Rick G 160 N Maple Revised 2nd Dormerinset of dormer wall from wall below
0' - 6"
match existing overhang of house
(square cut eaves)
provide room between
window trim & inside corner trim of new
wall & octagon window
match roof slope of existing
match roof slope of existing
4
12
provide apron roof across
addition
or option for friez board.
new floor line to match
existing 2nd floor height
(no step)
10' - 0"
existing
existaddition/renovation
N. Maple
new roof shingles to
match existing as
best as possible
step flash
Scale
Project number
Date
Drawn by
Checked by 21 west st. -west hatfield, ma. -01088 413.247.83001/4" = 1'-0"8/5/2020 12:56:33 PMA100
Cover sheet
Project Number
160 N. Maple St.
Florence, Ma
Dr. Richard Gerstein
Issue Date
Author
Checker
No. Description Date
1 Perspective View #1
Proposed Renovation & Expansion
of 2nd Floor Bedroom
@ 160 North Maple St. -Florence
1/4" = 1'-0"2 Rear Elevation
1/4" = 1'-0"3 Left Side Elevation
1/4" = 1'-0"4 Right Side Elevation
Existing Left Side Elevation Existing Right Side Elevation Existing Rear Elevation
DN
5' - 0"15' - 0"5' - 0"Exist
Laundry
Exist
Kitchen
exist
mud room
exist cellar
entrance
existing bath
double 2x10 rim
triple 2x10 @ ends
under walls
triple 2x10 @ ends
under walls
block along wall
plate height of outside
wall will need to be adjusted
( field verify )
existing bearing wall
existing framing to remain
existing bearing wall LUS210 into 2x10 ledger
spf #2 2x10 16" o.c.field verifycenter dormer on addition10' - 0"2x6 ladder frame
2x6 fascia
square-cut
to match existing
H2.5A hurricane ties
typical
LRU210
2x10 spf #2 16" o.c.2x10 spf #2 16" o.c.dormer wall inset 6" from wall belowHHUS410
HHUS410
LUS210-3
LUS210-3 2x10 spf #2 16" o.c.triple 2x10
triple 2x10
2ply 12" LVL3ply 2x12 2x12 ridge
2x6 fascia
square-cut
to match existing
LRU210
2ply 12" LVL
3ply 2x12
H2.5A hurricane ties
typical
2x10 spf #2 16" o.c.Existing
Bathroom
Existing
Loft / Bedroom
field verify dimension
remove sloped window
octagon window to remain
new wall
approx 3' +/-
high-match exist
roof plane height
19' - 8 1/2"
Bedroom
provide apron roof
for cover over door
existing
bedroom door
to remainlength of addition7'-6" x 1'-8 triple awning4
A101
19' - 8 1/2"line of dormerstud face to stud face3040 egressDH2840-2 DH
16' - 0"7'-6" x 1'-8 triple awningSecond Floor
8' -0"Header height6' - 8"0' - 6"
2x8 ceiling joist
rafter height determined by
existing roof plane & deducting
heel height of new 2x10 rafter
2ply 12" LVL
triple 2x12
header / roof trimmer
triple rafter trimmer beyond
2x6 spf #2 -16" o.c.
7/16" Zip wall sheathing w/ taped seams
double 2x6 top plate
single sole plate
1/2" gyp wall board interior
R-21 Batts insulation
Clap board siding / (see owner on material)
2x12 spf #2 ridge
continuious
2x10 spf #2 16" o.c.
rafter hieght determined by
existing roof plane & deducting
heel height of new 2x10 rafter
tie rafters outside of dormer rafters
@ ceiling line w/ 2x8 16" o.c.
(middle 3rd of span)
2x6 collar tie
16" o.c.
dormer walls & studs to sit on
triple trimmers of roof frame
(beyond)
LUS28-2-rafter & collar
hanger together
see floor framing
layout
3/4" advantch
glued & nained to joist 16" o.c.
LRU210
2x10 spf #2
16" o.c.
R-49
Field verify2ply 12" LVL
triple rafter trimmer beyond
LRU210
Scale
Project number
Date
Drawn by
Checked by 21 west st. -west hatfield, ma. -01088 413.247.8300As indicated
8/5/2020 12:56:34 PMA101
Plan Views / Section
Project Number
160 N. Maple St.
Florence, Ma
Dr. Richard Gerstein
Issue Date
Author
Checker
1/2" = 1'-0"1 First Floor
1/2" = 1'-0"2 Roof Framing Plan
1/4" = 1'-0"3 Second Floor
1/2" = 1'-0"4 Section 1
No. Description Date