44 HERS DIAL_SELF Apt 204 - Dial Self Apartment 204Home Energy Rating Certificate Rating Date: 2020-01-22 HIS
Final Report Registry I D: 845843611 HERS
Ekotrope ID: ILXggr92
Your Home's Estimated Energy Use:
Head ng
Cooling
Hot Water
Lights/Appliances
Service Charges
Generation (e.g. Solar)
Total:
Existing
Homes
Reference
Home
Zero Energy
Home
Mon Energy
150
140
L30
L20
110
goo
90
80
70
60
so
00
w This Home
w
10
0
Less Energy
Use [MBtu]
Annual Cost
0.2
$8
0.2
$7
5.1
$235
8.0
$369
Primary Heating System:
$72
0.0
$0
13.4
$692
Horne Feature Summary:
HomeType:
Apartment, end unit
Model:
NIA
Community:
NIA
Conditioned Floor Area:
309 ft'
Number of Bedrooms:
1
Primary Heating System:
Air Source Heat Pump • Electric • 2.93 COP
Primary Cooling System:
Air Source Heat Pump • Electric • 19 SEER
Primary Water Heating:
Water Heater • Electric • 1 Energy Factor
House Tightness:
103 CFM50 [2.50 ACH50]
Ventilation:
18.6 CFM • 4.2 Watts
Duct Leakage to Outside:
Untested
Above Grade Walls:
R-37
Ceiling:
Attic, R-67
Window Type:
U -Value: 0.25, SHGC: 0.29
Foundation Walls:
NIA
This home meets or exceeds the
criteria of the following:
2015 International Energy Conservation Code
Rating Completed by:
Energy Rater.Adin Maynard
RESNETID:9463452
Rating Company:HIS & HERS Energy Efficiency
Mailing: 12 Perkins Ave. Northampton MA 01060
4136588784
Rating ProviderInergy Raters of Massachusetts
2 Woodlawn Street Amesbury, MA 01913
*Ir'
978-270-3911
PL ,
Adin Maynard, Certified Energy Rater
Digitally signed: 1124120 at 2:11 PM
IECC 2015 Label
71 S Hatfield St Apt 204
Ekotrope RATER - Version: 3.2.2.2343
HERS@) Index Score: 44
Building Envelope Specs
Ceiling: R-67
Above Grade Walls: R-37
Foundation Walls: NIA
Exposed Floor: R-19
Slab: null
Infiltration: 103 CFM50 (2.50 ACH50)
Duct Insulation: R-6
Duct Lkg to Outdoors: Untested
Wndow & Door Specs
U-Value: 0.25, SHGC: 0.29
Door: R-5
Mechanical Equipment Spec
Heating: Air Source Heat Pump - Electric - 2.93
COP
Cooling: Air Source Heat Pump - Electric - 19
SEER
Hot Water: Water Heater • Electric • 1 Energy
Factor
Builder or Design Professional
Signature:
Air Leakage Report
Property
11 B Hatfield St Apt 204
Northampton, MA 01060
Dial Self Apartment 204
DIALISELF Apt 204
Organization
HIS & HERS Energy Effie!,
4136588784
Adin Maynard
Builder
Keiter Builders, Inc.
Inspection Status
2020-01-22
Rater ID (RTIN): 9463452
RESNET Registered
(Confirmed)
General Information
Conditioned Floor Area [sq. ft.] 309.2
Infiltration Volume [cu. ft.] 2,473
Number of Bedrooms 1
Air Leakage
Measured Infiltration
103 CFM50 (2.50ACH50)
ACH50 (Calculated)
2.50
ELA [sq. in.] (Calculated)
5.67
ELA per 100 s.f. Shell Area (Calculated)
0.479
CFM50 (Calculated)
103
CFM501 s.f. Shell Area (Calculated)
0.087
Duct Leakage
Leakage to Outdoors
Total Leakage Test Type
Total Leakage [CFM @ 25 Pa]
Total Leakage [CFM251 100 s.f.]
Total Leakage [CFM251 CFA]
Mechanical Ventilation
Rate [C F M]
18.6
Hours per day
24.0
Fan Watts
4.2
Recovery Efficiency %
90.0
Runs at least once every 3 hrs?
true
Average Rate [CFM]
18.6
2010 ASH RAE 62.2 Req. Cont. Ventilation
18.1
2013 ASHRAE 62.2 Req. Cont. Ventilation
24.3
Ekotrope RATER - Version 3.2.2.2343
All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report.
HERS
RESNET HOME ENERGY HIS
RATING Standard Disclosure HERS
For home(s) located at: 11 B Hatfield St Apt 204,
Northampton, AAA
Check the applicable disclosure(s) in accordance with the instructions on the reverse of this page:
"1. The Rater or the Rater's employer is receiving a fee for providing the rating on this home
a 2. In addition to the rating, the Rater or the Rater's employer has also provided the following consulting services
for this home:
EIA. Mechanical system design
E[ B. Moisture control or indoor air quality consulting
EIC. Performance testing and/or commissioning other than required for the rating itself
E[ D. Training for sales or construction personnel
E[ E. Other(specify)
E]3. The Rater or the Rater's employer is:
E]A. The seller of this home or their agent
E[ B. The mortgagor for some portion of the financed payments on this home
E]C. An employee, contractor, or consultant of the electric and/or natural gas utility serving this home
E]4. The Rater or Rater's employer is a supplier or installer of products, which may include:
Products
HVAC systems
Installed in this home by
LIRater []Employer
OR is in the business of
LjRater E]Eimployer
Thermal insulation systems
Rater
[]Employer
Rater
E]Eimployer
Air sealing of envelope or duct systems
Rater
[]Employer
Rater
E]Eimployer
Energy efficient appliances
Rater
E]Employer
Rater
E]Eimployer
Construction (builder, developer, construction contractor, etc)
Rater
[]Employer
Rater
[]Eimployer
Other (specify): E---- --I
Rater
Employer
EIRater
E]Eimployer
5. This home has been verified under the provisions of Chapter 6, Section 603 "Technical Requirements for
Sampling" of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy
Services Network (RESNET). Rater Certification #: 9463452
Name: Adin Maynard Signature:
Organization: HIS & HERS Energy Efficiency Digitally signed: 1124120 at 2:11 PM
I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating
Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating
Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality
control provisions of the rating standard are contained inChapter One 4.C.8. of the standard and are posted at
http://resnet. u slsta nd a rdsIR ES N ET_Mortgage_industry_N ati ona I_H E RS_Sta n d a rd s. pdf
The Home Energy Rating Standard Disclosure for this home is available from the rating provider.
RESNET Form 03001-2 -Amended April 24, 2007