1388 Title 5 Inspection Report 6-11-2020Owner
information is
required for
every page.
Commonwealth of Massachusetts
Title 5 Official Inspection For
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
1388 Westhampton Rd. Florence Me. 01062
Property Address
Owner's Name
same
Cityrrown
Ma 01062 06/11/20
State Zip Code Date of Inspection
Inspection results must be submitted on this form. Inspection forms may not be altered in any
way. Please see completeness checklist at the end of the form.
Important:
A. Inspector Information
When filling out
forms on the
computer, use
Ray Champagne
only the tab key
Name of Inspector
to move your
Whiteley Septic Service
cursor - do not
Company Name
use the return
key.
21 Old County Rd.
Company Address
Q
Southampton
Ma 01073
City/Town
State Zip Code
413-527-0057
S14118
rdwnA
Telephone Number
License Number
B. Certification
I certify that: 1 am a DEP approved system inspector in full compliance with Section 15.340 of Title
5 (310 CMR 15.000); 1 have personally inspected the sewage disposal system at the property address
listed above; the information reported below is true, accurate and complete as of the time of my
inspection; and the inspection was performed based on my training and experience in the proper function
and maintenance of on-site sewage disposal systems. After conducting this inspection I have determined
that the system:
1. ® Passes
2. ❑ Conditionally Passes
3. ❑ Needs Further Evaluation by the Local Approving Authority
4. ❑ Fails
4Sgnre<::Z���
06/11/20
InspectorDate
The system inspector shall submit a copy of this inspection report to the Approving Authority (Board
of Health or DEP) within 30 days of completing this inspection. If the system has a design flow of
10,000 gpd or greater, the inspector and the system owner shall submit the report to the appropriate
regional office of the DEP. The original form should be sent to the system owner and copies sent to
the buyer, if applicable, and the approving authority.
Please note: This report only describes conditions at the time of inspection and under the
conditions of use at that time. This inspection does not address how the system will perform
in the future under the same or different conditions of use.
t5insp.doc • rev. 7/2 612 01 8 Tire 5 official Inspection Form: Subsurface Sewage Disposal System • Page 7 of 18
Commonwealth of Massachusetts
Title 5 Official Inspection Form
_.. Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
1388 Westhampton Rd. Florence Ma. 01062
Property Address
Gerald Cotter
Owner Owner's Name
information is
required for same Me 01062 06/11/20
every page. Cityrrown State Tip Code Date of Inspection
C. Inspection Summary
Inspection Summary: Complete 1, 2, 3, or 5 and all of 4 and 6.
1) System Passes:
® I have not found any information which indicates that any of the failure criteria described
in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are
indicated below.
Comments:
This system consists of a 1500 single compartment septic tank with concrete baffles and a d box with
2 inverts into trenches 45' long.
2) System Conditionally Passes:
❑ One or more system components as described in the "Conditional Pass" section need to be
replaced or repaired. The system, upon completion of the replacement or repair, as approved by
the Board of Health, will pass.
Check the box for "yes", "no" or "not determined" (Y, N, ND) for the following statements. If "not
determined," please explain.
The septic tank is metal and over 20 years old* or the septic tank (whether metal or not) is
structurally unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System
will pass inspection if the existing tank is replaced with a complying septic tank as approved by the
Board of Health.
* A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of
Compliance indicating that the tank is less than 20 years old is available.
❑ Y ❑ N ❑ ND (Explain below):
t5insp.doc • rev. 72612018 Tile 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 2 of 18
Owner
information is
required for
every page.
Commonwealth of Massachusetts
Title 5 Official Inspection For
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
1388 Westhampton Rd. Florence Ma. 01062
Property Address
Gerald Cotter
same Ma 01062
Citylrown State Zip Code
C. Inspection Summary (cont.)
2) System Conditionally Passes (cont.):
06/11/20
Date of
❑ Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if
pumps/alarms are repaired.
❑ Observation of sewage backup or break out or high static water level in the distribution box due
to broken or obstructed pipe(s) or due to a broken, settled or uneven distribution box. System will
pass inspection if (with approval of Board of Health):
❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below):
❑ obstruction is removed ❑ Y ❑ N ❑ NO (Explain below):
❑ distribution box is leveled or replaced ❑ Y ❑ N ❑ ND (Explain below):
❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The
system will pass inspection if (with approval of the Board of Health):
❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below):
❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below):
3) Further Evaluation is Required by the Board of Health:
❑ Conditions exist which require further evaluation by the Board of Health in order to determine if
the system is failing to protect public health, safety or the environment.
a. System will pass unless Board of Health determines in accordance with 310 CMR
15.303(1)(b) that the system is not functioning in a manner which will protect public health,
safety and the environment:
t5insp.doc • rev. 7/26/2018 Tito 5Of ficial Inspection Form: Subsurface Sewage Disposal System • Page 3 of 18
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
1388 Westhampton Rd. Florence Ma. 01062
Property Address
Gerald Cotter
Owner Owner's Name
information is
required for same Ma 01062 06/11/20
every page. Cityrrown State Zip Code Date of Inspection
C. Inspection Summary (cont.)
❑ Cesspool or privy is within 50 feet of a surface water
❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh
b. System will fail unless the Board of Health (and Public Water Supplier, if any)
determines that the system is functioning in a manner that protects the public health,
safety and environment:
❑ The system has a septic tank and scil absorption system (SAS) and the SAS is within
100 feet of a surface water supply or tributary to a surface water supply.
❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water
supply.
❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water
supply well.
❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or
more from a private water supply well**.
Method used to determine distance:
** This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal
coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal
to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must
be attached to this form.
c. Other:
4) System Failure Criteria Applicable to All Systems:
You must indicate "Yes" or "No" to each of the following for all inspections:
Yes No
El ® Backup of sewage into facility or system component due to overloaded or
clogged SAS or cesspool
El ® Discharge or ponding of effluent to the surface of the ground or surface waters
due to an overloaded or clogged SAS or cesspool
t5insp.doc • rev. 7/2612018 Tite 50Poclal Inspection Form: Subsurface Sewage Disposal System • Page 4 of 78
_\ Commonwealth of Massachusetts
_ � Title 5 Official Inspection Form
�+. Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
(T'
1388 Westhampton Rd. Florence Ma. 01062
Property Address
Gerald Cotter
Owner Owner's Name
information is
required for same Me 01062 06/11/20
every page. Cityfrown State Zip Code Date of Inspection
C. Inspection Summary (cont.)
4) System Failure Criteria Applicable to All Systems: (cont.)
Yes No
El ®
Static liquid level in the distribution box above outlet invert due to an overloaded
or clogged SAS or cesspool
El ®
Liquid depth in cesspool is less than 6" below invert or available volume is less
than '/z day flow
El ®
Required pumping more than 4 times in the last year NOT due to clogged or
obstructed pipe(s). Number of times pumped:
❑ ®
Any portion of the SAS, cesspool or privy is below high ground water elevation.
El ®
Any portion of cesspool or privy is within 100 feet of a surface water supply or
tributary to a surface water supply.
❑ ®
Any portion of a cesspool or privy is within a Zone 1 of a public water supply
well.
❑ ®
Any portion of a cesspool or privy is within 50 feet of a private water supply well.
❑ ®
Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet
from a private water supply well with no acceptable water quality analysis. [This
system passes if the well water analysis, performed at a DEP certified
laboratory, for fecal coliform bacteria indicates absent and the presence
of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,
provided that no other failure criteria are triggered. A copy of the analysis
and chain of custody must be attached to this form.]
❑ ®
The system is a cesspool serving a facility with a design flow of 2000 gpd-
10,000 gpd.
❑ ®
The system fails. I have determined that one or more of the above failure
criteria exist as described in 310 CMR 15.303, therefore the system fails. The
system owner should contact the Board of Health to determine what will be
necessary to correct the failure.
5) Large Systems: To be considered a large system the system must serve a facility with a
design flow of 10,000 gpd to 15,000 gpd.
For large systems, you must indicate either 'yes" or "no" to each of the following, in addition to the
questions in Section C.4.
Yes No
❑ ❑ the system is within 400 feet of a surface drinking water supply
❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply
El 11 Area
system is located in a nitrogen sensitive area (Interim Wellhead Protection
Area — IWPA) or a mapped Zone II of a public water supply well
t5lnsp.doc • rev. 7/26/2018 Title 50Rclal Inspection Form: Subsurface Sewage Disposal System • Page 5 of 18
Commonwealth of Massachusetts
�.— - Title 5 Official Inspection Form
( Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
1388 Westhampton Rd. Florence Ma. 01062
Property Address
Gerald Cotter
Owner Owner's Name
information is
required for same Ma 01062 06/11/20
every page. Cityrrown State Zip Code Date of Inspection
C. Inspection Summary (cont.)
If you have answered "yes" to any question in Section C.5 the system is considered a significant
threat, or answered "yes" to any question in Section C.4 above the large system has failed. The
owner or operator of any large system considered a significant threat under Section C.5 or failed
under Section C.4 shall upgrade the system in accordance with 310 CMR 15.304. The system owner
should contact the appropriate regional office of the Department.
6. You must indicate "yes" or "no" for each of the following for all inspections:
Yes No
® ❑ Pumping information was provided by the owner, occupant, or Board of Health
❑ ® Were any of the system components pumped out in the previous two weeks?
® ❑ Has the system received normal flows in the previous two week period?
El ® Have large volumes of water been introduced to the system recently or as part of
this inspection?
El ® Were as built plans of the system obtained and examined? (If they were not
available note as N/A)
® ❑ Was the facility or dwelling inspected for signs of sewage back up?
® ❑
Was the site inspected for signs of break out?
® ❑
Were all system components, excluding the SAS, located on site?
® ❑
Were the septic tank manholes uncovered, opened, and the interior of the tank
inspected for the condition of the baffles or tees, material of construction,
dimensions, depth of liquid, depth of sludge and depth of scum?
❑ ®
Was the facility owner (and occupants if different from owner) provided with
information on the proper maintenance of subsurface sewage disposal systems?
The size and location of the Soil Absorption System (SAS) on the site has
been determined based on:
❑ ❑
Existing information. Fcr example, a plan at the Board of Health.
® El
in the field (if any of the failure criteria related to Part C is at issue
approximation
approximation of distance is unacceptable) 1310 CMR 15.302(5)]
t5lnsp.doc - rev. 7/26/2018 Tito 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 6 of 18
Commonwealth of Massachusetts
Title 5 Official Insp
Subsurface Sewage Disposal System Fo
- (P
1388
D. System Information
1. Residential Flow Conditions:
Number of bedrooms (design): estimate4 Number of bedrooms (actual): 4
DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x # of bedrooms): estimate 440
Description:
The system is 24 yrs old and all levels are correct. All components are sound at this inspection. The
system is vented thru roof. The 2 leach trenches are 45' long. No signs of hydraulic failure was
observed
Number of current residents: 3
Does residence have a garbage grinder? ❑ Yes ® No
Does residence have a water treatment unit? ❑ Yes ® No
If yes, discharges to:
ection
For
Is laundry on a separate sewage system? (Include laundry system inspection
rm - Not for Voluntary Assessments
®
No
information in this report.)
4 ,
Westhampton
Rd. Florence Ma. 01062
❑ Yes
®
Property Address
Seasonal use?
❑ Yes
®
Gerald Cotter
Water meter readings, if available (last 2 years usage (gpd)):
well
Owner
Owner's Name
Detail:
information is
well 130' from d box
required for
same
Ma
01062 06/11/20
every page.
Citylrown
State
Zip Code Date of insnection
D. System Information
1. Residential Flow Conditions:
Number of bedrooms (design): estimate4 Number of bedrooms (actual): 4
DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x # of bedrooms): estimate 440
Description:
The system is 24 yrs old and all levels are correct. All components are sound at this inspection. The
system is vented thru roof. The 2 leach trenches are 45' long. No signs of hydraulic failure was
observed
Number of current residents: 3
Does residence have a garbage grinder? ❑ Yes ® No
Does residence have a water treatment unit? ❑ Yes ® No
If yes, discharges to:
Is laundry on a separate sewage system? (Include laundry system inspection
❑ Yes
®
No
information in this report.)
Laundry system inspected?
❑ Yes
®
No
Seasonal use?
❑ Yes
®
No
Water meter readings, if available (last 2 years usage (gpd)):
well
Detail:
well 130' from d box
Sump pump?
❑ Yes
®
No
presently
Last date of occupancy:
Date
t5lnsp.doc • rev. 7/26/2018 Title 5 Oficial Inspection Form: Subsurface Sewage Disposal System • Page 7 of 18
c Commonwealth of Massachusetts
Title 5 Official Inspection For
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
1388 Westhampton Rd. Florence Ma. 01062
Property Address
Gerald Cotter
Owner Owner's Name
information is
required for same Ma 01062 06/11/20
every page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
2. Commercial/Industrial Flow Conditions:
Type of Establishment:
Design flow (based on 310 CMR 15.203):
Basis of design flow (seats/persons/sq.ft., etc.):
Grease trap present?
Water treatment unit present?
If yes, discharges to:
Industrial waste holding tank present?
Non -sanitary waste discharged to the Title 5 system?
Water meter readings, if available:
Last date of occupancy/use:
Other (describe below):
3. Pumping Records:
Source of information:
Was system pumped as part of the inspection?
If yes, volume pumped:
How was quantity pumped determined?
Reason for pumping:
at inspection
1500
gallons
Maintenance
Gallons per day (gpd)
❑ Yes ❑ No
❑ Yes ❑ No
❑ Yes ❑ No
❑ Yes ❑ No
® Yes ❑ No
t5insp.doc • rev. 7128/2018 Tite 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 8 of 18
Owner
information is
required for
every page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
1388 Westhampton Rd. Florence Ma. 01062
Property Address
Gerald Cotter
Owners Name
same Ma 01062
Cityfrown State Zip Codi
D. System Information (cont.)
4. Type of System:
® Septic tank, distribution box, soil absorption system
❑ Single cesspool
❑ Overflow cesspool
06/11/20
Date of Inspection
❑ Privy
❑ Shared system (yes or no) (if yes, attach previous inspection records, if any)
❑ Innovative/Alternative technology. Attach a copy of the current operation and
maintenance contract (to be obtained from system owner) and a copy of latest
inspection of the I/A system by system operator under contract
❑ Tight tank. Attach a copy of the DEP approval.
❑ Other (describe):
Approximate age of all components, date installed (if known) and source of information:
Were sewage odors detected when arriving at the site?
5. Building Sewer (locate on site plan):
Depth below rade: 24
P g feet
Material of construction:
❑ cast iron ® 40 PVC ❑ other (explain): —
Distance from private water supply well or suction line: feet
feet
Comments (on condition of joints, venting, evidence of leakage, etc.):
no evidence of leakage observed
❑ Yes ® No
t5lnsp,doc • rev. 7/26/2018 Title 5 Oficial Inspection Form: Subsurface Sewage Disposal System • Page 9 of 18
Commonwealth of Massachusetts
Title 5 Official Inspection Form
l- Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
1 / 1388 Westhampton Rd. Florence Ma. 01062
Property Address
Gerald Cotter
Owner Owner's Name
information is
required for same Ma 01062 06/11/20
every page. Cityrrown State Zip Code Date of Inspection
D. System Information (cont.)
6. Septic Tank (locate on site plan):
Depth below grade: 24
feet
Material of construction:
® concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other (explain)
If tank is metal, list age: years
Is age confirmed by a Certificate of Compliance? (attach a copy of certificate) ❑ Yes ❑ No
Dimensions: 1500
Sludge depth: 1
Distance from top of sludge to bottom of outlet tee or baffle 34"
Scum thickness 2
Distance from top of scum to top of outlet tee or baffle 4
Distance from bottom of scum to bottom of outlet tee or baffle 18
How were dimensions determined?
Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
recommend pumping schedule of 2 yrs. All levels are correct.
t5insp.doc • rev. 7/2612018 Titin 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 10 of 1s
Owner
information is
required for
every page.
Commonwealth of Massachusetts
Title 5 Official Inspection For
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
1388 Westhampton Rd. Florence Ma. 01062
Property Address
Gerald Cotter
Owner's Name
same
Citylrown
D. System Information (cont.)
7. Grease Trap (locate on site plan):
Depth below grade:
Material of construction:
❑ concrete ❑ metal
Dimensions:
Scum thickness
Ma 01062
State Zio Code
❑ fiberglass
Distance from top of scum to top of outlet tee or baffle
Distance from bottom of scum to bottom of outlet tee or baffle
Date of last pumping:
06/11/20
Date of Inspection
feet
❑ polyethylene ❑ other (explain):
Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
Outlet baffle is sound D box is also sound with slight carryover. All levels are correct
B. Tight or Holding Tank (tank must be pumped at time of inspection) (locate on site plan):
Depth below grade:
Material of construction:
❑ concrete ❑ metal ❑ fiberglass
Dimensions:
Capacity:
Design Flow:
gallons
gallons per
❑ polyethylene ❑ other (explain):
t5lnsp.doc • rev. 71261201 B Tito 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 11 of 18
Commonwealth of Massachusetts
- _- Title 5 Official Inspection For
h Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
1388 Westhampton Rd. Florence Ma. 01062
Property Address
Gerald Cotter
Owner Owner's Name
information is
required for same Ma 01062 06/11/20
every page. cityr town State Zip Code Date of Inspection
D. System Information (cont.)
8. Tight or Holding Tank (cont.)
Alarm present:
Alarm level:
Date of last pumping:
❑ Yes ❑ No
Alarm in working order: ❑ Yes ❑ No
Comments (condition of alarm and float switches, etc.):
"Attach copy of current pumping contract (required). Is copy attached? ❑ Yes ❑ No
9. Distribution Box (if present must be opened) (locate on site plan):
Depth of liquid level above outlet invert 0
Comments (note if box is level and distribution to outlets equal, any evidence of solids carryover, any
evidence of leakage into or out of box, etc.):
distributing evenly and levels are correct with slight carryover in d box observed
t5insp.doe • rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 12 of 18
Commonwealth of Massachusetts
-_ Title 5 Official Inspection For
�- Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
1388 Westhampton Rd. Florence Me. 01062
Property Address
Gerald Cotter
Owner Owner's Name
information is
required for same Ma 01062 06/11/20
every page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
10. Pump Chamber (locate on site plan):
Pumps in working order: ❑ Yes ❑ No*
Alarms in working order: ❑ Yes ❑ No*
Comments (note condition of pump chamber, condition of pumps and appurtenances, etc.):
t5lnsp.doc • rev. 7/2612018 Titin 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 13 of 18
* If pumps
or alarms are not in working order, system is a conditional pass.
11. Soil Absorption System (SAS) (locate on site plan, excavation not required):
If SAS not located, explain why:
Type:
❑
leaching pits
number:
❑
leaching chambers
number:
❑
leaching galleries
number:
®
leaching trenches
number, length: 2x45
❑
leaching fields
number, dimensions:
❑
overflow cesspool
number:
❑
innovative/alternative system
Type/name of technology:
t5lnsp.doc • rev. 7/2612018 Titin 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 13 of 18
<\ Commonwealth of Massachusetts
Title 5 Official Inspection For
�- Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
1388 Westhampton Rd. Florence Ma. 01062
Property Address
Gerald Cotter
Owner Owner's Name
information is
required for
every page.
City/Town
D. System Information (cont.)
11. Soil Absorption System (SAS) (cont.)
Ma 01062 06/11/20
State Zip Code Date of Inst
Comments (note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of
vegetation, etc.):
no signs of hydraulic failure observed -- laver. area soil is sand and gravel rocky
12. Cesspools (cesspool must be pumped as part of inspection) (locate on site plan):
Number and configuration
Depth — top of liquid to inlet invert
Depth of solids layer
Depth of scum layer
Dimensions of cesspool
Materials of construction
Indication of groundwater inflow
❑ Yes ❑ No
Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
t5lnsp.doc • rev. 7/26/2818 Title 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 14 of 18
Commonwealth of Massachusetts
Title 5 Official Inspection For
�- Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
1388 Westhampton Rd. Florence Ma. 01062
Property Address
Gerald Cotter
Owner Owner's Name
information is
required for same Ma 01062 06/11/20
every page. Citylrown State Zip Code Date of Inspection
D. System Information (cont.)
13. Privy (locate on site plan):
Materials of construction:
Dimensions
Depth of solids
Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
t5lnsp.doe • rov. 7/26/2018 Title 5 Oficial Inspection Form: Subsurface Sewage Disposal System • Page 15 of 18
Commonwealth of Massachusetts
- -_ -Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
1388 Westhampton Rd. Florence Ma. 01062
Property Address
Owner
information is
required for
every page.
Gerald Cotter
owners marine
Ma 01062 06/11/20
State Zip Code Date of Inspection
D. System Information (cont.)
14. Sketch Of Sewage Disposal System:
Provide a view of the sewage disposal system, including ties to at least two permanent reference
landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters
the building. Check one of the boxes below:
® hand -sketch in the area below
❑ drawing attached separately
t5lnsp.doc - rev. 72612818 Title 5Official Inspection Form: Subsudace Sewage Disposal System • Page 16 of 18
Commonwealth of Massachusetts
_ Title 5 Official Ins
Subsurface Sewage Disposal System Fo
D. System Information (cont.)
15. Site Exam:
® Check Slope
® Surface water
® Check cellar
® Shallow wells
Estimated depth to high ground water: 6
feet
Please indicate all methods used to determine the high ground water elevation:
❑ Obtained from system design plans on record
If checked, date of design plan reviewed: Date
® Observed site (abutting property/observation hole within 150 feet of SAS)
❑ Checked with local Board of Health - explain:
❑ Checked with local excavators, installers - (attach documentation)
❑ Accessed USGS database - explain:
You must describe how you established the high ground water elevation:
no sump pump and known sandy gravel soil area
Before filing this Inspection Report, please see Report Completeness Checklist on next page.
tslnsp.dac • rev. 7/2612018 Tito 5 Oficial Inspection Form: Subsurface Sewage Disposal System • Page 17 of 18
ection
For
rm - Not for Voluntary Assessments
1388 Westhampton
Rd. Florence Ma. 01062
Property Address
Gerald Cotter
Owner
Owner's Name
information is
required for
same
Ma
01062 06/11/20
every page.
City/Town
State
Zip Code Date of Inspection
D. System Information (cont.)
15. Site Exam:
® Check Slope
® Surface water
® Check cellar
® Shallow wells
Estimated depth to high ground water: 6
feet
Please indicate all methods used to determine the high ground water elevation:
❑ Obtained from system design plans on record
If checked, date of design plan reviewed: Date
® Observed site (abutting property/observation hole within 150 feet of SAS)
❑ Checked with local Board of Health - explain:
❑ Checked with local excavators, installers - (attach documentation)
❑ Accessed USGS database - explain:
You must describe how you established the high ground water elevation:
no sump pump and known sandy gravel soil area
Before filing this Inspection Report, please see Report Completeness Checklist on next page.
tslnsp.dac • rev. 7/2612018 Tito 5 Oficial Inspection Form: Subsurface Sewage Disposal System • Page 17 of 18
Commonwealth of Massachusetts
Title 5 Official Inspection For
— Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
°y(
1388 Westhampton Rd. Florence Ma. 01062
Property Address
Gerald Cotter
Owner Owner's Name
information is
required for same Ma 01062 06/11/20
every page, City/Town State Zip Code bate of Inspection
E. Report Completeness Checklist
Complete all applicable sections of this form inclusive of:
® A. Inspector Information: Complete all fields in this section.
® B. Certification: Signed & Dated and 1, 2, 3, or 4 checked
® C. Inspection Summary:
1, 2, 3, or 5 completed as appropriate
4 (Failure Criteria) and 6 (Checklist) completed
® D. System Information:
For 8: Tight/Holding Tank – Pumping contract attached
For 14: Sketch of Sewage Disposal System drawn on pg. 16 or attached
For 15: Explanation of estimated depth to high groundwater included
t5insp.doc • rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System • Page 18 of 18