Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PV Plans Stamped - Rogovin Rebecca
CITY NOTES:ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THEMAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILARTO THE SURFACE UPON WHICH THEY ARE MOUNTED.INSTALLATION NOTES:·PV WIRE SHALL BE USED ON DC RUNS FOR UNGROUNDED/TRANSFORMERLESSINVERTERS.·INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMTCONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNT.·DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETYPRIOR TO ANY EXCAVATION TAKING PLACEPV SYSTEM SUMMARY: 9.940 KWMODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION INACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIREDPER SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THEFIELD.SITE LOCATION ANDHOUSE AERIAL VIEWTHIS PROJECT COMPLIES WITH THE FOLLOWING:AS ADOPTED BY CITY OF NORTHAMPTONCONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUMCODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING ASREQUIRED BY FIELD CONDITIONS.PHOTOVOLTAIC SYSTEMSITE LOCATION:HOUSE AERIAL VIEW:SITE LOCATIONMODULE LOCATIONMAIN SERVICE PANEL:EXISTING 125 AMPS MSP WITH 100 AMPS MAINBREAKER ON END FEDINTERCONNECTION:LINE SIDE TAPOCPD RATING:40AMPSUTILITY:NG - NATIONAL GRIDTILT:12°, 30°AZIMUTH:166°, 76°, 256°RESIDENTIAL PHOTOVOLTAIC SYSTEMSYSTEM SIZE (DC):STC: 28 X 355 = 9940W DC:PTC: 28 X 335.5 = 9394W DCSYSTEM SIZE (AC):7600W AC @ 240VMODULES:28 X REC SOLAR: REC355AA BLACKTABLE OF CONTENTSPV-1SITE LOCATION AND HOUSE AERIAL VIEWPV-2SITE PLANPV-2AROOF PLAN WITH MODULES LAYOUTPV-3MOUNTING DETAILSPV-4THREE LINE DIAGRAMPV-5EXISTING SERVICE PANELPV-6NOTES AND EQUIPMENT LISTPV-7LABELSPV-7ASITE PLACARDPV-8OPTIMIZER CHARTPV-9 & 10SAFETY PLANSHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISION"ROGOVIN, REBECCA"18 WINSLOW AVE,NORTHAMPTON, MA 01062(413) 537-37951/5/2021MFSPV-1F070817FREEDOM FOREVER - INDY 3.01 TEMPLATE ELECTRICAL CONTRACTOR NO:HOME IMPROVEMENT CONTRACTOR198080; BUSINESS ELECTRICALCONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTERELECTRICIAN 1136 MRFREEDOM FOREVER MASSACHUSETTSLLC135 ROBERT TREAT PAINE DR., TAUTON, MA 02780Tel: (800) 385-1075------------GREG ALBRIGHTOPTIMIZERS:28 X SOLAR EDGE: P370INVERTER:SOLAR EDGE: SE7600H-USRGM [SI1]ROOF:METAL STANDING SEAMRAFTER/TRUSS SIZE:2X6 RAFTER @ 24" O.C. AND 2X4 TRUSS @ 24" O.C.ATTACHMENT TYPE:S-5!: S-5-S CLAMP WITH UNIRAC SM LIGHT RAIL2015 INTERNATIONAL BUILDING CODE (IBC)W/780CMR2015 INTERNATIONAL RESIDENTIAL CODE (IRC)W/780CMR2018 INTERNATIONAL MECHANICAL CODE (IMC)2018 INTERNATIONAL PLUMBING CODE (IPC)2018 INTERNATIONAL FUEL GAS CODE (IFGC)2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)2015 INTERNATIONAL EXISTING BUILDING CODE (IEBC) W/780CMR2018 INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC)2020 NATIONAL ELECTRICAL CODE (NEC) UMMSPPMINV ACJBSITE PLANSITE PLANSCALE: 1"=20'1SITE PLANWINSLOW AVEPV SYSTEM9.940 kW-DC7.600 kW-ACROOF AREA : 1537.12 SQ FTSHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISION"ROGOVIN, REBECCA"18 WINSLOW AVE,NORTHAMPTON, MA 01062(413) 537-37951/5/2021MFSPV-2F070817FREEDOM FOREVER - INDY 3.01 TEMPLATE ELECTRICAL CONTRACTOR NO:HOME IMPROVEMENT CONTRACTOR198080; BUSINESS ELECTRICALCONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTERELECTRICIAN 1136 MRFREEDOM FOREVER MASSACHUSETTSLLC135 ROBERT TREAT PAINE DR., TAUTON, MA 02780Tel: (800) 385-1075------------GREG ALBRIGHT84'-1"152'-0"84'-1"152'-0"73'-6"21'-9"22'-11"22'-10"(E) MAIN SERVICE PANEL(E) UTILITY METER(N) FUSED AC DISCONNECT SQUARE DD222NRB(N) SOLAREDGE SE7600H-USRGM [SI1]INVERTER WITH RAPID SHUTDOWN(N) JUNCTION BOX(N) SMART PRODUCTION METERDRIVEWAYROOF LINE(N) 28 REC SOLAR: REC355AA BLACKPROPERTY LINE UMMSPPMINV ACJBROOF PLANSCALE: 3/32" = 1'-0"1ROOFPLAN W/MODULESLAYOUTROOF AREA STATEMENTROOFMODULESQTYPITCHAZIMUTHROOF AREAARRAY AREAARRAYCOVERAGE %SYSTEMDISTRIBUTEDWEIGHTATTACHMENTPOINT-LOAD1612°166°292.47 SQ FT112.89 SQ FT34.27%2.29 PSF14.68 LBS21330°76°496.92 SQ FT244.59 SQ FT3730°256°426.69 SQ FT131.70 SQ FT4230°166°160.53 SQ FT37.63 SQ FTLEGEND:OBSTRUCTIONPIPE VENTMODULESCONDUITMSP AC JBFUSED ACDISCONNECTMAIN SERVICEPANELJUNCTIONBOXINVINVERTERPMSMARTPRODUCTIONMETERPV SYSTEM9.940 kW-DC7.600 kW-ACROOF AREA : 1537.12 SQ FTUTILITY METER UM NOTES:1.EMT CONDUIT ATTACHED TOTHE ROOF USING CONDUITMOUNTS2.ATTACHED CLAMPS AT 25%FROM THE EDGE AND 50% FROMTHE CENTER OF THE MODULES3.JUNCTION BOX IS MOUNTED TOTHE RAIL.SHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISION"ROGOVIN, REBECCA"18 WINSLOW AVE,NORTHAMPTON, MA 01062(413) 537-37951/5/2021MFSPV-2AF070817FREEDOM FOREVER - INDY 3.01 TEMPLATE ELECTRICAL CONTRACTOR NO:HOME IMPROVEMENT CONTRACTOR198080; BUSINESS ELECTRICALCONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTERELECTRICIAN 1136 MRFREEDOM FOREVER MASSACHUSETTSLLC135 ROBERT TREAT PAINE DR., TAUTON, MA 02780Tel: (800) 385-1075------------GREG ALBRIGHT(E) MAIN SERVICE PANEL(N) FUSED AC DISCONNECT SQUARE D D222NRB(N) 28 REC SOLAR: REC355AA BLACKROOF LINE(N) SMART PRODUCTION METER(N) JUNCTION BOX(E) UTILITY METER(N) SOLAREDGE SE7600H-USRGM [SI1]INVERTER2"x 6" RAFTERS @ 24" O.C.2"x 6" RAFTERS @ 24" O.C.2"x 6" RAFTERS @ 24" O.C.2"x 4" TRUSS @ 24" O.C. (E) METAL ROOF (BY OTHERS)M8-1.25 STAINLESS STEELHEX FLANGE BOLTS-5-S CLAMP3/8-24 STAINLESS STEEL ROUNDPOINT SETSCREW (316 HEX DRIVE)(E) METAL ROOF (BY OTHERS)S-5-S CLAMP(E) 2X6 RAFTER @ 24" O.C.(E) 2X4 TRUSS @ 24" O.C.UNIRAC SM LIGHT RAILRACKING SYSTEM(N) SOLAR MODULES(E) METAL SEAMS@ 12" O.C.ROOF ATTACHMENT4'MOUNTINGDETAILSATTACHMENT DETAILScale: NTSSOLAR PV ARRAY SECTION VIEWScale: NTSPARTIAL ROOF FRAMING PLANScale: NTSSHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISION"ROGOVIN, REBECCA"18 WINSLOW AVE,NORTHAMPTON, MA 01062(413) 537-37951/5/2021MFSPV-3F070817FREEDOM FOREVER - INDY 3.01 TEMPLATE ELECTRICAL CONTRACTOR NO:HOME IMPROVEMENT CONTRACTOR198080; BUSINESS ELECTRICALCONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTERELECTRICIAN 1136 MRFREEDOM FOREVER MASSACHUSETTSLLC135 ROBERT TREAT PAINE DR., TAUTON, MA 02780Tel: (800) 385-1075------------GREG ALBRIGHT SOLAREDGE P370 POWER OPTIMIZERSJUNCTIONBOXSTRING-12 - #10 AWG, PV WIRE1 - #6 AWG IN FREE AIR OR#8 AWG MUST BE IN EMT CONDUITSTRING-2SOLAREDGE P370POWER OPTIMIZERS2 - #10 AWG,PV WIRE14 REC SOLAR: REC355AA BLACK14 REC SOLAR: REC355AA BLACK4 - #10 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" ORLARGER EMT CONDUITUM(E) 100A / 2P MAINBREAKER(END FED)(E) 125A RATEDMAIN SERVICE PANEL1PH, 120/240V 60HZ(E) UTILITYMETER(N) LINESIDE TAP VIA ULLISTED CONNECTOR3 - #6 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" OR LARGER EMT CONDUIT(N) MILBANK U5929-XL-INSSINGLE PHASE NEMA 3R600V/100A FORM 2S SMARTPRODUCTION METER(N) 60A RATEDFUSEDAC DISCONNECTSQUARE DD222NRB2 - 40 AMP FUSES(N) SOLAREDGESE7600H-USRGM[SI1] INVERTERRAPIDSHUTDOWNSWITCHACDCCONNECT TO EXISTING UFER3 - #8 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" OR LARGER EMT CONDUITTHREE LINEDIAGRAMNOTE:CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASEDON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANTTO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONSBACKFEED FUSE SIZINGMAX. CONTINUOUS OUTPUT 32A @ 240V32.00X1.25=40AMPS40A FUSES - OKCONDUCTOR AMPACITY DE-RATE CALCULATIONEQUIPMENTWIRE LOCATIONCONDUCTORQTY.AWG WIRESIZENEC FACTORSTABLE310.15(B)(16)NEC FACTORSTABLE310.15(B)(2)(a)CONDUCTORAMPACITY@90C ADJ.NEC FACTORSTABLE310.15(B)(3)(a)1ACINVERTERTOSQUARE D D222NRBEXTERIOR WALL38551551.002ACSQUARE D D222NRBTOPRODUCTION METEREXTERIOR WALL36751751.003ACPRODUCTION METERTOPOIEXTERIOR WALL36751751.00PV SYSTEM9.940 kW-DC7.600 kW-ACSHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISION"ROGOVIN, REBECCA"18 WINSLOW AVE,NORTHAMPTON, MA 01062(413) 537-37951/5/2021MFSPV-4F070817FREEDOM FOREVER - INDY 3.01 TEMPLATE ELECTRICAL CONTRACTOR NO:HOME IMPROVEMENT CONTRACTOR198080; BUSINESS ELECTRICALCONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTERELECTRICIAN 1136 MRFREEDOM FOREVER MASSACHUSETTSLLC135 ROBERT TREAT PAINE DR., TAUTON, MA 02780Tel: (800) 385-1075------------GREG ALBRIGHT EXISTING SERVICEPANELSHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISION"ROGOVIN, REBECCA"18 WINSLOW AVE,NORTHAMPTON, MA 01062(413) 537-37951/5/2021MFSPV-5F070817FREEDOM FOREVER - INDY 3.01 TEMPLATE ELECTRICAL CONTRACTOR NO:HOME IMPROVEMENT CONTRACTOR198080; BUSINESS ELECTRICALCONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTERELECTRICIAN 1136 MRFREEDOM FOREVER MASSACHUSETTSLLC135 ROBERT TREAT PAINE DR., TAUTON, MA 02780Tel: (800) 385-1075------------GREG ALBRIGHT NOTES ANDEQUIPMENT LISTMATERIAL LIST1SE7600H-USRGM [SI1]28REC SOLAR:REC355AABLACKOPEN CIRCUIT VOLTAGE (VOC) :MAX. POWER VOLTAGE (VMP) :SHORT CIRCUIT CURRENT (ISC) :MAX. POWER CURRENT (IMP) :PTC RATING :43.6V36.4V10.47A9.77A335.5W2PV FUSES40A / 2P PV FUSE1JUNCTION BOX600VDC NEMA 3R UL LISTED1FUSED ACDISCONNECT SQUARE D D222NRB 60A RATED,240VAC, NEMA 3R, UL LISTED82ATTACHMENTSS-5!: S-5-S CLAMP242.00FTRAILUNIRAC SM LIGHT RAIL28MID CLAMPSUNIRAC SM LIGHT RAILGROUNDING MID CLAMPS32END CLAMPSUNIRAC SM LIGHT RAIL ENDCLAMPSDC MAX SYSTEM VOLTAGE :AC OUTPUT VOLTAGE RANGE :MAX. AC OUTPUT CURRENT :MAX. AC POWER OUPUT :WEIGHTED EFFICIENCY :480V211-240V32A7600W99%GENERAL NOTES :1.(28) REC SOLAR: REC355AA BLACK WIRED AND LISTED TO UL1703 STANDARDS.2.THE SE7600H-USRGM [SI1] INVERTER WITH INTEGRATED DC DISCONNECT AND ARC FAULTPROTECTION. ATTACHED WITH SYSTEM ELECTRICAL SPECIFICATIONS, GROUND FAULT PROTECTION &LISTED TO UL 1741 STANDARDS.3.PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM DCDISCONNECT/INVERTER AS PER 2020 NEC SEC. 250.166(A).4.SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITHREQUIREMENTS OF ART. 690 OF THE 2020 NEC.5.CONDUIT ABOVE ROOF SHALL BE NO LESS THAN 1" FROM TOP OF THE ROOF TO BOTTOM OFRACEWAY. TABLE NEC 310.15(B)(3)(C).6.PHOTOVOLTAIC DC CONDUCTORS ENTERING THE BUILDING SHALL BE INSTALLED IN METALLICRACEWAY AND SHALL BE IDENTIFIED EVERY 10 FEET -- AND WITHIN 1 FOOT ABOVE AND BELOWPENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS, OR BARRIERS -- WITH MINIMUM3/8-INCH-HIGH WHITE LETTERING ON RED BACKGROUND READING: “WARNING: PHOTOVOLTAICPOWER SOURCE."7.SYSTEM GROUNDING ELECTRODE CONDUCTOR FOR PV SYSTEM TO BE SIZED TO MEET THEREQUIREMENTS OF 2020 NEC TABLE 250.66.8.THE EXISTING MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER.9.UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM.10.TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION.11.SOLAREDGE INVERTERS ARE LISTED TO UL 1741 AND UL 1699B STANDARDS.12.SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDS.20 FTCONDUIT3/4" OR LARGER EMT CONDUITSHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISION"ROGOVIN, REBECCA"18 WINSLOW AVE,NORTHAMPTON, MA 01062(413) 537-37951/5/2021MFSPV-6F070817FREEDOM FOREVER - INDY 3.01 TEMPLATE ELECTRICAL CONTRACTOR NO:HOME IMPROVEMENT CONTRACTOR198080; BUSINESS ELECTRICALCONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTERELECTRICIAN 1136 MRFREEDOM FOREVER MASSACHUSETTSLLC135 ROBERT TREAT PAINE DR., TAUTON, MA 02780Tel: (800) 385-1075------------GREG ALBRIGHT28SOLAR EDGEP370 POWEROPTIMIZERSMAX OUTPUT VOLTAGE :MAX OUTPUT CURRENT :RATED INPUT DC POWER :INPUT MAX VOLT @ LOW TEMP :INPUT MAX SC CURRENT (ISC) :MAX DC INPUT CURRENT:60VDC15ADC370W60VDC11ADC13.75ADCQTYEQUIPMENTDESCRIPTION 1.NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGSSHOWN HEREON.2.ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED ORMACHINE PRINTED LETTERS OR ELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINEWORK.C.AERIAL FONT.3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED INTHE LOCATIONS SPECIFIED. SIGNAGE CANNOT BEHAND-WRITTEN.3.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITHPOP-RIVETS OR SCREWS.NOTES:M690.54705.12(B)(2)(3)(b)"WARNING"DUAL POWER SOURCESSECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT - 32 AMPSAC NORMAL OPERATING VOLTAGE - 240 VOLTSWARNING:POWER SOURCE OUTPUTCONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICE.TURN RAPIDSHUTDOWN SWITCH TOTHE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCE SHOCKHAZARD IN THE ARRAY690.56(C)(1)(A)SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNAC 690.15, 690.54PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT - 32.00 AMPSAC NORMAL OPERATING VOLTAGE - 240 VOLTSRAPID SHUTDOWN SWITCH FORSOLAR PV SYSTEM690.56(C)(3)INVERTERARRAYJ/BDC"WARNING"PHOTOVOLTAIC POWER SOURCEEVERY 10' ON CONDUIT AND ENCLOSURES"WARNING"ELECTRICAL SHOCK HAZARD.TERMINALS ON BOTH LINE AND LOAD SIDESMAY BE ENERGIZED IN THE OPEN POSITION690.13 (B)690.53PV SYSTEM DC DISCONNECTMAXIMUM VOLTAGE: 480VMAXIMUM CIRCUIT CURRENT: 32AMAX RATED OUTPUT CURRENT OFTHE CONTROLLER OR DC-TO-DCCONVERTER: 15ANEC 690.31(G)(3) & (4)PMPV METERSOLAR ELECTRICPV PANELSSHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISION"ROGOVIN, REBECCA"18 WINSLOW AVE,NORTHAMPTON, MA 01062(413) 537-37951/5/2021MFSPV-7F070817FREEDOM FOREVER - INDY 3.01 TEMPLATE ELECTRICAL CONTRACTOR NO:HOME IMPROVEMENT CONTRACTOR198080; BUSINESS ELECTRICALCONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTERELECTRICIAN 1136 MRFREEDOM FOREVER MASSACHUSETTSLLC135 ROBERT TREAT PAINE DR., TAUTON, MA 02780Tel: (800) 385-1075------------GREG ALBRIGHTLABELS UMMSPPMINVACJBNOTES:1.NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS SHOWN HEREON.2.ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS ORELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK.C.AERIAL FONT.3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED.SIGNAGE CANNOT BE HAND-WRITTEN.3.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS.MAIN SERVICE PANELINVERTER EQUIPPEDWITH RAPID SHUTDOWNJUNCTION BOX28 PV MODULEWINSLOW AVEAC DISCONNECTLABELSPRODUCTION METERUTILITY METERCAUTION:MULTIPLE SOURCES OF POWER LOCATED AS SHOWN.DANGEROUS VOLTAGE MAY BE PRESENT AT ALL TIMES6X8" TYP - NEC 705.10SHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISION"ROGOVIN, REBECCA"18 WINSLOW AVE,NORTHAMPTON, MA 01062(413) 537-37951/5/2021MFSPV-7AF070817FREEDOM FOREVER - INDY 3.01 TEMPLATE ELECTRICAL CONTRACTOR NO:HOME IMPROVEMENT CONTRACTOR198080; BUSINESS ELECTRICALCONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTERELECTRICIAN 1136 MRFREEDOM FOREVER MASSACHUSETTSLLC135 ROBERT TREAT PAINE DR., TAUTON, MA 02780Tel: (800) 385-1075------------GREG ALBRIGHT 123456789101-1011-2021-3031-4041-5051-60123456789101-1011-2021-3031-4041-5051-60SHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISION"ROGOVIN, REBECCA"18 WINSLOW AVE,NORTHAMPTON, MA 01062(413) 537-37951/5/2021MFSPV-8F070817FREEDOM FOREVER - INDY 3.01 TEMPLATE ELECTRICAL CONTRACTOR NO:HOME IMPROVEMENT CONTRACTOR198080; BUSINESS ELECTRICALCONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTERELECTRICIAN 1136 MRFREEDOM FOREVER MASSACHUSETTSLLC135 ROBERT TREAT PAINE DR., TAUTON, MA 02780Tel: (800) 385-1075------------GREG ALBRIGHTENPHASE MICRO-INVERTER CHARTMICRO-INVERTERCHART SAFETY PLANSAFETY PLANMARK UP KEYINSTRUCTIONS:1.USE SYMBOLS IN KEY TO MARK UP THIS SHEET.2.SAFETY PLAN MUST BE MARKED BEFORE JOBSTARTS AS PART OF THE PRE-PLAN3.DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE& MAKE NOTES ON THE JHA SHEETIN CASE OF EMERGENCYNEAREST HOSPITAL OR OCCUPATIONAL/INDUSTRIAL CLINICNAME: _______________________________________________ADDRESS: ___________________________________________SAFETY COACH CONTACT INFORMATIONNAME: _______________________________________________ADDRESS: ___________________________________________ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THESAFETY PLAN AND SIGN INDICATING THAT THEY AREAWARE OF THE HAZARDS ON-SITE AND THE PLAN FORWORKING SAFELY. NAME SIGNATURE__________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ ________________DATE: ______________ TIME:___________________________PERMANENT ANCHORTEMPORARY ANCHORINSTALLER LADDERJUNCTION / COMBINER BOXSTUB-OUTSKYLIGHTNO LADDER ACCESS (STEEP GRADEOR GROUND LEVEL OBSTRUCTIONS)RESTRICTED ACCESSCONDUITGAS SHUT OFFWATER SHUT OFFSERVICE DROPPOWER LINESPTILBS7ZGASH2OSHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISION"ROGOVIN, REBECCA"18 WINSLOW AVE,NORTHAMPTON, MA 01062(413) 537-37951/5/2021MFSPV-9F070817FREEDOM FOREVER - INDY 3.01 TEMPLATE ELECTRICAL CONTRACTOR NO:HOME IMPROVEMENT CONTRACTOR198080; BUSINESS ELECTRICALCONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTERELECTRICIAN 1136 MRFREEDOM FOREVER MASSACHUSETTSLLC135 ROBERT TREAT PAINE DR., TAUTON, MA 02780Tel: (800) 385-1075------------GREG ALBRIGHT JOB HAZARD ANALYSISCrew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site CaptureLadder Access·Ladders must be inspected before each use.·Extension ladders must be set up on a firm and level surface ata 4-to-1 rise to run angle (or 75 degrees) and the top must besecured to the structure. Extension style ladders placed onuneven, loose or slippery surfaces must additionally have thebase firmly anchored or lashed so the base will not slip out.·Extension ladders must be used with walk-through devices orthe ladder must extend 36" above the stepping off point.·A-frame ladders must only be climbed with the ladder spreaderbars locked in the open position; A-frame ladders shall not beclimbed while in the closed position (ex, closed and used whileleaned against a structure).·Additional notes:Mobile Equipment·Only Qualified operators will operate equipment; operators mustmaintain a certification on their person for the equipment beingoperated.·Type(s) of mobile equipment (Type/Make/Model):·Qualified operator(s):Material Handling and Storage·Materials will be staged/stored in a way that does not present ahazard to client, personnel or public. Materials stored on theroof will be physically protect from failing or sliding off.Fall Protection·A site-specific plan for fall prevention and protection is requiredprior to starting work and must remain onsite at all times untilwork is complete; a fall rescue plan must be outlined anddiscussed among the crew prior to work start.·First-person-Up (FPU) must install their anchor and connectbefore any other task, including installing other anchors. TheLast-Person-Down (LPD) must be the only person on a roofuninstalling fall protection.·FPCP (name and title):·FPU and LPD (name and title):Electrical Safety·The Electrical Qualified Person (EQP) is required onsite toperform electrical work.·All electrical work will be performed with equipment in anelectrically safe condition (de-energized) unless approval hasbeen granted prior to work.·Service drops and overhead electrical hazards will beindentified and protected from contact, as neccessary.·EQP (name and tile):Public Protection·The safety of the Client and the Public must be maintained at alltimes.·The Client and the Public shall be prevented from entering thework zone through the use of barriers and/or signage, asrequired.·Company, Client and Public property shall be protect fromfalling objects.·Pets (including dogs) shall be secured by their owners prior towork start.·The client should not leave pets, family members, or others inthe charge or care of Employees, Contractors, or TemporaryWorkers.·Crew leader responsible for communication with the client:·Client and public is excluded from work area by barricades (N/A,Yes, No):Training and Pre-Job Safety Briefing·All employees onsite shall be made aware of the specifichazards of this project and review this HJA during a pre-jobbriefing, and their signature indicates awareness of siteconditions and the plan to eliminate any hazards identified priorto and during the project.·Crew leader (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):Airborne Contaminants:·Asbestos-containing (Transite) piping (ACP) - Do not disturb(move, drill, cut fracture, etc.)·Asbestos-containing thermal insulation (ACI) andAsbestos-containing duct wrapping (ACW) - do not disturb, noattic or crawlspace access is allowed if work to be performedcould cause exposure to personnel, client or public.·If yes, list specific tasks and protection in place:Weather and Environment·The site supervisor shall forecast the weather conditions at thejob site, prior to crew arrival, in order to mitigate any hazardsassociated with inclement weather (heat, cold, wind, rain, etc.)·The site supervisor will utilized a portable wind meter(anemometer) to verify actual onsite wind conditions, bychecking at the ground and on any elevated work surface (ex,rooftop) prior to work start, at midday and prior to solar panelstaging on a roof.·Elevated work involving the moving or maneuvering of solarpanels shall cease at 25mph (sustained wind) until windsubsides.·Forecasted weather maximum temp (degrees F):Heat Related Illness Prevention·Employees shall have access to potable drinking water that isfresh, pure, and suitably cool. The water shall be located asclose as practicable to the areas where employees are working.Water shall be supplied in sufficient quantity at the beginning ofthe work shift to provide at least one quart per employee perhour for drinking for the entire shift. Employees may begin theshift with smaller quantities of water if they identify the locationand have effective means for replenishment during the shift toallow employees to drink on quart or more per hour. Thefrequent drinking of water shall be encouraged.·Shade shall be present when temperature exceeds 80 degreesFahrenheit. When the outdoor temperature in the work exceeds80 degrees Fahrenheit, employees shall have and maintain oneor more areas with shade at all times.·New employees must be acclimatized. New employees will bemonitored by their Crew Leader (site supervisor) for the first two(2) weeks of employment or longer when necessary.·Employees will be allowed and encouraged to implementscheduled breaks during each shift. Employees must takecool-down breaks in the shade any time they feel the need to doso to protect them from overheating. Supervisors areREQUIRED to allow employees any break period they needduring high heat conditions.·Cool Vests are encouraged for all employees at all times duringperiods of high heat.·Identify the location of the closet Occupational/Industrial Clinicor Hospital in case a crew member becomes ill.What is the specific plan to provide and replenish sufficient water forall employees on site?·If offsite replenish is necessary, where will you go to replenishwater (location/address):·Who will replenish the drinking water (name):Restroom facilities·Employees shall have access to restroom facilities withhand-washing stations. Use of onsite restroom is at the client'sdiscretion (location is annotated below). If client does not givepermission, location of suitable restroom facilities withhand-washing stations offsite will be provided. The onsitesupervisor will identify location and make arrangements toensure all employees have access at any point.·Restroom facilities will be (circle one): Onsite - Offsite·If Offsite, add location name and address:Incident Reporting Procedure·Contact your Site SupervisorName:Phone:·Contact your ManagerName:Phone:·Contact your Site SupervisorName:Phone:With: Your full name, phone number, office location, brief descriptionof what happen and when.NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE(add as many as necessary by using additional sheets)Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:SHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISION"ROGOVIN, REBECCA"18 WINSLOW AVE,NORTHAMPTON, MA 01062(413) 537-37951/5/2021MFSPV-10F070817FREEDOM FOREVER - INDY 3.01 TEMPLATE ELECTRICAL CONTRACTOR NO:HOME IMPROVEMENT CONTRACTOR198080; BUSINESS ELECTRICALCONTRACTOR LICENSE 902-EL-A1;CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTERELECTRICIAN 1136 MRFREEDOM FOREVER MASSACHUSETTSLLC135 ROBERT TREAT PAINE DR., TAUTON, MA 02780Tel: (800) 385-1075------------GREG ALBRIGHTSAFETY PLAN experienceperformance355wp PowerELIGIBLE FORrec Alph black Series www.recgroup.com28 [1.1]1721±2.5 [67.75 ±0.1]802 [31.5]455 [17.9]956 [37.64]1016±2.5 [40 ±0.1]17 [0.7]45 [1.5] 1000 [39]1200 [47]11±0.2[0.43 ±0.8]6.6±0.2 [0.26 ±0.08]20.5±0.5[0.78 ±0.08]30 [1.18]22.5 [0.9] 621 ±3 [24.5 ±0.12] GRGR GR Ref: PM-Rev- D Specifications subject to change without notice.CERTIFICATIONSWARRANTYLOW LIGHT BEHAVIOURTEMPERATURE RATINGS*MAXIMUM RATINGSMeasurements in mm [in]100 200 300 400 500 600 700 800 900 1000859095100Irradiance (W/m²)Typical low irradiance performance of module at STC:Nominal Module Operating Temperature:°C (±°C)Temperature coefficient of PMAX:/°CTemperature coefficient of VOC:°CTemperature coefficient of ISC:°C*The temperature coefficients stated are linear valuesOperational temperature: ... +Maximum system voltage:Design load (+): snow Maximum test load (+): Pa (+ Pa ( )*Design load (-): wind Maximum test load (-): Pa (+ Pa ( )*Max series fuse rating: AMax reverse current: A+ Calculated using a safety factor of * See installation manual for mounting instructionsFounded in Norway in , REC is a leading vertically integrated solar energy company. Through integrated manufacturing from silicon to wafers, cells, high-quality panels and extending to solar solutions, REC provides the world with a reliable source of clean energy. REC’s renowned product quality is supported by the lowest warranty claims rate in the industry. REC is a Bluestar Elkem company with headquarters in Norway and operational headquarters in Singapore. REC employs around people worldwide, producing GW of solar panels annually. IEC IEC PIDIEC Salt MistAmmonia ResistanceFire Type Class Dynamic Mechanical LoadHailstone (mm)Cyclic Wind LoadISO :, ISO:, OHSAS :IEC StandardREC ProTrustInstalled by an REC Certified Solar ProfessionalNo Yes YesSystem Size All ≤ kW kWProduct Warranty (yrs)Power Warranty (yrs)Labor Warranty (yrs)Power in Year Annual DegradationPower in Year See warranty documents for details. Conditions apply. ELECTRICAL DATA Product Code*: RECxxxAA BlackPower Output - PMAX (Wp) /+/+/+/+/+Nominal Power Voltage - VMPP (V) Nominal Power Current - IMPP (A) Open Circuit Voltage - VOC (V) Short Circuit Current - ISC (A) Panel Efficiency () Power Output - PMAX (Wp)Nominal Power Voltage - VMPP (V) Nominal Power Current - IMPP (A) Open Circuit Voltage - VOC (V) Short Circuit Current - ISC (A) Values at standard test conditions (STC: air mass AM , irradiance W/m²), temperature °F (C), based on a production spread with a tolerance of PMAX, VOC & ISC ±, irradiance W/m², temperature °F (°C), windspeed m/s). * Where xxx indicates the nominal power class (PMAX) at STC above.GENERAL DATACell type: half-cut cells with REC heterojunction cell technology strings of cells in seriesGlass:in ( mm) solar glass with anti-reflection surface treatmentBacksheet:Highly resistant polymeric construction (black)Frame: Anodized aluminum (black)Junction box:-part, bypass diodes, rated in accordance with IEC Connectors:Stäubli ( mm²) in accordance with IEC only when connectedCable: AWG ( mm PV wire, + in ( + m)in accordance with EN Dimensions: x x in ( x x mm) m²)Weight: lbs (kg)Origin: Made in Singapore STC NMOTREC ALPH BLACK SERIESPRODUCT DATASHEET The S-5-E clamp is secured with our patented round-point setscrews without piercing the metal roof panel, thereby preserving the roof manufacturer's warranty!The right way to attach almost anything to metal roofs! S-5-E and S-5-E Mini888-825-3432 | www.S-5.com | S-5-E ClampThe S-5-E clamp is designed specially for double-folded standing seam roof profiles having the appropriate dimensioning.Although a bit smaller and less expensive than the S-5-U, for these profiles, the S-5-E is just as strong.The S-5-E is perfect for use with S-5!® ColorGard® snow retention systems and other heavy-duty applications.Installation is as simple as placing the clamp on the seam and tightening the patented round-point setscrews to the specified tension. Then, affix ancillary items using the bolt provided. Go to www.S-5.com/tools for information and tools available for properly attaching and tensioning S-5! clamps.S-5-E Mini ClampThe S-5-E Mini is a bit shorter than the S-5-E and has one setscrew rather than two. The mini is the choice for attaching all kinds of rooftop accessories: signs, walkways, satellite dishes, antennas, rooftop lighting, lightning protection systems, solar arrays, exhaust stack bracing, conduit, condensate lines, mechanical equipment—just about anything!**S-5! mini clamps are not compatible with, and should not be used with S-5! SnoRail™/SnoFence™ or ColorGard® snow retention systems.Distributed byS-5!® Warning! Please use this product responsibly!Products are protected by multiple U.S. and foreign patents. Visit the website at www.S-5.com for complete information on patents and trademarks. For maximum holding strength, setscrews should be tensioned and re-tensioned as the seam material compresses. Clamp setscrew tension should be verified using a calibrated torque wrench between 160 and 180 inch pounds when used on 22ga steel, and between 130 and 150 inch pounds for all other metals and thinner gauges of steel. Consult the S-5! website at www.S-5.com for published data regarding holding strength.Copyright 2015, Metal Roof Innovations, Ltd. S-5! products are patent protected. S-5! aggressively protects its patents, trademarks, and copyrights. Version 052115.The strength of the S-5-E clamp is in its simple design. The patented setscrews will slightly dimple the metal seam material but will not puncture it—leaving roof warranties intact.S-5-E Mini ClampS-5-E ClampPlease note: All measurements are rounded to the second decimal place.The S-5-E and S-5-E Mini clamps are each furnished with the hardware shown to the right. Each box also includes a bit tip for tightening setscrews using an electric screw gun. A structural aluminum attachment clamp, the S-5-E is compatible with most common metal roofing materials excluding copper. All included hardware is stainless steel. Please visit www.S-5.com for more information including CAD details, metallurgical compatibilities and specifications.The S-5-E and S-5-E Mini clamps have been tested for load-to-failure results on a variety of double-folded standing seam roofs, from leading manufacturers of panels and panel-forming machines. The independent lab test reports found on our website at www.S-5.com prove that S-5!® holding strength is unmatched in the industry.E[ample Pro¿lesFor horizontal seams under .5", crimp the seam to 180 degrees at desired clamp location.This illustration demonstrates crimping technique, NOT actual location of clamp.1.18" (30.00 mm)0.98" (25.00 mm)1.97" (50.00 mm)0.60" (15.00 mm)(2x) M8-1.25Threaded HoleM8-1.25Threaded Hole1.18" (30.00 mm)0.98" (25.00 mm)1.18" (30.00 mm)0.30" (7.60 mm)0.35" (8.90 mm)0.30" (7.60 mm)0.35" (8.90 mm)0.60" (15.00 mm)M8-1.25 X 16 mmHex Flange BoltM8-1.25 X 16 mmHex Flange BoltOne 3/8-24 X 0.80"Round-Point SetscrewsTwo 3/8-24 X 0.80"Round-Point Setscrews DQD 507 Rev. 2016-02-18 Page 1 Certificate of Compliance Certificate: 70131735 Master Contract: 266909 (266909) Project: 70185553 Date Issued: 2018-10-08 Issued to: Unirac 1411 Broadway NE Albuquerque, New Mexico 87102 USA Attention: Klaus Nicolaedis The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Michael Hoffnagle Michael Hoffnagle PRODUCTS CLASS - C531302 - POWER SUPPLIES- PHOTOVOLTAICS--PV Racking CLASS - C531382 - POWER SUPPLIES- PHOTOVOLTAICS-PV Racking and clamping systems-Certified to US Standards Models: SM SOLARMOUNT Flush-to-Roof is an extruded aluminum rail PV racking system that is installed parallel to the roof in landscape or portrait orientations. ULA Unirac Large Array is a ground mount system using the SolarMount (SM) platform for the bonding and grounding of PV modules. SOLARMOUNT The system listed is designed to provide bonding/grounding, and mechanical stability for photovoltaic modules. The system is secured to the roof with the L-Foot components through the roofing material to building structure. Modules are secured to the racking system with stainless steel or aluminum mid clamps and Aluminum end clamps. The modules are bonded to the racking system with the stainless steel bonding mid clamps with piercing points. The system is grounded with 10 AWG copper wire to bonding/grounding lugs. Fire ratings of Class A with Type 1, 2, 3, or 10 for steep slope. Tested at 5” interstitial gap which allows installation at any stand-off height. Certificate: 70131735 Project: 70185553 Master Contract: 266909 Date Issued: 2018-10-08 DQD 507 Rev. 2016-02-18 Page 2 The grounding of the system is intended to comply with the latest edition of the National Electrical Code, to include NEC 250 & 690. Local codes compliance is required, in addition to national codes. All grounding/bonding connections are to be torqued in accordance with the Installation Manual and the settings used during the certification testing for the current edition of the project report. The system may employ optimizers/micro-inverters and used for grounding when installed per installation instructions. Mechanical ratings: Downward Design Load (lb/ft²) 113.4 Upward Design Load (lb/ft²) 50.4 Down-Slope Load (lb/ft²) 14.7 Conditions of acceptability: Installation is subject to acceptance of the local inspection authorities having jurisdiction. The certification of these products relates only to the methods of installation, bonding, and grounding as outlined in the Installation Manual for each product. Unirac Large Array ULA is a ground mount system using the SolarMount (SM) platform for the bonding and grounding of PV modules. ULA aluminum components merge with SM rails and installer-supplied steel pipe. The SM rail system is secured to the horizontal Pipe using the Rail Bracket components. The Rear and Front cap secures the horizontal Pipe to the vertical Pipe. The Front cap is also used to secure the Cross brace. A Slider is attached to the vertical Pipe to secure the Cross brace. The SM rails, caps, slider, rail brackets, and cross braces materials are 6105-T5 aluminum extrusion. Fasteners materials are 304 stainless steel. Horizontal and vertical pipe materials meet the minimum requirements of ASTM A53 for galvanized steel pipe in 2” and 3” diameter. The mechanical load ratings from the SM test data will be applied to the ULA model. Fire Testing is not applicable due to being a ground mount system. APPLICABLE REQUIREMENTS UL 2703-1st Edition - Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels. LTR AE-001-2012 - List of Technical Requirements for Photovoltaic Module and Panel racking Systems MARKINGS The manufacturer is required to apply the following markings: x Products shall be marked with the markings specified by the particular product standard. x Products certified for Canada shall have all Caution and Warning markings in both English and French. Address: Intertek 3933 US 11 Cortland NY 13045 Telephone: 607-758-6516 www.intertek.com This information is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense, or damage occasioned by the use of this information. Any observations and results in this report are relevant only to the sample evaluated. Only the Client is authorized to copy and distribute this information and only then in its entirety. © 2018 Intertek Version: 8-September-2016 Page 1 of 3 GFT-OP-10a Subject: ETL Evaluation of SolarEdge Products to NEC 2017 Rapid Shutdown Requirements To, whom it may concern This letter represents the testing results of the below listed products to the requirements contained in the following standards: National Electric Code, 2017, Section 690.12 requirement for rapid shutdown. UL 1741, UL 1741 CRD for rapid shutdown The evaluation was done on the PV Rapid Shutdown System (PVRSS), and covers installations consisting of optimizers and inverters with part numbers listed below. The testing done has verified that controlled conductors are limited to: x Not more than 30 volts and 240 voltamperes within 30 seconds of rapid shutdown initiation outside the array. x Not more than 80 volts and 240 voltamperes within 30 seconds of rapid shutdown initiation inside the array. The rapid shutdown initiation is performed by either disconnecting the AC feed to the inverter, or – if the inverter DC Safety switch is readily accessible – by turning off the DC Safety switch. Applicable products: x Power optimizers: o PB followed by 001 to 350; followed by -AOB or -TFI. OP followed by 001 to 500; followed by -LV, -MV, -IV or -EV. P followed by 001 to 850. SP followed by 001 to 350. *When optimizers are connected to 2 or more modules in series, the max input voltage may exceed 80V. Following the implementation of the NEC 2017 rapid shutdown value of 80V max inside of the array at the beginning of 2019 , modules exceeding this combined input max voltage will be required to use optimizers with parallel inputs. x 1-ph Inverters: Address: Intertek 3933 US 11 Cortland NY 13045 Telephone: 607-758-6516 www.intertek.com This information is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense, or damage occasioned by the use of this information. Any observations and results in this report are relevant only to the sample evaluated. Only the Client is authorized to copy and distribute this information and only then in its entirety. © 2018 Intertek Version: 8-September-2016 Page 2 of 3 GFT-OP-10a o SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US / SE11400A-US / SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US when the following label is labeled on the side of the inverter: Inverter part number may be followed by a suffix x 3-ph Inverters: o SE9KUS / SE10KUS / SE14.4KUS / SE20KUS / SE30KUS / SE33.3KUS /SE43.2KUS / SE66.6KUS / SE100KUS ; when the following label is labeled on the side of the inverter: Inverter part number may be followed by a suffix If there are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact the undersigned. TÜV Rheinland PTL, LLC, 1107 W. Fairmont Drive, Building A, Tempe, Arizona 85282, Tel (480) 966-1700, Fax (775) 314-6458