Loading...
03-028 (11) 599 COLES MEADOW RD BP-2020-0219 GIS#: COMMONWEALTH OF MASSACHUSETTS Man:Block:03-028 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2020-0219 Proiect# JS-2020-000361 Est.Cost: $16777.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: PIONEER VALLEY PHOTOVOLTAICS 111266 Lot Size(sq.ft.): 104936.04 Owner: ROBINSON STEPHEN C&HEIDI C/O LISA LYNNE COLE Zoning: RR(100)/WSP(100)/ Applicant: PIONEER VALLEY PHOTOVOLTAICS AT. 599 COLES MEADOW RD Applicant Address: Phone: Insurance: 311 WELLS ST- SUITE B (413) 772-8788 Workers Compensation GREEN FIELDMA01301 ISSUED ON.812112019 0.00.00 TO PERFORM THE FOLLOWING WORK:10 PANEL SOLAR ARRAY ON ROOF - 3.6KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Sid!nature: FeeType: Date Paid: Amount: Building 8/21/2019 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner f Department use only City of Northam ton r t , of Permit: y � r Building Depart ent Curb Cu Drive'4vay Permit L 212 Main Str et AUG 2 0 2Ze'r/Zptic vailabilitRoom 10 e/ ell A ailability Northampton, M 010 F Two S is of tructural Plans phone 413-587-1240 F -58rN'c Pla s ON, A ltibr Speci y APPLICATION TO CONSTRUCT,ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION � /- J D -'-� l 1.1 Property Address: This section to be completed by office Map Lot _Unit 599 COLES MEADOW RD NORTHAMPTON, MA 01060 Zone Overlay District Elm St.District CB District SECTION 2 -PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: SCOTT COLE & LISA COLE 599 COLES MEADOW RD NORTHAMPTON, MA 01060 Name(Print) Current Mailing Address: 508-965-6663 See Attachment A Telephone Signature 2.2 Authorized Agent: Pioneer Valley Photovoltaics 311 Wells St. Greenfield, MA 01301 Name(Print) Current Mailing Address: C 413-772-8788 Signature Telephone SECTION 3 -ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building 6711 (a)Building Permit Fee 2. Electrical 10066 (b) Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 6. Total = (1 +2+ 3+4+ 5) 16777 1 Check Number This Section For Official Use Only Building Permit Number: Date Issued: Signature: 2 �� Building Commissioner/Inspector of Buildings Date buildingpermits @ pvsquared.coop EMAIL ADDRESS (REQUIRED; EITHER HOMEOWNER OR CONTRACTOR) Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage Open Space Footage 0r0 (Lot area minus bldg&paved parking) #of Parking Spaces Fill: (volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO O DON'T KNOW O YES O IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO O DON'T KNOW O YES O IF YES: enter Book Page and/or Document # B. Does the site contain a brook, body of water or wetlands? NO O DON'T KNOW O YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained O Obtained O Date Issued: C. Do any signs exist on the property? YES O NO O IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES O NO O IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO O IF YES,then a Northampton Storm Water Management Permit from the DPW is required. 1 SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alterations) ❑ Roofing ❑ Or Doors E3 Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [[] Siding [ED] Other[M Brief Description of Proposed Installation of racking system for solar PV Work: Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet sa. If New house and or addition to existing housing, complete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No . I. Septic Tank City Sewer Private well City water Supply SECTION 7a -OWNER AUTHORIZATION -TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Scott Cole I, , as Owner of the subject property PV Squared (Pioneer Valley Photovoltaics) hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. See Attachment A See Attachment A Signature of Owner Date PV Squared as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Chris Krezmien Print Name C T/{'� 8/19/19 Signature of Owner/Agent Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: Daniel Gomez Gonzalez License Number CS-111266 Address Expiration Date 03/14/2021 Signature / Telephone 413-772-8788 9. Registered Home Improvement Contractor: Not Applicable ❑ Pioneer Valley Photovoltaics Cooperative Company Name Registration Number 311 Wells Street, Suite B, Greenfield, MA, 01301 140077 Address Expiration Date 413-772-8788 Telephone 09/15/2019 SECTION 10-WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes.......Fy7 No...... ❑ �DocuSign Envelope ID:F7B2C191-DOCB-41F3-A6B6-A44C204FO96B ATTACHMENT A AUTHORIZATION TO PROCEED AND SERVE AS AUTHORIZED AGENT I hereby agree to the Project as set out above,and I agree to pay the contract price according to the Terms of Payment. I further agree to the Terms and Conditions attached hereto as a part of this Proposal and Agreement.I hereby authorize Pioneer Valley Photovoltaics Cooperative to proceed with the above-referenced Project in accordance with this Agreement. I further authorize Pioneer Valley Photovoltaics Cooperative, or its designated representative, to obtain required permits for this project on behalf of the Owner. I will allow any photographs or videos of this project to be used by Pioneer Valley Photovoltaics Cooperative for marketing purposes.A check for the First Payment is enclosed and I am returning this Agreement within 21 days of the Proposal date. Scott Cole 5/9/2019 1 7:20 AM EDT Printed Name Date CDotu Signed by. s.Gq Otic owner 6DL9E38BC1)l04SL Signature Title Make a Payment Online Proposal and Agreement g 00014767 Page 7 of 13 Scott Cole-May 7,2019 Commonwealth cif MassachuAbet Is Division of Professional Licensure Board of Building Regulations and Standards Construction Supervisor CS-1112+66 Expires 011412021 DANIEL GOMEZ-GONZALEZ 43 HATFIELD STREET NORTHAMPTON MA 01060 Office of Consumer Affairs and Business Regulation. One Ashburton Place - Suite 1301 Boston, Massachusetts 02108 Home Improvement Contractor Registration Type: Supplement Card 40077 PIONEER VALLEY PHOTOVOLTAICS COOP Re xpiration: 9/15/2 311 WELLS ST SUITE ti Expiration: 09/15/2019 GREENFIELD,MA 01301 Update Address and Return Card.. .. .sGA'.0 20M.A:vo - 'QM"of Consumer Affairs E Business Regulation NOME IMPROVEMENT CONTRACTOR Registration valid for individual use only TYPE:Sunolement Card before the expiration date. R found return to. Rgoistration Exfiration Office of Consumer Affairs and Business Regulation _ 1400TT 09/15/2019 10 Park Plaza�Suite 5170 . PIONEER VALLEY PHOTOVOLTAICS COOP Boston.MN 0 116 i CHRISTOPHER KREZMIEN A �( .311 WELLS ST SUITE B GREENFIELD:MA 01301 N t valid WitilO t 'gnature Undersecretary DATE(MM/DD/YYYY) AC"R" CERTIFICATE OF LIABILITY INSURANCE o,/oa/2o,s � THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Linda Powers,CRIS NAME: Webber&Grinnell PHONE (413)586-0111 FAX (413)586-6481 .'C, IC No Ext: A/C,No): 8 North King Street E-MAIL (powers@webberandgrinnell.com ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC# Northampton MA 01060 INSURER A: Ohio Casualty/Liberty 24074 INSURED INSURER B: Ohio Security/Liberty 24082 Pioneer Valley PhotoVoltalcs Cooperative,Inc. INSURER C: Continental Indemnity/AUW Attn:Kim Pinkham INSURER D: 311 Wells Street,Suite B INSURER E: Greenfield MA 01301 INSURER F COVERAGES CERTIFICATE NUMBER: Master Exp 1-2020 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADUL 5UbK POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER MM/DD/YYYY MM/DD/YYYY LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE �OCCUR PREMISES Ea occurrence $ 300,000 MED EXP(Any one person) $ 5,000 A BKS57072282 01/01/2019 01/01/2020 PERSONAL&ADV INJURY $ 1'000'000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 X POLICY ❑ PRO ❑ 2,000,000 JECT LOC PRODUCTS- $ OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000,000 Ea accident X ANY AUTO BODILY INJURY(Per person) $ B OWNEDOS SCHEDULED BAS57072282 01/01/2019 01/01/2020 BODILY INJURY(Per accident) $ AUTONLY AUTOS X HIRED �/ NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident X $1 K toll X $1 K comp Underinsured motorist BI $ 300,000 X UMBRELLA LAB OCCUR EACH OCCURRENCE $ 3,000,000 AEXCESS LIAB HCLAIMS-MADE US057072282 01/01/2019 01/01/2020 AGGREGATE $ 3'000'000 DED I I RETENTION$ $ WORKERS COMPENSATION X1 SPER TATUTE EORH AND EMPLOYERS'LIABILITY y/N ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ 1'000'000 C OFFICER/MEMBER EXCLUDED? F N/A 37-592871-01-01(Ma,Ct,&NY) 01/01/2019 01/01/2020 (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ Business Pers Property $1,750,000 A Commercial Property BKS57072282/NYR 01/01/2019 01/01/2020 Installation $50,000 Transportation $75,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Worker's compensation ncludes Ma,CT,and NY CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Evidence of Insurance ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts Department of Industrial Accidents 1 Congress Street,Suite 100 Boston,MA 02114-2017 '< www mass.gov/dia «'orkers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers- TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name (Business/Organization/Individual):Pioneer Valley Photovoltaics Cooperative Inc. DBA PV Squared Solar Address:311 Wells Street, SuiteB City/State/Zip: Greenfield MA 01301 Phone#:413-772-8788 Are you an employer?Check the appropriate box: Type of project(required): l.❑✓ I am a employer with 48 employees(full and/or part-time).* 7. ❑New construction 2.❑I am a sole proprietor or partnership and have no employees working for me in 8. ❑Remodeling any capacity.[No workers'comp.insurance required.] 9. El Demolition 3.M I am a homeowner doing all work myself.[No workers'comp.insurance required.]t 10❑Building addition 4.❑I am a homeowner and will be hiring contractors to conduct all work on my property. I will ensure that all contractors either have workers'compensation insurance or are sole 11.❑Electrical repairs or additions proprietors with no employees. 12.❑Plumbing repairs or additions 5.❑I am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13.❑Roof repairs These sub-contractors have employees and have workers'comp.insurance.t 14.❑✓ Other Solar PV 6.F1We are a corporation and its officers have exercised their right of exemption per MGL c. 152,§1(4),and we have no employees.[No workers'comp.insurance required.] 'Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. $Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:Ohio Casualty/Liberty Policy#or Self-ins.Lic.#:BKS57072282 Expiration Date:01/01/2020 Job Site Address:599 COLES MEADOW RD City/State/Zip:NORTHAMPTON,MA 01060 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. Ido hereby cerci under epains andpenalties ofperjury that the information provided above is true and correct. Si nature: �j — Date: 8/19/19 Phone#:413-7 2- 788 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: COLE#2, 599 COLES MEADOW RD, NORTHAMPTON, MA 01060 LOWER SOUTH ROOF r4j^ ARRAY ON LOWER tit SOUTH ROOF M ARRAY LAYOUT LOCUS MAP Owner: SCOTT COLE Address: 599 COLES MEADOW RD, NORTHAMPTON, MA 01060 Phone: 508-965-6663 e-mail: vermontahs@hotmail.com System Size: 3.6 kW DC PV Array: • LOWER SOUTH ROOF: 10 modules (SPR-X22-360), in portrait • 4 rows of 4, 3, 2, & 1 modules each, in landscape • See sketch above. Mounting: IronRidge rails on L-feet on Ecofasten Quickfoot bases Roof Structure: 2x 10 nom rafters @16"oc;See PE letter. Roofing Material: asphalt shingles over strand board sheathing PROJECT INFORMATION: N SQUq • Owner: Scott Cole Q RSO Lisa Cole • Address: 299 Coles Meadow Road // �f Northampton, MA 01060 R'Rr . so` PV Squared Solar • Phone: 508-965-6663 311 Wells Street,Suite B Greenfield,MA 01301 • Email: vermontahs@hotmail.com design@pvsquared.coop 413-772-8788 • System Size: 3.6 kW DC-STC Joe: Cole#2 • Modules: SunPower SPR-X22-360 ---- • Rail: Ironridge XR1 00 SITE: 299 Coles Meadow Road • Bases: Ecofasten Quikfoot Northampton,MA 01060 • Snow Load: 40 lbs REVISIONS: • Wind Speed: 117 mph ROOF STRUCTURE: EXISTING ARRAY • 40° 2x10 rafters @ 16"O.C. ROOF MATERIAL: Site Plan A No scale NEW ARRAY • Asphalt shingles PROJECT NOTES: Description Item Qty- 1. ty•1. Framing location to be verified on site. QuikFoot AL Base Plate QF-AL-M 36 2. Slide rail assembly as needed to avoid Flashing, QuickFoor Black QFL-BLK-812 36 interfering with splices or bases. 3. Unless otherwise noted bases are staggered Slotted L Foot Sin Black SCL-101 3 ANODZD 36 and spaced not more than 48" O.C. Fastener 5/16x3-1/8in GRKRSS2 72 4. Additional or alternative bases may be used GEO-CEL clear PROFLEX26100 2 TITLE: Site Plan to meet actual roof conditions. Ironridge XR100 11' Black XRL1 00-1 32BLK 7 Ironridge XR100 17' Black XRL100-204BLK 2 Ironridge XR100 Splice SPLIC2 2 BY* 12285 BY: JG Ironridge Low Profile Grounding Lug IRN GD-LUG-003 4 DATE: 8/15/2019 Ironridge Rail Clamp, Black UFO-CL001-B 30 Ironridge Rail Stopper, Black,XXmm UFO-STP-xxMM-BLK 16 SCALE No Scale Ironridge XR100 End Cap(1 Pair VR) XR100ENDCAP 8 SIZE: 8-1/2•X11° Ironridge Plastic Clip TW029-4000-077 20 Wire Management Clip DCS-1307 40 PV-01 B Mechanical Balance of System(MBOS) (Sheet 1 of 2) " 4GV4 a,Rr .` so,♦ PV Squared Solar 311 Wells Street,Suite B Greenfield,MA 01301 design@pvsquared.coop 413-772-8788 (1 2 1 ') 3s� „ JOB: Cole#2 SITE: 299 Coles Meadow Road (11 ) 125" Lr) Northampton,MA 01060 N REVISIONS: Ln � w O Q 40° 2x10 rafters @ 16" O.C. (11' 132' 11 -116Y " Array 24636" Roof-336" Array Layout A 3/16"=1'0" TITLE: Array Layout 2" RAIL SPECIFICATIONS 16" 1136"(46mm) IDN#: 12285 Make&Model: Ironridge XR100 — BY: JG Clamp Torque: 80 in-lbs L-Foot Torque: 250 in-lbs - - - -- DATE: 8/15/2019 Max Span: 75" - SCALE: As Shown Max Cantilever: 25" I SIZE 8.1/2"x11" MODULE SPECIFICATIONS: 6136 D02 Make& Model: SunPower SPR-X22-360 I V Clamp Range: 2"to 16"on all sides SPR-X22-360 Dimensions Module Size: 61-5/16"x 41-3/16"x 1-13/16"(46mm) B 1/4"=1'-0" (Sheet 2of2) X SUNPOWER® SunPower X-Series: X22-360 SunPowerO Residential DC Panel SunPower X-Series panels combine the top efficiency,durability and warranty available in the market today,resulting in more long-term energy and savings.1,2 Maximum Power. Minimalist Design. iii' Industry-leading efficiency means more power and savings per available iii space.With fewer panels required,less is truly more. Highest Lifetime Energy and Savings Designed to deliver 60%more energy in the same space over 25 years in real-world conditions like partial shade and high temperatures.2 V 15096 -- - - -- - 3 140% ------ ------ Fundamentally Different. Q ,311% And Better. 20% SunPower Up to 110% 60% � 100% More Lifetime W 90% Energy 80% A Conventional Panel j 70% N 60% _ 0 5 10 15 20 25 The SunPower Maxeon®Solar Cell Years of Operation • Enables highest efficiency panels available Z © Best Reliability, Best Warranty • Unmatched reliability • Patented solid metal foundation With more than 25 million panels deployed around the prevents breakage and corrosion.. world,SunPower technology is proven to last.That's why we stand behind our panel with the industry's best 25-year Combined Power and Product Warranty, AML CA-13. including the highest Power Warranty in solar. craaemaaae qw. � 100% ., 3 98% As Sustainable As Its Energy949%6 a • Ranked#1 in Silicon valley Toxics 92% SunPower, 1200 Coalition 2015 Solar Scorecard° a 90% 1-Series and X-Series v se% More • First solar panels to achieve Cradle to 86% conventional Panel Power 84% in Year Cradle CertifiedTm Silver recognition 5 82% 25 • Contributes to more LEED categories 3 80% than conventional panels 6. o Years of Operation X-Series:X22-360 SunPower®Residential DC Panel SPR-X22-360 SPR-X21-345 Temperature —40°F to+185°F(-40°C to+85°Q Nominal Power(Pnom)7 360 W 345 W Impact Resistance 1 inch(25 mm)diameter hail at 52 mph(23 m/s) Power Tolerance +5/045 +5/096 Appearance Class A+ Panel Efficiency 22.11% 21.2% Solar Cells 96 Monocrystalline Maxeon Gen III Rated Voltage(Vmpp) 59.1 V 57.3 V Tempered Glass High-transmission tempered anti-reflective Rated Current(Impp) 6.09 A 6.02 A Junction Box IP-65,MC4 compatible Open-Circuit Voltage(Voc) 69.5 V 68.2 V Weight 41 lbs(18.6 kg) Short-Circuit Current(Isc) 6.48 A 6.39 A G5 frame: Wind:62 psf,3000 Pa front&back Max.System Voltage 600 V UL&1000 V IEC Max.Load Snow:125 psf,6000 Pa front Maximum Series Fuse 15A G3 Frame: Wind:50 psf,2400 Pa front&back Power Temp Coef. —0.29%/°C Snow:112 psf,5400 Pa front Voltage Temp Coef. —167.4 mV/°C Frame Class 1 black anodized(highest AAMA rating) Current Temp Coef: 2.9 mA/°C 46 mm 1558 mm [1.8 in] Standard Tests 8 UL1703(Type 2 Fire Rating),IEC 61215, [61.3 in] �I IEC 61730 Quality Management Certs ISO 9001:2015,ISO 14001:2015 EHS Compliance RoHS,OHSAS 18001:2007,lead free, Recycle Scheme,REACH SVHC-163 1046 mm Sustainability Cradle to Cradle Certified""^Silver. [41.2 in] "Declare."listed. Ammonia Test IEC 6271.6 Desert Test 10.1109/PVSC.2013.6744437 Salt Spray Test IEC 61701 (maximum severity) PID Test 1000V:IEC 62804,PVEL 600 hr duration Available Listings UL,TUV,MCS,FSEC,CEC G5 FRAME PROFILE G3 FRAME PROFILE InvisiMountm Compatible Not InvisiMount Compatible 1 Ec E� Eco Em 1 SunPower 360 W compared to a Conventional Panel on same-sized arrays(260 W,16% c v efficient,approx.1.6 ml),4%more energy per watt(based on PVSyst pan files),0.75%/yr slower degradation(Campeau,Z.et al."SunPower Module Degradation Rate,"SunPower 30 mm white paper, 2013). [1 2 in] 32 mm[1.3 in]LONG SIDE 2 Based on search of datasheet values from websites of top 10 manufacturers per IHS,as of 22 mm[0.9 in]SHORT SIDE January 2017. 3#1 rank in"Frapahofer PV Durability Initiative for Solar Modules:Part 3".PVrech.Power Magazine,2015.Campeau,Z.et al.'SunPower Module Degradation Rate,'SunPower white G5 frames have no mounting holes.Please read the safety and paper,2013. installation guide. 4 SunPower is rated#1 on Silicon Valley Toxics Coalition's Solar Scorecard. 5 Cradle to Cradle Certified is a multi-attribute certification program that assesses products and materials for safety to human and environmental health,design for future use cycles, and sustainable manufacturing. 6 X-Series and E-Series panels additionally contribute to LEED Materials and Resources credit categories. 7 Standard Test Conditions(1000 W/m2 irradiance,AM 1.5,250 Q.NREL calibration Standard:SOMS current,LACCS FF and.Voltage. 8 Type 2 fire rating per UL1703:2013,Class C fire rating per Ut17032002. See www.sunpower.com/company for more reference information. For more details,see extended datasheet:,w.ww:sunpower,com/solar-resources. Specifications included in this datasheet are subject to change without notice. 02018 SunPower Corporation.All rights reserved.SUNPOWER,the SUNPOWER logo, S U N P O W E R® MAXPON and Invisilvount are trademarks or registered trademarks of SunPower Corporation. 1-800-SUNPOWER 527980 Rev A/LTR—US Sunpower.com IRONRIDGE XR100 Rail i See Description / Length Rail Section Properties Property Value Total Cross-Sectional Area 0.582 in' 66 Section Modulus (X-axis) 0.297 in' .46 Moment of Inertia (X-axis) 0.390 in - Moment of Inertia (Y-axis) 0.085 in` Torsional Constant _ 0.214 in Polar Moment of Inertia 0.126 in° 1.99 APPROVED MATERIALS: 2.44 6005-T6, 6005A-T61, 6105-T5, 6N01-T6 2.34 (34,000 PSI YIELD STRENGTH MINIMUM) .58 Clear Part Black Part Description/Length Material Weight Number Number XR-100-132A XR-100-132B XR100, Rail 132"(11 Feet) 7.50 lbs. XR-100-168A XR-100-1688 XR100, Rail 168"(14 Feet) 9.55 lbs. XR-100-204A XR-100-204B XR100, Rail 204"(17 Feet) Alluminumuminum 11.60 lbs. VIA V) Z U • FOO t PRODUCT GUIDE O Exploded Product View/B.O.M. - 1 Installation Instructions - 2 Cut Sheets - 3 Specifications -4 U .. C CL LU CL0 UOf Uj ' pL1Q F-- o0a EcoFasten Solar, QuikFoot— Product Guide Exploded Product View, Bill of Materials Materials Needed for Assembly 7 Item No. Description of Material/Part Quantity 1 QuikFoot Base Plate 1 6 2 Fastener(Length to be determined) 2 3 QuikFoot Flashing 1 4 EPDM Washer 1 0 5 L-102-3"Bracket*(other options available) 1 6 5/16"EPDM Bonded 18.8 SS Washer 1 �1 7 3/8"Stainless Steel Hex Nut 1 3 Required Tools w 2 o 1 r DAa CD C' 877-859-3947 EcoFasten Solar°All content protected under copyright.All rights reserved.10/09/14 1.1 EcoFasten Solar products are protected by the following U.S.Patents:8,151,522 132 8,153,700 132 8,181,398 132 8,166,713 B2 8.146.299 B2 8,209,914 B2 8.245,454 132 8,272,174 B2 8,225,557 B2 I QuikFoot— Product Guide Cut Sheets: QF-AL-Base 2X 0 .33in [8.38mm] O E E O °o r, `n �n OCO N LO N V 0 w O 1 .50in V [38.10mm] 3/8"-16 Stud a v ooa QF-M : 1 .5" QF-L : 1 .75" i a 877-859-3947 EcoFasten Solar®All content protected under copyright.All rights reserved.10/09/14 3.1 EcoFasten Solar products are protected by the following U.S.Patents:8,151,522 82 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2 QuikFoot— Product Guide Cut Sheets: QFL-812 R.38in [9.53mm] .032in [0.81 mm] O (� 12.00in [304.80mm] w 0 3.00in or�Q [76.20mm] d D wd .50in � 8.00in [ 12.70mm] [203.20mm] Jill 877-859-3947 EcoFasten Solar®All content protected under copyright.All rights reserved.10/09/14 3.2 EcoFasten Solar products are protected by the following U.S.Patents:8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2 QuikFoot— Product Guide Cut Sheets: Bracket Options-SCL-101-3 3/8" — A 46 SERRATIONS O LO r 1 7/8" - R1/16. 1/4" co 3/4' 1/16" ,j R.005 R.010 2X R.01 4;C- 30>- �� 60.000 + 006 `D 3/8 -.002 1/8.. C 0 7/8" X 820 DETAIL A SCALE 3:1 877-859-3947 EcoFasten Solar®All content protected under copyright.All rights reserved.10/09/14 3.7 EcoF isten Solar products are protected by the following U.S.Patents:8,151,522 132 8,153,700 132 8,181,398 B2 8,166,713 B2 8,146,299 132 8,209,914 132 8,245,454 B2 8,272,174 B2 8,225,557 B2 i QuikFoot- Product Guide Specifications PART 1 -GENERAL 1.1 SUMMARY 1.3 SUBMITTAL A. WORK INCLUDES A. Submit manufacturer's written specifications. B. Base plate is 6000 series aluminum with one 1. QuikFoot base plate attachment bracket that B. Submit standard product cut sheets. PEM Type Press-In Stud 18.8 SS. attaches directly to the roof deck. C. Submit installation instructions. C. Fasteners to be compatible with chosen roof 2 Provide appropriate bracket and fasteners D. Submit product specific load test data, showing application and meet specified pull out values for the roof system. ultimate and allowable load values specific to as shown in load test data. B. RELATED SECTIONS the roof deck specified for the project. D. Counter flashing is.032 gauge aluminum em- 1.Section 07600:Flashing and Sheet Metal bossed to accept shape of stainless steel base 2.Section 07500:Roofing 1.4 QUALITY ASSURANCE plate O 3.Division 1:Administrative and Procedural Installer to be experienced in the installation of Requirements specified roofing material for no less than 5 years in 2.3 FINISH 4.Division7:Thermal and Moisture Protection the area of the project. 1.2 SYSTEM DESCRIPTION A. Bracket is mill finish aluminum A. COMPONENTS: 1.5 DELIVERY/STORAGE/HANDLING B. Base flashing-Black-kynar painted 1. QuikFoot system consists of aluminum Inspect material upon delivery. Notify manufacturer bracket and base plate with(1)stainless steel within 24 hours of any missing or defective items. PART 3 - EXECUTION stud,(1)stainless steel nut,(1)EPDM washer Keep material dry,covered,and off the ground until and(1)bonded stainless steel and EPDM installed. 3.1 EXAMINATION washer. A. Substrate: Inspect structure on which brackets 2. Fasteners PART 2 - PRODUCTS are to be installed and verify that it will with- A.To be of metal compatible with QuikFoot stand bracket. 2.1 MANUFACTURER any additional loading that may be incurred. B. Fasteners should be selected for compat- EcoFasten Solar 289 Harrel Street,Morrisville,VT 05661 B. Notify General Contractor of an deficiencies O ibility with the roof deck. fY Y C.Fastener strength should exceed or be (877)859-3947 before installing EcoFasten Solar brackets. equal to that of the allowable load of the www.ecofastensolar.com V system. See test data at C. Verify that roofing material has been installed wstem, faste test data at 2.2 MATERIALS correctly prior to installing solar attachment AAttachment Bracket brackets. 3. Sealant(if required by roof manufacturer): A. to be roof manufacturer approved. 6000 Series Aluminum(choose one) Q 3.2 INSTALLATION 4. Aluminum counter-flashing 1.CP-SQ-Slotted A. Comply with architectural drawings and project Q )1,10 5. Aluminum attachment bracket 2. F-111-A 3.P-3-CSK engineer's recommendations for location of Dv4 B. DESIGN REQUIREMENTS: 4.SCL-101-3 system.Comply with Manufacturer's written in- stallation instructions for installation and layout. project engineer. 6.L-102-6" 2. Install a minimum of two fasteners per 7 Z-101 base plate. 8.Comp Slide 3. It is important to design new structures or 8.Custom assess existing structures to make sure that they can withstand retained loads. 877-859-3947 EcoFasten Solar,"All content protected under copyright.All rights reserved.10/09/14 4.1 + EcoFasten Solar products are protected by the following U.S.Patents:8,151.522 B2 8,153,700 B2 8.181,398 B2 8,166,713 B2 8,146.299 B2 8,209.914 B2 8.245 454 B2 8,272.174 B2 8,225,557 B2 Pioneer Valley Photovoltaics Cooperative POLICY DOCUMENT #9 Current version adopted by the Board of Directors on April 28, 2011 INSTALLATION CREW OPERATING POLICY This policy applies to all PV Squared employees in Massachusetts, but is particularly directed at those involved in the installation of solar electric and other renewable energy systems (licensed electrician, learner/apprentice electrician, licensed constructor supervisor, supervised carpenter and laborer). When engaged in this work as an employee of PV Squared on a PV Squared project site, activities of PV Squared employees are covered under the General Liability Insurance maintained by the Cooperative. It is the intent of this policy to provide clarity to installation situations where the applicable codes and regulations are unclear, ambiguous, or silent. It is possible that a municipal building or electrical inspector could interpret the codes and regulations in a manner that differs from what appears here. But this policy sets out, in writing, how the cooperative interprets legal work requirements and unclear details. It is an internal consensus working model, intended to be revised and improved from time to time. As a general matter, a city's or town's Building Commissioner is charged with enforcing the State Building Code, Plumbing and Gas Code, Electrical Code and Architectural Access Code. The commissioner addresses concerns about the safety, accessibility and security of construction of homes and businesses. The commissioner also enforces zoning bylaws. In accordance with Massachusetts General Law, employees of the cooperative who perform electrical tasks and activities must hold a Massachusetts journeymen's electrician license or be under the direct supervision of such licensed personnel. These tasks and activities include installing electrical wiring, conduits, apparatus, devices, fixtures or other appliances for carrying or using the electricity associated with Renewable Energy Generators (electrically active solar photovoltaic modules, wind turbine-generators, hydroelectric generators, etc.). In no circumstances shall the Massachusetts licensed journeymen have more than one learner or apprentice working with him/her or under his/her supervision. Mounting structures come in a variety of configurations and have differing functional and physical characteristics. A structural component or assembly becomes associated with electrical work as the Renewable Energy Generator is electrically bonded to the mounting structure. Unless otherwise noted in M.G.L. c.143 553 through 5560 inclusive, all structural work defined as follows shall not be required to be performed by a Massachusetts licensed journeymen electrician: • Structural improvements • Elements of a Renewable Energy Generator's support structure that fall under a building permit (e.g., assembly of top-of-pole mounting structure on steel pole with concrete foundation prior to execution of any required electrical bonding of the support structure and associated renewable energy generator (solar electric module) to the support structure Policy # 9 Installation Crew Operating Policy 1 � Pioneer Valley PhotoVoltaics Cooperative POLICY DOCUMENT #9 Current version adopted by the Board of Directors on April 28, 2011 • Roof-top mounting support structures including but not limited to posts, stand-offs, flashings, feet, and mounting rails • Operation of heavy equipment involved in moving, hoisting, digging and other tasks • Earth work, excavation and concrete work • Manual labor involved in moving loading and unloading of equipment • Moving, hoisting, and attaching an electrically bonded panel assembly (defined as one or more assembled and electrically bonded solar electric modules) to an existing structural support designed to host the panel assembly. Note however that construction of a panel assembly is an electrical task due to the required electrical bonding activities. Repair and Servicing of Installed Equipment Repair or replacement of an electrically bonded and/or energized renewable energy generator (e.g., installed solar electric panel) will be performed by a licensed electrician or properly supervised learner or apprentice working with the licensed electrician. Replacement of an installed inverter must be performed by a licensed electrician or properly supervised learner or apprentice working with the licensed electrician, if the work requires removal of AC and/or DC conduit and associated wiring that originates outside of the installed inverter (e.g., removal of external AC conduit and wiring between the inverter and point of interconnection with the on-site electrical service). Note that this activity may require a wiring permit in some local jurisdictions. This requirement also applies to the servicing of an installed inverter that involves replacement or repair of components and wiring internal to the pre-manufacturer inverter (i.e., factory installed components that were originally shipped with the inverter) even though such activity may not require a wiring permit. Replacement of an installed inverter may also be performed by a qualified technician who may or may not be a licensed electrician or properly supervised learner or apprentice working with a licensed electrician if the inverter is of a "plug and play" design. Such a qualified technician can also performed other tasks that include installation and servicing inverter-based performance monitoring systems (e.g., replacing internal communication cards, making "plug and play" ethernet connections, etc.), assuming these activities do not require creation of a new AC power source circuit to operate the communication system(s). Policy # 9 Installation Crew Operating Policy . . Non Electrical Work at a typical PV Squared installation: • All Material Handling tasks o Module prep and moving o Ladder lift set up o Ladder set up o Trash/recycling removal and sorting • Structural Improvements o All carpentry work • Roof Mount Array o Fall protection anchor setup and removal o Layout and mounting bases o Racking up to but not including"bonding/grounding related activities" o Leveling of racking o Sealing seams/patching roofing/additional flashing • Ground mount array o Site work, earth moving o Trenching/digging o Construction of racking up to but not including "bonding/grounding related activities" • Conduit run o Making holes in structure o Fire blocking, sealing penetrations o Stickers • Power Board o Build wall, hang plywood o Stickers • Interconnection o Stickers • Monitoring o Wifi options o Any"plug and play"devices o Programming of monitoring devices o Computer based activities • Installation completion o Final building inspections o Install pictures-See checklist o Update one line and roof drawings to reflect as built o Completion checklist o Notes for others o COC left onsite • Misc o Truck Organizing o Material List, ordering o Daily check-in o Customer interaction and training activities SCIU4 J RF a PV Squared Solar www.pvsquared.coop Phone:413-772-8788 Fax:413-772-8668 311 Wells St.,Ste.8 Greenfield,MA 01301 0R M. 00 MA Elec. Lic.A13764 S MA HIC 140077 Dear Town Inspections Officials, Please see our enclosed applications to permit a Solar Photovoltaic System in your jurisdiction. As you are likely aware, PV Squared is a worker-owned-cooperative B-Corp, employing 40+ people in Greenfield. We have installed thousands of PV Systems out of our Greenfield, MA Headquarters since 2002. PV Squared is committed to complying with all Commonwealth laws and regulations. Our worksite guidelines are created with the intention of exceeding all safety, electrical, and building requirements as defined by their respective jurisdictional entities. This includes the work of people from multiple disciplines, including electrical engineering, structural engineering, civil engineering, electricians, construction supervisors, roofers, and their associated helpers. We are a company that values training and education. We make certain that every individual is qualified for the roles and responsibilities that they assume. It is our policy to pay for the employees travel and training time and cost of the education, including CSL and Journeyman and Master Electrician classes. As an electrical contractor we are furthermore guided by the January 30, 2009 Massachusetts Board of State Examiners of Electricians (BSEE)judgements, and rulings that have followed. We pay strict adherence to these mandates and all electrical work is conducted by an electrician and an electrician's apprentice in a 1:1 ratio. We also understand that non-electrical tasks associated with a Solar installation can be completed by non-electrical workers, such as CSLs and others. I have attached our installation policy for your review, as well as a list of example non-electrical tasks. Should you have any questions or concerns regarding this policy or delineation of work, please let us know. We are a learning organization that is always trying to improve on what we do. Respectfully, Adam Thurrell Operations Manager New England Construction Engineering, PLC 436 Campbell Street (NECE) Structural Construction Solutions White River Junction,VT 05001 Jonathan Rugg, P.E. 603-903-9798 j.rugg@NewEnglandConstrUctionEngineering.com August 5, 2019 Ms. Jeannine Haendiges Pioneer Valley PhotoVoltaics Cooperative, Inc. 311 Wells Street, Suite B Greenfield, MA 01301 Re: Cole Residence#2, Leverett, MA PV Squared Project No. 12285 NECE Project No. 19-001 T63 Dear Ms. Haendiges, At your request New England Construction Engineering, PLC (NECE) has reviewed the information that Pioneer Valley PhotoVoltaics Cooperative, Inc. (PV Squared) provided on the roof supporting structure of the Cole residence, at 599 Coles Meadow Road, in Northampton, MA. The purpose of this review was to provide an opinion regarding the structure's ability to support a proposed rooftop mounted Photovoltaic (PV) array.The information that you provided is attached to this letter for reference. You are proposing to mount PV panels on the house roof. The house is a two-story residence with a hip roof with a walkout basement. The second-floor roof houses an existing PV array, and you are proposing to mount an additional array on a one-story extension of the house. The section of house where you propose this second array measures approximately 18'x26'. It has a hip roof with a 40-degree pitch.The roof is framed with 2x10 rafters at 16" O.C. These rafters span approximately 13' on the horizontal. The roof has structural wood panel sheathing and asphalt shingles. NECE's analysis considered controlling gravity loads (dead load and snow load). Lateral loads (wind and seismic) are excluded from this review. Conclusion: Based on the information that you provided, the roof will support both the design snow load, and the additional dead load of your proposed PV Array. I base this opinion on the following assumptions. I assume that, owing to their smooth surface, the PV panels will shed snow more readily than the existing asphalt shingles. I further assume that that the PV panels will be installed parallel to the roof, eliminating any additional wind load.The ground snow load (Pg) for Northampton is 40 psf. According to information that you provided, the proposed PV panels weigh approximately 2.3psf. New England Construction Engineering, PLC PV Squared—Cole Residence#2 Jonathan Rugg, P.E. Northampton, MA Page 2 of 2 In summary, based on the information that you provided, and subject assumptions discussed above, in my opinion, the roof will support the proposed array. Thank you for the opportunity to assist with this project. If we can be of further assistance, please contact Jonathan Rugg at NECE. SN OF 144SS9c' Sincerely, � JONATHAN A � C> RUGG No. 51982 /�Iathan Rugg, P.E. STE � New England Construction Engineering, PLC. S�NAI � 5 209 Attachments: -Building information