Loading...
PHEC-2172 54 Emerson Way code specs Insulation & Air Sealing Slab R-10 at perimeter and under entire floor Foundation Walls R-10 fire-rated foamboard Blockers & Runners R-21 spray foam Exterior Walls R-21 spray foam Flat Ceilings R-60 loose cellulose (16" deep) Attic Slopes R-49 spray foam Windows & Glass Doors U-Factor = .28 Air Barrier & Air Sealing Details Maximum blower door test of 3 ACH50 Must comply with air sealing table R402.4.1.1 in 2015 IECC Mechanical Equipment Heating Equipment 96% AFUE Propane Furnace Cooling Equipment 17.5 SEER Central AC Ducts ALL DUCTS LOCATED WITHIN ENVELOPE Duct Leakage: No more than 4 CFM per 100 CFA Must comply with 2015 IECC R403.3.3 Ventilation System Energy Recovery Ventilator Water Heater .96 Energy Factor Propane On-Demand Lighting & Appliances Lighting 100% LED bulbs Refrigerator Energy Star certified (If provided) Dishwasher Energy Star certified (If provided) Oven/Range Electric or Gas Washer Energy Star certified (If provided) Dryer Energy Star certified (If provided) Projected Rating Results Scenario HERS Index Score All specifications used above, and home built per plans 53 Stretch Code Specifications Project Address 54 Emerson Way, Florence, MA 01062 HERS Rater Rachel Balon