affidavit submitted with this application? Yes No ❑ SECTION 12:CONSTRUCTION COSTS AND PERMIT FEE Item Estimated Costs:(Labor and Materials) Total Construction Cost(from Item 6)=$ 13 i 5(sel.' • 1.Building $ Building Permit Fee=Total Construction Cost x (Insert here 2.Electrical $ 13 , 5 Leg,LI I appropriate municipal factor)_$ 9. g(o.,CO 3.Plumbing $ 4.Mechanical (HVAC) $ Note:Minimum fee=$ (contact municipality) 5.Mechanical (Other) $ Enclose check payable to 6.Total Cost $ 15 t S 1Dq•9 I (contact municipality)and write check number here VD I, L 1 SECTION 13:SIGNATURE OF BUILDING PERMIT APPLICANT By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the bes of my led e and understanding. Siff-r 1, QobeitS A PreS ide t 1-413 _5L17_ V I 2-ZN-z/ PY ,-,ase print and signname Title Telephone No. Date 1p CerL'Cr Si" Lucl l thw rnA- 0 )Ds(v set(►n e-clepctrtmeet+ Street Address City/Town State Zip Email Address Cl{'l2'€V -SeCO(►*1 • ,�• S CtmMunicipal Inspector to fill out this section upon application approval: ;4 •CSA i • / 1 .1 Name i Date c F , , , , , -itizrxt 'rruritt .` rtitic I ' leilifik 1,, fir=.: • 87 Center Street, Ludlow, MA 01056 • Phone: (413) 547 6512 • MA Lic. # 373C E 1 February 24, 2021 i CITY OF NORTHAMPTON 212 Main Street #100 1 Northampton, MA 01060 I ATTN: Building Inspector i RE: Building Permit for 1-23 Eastern Avenue (Eastern Avenue Apartments) i i Dear Building Inspector, Enclosed, please find the following in reference to the above-captioned matter: i 1) APPLICATION FOR BUILDING PERMIT d. 2) CHECK IN THE AMOUNT OF $286.00 t 3) CHAPTER 9 NARRATIVE 0 4) MANUFACTURER SPEC SHEETS N If you have any questions, please do not hesitate to contact this office. Thank you, k/iiattr 8,U641_,Cr- - Robert J. Belanger Operations Manager C � M RJB/kc Enclosure Qitizru • 87 Center Street, Ludlow, MA 01056 • Phone: (413) 547 6512 • MA Lic. # 373C } February 23, 2021 NORTHAMPTON BUILDING DEPARTMENT 212 Main Street, # 100 Northampton, MA 01060 ATTN: Building Inspector RE: Narrative for the upgrade/modification of fire alarm system at 1-23 Eastern Avenue (Eastern Avenue Apartments) Scope of Work: Upgrade/modification of an automatic fire alarm system. Building Description: The structure is a three story building. The building owner is E &J Realty. The building is of wood-frame and masonry construction. The Use Group is R-2 Applicable Laws 780 CMR & Standards: 527 CMR 1.00 NFPA 72 2013 Edition NFPA 70 (2017 National Electrical Code) Design Methodology: The installation of the fire alarm system is prescriptive, design/build based, whereas the designer of the system is also the installer of the system (per M.G.L. c. 112, § 81R). The fire alarm system and Chapter 9 Narrative was designed by Robert Belanger. Design Responsibility: The installation of the system was designed by the installing company, Citizen { Security Corp. Fire Protection Systems to be installed: Upgrade existing F.A.C.P. Each of the apartments we will be replacing existing sounding smoke detectors on each level to sound in the apartment when there is smoke detected in the apartment itself. There will be a heat detector in each apartment to sound the common fire alarm system. We are replacing the bells in each apartment and installing horn strobes in each apartment. The system will be monitored with a fire rated cellular communicator transmitting to our UL/FM Central Station. b Carbon monoxide detectors have been installed by Smoke Detector Solutions in each apartment and common basement areas (not part of the existing fire alarm). The common basement areas we will be replacing existing smoke detectors and outdated pull stations. Testing Criteria: A. All testing will be coordinated by Citizen Security, 87 Center Street, Ludlow MA 01056. Phone number: (413) 547-6512. Contact person: Kristin or Bob. B. Testing methodology will be the use of smoke detector tester (smoke in a can) for each smoke detector, and manual activation of each pull station. If I can be of any further assistance, please do not hesitate to contact me. I am in the office Monday through Friday from 9:00 a.m. to 4:00 p.m. Sincerely, cry k' Robert J. Belanger Operations Manager RJB/kc • :1,1'Amp'a :1101,11.1,1)3g)110,) Jall1()"9 Joia,wisui 'ittiNturlici -c Joiaads-toi irap).341:4-I- 4A,...q„)tii-kol,-0!.)T IttakujAttba tim!ppnli 7 lititJ;i a Jo pull -I ., :( wl 41,14p) (,`ITActliiity JuTssi #4s twart(1IlLUA441 :ii 1.4.431 Jo i;i!,) itt!.,110)wit?,JO 4fip.fq pappi4l0,7 wit ffri'fidin s!iii it!01!1,41 xit(I 'AP",,Ali 1[0.!•giO _ .. .. -2,t Sal - i_ h . 1.1,--)) I2 - 'yti 73.17-1,10.1 pun MU.,V!.,1,11)qpi moi.loid ttopouttolug.11111'nip,Cinf„tod fo 4pro, on\It!oil,ltp_idim,0147,1:0p.t,-711 op 1 nattrunsu!Joi via nip,10 cl-101111,1caNui In"'Al°;1111 01 Papir Nvoj::)q ,c,rtil itiant.-q1.>-,sp41 to Xdoa‘,-,-Jotervi‘ :+11)Isii!ett 4,1r.p r 04Y0c7.S 01 dtlio mlli kl Pi".Inaso NMOM tiOIS via two,'mil u!''."1od PAP cr•Pm ,sr lu-ItuuosPciul! -"17',C "uo J0414117 00-00c Is 01 dn mill r (il niqrqs-nind uogrio!A triliumo r v.!vs-TA -L-ci -.7.1 low lopur Futribco n ZIRRIZPArtZ$.1.111:145 in 3,,mitnA Q°70(0 141UP uo1)im!dx4 puu 44qtuan ik"Zstlii}d 4q)#1.qm(gs)a'ilini uoptuvRap A'zinod twqrst;44141ozo„.5444,1040‘aq)jo (do3 v qam)y. -Y1A1 tirqd 0 ...1,7,,,...s.xli,) ?Nci uy-)-1-s r3 _'1 _I ;s-uppv.vs qof 1 -z-h 1- b :....,..,..,„,,,„dx.,,,, i-,b 1 1-,er) 1 0 rv\ le-3 :L.,. %-yri _ d-r1a-A--4-) -a)Alvxyls-urr .19 A--v71-...--c :,?1,14rN AUCdwoj.,1,Y1.117,311Stli v wog/Phi/Jo:A? opc gni pun.,1',7ipol Oiff s.ii(rpsr -sw,foirdirio A'Ati Jof 41,11/tM111110 t1111111811.1d1047.1.swyJam gropbt1,a4 N.!'mg.1.1,,Copfuto us;lilt,1 ocunr4.A7liott"dtnia,..riilriiiovk 11.11#iliril id Isntra 1,"1/1 Nx*Koldno:,..r9.uartr:Juon-gri.;NI Ji c.1:1,4i.ildunt 70iirlf V49frit: Ivirrl liliii 01 ViThlif*A inrr rill'.,..lefrirlyint."-Crin:ttir jiiii Ptlfell nicri iiinvirlipi volirc rrivirlrrypr In Fiitrieur-mint N-Ni volt 1,,,,,, R ...,.w4 ,„ qp.,„„,,E,,,,,,,,,„..,..„4,,,,3,411.11‹..unmuJuki:,Tiiiinro zinir ii1N)pin ir,litii iris Sump:um ocAtil iiturcnim lt srpgir sqp titiKins otim..4nitiviainliori LtrgiS 5) "Illeirrlitili,J171 d unTmlatinter, v„.4.-evoil,J!..,1,91 Su!Ar,09s N.kniNuorrre4 alp inn[pj(Kip.mai 1.voq sl,p,alp mg rtivaricitin Arne. I / II ril 'i,' I 'V lAjI I K.Annhar...,vmr.zrmut Amtro win sA(NJ'Kl:5,A:rirdun Ott Awit 71-1A PUff'it it 4',I-5E 1 a pro...4 6,4(1 rall,C;Et I , 1 •1 19,1.4 1X1 110nattli:ns:1 10 r9 "irmill ri:Kilsavti"Aril iiiiui:iiirjo cit.r1.111T Ur010.107/10:".11"LW.11,4 n'y clluda,3 ooli 'i'Ailt:r111,111•612,1.-+,,z2.714,0%.1 4,1a1 pt,u7,.,..N.coldut,,,.Nt.9 s4ttrImutico..qm,s,mi 1 j F ;•t:1 laattk polemic NI t10 0n101'5,10311t1X1E1011-4.1M;Up pa,uti a,kell i pur Jalmnuma nAil r nir r E:jc ,:uoq)ppr:h.)FxrdAt-gufguirild ETZ 1 -s,-,:,,,nicItzr,-+nu 1)!,,o-vxotzlairod 1 s 1,30111PF 30'S3!at',13 itl.Z,1^1IN'il Dii 1 .licw Au!Jil.111111Incui utuymuzdturk.-,,c,tay.m%AVON 1X111,11:10ra11110,11111 IRLD 3.1nwon I tilm r -414,,dord?au uct 110,,,,itr.ptipi..40.1 al v.loprAtirgr gmrni N!rot pur LmtAkoor,uent tz um I 't tloiltppU'iitiTilnii D 0 I 1 trompuia El ,i--puld,..,11.7our....11.,,,,gt liti#01,'S.1,,111011.0rsa"Jpviiin Irailyi[in Su!ctp 1.1u.Aik,tunti n te,M .l -6 [-roisIttsql xmir.„..gtvtn•clizio,,v,Amilnks,orsj-CIEloiri,,,:ur iitili;TottLIA D -s .Mil RI ;`,1!1)10 ti. .7,4.74,01,31t1.1 nu 11,4,09 pUtl dttr.01111,041 10 unxidreld No*.r,uir I Eiz 110tP11.315110a MAIN D "L 1 .r.varil•Inld PO par irtilivA,:qatituri— q 1 ifilVe 11i/Idttr:,e.inmijOi •r 4 :(p4,1p1b:),$)pa fi (1 jo art.4 :v041 4104441.4,1dif nil vatt),44.40ioichkii,11/i Filli;2.11," - , l I-1 ') :': sIe".141 (1) -1 I 0 •sslIppv. . -- r --0 ?--14 L') d_II 0 yi..._ likry)?s 1Ace-2_H.\-pa- :Ornpt-oru 1 twiprinreSio,szulsnil t,;Ittir N. IL ttili-0-1 litya ma:aid ii(r!)Eteiitijilt lilElq(1(11V '‘,.11-110111 IN !)',.1-LI 1041i:id 111 I.flu IA(ri'ii i lii (),i -44,1qtAinhic,44111F)!J13:11:11sJilviv,411141 );sAappna :1!NEpury.13nratuoi) tea!),14,11a4,11110 ),S-0,140 tt A. 10Z-t1fr.19 IIt 0 0 1 4-11..plE V..??..1,1S- %cd.,1110 ) I sittapp3I--jrn, porptil„to ittouri,trnba VildS71,1/3/)ccitirit it) ipind,li11011111119,) dill ;_ . ...,.....................J -V, DMP.COM 000000 a DM PA LAPMS MEI iComS1 Series ram. • Adding advanced network communication extends the fife and expands the capabilities of older " SYSTEM FEATURES panels • Provide monitoring station communication over network for • fully supervised network • Tour zones or Bell • Private labeling available any burglary,commercial fire,or fire and burglar alarm Monitoring on the rubber logo insert residential fire panel communication • Wiring for Ademco ECP Bus • Two outputs • Use Contact ID capture,four slave • Program your own account zones,or Bell Monitoring number to easily work • Communicates with • Program Honeywell`VISTA* around locked panels DMP SCS-1R and SCS-VR panel through iCom using • iComSt`"enables basic remote panel Receivers Compass" control via Virtual Keypad"app • Contact ID dialer capture • ArmedVdislmed status LED • Provides end user alerts of arming/ disarming,alarm,and other events iComSL SERIES WORKS WITH MOST PANELS MULTIPLE CONNECTION OPTIONS Specifications If the existing panel supports Contact ID iComSL communicators can be Dimensions 5.5"W■3.75"H•1"D capture or four slave zones,then it's a attached to the existing panel in a Color White or Red(Fire) candidate for upgrading with the iComSL variety of ways.It can capture Contact Open-Collector Outputs 2 or iComSLZ.There are no issues with ID messages from the dialer,or connect Zones 4 lockout codes.Simply add the iComSL the four input zones from outputs on unit to the existing installation and the panel;or it can sense the output Primary Power(i(omSl) 12VDC program in your own account number. of the bell of an existing alarm and Primary Power(COmSlF) 12-24V[X communicate the appropriate message Current Draw AVAILABLE MODELS to the monitoring station. 12 VD(Alarm/Standby 59 r11A The iComSL provides control of basic panel security functions and video.The FOUR ZONES 24 VDC Alan/Standby 33 mA iComSLZ adds the ability to remotely Both of the iComSL models provide four Ordering Information interact with Z-Wave devices,enabling zones for connection to burglary control a variety of home automation features panel outputs.Zone 4 is intended for I(Of11S1. Network Alarm(omrrilN(dlor including control of lights,door locks, connection to the control panel KomStf Network Fire AlarmCommuncalor thermostats,and more. bell output. Certifications FIRE COMMUNICATION EASY UPGRADE FOR DIALER-ONLY PANELS For approval incormatian,access DMP.com The iComSLF offers network fire Older,dial-up panels have new life with and select Compliance. communication on any fire control panel the addition of network communication. via Contact ID captures or zone inputs. Earn customer loyalty by extending the Meets NFPA 72 standard for single life of their existing panels,enabling communication technology. them to increase the ROI on their system investment and build satisfaction MOBILE SYSTEM CONTROL with the purchase decision. With iComSL communicators,you can easily update your older residential BUILD CUSTOMER LOYALTY and commercial customers to the Avoid the possibility of customers latest network communication links. seeking mobile intrusion alarm features With network in place,end users can from a competitor by enabling those remotely access their panels via the features on their existing panel with a Virtual Keypad"app.This makes it minimal additional cost.They are less possible to use their mobile devices likely to switch systems and cancel their not only to control basic arm/disarm contract.When the time does come to functions but also to receive alerts. replace the panel,they are more likely to rely on you. ENABLE VIDEO ON THE APP The app can be branded with your Video is no longer an expensive option. With the iComSL communicators,you organization's logo and contact can easily add wireless cameras.Via information to provide a daily reminder the Virtual Keypad app,end users can of your services. remotely see their premises to confirm OUTPUTS an alarm or simply check in on children, Use outputs to connect to an arming senior adults,or pets.Users can also zone of an existing panel for control of capture still or video images. that panel via the app. FULLY SUPERVISED COMMUNICATION UPGRADING HONEYWELL VISTA PANELS 800-641-4282 I DMP.com Provides a fully supervised alarm The iCom modules can be programmed 2500 N.Partnership Blvd,Springfield,MO 65803 communication path for burglary Designed,engineered&manufactured in to easily takeover Honeywell VISTA Springfield.MO using U.S.&global components control panels and fire control panels over the network connection providing panels.The communicator can connect to a VISTA series ECP bus,which will allow IIMIIFD WARRANTY:DMP warrants that the higher speeds.iComSL allows alarm you to program the Honeywell panel products manufactured by DMP and described messages to be communicated to an remotely using Compass. herein shall be free from defects of manufacture, SCS-1R or SCS-VR Receiver. labeling,and packaging for a period of three (3)years from the invoice date to the original LOCAL UPDATES Buyer,provided that representative samples The Model 400 USB Flash Module of the defective products are returned to DMP allows you to easily field update for inspection...To read the full DMP limited firmware for panels that would Warranty,go to DMP.com/Warranty or check the otherwise require the use of a computer DMP Pike List or tatabg. and a Model 399 Programming Harness. 2019DiptalNoritoringProduds,Inc 111.14I2119372 DMP.COM a, DMPALARMS • „„: ... XR15OFC/XRSSOFCFA(P so us tar so in via se f IMODc3!t FEATURES • Up to 562 two-wire smoke ► Eight communication paths • Built-in 32-character LED ► Powerful addressable fire alarm detector or fire initiating between the panel and annunciator on panel door control panel(FACP) zones on XR5501C central station ► Output groups deliver • Proven reliability suitable for Up to 142 two-wire smoke ► Built-in remote or maximum functionality commercial and industrial detector or fire initiating on-site firmware with easy programming installations zones on XR150K upgrade capability Onboard Network ► Full range of zone expansion, ► Up to.5 Amps 12 VDC ► 12,000 event buffer ' Onboard 10/100 communication and relay smoke and auxiliary output autosensing Ethernet or output capability with OVC protection ' French,Spanish and English Wi-Fi connection menus available ► Flash updatable—locally over ► Up to 1 Amps 12 VDC ' Customizable check-in time cell or network supervised bell output ' Multiple onboard status LEDs and retry time ► Onboard digital dialer,network ► Up to 506 fully ' Up to 100 output schedules ► Suitable for multi-site communicator or optional programmable Form C relays to control relays and panel applications cellular communicator outputs ► Serial 3 Digital Dialer or CID reporting to mritipie receivers • 32 individual reporting areas with common areas -NIDMP.COM ) aDMPALARMS D XR150FC AND XR550FC FIRE PANELS NETWORK OR CELLULAR COMMUNICATION ZONE EXPANSION The XR150DFC and XR5SODFC provide Built-in 10/100 auto-sensing Ethernet The XR150FC and XR550FC provide up to basic fire monitoring for any single connection enhances both standard and 574 zones,programmable for a variety of site application.The XR150DNFC and encrypted line security options.Both fire applications.The system provides Class XR55ODNFC panels provide all the same UDP and TCP are supported.The network B 12 VDC powered zones,two on board basic fire monitoring as the XR150DFC option can be used as the primary or and four on the 715 Module,plus eight and XR550DFC,enhanced by the onboard backup path to the digital dialer or cellular panel burglary zones.Up to 64 zones are Ethernet connection that allows the use of option. available on 16 keypad addresses,and up Network Monitoring''.Both panels come to 100 zones are available on each built-in The XR150FC and XR55OFC Series panels fully assembled from the factory with the may be used with the 263 Series Cellular LX-Bus"using expansion modules. following components: Communicators as the primary path(no FIRE VERIFY Control Panel backup required)for commercial fire This is used primarily for smoke detector The XR150FC and XR550FC Series installations. circuits to verify the existence of an actual addressable fire panels provide The check-in and fail time settings are fire condition.When a Fire Verify zone complete system control for local NAC programmed for five minutes.As the initiates an alarm,the panel performs a operation.Additionally,DACT,NET or Cell backup path,the 263 communicator Sensor Reset.If any Fire Verify zone initiates communication to the monitoring center provides the security of a communication an alarm within 120 seconds after the reset, are provided.The microprocessor-based link that continues to function,even when an alarm is indicated.If an alarm is initiated panel also provides input for Class A zone landlines are cut or compromised.The after another 120 seconds,the cycle is expansion,conventional and addressable communicators can be used as a stand- repeated. smoke detectors,pull stations and alone communicator without the need heat detectors. for a backup.This interface works over a NOTIFICATION CIRCUIT EXPANSION Keypad Annunciator variety of carriers in the USA and Canada. Easily add NAC outputs to the XR150FC/ The Fire Command Center mounted in the XR550FC system.Up to three Class B door offers a 32-character full text LCD EIGHT COMMUNICATION PATHS modules can be mounted within the FACP. readout that displays system events and Configure up to eight communication Model 865 or 866 Class B NAC Modules menu prompts,making it efficient and paths between the panel and central may be combined with a power supply to easy to use. station. Each path has its own panel provide additional 4 Amp NAC outputs. communication programming parameters Use an 867 on the SLC Loop to further Transformer and Enclosure and can be identified as either primary expand NAC circuits. The 16 VAC,56 VA wire-in transformer is or backup.This enables installers to factory installed and features a built-in PTC configure a reliable communication link, FIRE DRILL AND ONE-MAN WALK TEST for power circuit protection. offering greater confidence that the Users can test fire notification bells using panel will always be connected to the the Fire Drill feature.A special code is also FLEXIBLE COMMUNICATION central station. available for installers to test the system. The XR150/XR550 Series of commercial The One-Man Walk test allows a single fire panels has transitioned from dialer- COMMUNICATION FUNCTION DIAGNOSTICS technician to check the panel response to focused communications to a true The enhanced diagnostic menu enables fire,burglary,panic and supervisory zones. network and cellular communications technicians to check network and cellular approach by providing stronger,multi- communication status,cell signal strength BUILT-IN PROGRAMMER AND DIAGNOSTICS layered panel communications that and email status from the keypad. No programming device is required, ensure a constant link between the panel enabling installers and service technicians and central station. 12,000 EVENT MEMORY to fully program the system and run Allows the user to view the last 10,000 diagnostics from any DMP LCD keypad. The unique DMP Serial 3 format supports door accesses or 2,000 system events that Check the electrical state of zones,find 16 or 32-character users,zone and area occurred over the past 45 days. individual zone numbers,check the LX-Bus names to decrease the central station response time and limit dependence on FIRE ZONE PROGRAMMING for missing,overlapping and/or extra zones automation literal tables for message and much more,all from any DMP LCD Program zones for fire,fire verify, keypad. conversion. fire retard,presignal,cross zoning,or REMOTE ANNUNCIATOR fire supervisory.This flexibility allows FLASH UPDATABLE the ability to match individual zone The XR150FC and XRSSOFC panels accept Install up to eight 630E Remote characteristics to the needs of any area in software updates using Remote Link" Annunciators to meet the requirements of the fire installation. software.This makes it easy to perform the virtually any installation. flash update remotely any time new panel feature updates release. FIRE PANELS . ,-, OUTPUTS REMOTE LINK Commercial Smoke Detectors:The The XR150FC and XR550FC allow the The Remote Link programming software 1164 includes synchronized sounders use of two SPOT relay outputs and four takes advantage of the easy-to-use and a tamper switch.The 1164NS is open collector outputs,which may be simplicity of Microsoft°Windows'".The for applications with existing sounder/ activated by zone or system events, XR150FC and XR550FC panels include notification devices. by schedule,through the User Menu an interface connection for installers to 1183 Wireless Heat Detector:The 1183 or when a card is presented. Output use to connect a laptop computer. Series is a reliable,ceiling-mount heat Groups allow multiple outputs to sensor available in two versions.The activate with a single event and/or can COMMERCIAL WIRELESS FIRE DEVICES 1183-135F responds if the temperature be assigned to a particular user profile. The list of DMP wireless devices that exceeds 135°.The 1183-135R adds a have earned the UL Commercial Fire rate-of-rise feature that responds if OUTPUT SCHEDULES Listing include: the temperature increases by 15°F per Achieve maximum system flexibility 1103 Universal Transmitter:Two-input minute or more. with 100 programmable schedules that transmitter typically used in commercial simplify planning and operations.Control y y 1184 Carbon Monoxide Detector: burglary door or window applications. The 1184 Carbon Monoxide Detector any contact-activated device with schedules that automatically regulate 110OR Wireless Repeater:Extends the is the ideal choice for difficult-to- relays and switched-ground outputs. communication range of DMP receivers, wire locations,applications where enabling physically larger,more reliable room aesthetics are critical or where STATUS LIST wireless security systems. hazardous materials are present. To provide maximum system flexibility, 1100X Wireless Receiver:The The sensor provides an early alert of fire zones may be programmed to 1100X Receiver supportspotentially up to 500 harmful levels of carbon display at a specific keypad.In this transmitters and satisfies all wireless monoxide in residential or commercial manner,all fire zones can be monitored applications. installations.In addition,it also transmits in one location,and other zones can trouble,tamper and low-battery 1100XH High Power Wireless Receiver: be programmed to display and be messages to the panel. monitored at different keypad locations. Provides additional transmit and receive amplification for improved performance at greater distance or in harsh building environments. j 4 ;, 1183-135R 1103-W 1164-W Wireless Rate of Rise Universal Transmitter Commercial Listed Smoke Detector '' Heat Detector . 4` r F:E with Sychronised Sounder r orn ''1otnr Hell- ne 1 I .. ,`. .ra : . 1 1 1103-W 850S ; •• / Universal Transmitter Manual Fire Alarm ,r:;,, ,c;n;rt,;f:c Pull Station 1184-W Wireless Carbon - - °• "" Monoxide Detector Sync Module Sync Module 1100R-W 1100XH-W I 1 i a li _. L2,1,.., ter.. . . , . . „ :t::: 865 866 867 :'.. �� 630E Remote Annunicator Power Supply X R 5 5 0 D N FC 711 715-8 or 715-16 Zone Expansion Module Zone Expansion Module FIRE PANELS COMPATIBILITY REFERENCE SHEET :: ,: :::,-- Keypads 306 Tamper Harness System Specifications 630F LCD Remote Fire Command 307-S Screw-On Tamper Switch Primary Power(included): Expansion Modules 3012 Clip-On Tamper Switch 16 VA(56 VA transfomter 710 Bus Splitter/Repeater 335 Intrusion Siren 711 Single Zone Expansion 370 Lightning Suppressor Secondary Power: 714 4-zone Class Expansion 314 Surge Voltage Suppressor 12 VD(Battery 714-8 8-zone Class-B Expansion 381-2 18"Coax Extension Models:365,366,368 or 369 714-16 16-zone Class-B Expansion 431 Output Harness Output Rating: 115 4-zone 2-wire Smoke Expansion 861 Power Distribution Module Bell Up to.1 Amps at 12 VD( 715-8 8-zone 2-wire Smoke Expansion Monitoring Center Receivers Smoke and Auxiliary Up to y Amps at 12 VD( 115-16 16-zone 2-wire Smoke Expansion SCS-1R Network Enabled Receiver 716 Output Expansion,4 Form C compatible with central For installations total bell,smoke,and relays,4 Open Collector Outputs station receivers that accept aubllarycamotexrc d 1.2Maps using a56 111 Graphic Annunciator.20 Open Standard(ID,DD or DMP Serial 3 VA transformer Collector Outputs messaging Current Draw: Cellular Communicators SCS-VR Virtual Receiver 180 mA 263HCAN HSPA+Cellular Communicator Software only solution that runs Canada on a server for network IP and Enclosure: 2631TE-V LTE Communicator for Verizon cellular communications Material (old rolled steel(Red) 263LTE-A LTE AT&T(New) DMP Wireless Ordering Information Auxiliary Modules 1100X Receiver XR150DK-R XRl5OFireControlPanel 860 Relay Output Module 1100XH High-Power Receiver XR150DNK-R XR5O Fire Control Panel with 865 Style W/X Notification Circuit 1100R Repeater Network Module 1103 Universal Transmitter,External XRS50Df(-R XR550 Fire Control Panel 866 Style W Notification Circuit Contact XR550DNK-R XR550 fire Control Panel with Module 1164 Wireless Smoke Detector with Network 867 DX-Bus Notification Circuit Module Synchronized Sounder Certifications 869 Style D(lass A Initiating Circuit 1164NS-W Wireless Smoke Detector with California State Fire Marshal((SFM) Module No Sounder New York FDNY 893A Dual Phone Line Module 1168 Wireless Smoke/(0/low Temp Refer to the XR150FUXR550K Compliance Detector Power Supplies fi 1183135E Heat Detector Guide(11-1330)and specic compliance 505-12/IX 5 Amps @ 12 VD( listings for installation and programming 50512E 5 Amps @ 12 VDC 1183-135R Heat Detector requirements necessary to meet a particular 505-12A 5 Amps @ 12 VD( 1184 Carbon Monoxide Detector approval. Pull Stations Computer Software 850 Series Pull Stations Remote Link'"Programming Software FCC Part 68 Dealer Admin'" K(Part 15 Smoke/Heat Detectors Underwriters Laboratories(UL)Listed 2W-BLX Conventional Smoke ANSI/U1864 fire Protective Signaling 2Wf-BD( Conventional Smoke/Heat Accessories For additional information, 270 Network Transient Suppressor go to DMP.corn/Compliance. 277 Commercial Fire Buzzer Module 300 Four-wire Harness 303 Silence/Reset Push Button 305 Plug-in Output Relay 800-641.4282 1 DMP.com 2500 N.Partnership Blvd,Springfield,MO 65803 Designed,engineered&manufactured in Springfield,MO using US.&global components •2019 Digital Monitoring Products.Inc. 1 tT-1311I19313 Edwards® 280B-PL Series Rate-of-Rise and Fixed Temperature Heat Detectors „, OD MDwr 1"a1NT Features • Low profile with wide base • Positive fixed temperature rrr . operating indication •On site testing of rate-of-rise feature Description The 280E-PL Series heat detectors offer fixed temperature or combina- tion rate-of-rise and fixed tempera *NOTE: Maximum detector coverage WARNING:This device does not pro- ture features.The heat detector is has been determined by UL to pro- tect life against fire and smoke. In available with a white plastic revers- ible mounting plate.The plastic plate vide detection time equal to sprinkler most fires, hazardous levels of can be used for either flush or sur- devices spaced at 10 ft(3.05m) inter- smoke,heat and toxic gases can build face mounting.It includes a white vals on a smooth ceiling 15 feet 9 up before a heat detector would ini- skirt which covers the space between inches(4.8m)high. Higher ceilings tiate an alarm.Independent studies detector base and the mounting sur may adversely affect detection time. indicate that heat detectors should face. Earlier detection may be obtained by only be used when property protec- reducing the spacing between detec- tion alone is involved.In cases where Agency Approvals tors. (See NFPA 72,Chapter 5) life safety is a factor,the use of •UL Listed Installation smoke detectors is recommended. •FM Approved The intended use of the Edwards Twists and locks onto mounting plate. 280B-PL Series Heat Detector is to •CSFM Listed Mounting plate may be surface provide one source of information mounted or mounted onto any 3 1/4" that is supplemental to smoke detec- Specifications (83mm)or 4" (102mm)octagon box. tion to increase the probability that •Single circuit normally open contact Applications an early warning will be provided so -, az rated at 3 amps at 6 to 125V AC; that property can be safeguarded. 1 x. 1.0 amps at 6 to 28V DC,0.3 amps Consult NFPA 72, National Fire Alarm Heat detectors do not always detect ,, y at 125V DC, and .01 amps at 250V Code, for complete application fires because the fire may be a slow 3 ?' DC guidelines. smoldering,low heat type(produc- •Maximum coverage 2,500 sq.ft. o (232.25 sq. m)* N •UL spacing: 50 ft(15.24m) UL Max. •FM spacing:30 ft(9.14m) Ambient D •Maximum distance from wall or Rate-of-Rise UL Temp. Ceiling Temp. og ceiling projection extending down Cat.No. Description Rating Rating°F Rating°F a more than 12" (305mm)-25 ft 281B-PL ROR&Fixed 15°F/min. 135 100 = (7.62m) 282E-PL ROR&Fixed self-restoring 194 150 D . •Color white N 283E-PL Fixed — 135 100 a s See System Design Criteria on page a" 12-46 284E-PL Fixed — 194 150 D 1999 EDWARDS CMIA HESHIRE, +1f Z�'? HESHIRE, CT 06410 ! L x www.edwards-signals.com SIGNALING PRODUCTS Fax-on-Demand # 1259 •a SYSTEM \,.. SENSOR' . _A Selectable Output p w 1. Horns, Strobes, and - . 1 Horn/Strobes W ii i 1 SpectrAlert"Advance selectable-output horns,strobes, 1 : , } and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTF Iert tarartarA NI C q The SpectrAlert Advance series of notification appliances is Features designed to simplify installations,with features such as plug in •Electrically compatible with existing SpectrAlert products designs,instant feedback messages to ensure correct installation of individual devices,and 11 field-selectable candela settings for wall 'Automatic selection of 12 or 24-volt operation at 15 and 15/75 and ceiling strobes and horn/strobes. candela •Plug-in design When installing Advance products,first attach a universal mounting •Field selectable candela settings on wall and ceiling units:15,15/75, plate to a four-inch square,four-inch octagon or double-gang 30,75,95,110,115,135,150,177,185 junction box.The two-wire mounting plate attaches to a single-gang .Same mounting plate for wall-and ceiling-mount units junction box. •Shorting spring on mounting plate for continuity check before Next,connect the notification appliance circuit wiring to the SEMS installation terminals on the mounting plate. •Tamper resistant construction •Outdoor wall and ceiling products rated from—40°F to 151°F Finally,attach the horn,strobe or horn/strobe to the mounting plate •Design allows minimal intrusion into the back box by inserting the product's tabs in the mounting plate's grooves.The •Horn rated at 88+dbA at 16 volts device will rotate into position,locking the product's pins into the mounting plate's terminals.The device will temporarily hold in place Rotary switch for horn tone and three volume selections with a catch until it is secured with a captured mounting screw. •Outdoor products UI..listed to UL 1638(strobe)and UL 464(horn) outdoor requirements The SpectrAlert Advance series includes outdoor notification •Outdoor products rainproof per UL 50(NEMA 3R) appliances.Outdoor strobes and horn/strobes(two wire and four wire)are available for wall or ceiling.Outdoor horns are available for •Compatible with MDL sync module wall only.All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. Agency Listings .__....._.. SIGNALING MEA ?7131A25-166533ISSS 45lhcord lroNu srms u LISTED APPROVED approvedrill :135-1653989oRhl. MEA452-05-E 53593 'x: 1•1116ltil: ' ... SpectrAlert Advance Sp eciificetions General SpectrAlert Advance horns,strobes and horn/strobes shall mount to a standard 4 x 4 x 1 1-inch back box,4-inch octagon back box or double-gang back • box.Two-wire products shall also mount to a single-gang 2 x 4 x 1' -shop back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync•Circuit`Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync-Circuit Module,12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 Volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified,unfiltered power supply.Strobes and horn/strobes shall have field-selectable candela settings including 15,15/75,30, 75,95,110,115,135,150,177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(continuous) pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate on a coded or non-coded power supply Outdoor Products SpectrAlert Advance outdoor horns,strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit.The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit • entries. • Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn/strobe models over a single pair of wires.The module shall mount to a 4'!/,r,x 411/r6 x 21/4-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z (class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) K Series Operating Temperature -40°F to 151°F(-40°C to 66°C) Humidity Range 10 to 93%non-condensing(indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR' Operating Voltage Range2 8 to 17.5 V(12V nominal)or 16 to 33 V(24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Wall mount dimensions(including lens) 5.6"L x 4.7'W x 2.5D(142 mm L x 119 rnrn W x 64 mm 1/ Horn dimensions 5.61 x 4.7'W x 1.3"D(142 mm L x 119 mm W x 33 mm DI Wall-mount back box skirt dimensions(BBS-2,BBSW-2) 5.91.x 5.0 W x 2.2"D(151 rnrn l..x 128 mrn W x 56 rnrn D) Ceiling-mount back box skirt dimensions(BBSC-2,BBSCW-2) 7.1"diameter x 2.25'high(180 mm diameter x 57 mm high) Wall-mount weatherproof back box dimensions(SA-WBB) 5.71 x 5.1'W x 2.0"D(145 mm L x 130 mm W x 51 mm DI Ceiling-mount weatherproof back box dimensions(SA-WBBC) 7.1"diameter x 2.0"high(180 mm diameter x 51 mm high) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A.05.0395.003 UL Current Draw Data UL Max.Strobe Current Draw(mA 3., R 3� ; r1 r' 8-17.s I.,t< «_1 7.5 Volts 16-33 Volts Candela DC FWR DC Sound Pattern dB DC FWR DC FWR Standard 15* 123 128 66 /1 Temporal High 5/ 55 69 Candela Range ;5,75:, 142 148 / 81 temporal Medium 44 49 58 30" NA NA 94 9ti Temporal Low 38 44 44 75' NA NA 158 153 Non-temporal High 5/ 56 69 95" NA NA 181 176 Non-temporal Medium 42 50 60 110 NA NA 202 195 Non-temporal Low 41 44 50 115 NA NA 210 205 Coded High 57 55 69 High 135 NA NA 278 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Lcvv 40 46 52 50 177 NA NA 281 251 8`_, NA NA 280 _0S ULMax.Current Draw(mA RMS),2-wire HorntStr' tans. to Range(15-11 ' .... 8-175 Volts 16-33 Volts DC input 15 15/75 15 15/75 30 75 95 110 115 Tert ;orai High 137 147 79 90 107 176 194 21 2 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 20/ 216 Non-temporal low 131 144 68 79 96 156 182 201 210 FWR Input Tern ocraI High 136 155 88 97 112 168 190 710 218 Temporal Medium 129 152 78 88 103 '60 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 15S 85 95 110 166 189 208 216 Non-temporal Low 132 15' Sr E1C, 105 6 184 202 211 UL Max.Current Draw(mA RMS},2-wire Ho -*', e 1 ' 16-33 Volts 16-:33 Vnits DC Input 135 150 177 185 FWR input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temporal Low 2.38 254 291 295 Non-temporal Low 214 229 256 2(2 Candela Derating Horn Tones and Sound Output Data ror K ser.es product;used at low temperatures,listed candela Horn and Horn/S ' ratings must e roc weld in accordance with this table. �` ' 3 17.5 16-33 24 Volt Nominal StrobeOut "{ttl} Switch Volts Volts Reverberant Anechoic Listed Candela Candela rating at-40°F Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 32`F 2 Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low 71 73 76 76 83 80 94 89 75 444 Non-temporal High 82 82 88 88 93 92 100 100 95 70 5 Non-temporal Medium 78 78 85 85 90 90 98 98 110 110 6 Non-temporal Low 75 75 81 81 88 84 96 92 115 115 71 Coded High 82 82 88 88 93 92 101 101 135 135 81 Coded Medium 78 78 85 85 90 90 97 98 ISO 150 9r Coded Low 75 75 81 81 88 85 96 92 177 177 'Settings 7,8,and 9 are not available on 2-wire horn/strobe. 185 185 ASS-0355-003 SpectrAlert Advance Dimensions 7-4.7- 2.5=•• 6.8- —_ Dia. fais ill r = _� AO F, al Q1 11.1 __ ._.,_ __ __. ...„.___,....„,„... ..,:. ____ , ..._,_ ..,_77::........ Wall-mount horn/strobes Ceiling-mount horn/strobes h 7.1" z.25 7ia 2.0" D`ia. • 5.05"� i•-2.23� /' '� Dia � 'li _ — _i I \000' • \ r ,` � 0 2.0'Io. .o , ( i c � :,/ r� / 5.98". Rim ( o 5.7" o 010 O \ \ I r \ Q'Aillii Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn/Strobes Ceiling Horn/Strobes(cont'd,) P2R*' 2-wire Horn/Strobe,Standard Cdt.Red PC21A," 2-wire Horn/Strobe,Standard cd,White P2RH* 2-wire Horn/Strobe,High cd,Red PC2WH" 2-wire Horn/Strobe,High cd,White P2RK* 2-wire Horn/Strobe,Standard cd,Red,Outdoor PC4R 4-wire Horn/Strobe,Standard cd,Red P2RHK* 2-wire Horn/Strobe,High cd,Red,Outdoor PC4RH 4-wire Horn/Strobe,High cd,Red P21Ar" 2-wire Horn/Strobe,Standard cd,White PC4RK 4-wire Horn/Strobe,Standard cd,Red,Outdoor P2WH* 2-wire Hom/Strobe,High ccl,White PC4RHK 4-wire Horn/Strobe,High cd.Red,Outdoor P4R* 4-wire Horn/Strobe,Standard cd,Red PC4W 4-wire Horn/Strobe,Standard cd,White P4RH* 4-wire I corn/Strobe,High cd,Red PC4WH 4-wire Horn/Strobe,High cd,White P4Rt\ 4-wire Horn/Strobe,Standard cd,Red,Outdoor Ceiling Strobes P4RHK 4-wire Horn/Strobe,High cd,Red,Outdoor SCR' Strobe,Standard cd,Red P41,11' 4-wire Horn/Strobe,Standard Cd,White S`R I* Strobe,High cd,Red P4'WH 4-wire Horn/Strobe,High cd,White SCRK Strobe,Standard cd,Red,Outdoor Wall Strobes SCRHK Strobe,High cd,Red,Outdoor SR" Strobe.Standard cd,Red SCW" Strobe,Standard cd,White SRH*' Strobe,High cd,Red SCWH*' Strobe,High cd,White SRK Strobe,Standard cd,Red,Outdoor Horns SRHK Strobe,High cd,Red,Outdoor HR Horn,Red SW" Strobe,Standard cd,White HRK Horn,Red,Outdoor SWH* Strobe,High cd,White HW Horn,White Ceiling Horn/Strobes Accessories PC2R* 2-wire Horn/Strobe,Standard cd,Red BBS-2 Back Box Skirt,Wall,Red PC2RH* 2-wire Horn/Strobe.High cd,Red BBSW-2 Back Box Skirt,Well,White PC2RK 2-wire Horn/Strobe,Standard cd,Red,Outdoor BBSC-2 Back Box Skirt,Ceiling,Red PC2RHK 2-wire Horn/Strobe,High cd,Red,Outdoor BBSCW-2 Back Box Skirt,Ceiling,White Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2R-P t Add"-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SP "Standard cd,"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd;refers to strobes that include 135,150,177,and 185 candela settings. All outdoor units/er ending in uK"include a weatherproof back box. �ti\ SYSTEM *2i System Sena. i SENSOR' 3825 Ohio Avenue• •t Charles,IL 60177-649 r:w�kierii mw�x�si�mat.<har. wnhelaWhout rice.Vnasfthis a.six...to ,erx r*,xi�.:n innvma[a+,Lw4x;n..�the I�tes,�a*skn ur,h;s,inia Ax4�. Phone:800-SENSOR2•Fax:630 377-6495 Ac5-0395-003•17N:6•#1676 -..et s _)P Photoelectric Smoke Detectors 3� a System Sensor's 13"'series smoke detectors represent significant advancement in conventional detection. The i3 family is founded on three principles:installation ease,intelligence,and instant inspection. Features Installation ease.The 13line redefines installation ease with its Plug-in detector line,mounting base included plug-in design.This allows an installer to pre-wire the bases included • with the heads.The large wire entry port and in-line terminals •Large wire entry port provide ample room for neatly routing the wiring inside the base. •In-line terminals with SEMS screws The base accommodates a variety of back box mounting methods, •Mounts to octagonal and single-gang backboxes,4-square as well as direct mounting with drywall anchors.To complete the backboxes,or direct to ceiling installation,i3 heads plug in to the base with a simple Stop-Drop, N Lock"action. •Stop-Drop'N Lock attachment to base •Removable detector cover and chamber Intelligence.i3 detectors offer a number of intelligent features Built-in remote maintenance signaling to simplify testing and maintenance.Drift compensation and • smoothing algorithms are standard with the i3 line to minimize •Drift compensation and smoothing algorithms nuisance alarms.Two-wire i3 detectors needing cleaning can •Simplified sensitivity measurement generate a remote maintenance signal,when connected to the •Wide angle,dual color LED indication 2W-MOD2 loop test/maintenance module,or to a panel equipped with the i3 protocol.This signal is indicated by LEDs located at the •Loop testing via EZ Walk feature module and the panel.The SENS-RDR,a wireless device,displays the •Built-in test switch sensitivityof i3 detectors in terms of percent per-foot-obscuration. Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition:normal standby,out-of-sensitivity,alarm,or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol,the EZ Walk loop test feature is available on two-wire 13 detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings ® MEA MSFM LISTED APPROVED 1 1 approved approved +91'. 3011446 7272-1209:210 290-01-E 2O'3 iy Smoke Detector Specifications Architectural/Engineering Specifications S:nc:kc detector shall Lc a;yster ..r, 1'Toties model ... •>>. ..-.l .. .,.c r writers Laboratories LII_ for n...__.„ ara ily Systems. detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 135"F (57.2°C).The detector shall include a mounting base for mounting to 3Y.-inch and 4-inch octagonal,single gang,and 4-inch square hack boxes with a plaster . ring.or direct mount to the ceiling using drywall anchors.Wiring connc.u;a is;hall be made by means of SEA-1S screws.The detector shall allo;•v pre=•.vn:rg of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual color LED indication which blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4W T-B)conditions.When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel,and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.5V Maximum:35V Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 pA maximum average;4-wire:50 pA maximum average Maximum Alarm Current 2-wire:130 mAt limited by control panel;4-wire:20 mA @12V,23mA @ 24V Peak Standby Current 2-wire:100 pA;4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30V AC/DC Physical.Specifications Dimensions(including base) 5.3 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 6.3 oz.(178 grams) Operating Temperature Range 2W-B and 4W-B:3r F-120'F(0':.-49°C);2WT-B and 4WT-B:32"F-100"F(0"C-37.8°C) Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor I 35" (57.2'C)fixed Freeze Trouble 2WT-B and 4WT-B only:41`F(5'C) • Sensitivity 2.5%/ft.nominal Input Terminals 14-22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every':0 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Wiring Alarm Current 2W-B 2-wire 130 mA max.limited by control panel 2V✓T-B Yes 2-wire 130 mA max.limited by control panel 4W-B No 4-wire 20 mA @ 12V,23mA @ 24V 4WT-B Yes 4-wire 20 mA @ 12V,23mA @ 24V Accessories 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacernent tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 in.(16.76cm)diameter SYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 Wu; xdrKm an Srtc:.�sers�. /� /� inform..., sobjectto<Nowv.ithcwtr e.;nrtsys:muinnorcmi SENSOR Phone:800-SENSOR2•Fax:630-377-6495 `°`r'"'P°"'uctin "'.'n"`" the l'stvets,.°`0itdat'se.. AO-05184:k•7/06•K 1676 C) 1 � LISTED ° ""`" '' LI ? , y Ski . c,H 4" PUSH uA i . ., ,v 1 w The 850 Series Fire Alarm Pull stations offer —.-„ ,.,,, rem quick and simple operation that's economical .�. .., 4, ,' and reliable. • Available in single or dual-action manual - pulls • SPST contacts and terminal strip connections • Gold-plated contacts to avoid the risk of corrosion 8505 . J • Approvals: UL and CSFM • Mounts on standard single-gang box • Americans with Disabilities Act (ADA)compliant • Optional surface and weatherproof backboxes available • Die-cast metal construction • High-gloss red enamel finish • Reset key • Scored acrylic breakrod g i %'� �31a�z�.a�w� vm A fJ�v<'€�a`3�x u�W" \fit Z� s ,w ..au`x'6i.' 00eSretW T Ui f a n*0._; emERATt0e4 The DMP 850 Series Fire Alarm Pull A variety of mounting options are On the Model 850D Dual Action Pull Station is a high quality, die-cast available for the 850 series. It can be Station, the push bar rotates inward metal manual pull station available flush mounted to a standard single gang allowing the PULL handle to be grasped in either single-action or dual-action switch box or surface mounted in two in a one handed motion. configurations with SPST contacts and optional configurations. The Model terminal strip connections.The normally 850-SB Interior Surface Backbox or the AferWee5AISIF 70/4F open contact,which closes when the pull Model 850-WP Weatherproof Backbox To create an addressable reporting zone station is activated, is rated for 1 Amp® both allow conduit connection to the for the 850 Series, install a Model 711 30 VDC.The contacts are gold-plated to 850 Series Pull Stations. Zone Expansion module. avoid corrosion risks. » 7ol, Scored acrylic breakrods are used with the 850 series. The Model 8505 Single Action Pull Station is operated by pulling the handle on the front of the station as far down as it The 850 series has been tested by UL for goes. When the handle locks into place compliance to the latest requirements it is easily visible from up to 50 feet. of the ADA. Reset the handle by opening the station with the supplied key,placing the handle in the normal upright position and re-locking the station. Screw Terminals To next To Fire Alarm ii device or Control Panel EOL resistor Model 850 Wiring Diagram M6 Switch Rating 1 Amp®30 VDC 850S Single-action putt station B Dimensions 4.75"li x 3.25"W x 2.25"D 850D Dual-action pull station Color Red w/raised white letters,white 850-SB Interior surface sheetmetal backbox PULL handle w/raised red letters 850-WP Weatherproof surface die-cast backbox f 850 AR Scored acrylic breakrods(1 dozen) The 850 Series Fire Pull Station is compatible with all 850S/711 Single-action pull station w/addressable module ^ - DMP Command Processors. 850D/711 Dual-action pull station w/addressable module Note:All models are supplied with one scored acrylic breakrod and one key. l$ = _ @ it 04 inVAf '; F a SUS 9t E.- ... J =ir 2500 North Partnership Boulevard Digital Monico.ng P..ndoct. Springfield, Missouri 65803-8877