17A-013 (2) Ross Solar A ConEdison Solutions company 38 Beaver Brook Road EXISTING DANBURY,CT 06810 UTILITY SERVICE www.rosssolar.com ACC#03647-00014 3W,120/240V PH:203.512.4500 METER#80610309 SINGLE PHASE FAX: 866-271-3016 w 0 Lu Lu Description Notes Module Specifications Inverter DC Input Details 5.94 kW DC System System Size Model LG330N1C-A5 `Calculated @-20 F Record LOW M w M U 1 LG330N 1 C-A5 18 Solar Panels Peak Power 330 W Label Rated Voltage (Vmp) 33.7 V LG330N1C-A5 Spec 1 String of 18 Values z O o 2 SE 5000H-US W/RGM 1 SolarEdge Inverter w/ Rated Current (Imp) 9.83 A Vmp 33.7 V 380 V 380 V a o P370 optimizers (x18) Open Circuit vonage (Voc 2 - 41.OV Imp 9.83A 13.5A 14A 3 Square D DU222RB or 60A Non Fused AC Disc Voc at-20'F 46.42 V P BASEMENT Z � o Short Circuit Current (Is 10.49 A O 0 equivalent Voc' 46.42 V 480 V 480 V N_ w 5 Smart Meter Production Monitor > 2 Isc 10.49 A 15 A 15A - X ® U 6 Main Service Panel w o � a rn EXISTING MURRAY INTERNAL 125A,240V CF 2P SERVICE PANEL o R a n m Y F 8 LL m Q n O ATTIC/ROOF I OUTSIDE O w r 30A,2P L Q� LINE Z r�rrt�t ROOFTOP I VERIFY PRESENCE OF J PV ARRAY (2) #10 PV WIRE CU (POS,NEG) - _ SECOND GROUND. l`__ 0- ` (1) #10 CU (GRD) I MA SMART METER ADD IF NECESSARY, (1' NEMA 3R, NEMA 3R MIBANK L1 L2 J J `V BOND TO EXISTING- Sl (1$) 60A,240V,NON-FUSED U2272-RL-5T9-BL MINIMUM 6' O U ! , SE500TE US 60 DISCONNECT 125A,600V RATED G (3)#6 CU THWN-2 (LI.L2,N) SEPARATION O (1)#to CU THWN-2 (G) F-- (1) U (n o00 = (1) 1"EMT C 20.83A,240V LOAD = Lu +�-+ Q) C) O MAX.OPER. I� JI 21X,OPE240V GENERAL ELECTRICAL NOTES: F Lu JB METAL 6X6X40 1. ALL INSTALLATION TO CONFORM WITH NEC 2017 U F- IN THE ATTIC71 (2) 2. MODULES SHALL BE UNGROUNDED. Z U 0 MID+END CLAMPS ARE UL LISTED FOR 3. MODULES FRAMES SHALL BE GROUNDED TO FRAMES I INTEGRAL BONDING OF (3) #6 CU THWN-2 (L1,L2,N) USING INTEGRAL GROUNDING K 0 Z PANELS TO RAILS; (2) #10 CU THWN-2 (L1,12) (t) #10 CU THWN-2 (G) 4. RAILING SHALL BE GROUNDED USING GROUNDING LUGS. RAIL SPLICES ARE UL LISTED FOR BONDING RAIL (2) #t0 CU THWN-2 (N,G) (t) t"EMT C 0 0_ (7) 1"EMT C 5. BONDING BUSHING SHALL BE INSTALLED ON BOTH ENDS SPLICES; CU THWN-2(POS.NEG) OF EQUIPMENTS CARRYING GEC,REFER TO NEC 250.97. DESIGNED BY: RAILS ARE BONDED TOGETHER WITH#8 CU CU (GRD) 6. VERIFY PRESENCE OF 2ND GROUND,ADD IF NECESSARY WIRE UL LISTED BONDING CLAMPS; (1) 1"EMT C BB OND TO EXISTING-MINIMUM COMPLIANT Andrei Belov A#10 CU WIRE IS RUN IN THE CONDUIT WITH THE 7. VERIFY AND ENSURE CODE COMPLIANT BONDING OF PANEL DC WIRING TO THE BONDING CONNECTOR I WATER MAIN/METER DRAWN BY: TPC ON THE DC DISCONNECT OF THE INVERTER. USE TOTAL APPROVED BY: OF 2ILSCO I Andy Mayshar CONNECTORS DATE 02/06/2019 SHEET NUMBER 1 ELECTRICAL ONE LINE DIAGRAM E- 1 E-1 SHEET 1 OF 1 Ross row, Solar A ConEdison Solutions company CONED SOLUTIONS 38 Beaver Brook Road DANBURY,CT 06810 S ,i.1 S PH 203.512.4500 71 Q 0 b - w w vN z Y' ✓ 's 1 z S I UJl W O 0 I O W Lii I N r II m I 1 I N I o ,� � � U) W W S I H0 clQ� 4 V x M w � a) LLti LEGEND Z� & z Up ROOF ACCESS AREA (36" WIDE) ,,, ' Z o n a DESIGNED BY: ACCESS ROOF I ,; DRAWN BY: LFC APPROVED BY: RIDGE VENTILATION (18" WIDE) -tis - } a DATE 05/07/2019 RIDGE ACCESS (36" WIDE) _ • SHEET NUMBER SOLAR ARRAY FA-L SHEET 10F 1