Loading...
31C-080 29 FORD CROSSING BP-2021-0069 GIS#: COMMONWEALTH OF MASSACHUSETTS Map.Block:31 C-080 CITY OF NORTHAMPTON Lot: -5 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category:New Single Family House BUILDING P E RM I T Permit# BP-2021-0069 Project# JS-2021-000098 Est.Cost: $390133.00 Fee:$1306.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: WRIGHT BUILDERS 047146 Lot Size(sq.ft.): Owner: WRIGHT BUILDERS Zonin . Applicant: WRIGHT BUILDERS AT: 29 FORD CROSSING Applicant Address: Phone: Insurance: 48 Bates St (413) 586-8287 (116) Workers Compensation NORTHAMPTON MA01 060 ISSUED ON:7/21/2020 0:00:00 TO PERFORM THE FOLLOWING WORK.-NEW SINGLE FAMILY HOUSE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 7/21/2020 0:00:00 $1306.00 212 Main Street,Phone(413)587-1240, Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner ��. 00, a� o The Commonwealth of Massachusetts o Board of Building Regulations and Standards tTY "D Massachusetts State Building Code,780 CMR , �s Building Permit Application To Construct,Repair;Renovate Or Demolish a 'Revised One-or Two-Fancily Dwelling °so tis This Section For Official Use Only Building Permit Number. '-d Date Applied: a� ao Building Official(Print Name) Signature Date SECTION 1:SITE INFORMATION 1.1 Property Address: 1:2 Assessors Map&Parcel Numbers ,)-I PDAD tt is � �� 1.1 a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq h) Frontage(tt) 1.5 Building Setbacks(ft) fK ASS 5fr- l k4tVb x>ltbep '8 i Front Yard Side Yards" Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L o.40,§54) 1.7 Flood Zone-Information: 1.8 Sewage Disposal System: Public' Private❑ _ Zone: Outside Flood Zone? Muoicipal,<On site disposal system ❑ Check if yes SECTION 2: PROPERTY OWNERSHIP'- 2.1 Owner'of Record: Name(Print) City,State,ZIP• No.and Street Telephone Email/Address SECTION 3:DESCRIPTION OF PROPOSED WORK1(check all that apply) New Construction)M Existing Building❑ Owner-Occupied ❑ 'Repairs(s) ❑' Ail taration(s) ❑ Addition ❑ Demolition D I Accessory Bldg.❑ Number of Units Other ❑ Specify: Brief Description of Proposed Work2: NEW t) t't"W SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building 1 ? ,.� .. 1, Building Permit Fee:$ Indicate how fee is determined: ❑Standard City/Town Application Fee 2.Electrical $ �� ❑Total Project Cost'(Item 6)x multiplier x 3.Plumbing S �S a 2. Other Fees: S 4.Mechanical (HVAC) S i. 5.Mechanical (Fire S •. Suppression) Total All Fie+ _ } Q Check No7 heck Amount#: �" Cash Amount: 6.Total Project Cost: 1; ;901 ?�'1j, 1 0 Paid in Full ❑Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) W hf-r'LVI'(4 9)t K— tit PPNtW License Nuinber Expiration Date Name of CSL-Holder Wr^ List CSL Type(see below) V No.and Street > Type Description i �r U Unrestricted(Buildings u to 35,000 cu.ft.) ivy f R Restricted•10Family Dwelling Citymwn,State,ZIP M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel.Buming Appliances Insulation Tele hone Em ' address D Demolition 5.2 Registered Rome Improvement Contractor(HiC) j 5-316 { P,`eerr W i 1•LIC Registration Number Expiration Date HIC Company_N.aaTnee orHIC Registrant Name ! t i lir 1+G� �'t"• -- . No.and StreetV ail address City/Town,State,ZIPTele hone SECTION 6:WORKERS' COMPIC,NSATION INSURANCE AFFIDAVIT(MG.L.c.152.§ 25C(6)) ' Workers Compensation Insurance affidavit must be completed and•submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached?' Yes..........� No...........D SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize ( b-4:x-- y 1, to act on my behalf,in all matters relative to work authorized by this building permit application. . Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER'OR AU'T'HORIZED AGENT DECLARATION By entering my name below,I hereby,attest under the pairis and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. M A Ltb uyetAl Orr'kyl7 � Print Owner's or Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (notregistered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at xw w.mass.gov/oca Information on the Construction Supervisor License can be found at wwxv.mass.uov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.fr.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"maybe substituted for"Total Project Cost" I • CENTER FOR EcoTechnology- we make green make sense- ENERGY EFFICIENCY PLAN Lot 5 Meadow Run, Village Hill, Northampton MA Conditioned Floor Area and Volume 3410 ft2, 28,985 ft3 (including basement Building Type Single family detached Bedrooms 4 (including basement) Assumptions for Preliminary Home Energy Rating CET has completed a Preliminary Home Energy Rating based on the construction plans you have provided. Any energy features not listed below are assumed to meet the prescriptive requirements of the IECC 2015. Building Envelope Specifications Used in Analysis Foundation Walls R-21 Superior Wall Xi+ with R-15 fiberglass batts in cavities Grade I Basement Slab 4"XPS (R-20) underneath 2"XPS R-10 at edge Rim Joists 3" closed cell spray foam R-18 Double stud wall—two 2x4 stud walls with 3"space between Exterior Walls Filled with densepack cellulose (R-35) Walls capped at top plate and insulation enclosed by interior air barrier (drywall and/or vapor retarder) Walls to Garage Same as exterior walls Windows Triple glazed, Argon gas filled, U-value = 0.23, SHGC = 0.21 Basement windows Double glazed, U-value = 0.30, SHGC = 0.29 Glass Doors Triple glazed, Argon gas filled, U-value = 0.23, SHGC = 0.21 Exterior Doors R-5/ U-0.20 Flat Ceilings 16" loose-blown cellulose (R-60), sealed eave baffles Attic Hatches 8"XPS foam board (R-40), fully gasketed, framed edge dam to height of surrounding insulation Air Sealing & Blower Door Test Aerobarrier run until 0.6 ACH50 or better achieved Thermal Enclosure Checklist Meet all Checklist Requirements as verified by a HERS rater at pre- drywall and final inspection Plumbing & Mechanical Systems Specifications Used in Analysis Heating & Cooling Equipment: Single head ductless mini-split system Living/Kitchen/Dining 13.3 HSPF, 25 SEER Heating & Cooling Equipment: Bedrooms Multi head ductless mini-split system 10.4 HSPF, 16 SEER Thermostats Programmable Water Heating Equipment 2.33 EF heat pump water heater, 80 gallons Domestic Hot Water Pipes Maximum of 20 feet total distance from water heater to farthest fixture Energy Recovery Ventilator, 40 watts Whole House Ventilation 70% Sensible Recovery Efficiency, 50% Total Recovery Efficiency 86 CFM continuous airflow ENERGY EFFICIENCY PLAN Lighting & Appliances Specifications Used in Analysis Lighting 100% LED, including interior, exterior, and garage Refrigerator 550 kWh/year or less Dishwasher ENERGY STAR certified Clothes Washer ENERGY STAR certified Clothes Dryer ENERGY STAR certified Preliminary Home Energy Rating Results Based on the assumptions described above, we have calculated the following Preliminary Home Energy Rating results. Preliminary HERS Index: 38 Note that Confirmed Home Energy Rating results may vary from the Preliminary Home Energy Rating results due to changes in building plans, energy features installed in the home, RESNET standards, software changes, and other factors. Preliminary Rater:Mark Newey Date:7/20/2020 Job#: 19-03197-5 Page 2 of 2-The Center for EcoTechnology-Tel(413)586-7350 ext.242-Fax(413)586-7351 -greenhomeacetonline.org