32C-067 (27) 2 CONZ ST - HEMPEST SM-2020-0042
COMMONWEALTH OF MASSACHUSETTS
CITY OF NORTHAMPTON
GIS#: 10123
Map: 32C
Block: 067 SHEETM ETAL PERMIT
Lot: 001 `
Permit: 'SHEETMETAL
Category: SHEETMETAL
Permit## SM-2020-0042 PERMISSION IS HEREBY GRANTED TO:
Project# JS-2020-001412
Est.Cost: $11,500.00 Contractor: License: Expires:
'Fee Charged:'$100.00 NOLAN PLUMBING&HEATING Sheetmetal-9758 08/28/2020
Balance Due:$.00 Owner: NORTHEMPTON ENTERPRISES INC
#of Fixtures:: Applicant: NOLAN PLUMBING&HEATING
i
DigSafe :AT: 2 CONZ ST- HEMPEST
UseGroup
ConstC lass
ISSUED ON: 21-May-2020 AMENDED ON: EXPIRES ON:
TO PERFORM THE FOLLOWING WORK:
EXPANSION&RENO OF EXISTING SPACE
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Signature:
Fee Type: Receipt No: Date Paid: Check No: Amount:
Sheetmetal REC-2020-003198 20-May-20 600 $100.00
212 Main Street,Phone:(413);87-1240,Fax:(413)587-1272,Email:lhasbrouckid-norihamptonma.�;u�
GeoTMS%2020 Des Lauriers Municipal Solutions,Inc.
Commonwealth of Massachusetts
City Of Northampton
Date:, Sheet Metal Permit Permit#
Estimated Job Cost: $ 1Permit Fee: $ 1V
CD —T
�lans'Sul�mitted: YES NO Plans Reviewed: YES NO
Business icense# Applicant License #
Business Information: Property Owner/Job Location Information:
Name:NOI(A P(OM ti;V,�1Gcf ihC Name: W ct4 �h1evp%1�kS \t\C
Street: ( C 1 c,v- i. !�A v Street: '2 CGI? Z S�rte 7
City/Town: GrTv&M mo, City/Town:
Telephone: H 13 S 2Telephone:
Photo I.D. required/Copy of Photo I.D. attached: YES NO
Staff Initial
J-1 4 -1-unrestricted license`
J-2/M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft./2-stories or less
Residential: 1-2 family Multi-family Condo/Townhouses Other
Commercial: Office ," Retail Industrial Educational
Institutional Other
Square Footage: under 10,000 sq. ft. /-over 10,000 sq. ft. Number of Stories:
Sheet metal work to be completed: New Work: Renovation:
HVAC Metal Watershed Roofing Kitchen Exhaust System
Metal Chimney/Vents Air Balancing
Provide detailed description of work to be done:
i 4 S-CAkkOA`,0n, p�y6w k, sok $Nk) SL V01 r1 ."i cctcc I
ayj 2 fbr\ cnu44onc cr,-ri , �`�� s�allc,�l'r,vi dF S�D1� e(4, 'i
5,2(of f0 odea I uvms 2ucA ui 4o 6e
-to tr At4 M q �oc�
Fees with Building Permit: $25.00 Residential, $50.00 Commercial. Fees for jobs without a Building Permit$6.00 per$1000
Minimum fees for jobs without Building Permit$50.00 Residential,$100.00 Commercial
INSURANCE COVERAGE:
have a current liar insurance policy or its equivalent which meets the requirements of M.G.L. Ch. 112 Yes JNO❑
If you have checked Yes, indicate the type of coverage by checking the appropriate box below:
1
A liability insurance policy d Other type of indemnity ❑ Bond ❑
OWNER'S INSURANCE WAIVER: I am aware that the licensee dnac not have the insurance coverage required by Chapter 112 of the
Massachusetts General Laws,and that my signature on this permit application waive this requirement.
Check One Only
Owner ❑ Agent ❑
Signature of Owner or Owner's Agent
By checking this boxLJ, I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and
accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be
in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws.
Duct inspection required prior to insulation installation: YES NO
Progr"s luspertinnc
Date Comments
Final 1nSpoCt._.i_nn
D:.I.I.e f llllll]L1115
Type of License:
BY ❑ Master
Title ❑ Master-Restricted
City/Town ❑Journeyperson
Signature of Licensee
Permit#
❑J ou rneyperson-Restricted
License Number'
Fee$ ❑
Check at www mass goviripi
Inspector Signature of Permit Approval
MASSACHUSETTS DRIVER'S
I NUMBER
0811412019 S65193527
EXP 0812612024 08126!1974
py t CtA55 RES? .END
D NONE NONE
Wii:�NKO
ROBERT FRANCIS
a 113 FRANKLIN ST
GREENFIELD,MA 01301-2916
} A BLU
SEX M
DDD HGT 5'-10" �+
DD 08115!1079 Rer 07/71/2016 OVQ I2V//
OMMONWEALTH OF MASSA HUS
- • • • - • •
BOARD OF
SHEET METAL WORKERS I
}y� ISSUES THE. FOLLOWING LICENSE I
MASTER-UNRESTRICTED
C
a �
d � I
f ROBERT F MENKO
y
113 FRANKLIN ST w.
w
GREENFIELD,MA 01301-2916 W
U
J
534615
9758 0812812020 }
The Commonwealth of Massachusetts
Department of Industrial Accidents
1 Congress Street, Suite 100
Boston,MA 02114-2017
www.mass.gov/dia
Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers.
TO BE FILED WITH THE PERMITTING AUTHORITY.
Applicant Information Please Print LeLlibIN
Name (Business/Organization/Individual):NOLAN PLUMBING & HVAC INC
Address:26 CLARK STREET
City/State/Zip:GREENFIELD MA 01301 Phone#:4138242204
Are you an employer?Check the appropriate box: Type of project(required):
1.[]I am a employer with 3 employees(full and/or part-time).* 7. ✓❑New construction
2.[]1 am a sole proprietor or partnership and have no employees working for me in 8. Remodeling
any capacity.[No workers'comp.insurance required.]
9. ❑Demolition
3.1 1 am a homeowner doing all work myself.[No workers'comp.insurance required.]t
10 Building addition
4.[:]l am a homeowner and will be hiring contractors to conduct all work on my property. I will
ensure that all contractors either have workers'compensation insurance or are sole 11.[:]Electrical repairs or additions
proprietors with no employees. 12.❑Plumbing repairs or additions
❑I am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13.E:]Roof repairs
fhese sub-contractors have employees and have workers'comp.insurance.
6.❑We are a corporation and its officers have exercised their right of exemption per MGL c. 14.[:]Other
152,61(4),and we have no employees.[No workers'comp.insurance required.]
'Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information.
t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such.
=Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have
employees. If the sub-contractors have employees,they must provide their workers'comp.policy number.
am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site
information.
Insurance Company Name:HARTFORD FIRE INSURANCE COMPANY
Policy#or Self-ins.Lic.#:08 WEC AE5JE5 Expiration Date:31 DEC 2020
Job Site Address:2 CONZ STREET City/State/Zip:Northampton MA
Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date).
Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00
and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a
day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance
coverage verification.
I do hereby certify
er,under the pains and penalties of perjury that the information provided above is true and correct.
Signature: Date: �l mkM Zdl U
Phone#:413.824.2204
Official use only. Do not write in this vire a,to be completer/by cite or town official.
City or Town: Permit/License#
Issuing Authority(circle one):
1. Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector
6.Other
Contact Person: Phone#:
7 C`t)Nf.4't 1IFNIPES-1 BP-202G-0818
GIs COMMONWEALTH OF 1 S,—;A - t S __ T
Niap.13lock: 2C -06 71 C1TV OF NORT11 N11'' `t.)'
I:ot:-001 Ptah`-SONS WITH UNRI•AiIS f RLDCO TRA TO
Permit: _ Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGA. c.142i'-
Cate r ,AI I ERATION RUI L D I N iJ P.i.:.r RM I.T
Permit,', BP-2020-0818
Protect �r JS.,2020-001412
I=,st=,st. Cost S,1 0000.00
Feu: 52170.00 PERMISSION IS HEREBY GRANTED TO:
(omst. C ki",� Corrtrtretor: License:
Jse GK_up. BRIAN MCSWEENEY Ill 0697333
t,w Size(scl. ft.): 30666.24 ((1witer: NOR I'll f MF]QN 1,;N'l FRPRISFS INC
Z,c�nit, ; t'tE tit > Applrcaut: BRIAN MCSWEENEY III
-ter
Applierrrrt Address: Phone: Insurrrrrc e:
4 FURNARI FARJNI 1 ANI F, .___ __ f>I i� �> -I488
ANDOVERMA01810 _ ISSUED 0,1V:3/13/2020 0:00:00
TO PERFORM THE FOLLOWING WORK:EXPANSION & RENO OF EXISTING SPACE
POST TIIIS CARD SO IT tS VISIBLE FROM THE STRE L"T
Inspector of Plumbing Inspector of Wiring DJI.w. Suitriina inspector
Underground: Service: Meter: �
Footings: - 2
Rough: Rough: House 4 Foundation:
Driveway Final:
Final: Final:
Rough Frame:
(,as: Fire DeCaartolen Fireplace/Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT NIAV BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Certificate of Occupancy. Sinatnrt::
Fee h pe• hate Paid: Amount:
Building 3/13/2020 0:0W00 S2I70.00
,12 Niain Street,Phone W-1)587-12-10. Fa,v (41-33)?87-1272
Louis Fiashrouvk—Buildim-, ( ollintissir�ner
rw weea ccx,IMNY
SUBMITTAL DATA
Order #: Date: 05/14/2020
Project: Hempest Dispensary Northampton
Project #:
Submitter: Jeff Baird
F W WEBB COMPANY
145 Performance Boulevard,
Springfield, Massachusetts 01104
413-781-1700
Information is subject to change without notice.Check local codes. Printed 05/14/2020
Date
05/14/2020
Project Name
Hempest Dispensary Northampton
Project Number FA%' `BB((W h`N)
Client/Purchaser
Submittal Summary Page
Qty Tag# Model# Description
1 CU-1 YCD24B23S York Brand, 2 Ton, Air Conditioner, R-41 OA Refrigerant, 13 SEER/
1-Stage, 208/230-1-60
1 GFU-1 TM9E040A10MP12 Mid Tier, 95%AFUE, Single Stage Gas Valve, X13 ECM Motor, 40
MBH, 14.5"Width Cabinet, 1000 CFM Nominal, Multi-Position, 115-
1-60
1 GFU-1 CF24AXAl 2 Ton, Full Case, Upflow/Downflow, Coil, 14.5" Cabinet Width,
MaxAlloy Flex Coils, Aluminum Tube
1 GFU-1 S1-1TVMBH1 KITTXV,R-410A,3/4 INCH,CHATLEFF CO
Equipment start-up and commissioning by a factory trained technician is recommended.
Contact your supplying distributor or sales representative for additional information &guidance.
WARNING:Cancer and Reproductive Harm-www.P65Warnings.ca.gov
Information is subject to change without notice.Check local codes. Printed 05/14/2020
YORKResidential Split Page:3
WSplit-System Outdoor
Project Name: Hempest Dispensary Northampton Unit Model#: YCD24623S
Quantity: 1 Tag#:CU-1 System: YCD24B23S,TM9E040A1oMP12,CF24AXA1
Cooling PerformanceIII�IIII
Total net capacity25.3 MBH
�
Sensible net capacity 19.1 MBH
Seasonal Efficiency(at ARI) 13.50 SEER - "a• r
Efficiency(at ARI) 11.50 EER
Ambient DB temp. 95.0 °F -Zll
Power input 2.27 kW v _ "
Refrigerant �= i
ZZ
Refrigerant type R-41 OA
Electrical Data
Power supply 208/230-1-60
Unit min circuit ampacity 11.4 Amps
Unit max over-current protection 15 Ams
Dimensions&Weight
Hgt 26.8 in. Len 24 in. Wth 24 in.
Weight with factory installed options 115 lbs.
Matchup Information
ARI Reference Number 204327588
ARI Rated Capacity 25.3 MBH 2 Ton
RI Rated Efficiency 13.5 SEER
Note: Please refer to the tech guide for listed maximum static pressures Unit Features
lllln ® • 13 SEER/1-Stage
}.p ;I, n aur"r" �e saodtnq -' • Environmentally Friendly-CFC-free R-41 OA refrigerant delivers
environmentally friendly performance with zero ozone depletion.
• Durable Finish—The coated steel wire fan guard,coated external fasteners,
and pre-treated G90-equivalent galvanized steel chassis components resist
corrosion and rust creep.Champagne colored powdercoat paint further
protects external panels.
• Fully Exposed Refrigerant Connections and a Single Panel Covering the
Electrical Controls Make for Easy Servicing of the Unit
• Rotary Compressor
• Each Compressor is Protected Against Abnormal Pressures by an Internal
Pressure Relief Valve and Factory Installed High Pressure Switch
• Liquid Line Filter Drier
• Quality Coils-Enhanced aluminum fins are mechanically bonded to copper
tubing.
• Secured Re-Usable Service Valves are Provided on Both the Liquid and
Vapor Sweat Connections for Ease of Evacuating and Charging
• Internally Protected Condenser Fan Motor
Warranty
• Five(5)Year Limited Parts Warranty
• Ten(10)Year Limited Compressor Warranty
• Extended Ten(10)Year Limited Parts Warranty when Product is Registered
Online Within 90 Days of Purchase for Replacement or Closing for New
Home Construction
Information is subject to change without notice.Check local codes. Printed 05/14/2020
YtJRK® Residential Split Page:4
Split-System Outdoor
Project Name: Hempest Dispensary Northampton Unit Model#: YCD241323S
Quantity: 1 Tag#:CU-1 System: YCD24B23S,TM9E040A10MP12,CF24AXA1
Factory installed Options
YCD24B23S
Equipment Options Option(s) Selected
Product Category: Y York Brand
Type: C Air Conditioner
Nominal Series Efficiency&s Staging: D 13 SEER! 1-Stage
Nominal Cooling Capacity: 24 2 Ton
Refrigerant: B R-410A Refrigerant
Voltage: 2 208/230-1-60
k.
Product Generation: 3
Factory-Installed Options: S
Field Installed Accessories
O S1-1 HK0401 -Anchor Bracket Kit O S1-HPRKIT-6-Support Feet
(1.0 lbs) (Snow Feet) Kit-6" (3.5 lbs)
O S1-1HK0601 - Hurricane Kit(LX O S1-THXU280B-Wi-Fi
Series) (1.4 lbs) Communicating Touchscreen
O S1-2FD06700224- Blower-Off Thermostat with Proprietary
Delay(2.0 lbs) Hexagon Interface (Black), with
O S1-2LA04701024 -Advanced Low 2.8"display screen (1.0 lbs)
Ambient Control Kit(1.8 lbs) O S1-THXU280W-Wi-Fi
O S1-2LA06700424 -Standard Low Communicating Touchscreen
Ambient Control Kit(0.8 lbs) Thermostat with Proprietary
O S 1-2 PS06700524- Low Pressure Hexagon Interface (White), with
Switch Kit(R-410A) (0.2 lbs) 2.8"display screen (1.0 lbs)
O S1-2TD08700124BK-5 Minute O S1-THXU430W-Wi-Fi
Time Delay(2.0 lbs) Communicating Touchscreen
O S1-33102952310-Outdoor Thermostat with Proprietary
Communicating Board Kit(2.0 lbs) Hexagon Interface (White), with
O S1-51301535000-Touch-up 4.3"display screen (0.9 lbs)
Paint: Champagne (1.1 lbs)
O S1-51301537000-Touch-up
Paint: Black(1.1 lbs)
O S1-ACB-30 -Wall Mount Kit-30"
(11.3 lbs)
O S1-CCVREA26-Winter Cover Kit,
24"x 24"x 26" Height(6.2 lbs)
O S1-CE-9722- High Ambient
Condenser Fan Motor(1/12- 1/8
HP) (13.0 lbs)
O S1-CHGTENT01 -Cold Weather
Charging Tent(20.0 lbs)
O S1-HPRKIT-12- Support Feet
(Snow Feet) Kit- 12" (6.0 lbs)
O S1-HPRKIT-3 -Support Feet
(Snow Feet) Kit-3" (2.5 lbs)
Information is subject to change without notice.Check local codes. Printed 05/14/2020
MYORK0 Residential Split Page:5
Split-System Outdoor
Project Name: Hempest Dispensary Unit Model M YCD24B23S
Northampton
Quantity: 1 Tag#:CU-1 System: YCD24B23S,TM9E040A10MP12,CF24AXA1
Typical Installation
TYPICAL INSTALLATION
48'OVERHEAD LEARANCE NEC CLASS t WIRING NOTE:
Ensure adequate
wall support
WEATHERPROOF —J
DISCONNECT THERMOSTAT
SWITCH
NEC CLASS 2 WIRING
80"CLEARANCE
Do not locate 3 BRACES
outdoor unit closer Use for wall mount Meth
than the indicated center brace under
clearance to a dryer center of compressor.
vent or to a 90+96 l TO FURNACE OR '1
AIR HANDLER
furnace flue. TERMINAL BLOCK
\ NEC CLASS 2 WIRING '
10-CLEARANCE r
AROUND PERIMETER
(6"clearance
permissible on one
side only.see All outdoor wiring
Alternative must be weatherproof.
Installation
Clearances.)
NOTE CONTROL
ACCESS SEAL OPENINGS 5 SNOW PUMP-UPS
Ensure a minimum of PANEL Use permagum or equivalent. Use in deep snow areas
24"clearance between with fifth pump-up under
any two units. MINIMUM 18'SERVICE ACCESS CLEARANCE center of compressor.
Maintain minimum clearance on one side of access panel.
A CAUTION
Care must be taken to prevent ice frorn damaging the unit.Damage may occur from ice tailing onto unrt from a sloped roof or from a vertical drip
fine due to a partial overhang.
NO OVERHANG COVERING UNIT OVERHANG COMPLETELY
COVERING UNIT OVERHANG PARTIALLY
i COVERING UNIT
1
— 48'MINIMUM
OVERHEAD
CLEARANCE
EARANCE
INSTALLATION ACCEPTABLE INSTALLATION ACCEPTABLE INSTALLATION NOT RECOMMENDED
(Refer to CAUTION above.) (Refer to CAUTION above.)
NOTE: NOTE:
The unit must be installed on a solid base above the grade. Install unit on flat surface.If installation surface is sloped,ensure
The base must not be able to settle or shift causing strain on that unit slopes away from house structure at 114"per foot.
refrigerant lines and possible leaks
CAUTION:
Special care must be taken to avoid recirculation of discharge air through condenser coil.
Information is subject to change without notice.Check local codes. Printed 05/1412020
IS YO R K® Residential Split Page:6
Split-System Outdoor
Project Name: Hempest Dispensary Unit Model#: YCD24B23S
Northampton
Quantity: 1 Tag#:CU-1 System: YCD24B23S,TM9E040A10MP12,CF24AXA1
Unit Dimensions
B
DIMENSIONS
Dimensions Refrigerant Connection
Unit (Inches) Service Valve Size
Model
A I B C Liquid I Vapor
YCD18B21(H,S) 23-1/21 24 24
YCD24B21(H,S) 26-3/4 24 24 314
YCD301321(H,S) 30 24 24
YCD36B21(H,S) 33-1/4 24 24 318
YCD42B21(H,S) 26-3/4 29-1/4 29-1/4 7/8
YCD48B21S 30 29-114 29-1/4
YCD60B21S 36-114129-1/4 29-114 7l8$
$Adapter fitting must be field installed for the required 1-1/8"fine set.
All dimensions are in inches and are subject to change without notice.
Overall height is from bottom of base pan to top of fan guard.
Overall length and width include screw heads.
Information is subject to change without notice.Check local codes. Printed 05/14/2020
ww"YtJRK® Residential Split Page:8
Split-System Outdoor
Project Name: Hempest Dispensary Unit Model#: YCD24B23S
Northampton
Quantity: 1 Tag#:CU-1 System: YCD24B23S,TM9E040A10MP12,CF24AXA1
Typical Wiring
TYPICAL FIELD WIRING
ALL FIELD WIRING TO BE IN AC'C)RDANCF..WITH ELECTRIC CODE(NEC) AND/OR LOCAL CODES
POWER WIRING — — — — POWER WIRING
24 VOLT CONTROL WIRING ————_
208;730-1-60 —— CONTROL.WIRING
�......_ /�_.� MINIMUM 18 GA.WIRE,
(NEC CLASS 2) I FACTORY WIRING
FURNACE OR AIR HANDLER TERMINAL BLACK
trG W !
�•~ — �` I // I I I I •TIiRMINAL W 15 ONLY
t -% •'�„_i i [ I I I REd)URED ON SYSTEMS
CONTACTOR I I ( I I WITH HEAT.
TERMINALS
GND. �...,.,, i
1 1 I
LUG COIL
R\ \`1
� 1 G u
CONDENSING UNIT ROOM THERMOSTAT
I.................................................................................................................._.................................................................__.................................................._.._._....................— .__.._.........................................................;
ALL OUTDOOR WIRING MUST BE WEATHERPROOF, USE COPPER CONDUCTORS ONLY.
ALTERNATIVE INSTALLATION CLEARANCES
MININ1UA1 CLEARANCE BETWLE'NLNI rs
....
. ........................
4AA. .........
.�.i I .J
1
NOTE:
SI%RVK'Ti
SERVICE SE•I[VICB Cls n ix-tw • twounits m hL
i reduced to IS"minimum provided
YM
1
....... ...............Ir^:'....! the service accwss clearance is
{ increased to 24"minimuim and the
IR- clearnce on each remuining side
I ,
UNIT. liNrr• j is maintaincd at lA"minimtnn.
ik" IA" IA'
NOTL:
(`karancemoixside ofthe mvr,i;;ati f t:1r+-�sct renalw-�Lt.
unit may be reduced to ti"provided
the deamtxro to each remaining sick - -�- 1 J!.
is increased to 12"minimum,the 6 is 6
u7v iev acty"is im.reaw.d w 24" i f
minimum,and the clearances between WALL
any two unit,is nummained at 24"
SBRVICI's L�---�
minimum. 24' I ANDUNIT-
SERVICE � T(t.IJNIT
CAUTION:
Special care must be taken to avoid recirculation of discharge air through condenser coil.
Information is subject to change without notice.Check local codes. Printed 05/14/2020
or'YORK"
Residential Split Page:9
Split-System Indoor
Project Name: Hempest Dispensary Northampton Unit Model#: TM9E040A10MP12
Quantity: 1 Tag#:GFU-1 System: YCD24B23S,TM9E040A10MP12,CF24AXA1
Cooling Performance
Total net capacity 25.3 MBH
Sensible net capacity 19.1 MBH
Entering DB temp. 80.0 °F
Entering WB temp. 67.0 °F
Leaving DB temp. 62.0 °F
Leaving WB temp. 59.0 °F
Heating Performance
Entering DB temp. 60 °F
Heating output capacity(Max) 38 MBH '
Supply air 984 CFM
Heating input capacity(Max) 40 MBH j
Leaving DB temp. 95.8 °F
Air temp.rise 35.8 °F
AFUE 95.0 %
Supply Air Blower Performance
Supply air 984 CFM
Ext.static pressure 0.6 IWG
Blower speed description HIGH Unit Features
Motor rating 0.50 HP • Unit Cabinet Constructed of Pre-Painted Steel
Elevation 0 ft. . Sharp Edges Have Been Eliminated by Folding and Flattening the Sheet
Drive type DIRECT Metal
Indoor Electrical Data 60 • Full-Gasket,Rigid Independent Access Doors With View Ports and 1/4 Turn
Power supply - - Knobs
Unit max over-currentrentprotection 15 Amps Unit min circuit a y 10.40 Amps . Units are factory shipped for installation in upflow or horizontal applications
Indoor Dimensions&Weight and may be converted for downflow applications.
• Hi-tech Tubular Aluminized Steel Primary Heat Exchanger with Stainless
Hgt 33 in. Len 29.5 in. Wth 14.5 in. Steel Tube/Aluminum Fin Secondary Heat Exchanger for Outstanding
Weight with factory installed options 113 lbs.
Matchu Information Efficiency.
• Propane Convertible
ARI Reference Number 204327588 Slide-Out Direct Drive Blower with High Efficiency Brushless DC Motor
ARI Rated Capacity 25.3 MBH . Airflow Leakage Rate of Less Than 1%of Total Airflow @ 1"ESP Under
RI Rated Efficiency 13.5 SEER
Note: Please refer to the tech guide for listed maximum static pressures Duct Testing Conditions
• Built-In,High-Level Self-Diagnostic Controls with Fault Codes for Reliable
IIIII� / � AME® Operation
Aw 4!' I ! f noA��N Warranty
Five(5)Year Limited Parts Warranty
A 20-year limited warranty on heat exchangers in residential applications.
q=" A 10-year warranty on heat exchangers in commercial applications.
• Extended lifetime heat exchanger and 10-year limited parts warranty when
product is registered online within 90 days of purchase for replacement or
closing for new home construction.
Information is subject to change without notice.Check local codes. Printed 05/14/2020
YORK® Residential Split Page: 10
1 Split-System Indoor
Project Name: Hempest Dispensary Northampton Unit Model#: TM9E040A10MP12
Quantity: 1 Tag#:GFU-1 System: YCD24B23S,TM9E040A10MP12,CF24AXA7
Factory Installed_ Options
TWEWA10MP12
Equipment Options Option(s) Selected
RR
Brand: T
3
Tier: M Mid Tier
Efficiency: 9 95%AFUE
Type: E Single Stage Gas Valve,X13 ECM Motor
' BTU Input: 040 40 MBH
Cabinet Width: A 14.5'Width Cabinet
Airflow: 10 1000 CFM Nominal
Configuration: MP Multi-Position
J- Voltage:1 115-1-60laffifflolliffim
Product Generation: 2
Field Installed Accessories
O S1-1BR0514-Bottom Return O S1-1NP0820- Propane (LP)
Filter Rack Galvanized (Fits 14.5' Conversion Kit- includes stainless
wide furnace) (8.0 lbs) steel LP Burners (3.0 lbs)
O S1-1BR0614- Bottom Return O S1-1PS3307- High Altitude Kit
Filter Rack(1"—4") Pre-Painted (0.2 lbs)
To Match Furnace (Filters are O S1-1SR0200- Side Return Filter
NOT included with the kit) (14.0 Rack 16x25x2 Contains 2" Hi-
lbs) Velocity Pleated Filter(RNC or
O S1-1CB0514- Combustible Floor AOR) (11.0 lbs)
Base (For Downflow Applications) O S1-1SR0402- Side Return Filter
(5.9 lbs) Rack 16x25x2 Contains 1"
O S1-1CT0302-Concentric Vent Aluminum Mesh Filter(RNC or
Termination Kit—2" (6.0 lbs) AOR) (4.5 lbs)
O S1-1CT0302-636-Concentric O S1-2HU16700124- Humidistat
Vent Termination Kit—2" (Canada) (5.0 lbs)
(6.0 lbs) O S1-32924441000 - Natural (NAT)
O S1-1CT0303-Concentric Vent Gas Stainless Steel Burner Kit
Termination Kit-3"(9.0 lbs) (3.0 lbs)
O S 1-1 CT0303-636-Concentric O S1-37327901001 -York Affinity
Vent Termination Kit-3" (Canada) Cladding Kit(2.3 lbs)
(9.0 lbs)
O S1-1HT0901 -Sidewall Vent
Termination Kit—3" (1.5 lbs)
O S1-1HT0902-Sidewall Vent
Termination Kit—2" (2.0 lbs)
O S1-1NK0301 -Condensate
Neutralizer Kit(3.0 lbs)
O S1-1NP0347- Propane (LP)
Conversion Kit(0.6 lbs)
Information is subject to change without notice.Check local codes. Printed 05/14/2020
YtJRK® Residential Split Page: 11
or' Split-System Indoor
Project Name: Hempest Dispensary Unit Model#: TM9E040A10MP12
Northampton
Quantity: 1 Tag*GFU-1 System: YCD24B23S,TM9E040A10MP12,CF24AXA1
Dimensions&Clearances
LEFT SIDE FRONT RIGHT SIDE
Combustion Air inlet Combustion Air Inlet
_ ...._._.._. ...... .......
Condensate Drain' Gas Pipe
(Downflow) Entry Gas PipeCondensate Drain
Entry (Downflow)
Vent Outlet—! Electrical
Entry Electrical
O Entry Vento tlet
Condensate
Drain ® (D 33 Condensate 1.bo 23- T
r t ® (D Drain r t
Thermostat
Wiring Thermostat
Wiring Optional Return Air
Cutout(Either side) 14"
i"
29p5" — N A 1.5" 4- I
.56"
�..
43ent
W --
Outlet
B Combustion B
Air Inlet
56 56" 20" — —►) �— 24.25"
SUPPLY END RETURN END
Cabinet&Duct Dimensions
BTUH(kW) Nominal Cabinet Cabinet Dimensions(Inches) Approximate
Operating Weights
Input CFM{m31min} Size A B C Lbs
TM9E040A10MP11 1000 A 14-112 13-3/8 11-3/4 113
TM9E060B12MP11 1200 B 17-1/2 16-3/8 13-1/4 122
TM9E080B12MP11 1200 B 17-1/2 16-3/8 14-3/4 126
TM9E080C16MP11 1600 C 21 19-7/8 16-1/2 136
TM9E100C16MP11 1600 C 21 19-7/8 18-1/4 142
TM9E100C20MP11 2000 C 21 19-7/8 18-1/4 145
TM9E120020MP11 2000 D 24-1/2 23-3/8 21-3/4 156
Ratings&Physical I Electrical Data
Nominal Air Temp. Max.Outlet Max Min.wire Size
BTUH(kW) Output AFUE Blower Blower Total Unit
Input Airflow Rise Air Temp Size Over-Current Am (awg)@ 75 ft
p MBH CFM % °F °F HP Amps Protect Amps one way
TM9E040A10MP11 38 1000 95.0 45-75 180 1/2 6.8 11x8 15 9.5 14
TM9E060B12MP11 57 1200 95.0 40-70 180 1/2 6.8 11x8 15 9.5 14
TM9E080B12MP11 76 1200 95.0 50-80 170 1/2 6.8 11x8 15 9.5 14
TM9E080C16MP11 76 1600 95.0 40-70 165 1/2 6.8 1100 15 9.5 14
TM9E100C16MP11 95 1600 95.0 45-75 170 1/2 6.8 1100 15 9.5 14
TM9E100C20MP11 95 2000 95.0 50-80 165 3/4 8.4 1101 15 10.9 14
TM9E120D20MP11 114 2000 95.0 50-80 175 3/4 8.4 11x11 15 10.9 14
NOTES:
Annual Fuel Utilization Efficiency(AFUE)numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code(NFPA-70-latest edition)and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
Information is subject to change without notice.Check local codes. Printed 05/14/2020
YORK® Residential Split Page: 12
Split-System Coil
Project Name: Hempest Dispensary Northampton Unit Model#: CF24AXAl
Quantity: 1 Tag*GFU-1 System: YCD24B23S,TM9E040A10MP12,CF24AXA1
Cooling Performance
Total gross capacity 25.3 MBH
Sensible gross capacity 19.1 MBH
Ambient DB temp. 95.0 °F
Refrigerant
Refrigerant type R-41 OA
Coil Dimensions&Weight
Hgt 19.5 in. Len 21.5 in. Wth 14.5 in.
Weight with factory installed options 40 lbs.
Matchup Information
ARI Reference Number 204327588
ARI Rated Capacity 25.3 MBH
ARI Rated Efficiency 13.5 SEER
Wetering Device S1-1TVMBH1 (or equiv
Note: Please refer to the tech guide for listed maximum static pressures &
I�Irllll II III IIII�I��I AMAM®V
i I I GUAl1TY �P� (\Ge�Od"Hd�6'0'keepktg ��
Unit Features
• CF Series is Upflow/Downflow Only Application.If Removed from Case,will
Need Diverter Available on Accessory Page
• Copper Sweat Connect Fittings
• Aluminum Tube/Aluminum Fin Coil
• Rigid Case Construction Interior Endoskeleton for Structural Support,Flush
Side,and Locks in Insulation
• G30 Galvanized Steel Case
• Long Life Aluminum Coils
• Quality Aluminum or G90 Galvanized Steel Construction
• Foil Faced Improved Insulation Design
• Bolt-on-TXV Provides Easy Installation;Some Models Are Available with
Factory Installed TXV
• 20.5'Casing for Easy Attic Access
• Thermal Plastic Drain Pan
Warranty
• Five(5)Year Limited Parts Warranty
• Ten(10)Years Extended Limited Parts Warranty(with Registration)
Information is subject to change without notice.Check local codes. Printed 05/14/2020
� ® Residential Split Page: 13
YO RK
Split-System Coil
Project Name: Hempest Dispensary Northampton Unit Model#: CF24AXAl
Quantity: 1 Tag#:GFU-1 System: YCD24B23S,TM9E040A10MP12,CF24AXA1
Factory Installed Options
CF24AXA1
Equipment Options Option(s) Selected
4 Product Type: C Coil
Product Category: F Full Case, Upflow/Downflow
Capacity: 24 2 Ton
Cabinet Width: A 14.5'Cabinet Width
Refrigerant/TXV: X MaxAlloy Flex Coils
Coil Options: A Aluminum Tube
Product Generation:
Field Installed Accessories
• S1-1TVMBH1 - KIT,TXV,R-
410A,3/4 INCH,CHATLEFF CO
(1.2 lbs)
Information is subject to change without notice.Check local codes. Printed 05/1412020
a, Residential Split Page: 14
YORK Split-System Coil
Project Name: Hempest Dispensary Unit Model M CF24AXAl
Northampton
Quantity: 1 Tag#:GFU-1 System: YCD24B23S,TM9E040A10MP12,CF24AXA1
CF Coil Dimensions
DIMENSIONS CF
Dimensions 2
Refrigerant
Connections 3.4.5
19-ve - - Models'
(OWNING) `�-`-C(OPENING) Height Width Opening Widths Line Size
A 8 C D Liquid Vapor
CF18A'A 1 19-112 14-112 13-1/2 13-1/2
CF18BXAl 19 17-1/2 16-1/2 16-1/2
CF24A'A1 19-1/2 14-1/2 13-1/2 13-1/2
I. CF24BXA1 19 17-1/2 1 16-1/2 16-1/2
A CF24CXAl 21 21 20 20
CF30AXA 1 21-5/8 14-1/2 13-1/2 13-1/2
CF30B'A1 23 17-1/2 16-112 16-1/2 3/4
CF30CXAl 21 21 20 20
CF30OXAl 25 24/112 23-112 23-1/2
C F36AXA 1 25-1/2 14-1/2 13-1/2 13-1/2
CF36B'A1 25-5/8 17-1/2 16-1/2 16-1/2 3/8
20 V2°
B ( , � CF36CXA1 23 21 20 20
21-112" CF36DXA1 25 24-1/2 23-1/2 23-1/2
CF426XAl 25 17-1/2 16-1/2 16-112
CF42C'A1 25 21 20 20
CF42DXAl 25 24-1/2 23-1/2 23-1/2
BOTTOM OPENING CF48C"A1 27 21 20 20
DIMENSIONS 7/8
14.118„ CF48DXA1 27 24-1/2 23-1/2 23-1/2
D(OPENING; / CF60C"A1 33 21 20 20
��'!s1 `4` CF60DXAl 32-3/4 24-1/2 23-1/2 23-1/2
CF64DXA1 32-3/4 24-1/2 23-1/2 23-1/2
1.Asterisk(')denotes coil model is available as a flex coil or with factory installed TXV.
2. All dimensions are in inches.
3. Refrigerant line sizes may require larger lines for extended line lengths.See Application Data part number 247077.
4.Adapter fitting must be field installed for other line set size.
5. See outdoor unit technical guide for proper line set size.
DIMENSIONS CM
`-�
, � c Connections3,4
Dimensions ,5ts1/8„ 2 Refrigerant
G ' ,
(OPENIPENING)
Models
Height Width Opening Widths Line Size
A B C D Liquid Vapor
CM18A'A1 19-1/2 14-1/2 13-1/2 13-1/2
CM18BXAl 19 17-1/2 16-1/2 16-1/2
CM24A'A 1 19-112 14-1/2 13-1 J2 13-112
A CM 24B'A 1 19 17-1/2 16-1/2 16-1/2
CM24CXAl 21 21 20 20
CM 30A'A 1 25-1/2 14-1/2 13-1/2 1 13-112
CM30B"A1 23 17-1/2 16-1/2 16-112 314
CM30CXA1 23 21 20 20
L CM30DXA1 25 24/112 23-1/2 23-112
CM36AXA l 25-1/2 14-1/2 13-112 13-1/2
CM36B'A1 25-5/8 17-1/2 16-1/2 16-1/2 3!8
21-112„ CM36C'A1 25 21 20 20
CM36DXAl 25 24-112 23-1/2 23-1/2
CM42C'A1 27 21 20 20
CM42DXAl 27 24-1/2 23-112 23-1/2
BOTTOM OPENING CM48C"A1 33 21 20 1 20
DIMENSIONS CM480'A1 32-3/4 24-1/2 23-1/2 23-112 7/8
19'1'9' CM60C"A1 33 21 20 20
D(OPENING) CM60D-A1 32-3/4 24-1/2 1 23-112 23-1/2
Ap9Y:1-991
CM64DXAl 32-3/4 24-112 1 23-112 23-112
1. Asterisk(')denotes coil model is available as a flex coil or with factory installed TXV.
2. All dimensions are in inches.
3. Refrigerant line sizes may require larger lines for extended line lengths.See Application Data part number 247077.
4.Adapter fitting must be field installed for other line set size.
5. See outdoor unit technical guide for proper line set size.
Johnson Controls Unitary Products 3
Information is subject to change without notice.Check local codes. Printed 05/14/2020
...............
F- BATH
IF F20-5 10x10
4WA
----
BREAK
�'OUNTING RM p ROOM
VAULT
F2 0 E
-6 6 f-2-04
F207 4 Y 8X8
RE5.
8X8
4WAYrF�nFE
18X8 ,
4WAY 6" 6''
101, 12" Pi I
rl
12" -----------
14'' ----------
OFFICE - ---------
F
-3] ----------
203
6X
R ...........
6X6PACKAGING 8X8
RE51� F-2-0-2-] 4WAY
23
wrightsoft Load Short Form Jo Date: May 1342020
Entire House By: Jeff B
NOLAN PLUMBING AND HEATING
Project Information
For: HEMPEST DISPENSARY
20 CONZ ST, NORTHAMPTON, MA
Design Information
Htg Clg Infiltration
Outside db(°F) -5 97 Method Simplified
Inside db(°F) 70 75 Construction quality Semi-tight
Design TD(°F) 65 22 Fireplaces 0
Daily range - M
Inside humidity(%) 50 50
Moisture difference(gr/Ib) 49 42
HEATING EQUIPMENT COOLING EQUIPMENT
Make n/a Make n/a
Trade n/a Trade n/a
Model n/a Cond n/a
AHRI ref n/a Coil n/a
AHRI ref n/a
Efficiency n/a Efficiency n/a
Heating input Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 °F Total cooling 0 Btuh
Actual air flow 0 cfm Actual air flow 0 cfm
Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat n/a Load sensible heat ratio 0
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ftZ) (Btuh) (Btuh) (cfm) (cfm)
SECOND FL. SYSTEM 960 18615 18057 889 889
FIRST FL. SYSTEM 1231 22211 21930 1085 1085
Entire House 2191 40826 39744 1974 1974
Other equip loads 0 0
Equip. @ 1.02 RSM 40539
Latent cooling 10681
TOTALS I 2191 I 40826 I 51220 I 1974 I 1974
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-May-13 08:19:49
wrightSOft" Right-Suite(g)Universal 2017 17.0.28 RSU18116 Page 1
PR.i ...cumenls\Wrightsoft HVAC\HEMPEST-NORTHAMPTON.rup Calc=MJ8 Front Door faces: N
Load Short Form Job: RT-678423
Wry tso ,
Date: May 13,2020
FIRST FL. SYSTEM By: Jeff B
NOLAN PLUMBING AND HEATING
Project • -
For: HEMPEST DISPENSARY
20 CONZ ST, NORTHAMPTON, MA
Design Information
Htg Clg Infiltration
Outside db(°F) -5 97 Method Simplified
Inside db(°F) 70 75 Construction quality Semi-tight
Design TD(°F) 65 22 Fireplaces 0
Daily range - M
Inside humidity(%) 50 50
Moisture difference(gr/Ib) 49 42
HEATING EQUIPMENT COOLING EQUIPMENT
Make Make
Trade Trade
Model Cond
AHRI ref Coil
AHRI ref
Efficiency Efficiency 0 SEER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 °F Total cooling 0 Btuh
Actual air flow 1085 cfm Actual air flow 1085 cfm
Air flow factor 0.049 cfm/Btuh Air flow factor 0.049 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.80
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ft2) (Btuh) (Btuh) (cfm) (cfm)
SALES FLOOR 883 12680 14803 619 732
ENTRY 233 6431 2408 314 119
SECURITY 115 3100 4719 151 233
FIRST FL. SYSTEM 1231 22211 21930 1085 1085
Other equip loads 0 0
Equip. @ 1.02 RSM 22369
Latent cooling 5644
TOTALS I 1231 I 22211 I 28013 I 1085 I 1085
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-May-13 08:19:49
%_ wrightsbft" Right-Suite®Universal 2017 17.0.28 RSU18116 Page
,'M ...currents\Wrightsoft HVAMHEMPEST-NORTHAMPTON.rup Calc=MJ8 Front Door faces: N
Job: RT-678423
. wrightsoft Load Short Form Date: May 13,2020
SECOND FL. SYSTEM By: Jeff B
NOLAN PLUMBING AND HEATING
Project I • •
For: HEMPEST DISPENSARY
20 CONZ ST, NORTHAMPTON, MA
Design Information
Htg Cig Infiltration
Outside db (°F) -5 97 Method Simplified
Inside db(°F) 70 75 Construction quality Semi-tight
Design TD (°F) 65 22 Fireplaces 0
Daily range - M
Inside humidity(%) 50 50
Moisture difference(gr/Ib) 49 42
HEATING EQUIPMENT COOLING EQUIPMENT
Make Make
Trade Trade
Model Cond
AHRI ref Coil
AHRI ref
Efficiency Efficiency 0 SEER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 °F Total cooling 0 Btuh
Actual air flow 889 cfm Actual air flow 889 cfm
Air flow factor 0.048 cfm/Btuh Air flow factor 0.049 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.78
ROOM NAME Area Htg load Clg load Htg AVF Cig AVF
(ft2) (Btuh) (Btuh) (cfm) (cfm)
VAULT 104 1655 479 79 24
BREAK RM 174 2682 5583 128 235
CORRIDOR 128 230 184 11 9
BATH 60 5122 1760 245 87
COUNTING RM 77 746 1201 36 59
OFFICE 144 2919 3653 139 180
PACKAGING 154 2685 3447 128 170
STAIRS-CLST 120 2576 1749 123 86
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-May-13 08:19:49
►. wrightSOft Right-Suite®Universal 2017 17.0.28 RSU18116 Page
/ + ...currents\Wrightsoft HVAC\HEMPEST-NORTHAMPTON.rup Calc=MJ8 Front Door faces: N
SECOND FL. SYSTEM 960 18615 18057 889 889
Other equip loads 0 0
Equip. @ 1.02 RSM 18418
Latent cooling 5037
TOTALS I 960 I 18615 I 23455 I 889 I 889
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-May-13 08:19:49
►: wrtghtsoft Right-Suite®Universal 2017 17.0.28 RSU1 8116 Page
...cuments\Wrighlsoft HVAMHEMPEST-NORTHAMPTON.rup Calc=MJ8 Front Door faces: N
Building Analysis Job: RT-678423
- I- wrightsoft` gnaDate: May 13,2020
Entire House By: Jeff B
NOLAN PLUMBING AND HEATING
Project Information
For: HEMPEST DISPENSARY
20 CONZ ST, NORTHAMPTON, MA
Desiqn Conditions
Location: Indoor: Heating Cooling
Chicopee Falls/West, MA, US Indoor temperature (°F) 70 75
Elevation: 246 ft Design TD (°F) 65 22
Latitude: 42°N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/Ib) 49.5 41.7
Dry bulb(°F) -5 97 Infiltration:
Dailyrange (°F) - 23 ( M ) Method Simplified
V\kt bulb(°F) - 77 Construction quality Semi-tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
Component Btu h/111 Btuh %of load
Walls 5.6 10302 25.2 Veniiabw
Glazing 37.0 5042 12.4 veils Dx1s
Doors 25.3 1063 2.6
Ceilings 3.5 4863 11.9 kfbatkn
Floors 6.3 7702 18.9
Infiltration 2.9 5788 14.2
Ducts 2527 6.2 0ming
Piping 0 0 Floors
Humidification 0 0 lirx}s
Ventilation 3538 8.7
Adjustments 0
Total 1 40826 100.0
Component Btuh/ft2 Btuh %of load
Walls 1.5 2786 7.0
Glazing 50.1 6826 17.2 V�dlstilaial
Doors 12.5 525 1.3 Gating
Ceilings 3.0 4163 10.5
Floors 0 0 0
Infiltration 0.5 1051 2.6 aha'
Ducts 1064 2.7
Ventilation 1199 3.0 CerifliI71trraig
Irterr>d C�irsInternal gains 22130 55.7Blower 0 0
Adjustments 0 Iso
Total 39744 100.0
Latent Cooling Load= 10681 Btuh
Overall U-value=0.096 Btuh/ftz-°F
Data entries checked.
2020-May-13 08:19:49
wrightsoft' Right-Suite®Universal 2017 17.0.28 RSU18116 Page 1
�^ ...cuments\wrightsoft HVAC\HEMPEST-NORTHAMPTON.rup Calc=MJ8 Front Door faces: N
Building Analysis Job: RT-678423
wriglhtsoft` gnay Date: May 13,2020
FIRST FL. SYSTEM By: Jeff B
NOLAN PLUMBING AND HEATING
Project
For: HEMPEST DISPENSARY
20 CONZ ST, NORTHAMPTON, MA
Design Conditions
Location: Indoor: Heating Cooling
Chicopee Falls/West, MA, US Indoor temperature (°F) 70 75
Elevation: 246 ft Design TD(°F) 65 22
Latitude: 42°N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/Ib) 49.5 41.7
Dry bulb(°F) 5 97 Infiltration:
Dailyrange (°F) - 23 ( M ) Method Simplified
Wet bulb('F) - 77 Construction quality Semi-tight
Wind speed(mph) 15.0 7.5 Fireplaces 0
Component Btuh/ft' Btuh %of load
Walls 5.6 4966 22.4 QJds
Glazing 37.0 1043 4.7 NiIs Infiltration
Doors 25.3 1063 4.8
Ceilings 7.8 3243 14.6
Floors 6.3 7702 34.7 Cawing
Infiltration 2.9 2746 12.4
Ducts 1447 6.5 Doors
Piping 0 0 Floors
Humidification 0 0 Ceilings
Ventilation 0 0
Adjustments 0
Total 22211 100.0
-Component Btuh/fF Btuh % of load
Walls 1.5 1343 6.1 VNIIs
Glazing 73.5 2072 9.5 Gaarg
Doors 12.5 525 2.4 Dtxrs
Ceilings 6.6 2776 12.7
Floors 0 0 0
Infiltration 0.5 499 2.3 Calings
Ducts 615 2.8
Ventilation 0 0 Irfiltrdirns IrteTal Cies
Internal gains 14100 64.3 Dui
Blower 0 0
Adjustments 0
Total 1 219301 100.0
Latent Cooling Load=5644 Btuh
Overall U-value=0.106 Btuh/ft2-°F
WARNING:window to floor area ratio=2.3%-less than 5%.
2020-May-13 08:19:49
'+ W1 ightsoft Right-Suite@ Universal 2017 17.0.28 RSU18116 Page 2
...cuments\Wrightsoft HVAMHEMPEST-NORTHAMPTON.rup Calc=MJ8 Front Door faces: N
Buildin Anal sis Job: RT-678423
wrl htsoft y Date: May 13,2020
SECOND FL. SYSTEM By: Jeff B
NOLAN PLUMBING AND HEATING
Project Information
For: HEMPEST DISPENSARY
20 CONZ ST, NORTHAMPTON, MA
Design Conditions
Location: Indoor: Heating Cooling
Chicopee Falls/West, MA, US Indoor temperature (°F) 70 75
Elevation: 246 ft Design TD (°F) 65 22
Latitude: 42°N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/Ib) 49.5 41.7
Dry bulb(°F) 5 97 Infiltration:
Dailyrange(°F) - 23 ( M ) Method Simplified
Wet bulb(°F) - 77 Construction quality Semi-tight
Wind speed(mph) 15.0 7.5 Fireplaces 0
Component Btuh/ftz Btuh %of load
Walls 5.6 5335 28.7
Glazing 37.0 3999 21.5 Verlblebw
Doors 0 0 0 WAIS
Ceilings 1.7 1620 8.7 [qcls
Floors 0 0 0
Infiltration 2.9 3043 16.3
Ducts 1080 5.8 ���
Piping 0 0
Humidification 0 0 Gazing Ceilings
Ventilation 3538 19.0
Adjustments 0
Total 18615 100.0
—Component Btu h/112 Btuh %of load
Walls 1.5 1443 8.0
Glazing 46.2 4990 27.6 V\13IIs Me tilation
Doors 0 0 0
Ceilings 1.4 1387 7.7
Floors 0 0 0 Gating
Infiltration 0.5 553 3.1
Ducts 456 2.5
Ventilation 1199 6.6 InterrEll Gars
Internal gains 8030 44.5
Blower 0 0 li
Adjustments 0 9r
Total 1 1 18057 100.0 fl Ducts
Latent Cooling Load =5037 Btuh
Overall U-value=0.083 Btuh/ft2-°F
Data entries checked.
, � �,� ,. 2020-May-13 08:19:49
Right-SuileOUniversal 2017 17.0.28 RSU18116 Page
+ ...cuments\Wrighlsofl HVAMHEMPEST-NORTHAMPTON.rup Calc=MJ8 Front Door faces: N
N
Level 1
HALL
NOT IN SCOP
SALES FLOO
23'-6'
SECURIT`
ENTR)
14-7'4-111�
Job#: RT-678423 NOLAN PLUMBING AND HEATING Scale: 1 : 88
Performed by Jeff B for: Page 1
HEMPEST DISPENSARY Right-Su ite®Universal 201 7
20 CONZ ST
NORTHAMPTON,MA 17.0.28 811
2020-May--11 3 3 08:20:30 30
...oft HVAMHEMPEST-NORTHAMPTON.
N
SECOND FLOOR
BATH
BREAK RA
VAULT COUNTING RI
CORRIDOF
OFFIC' STAIRS-CLS
PACKAGING
Job#: RT-678423 NOLAN PLUMBING AND HEATING Scale: 1 : 88
Performed by Jeff B for: Page 2
HEMPEST DISPENSARY Right-Suite®Universal 2017
20 CONZ ST
NORTHAMPTON,MA 17.0.28 811
2020-May--113 3 08:20:30 30
...oft HVAC\HEMPEST-NORTHAMPTON.