CS 2ND FLOOR JOIST CalcCS Structureâ„¢ 2018.9 [Build 16] kmBeamEngine 2018.9.0.1 Materials Database 1572 Keiter54EmersonWay - Level 8 1-27-21 3:47pm 1 of 1 All product names are trademarks of their respective owners Copyright (C) 2018 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Member Data Description: CalcA11 Member Type: Joist Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PSF Deflection Criteria: L/360 live, L/240 total Dead Load: 10 PSF Deck Connection: Glued & Nailed Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Other Start End Dead Start End Category Replacement Uniform (PSF) Top 0' 0.00" 1' 7.75" 10 10 Live Replacement Uniform (PSF) Top 21' 3.00" 28' 7.25" 10 10 Live Replacement Uniform (PSF) Top 1' 7.75" 7' 2.00" 30 10 Live Replacement Uniform (PSF) Top 7' 2.00" 21' 3.00" 30 10 Live Point (PLF) Top 28' 1.50" 0 1 Live Point (PLF) Top 28' 1.50" 1 123 Live Point (PLF) Top 28' 1.50" 376 0 Snow Point (PLF) Top 0' 4.63" 0 1 Live Point (PLF) Top 0' 4.63" -23 0 Snow 1 2 3 11 6 8 17 0 12 28 7 4 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 213# -15# 2 11' 6.500" Wall N/A N/A 3.500" 892# -- 3 28' 7.250" Half-Wall N/A N/A 1.500" 751# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 169#(127plf) -31#(-23plf) 43#(32plf) 2 651#(488plf) 5#(4plf) 241#(181plf) 3 149#(111plf) 497#(373plf) 254#(191plf) Design spans 11' 1.875" 16' 8.125" Product: 11-7/8" AJS 20 16.0" O.C.PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1028.'# 4400.'# 23% 20.71' Even Spans D+L Negative Moment 1267.'# 4400.'# 28% 11.54' Total Load D+L Shear 751.# 1713.# 43% 28.6' Total Load D+S End Reaction 751.# 1397.# 53% 28.6' Total Load D+S Int. Reaction 892.# 2390.# 37% 11.54' Total Load D+L TL Deflection 0.1095" 0.8339" L/999+ 19.88' Even Spans D+L LL Deflection 0.0789" 0.5559" L/999+ 19.88' Even Spans L Control: Max End React. DOLs: Live=100% Snow=115% Roof=125% Wind=160% Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table