17A-064 (4) 257 BRIDGE RD SM-2020-0015 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON GIS#: 1374 Map: 17A !; Block. 064 Lot: o01 SHEETMETAL PERMIT � Permit: SHEETMETAL Category: renovation Permit# SM-2020-0015 PERMISSION IS HEREBY GRANTED TO: Project# JS-2020-000694 Est.Cost: $12,000.00 Contractor: License: Expires: Fee Charged:$50.00 ROCK VALLEY HVAC Sheetmetal-2626 04/28/2020 Balance Due:$.00 Owner: NORWICH PROPERTIES LLC #of Fixtures:' Applicant: ROCK VALLEY HVAC DigSafe# AT: 257 BRIDGE RD UseGroup I ConstClass ISSUED ON: 31-Oct-2019 AMENDED ON: EXPIRES ON: TO PERFORM THE FOLLOWING WORK: HVAC FOR 1 ST FLOOR THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal REC-2020-001487 30-Oct-19 1251 $50.00 212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:Ihasbrouck(&.northamptonma.gov GeoTMS®2019 Des Lauriers Municipal Solutions,Inc. File#SM-2020-0015 APPLICANT/CONTACT PERSON ROCK VALLEY HVAC ADDRESS/PHONE box 1162 (413)535-7804 PROPERTY LOCATION 257 BRIDGE RD MAP 17A PARCEL 064 001 ZONE URB(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid TypeofConstruction: HVAC FOR 1ST FLOOR New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 2626 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project: Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management " , � %�� — )a 3, Sig ture of Building Official 10 Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact the Office of Planning&Development for more information. Commonwealth of Massachusetts R Sheet Metal Permit VFD Date: 10/22/2019 Permit#,501"'10"/ OCT 3 c / 0 X41 Estimated Job Cost: $12,000 Permit Fee: $ J Q` 9 T�U !n!r!l!c Plans Submitted: YES NO Plans Reviewed: YES NO °" ^41 o soo/Vs Business License #824 Applicant License # SM2626 L5/ Business Information: Property Owner/Job Location Information: Name: Jesse Fortier (Rock Valley HVAC) Name: Kevin Perrier(Norwich Properies) Street: 296C Nonotuck Street Street: 257 Bridge Rd. City/Town: Florence City/'Town: Florence Telephone: (413) 535-7804 Telephone: (413) 246-9845 Photo I.D. required/Copy of Photo I.D. attached: YES NO Staff Initial J-1 /M-1-unrestricted license J-2/M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less Residential: 1-2 family ✓ Multi-family Condo /Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft. ✓ over 10,000 sq. ft. Number of Stori s:2 Sheet metal work to be completed: New Work: Renovation: HVAC ✓ Metal Watershed Roofing Kitchen Exhaust System _ Metal Chimney/Vents Air Balancing Provide detailed description of work to be done: Provide and install complete HVAC system, fabricate and install custom fabricated sheet metal duct system for first floor. All ductwork to be sealed and insulated to energy star standards and installed in conditioned space. All equipment and ductwork sized according to Manual J 8th edition heat load calculation. INSURANCE COVERAGE: I have a current liabili insurance policy or its equivalent which meets the requirements of M.G.L. Ch. 112 Yes XNo ❑ If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy 0 Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. _ Check One Only `—_ Owner Agent ❑ Signature of Owner or Owner's Agent By checking this box•,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of theGener Laws. Duct inspection required prior to insulation installation: YES NO Progress Inspections Date Comments Final Inspection Date Comments Type License: By Master Title ❑ Master-Restricted City/Town ❑ Journeyperson Signature of Licensee Permit# ❑ Journeyperson-Restricted License Number: Fee$ ❑ Check at www.mass.gov/dpi I G/3i/)q In ector Signature of PernQpproval Project Summa Job: wri htsoft Date: Oct 22,2019 Entire House By: Rock Valley HVAC Inc. 296C Non otuck Street,Florence,Ma 01062 Phone:(413)535-7804 Email:rockvalleyhvac@yahoo.com Web:www.rockvalleyhvac.com License:SM2626 Project • • For: Kevin Perrier, Norwich Properties 257 Bridge Rd., Florence, Ma 01062 Phone: (413)246-9845 Provide and install Granby KLC-Et-088 high efficient oil fired furnace.Provide and install American Standard 410a cased coil and an American Notes: Standard 14 SEER AC unit. Desiqn Information Weather: Greenfield (Worcester Dd), MA, US Winter Design Conditions Summer Design Conditions Outside db -2 °F Outside db 85 °F Inside db 72 °F Inside db 68 °F Design TD 74 °F Design TD 17 °F Daily range M Relative humidity 50 % Moisture difference 42 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 45153 Btuh Structure 22637 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 45153 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 20373 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Tight) Structure 1344 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ftl 1200 1200 Equipment latent load 1344 Btuh Volume (ft3) 9600 9600 Air changes/hour 0.58 0.30 Equipment Total Load (Sen+Lat) 21717 Btuh Equiv.AVF (cfm) 93 48 Req. total capacity at 0.70 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80 AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 1597 cfm Actual air flow 1597 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.071 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.94 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. A- wrigt„tsoft 2019-Oct-2215:25:45 �� Right-Suite®Universal 2019 19.0.12 RSU24598 Page 1 sers\thero\Desktop\Heat Loads\257 Bridge Rd.rup Calc=MJ8 Front Door faces: N