994 Mass DEP Water Report 2015 I
I
Commonwealth of Massachusetts
Executive Office of Energy &Environmental Affairs
Department of Environmental Protection
One Winter Street Boston, MA 02108.617-292-5500
Charles D.Baker Matthew A.Beaton
Governor Secretary
i
Karyn E.Polito Martin Suuberg
Lieutenant Governor Commissioner
I
APPROVAL FOR GENERAL USE
Pursuant to Title 5,310 CMR 15.000
Name and Address of Applicant:
Infiltrator Water Technologies,LLC.
P.O.Box 768
6 Business Park Road
Old Saybrook,CT 06475
Trade name of technology and model: High Capacity chamber, High Capacity H-20 chamber', Quick4
High Capacity chamber, Quick4 High CapacityHD chamber, Quick4 Plus High Capacity chamber (8-
inch invert), Quick4 PlusHigh Capacity chamber (13-inch invert), Standard. chamber, Quick4 Standard
chamber, Quick4 Standard HD chamber, Quick4 Plus Standard chamber (5.3-inch invert), Quick4 Plus
Standard chamber (8.0-inch invert), Quick4 Plus Standard LP (Low Profile) chamber (3.3-inch invert),
Quick4 Plus Standard LP (Low Profile) chamber (8-inch invert), Infiltrator 3050 (Storm Tech SC-740)
chamber,Equalizer 24 chamber, Quick4 Equalizer 24 chamber,Equalizer 36 chamber, Quick4 Equalizer
36 chamber,Quick4 Equalizer 24 LP(Low Profile)chamber(6,inch invert),and Quick4 Equalizer 24 LP
(Low Profile) chamber(21 inch invert) (hereinafter the"System"). Schematic drawings of the System and
a design and installation manual are a part of this Certification. This approval allows the installation of
the above identified chambers without aggregate.
i
Transmittal Number: X259183
Date of Revision: February 19,2015,modified June 12,2015
Authority for Issuance
Pursuant to Title 5 of the State Environmental Code, 310 CMR 15.000,the Department of Environmental
Protection hereby issues Ithis Certification to: Infiltrator Water Technologies, LLC., P.O. Box 768, 6
Business Park Road, Old Saybrook, CT 06475 (hereinafter "the Company"), for General Use of the
System described herein.!The sale, design, installation, and use of the System are conditioned on
compliance ,by the Company, the Designer, the Installer and the System Owner with the terms
and conditions set forth below. Any noncompliance with the terms or conditions of this
Approval constitutes a violation of 310 CMR 15.000.
June 12,2015
David Ferris,Director Date
Wastewater Management Program
Bureau of Water Resources
I
I
This information is available in alternate format.Call Michelle Waters-Ekanem,Diversity Director,at 617-292-5751.TTY#MassRelay Service 1-800-439-2370
MassDEP Website:www.mass.gov/dep
i
Printed on Recycled Paper
I
Infiltrator Chamber,Infiltrator Water Technologies. Page 2 of 6
Approval for General Use—June 12,2015
I
I. Design Standards
1. The models listed in Table 1 are covered under this Certification.
i
Table 1: Chamber Dimensions
Dimensions Invert
Model W x L x H Height
Inches Inches
E ualizer J24 15 x 100 x 11 6
Quick4 E�ualizer 24 16 x 48 x 11 6
Quick4 Equalizer 24 LP (6-inch invert) 16 x 48 x 8 6Z
Quick4 Equalizer 24 LP(2-inch invert) 16 x 48 x 8 2
E ualizerl36 22 x 100 x 13.5 6
Quick4 E' ualizer 36 22 x 48 x 12 6
Standard Chamber 34 x 75 x 12
,Quick4 S 348 x 12 8
Quick4 Standard HD 34 x 48 x 12 8
Quick4 Plus Standard 5.3-inch invert) 34 x 48 x 12 5.3
Quick4 Plus Standard(8-inch invert) 34 x 48 x 12 8
Quick4 Plus Standard LP(3.3-inch invert) 34 x 48 x 8 3.3
Quick4 Plus Standard LP (8-inch invert) 34 x 48 x 8 83
Infiltrator 3050 or StormTech SC-740 51 x 85.4 x 30 22.254
High Capacity Chamber 34 x 75 x 16 11
High Capacity H-201 Chamber 34 x 75 x 16 11
Quick4 High Capacity 34 x 48 x 16 11.5
Quick4 High Capacity HD 34 x 48 x 16 11.5
Quick4 Plus High Capacity 8-inch invert) 34 x 48 x 14 8
Quick4 Plus High Capacity(13-inch invert) 34 x 48 x 14 135
1 This approval allows the use of the high capacity H-20 chambers but makes no determination
as to the�chambers meeting the H-20 loading requirements.
2 Includes Infiltrator MultiporfM invert adapter attached to the side of the end cap.
3 Includes Quick4 Plus Periscope adapter attached to the top of the Quick4 Plus All-in-One 8
Endcap.
4 Only systems installed with this invert height shall be allowed to use the effective leaching
area associated with this model in Table 2.
5 Includes tQuick4,P1us Periscope adapter attached:to the top of the Quick4 Plus All-in-One 12
Endcip.
2. The System is an open-bottom leaching unit molded from polyolefin resin. It can
be installed without aggregate or distribution pipe as an absorption trench or as a
bed or field. If the System is installed with stone aggregate then the "Effective
Leaching Area' in Tables 2 -and 3 is not applicable, and must be designed in
accordance with the provisions of 310 CMR 15.000.
I
Infiltrator Chamber,Infiltrator Water Technologies. Page 3 of 6
Approval for General Use-June 12,2015
3. The total effective leaching area for any Chamber Model shall be calculated by
multiplying the Effective Leaching Area per square foot of chamber times the
total lengi h of chamber from end cap to end cap including end caps.
4. For new construction or upgrades,the applicant can size-the System in a trench
configuration,using the effective leaching areas presented in Table 2.
Table 2: Effective Leaching Area in Trench Configuration for New
Construction and Remedial Sites6
i
Effective Effective
Model Leaching Leaching
Area Area
SF/LF SF/LF
Equalizer 24 3:76 N/A
Yt� Quick4 Equalizer 24 3.90 N/A
I C�1 i 11 Ok_ 1 Quick4 Equalizer 24 LP (6-inch invert) 3.90 N/A
Quick4 E ualizer 24 LP (2-inch invert) 2.78 N/A
Equalizer 36 4.73 N/A
(f Quick4 Equalizer 36 4.73 N/A
S -61L- N/A
Quick4 Standard 6.96 N/A
Cp. d\ QUIZO Standard HD N/A
cc�� Quick4 Plus Standard 5.3-inch invert6.20 N/A
0��'2.1'c Quick4 Plus Standard 8-inch invert6.96 N/A
e�jQuick4 Plus Standard LP (3.3-inch invert) 5.65 N/A
7. Quick4 Plus Standard LP (8-inch invert) 6.96 N/A
�� Infiltrator 3050 or StormTech SC-740 N/A 6.71
1 Hight Capacity Chamber 7.79 N/A
V Hight Capacity H-201 Chamber' 7.79 N/A
�%i Quick4 High Capacity 7.93 N/A
Quick4 High Capacity HD 7.93 N/A
Quick4 Plus Iligh Capacity 8-inch invert) 6.96 N/A
Quick4 Plus High Capacity(13-inch invert) 7.93 N/A
6. Effective April 21,2006,310 CMR 15.251(1)(b)maximum trench width is 3 feet.
'.Effective leaching area is equal to 1.67(bottom width+(2x invert height))for Systems
3 feet of less in width.
8.Effective leaching.area is equal to 1.0(3 +(2x invert Height))for Systems with a width
greater than 3 feet.
9.The maximum trench width allowed to calculate effective leaching area is 3 feet.
5. Systems installed on remedial sites shall be allowed to utilize the effective
leaching areas presented in Tables 2 or 3,or additional reductions in soil
,absorption system may be allowed. In no instance shall)the reduction in the soil
absorption system required in 310 CMR 15.242 exceed.the maximum reduction
allowed for alternative systems approved in accordance with 310 CMR 15.284.
IV%
. I
Infiltrator Chamber,Infiltrator water Technologies. Page 4 of 6
Approval for General Use—Juni 12,2015
6. For new construction or an-upgrade,the applicant can size the System in bed or
field configuration,using the effective leaching areas presented in Table 3.
Table 3: Effective Leaching Area for Bed or Field Configuration New
Construction and Remedial Sites
Effective
Leaching10
Model Area
SF/LF
Equalizer 24 2.09
Quick4 Equalizer 24 2.23
Quick4 Equalizer 24 LP (6-inch invert) 2.23
Quick4 E ualizer 24 LP (2-inch invert) 2.23
Equal izer 36 3.06
Quick4 Equalizer 36 3.06
Standard Chamber 4.73
Quick4 Standard 4.73
Quick4 Standard HD 4.73
Quick4 Plus Standard(5.3-inch invert) 4.73
Quick4 Plus Standard 8-inch invert4.73
Quick4 Plus Standard LP (3.3-inch invert) 4.73
Quick4 Plus Standard LP (8-inch invert) 4.73
Infiltrator 3050 or StormTech SC-740 7.10
High Ca acity Chamber 4.73
High Capacity H-20' Chamber 4.73
Quick4 High Capacity 4.73
Quick4 High Capacity HD 4.73
Quick4 Plus High Capacity(8-inch invert) 4.73
Quick4 Plus High Capacity(13-inch invert) 4.73
'° Effecti I ve Leaching area is equal to 1.67 times bottom width only.
7. When the System is used with a secondary treatment unit approved in accordance
with 310 CMR 15.284 or 15.288, additional reductions in soil absorption system
may be allowed. In these situations the reduction in the,SAS cannot exceed the
maximum allowed under the secondary treatment units approval. In no.instance
shall the reduction in the soil absorption system area required in 310 CMR 15.242
exceed the maximum reduction allowed for alternative systems approved in
accordance with 310 CMR 15.284.
H. Special Conditions
I
1. The System is an approved Alternative Chamber for use as an Alternative Soil
Absorption System. In addition to the Special Conditions contained in this
Approval,the System shall comply with the"Standard Conditions for Alternative
SAS with General Use Certification and/or Approved for Remedial Use"(the
I
I
Infiltrator Chamber,Infiltrator Water Technologies. Page 5 of 6
Approval for General Use—June 12,2015
1
'Standard Conditions'),except where stated otherwise in these Special
Conditions.
2. New Construction This Certification is for the installation of a System to serve
new construction or an existing facility with a proposed increase in flow,for
which a site evaluation in compliance with 310 CMR 15:000 has been approved
by the Approving Authority and the site meets the siting requirements for new
.construction,as provided in ParaUMh 6 in section II Design and Installation
Requirements of the Standard Conditions.
3. Remedial Site This General Use Certification also applies to the installation of a
System for the upgrade or replacement of an existing failed or nonconforming
system,provided that the facility meets the siting requirements for upgrades, as
provided in ParagMh 7 in section II Design and Installation Requirements of the
Standard Conditions
4. The System shall be exempt from the minimum inlet spacing requirements of 310
CMR15.1253.
5. a System shall have a minimum of one inspection port through the top of one
of;the chambers. The inspection port shall be napped with a screw type cap and
accessible' to within three inches of finish grade.
6. When the System is installed in trench configuration,then the system shall
comply with these requirements:
,dfLengih(each trench) 100 feet maximum(310 CMR 15.251(1)(a)); 33 '
b Width(each trench)2 feet minimum to 3 feet maximum(310 CMR 3-Lit,
15.251(1)(b)). - Chambers greater than 3 feet wide,when specifically
approved,are subject to other Special Conditions and limitations;
c) The minimum separation distance between any two trenches shall be two
t
esthe.effective width or depth of each trer}ch, whichever is greater, or V�
ere the area between trenches is designated as reserve area,three times the
effective width or depth of each trench,whichever is greater(3 10 CMR
15.2 1(1)(d));
d) The effective leaching area shall be calculated using!the bottom area and a
maximum of two feet(per side) of side wall area for each trench(3 10 CMR
15.2 1(1)(e));
e) Trenches shall be situated,where possible,with their long dimension
perpendicular to the slope of the natural soil. Where,possible they shall follow
the contour lines(3 10 CMR 15.251(2));
f) Trenches constructed at different elevations shall be designed to prevent
effluent from the higher trench(es)flowing into the lower trench(es) (3 10
CMR 15.251(3));
g) The�rea between trenches may be designated as system reserve area only
where the separation distance between the excavation sidewalls of the primary
trenches is at least three times the effective width or,depth of each trench,
whichever is greater(3 10 CMR 15.251(4))-Chambers greater than 3 feet
I
I
i
Infiltrator Chamber,Infiltrator Water Technologies. Page 6 of 6
Approval for General Use—June 12,2015
I
wide,I when specifically approved, shall be separated by three times the actual
width and are subject to other Special Conditions and limitations; and
h) Effluent distribution lines exceeding 50 feet in length shall be connected and
venting provided in accordance with 310 CMR 15.241 (310 CMR
�\(�
15.2511(11)).
7. When installed in trench configuration,approved Alternative Chambers greater
than 3 feet wide:
a) shall be installed with a minimum separation distance between any two
trenches of two times the actual width of the chamber,or where the area
between trenches is designated as reserve area,three times the actual width of
the chamber; and
b) shall only be entitled to a maximum effective width of 3 feet for the purposes
of calculating total effective leaching area.
8. When installed in a bed or field configuration,the System may be installed
without distribution piping,but must comply with the following requirements in
R
310 CM15.252:
a) the use of leaching beds or fields is restricted to systems with a calculated
design flow of less than 5,000 gpd per leaching bed or field(310 CMR
15.252(1));
b) the maximum.length of chambers in series shall be 100 feet(310 CMR
15.252(2)
C) separation distance between adjacent beds/fields shall be ten feet(3 10 CMR
15.252(2)(f)); and
d) the,effective leaching area shall include only the bottom area,not the
sidewalls(3 10 CMR 15.252(2)(1)).
9. For Systems constructed in fill and installed,the System;shall be installed as
specified in 310 CMR 15.255 Construction in Fill,except the minimum 15 foot
horizontal separation distance to be provided between the soil absorption area and
the adjacent side slope shall be measured.horizontally from the top of the
chamber.
10. The System is exempt from 310 CMR 15.287, specifically items: (5)requiring
written notification of alternative system prior to property transfer, (6)need for a
certified operator,(9)need for an operation and maintenance contract with an
operator and(10)deed notice requirement.