17A-064 (4) 257 BRIDGE RD SM-2020-0015
COMMONWEALTH OF MASSACHUSETTS
CITY OF NORTHAMPTON
GIS#: 1374
Map: 17A !;
Block. 064
Lot: o01
SHEETMETAL PERMIT
�
Permit: SHEETMETAL
Category: renovation
Permit# SM-2020-0015 PERMISSION IS HEREBY GRANTED TO:
Project# JS-2020-000694
Est.Cost: $12,000.00 Contractor: License: Expires:
Fee Charged:$50.00 ROCK VALLEY HVAC Sheetmetal-2626 04/28/2020
Balance Due:$.00 Owner: NORWICH PROPERTIES LLC
#of Fixtures:' Applicant: ROCK VALLEY HVAC
DigSafe# AT: 257 BRIDGE RD
UseGroup I
ConstClass
ISSUED ON: 31-Oct-2019 AMENDED ON: EXPIRES ON:
TO PERFORM THE FOLLOWING WORK:
HVAC FOR 1 ST FLOOR
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Signature:
Fee Type: Receipt No: Date Paid: Check No: Amount:
Sheetmetal REC-2020-001487 30-Oct-19 1251 $50.00
212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:Ihasbrouck(&.northamptonma.gov
GeoTMS®2019 Des Lauriers Municipal Solutions,Inc.
File#SM-2020-0015
APPLICANT/CONTACT PERSON ROCK VALLEY HVAC
ADDRESS/PHONE box 1162 (413)535-7804
PROPERTY LOCATION 257 BRIDGE RD
MAP 17A PARCEL 064 001 ZONE URB(100)/
THIS SECTION FOR OFFICIAL USE ONLY:
PERMIT APPLICATION CHECKLIST
ENCLOSED REQUIRED DATE
ZONING FORM FILLED OUT
Fee Paid
Building Permit Filled out
Fee Paid
TypeofConstruction: HVAC FOR 1ST FLOOR
New Construction
Non Structural interior renovations
Addition to Existing
Accessory Structure
Building Plans Included:
Owner/Statement or License 2626
3 sets of Plans/Plot Plan
THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON
INFORMATION PRESENTED:
Approved Additional permits required(see below)
PLANNING BOARD PERMIT REQUIRED UNDER: §
Intermediate Project: Site Plan AND/OR Special Permit with Site Plan
Major Project: Site Plan AND/OR Special Permit with Site Plan
ZONING BOARD PERMIT REQUIRED UNDER: §
Finding Special Permit Variance*
Received&Recorded at Registry of Deeds Proof Enclosed
Other Permits Required:
Curb Cut from DPW Water Availability Sewer Availability
Septic Approval Board of Health Well Water Potability Board of Health
Permit from Conservation Commission Permit from CB Architecture Committee
Permit from Elm Street Commission Permit DPW Storm Water Management
" , � %�� — )a 3,
Sig ture of Building Official 10 Date
Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning
requirements and obtain all required permits from Board of Health,Conservation Commission,Department
of public works and other applicable permit granting authorities.
*Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact the Office of
Planning&Development for more information.
Commonwealth of Massachusetts R
Sheet Metal Permit
VFD
Date: 10/22/2019 Permit#,501"'10"/ OCT 3
c / 0 X41
Estimated Job Cost: $12,000 Permit Fee: $ J Q` 9
T�U !n!r!l!c
Plans Submitted: YES NO Plans Reviewed: YES NO °" ^41 o soo/Vs
Business License #824 Applicant License # SM2626 L5/
Business Information: Property Owner/Job Location Information:
Name: Jesse Fortier (Rock Valley HVAC) Name: Kevin Perrier(Norwich Properies)
Street: 296C Nonotuck Street Street: 257 Bridge Rd.
City/Town: Florence City/'Town: Florence
Telephone: (413) 535-7804 Telephone: (413) 246-9845
Photo I.D. required/Copy of Photo I.D. attached: YES NO
Staff Initial
J-1 /M-1-unrestricted license
J-2/M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less
Residential: 1-2 family ✓ Multi-family Condo /Townhouses Other
Commercial: Office Retail Industrial Educational
Institutional Other
Square Footage: under 10,000 sq. ft. ✓ over 10,000 sq. ft. Number of Stori s:2
Sheet metal work to be completed: New Work: Renovation:
HVAC ✓ Metal Watershed Roofing Kitchen Exhaust System _
Metal Chimney/Vents Air Balancing
Provide detailed description of work to be done:
Provide and install complete HVAC system, fabricate and install custom fabricated sheet metal duct
system for first floor. All ductwork to be sealed and insulated to energy star standards and installed in
conditioned space. All equipment and ductwork sized according to Manual J 8th edition heat load
calculation.
INSURANCE COVERAGE:
I have a current liabili insurance policy or its equivalent which meets the requirements of M.G.L. Ch. 112 Yes XNo ❑
If you have checked Yes, indicate the type of coverage by checking the appropriate box below:
A liability insurance policy 0 Other type of indemnity ❑ Bond ❑
OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the
Massachusetts General Laws,and that my signature on this permit application waives this requirement.
_ Check One Only
`—_ Owner Agent ❑
Signature of Owner or Owner's Agent
By checking this box•,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and
accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will
be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of theGener Laws.
Duct inspection required prior to insulation installation: YES NO
Progress Inspections
Date Comments
Final Inspection
Date Comments
Type License:
By Master
Title ❑ Master-Restricted
City/Town ❑ Journeyperson
Signature of Licensee
Permit# ❑ Journeyperson-Restricted
License Number:
Fee$ ❑
Check at www.mass.gov/dpi
I G/3i/)q
In ector Signature of PernQpproval
Project Summa Job:
wri htsoft Date: Oct 22,2019
Entire House By:
Rock Valley HVAC Inc.
296C Non otuck Street,Florence,Ma 01062 Phone:(413)535-7804 Email:rockvalleyhvac@yahoo.com Web:www.rockvalleyhvac.com License:SM2626
Project • •
For: Kevin Perrier, Norwich Properties
257 Bridge Rd., Florence, Ma 01062
Phone: (413)246-9845
Provide and install Granby KLC-Et-088 high efficient oil fired furnace.Provide and install American Standard 410a cased coil and an American
Notes: Standard 14 SEER AC unit.
Desiqn Information
Weather: Greenfield (Worcester Dd), MA, US
Winter Design Conditions Summer Design Conditions
Outside db -2 °F Outside db 85 °F
Inside db 72 °F Inside db 68 °F
Design TD 74 °F Design TD 17 °F
Daily range M
Relative humidity 50 %
Moisture difference 42 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 45153 Btuh Structure 22637 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 45153 Btuh Use manufacturer's data n
Rate/swing multiplier 0.90
Infiltration Equipment sensible load 20373 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 1 (Tight) Structure 1344 Btuh
Ducts 0 Btuh
Central vent(0 cfm) 0 Btuh
Heating Cooling (none)
Area(ftl 1200 1200 Equipment latent load 1344 Btuh
Volume (ft3) 9600 9600
Air changes/hour 0.58 0.30 Equipment Total Load (Sen+Lat) 21717 Btuh
Equiv.AVF (cfm) 93 48 Req. total capacity at 0.70 SHR 2.4 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make
Trade Trade
Model Cond
AHRI ref Coil
AHRI ref
Efficiency 80 AFUE Efficiency 0 SEER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 °F Total cooling 0 Btuh
Actual air flow 1597 cfm Actual air flow 1597 cfm
Air flow factor 0.035 cfm/Btuh Air flow factor 0.071 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.94
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
A- wrigt„tsoft 2019-Oct-2215:25:45
��
Right-Suite®Universal 2019 19.0.12 RSU24598 Page 1
sers\thero\Desktop\Heat Loads\257 Bridge Rd.rup Calc=MJ8 Front Door faces: N