31C-080 29 FORD CROSSING BP-2021-0069
GIS#: COMMONWEALTH OF MASSACHUSETTS
Map.Block:31 C-080 CITY OF NORTHAMPTON
Lot: -5 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Category:New Single Family House BUILDING P E RM I T
Permit# BP-2021-0069
Project# JS-2021-000098
Est.Cost: $390133.00
Fee:$1306.00 PERMISSION IS HEREBY GRANTED TO:
Const.Class: Contractor: License:
Use Group: WRIGHT BUILDERS 047146
Lot Size(sq.ft.): Owner: WRIGHT BUILDERS
Zonin . Applicant: WRIGHT BUILDERS
AT: 29 FORD CROSSING
Applicant Address: Phone: Insurance:
48 Bates St (413) 586-8287 (116) Workers Compensation
NORTHAMPTON MA01 060 ISSUED ON:7/21/2020 0:00:00
TO PERFORM THE FOLLOWING WORK.-NEW SINGLE FAMILY HOUSE
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House# Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Department Fireplace/Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Certificate of Occupancy Signature:
FeeType: Date Paid: Amount:
Building 7/21/2020 0:00:00 $1306.00
212 Main Street,Phone(413)587-1240, Fax:(413)587-1272
Louis Hasbrouck—Building Commissioner
��.
00,
a� o
The Commonwealth of Massachusetts o
Board of Building Regulations and Standards
tTY
"D Massachusetts State Building Code,780 CMR ,
�s
Building Permit Application To Construct,Repair;Renovate Or Demolish a 'Revised
One-or Two-Fancily Dwelling °so tis
This Section For Official Use Only
Building Permit Number. '-d Date Applied:
a� ao
Building Official(Print Name) Signature Date
SECTION 1:SITE INFORMATION
1.1 Property Address: 1:2 Assessors Map&Parcel Numbers
,)-I PDAD tt is � ��
1.1 a Is this an accepted street?yes no Map Number Parcel Number
1.3 Zoning Information: 1.4 Property Dimensions:
Zoning District Proposed Use Lot Area(sq h) Frontage(tt)
1.5 Building Setbacks(ft) fK ASS 5fr- l k4tVb x>ltbep '8 i
Front Yard Side Yards" Rear Yard
Required Provided Required Provided Required Provided
1.6 Water Supply:(M.G.L o.40,§54) 1.7 Flood Zone-Information: 1.8 Sewage Disposal System:
Public' Private❑ _ Zone: Outside Flood Zone? Muoicipal,<On site disposal system ❑
Check if yes
SECTION 2: PROPERTY OWNERSHIP'-
2.1 Owner'of Record:
Name(Print) City,State,ZIP•
No.and Street Telephone Email/Address
SECTION 3:DESCRIPTION OF PROPOSED WORK1(check all that apply)
New Construction)M Existing Building❑ Owner-Occupied ❑ 'Repairs(s) ❑' Ail taration(s) ❑ Addition ❑
Demolition D I Accessory Bldg.❑ Number of Units Other ❑ Specify:
Brief Description of Proposed Work2: NEW t) t't"W
SECTION 4:ESTIMATED CONSTRUCTION COSTS
Item Estimated Costs: Official Use Only
(Labor and Materials)
1.Building 1 ? ,.� .. 1, Building Permit Fee:$ Indicate how fee is determined:
❑Standard City/Town Application Fee
2.Electrical $ �� ❑Total Project Cost'(Item 6)x multiplier x
3.Plumbing S �S a 2. Other Fees: S
4.Mechanical (HVAC) S
i.
5.Mechanical (Fire S •.
Suppression) Total All Fie+ _ } Q
Check No7 heck Amount#: �" Cash Amount:
6.Total Project Cost: 1; ;901 ?�'1j,
1 0 Paid in Full ❑Outstanding Balance Due:
SECTION 5: CONSTRUCTION SERVICES
5.1 Construction Supervisor License(CSL)
W hf-r'LVI'(4 9)t K— tit PPNtW License Nuinber Expiration Date
Name of CSL-Holder
Wr^ List CSL Type(see below) V
No.and Street > Type Description
i �r U Unrestricted(Buildings u to 35,000 cu.ft.)
ivy f R Restricted•10Family Dwelling
Citymwn,State,ZIP M Masonry
RC Roofing Covering
WS Window and Siding
SF Solid Fuel.Buming Appliances
Insulation
Tele hone Em ' address D Demolition
5.2 Registered Rome Improvement Contractor(HiC) j 5-316
{ P,`eerr W i
1•LIC Registration Number Expiration Date
HIC Company_N.aaTnee orHIC Registrant Name ! t
i lir 1+G� �'t"• -- .
No.and StreetV ail address
City/Town,State,ZIPTele hone
SECTION 6:WORKERS' COMPIC,NSATION INSURANCE AFFIDAVIT(MG.L.c.152.§ 25C(6)) '
Workers Compensation Insurance affidavit must be completed and•submitted with this application. Failure to provide
this affidavit will result in the denial of the Issuance of the building permit.
Signed Affidavit Attached?' Yes..........� No...........D
SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN
OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT
I,as Owner of the subject property,hereby authorize ( b-4:x-- y 1,
to act on my behalf,in all matters relative to work authorized by this building permit application. .
Print Owner's Name(Electronic Signature) Date
SECTION 7b:OWNER'OR AU'T'HORIZED AGENT DECLARATION
By entering my name below,I hereby,attest under the pairis and penalties of perjury that all of the information
contained in this application is true and accurate to the best of my knowledge and understanding.
M A Ltb uyetAl Orr'kyl7 �
Print Owner's or Authorized Agent's Name(Electronic Signature) Date
NOTES:
1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor
(notregistered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration
program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at
xw w.mass.gov/oca Information on the Construction Supervisor License can be found at wwxv.mass.uov/dps
2. When substantial work is planned,provide the information below:
Total floor area(sq.fr.) (including garage,finished basement/attics,decks or porch)
Gross living area(sq.ft.) Habitable room count
Number of fireplaces Number of bedrooms
Number of bathrooms Number of half/baths
Type of heating system Number of decks/porches
Type of cooling system Enclosed Open
3. "Total Project Square Footage"maybe substituted for"Total Project Cost"
I •
CENTER FOR
EcoTechnology-
we make green make sense-
ENERGY EFFICIENCY PLAN
Lot 5 Meadow Run, Village Hill, Northampton MA
Conditioned Floor Area and Volume 3410 ft2, 28,985 ft3 (including basement
Building Type Single family detached
Bedrooms 4 (including basement)
Assumptions for Preliminary Home Energy Rating
CET has completed a Preliminary Home Energy Rating based on the construction plans you have provided. Any
energy features not listed below are assumed to meet the prescriptive requirements of the IECC 2015.
Building Envelope Specifications Used in Analysis
Foundation Walls R-21 Superior Wall Xi+
with R-15 fiberglass batts in cavities Grade I
Basement Slab 4"XPS (R-20) underneath
2"XPS R-10 at edge
Rim Joists 3" closed cell spray foam R-18
Double stud wall—two 2x4 stud walls with 3"space between
Exterior Walls Filled with densepack cellulose (R-35)
Walls capped at top plate and insulation enclosed by interior air barrier
(drywall and/or vapor retarder)
Walls to Garage Same as exterior walls
Windows Triple glazed, Argon gas filled, U-value = 0.23, SHGC = 0.21
Basement windows Double glazed, U-value = 0.30, SHGC = 0.29
Glass Doors Triple glazed, Argon gas filled, U-value = 0.23, SHGC = 0.21
Exterior Doors R-5/ U-0.20
Flat Ceilings 16" loose-blown cellulose (R-60), sealed eave baffles
Attic Hatches 8"XPS foam board (R-40), fully gasketed,
framed edge dam to height of surrounding insulation
Air Sealing & Blower Door Test Aerobarrier run until 0.6 ACH50 or better achieved
Thermal Enclosure Checklist Meet all Checklist Requirements as verified by a HERS rater at pre-
drywall and final inspection
Plumbing & Mechanical Systems Specifications Used in Analysis
Heating & Cooling Equipment: Single head ductless mini-split system
Living/Kitchen/Dining 13.3 HSPF, 25 SEER
Heating & Cooling Equipment: Bedrooms Multi head ductless mini-split system
10.4 HSPF, 16 SEER
Thermostats Programmable
Water Heating Equipment 2.33 EF heat pump water heater, 80 gallons
Domestic Hot Water Pipes Maximum of 20 feet total distance
from water heater to farthest fixture
Energy Recovery Ventilator, 40 watts
Whole House Ventilation 70% Sensible Recovery Efficiency, 50% Total Recovery Efficiency
86 CFM continuous airflow
ENERGY EFFICIENCY PLAN
Lighting & Appliances Specifications Used in Analysis
Lighting 100% LED, including interior, exterior, and garage
Refrigerator 550 kWh/year or less
Dishwasher ENERGY STAR certified
Clothes Washer ENERGY STAR certified
Clothes Dryer ENERGY STAR certified
Preliminary Home Energy Rating Results
Based on the assumptions described above, we have calculated the following Preliminary Home Energy Rating results.
Preliminary HERS Index: 38
Note that Confirmed Home Energy Rating results may vary from the Preliminary Home Energy Rating results due to
changes in building plans, energy features installed in the home, RESNET standards, software changes, and other
factors.
Preliminary Rater:Mark Newey
Date:7/20/2020
Job#: 19-03197-5
Page 2 of 2-The Center for EcoTechnology-Tel(413)586-7350 ext.242-Fax(413)586-7351 -greenhomeacetonline.org